LIEBERT-UPS-MIB
File:
LIEBERT-UPS-MIB.mib (71621 bytes)
Imported modules
Imported symbols
Defined Types
LcUpsInputEntry |
|
SEQUENCE |
|
|
|
|
lcUpsInputLine |
INTEGER |
|
|
lcUpsInputVoltage |
INTEGER |
|
|
lcUpsInputCurrent |
INTEGER |
|
|
lcUpsInputVA |
INTEGER |
|
LcUpsOutputEntry |
|
SEQUENCE |
|
|
|
|
lcUpsOutputLine |
INTEGER |
|
|
lcUpsOutputVoltage |
INTEGER |
|
|
lcUpsOutputCurrent |
INTEGER |
|
|
lcUpsOutputVA |
INTEGER |
|
LcUpsAlarmEntry |
|
SEQUENCE |
|
|
|
|
lcUpsAlarmId |
INTEGER |
|
|
lcUpsAlarmDescr |
OBJECT IDENTIFIER |
|
|
lcUpsAlarmTime |
TimeTicks |
|
LcUpsBypassEntry |
|
SEQUENCE |
|
|
|
|
lcUpsBypassLine |
INTEGER |
|
|
lcUpsBypassVoltage |
INTEGER |
|
|
lcUpsBypassCurrent |
INTEGER |
|
LcUpsSwitchedReceptEntry |
|
SEQUENCE |
|
|
|
|
lcUpsSwitchedReceptIndex |
INTEGER |
|
|
lcUpsSwitchedReceptOnDelay |
INTEGER |
|
|
lcUpsSwitchedReceptOnTrapDelay |
INTEGER |
|
|
lcUpsSwitchedReceptOffDelay |
INTEGER |
|
|
lcUpsSwitchedReceptOffTrapDelay |
INTEGER |
|
|
lcUpsSwitchedReceptStatus |
INTEGER |
|
|
lcUpsSwitchedReceptLabel |
DisplayString |
|
LsUpsBypassEntry |
|
SEQUENCE |
|
|
|
|
lsUpsBypassLine |
INTEGER |
|
|
lsUpsBypassVoltage |
INTEGER |
|
|
lsUpsBypassCurrent |
INTEGER |
|
Ls43cUpsBypassEntry |
|
SEQUENCE |
|
|
|
|
ls43cUpsBypassLine |
INTEGER |
|
|
ls43cUpsBypassVoltage |
INTEGER |
|
|
ls43cUpsBypassCurrent |
INTEGER |
|
Defined Values
emerson |
1.3.6.1.4.1.476 |
OBJECT IDENTIFIER |
|
|
|
luPrivate |
1.3.6.1.4.1.476.1.1.3 |
OBJECT IDENTIFIER |
|
|
|
luCore |
1.3.6.1.4.1.476.1.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
lcUpsIdent |
1.3.6.1.4.1.476.1.1.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
lcUpsIdentModel |
1.3.6.1.4.1.476.1.1.1.1.1.2 |
The UPS Model designation. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(255) |
|
lcUpsIdentSpecific |
1.3.6.1.4.1.476.1.1.1.1.1.4 |
A reference to MIB definitions specific to the
particular UPS being managed. This object is
used to locate the product-specific MIB for this
device.
If this information is not present, its value
should be the OBJECT IDENTIFIER { 0 0 },
which is a syntactically valid object identifier,
and any conformant implementation of ASN.1 and BER
must be able to generate and recognize this
value. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
lcUpsBatTimeRemaining |
1.3.6.1.4.1.476.1.1.1.1.2.1 |
The estimated time to depletion of battery charge.
(Unit of measure: Minute) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
lcUpsBatTemperature |
1.3.6.1.4.1.476.1.1.1.1.2.2 |
The battery temperature. (Unit of measure:
Degree, Centigrade) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-32768..32767 |
|
lcUpsBatVoltage |
1.3.6.1.4.1.476.1.1.1.1.2.3 |
The current battery voltage. (Unit of measure:
volt) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-32768..32767 |
|
lcUpsBatCurrent |
1.3.6.1.4.1.476.1.1.1.1.2.4 |
The current battery discharging/charging current.
(Unit of measure: Amp) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-32768..32767 |
|
lcUpsBatCapacity |
1.3.6.1.4.1.476.1.1.1.1.2.6 |
The current battery capacity in percentage of
total available. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..100 |
|
lcUpsBatTotalDischCounts |
1.3.6.1.4.1.476.1.1.1.1.2.7 |
The number of discharges the UPS has
experienced. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
lcUpsBatAmpHours |
1.3.6.1.4.1.476.1.1.1.1.2.9 |
The number of amp hours withdrawn from battery. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
lcUpsBatKWhours |
1.3.6.1.4.1.476.1.1.1.1.2.10 |
The number of Kilowatt-hours withdrawn from battery. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
lcUpsBatWattHours |
1.3.6.1.4.1.476.1.1.1.1.2.11 |
The number of Watt-hours withdrawn from battery. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
lcUpsOutput |
1.3.6.1.4.1.476.1.1.1.1.4 |
OBJECT IDENTIFIER |
|
|
|
lcUpsOutputFrequency |
1.3.6.1.4.1.476.1.1.1.1.4.1 |
The current output frequency. (Unit of measure:
Hertz) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsOutputLoad |
1.3.6.1.4.1.476.1.1.1.1.4.2 |
The current output load percentage. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..100 |
|
lcUpsOutputNumLines |
1.3.6.1.4.1.476.1.1.1.1.4.3 |
The number of output lines utilized in this
device. This entry indicates the number of rows in
the output table. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..3 |
|
lcUpsOutputEntry |
1.3.6.1.4.1.476.1.1.1.1.4.4.1 |
Tok_String |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LcUpsOutputEntry |
|
|
lcUpsOutputLine |
1.3.6.1.4.1.476.1.1.1.1.4.4.1.1 |
The output Line. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..3 |
|
lcUpsOutputVoltage |
1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 |
The output voltage. (Unit of measure: Volt) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsOutputCurrent |
1.3.6.1.4.1.476.1.1.1.1.4.4.1.3 |
The output current. (Unit of measure: Amp) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsOutputVA |
1.3.6.1.4.1.476.1.1.1.1.4.4.1.4 |
The output volt-amps. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsOutputWatts |
1.3.6.1.4.1.476.1.1.1.1.4.5 |
The output power in watts. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsInverterStatus |
1.3.6.1.4.1.476.1.1.1.1.5.1 |
The state of the inverter. Unknown is returned if
the state can not be determined. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), on(2), off(3) |
|
lcUpsInverterTemp |
1.3.6.1.4.1.476.1.1.1.1.5.2 |
The temperature of the inverter. (Unit of
measure: degree, Centigrade) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-32768..32767 |
|
lcUpsAlarm |
1.3.6.1.4.1.476.1.1.1.1.6 |
OBJECT IDENTIFIER |
|
|
|
lcUpsAlarms |
1.3.6.1.4.1.476.1.1.1.1.6.1 |
The current number of alarm conditions. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge |
|
|
lcUpsAlarmEntry |
1.3.6.1.4.1.476.1.1.1.1.6.2.1 |
Tok_String |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LcUpsAlarmEntry |
|
|
lcUpsAlarmId |
1.3.6.1.4.1.476.1.1.1.1.6.2.1.1 |
A unique identifier for an alarm condition. This
value must remain constant between agent
initializations. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsAlarmDescr |
1.3.6.1.4.1.476.1.1.1.1.6.2.1.2 |
A reference to an alarm description object. The
object referenced should not be accessible, but
rather be used to provide a unique description of
the alarm condition. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
lcUpsAlarmTime |
1.3.6.1.4.1.476.1.1.1.1.6.2.1.3 |
The value of sysUpTime when the alarm condition
occured. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
lcUpsTest |
1.3.6.1.4.1.476.1.1.1.1.7 |
OBJECT IDENTIFIER |
|
|
|
lcUpsTestBattery |
1.3.6.1.4.1.476.1.1.1.1.7.1 |
Setting this variable to 'start' will initiate
the battery test. Setting this variable to 'abort'
will stop the battery test if the test is in-
progress, otherwise it has no effect. Setting this
variable to 'unknown' has no effect. Reading this
variable will always result in a return value of
'unknown'. If 'lcUpsTestBatteryStatus' is 'failed'
the test may not be performed again and the status
will remain in the failure state. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), start(2), abort(3) |
|
lcUpsTestBatteryStatus |
1.3.6.1.4.1.476.1.1.1.1.7.2 |
The status of the battery test. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), passed(2), failed(3), inProgress(4), sysFailure(5), notSupported(6), inhibited(7) |
|
lcUpsTestDiag |
1.3.6.1.4.1.476.1.1.1.1.7.3 |
Setting this variable to 'start' will initiate
the diagnostics test. Setting this variable to
'abort' will stop the diagnostics test if the test
is in-progress, otherwise it has no effect. Setting
this variable to 'unknown' has no effect. Reading this
variable will always result in a return value of
'unknown'. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), start(2), abort(3) |
|
lcUpsTestDiagStatus |
1.3.6.1.4.1.476.1.1.1.1.7.4 |
The status of the diagnostics test. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), passed(2), failed(3), inProgress(4), sysFailure(5), notSupported(6), inhibited(7) |
|
lcUpsControlOutputOffDelay |
1.3.6.1.4.1.476.1.1.1.1.8.1 |
Setting this object causes the agent to instruct
the UPS to turn off the output after the indicated
number of seconds. The agent counts down the number
of seconds until the event will take place. The
agent issues an lcUpsOutputOffTrap when the countdown
finishes. Note that different models have different
clock resolutions, usually greater than 1 second. As
a result, the command will only be accurate to the
resolution of the UPS's clock.
The command can be cancelled by setting
lcUpsControlCancelCommand to the value cancel. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsControlOutputOnDelay |
1.3.6.1.4.1.476.1.1.1.1.8.2 |
Setting this object causes the agent to instruct
the UPS to turn on the output after the indicated
number of seconds. The agent counts down the number
of seconds until the event will take place. The
agent issues an lcUpsOutputOnTrap when the countdown
finishes. Note that different models have different
clock resolutions, usually greater than 1 second. As
a result, the command will only be accurate to the
resolution of the UPS's clock.
The command can be cancelled by setting
lcUpsControlCancelCommand to the value cancel. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsControlOutputOffTrapDelay |
1.3.6.1.4.1.476.1.1.1.1.8.3 |
When 'lcUpsControlOutputOffDelay' reaches a value
less than or equal to this object's value, an
lcUpsOutputOffWarningTrap will be produced and this
object will be reset to 0. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsControlOutputOnTrapDelay |
1.3.6.1.4.1.476.1.1.1.1.8.4 |
When 'lcUpsControlOutputOnDelay' reaches a value
less than or equal to this object's value, an
lcUpsOutputOnWarningTrap will be produced and this
object will be reset to 0. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsControlUnixShutdownDelay |
1.3.6.1.4.1.476.1.1.1.1.8.5 |
Setting this object causes the agent to instruct
the UPS to perform a UNIX Shutdown in the indicated
number of seconds. The agent counts down the number
of seconds until the event will take place. A Unix
shutdown is only valid if the UPS is on Battery.
During a UNIX Shutdown, the UPS will turn off the
output even if the Utility comes back on line before
the shutdown time arrives. Note that different models
have different clock resolutions, usually greater
than 1 second. As a result, the command will only
be accurate to the resolution of the UPS's clock.
The command can be cancelled by setting
lcUpsControlCancelCommand to the value 'cancel'. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsControlUnixShutdownTrapDelay |
1.3.6.1.4.1.476.1.1.1.1.8.6 |
When 'lcUpsControlUnixShutdownDelay' reaches a value
less than or equal to this object's value, an
lcUpsUnixShutdownWarningTrap will be produced and
this object will be reset to 0. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsControlCancelCommands |
1.3.6.1.4.1.476.1.1.1.1.8.7 |
Setting this variable to 'cancel' will cause the
agent to issue instructions to the UPS to cancel all
outstanding commands, such as lcUpsControlOutputOff,
lcUpsControlOutputOn, lcUpsControlUnixShutdown. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), cancel(2) |
|
lcUpsControlRebootAgentDelay |
1.3.6.1.4.1.476.1.1.1.1.8.8 |
Setting this object causes the agent to reboot after
the indicated number of seconds have expired. The
value will count down until the event takes place. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsNominalOutputVoltage |
1.3.6.1.4.1.476.1.1.1.1.9.1 |
The nominal output voltage. (Unit of measure:
volt) |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsNominalOutputVA |
1.3.6.1.4.1.476.1.1.1.1.9.3 |
The nominal Volt-Amp rating. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsNominalOutputWatts |
1.3.6.1.4.1.476.1.1.1.1.9.4 |
The nominal power rating. (Unit of measure:
watt) |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsNominalOutputFreq |
1.3.6.1.4.1.476.1.1.1.1.9.5 |
The nominal output frequency. (Unit of measure:
Hertz) |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsNominalOutputVaRating |
1.3.6.1.4.1.476.1.1.1.1.9.7 |
The nominal Volt-Amp rating. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsNominalOutputWattsRating |
1.3.6.1.4.1.476.1.1.1.1.9.8 |
The nominal power rating. (Unit of measure:
watt) |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsBypass |
1.3.6.1.4.1.476.1.1.1.1.13 |
OBJECT IDENTIFIER |
|
|
|
lcUpsOnBypass |
1.3.6.1.4.1.476.1.1.1.1.13.1 |
Indicates that the UPS is currently on bypass. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), yes(2), no(3), maintenance(4) |
|
lcUpsBypassFrequency |
1.3.6.1.4.1.476.1.1.1.1.13.2 |
The current bypass frequency. (Unit of measure:
Hertz) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsBypassNumLines |
1.3.6.1.4.1.476.1.1.1.1.13.3 |
The number of bypass lines utilized in this
device. This entry indicates the number of rows in
the bypass table. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..3 |
|
lcUpsBypassEntry |
1.3.6.1.4.1.476.1.1.1.1.13.4.1 |
Tok_String |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LcUpsBypassEntry |
|
|
lcUpsBypassLine |
1.3.6.1.4.1.476.1.1.1.1.13.4.1.1 |
The bypass Line. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..3 |
|
lcUpsBypassVoltage |
1.3.6.1.4.1.476.1.1.1.1.13.4.1.2 |
The bypass voltage. (Unit of measure: Volt) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsBypassCurrent |
1.3.6.1.4.1.476.1.1.1.1.13.4.1.3 |
The bypass current. (Unit of measure: Amp) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsConfig |
1.3.6.1.4.1.476.1.1.1.1.14 |
OBJECT IDENTIFIER |
|
|
|
lcUpsConfigType |
1.3.6.1.4.1.476.1.1.1.1.14.1 |
Indicates the UPS topology. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), online(2), offline(3), lineinteractive(4) |
|
lcUpsConfigBypassInstalled |
1.3.6.1.4.1.476.1.1.1.1.14.2 |
Indicates if a bypass is installed in the UPS. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), yes(2), no(3), dualinput(4) |
|
lcUpsConfigModuleCount |
1.3.6.1.4.1.476.1.1.1.1.14.3 |
A number identifying how many multi-module UPS are
connected to the System Control Cabinet. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..16 |
|
lcUpsConfigCurrentModule |
1.3.6.1.4.1.476.1.1.1.1.14.4 |
A number identifying which module of a multi-module UPS
is currently being monitored. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..16 |
|
lcUpsConfigAudibleStatus |
1.3.6.1.4.1.476.1.1.1.1.14.5 |
The requested state of the audible alarm. When in
the disabled state, the audible alarm should never
sound. The enabled state is self-describing. Setting
this object to muted(3) when the audible alarm is
sounding shall temporarily silence the alarm. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabled(2), muted(3) |
|
lcUpsConfigLowBattTime |
1.3.6.1.4.1.476.1.1.1.1.14.6 |
The value of lcUpsBatTimeRemaining at which a
lowBatteryWarning condition is declared.
(Unit of measure: Minute) |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
lcUpsConfigAutoRestart |
1.3.6.1.4.1.476.1.1.1.1.14.7 |
Setting this object will start the output after the
indicated number of ticks (1 tick = 10 seconds),
including starting the UPS, if necessary. Setting this
object to 0 will cause the startup to occur immediately.
Setting this object to -1 will disable autorestart. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-1..32767 |
|
lcUpsSwitchedReceptMaxNum |
1.3.6.1.4.1.476.1.1.1.1.12.1 |
The maximum number of switched receptacles supported by the Ups. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
lcUpsSwitchedReceptEntry |
1.3.6.1.4.1.476.1.1.1.1.12.2.1 |
Tok_String |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LcUpsSwitchedReceptEntry |
|
|
lcUpsSwitchedReceptIndex |
1.3.6.1.4.1.476.1.1.1.1.12.2.1.1 |
Tok_String |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
lcUpsSwitchedReceptOnDelay |
1.3.6.1.4.1.476.1.1.1.1.12.2.1.2 |
Setting this object causes the agent to instruct
the UPS to turn on a receptacle after the indicated number
of seconds. The agent counts down the number of seconds
until the event will take place. The agent issues an
lcUpsReceptOnTrap when the countdown finishes.
Note that different models have different clock
resolutions, usually greater than 1 second. As a result,
the command will only be accurate to the resolution of the
UPS's clock.
The command can be cancelled by setting
lcUpsSwitchedCancelCommand to the value cancel. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsSwitchedReceptOnTrapDelay |
1.3.6.1.4.1.476.1.1.1.1.12.2.1.3 |
When 'lcUpsSwitchedReceptOnDelay' reaches a value less
than or equal to this object's value, an
lcUpsReceptOnWarningTrap will be produced and this object
will be reset to 0. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsSwitchedReceptOffDelay |
1.3.6.1.4.1.476.1.1.1.1.12.2.1.4 |
Setting this object causes the agent to instruct the UPS
to turn off a receptacle after the indicated number of
seconds. The agent counts down the number of seconds
until the event will take place. The agent issues an
lcUpsReceptOffTrap when the countdown finishes. Note that
different models have different clock resolutions, usually
greater than 1 second. As a result, the command will only
be accurate to the resolution of the UPS's clock.
The command can be cancelled by setting
lcUpsSwitchedCancelCommand to the value cancel. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsSwitchedReceptOffTrapDelay |
1.3.6.1.4.1.476.1.1.1.1.12.2.1.5 |
When 'lcUpsSwitchedReceptOffDelay' reaches a value less
than or equal to this object's value, an
lcUpsReceptOffWarningTrap will be produced and this object
will be reset to 0. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsSwitchedReceptStatus |
1.3.6.1.4.1.476.1.1.1.1.12.2.1.6 |
The status of the device receptacle. Note that some
devices may support Switched of device receptacles as a
group only (by using lcUpsSwitchedOutputOffDelay
and lcUpsSwitchedOutputOnDelay). |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
on(1), off(2) |
|
lcUpsSwitchedReceptLabel |
1.3.6.1.4.1.476.1.1.1.1.12.2.1.7 |
A user-defined text string associated with a switched
receptacle. This may be used to describe the load
powered from the receptacle. The text string is
stored in non-volatile memory. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(32) |
|
lcUpsTraps |
1.3.6.1.4.1.476.1.1.1.1.11 |
OBJECT IDENTIFIER |
|
|
|
lcUpsOverloadWarningTrap |
1 |
An lcUpsOverloadWarningTrap signifies that the UPS
has detected an Overload condition where the output
load has exceeded the UPS's rated capacity. |
TRAP-TYPE |
|
|
|
lcUpsOverloadShutdownTrap |
2 |
An lcUpsOverloadShutdownTrap signifies that the
UPS has detected an Overload condition where the
output load has exceeded the UPS's rated capacity
and has shut off the output. |
TRAP-TYPE |
|
|
|
lcUpsOnBatteryTrap |
3 |
An lcUpsOnBatteryTrap signifies that the
UPS is currently on Battery Power. |
TRAP-TYPE |
|
|
|
lcUpsLowBatteryShutdownTrap |
5 |
An lcUpsLowBatteryShutdownTrap signifies that the
UPS has shut off the output due to a Low
Battery state. |
TRAP-TYPE |
|
|
|
lcUpsUtilPowerFailedTrap |
6 |
An lcUpsUtilPowerFailedTrap signifies that the
utility power input to the UPS has been lost. |
TRAP-TYPE |
|
|
|
lcUpsUtilPowerRestoredTrap |
7 |
An lcUpsUtilPowerRestoredTrap signifies that the
utility power has been restored to the UPS. |
TRAP-TYPE |
|
|
|
lcUpsOverTempWarningTrap |
9 |
An lcUpsOverTempWarningTrap signifies that the
UPS has detected a excessive temperature condition. |
TRAP-TYPE |
|
|
|
lcUpsOverTempShutdownTrap |
10 |
An lcUpsOverTempShutdownTrap signifies that the
UPS has detected a excessive temperature condition
and shut off the output. |
TRAP-TYPE |
|
|
|
lcUpsAlarmTrap |
11 |
An Alarm condition has occurred and is being reported
in the lcUpsAlarmTable. |
TRAP-TYPE |
|
|
|
lcUpsOutputOffTrap |
12 |
An lcUpsOutputOffTrap is sent when the UPS
turns all of its output off, either at the
inverter or via a relay. |
TRAP-TYPE |
|
|
|
lcUpsOutputOffWarningTrap |
13 |
An lcUpsOutputOffWarningTrap is sent when the
lcUpsControlOutputOffDelay reaches the value of
lcUpsControlOutputOffTrapDelay. |
TRAP-TYPE |
|
|
|
lcUpsOutputOnTrap |
14 |
An lcUpsOutputOnTrap is sent when the UPS
turns all of its output back on, either at the
inverter or via a relay. |
TRAP-TYPE |
|
|
|
lcUpsOutputOnWarningTrap |
15 |
An lcUpsOutputOnWarningTrap is sent when the
lcUpsControlOutputOnDelay reaches the value of
lcUpsControlOutputOnTrapDelay. |
TRAP-TYPE |
|
|
|
lcUpsUnixShutdownTrap |
16 |
An lcUpsUnixShutodwnTrap is sent 2 seconds before
the UPS is scheduled to perform a Unix Shutdown. |
TRAP-TYPE |
|
|
|
lcUpsUnixShutdownWarningTrap |
17 |
An lcUpsUnixShutdownWarningTrap is sent when the
lcUpsControlUnixShudownDelay reaches the value of
lcUpsControlUnixShutdownTrapDelay. |
TRAP-TYPE |
|
|
|
lcUpsDCOverVoltageShutdownTrap |
23 |
An lcUpsDCOverVoltageShutdownTrap signifies that
the UPS has detected that battery voltage is over
the tolarable level. |
TRAP-TYPE |
|
|
|
lcUpsOutputOverVoltageTrap |
24 |
An lcUpsOutputOverVoltageTrap signifies that the
UPS has detected that the output voltage is too high. |
TRAP-TYPE |
|
|
|
lcUpsFuseBlownTrap |
25 |
An lcUpsFuseBlownTrap is sent when the UPS's
rectifier or DC capacitor fuse has failed. |
TRAP-TYPE |
|
|
|
lcUpsEmergencyPowerOffTrap |
26 |
An lcUpsEmergencyPowerOffTrap signifies that
the UPS has shut off output due to an emergency
condition. |
TRAP-TYPE |
|
|
|
lcUpsReversePowerTrap |
28 |
An lcUpsReversePowerTrap signifies that output has been
shut off due to a reverse power flow condition. |
TRAP-TYPE |
|
|
|
lcUpsLoadOnBypassTrap |
30 |
An lcUpsLoadOnBypassTrap signifies that the load has
been transferred to bypass power. |
TRAP-TYPE |
|
|
|
lcUpsEmergencyXferToBypassTrap |
31 |
An lcUpsEmergencyXferToBypassTrap signifies that the UPS has
automatically tranferred the load to bypass power. |
TRAP-TYPE |
|
|
|
lcUpsInverterFaultTrap |
34 |
An lcUpsInverterFaultTrap signifies that the UPS
detected a problem with the Inverter. |
TRAP-TYPE |
|
|
|
lcUpsReceptOffTrap |
18 |
An lcUpsReceptOffTrap is sent when the UPS
turns an output receptacle off. |
TRAP-TYPE |
|
|
|
lcUpsReceptOffWarningTrap |
19 |
An lcUpsReceptOffWarningTrap is sent when the
lcUpsSwitchedReceptOffDelay reaches the value of
lcUpsSwitchedReceptOffTrapDelay. |
TRAP-TYPE |
|
|
|
lcUpsReceptOnTrap |
20 |
An lcUpsReceptOnTrap is sent when the UPS
turns an output receptacle on. |
TRAP-TYPE |
|
|
|
lcUpsReceptOnWarningTrap |
21 |
An lcUpsReceptOnWarningTrap is sent when the
lcUpsSwitchedReceptOnDelay reaches the value of
lcUpsSwitchedReceptOnTrapDelay. |
TRAP-TYPE |
|
|
|
lsUpsIdent |
1.3.6.1.4.1.476.1.1.1.2.1 |
OBJECT IDENTIFIER |
|
|
|
lsUpsAlarm |
1.3.6.1.4.1.476.1.1.1.2.6 |
OBJECT IDENTIFIER |
|
|
|
lsUpsTraps |
1.3.6.1.4.1.476.1.1.1.2.11 |
OBJECT IDENTIFIER |
|
|
|
lsUpsCheckAirFilterTrap |
1 |
An lsUpsCheckAirFilterTrap signifies that the programmed time
interval for checking the air filter has passed and it is time to
check the air filter. |
TRAP-TYPE |
|
|
|
lsUpsConfig |
1.3.6.1.4.1.476.1.1.1.2.12 |
OBJECT IDENTIFIER |
|
|
|
lsUpsConfigBypassInstalled |
1.3.6.1.4.1.476.1.1.1.2.12.1 |
Indicates if a bypass is installed in the UPS. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), yes(2), no(3) |
|
lsUpsBypass |
1.3.6.1.4.1.476.1.1.1.2.13 |
OBJECT IDENTIFIER |
|
|
|
lsUpsOnBypass |
1.3.6.1.4.1.476.1.1.1.2.13.1 |
Indicates that the UPS is currently on bypass. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), yes(2), no(3) |
|
lsUpsBypassFrequency |
1.3.6.1.4.1.476.1.1.1.2.13.2 |
The current bypass frequency. (Unit of measure:
Hertz) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lsUpsBypassNumLines |
1.3.6.1.4.1.476.1.1.1.2.13.3 |
The number of bypass lines utilized in this
device. This entry indicates the number of rows in
the bypass table. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..3 |
|
lsUpsBypassEntry |
1.3.6.1.4.1.476.1.1.1.2.13.4.1 |
Tok_String |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LsUpsBypassEntry |
|
|
lsUpsBypassLine |
1.3.6.1.4.1.476.1.1.1.2.13.4.1.1 |
The bypass Line. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..3 |
|
lsUpsBypassVoltage |
1.3.6.1.4.1.476.1.1.1.2.13.4.1.2 |
The bypass voltage. (Unit of measure: Volt) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lsUpsBypassCurrent |
1.3.6.1.4.1.476.1.1.1.2.13.4.1.3 |
The bypass current. (Unit of measure: Amp) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
ldUpsAlarm |
1.3.6.1.4.1.476.1.1.1.3.6 |
OBJECT IDENTIFIER |
|
|
|
ldUpsTraps |
1.3.6.1.4.1.476.1.1.1.3.11 |
OBJECT IDENTIFIER |
|
|
|
ldUpsDCOverVoltageShutdownTrap |
1 |
An ldUpsDCOverVoltageShutdownTrap signifies that
the UPS has detected that battery voltage is over
the tolarable level. |
TRAP-TYPE |
|
|
|
ldUpsOutputShortShutdownTrap |
2 |
An ldUpsOutputShortShutdownTrap signifies that
the UPS has detected a short circuit across the
output. |
TRAP-TYPE |
|
|
|
ldUpsLNReversedShutdownTrap |
3 |
An ldUpsLNReversedShutdownTrap signifies that
the UPS has detected that Line and Neutral have
been reversed. |
TRAP-TYPE |
|
|
|
ldUpsOutputOverVoltageTrap |
6 |
An ldUpsOutputOverVoltageTrap signifies that the
UPS has detected that the output voltage is too high. |
TRAP-TYPE |
|
|
|
ldUpsOutputUnderVoltageTrap |
7 |
An ldUpsOutputUnderVoltageTrap signifies that the
UPS has detected that the output voltage is too low. |
TRAP-TYPE |
|
|
|
ldUpsChargerFailedTrap |
8 |
An ldUpsChargerFailedTrap signifies that the UPS
has detected that the battery charger has failed. |
TRAP-TYPE |
|
|
|
ldUpsOutput |
1.3.6.1.4.1.476.1.1.1.3.4 |
OBJECT IDENTIFIER |
|
|
|
ldUpsOutputMaxVoltsSinceLastPoll |
1.3.6.1.4.1.476.1.1.1.3.4.1 |
The maximum output voltage encountered since the object was
last retrieved. Note: if there are multiple managers talking
to the same agent, the use of this object needs to be
coordinated. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
ldUpsOutputMinVoltsSinceLastPoll |
1.3.6.1.4.1.476.1.1.1.3.4.2 |
The minimum output voltage encountered since the object was
last retrieved. Note: if there are multiple managers talking
to the same agent, the use of this object needs to be
coordinated. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lgUpsAlarm |
1.3.6.1.4.1.476.1.1.1.4.6 |
OBJECT IDENTIFIER |
|
|
|
lgUpsTraps |
1.3.6.1.4.1.476.1.1.1.4.11 |
OBJECT IDENTIFIER |
|
|
|
lgUpsDCOverVoltageShutdownTrap |
1 |
An lgUpsDCOverVoltageShutdownTrap signifies that
the UPS has detected that battery voltage is over
the nominal level. |
TRAP-TYPE |
|
|
|
lgUpsOutputShortShutdownTrap |
2 |
An lgUpsOutputShortShutdownTrap signifies that
the UPS has detected a short circuit across the
output. |
TRAP-TYPE |
|
|
|
lgUpsLNReversedShutdownTrap |
3 |
An lgUpsLNReversedShutdownTrap signifies that
the UPS has detected that Line and Neutral have
been reversed. |
TRAP-TYPE |
|
|
|
luSeries200ConfigBypassInstalled |
1.3.6.1.4.1.476.1.1.1.8.12.1 |
Indicates if a bypass is installed in the UPS. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), yes(2), no(3) |
|
luSeries200ConfigFrequencyChangerModel |
1.3.6.1.4.1.476.1.1.1.8.12.2 |
Indicates whether this AP200 model is a frequency changer model. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), yes(2), no(3) |
|
luSeries200OnBypass |
1.3.6.1.4.1.476.1.1.1.8.13.1 |
Indicates that the UPS is currently on bypass. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), yes(2), no(3) |
|
ls43cUpsConfigBypassInstalled |
1.3.6.1.4.1.476.1.1.1.10.12.1 |
Indicates if a bypass is installed in the UPS. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), yes(2), no(3) |
|
ls43cUpsOnBypass |
1.3.6.1.4.1.476.1.1.1.10.13.1 |
Indicates that the UPS is currently on bypass. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), yes(2), no(3) |
|
ls43cUpsBypassFrequency |
1.3.6.1.4.1.476.1.1.1.10.13.2 |
The current bypass frequency. (Unit of measure:
Hertz) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
ls43cUpsBypassNumLines |
1.3.6.1.4.1.476.1.1.1.10.13.3 |
The number of bypass lines utilized in this
device. This entry indicates the number of rows in
the bypass table. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..3 |
|
ls43cUpsBypassEntry |
1.3.6.1.4.1.476.1.1.1.10.13.4.1 |
Tok_String |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ls43cUpsBypassEntry |
|
|
ls43cUpsBypassLine |
1.3.6.1.4.1.476.1.1.1.10.13.4.1.1 |
The bypass Line. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..3 |
|
ls43cUpsBypassVoltage |
1.3.6.1.4.1.476.1.1.1.10.13.4.1.2 |
The bypass voltage. (Unit of measure: Volt) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
ls43cUpsBypassCurrent |
1.3.6.1.4.1.476.1.1.1.10.13.4.1.3 |
The bypass current. (Unit of measure: Amp) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
luExternal |
1.3.6.1.4.1.476.1.1.1.6 |
OBJECT IDENTIFIER |
|
|
|