LMP-MIB

File: LMP-MIB.mib (113206 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
IF-MIB INET-ADDRESS-MIB TE-LINK-STD-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
transmission Unsigned32 Counter32
TimeTicks MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP TEXTUAL-CONVENTION TruthValue
RowStatus StorageType TimeStamp
InterfaceIndexOrZero ifIndex InetAddressType
InetAddress teLinkRemoteIpAddr teLinkIncomingIfId
TeLinkEncodingType

Defined Types

LmpInterval  
The interval delay, in milliseconds.
TEXTUAL-CONVENTION    
  Unsigned32 1..65535  

LmpRetransmitInterval  
The retransmission interval delay in milliseconds.
TEXTUAL-CONVENTION    
  Unsigned32 1..4294967295  

LmpNodeId  
Represents a Node ID in network byte order. Node ID is an address of type IPv4.
TEXTUAL-CONVENTION    
  OCTET STRING Size(4)  

LmpNbrEntry  
SEQUENCE    
  lmpNbrNodeId LmpNodeId
  lmpNbrRetransmitInterval LmpRetransmitInterval
  lmpNbrRetryLimit Unsigned32
  lmpNbrRetransmitDelta Unsigned32
  lmpNbrAdminStatus INTEGER
  lmpNbrOperStatus INTEGER
  lmpNbrRowStatus RowStatus
  lmpNbrStorageType StorageType

LmpControlChannelEntry  
SEQUENCE    
  lmpCcId Unsigned32
  lmpCcUnderlyingIfIndex InterfaceIndexOrZero
  lmpCcIsIf TruthValue
  lmpCcNbrNodeId LmpNodeId
  lmpCcRemoteId Unsigned32
  lmpCcRemoteAddressType InetAddressType
  lmpCcRemoteIpAddr InetAddress
  lmpCcSetupRole INTEGER
  lmpCcAuthentication TruthValue
  lmpCcHelloInterval LmpInterval
  lmpCcHelloIntervalMin LmpInterval
  lmpCcHelloIntervalMax LmpInterval
  lmpCcHelloIntervalNegotiated LmpInterval
  lmpCcHelloDeadInterval LmpInterval
  lmpCcHelloDeadIntervalMin LmpInterval
  lmpCcHelloDeadIntervalMax LmpInterval
  lmpCcHelloDeadIntervalNegotiated LmpInterval
  lmpCcLastChange TimeTicks
  lmpCcAdminStatus INTEGER
  lmpCcOperStatus INTEGER
  lmpCcRowStatus RowStatus
  lmpCcStorageType StorageType

LmpControlChannelPerfEntry  
SEQUENCE    
  lmpCcInOctets Counter32
  lmpCcInDiscards Counter32
  lmpCcInErrors Counter32
  lmpCcOutOctets Counter32
  lmpCcOutDiscards Counter32
  lmpCcOutErrors Counter32
  lmpCcConfigReceived Counter32
  lmpCcConfigSent Counter32
  lmpCcConfigRetransmit Counter32
  lmpCcConfigAckReceived Counter32
  lmpCcConfigAckSent Counter32
  lmpCcConfigNackReceived Counter32
  lmpCcConfigNackSent Counter32
  lmpCcHelloReceived Counter32
  lmpCcHelloSent Counter32
  lmpCcBeginVerifyReceived Counter32
  lmpCcBeginVerifySent Counter32
  lmpCcBeginVerifyRetransmit Counter32
  lmpCcBeginVerifyAckReceived Counter32
  lmpCcBeginVerifyAckSent Counter32
  lmpCcBeginVerifyNackReceived Counter32
  lmpCcBeginVerifyNackSent Counter32
  lmpCcEndVerifyReceived Counter32
  lmpCcEndVerifySent Counter32
  lmpCcEndVerifyRetransmit Counter32
  lmpCcEndVerifyAckReceived Counter32
  lmpCcEndVerifyAckSent Counter32
  lmpCcTestStatusSuccessReceived Counter32
  lmpCcTestStatusSuccessSent Counter32
  lmpCcTestStatusSuccessRetransmit Counter32
  lmpCcTestStatusFailureReceived Counter32
  lmpCcTestStatusFailureSent Counter32
  lmpCcTestStatusFailureRetransmit Counter32
  lmpCcTestStatusAckReceived Counter32
  lmpCcTestStatusAckSent Counter32
  lmpCcLinkSummaryReceived Counter32
  lmpCcLinkSummarySent Counter32
  lmpCcLinkSummaryRetransmit Counter32
  lmpCcLinkSummaryAckReceived Counter32
  lmpCcLinkSummaryAckSent Counter32
  lmpCcLinkSummaryNackReceived Counter32
  lmpCcLinkSummaryNackSent Counter32
  lmpCcChannelStatusReceived Counter32
  lmpCcChannelStatusSent Counter32
  lmpCcChannelStatusRetransmit Counter32
  lmpCcChannelStatusAckReceived Counter32
  lmpCcChannelStatusAckSent Counter32
  lmpCcChannelStatusReqReceived Counter32
  lmpCcChannelStatusReqSent Counter32
  lmpCcChannelStatusReqRetransmit Counter32
  lmpCcChannelStatusRspReceived Counter32
  lmpCcChannelStatusRspSent Counter32
  lmpCcCounterDiscontinuityTime TimeStamp

LmpTeLinkEntry  
SEQUENCE    
  lmpTeLinkNbrRemoteNodeId LmpNodeId
  lmpTeLinkVerification TruthValue
  lmpTeLinkFaultManagement TruthValue
  lmpTeLinkDwdm TruthValue
  lmpTeLinkOperStatus INTEGER
  lmpTeLinkRowStatus RowStatus
  lmpTeLinkStorageType StorageType

LmpLinkVerificationEntry  
SEQUENCE    
  lmpLinkVerifyInterval LmpInterval
  lmpLinkVerifyDeadInterval LmpInterval
  lmpLinkVerifyTransportMechanism BITS
  lmpLinkVerifyAllLinks TruthValue
  lmpLinkVerifyTransmissionRate Unsigned32
  lmpLinkVerifyWavelength Unsigned32
  lmpLinkVerifyRowStatus RowStatus
  lmpLinkVerifyStorageType StorageType

LmpTeLinkPerfEntry  
SEQUENCE    
  lmpTeInOctets Counter32
  lmpTeOutOctets Counter32
  lmpTeBeginVerifyReceived Counter32
  lmpTeBeginVerifySent Counter32
  lmpTeBeginVerifyRetransmit Counter32
  lmpTeBeginVerifyAckReceived Counter32
  lmpTeBeginVerifyAckSent Counter32
  lmpTeBeginVerifyNackReceived Counter32
  lmpTeBeginVerifyNackSent Counter32
  lmpTeEndVerifyReceived Counter32
  lmpTeEndVerifySent Counter32
  lmpTeEndVerifyRetransmit Counter32
  lmpTeEndVerifyAckReceived Counter32
  lmpTeEndVerifyAckSent Counter32
  lmpTeTestStatusSuccessReceived Counter32
  lmpTeTestStatusSuccessSent Counter32
  lmpTeTestStatusSuccessRetransmit Counter32
  lmpTeTestStatusFailureReceived Counter32
  lmpTeTestStatusFailureSent Counter32
  lmpTeTestStatusFailureRetransmit Counter32
  lmpTeTestStatusAckReceived Counter32
  lmpTeTestStatusAckSent Counter32
  lmpTeLinkSummaryReceived Counter32
  lmpTeLinkSummarySent Counter32
  lmpTeLinkSummaryRetransmit Counter32
  lmpTeLinkSummaryAckReceived Counter32
  lmpTeLinkSummaryAckSent Counter32
  lmpTeLinkSummaryNackReceived Counter32
  lmpTeLinkSummaryNackSent Counter32
  lmpTeChannelStatusReceived Counter32
  lmpTeChannelStatusSent Counter32
  lmpTeChannelStatusRetransmit Counter32
  lmpTeChannelStatusAckReceived Counter32
  lmpTeChannelStatusAckSent Counter32
  lmpTeChannelStatusReqReceived Counter32
  lmpTeChannelStatusReqSent Counter32
  lmpTeChannelStatusReqRetransmit Counter32
  lmpTeChannelStatusRspReceived Counter32
  lmpTeChannelStatusRspSent Counter32
  lmpTeCounterDiscontinuityTime TimeStamp

LmpDataLinkEntry  
SEQUENCE    
  lmpDataLinkType INTEGER
  lmpDataLinkAddressType InetAddressType
  lmpDataLinkIpAddr InetAddress
  lmpDataLinkRemoteIpAddress InetAddress
  lmpDataLinkRemoteIfId InterfaceIndexOrZero
  lmpDataLinkEncodingType TeLinkEncodingType
  lmpDataLinkActiveOperStatus INTEGER
  lmpDataLinkPassiveOperStatus INTEGER
  lmpDataLinkRowStatus RowStatus
  lmpDataLinkStorageType StorageType

LmpDataLinkPerfEntry  
SEQUENCE    
  lmpDataLinkTestReceived Counter32
  lmpDataLinkTestSent Counter32
  lmpDataLinkActiveTestSuccess Counter32
  lmpDataLinkActiveTestFailure Counter32
  lmpDataLinkPassiveTestSuccess Counter32
  lmpDataLinkPassiveTestFailure Counter32
  lmpDataLinkDiscontinuityTime TimeStamp

Defined Values

lmpMIB 1.3.6.1.2.1.10.227
Copyright (C) 2006 The Internet Society. This version of the MIB module is part of RFC 4631; see the RFC itself for full legal notices. This MIB module contains managed object definitions for the Link Management Protocol (LMP) as defined in 'Link Management Protocol'.
MODULE-IDENTITY    

lmpNotifications 1.3.6.1.2.1.10.227.0
OBJECT IDENTIFIER    

lmpObjects 1.3.6.1.2.1.10.227.1
OBJECT IDENTIFIER    

lmpConformance 1.3.6.1.2.1.10.227.2
OBJECT IDENTIFIER    

lmpAdminStatus 1.3.6.1.2.1.10.227.1.1
The desired operational status of LMP on the node. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2)  

lmpOperStatus 1.3.6.1.2.1.10.227.1.2
The actual operational status of LMP on the node.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

lmpNbrTable 1.3.6.1.2.1.10.227.1.3
This table specifies the neighbor node(s) to which control channels may be established.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LmpNbrEntry

lmpNbrEntry 1.3.6.1.2.1.10.227.1.3.1
An entry in this table is created by a LMP-enabled device for every pair of nodes that can establish control channels.
Status: current Access: not-accessible
OBJECT-TYPE    
  LmpNbrEntry  

lmpNbrNodeId 1.3.6.1.2.1.10.227.1.3.1.1
This is a unique index for an entry in the LmpNbrTable. This value represents the remote Node ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  LmpNodeId  

lmpNbrRetransmitInterval 1.3.6.1.2.1.10.227.1.3.1.2
This object specifies the initial retransmission interval that is used for the retransmission of messages that require acknowledgement. This object, along with lmpNbrRetryLimit, is used to implement the congestion-handling mechanism defined in Section 10 of the Link Management Protocol specification, which is based on RFC 2914.
Status: current Access: read-create
OBJECT-TYPE    
  LmpRetransmitInterval  

lmpNbrRetryLimit 1.3.6.1.2.1.10.227.1.3.1.3
This object specifies the maximum number of times a message is transmitted without being acknowledged. A value of 0 is used to indicate that a node should never stop retransmission. This object, along with lmpNbrRetransmitInterval, is used to implement the congestion-handling mechanism as defined in Section 10 of the Link Management Protocol specification, which is based on RFC 2914.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

lmpNbrRetransmitDelta 1.3.6.1.2.1.10.227.1.3.1.4
This object governs the speed with which the sender increases the retransmission interval, as explained in Section 10 of the Link Management Protocol specification, which is based on RFC 2914. This value is a power used to express the exponential backoff. The ratio of two successive retransmission intervals is (1 + Delta).
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

lmpNbrAdminStatus 1.3.6.1.2.1.10.227.1.3.1.5
The desired operational status of LMP to this remote node.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(1), down(2)  

lmpNbrOperStatus 1.3.6.1.2.1.10.227.1.3.1.6
The actual operational status of LMP to this remote node.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

lmpNbrRowStatus 1.3.6.1.2.1.10.227.1.3.1.7
This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). All read-create objects must have valid and consistent values before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

lmpNbrStorageType 1.3.6.1.2.1.10.227.1.3.1.8
The storage type for this conceptual row in the lmpNbrTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

lmpCcHelloIntervalDefault 1.3.6.1.2.1.10.227.1.4
This object specifies the default value for the HelloInterval parameter used in the Hello protocol keep-alive phase. It indicates how frequently LMP Hello messages will be sent. It is used as the default value for lmpCcHelloInterval. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloIntervalDefaultMin 1.3.6.1.2.1.10.227.1.5
This object specifies the default minimum value for the HelloInterval parameter. It is used as a default value for lmpCcHelloIntervalMin. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloIntervalDefaultMax 1.3.6.1.2.1.10.227.1.6
This object specifies the default maximum value for the HelloInterval parameter. It is used as a default value for lmpCcHelloIntervalMax. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloDeadIntervalDefault 1.3.6.1.2.1.10.227.1.7
This object specifies the default HelloDeadInterval parameter to use in the Hello protocol keep-alive phase. It indicates how long a device should wait before declaring the control channel dead. The HelloDeadInterval parameter should be at least three times the value of HelloInterval. It is used as a default value for lmpCcHelloDeadInterval. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloDeadIntervalDefaultMin 1.3.6.1.2.1.10.227.1.8
This object specifies the default minimum value for the HelloDeadInterval parameter. It is used as a default value for lmpCcHelloDeadIntervalMin. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloDeadIntervalDefaultMax 1.3.6.1.2.1.10.227.1.9
This object specifies the default maximum value for the HelloDeadInterval parameter. It is used as a default value for lmpCcHelloDeadIntervalMax. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  LmpInterval  

lmpControlChannelTable 1.3.6.1.2.1.10.227.1.10
This table specifies LMP control channel information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LmpControlChannelEntry

lmpControlChannelEntry 1.3.6.1.2.1.10.227.1.10.1
An entry in this table is created by an LMP-enabled device for every control channel. Whenever a new entry is created with lmpCcIsIf set to true(1), a corresponding entry is created in ifTable as well (see RFC 2863).
Status: current Access: not-accessible
OBJECT-TYPE    
  LmpControlChannelEntry  

lmpCcId 1.3.6.1.2.1.10.227.1.10.1.1
This value represents the local control channel identifier. The control channel identifier is a non-zero 32-bit number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4294967295  

lmpCcUnderlyingIfIndex 1.3.6.1.2.1.10.227.1.10.1.2
If lmpCcIsIf is set to true(1), this object carries the index into the ifTable of the entry that represents the LMP interface over which LMP will transmit its traffic. If this object is set to zero but lmpCcIsIf is set to true(1), the control channel is not currently associated with any underlying interface, and the control channel's operational status must not be up(1); nor should the control channel forward or receive traffic. If lmpCcIsIf is set to false(2), this object should be set to zero and ignored.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

lmpCcIsIf 1.3.6.1.2.1.10.227.1.10.1.3
In implementations where the control channels are modeled as interfaces, the value of this object is true(1), and this control channel is represented by an interface in the interfaces group table as indicated by the value of lmpCcUnderlyingIfIndex. If control channels are not modeled as interfaces, the value of this object is false(2), and there is no corresponding interface for this control channel in the interfaces group table; the value of lmpCcUnderlyingIfIndex should be ignored.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

lmpCcNbrNodeId 1.3.6.1.2.1.10.227.1.10.1.4
This is the Node ID of the control channel remote node. This value either is configured or gets created by the node when a Config message is received or when an outgoing Config message is acknowledged by the remote node.
Status: current Access: read-create
OBJECT-TYPE    
  LmpNodeId  

lmpCcRemoteId 1.3.6.1.2.1.10.227.1.10.1.5
This value represents the remote control channel identifier (32-bit number). It is determined during the negotiation phase. A value of zero means that the remote control channel identifier has not yet been learned.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

lmpCcRemoteAddressType 1.3.6.1.2.1.10.227.1.10.1.6
This value represents the remote control channel IP address type. In point-to-point configuration, this value can be set to unknown(0).
Status: current Access: read-create
OBJECT-TYPE    
  InetAddressType  

lmpCcRemoteIpAddr 1.3.6.1.2.1.10.227.1.10.1.7
This value represents the remote control channel Internet address for numbered control channel. The type of this address is determined by lmpCcRemoteAddressType. The control channel must be numbered on non-point-to-point configuration. For point-to-point configuration, the remote control channel address can be of type unknown, in which case this object must be a zero-length string. The lmpCcRemoteId object then identifies the unnumbered address.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddress  

lmpCcSetupRole 1.3.6.1.2.1.10.227.1.10.1.8
The role that this node should take during establishment of this control channel. An active node will initiate establishment. A passive node will wait for the remote node to initiate. A pair of nodes that both take the passive role will never establish communications.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER active(1), passive(2)  

lmpCcAuthentication 1.3.6.1.2.1.10.227.1.10.1.9
This object indicates whether the control channel must use authentication.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

lmpCcHelloInterval 1.3.6.1.2.1.10.227.1.10.1.10
This object specifies the value of the HelloInterval parameter. The default value for this object should be set to lmpCcHelloIntervalDefault.
Status: current Access: read-create
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloIntervalMin 1.3.6.1.2.1.10.227.1.10.1.11
This object specifies the minimum value for the HelloInterval parameter. The default value for this object should be set to lmpCcHelloIntervalMinDefault.
Status: current Access: read-create
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloIntervalMax 1.3.6.1.2.1.10.227.1.10.1.12
This object specifies the maximum value for the HelloInterval parameter. The default value for this object should be set to lmpCcHelloIntervalMaxDefault.
Status: current Access: read-create
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloIntervalNegotiated 1.3.6.1.2.1.10.227.1.10.1.13
Once the control channel is active, this object represents the negotiated HelloInterval value.
Status: current Access: read-only
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloDeadInterval 1.3.6.1.2.1.10.227.1.10.1.14
This object specifies the value of the HelloDeadInterval parameter. The default value for this object should be set to lmpCcHelloDeadIntervalDefault.
Status: current Access: read-create
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloDeadIntervalMin 1.3.6.1.2.1.10.227.1.10.1.15
This object specifies the minimum value for the HelloDeadInterval parameter. The default value for this object should be set to lmpCcHelloDeadIntervalMinDefault.
Status: current Access: read-create
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloDeadIntervalMax 1.3.6.1.2.1.10.227.1.10.1.16
This object specifies the maximum value for the HelloDeadInterval parameter. The default value for this object should be set to lmpCcHelloIntervalMaxDefault.
Status: current Access: read-create
OBJECT-TYPE    
  LmpInterval  

lmpCcHelloDeadIntervalNegotiated 1.3.6.1.2.1.10.227.1.10.1.17
Once the control channel is active, this object represents the negotiated HelloDeadInterval value.
Status: current Access: read-only
OBJECT-TYPE    
  LmpInterval  

lmpCcLastChange 1.3.6.1.2.1.10.227.1.10.1.18
The value of sysUpTime at the time the control channel entered its current operational state. If the current state was entered prior to the last re-initialization of the local network management subsystem, then this object contains a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

lmpCcAdminStatus 1.3.6.1.2.1.10.227.1.10.1.19
The desired operational status of this control channel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(1), down(2)  

lmpCcOperStatus 1.3.6.1.2.1.10.227.1.10.1.20
The actual operational status of this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), configSnd(3), configRcv(4), active(5), goingDown(6)  

lmpCcRowStatus 1.3.6.1.2.1.10.227.1.10.1.21
This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). All read-create objects must have valid and consistent values before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

lmpCcStorageType 1.3.6.1.2.1.10.227.1.10.1.22
The storage type for this conceptual row in the lmpControlChannelTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

lmpControlChannelPerfTable 1.3.6.1.2.1.10.227.1.11
This table specifies LMP control channel performance counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LmpControlChannelPerfEntry

lmpControlChannelPerfEntry 1.3.6.1.2.1.10.227.1.11.1
An entry in this table is created by a LMP-enabled device for every control channel. lmpCcCounterDiscontinuityTime is used to indicate potential discontinuity for all counter objects in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  LmpControlChannelPerfEntry  

lmpCcInOctets 1.3.6.1.2.1.10.227.1.11.1.1
The total number of LMP message octets received on the control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcInDiscards 1.3.6.1.2.1.10.227.1.11.1.2
The number of inbound packets that were chosen to be discarded even though no errors had been detected. One possible reason for discarding such a packet could be to free up buffer space.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcInErrors 1.3.6.1.2.1.10.227.1.11.1.3
The number of inbound packets that contained errors preventing them from being processed by LMP.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcOutOctets 1.3.6.1.2.1.10.227.1.11.1.4
The total number of LMP message octets transmitted out of the control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcOutDiscards 1.3.6.1.2.1.10.227.1.11.1.5
The number of outbound packets that were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcOutErrors 1.3.6.1.2.1.10.227.1.11.1.6
The number of outbound packets that could not be transmitted because of errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcConfigReceived 1.3.6.1.2.1.10.227.1.11.1.7
This object counts the number of Config messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcConfigSent 1.3.6.1.2.1.10.227.1.11.1.8
This object counts the number of Config messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcConfigRetransmit 1.3.6.1.2.1.10.227.1.11.1.9
This object counts the number of Config messages that have been retransmitted over this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcConfigAckReceived 1.3.6.1.2.1.10.227.1.11.1.10
This object counts the number of ConfigAck messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcConfigAckSent 1.3.6.1.2.1.10.227.1.11.1.11
This object counts the number of ConfigAck messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcConfigNackReceived 1.3.6.1.2.1.10.227.1.11.1.12
This object counts the number of ConfigNack messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcConfigNackSent 1.3.6.1.2.1.10.227.1.11.1.13
This object counts the number of ConfigNack messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcHelloReceived 1.3.6.1.2.1.10.227.1.11.1.14
This object counts the number of Hello messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcHelloSent 1.3.6.1.2.1.10.227.1.11.1.15
This object counts the number of Hello messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcBeginVerifyReceived 1.3.6.1.2.1.10.227.1.11.1.16
This object counts the number of BeginVerify messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcBeginVerifySent 1.3.6.1.2.1.10.227.1.11.1.17
This object counts the number of BeginVerify messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcBeginVerifyRetransmit 1.3.6.1.2.1.10.227.1.11.1.18
This object counts the number of BeginVerify messages that have been retransmitted over this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcBeginVerifyAckReceived 1.3.6.1.2.1.10.227.1.11.1.19
This object counts the number of BeginVerifyAck messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcBeginVerifyAckSent 1.3.6.1.2.1.10.227.1.11.1.20
This object counts the number of BeginVerifyAck messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcBeginVerifyNackReceived 1.3.6.1.2.1.10.227.1.11.1.21
This object counts the number of BeginVerifyNack messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcBeginVerifyNackSent 1.3.6.1.2.1.10.227.1.11.1.22
This object counts the number of BeginVerifyNack messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcEndVerifyReceived 1.3.6.1.2.1.10.227.1.11.1.23
This object counts the number of EndVerify messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcEndVerifySent 1.3.6.1.2.1.10.227.1.11.1.24
This object counts the number of EndVerify messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcEndVerifyRetransmit 1.3.6.1.2.1.10.227.1.11.1.25
This object counts the number of EndVerify messages that have been retransmitted over this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcEndVerifyAckReceived 1.3.6.1.2.1.10.227.1.11.1.26
This object counts the number of EndVerifyAck messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcEndVerifyAckSent 1.3.6.1.2.1.10.227.1.11.1.27
This object counts the number of EndVerifyAck messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcTestStatusSuccessReceived 1.3.6.1.2.1.10.227.1.11.1.28
This object counts the number of TestStatusSuccess messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcTestStatusSuccessSent 1.3.6.1.2.1.10.227.1.11.1.29
This object counts the number of TestStatusSuccess messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcTestStatusSuccessRetransmit 1.3.6.1.2.1.10.227.1.11.1.30
This object counts the number of TestStatusSuccess messages that have been retransmitted over this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcTestStatusFailureReceived 1.3.6.1.2.1.10.227.1.11.1.31
This object counts the number of TestStatusFailure messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcTestStatusFailureSent 1.3.6.1.2.1.10.227.1.11.1.32
This object counts the number of TestStatusFailure messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcTestStatusFailureRetransmit 1.3.6.1.2.1.10.227.1.11.1.33
This object counts the number of TestStatusFailure messages that have been retransmitted over this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcTestStatusAckReceived 1.3.6.1.2.1.10.227.1.11.1.34
This object counts the number of TestStatusAck messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcTestStatusAckSent 1.3.6.1.2.1.10.227.1.11.1.35
This object counts the number of TestStatusAck messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcLinkSummaryReceived 1.3.6.1.2.1.10.227.1.11.1.36
This object counts the number of LinkSummary messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcLinkSummarySent 1.3.6.1.2.1.10.227.1.11.1.37
This object counts the number of LinkSummary messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcLinkSummaryRetransmit 1.3.6.1.2.1.10.227.1.11.1.38
This object counts the number of LinkSummary messages that have been retransmitted over this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcLinkSummaryAckReceived 1.3.6.1.2.1.10.227.1.11.1.39
This object counts the number of LinkSummaryAck messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcLinkSummaryAckSent 1.3.6.1.2.1.10.227.1.11.1.40
This object counts the number of LinkSummaryAck messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcLinkSummaryNackReceived 1.3.6.1.2.1.10.227.1.11.1.41
This object counts the number of LinkSummaryNack messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcLinkSummaryNackSent 1.3.6.1.2.1.10.227.1.11.1.42
This object counts the number of LinkSummaryNack messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusReceived 1.3.6.1.2.1.10.227.1.11.1.43
This object counts the number of ChannelStatus messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusSent 1.3.6.1.2.1.10.227.1.11.1.44
This object counts the number of ChannelStatus messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusRetransmit 1.3.6.1.2.1.10.227.1.11.1.45
This object counts the number of ChannelStatus messages that have been retransmitted on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusAckReceived 1.3.6.1.2.1.10.227.1.11.1.46
This object counts the number of ChannelStatusAck messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusAckSent 1.3.6.1.2.1.10.227.1.11.1.47
This object counts the number of ChannelStatus messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusReqReceived 1.3.6.1.2.1.10.227.1.11.1.48
This object counts the number of ChannelStatusRequest messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusReqSent 1.3.6.1.2.1.10.227.1.11.1.49
This object counts the number of ChannelStatusRequest messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusReqRetransmit 1.3.6.1.2.1.10.227.1.11.1.50
This object counts the number of ChannelStatusRequest messages that have been retransmitted on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusRspReceived 1.3.6.1.2.1.10.227.1.11.1.51
This object counts the number of ChannelStatusResponse messages that have been received on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcChannelStatusRspSent 1.3.6.1.2.1.10.227.1.11.1.52
This object counts the number of ChannelStatusResponse messages that have been sent on this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpCcCounterDiscontinuityTime 1.3.6.1.2.1.10.227.1.11.1.53
The value of sysUpTime on the most recent occasion at which one or more of this control channel's counters suffered a discontinuity. The relevant counters are the specific instances associated with this control channel of any Counter32 object contained in the lmpControlChannelPerfTable. If no such discontinuities have occurred since the last re- initialization of the local management subsystem, then this object contains a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

lmpTeLinkTable 1.3.6.1.2.1.10.227.1.12
This table specifies the LMP-specific TE link information. Overall TE link information is kept in three separate tables: ifTable for interface-specific information, lmpTeLinkTable for LMP specific information, and teLinkTable for generic TE link information. ifIndex is the common index to all tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LmpTeLinkEntry

lmpTeLinkEntry 1.3.6.1.2.1.10.227.1.12.1
An entry in this table exists for each ifEntry with an ifType of teLink(200) that is managed by LMP. An ifEntry with an ifIndex must exist before the corresponding lmpTeLinkEntry is created. If a TE link entry in the ifTable is destroyed, then so is the corresponding entry in the lmpTeLinkTable. The administrative status value is controlled from the ifEntry. Setting the administrative status to testing prompts LMP to start link verification on the TE link. Information about the TE link that is not LMP specific is contained in the teLinkTable of the TE-LINK-STD-MIB MIB module.
Status: current Access: not-accessible
OBJECT-TYPE    
  LmpTeLinkEntry  

lmpTeLinkNbrRemoteNodeId 1.3.6.1.2.1.10.227.1.12.1.1
This is the Node ID of the TE link remote node. This value may be learned during the control channel parameter negotiation phase (in the Config message). Node ID is an address whose type must be IPv4.
Status: current Access: read-create
OBJECT-TYPE    
  LmpNodeId  

lmpTeLinkVerification 1.3.6.1.2.1.10.227.1.12.1.2
This object indicates whether the LMP link verification procedure is enabled for this TE link.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

lmpTeLinkFaultManagement 1.3.6.1.2.1.10.227.1.12.1.3
This object indicates whether the LMP fault management procedure is enabled on this TE link.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

lmpTeLinkDwdm 1.3.6.1.2.1.10.227.1.12.1.4
This object indicates whether the LMP DWDM procedure is enabled on this TE link.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

lmpTeLinkOperStatus 1.3.6.1.2.1.10.227.1.12.1.5
The actual operational status of this TE link. The status is set to testing when the TE link is performing link verification. A degraded state indicates that there is no active control channel between the pair of nodes that form the endpoints of the TE link, but that at least one data-bearing link on the TE link is allocated.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3), init(4), degraded(5)  

lmpTeLinkRowStatus 1.3.6.1.2.1.10.227.1.12.1.6
This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). All read-create objects must have valid and consistent values before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

lmpTeLinkStorageType 1.3.6.1.2.1.10.227.1.12.1.7
The storage type for this conceptual row in the lmpTeLinkTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

lmpGlobalLinkVerificationInterval 1.3.6.1.2.1.10.227.1.13
This object indicates how often the link verification procedure is executed. The interval is in milliseconds. A value of 0 is used to indicate that the link verification procedure should not be executed. The interval specified in this object should be large enough to allow the verification procedure to be completed before the start of the next interval. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

lmpLinkVerificationTable 1.3.6.1.2.1.10.227.1.14
This table specifies TE link information associated with the LMP verification procedure.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LmpLinkVerificationEntry

lmpLinkVerificationEntry 1.3.6.1.2.1.10.227.1.14.1
An entry in this table is created by an LMP-enabled device for every TE link that supports the LMP verification procedure.
Status: current Access: not-accessible
OBJECT-TYPE    
  LmpLinkVerificationEntry  

lmpLinkVerifyInterval 1.3.6.1.2.1.10.227.1.14.1.1
This object specifies the VerifyInterval parameter used in the LMP link verification process. It indicates the interval at which the Test messages are sent.
Status: current Access: read-create
OBJECT-TYPE    
  LmpInterval  

lmpLinkVerifyDeadInterval 1.3.6.1.2.1.10.227.1.14.1.2
This object specifies the VerifyDeadInterval parameter used in the verification of the physical connectivity of data- bearing links. It specifies the observation period used to detect a Test message at the remote node.
Status: current Access: read-create
OBJECT-TYPE    
  LmpInterval  

lmpLinkVerifyTransportMechanism 1.3.6.1.2.1.10.227.1.14.1.3
This defines the transport mechanism for the Test messages. The scope of this bit mask is restricted to each link encoding type. The local node will set the bits corresponding to the various mechanisms it can support for transmitting LMP Test messages. The receiver chooses the appropriate mechanism in the BeginVerifyAck message.
Status: current Access: read-create
OBJECT-TYPE    
  BITS payload(0), dccSectionOverheadBytes(1), dccLineOverheadBytes(2), j0Trace(3), j1Trace(4), j2Trace(5)  


lmpLinkVerifyTransmissionRate 1.3.6.1.2.1.10.227.1.14.1.5
This is the transmission rate of the data link over which the Test messages will be transmitted and is expressed in bytes per second.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

lmpLinkVerifyWavelength 1.3.6.1.2.1.10.227.1.14.1.6
This value corresponds to the wavelength at which the Test messages will be transmitted and is measured in nanometers (nm). If each data-bearing link corresponds to a separate wavelength, then this value should be set to 0.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

lmpLinkVerifyRowStatus 1.3.6.1.2.1.10.227.1.14.1.7
This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). All read-create objects must have valid and consistent values before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

lmpLinkVerifyStorageType 1.3.6.1.2.1.10.227.1.14.1.8
The storage type for this conceptual row in the lmpLinkVerificationTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

lmpTeLinkPerfTable 1.3.6.1.2.1.10.227.1.15
This table specifies LMP TE link performance counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LmpTeLinkPerfEntry

lmpTeLinkPerfEntry 1.3.6.1.2.1.10.227.1.15.1
An entry in this table is created by an LMP-enabled device for every TE link. lmpTeCounterDiscontinuityTime is used to indicate potential discontinuity for all counter objects in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  LmpTeLinkPerfEntry  

lmpTeInOctets 1.3.6.1.2.1.10.227.1.15.1.1
The total number of LMP message octets received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeOutOctets 1.3.6.1.2.1.10.227.1.15.1.2
The total number of LMP message octets transmitted out for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeBeginVerifyReceived 1.3.6.1.2.1.10.227.1.15.1.3
This object counts the number of BeginVerify messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeBeginVerifySent 1.3.6.1.2.1.10.227.1.15.1.4
This object counts the number of BeginVerify messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeBeginVerifyRetransmit 1.3.6.1.2.1.10.227.1.15.1.5
This object counts the number of BeginVerify messages that have been retransmitted for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeBeginVerifyAckReceived 1.3.6.1.2.1.10.227.1.15.1.6
This object counts the number of BeginVerifyAck messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeBeginVerifyAckSent 1.3.6.1.2.1.10.227.1.15.1.7
This object counts the number of BeginVerifyAck messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeBeginVerifyNackReceived 1.3.6.1.2.1.10.227.1.15.1.8
This object counts the number of BeginVerifyNack messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeBeginVerifyNackSent 1.3.6.1.2.1.10.227.1.15.1.9
This object counts the number of BeginVerifyNack messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeEndVerifyReceived 1.3.6.1.2.1.10.227.1.15.1.10
This object counts the number of EndVerify messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeEndVerifySent 1.3.6.1.2.1.10.227.1.15.1.11
This object counts the number of EndVerify messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeEndVerifyRetransmit 1.3.6.1.2.1.10.227.1.15.1.12
This object counts the number of EndVerify messages that have been retransmitted over this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeEndVerifyAckReceived 1.3.6.1.2.1.10.227.1.15.1.13
This object counts the number of EndVerifyAck messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeEndVerifyAckSent 1.3.6.1.2.1.10.227.1.15.1.14
This object counts the number of EndVerifyAck messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeTestStatusSuccessReceived 1.3.6.1.2.1.10.227.1.15.1.15
This object counts the number of TestStatusSuccess messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeTestStatusSuccessSent 1.3.6.1.2.1.10.227.1.15.1.16
This object counts the number of TestStatusSuccess messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeTestStatusSuccessRetransmit 1.3.6.1.2.1.10.227.1.15.1.17
This object counts the number of TestStatusSuccess messages that have been retransmitted for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeTestStatusFailureReceived 1.3.6.1.2.1.10.227.1.15.1.18
This object counts the number of TestStatusFailure messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeTestStatusFailureSent 1.3.6.1.2.1.10.227.1.15.1.19
This object counts the number of TestStatusFailure messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeTestStatusFailureRetransmit 1.3.6.1.2.1.10.227.1.15.1.20
This object counts the number of TestStatusFailure messages that have been retransmitted on this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeTestStatusAckReceived 1.3.6.1.2.1.10.227.1.15.1.21
This object counts the number of TestStatusAck messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeTestStatusAckSent 1.3.6.1.2.1.10.227.1.15.1.22
This object counts the number of TestStatusAck messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeLinkSummaryReceived 1.3.6.1.2.1.10.227.1.15.1.23
This object counts the number of LinkSummary messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeLinkSummarySent 1.3.6.1.2.1.10.227.1.15.1.24
This object counts the number of LinkSummary messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeLinkSummaryRetransmit 1.3.6.1.2.1.10.227.1.15.1.25
This object counts the number of LinkSummary messages that have been retransmitted over this control channel.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeLinkSummaryAckReceived 1.3.6.1.2.1.10.227.1.15.1.26
This object counts the number of LinkSummaryAck messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeLinkSummaryAckSent 1.3.6.1.2.1.10.227.1.15.1.27
This object counts the number of LinkSummaryAck messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeLinkSummaryNackReceived 1.3.6.1.2.1.10.227.1.15.1.28
This object counts the number of LinkSummaryNack messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeLinkSummaryNackSent 1.3.6.1.2.1.10.227.1.15.1.29
This object counts the number of LinkSummaryNack messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusReceived 1.3.6.1.2.1.10.227.1.15.1.30
This object counts the number of ChannelStatus messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusSent 1.3.6.1.2.1.10.227.1.15.1.31
This object counts the number of ChannelStatus messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusRetransmit 1.3.6.1.2.1.10.227.1.15.1.32
This object counts the number of ChannelStatus messages that have been retransmitted for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusAckReceived 1.3.6.1.2.1.10.227.1.15.1.33
This object counts the number of ChannelStatusAck messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusAckSent 1.3.6.1.2.1.10.227.1.15.1.34
This object counts the number of ChannelStatus messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusReqReceived 1.3.6.1.2.1.10.227.1.15.1.35
This object counts the number of ChannelStatusRequest messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusReqSent 1.3.6.1.2.1.10.227.1.15.1.36
This object counts the number of ChannelStatusRequest messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusReqRetransmit 1.3.6.1.2.1.10.227.1.15.1.37
This object counts the number of ChannelStatusRequest messages that have been retransmitted for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusRspReceived 1.3.6.1.2.1.10.227.1.15.1.38
This object counts the number of ChannelStatusResponse messages that have been received for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeChannelStatusRspSent 1.3.6.1.2.1.10.227.1.15.1.39
This object counts the number of ChannelStatusResponse messages that have been sent for this TE link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpTeCounterDiscontinuityTime 1.3.6.1.2.1.10.227.1.15.1.40
The value of sysUpTime on the most recent occasion at which one or more of this TE link's counters suffered a discontinuity. The relevant counters are the specific instances associated with this TE link of any Counter32 object contained in the lmpTeLinkPerfTable. If no such discontinuities have occurred since the last re- initialization of the local management subsystem, then this object contains a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

lmpDataLinkTable 1.3.6.1.2.1.10.227.1.16
This table specifies the data-bearing links managed by the LMP.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LmpDataLinkEntry

lmpDataLinkEntry 1.3.6.1.2.1.10.227.1.16.1
An entry in this table exists for each ifEntry that represents a data-bearing link. An ifEntry with an ifIndex must exist before the corresponding lmpDataLinkEntry is created. If an entry representing the data-bearing link is destroyed in the ifTable, then so is the corresponding entry in the lmpDataLinkTable. The administrative status value is controlled from the ifEntry. The index to this table is also used to get information in the componentLinkTable of the TE-LINK-STD-MIB MIB module.
Status: current Access: not-accessible
OBJECT-TYPE    
  LmpDataLinkEntry  

lmpDataLinkType 1.3.6.1.2.1.10.227.1.16.1.1
This attribute specifies whether this data-bearing link is a port or a component link. Component links are multiplex capable, whereas ports are not multiplex capable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER port(1), componentLink(2)  

lmpDataLinkAddressType 1.3.6.1.2.1.10.227.1.16.1.2
This attribute specifies the data-bearing link IP address type. If the data-bearing link is unnumbered, the address type must be set to unknown(0).
Status: current Access: read-create
OBJECT-TYPE    
  InetAddressType  

lmpDataLinkIpAddr 1.3.6.1.2.1.10.227.1.16.1.3
The local Internet address for numbered links. The type of this address is determined by the value of lmpDataLinkAddressType object. For IPv4 and IPv6 numbered links, this object represents the local IP address associated with the data-bearing link. For an unnumbered link, the local address is of type unknown, and this object is set to the zero-length string; the ifIndex object then identifies the unnumbered address.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddress  

lmpDataLinkRemoteIpAddress 1.3.6.1.2.1.10.227.1.16.1.4
The remote Internet address for numbered data-bearing links. The type of this address is determined by the lmpDataLinkAddressType object. For IPv4 and IPv6 numbered links, this object represents the remote IP address associated with the data-bearing link. For an unnumbered link, the remote address is of type unknown, and this object is set to the zero-length string; the lmpDataLinkRemoteIfId object then identifies the unnumbered address. This information is either configured manually or communicated by the remote node during the link verification procedure.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddress  

lmpDataLinkRemoteIfId 1.3.6.1.2.1.10.227.1.16.1.5
Interface identifier of the remote end point. This information is either configured manually or communicated by the remote node during the link verification procedure.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

lmpDataLinkEncodingType 1.3.6.1.2.1.10.227.1.16.1.6
The encoding type of the data-bearing link.
Status: current Access: read-create
OBJECT-TYPE    
  TeLinkEncodingType  

lmpDataLinkActiveOperStatus 1.3.6.1.2.1.10.227.1.16.1.7
The actual operational status of this data-bearing link (active FSM).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER upAlloc(1), upFree(2), down(3), testing(4)  

lmpDataLinkPassiveOperStatus 1.3.6.1.2.1.10.227.1.16.1.8
The actual operational status of this data-bearing link (passive FSM).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER upAlloc(1), upFree(2), down(3), psvTst(4)  

lmpDataLinkRowStatus 1.3.6.1.2.1.10.227.1.16.1.9
This variable is used to create, modify, and/or delete a row in this table. None of the writable objects in a row can be changed if the status is active(1). All read-create objects must have valid and consistent values before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

lmpDataLinkStorageType 1.3.6.1.2.1.10.227.1.16.1.10
The storage type for this conceptual row in the lmpDataLinkTable. Conceptual rows having the value 'permanent' need not allow write-access to any columnar object in the row.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

lmpDataLinkPerfTable 1.3.6.1.2.1.10.227.1.17
This table specifies the data-bearing links LMP performance counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LmpDataLinkPerfEntry

lmpDataLinkPerfEntry 1.3.6.1.2.1.10.227.1.17.1
An entry in this table contains information about the LMP performance counters for the data-bearing links. lmpDataLinkDiscontinuityTime is used to indicate potential discontinuity for all counter objects in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  LmpDataLinkPerfEntry  

lmpDataLinkTestReceived 1.3.6.1.2.1.10.227.1.17.1.1
This object counts the number of Test messages that have been received on this data-bearing link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpDataLinkTestSent 1.3.6.1.2.1.10.227.1.17.1.2
This object counts the number of Test messages that have been sent on this data-bearing link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpDataLinkActiveTestSuccess 1.3.6.1.2.1.10.227.1.17.1.3
This object counts the number of data-bearing link tests that were successful on the active side of this data- bearing link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpDataLinkActiveTestFailure 1.3.6.1.2.1.10.227.1.17.1.4
This object counts the number of data-bearing link tests that failed on the active side of this data-bearing link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpDataLinkPassiveTestSuccess 1.3.6.1.2.1.10.227.1.17.1.5
This object counts the number of data-bearing link tests that were successful on the passive side of this data- bearing link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpDataLinkPassiveTestFailure 1.3.6.1.2.1.10.227.1.17.1.6
This object counts the number of data-bearing link tests that failed on the passive side of this data-bearing link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

lmpDataLinkDiscontinuityTime 1.3.6.1.2.1.10.227.1.17.1.7
The value of sysUpTime on the most recent occasion at which one or more of this data-bearing link's counters suffered a discontinuity. The relevant counters are the specific instances associated with this data-bearing link of any Counter32 object contained in the lmpDataLinkPerfTable. If no such discontinuities have occurred since the last re- initialization of the local management subsystem, then this object contains a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

lmpNotificationMaxRate 1.3.6.1.2.1.10.227.1.18
The LMP notification rate depends on the size of the network, the type of links, the network configuration, the reliability of the network, etc. When this MIB was designed, care was taken to minimize the amount of notifications generated for LMP purposes. Wherever possible, notifications are state driven, meaning that the notifications are sent only when the system changes state. The only notifications that are repeated and that could cause a problem as far as congestion is concerned are the ones associated with data link verification. Without any considerations to handling of these notifications, a problem may arise if the number of data links is high. Since the data link verification notifications can happen only once per data link per link verification interval, the notification rate should be sustainable if one chooses an appropriate link verification interval for a given network configuration. For instance, a network of 100 nodes with 5 links of 128 wavelengths each and a link verification of 1 minute, where no more than 10% of the links failed at any given time, would have 1 notification per second sent from each node, or 100 notifications per second for the whole network. The rest of the notifications are negligible compared to this number. To alleviate the congestion problem, the lmpNotificationMaxRate object can be used to implement a throttling mechanism. It is also possible to enable/disable certain type of notifications. This variable indicates the maximum number of notifications issued per minute. If events occur more rapidly, the implementation may simply fail to emit these notifications during that period or may queue them until an appropriate time. A value of 0 means that no throttling is applied and events may be notified at the rate at which they occur. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

lmpLinkPropertyNotificationsEnabled 1.3.6.1.2.1.10.227.1.19
If this object is true(1), then it enables the generation of lmpTeLinkPropertyMismatch and lmpDataLinkPropertyMismatch notifications; otherwise, these notifications are not emitted. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

lmpUnprotectedNotificationsEnabled 1.3.6.1.2.1.10.227.1.20
If this object is true(1), then it enables the generation of lmpUnprotected notifications; otherwise, these notifications are not emitted. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

lmpCcUpDownNotificationsEnabled 1.3.6.1.2.1.10.227.1.21
If this object is true(1), then it enables the generation of lmpControlChannelUp and lmpControlChannelDown notifications; otherwise, these notifications are not emitted. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

lmpTeLinkNotificationsEnabled 1.3.6.1.2.1.10.227.1.22
If this object is true(1), then it enables the generation of lmpTeLinkDegraded and lmpTeLinkNotDegraded notifications; otherwise, these notifications are not emitted. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

lmpDataLinkNotificationsEnabled 1.3.6.1.2.1.10.227.1.23
If this object is true(1), then it enables the generation of lmpDataLinkVerificationFailure notification; otherwise, these notifications are not emitted. Implementations should save the value of this object in persistent memory so that it survives restarts or reboot.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

lmpTeLinkPropertyMismatch 1.3.6.1.2.1.10.227.0.1
This notification is generated when a TE link property mismatch is detected on the node. The received remote TE link ID of the misconfigured TE link is represented by either teLinkRemoteIpAddr or teLinkIncomingIfId, depending on whether the TE link is numbered or unnumbered. This notification should not be sent unless lmpLinkPropertyNotificationsEnabled is true(1). It is recommended that this notification be reported only the first time a mismatch is detected. Otherwise, for a given TE link, this notification can occur no more than once per verification interval (lmpGlobalLinkVerificationInterval).
Status: current Access: read-write
NOTIFICATION-TYPE    

lmpDataLinkPropertyMismatch 1.3.6.1.2.1.10.227.0.2
This notification is generated when a data-bearing link property mismatch is detected on the node. lmpDataLinkType is used to identify the local identifiers associated with the data link. (The data link interface index can be used to determine the TE link interface index, as this relationship is captured in the interface stack table.) The remote entity interface ID is the remote entity interface ID received in the LinkSummary message. This notification should not be sent unless lmpLinkPropertyNotificationsEnabled is true(1). It is recommended that this notification be reported only the first time a mismatch is detected. Otherwise, for a given data link, this notification can occur no more than once per verification interval (lmpGlobalLinkVerificationInterval).
Status: current Access: read-write
NOTIFICATION-TYPE    

lmpUnprotected 1.3.6.1.2.1.10.227.0.3
This notification is generated when there is more than one control channel between LMP neighbors and the last redundant control channel has failed. If the remaining operational control channel fails, then there will be no more control channels between the pair of nodes and all the TE links between the pair of nodes, will go to degraded state. This notification should not be sent unless lmpUnprotectedNotificationsEnabled is set to true(1).
Status: current Access: read-write
NOTIFICATION-TYPE    

lmpControlChannelUp 1.3.6.1.2.1.10.227.0.4
This notification is generated when a control channel transitions to the up operational state. This notification should not be sent unless lmpCcUpDownNotificationsEnabled is true(1).
Status: current Access: read-write
NOTIFICATION-TYPE    

lmpControlChannelDown 1.3.6.1.2.1.10.227.0.5
This notification is generated when a control channel transitions out of the up operational state. This notification should not be sent unless lmpCcUpDownNotificationsEnabled is true(1).
Status: current Access: read-write
NOTIFICATION-TYPE    

lmpTeLinkDegraded 1.3.6.1.2.1.10.227.0.6
This notification is generated when a lmpTeLinkOperStatus object for a TE link enters the degraded state. This notification should not be sent unless lmpTeLinkNotificationsEnabled is true(1).
Status: current Access: read-write
NOTIFICATION-TYPE    

lmpTeLinkNotDegraded 1.3.6.1.2.1.10.227.0.7
This notification is generated when a lmpTeLinkOperStatus object for a TE link leaves the degraded state. This notification should not be sent unless lmpTeLinkNotificationsEnabled is true(1).
Status: current Access: read-write
NOTIFICATION-TYPE    

lmpDataLinkVerificationFailure 1.3.6.1.2.1.10.227.0.8
This notification is generated when a data-bearing link verification fails. This notification should not be sent unless lmpDataLinkNotificationsEnabled is true(1). For a given data link, this notification can occur no more than once per verification interval (lmpGlobalLinkVerificationInterval).
Status: current Access: read-write
NOTIFICATION-TYPE    

lmpCompliances 1.3.6.1.2.1.10.227.2.1
OBJECT IDENTIFIER    

lmpGroups 1.3.6.1.2.1.10.227.2.2
OBJECT IDENTIFIER    

lmpModuleFullCompliance 1.3.6.1.2.1.10.227.2.1.1
Compliance statement for agents that support the configuration and monitoring of LMP MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

lmpModuleReadOnlyCompliance 1.3.6.1.2.1.10.227.2.1.2
Compliance statement for agents that support the monitoring of the LMP MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

lmpNodeGroup 1.3.6.1.2.1.10.227.2.2.1
Collection of objects that represent LMP node configuration.
Status: current Access: read-only
OBJECT-GROUP    

lmpControlChannelGroup 1.3.6.1.2.1.10.227.2.2.2
Objects that can be used to configure LMP interface.
Status: current Access: read-only
OBJECT-GROUP    

lmpCcIsInterfaceGroup 1.3.6.1.2.1.10.227.2.2.3
Objects that can be used to configure control channels that are interfaces.
Status: current Access: read-only
OBJECT-GROUP    

lmpCcIsNotInterfaceGroup 1.3.6.1.2.1.10.227.2.2.4
Objects that can be used to configure control channels that are not interfaces.
Status: current Access: read-only
OBJECT-GROUP    

lmpLinkPropertyCorrelationGroup 1.3.6.1.2.1.10.227.2.2.5
Collection of objects used to configure the link property correlation procedure.
Status: current Access: read-only
OBJECT-GROUP    

lmpLinkVerificationGroup 1.3.6.1.2.1.10.227.2.2.6
Collection of objects that represent the link verification procedure configuration.
Status: current Access: read-only
OBJECT-GROUP    

lmpPerfGroup 1.3.6.1.2.1.10.227.2.2.7
Collection of objects used to provide performance information about LMP interfaces and data-bearing links.
Status: current Access: read-only
OBJECT-GROUP    

lmpTeLinkGroup 1.3.6.1.2.1.10.227.2.2.8
Objects that can be used to configure TE links.
Status: current Access: read-only
OBJECT-GROUP    

lmpDataLinkGroup 1.3.6.1.2.1.10.227.2.2.9
Collection of objects that represent data-bearing link configuration.
Status: current Access: read-only
OBJECT-GROUP    

lmpNotificationGroup 1.3.6.1.2.1.10.227.2.2.10
Set of notifications defined in this module.
Status: current Access: read-only
NOTIFICATION-GROUP