LANOPTICS-SYSTEM-MIB

File: LANOPTICS-SYSTEM-MIB.mib (14730 bytes)

Imported modules

RFC-1212 RFC1155-SMI RFC1213-MIB

Imported symbols

OBJECT-TYPE enterprises IpAddress
DisplayString

Defined Types

SnSysCMOSIpInterfaceEntry  
SEQUENCE    
  snSysCMOSIpIpAddr IpAddress
  snSysCMOSIpNetMask IpAddress

SnSysCMOSHubSlotConfigEntry  
SEQUENCE    
  snSysSlotLastOperations OCTET STRING
  snSysResetSlotQueue INTEGER

SnSysCMOSSNMPCommunitiesEntry  
SEQUENCE    
  snSysCMOSSNMPCommunityName DisplayString
  snSysCMOSSNMPCommunityPrivs INTEGER

SnSysCMOSSNMPTrapCommunitiesEntry  
SEQUENCE    
  snSysCMOSSNMPTrapCommunityIpAddr IpAddress

Defined Values

lanOptics 1.3.6.1.4.1.224
OBJECT IDENTIFIER    

lanOpticsSystem 1.3.6.1.4.1.224.2
OBJECT IDENTIFIER    

lanOpticsSystemCMOS 1.3.6.1.4.1.224.2.3
OBJECT IDENTIFIER    

lanOpticsSystemCMOSIp 1.3.6.1.4.1.224.2.3.1
OBJECT IDENTIFIER    

lanOpticsSystemCMOSHub 1.3.6.1.4.1.224.2.3.2
OBJECT IDENTIFIER    

lanOpticsSystemCMOSRPL 1.3.6.1.4.1.224.2.3.3
OBJECT IDENTIFIER    

lanOpticsSystemCMOSSerial 1.3.6.1.4.1.224.2.3.4
OBJECT IDENTIFIER    

lanOpticsSystemCMOSSRAM 1.3.6.1.4.1.224.2.3.5
OBJECT IDENTIFIER    

lanOpticsSystemCMOSSNMP 1.3.6.1.4.1.224.2.3.6
OBJECT IDENTIFIER    

lanOpticsSystemCMOSACCESS 1.3.6.1.4.1.224.2.3.7
OBJECT IDENTIFIER    

lanOpticsSystemCMOSBRDG 1.3.6.1.4.1.224.2.3.8
OBJECT IDENTIFIER    

snSysDirectory 1.3.6.1.4.1.224.2.1
Gives the agent directory content (make DOS DIR command on agent directory).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

snAgentVersion 1.3.6.1.4.1.224.2.2
Gives the agent major version in the high order word and the minor version in low order word.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

snSysCMOSIpInterfaceTable 1.3.6.1.4.1.224.2.3.1.1
A list of network interfaces.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnSysCMOSIpInterfaceEntry

snSysCMOSIpInterfaceEntry 1.3.6.1.4.1.224.2.3.1.1.1
An interface entry containing the Ipaddress and net-mask.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnSysCMOSIpInterfaceEntry  

snSysCMOSIpIpAddr 1.3.6.1.4.1.224.2.3.1.1.1.1
Gives the interface's IpAddress
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

snSysCMOSIpNetMask 1.3.6.1.4.1.224.2.3.1.1.1.2
Gives the interfaces's netmask
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

snSysCMOSIpDefGw 1.3.6.1.4.1.224.2.3.1.2
Gives the agent's default gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

snSysCMOSIpTFTPOp 1.3.6.1.4.1.224.2.3.1.3
Gives the TFTP policy: 1 - No TFTP, 2 - Optional, 3 - Always
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noTFTP(1), limited(2), continuous(3)  

snSysCMOSIpTFTPAddr 1.3.6.1.4.1.224.2.3.1.4
Gives the TFTP server Ip address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

snSysCMOSIpTFTPFileName 1.3.6.1.4.1.224.2.3.1.5
Gives the boot file name at the server (full path).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

snSysCMOSIpTFTPDrive 1.3.6.1.4.1.224.2.3.1.6
Gives the TFTP operation destination drive (value of ASCII character).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER driveA(41), driveB(42), driveC(43), driveD(44)  

snSysCMOSHubSlotConfigTable 1.3.6.1.4.1.224.2.3.2.1
A list of slots entries. Each entry in this table, contains the last 20 operations performed on the slot.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnSysCMOSHubSlotConfigEntry

snSysCMOSHubSlotConfigEntry 1.3.6.1.4.1.224.2.3.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnSysCMOSHubSlotConfigEntry  

snSysSlotLastOperations 1.3.6.1.4.1.224.2.3.2.1.1.1
A description of last 20 operations performed, on the slot
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

snSysResetSlotQueue 1.3.6.1.4.1.224.2.3.2.1.1.2
Resets the last 20 operations queue.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snSysCMOSHubSaveHubFunctions 1.3.6.1.4.1.224.2.3.2.2
Save (2) /Do not Save (1) Hub managment functions in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER not-saved(1), saved(2)  

snSysCMOSRPLMode 1.3.6.1.4.1.224.2.3.3.1
Determine if the image will be loaded through RPL at next boot: RPL off - 1, RPL on - 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rpl-off(1), rpl-on(2)  

snSysCMOSFlashMode 1.3.6.1.4.1.224.2.3.3.2
Determine if the image will be loaded from flash memory at next boot : flash on - 2, flash off - 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER flash-off(1), flash-on(2)  

snSysCMOSSerialMode 1.3.6.1.4.1.224.2.3.4.1
Determine the serial port usage mode : Proprietary - 1, SLIP - 2, None - 3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER proprietary(1), slip(2), none(3)  

snSysCMOSSerialComSelect 1.3.6.1.4.1.224.2.3.4.2
Determine which COM port is used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sr-COM1(1), sr-COM2(2)  

snSysCMOSSerialBaudRate 1.3.6.1.4.1.224.2.3.4.3
Determine the serial port baud rate : 1200 - 1, 2400 - 2, 4800 - 3, 9600 - 4, 19200 - 5, 38300 - 6, 57600 - 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud1200(1), baud2400(2), baud4800(3), baud9600(4), baud19200(5), baud38300(6), baud57600(7)  

snSysCMOSSerialWordLength 1.3.6.1.4.1.224.2.3.4.4
Determine the data bits length : 7 Bits - 1, 8 Bits -2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bits-7(1), bits-8(2)  

snSysCMOSSerialStopBits 1.3.6.1.4.1.224.2.3.4.5
Determine the number of stop bits; values allowed : 1 Bit - 1, 1.5 Bits - 2, 2 Bits - 3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bits-1(1), bits-15(2), bits-2(3)  

snSysCMOSSerialParityCheck 1.3.6.1.4.1.224.2.3.4.6
Determine the parity check policy : Even - 1, Odd - 2, None - 3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER even(1), odd(2), none(3)  

snSysCMOSSRAMKeepAliveSecInterval 1.3.6.1.4.1.224.2.3.5.1
Determine the interval of the keep alive frame in seconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snSysCMOSSNMPCommunitiesNum 1.3.6.1.4.1.224.2.3.6.1
Keeps the number of communities.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

snSysCMOSSNMPTrapManagersNum 1.3.6.1.4.1.224.2.3.6.2
Keeps the number of managers that traps are send to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

snSysCMOSSNMPCommunitiesTable 1.3.6.1.4.1.224.2.3.6.3
A table containing the SNMP communities
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnSysCMOSSNMPCommunitiesEntry

snSysCMOSSNMPCommunitiesEntry 1.3.6.1.4.1.224.2.3.6.3.1
An entry community info
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnSysCMOSSNMPCommunitiesEntry  

snSysCMOSSNMPCommunityName 1.3.6.1.4.1.224.2.3.6.3.1.1
This variable will give the community name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

snSysCMOSSNMPCommunityPrivs 1.3.6.1.4.1.224.2.3.6.3.1.2
This variable will give the community privilages: Read Only - 1, Read/Write - 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER read-Only(1), read-Write(2)  

snSysCMOSSNMPTrapCommunitiesTable 1.3.6.1.4.1.224.2.3.6.4
A table containing the SNMP communities
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnSysCMOSSNMPTrapCommunitiesEntry

snSysCMOSSNMPTrapCommunitiesEntry 1.3.6.1.4.1.224.2.3.6.4.1
An entry of trap IP destinations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnSysCMOSSNMPTrapCommunitiesEntry  

snSysCMOSSNMPTrapCommunityIpAddr 1.3.6.1.4.1.224.2.3.6.4.1.1
This variable gives a manager IP address for traps destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

snSysCMOSACCESSOffset 1.3.6.1.4.1.224.2.3.7.1
Gives the offset in the CMOS array. For internal use only
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snSysCMOSACCESSLength 1.3.6.1.4.1.224.2.3.7.2
Gives the length (max 512) in the CMOS array. For internal use only,
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snSysCMOSACCESSSequence 1.3.6.1.4.1.224.2.3.7.3
Gives a sequnce of bytes from CMOS array. For internal use only
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snSysCMOSBRDGradius 1.3.6.1.4.1.224.2.3.8.1
Sets the discovery radius. Value = 0-7. 0=disable bridge.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snSysCMOSBRDGlinkNumber 1.3.6.1.4.1.224.2.3.8.2
Sets the Link number. Value = 0-3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

snSysCMOSBRDGpassword 1.3.6.1.4.1.224.2.3.8.3
Sets the bridge password. 8 characters .
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString