LANNET-MIB

File: LANNET-MIB.mib (92246 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

NetworkAddress IpAddress Counter
Gauge TimeTicks enterprises
OBJECT-TYPE

Defined Types

StandardRelayEntry  
SEQUENCE    
  standardRelayID INTEGER
  standardRelayNumberOfGroups INTEGER
  standardRelayTotalCollisions Counter
  standardRelayReset INTEGER
  standardRelayCurTraffic STRING
  standardRelayTrafficTrsh INTEGER
  standardRelayPeakTraffic INTEGER

StandardGroupEntry  
SEQUENCE    
  standardGroupID INTEGER
  standardGroupNumberOfPorts INTEGER
  standardGroupAutoMan INTEGER
  standardGroupReset INTEGER

StandardPortEntry  
SEQUENCE    
  standardPortType INTEGER
  standardPortID INTEGER
  standardPortAdminStatus INTEGER
  standardPortAutoPartitionState INTEGER
  standardPortFramesReceivedOK Counter
  standardPortOctetsReceivedOK Counter
  standardPortCollisions Counter
  standardPortLateCollisions Counter
  standardPortFrameCheckSequence Counter
  standardPortSQETestNotDisabled INTEGER
  standardPortRunt Counter
  standardPortPygmy Counter
  standardPortOutOfRangeLenField Counter
  standardPortFramesTooLong Counter
  standardPortAlignmentErrors Counter
  standardPortAutoPartitionLog Counter
  standardPortOutOfSpecBitRate Counter
  standardPortLastSourceAddress STRING
  standardPortSourceAdressChanges Counter
  standardPortExecuteTest INTEGER
  standardPortTraffic Counter
  standardPortPacketErrors Counter
  standardPortUserStatus INTEGER
  standardPortGroupID INTEGER

MgrEntry  
SEQUENCE    
  mgrIPaddr IpAddress
  mgrMngmntState INTEGER
  mgrTrapRepStat INTEGER
  mgrContPerfornamceRep INTEGER

LntGroupEntry  
SEQUENCE    
  lntGroupHWVersion STRING
  lntGroupSWVersion STRING
  lntGroupKernelVersion STRING
  lntGroupType INTEGER
  lntGroupFIFO INTEGER
  lntGroupJabber INTEGER
  lntGroupBusPartition INTEGER
  lntGroupRedun12 INTEGER
  lntGroupRedun34 INTEGER
  lntGroup10BTPlus INTEGER
  lntGroupFullConfig STRING
  lntGroupAgentIfType INTEGER
  lntGroupAgentAddress STRING Size(0..15)
  lntGroupWrongPortSelection INTEGER
  lntGroupSupplyVoltageFault INTEGER
  lntGroupNumberOfIntPorts INTEGER 0..255
  lntGroupInPortsRedundancy INTEGER
  lntGroupStandAloneModeSwitch INTEGER
  lntGroupId INTEGER
  lntGroupDescr STRING
  lntGroupBackboneMode INTEGER
  lntGroupFOIRLPlusMode INTEGER
  lntGroupLATStatus INTEGER
  lntGroupInterProcCommStatus INTEGER
  lntGroupOperationMode INTEGER
  lntGroupCommunicationStatus INTEGER
  lntGroupHardwareStatus INTEGER

LntPortEntry  
SEQUENCE    
  lntPortType INTEGER
  lntPortJabber INTEGER
  lntPortNoAUILoop INTEGER
  lntPortFunctionalStatus INTEGER
  lntPortManPart INTEGER
  lntPortLinkTest INTEGER
  lntPortPeer INTEGER
  lntPortAgent INTEGER
  lntPortAgentAddr IpAddress
  lntPortActivityStatus INTEGER
  lntPortGroupId INTEGER
  lntPortId INTEGER
  lntPortDescr STRING
  lntPortIntPortConnection INTEGER

LntIntPortEntry  
SEQUENCE    
  lntIntPortGroupId INTEGER
  lntIntPortId INTEGER
  lntIntPortAdminStatus INTEGER
  lntIntPortActivityStatus INTEGER
  lntIntPortPartition INTEGER
  lntIntPortBusConnection INTEGER

TRGroupEntry  
SEQUENCE    
  trGroupID INTEGER
  trGroupNumberOfPorts INTEGER
  trGroupAutoMan INTEGER
  trGroupReset INTEGER
  trGroupHWVersion STRING
  trGroupSWVersion STRING
  trGroupKernelVersion STRING
  trGroupType INTEGER
  trGroupFullConfig STRING
  trGroupAutoRightLoop INTEGER
  trGroupAutoLeftLoop INTEGER
  trGroupManRightLoop INTEGER
  trGroupManLeftLoop INTEGER
  trGroupRightNeigbour INTEGER
  trGroupLeftNeigbour INTEGER
  trGroupIoMode INTEGER
  trGroupRingSpeed INTEGER
  trGroupTxLinkDown INTEGER
  trGroupRxLinkDown INTEGER
  trGroupManLinkLoop INTEGER
  trGroupManBusLoop INTEGER
  trGroupAutoLinkLoop INTEGER
  trGroupAutoBusLoop INTEGER
  trGroupIOModeF INTEGER
  trGroupDescr STRING
  trGroupAgentIfType INTEGER
  trGroupAgentAddress STRING Size(0..15)
  trGroupSecondRingSpeed INTEGER
  trGroupBridgeMode INTEGER
  trGroupFirstRingInserted INTEGER
  trGroupSecondRingInserted INTEGER
  trGroupStandAloneModeSwitch INTEGER
  trGroupRedun12 INTEGER
  trGroupRedun34 INTEGER
  trGroupSuperRedundancy INTEGER
  trGroupInterProcCommStatus INTEGER
  trGroupCommunicationStatus INTEGER
  trGroupHardwareStatus INTEGER

TRPortEntry  
SEQUENCE    
  trPortType INTEGER
  trPortID INTEGER
  trPortBypass INTEGER
  trPortConnected INTEGER
  trPortTcp INTEGER
  trPortCableFault INTEGER
  trPortGroupID INTEGER
  trPortDescr STRING
  trPortFunctionalStatus INTEGER
  trPortActivityStatus INTEGER

TrIntPortEntry  
SEQUENCE    
  trIntPortGroupId INTEGER
  trIntPortId INTEGER
  trIntPortBusConnection INTEGER
  trIntPortAdminStatus INTEGER

TrRingEntry  
SEQUENCE    
  trRingIndex INTEGER
  trRingCurTraffic STRING
  trRingTrafficTrsh INTEGER
  trRingPeakTraffic INTEGER

SRLPortEntry  
SEQUENCE    
  srlportGroupID INTEGER
  srlportID INTEGER
  srlportType INTEGER
  srlportAdminStatus INTEGER
  srlportDescr STRING

LTGroupEntry  
SEQUENCE    
  ltGroupID INTEGER
  ltGroupNumberOfPorts INTEGER
  ltGroupAutoMan INTEGER
  ltGroupReset INTEGER
  ltGroupHWVersion STRING
  ltGroupSWVersion STRING
  ltGroupKernelVersion STRING
  ltGroupType INTEGER
  ltGroupFullConfig STRING
  ltGroupDescr STRING
  ltGroupInterProcCommStatus INTEGER
  ltGroupStandAloneModeSwitch INTEGER
  ltGroupCommunicationStatus INTEGER

LTPortEntry  
SEQUENCE    
  ltPortGroupID INTEGER
  ltPortID INTEGER
  ltPortType INTEGER
  ltPortAdminStatus INTEGER
  ltPortTest INTEGER
  ltPortTestResult INTEGER
  ltPortJam INTEGER
  ltPortDescr STRING

LTIntPortEntry  
SEQUENCE    
  ltIntPortGroupId INTEGER
  ltIntPortId INTEGER
  ltIntPortAdminStatus INTEGER
  ltIntPortBusConnection INTEGER

Defined Values

lannet 0.1.81
OBJECT IDENTIFIER    

lntStandard 0.1.81.1
OBJECT IDENTIFIER    

standardHub 0.1.81.1.1
OBJECT IDENTIFIER    

standardHubID 0.1.81.1.1.1
A 48-bit unique identifier of the hub. Not to be confused with the 48-bit address of the MAC that may be used to obtain management access to the hub when in-band signaling is used. If a manufacturer builds a hub with an on-board MAP for communicating network management information, the manufacturer has the option to use the same address for both HubID and MAC address. This option is implemented by LANNET agents for LET-18 and LET- 36.
OBJECT-TYPE    
  STRING  

standardHubElapsedTimeSinceRest 0.1.81.1.1.2
The time in tens of milliseconds since the last time the hub was reset. This may have been caused by a RESET HUB action or by other means. This counter has a value of 0 when initialized. Setting the value of this attribute to zero is interpreted by LANNET agents as a RESET commnand. The required resolution is to the nearest 100 milliseconds.
OBJECT-TYPE    
  TimeTicks  

standardHubExecuteSelfTest1 0.1.81.1.1.3
Perform self-test 1 on the hub. When this attribute is set to ON by the management console, the agent starts executing the hub test procedure. The attribute is reset to OFF at the end of the test procedure.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

standardHubExecuteSelfTest2 0.1.81.1.1.4
Perform self test 2 on the hub. When this attribute is set to ON by the management console, he agent starts executing the hub test procedure. The attribute is reset to OFF at the end of the test procedure.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

standardRelayTable 0.1.81.1.2
OBJECT-TYPE    
  SEQUENCE OF  
    StandardRelayEntry

standardRelayID 0.1.81.1.2.1
The value used in addressing the relay. Value 1 is returned by LANNET SNMP agents for hubs LE-18 and LET-36
OBJECT-TYPE    
  INTEGER  

standardRelayNumberOfGroups 0.1.81.1.2.2
Number of groups related to relay. Range 1-255. In LANNET implementation it describes the number of manageable slots in the hub (not all slots should be ocuppied).
OBJECT-TYPE    
  INTEGER  

standardRelayTotalCollisions 0.1.81.1.2.3
Counter incremented every time the hub enters a condition caused by simultaneous transmission and detection of external activity on one or more of its ports.
OBJECT-TYPE    
  Counter  

standardRelayReset 0.1.81.1.2.4
Setting the value of this attribute to ON is interpreted as a relay reset command, which leads to the zeroing of all relay-related counters.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

standardRelayCurTraffic 0.1.81.1.2.5
Record of traffic for the last second with a resolution of 100 msec. The traffic is expressed in percents of the maximum Ethernet traffic and each record contains 10 readings, in the range 1..20, expressed on a log(10) scale ( value = 10*log10(percent) ).
OBJECT-TYPE    
  STRING  

standardRelayTrafficTrsh 0.1.81.1.2.6
Traffic threshold value. When exceeded, a trap is send to the management console. Expressed in percents of the maximum Ethernet traffic, in the range 1..20, expressed on a log(10) scale.
OBJECT-TYPE    
  INTEGER  

standardRelayPeakTraffic 0.1.81.1.2.7
Maximal traffic value since last reset of hub or relay. Expressed in per- cents of the maximum Ethernet traffic, in the range 1..20, expressed on log(10) scale.
OBJECT-TYPE    
  INTEGER  

standardGroupTable 0.1.81.1.3
OBJECT-TYPE    
  SEQUENCE OF  
    StandardGroupEntry

standardGroupID 0.1.81.1.3.1
Unique value identifying the group. In LANNET enclosures it equals the slot number of the related module (FRU).
OBJECT-TYPE    
  INTEGER  

standardGroupNumberOfPorts 0.1.81.1.3.2
Number of ports contained within the group. Valid range 1..255. Within each group the ports are assigned unique numbers range from 1 to standardGroupNumberOfPorts. They correspond to the number of ports in the module (FRU).
OBJECT-TYPE    
  INTEGER  

standardGroupAutoMan 0.1.81.1.3.3
This attribute reflects the status of the AUTO/MANual switch which defi- nes the working mode of LANNET sensors. In the Manual mode, no set operations may be performed on attributes related to the sensor. The sensor works accor- ding to configuration switches set in hardware and transmits all the configuration information to the agent. In the Auto, mode hardware switches are overridden by set commands.
OBJECT-TYPE    
  INTEGER man(0), auto(1)  

standardGroupReset 0.1.81.1.3.4
Setting the value of this attribute to ON is interpreted as a software RESET command. Sensor software is reinitialized and according to the sensor specifications, partial or total reset of the module hardware may be performed.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

standardPortTable 0.1.81.1.4
OBJECT-TYPE    
  SEQUENCE OF  
    StandardPortEntry

standardPortType 0.1.81.1.4.1
Describes the port type from the point of view of its network functionali- ty. This characterization describes adherence to physical layer standards, while LANNET standard extensions are generally defined as private.
OBJECT-TYPE    
  INTEGER private(0), repeaterAUI(1), repeaterThin(2), repeater10BaseT(3), tenBaseFSyncAct(4), foirl(5), xcvr(6), lobe(7), ri(8), ro(9), serial(10), localTalk(11)  

standardPortID 0.1.81.1.4.2
A value unique in each group. It is assumed that ports are partitioned into groups that also have IDs and are related to FRUs. This value can never exceed standardGroupNumberOfPorts. Range 0..255.
OBJECT-TYPE    
  INTEGER  

standardPortAdminStatus 0.1.81.1.4.3
A disabled port neither transmits nor receives. The port must be explici- tenly enabled to restore operation. standardPortAdminStatus takes precedence over AutoPartition.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

standardPortAutoPartitionState 0.1.81.1.4.4
The AutoPart condition indicates that the port is currently partitioned by the auto-partition protection mechanism.
OBJECT-TYPE    
  INTEGER notAutoPart(0), autoPart(1)  

standardPortFramesReceivedOK 0.1.81.1.4.5
A representation of the total number of frames of legal length that have not been corrupted in transmission. These frames can be encoded and decoded by the commonly available MACs and provide a measure of the network bandwidth being used. The number does not include frames received with frame-too-long, FCS, alignment errors, frames lost due to internal MAC sublayer errors, runts or pygmys.
OBJECT-TYPE    
  Counter  

standardPortOctetsReceivedOK 0.1.81.1.4.6
Counter for the number of data and padding octets contained in the FramesReceivedOK counter.
OBJECT-TYPE    
  Counter  

standardPortCollisions 0.1.81.1.4.7
Counter incremented every time the hub enters a condition caused by simultaneous transmission and detection of external activity on this port.
OBJECT-TYPE    
  Counter  

standardPortLateCollisions 0.1.81.1.4.8
OBJECT-TYPE    
  Counter  

standardPortFrameCheckSequence 0.1.81.1.4.9
Counter for the number of frames received on this port that are an integral number of octets in length and do not pass the FCS check.
OBJECT-TYPE    
  Counter  

standardPortSQETestNotDisabled 0.1.81.1.4.10
Settable attribute which allows activation of SQE test for LANNET integrated transceivers.
OBJECT-TYPE    
  INTEGER disabled(0), notDisabled(1)  

standardPortRunt 0.1.81.1.4.11
Counter for the number of collision fragments longer than a pygmy and shorter than a legal packet, detected on this port.
OBJECT-TYPE    
  Counter  

standardPortPygmy 0.1.81.1.4.12
Counter for the number of pygmy fragments received on this port. These fragments, less than 64 +/- 10 bits long, may indicate an external noise hit, a network problem.
OBJECT-TYPE    
  Counter  

standardPortOutOfRangeLenField 0.1.81.1.4.13
Counter for the number of packets received on this port whose length field indicate values greater than 2 ** 15 . Such packets gene- rally do not point to a network problem, but merely to the use of the IEEE 802.3 protocol instead of Ethernet, in which case the field has a different significance - protocol type. It may be used for counting the number of frames transmitted in each protocol.
OBJECT-TYPE    
  Counter  

standardPortFramesTooLong 0.1.81.1.4.14
Counter for the number of packets received on this port that are longer than 1518 octets, yet do not exceed the maximum range for the range field.
OBJECT-TYPE    
  Counter  

standardPortAlignmentErrors 0.1.81.1.4.15
Counter for the number of frames received though this port that are not an integral number of octets in length. Although these frames will not pass the FCS check, they are not counted as FCS errors, as the alignment errors have precedence in the standard error counting scheme.
OBJECT-TYPE    
  Counter  

standardPortAutoPartitionLog 0.1.81.1.4.16
Counter for the number of times the repeater has automatically partitio- ned this port.
OBJECT-TYPE    
  Counter  

standardPortOutOfSpecBitRate 0.1.81.1.4.17
Counter for the number of times a packet has been received by this port with the transmission frequency (data rate) detectable out of spec.
OBJECT-TYPE    
  Counter  

standardPortLastSourceAddress 0.1.81.1.4.18
Ethernet source address of the last readable frame received by this port.
OBJECT-TYPE    
  STRING  

standardPortSourceAdressChanges 0.1.81.1.4.19
Counter for the number of times the last source address has changed.
OBJECT-TYPE    
  Counter  

standardPortExecuteTest 0.1.81.1.4.20
Setting to the value of this attribute to ON (determines the port to enter) self-test mode.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

standardPortTraffic 0.1.81.1.4.21
Counter for the number of bits received on this port in frames with legal length information.
OBJECT-TYPE    
  Counter  

standardPortPacketErrors 0.1.81.1.4.22
Counter for the number of frames with errors detected on the port by the LANNET agent hardware. This generic port error comprises too long packets, CRC and alignment errors.
OBJECT-TYPE    
  Counter  

standardPortUserStatus 0.1.81.1.4.23
Attribute defining the connection of a port to a single Ethernet source or to a multi-source (segment or star).
OBJECT-TYPE    
  INTEGER singleUser(1), multiUser(2)  

standardPortGroupID 0.1.81.1.4.24
ID of group which contains the port
OBJECT-TYPE    
  INTEGER  

lntSpecific 0.1.81.2
OBJECT IDENTIFIER    

mgrTable 0.1.81.2.1
OBJECT-TYPE    
  SEQUENCE OF  
    MgrEntry

mgrIPaddr 0.1.81.2.1.1
IP address of the network management console.
OBJECT-TYPE    
  IpAddress  

mgrTrapRepStat 0.1.81.2.1.2
ON indicates that SNMP agent should send SNMP traps (relay traffic ex- cluded) to the manager.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

mgrContPerformanceRep 0.1.81.2.1.3
ON indicates that the SNMP agent should send relay traffic SNMP traps to the manager.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

mgrMngmntState 0.1.81.2.1.4
Attribute to be set by manager in order to instruct the agent to enter into a management session with the console. Setting this value to ON has the effect of performing an 'I am your manager' action upon the agent.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

swLoad 0.1.81.2.2
OBJECT IDENTIFIER    

swLoadInit 0.1.81.2.2.1
Sensors software download procedure initialization message. Includes spe- cific information about the download procedure, such as type of target sen- sor, number of blocks, version.
OBJECT-TYPE    
  STRING  

swLoadSWBlock 0.1.81.2.2.2
Block of sensor software.
OBJECT-TYPE    
  STRING  

lntHubAgent 0.1.81.2.3
OBJECT IDENTIFIER    

lntHubAgentSWFault 0.1.81.2.3.1
Generic fault emitted by agent software. It generally covers all types of faults which cannot be transmitted by the standard types of generic SNMP traps. Uses EnterpriseSpecific traps mechanism.
OBJECT-TYPE    
  STRING  

lntHubAgentEthernetAddr 0.1.81.2.3.2
Hub agent Ethernet Address - used in previous implementations. Today replaced by interface address in standard MIB II.
OBJECT-TYPE    
  STRING  

lntHubAgentHWVersion 0.1.81.2.3.3
ASCII string for description and display of the agent hardware version, as known to the agent software.
OBJECT-TYPE    
  STRING  

lntHubAgentSWVersion 0.1.81.2.3.4
ASCII string for description and display of the agent software version.
OBJECT-TYPE    
  STRING  

lntHubAgentKernelVersion 0.1.81.2.3.5
ASCII string for description and display of the agent operating system (kernel) version.
OBJECT-TYPE    
  STRING  

lntHubAgentFullConfig 0.1.81.2.3.6
Full configuration message sent by agent upon enrollment and at periodic interrogation times. Coded in internal LANNET application format. Up to release 1.5, this attribute was trasmitted to the management console by generic EnterpriseSpecific traps. Starting with release 2.0, it is retrieved by means of Get interogations.
OBJECT-TYPE    
  STRING  

lntHubAgentPerfBusSelection 0.1.81.2.3.7
Attribute describing the bus attached to the performance data collection hardware on those LANNET agent hardware implementations which support configuration management on multi-Ethernet bus enclosures, but performan- ce data collection on a single bus.
OBJECT-TYPE    
  INTEGER  

lntHubAgentLastAddressConfig 0.1.81.2.3.8
Configuration attribute describing the last physical address detected at each Ethernet port. Coded in internal LANNET application format.
OBJECT-TYPE    
  STRING  

lntHubAgentMgmtBusSelection 0.1.81.2.3.9
Attribute describing the bus attached to the performance data collection hardware on those LANNET agent hardware implementations which support configuration management on multi-Ethernet bus enclosures, but performan- ce data collection on a single bus.
OBJECT-TYPE    
  INTEGER  

lntHubAgentSLIPIpAddress 0.1.81.2.3.10
IP address of the SLIP channel of the agent
OBJECT-TYPE    
  IpAddress  

lntHubAgentType 0.1.81.2.3.11
Agent type.
OBJECT-TYPE    
  INTEGER nma1-et(1), nma1-etd(2), nma1-tr(3), nma2-et(4), nma2-tr(5)  

lntHubAgentHC11CommunicationStatus 0.1.81.2.3.12
Attribute describing the status of the communication with the Master HC11 as detected by the Agent software.
OBJECT-TYPE    
  INTEGER ok(1), commProblems(2), timeout(3)  

lntHubAgentCommunicationDebugMode 0.1.81.2.3.13
Attribute describing the agent mode in which communication problem traps are sent to managers (value on) or are not sent to managers (value off).
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntHubHW 0.1.81.2.4
OBJECT IDENTIFIER    

lntHubHWInternalTemp 0.1.81.2.4.1
Internal enclosure temperature expressed in degrees Celsius.
OBJECT-TYPE    
  INTEGER  

lntHubHWExternalTemp 0.1.81.2.4.2
External enclosure temperature expressed in degrees Celsius.
OBJECT-TYPE    
  INTEGER  

lntHubHWInternalPower 0.1.81.2.4.3
Value EXIST of this attribute signifies existence of an internal power supply on hardware configurations which may contain two (external and internal) power supply units.
OBJECT-TYPE    
  INTEGER none(0), exist(1)  

lntHubHWExternalPower 0.1.81.2.4.4
Value EXIST of this attribute signifies existence of an external power sup- ply on hardware configurations which may contain two (external and internal) power supply units.
OBJECT-TYPE    
  INTEGER none(0), exist(1)  

lntHubHWMainPower 0.1.81.2.4.5
This attribute defines the main power supply (internal or external) on hardware configurations represented upon the model of 2 (external and internal) power supply units.
OBJECT-TYPE    
  INTEGER internal(0), external(1)  

lntHubHWCoolingFan 0.1.81.2.4.6
Value ON of this attribute indicates operation of a cooling fan in the enclosure.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntHubHWType 0.1.81.2.4.7
Indicates type of enclosure in which the LANNET SNMP agent operates.
OBJECT-TYPE    
  INTEGER unknown(0), let18(1), let3(2), let36(3), let18Dual(4)  

lntHubHWNumberOfEthernetBuses 0.1.81.2.4.8
Indicates the number of internal Ethernet buses provided by the box.
OBJECT-TYPE    
  INTEGER  

lntHubHWNumberOfTRBuses 0.1.81.2.4.9
Indicates the number of internal Token Ring buses provided by the box.
OBJECT-TYPE    
  INTEGER  

lntHubHWNumberOfFDDIBuses 0.1.81.2.4.10
Indicates the number of internal FDDI buses provided by the box.
OBJECT-TYPE    
  INTEGER  

lntRelay 0.1.81.2.5
OBJECT IDENTIFIER    

lntGroupTable 0.1.81.2.6
OBJECT-TYPE    
  SEQUENCE OF  
    LntGroupEntry

lntGroupHWVersion 0.1.81.2.6.1
ASCII string for description and display of the sensor hardware version, as it is known to the agent software.
OBJECT-TYPE    
  STRING  

lntGroupSWVersion 0.1.81.2.6.2
ASCII string for description and display of the sensor application soft- ware version .
OBJECT-TYPE    
  STRING  

lntGroupKernelVersion 0.1.81.2.6.3
ASCII string for description and display of the sensor kernel software version.
OBJECT-TYPE    
  STRING  

lntGroupType 0.1.81.2.6.4
Attribute describing the type of LANNET Ethernet group.
OBJECT-TYPE    
  INTEGER unknown(0), le10b(1), le10b-2(2), le10c(3), le10c-2(4), le15(5), le15-2(6), le20(7), le30x(8), le30x-2(9), le30xd(10), le40x(11), le40xt(12), le10b-2r(25), le10c-2r(26), le80xt(27), le140xt(28), ielb(29), lts16(32), le20n(33), le20r(35), le20s(37), le10b2n(38)  

lntGroupFIFO 0.1.81.2.6.5
Value ON of this attribute describes an internal FIFO error sensed by the internal hardware mechanism of a LANNET repeater.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupJabber 0.1.81.2.6.6
Value ON of this attribute reflects jabber being transmitted to the bus by the hardware of a LANNET repeater, as a result of collisions detec- ted on the internal bus of the enclosure. Valid for modules LE-10 (all types) and LE-40XT.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupBusPartition 0.1.81.2.6.7
The AutoPart condition indicates that a LANNET repeater is currently par- titioned from the internal bus by the auto-partition mechanism. Valid for all types of LE-10 modules.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupRedun12 0.1.81.2.6.8
Value ON of this attribute defines a redundancy (backup) relationship between synchronous external ports 1 and 2 on a LANNET module. Valid for modules LE-10B-2, LE-10C-2, LE-20, LE-30X, LE-30X-2, LE-30XD, LE-40X, LE-40XT, LE-80XT, LE-140XT.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupRedun34 0.1.81.2.6.9
Value ON of this attribute defines a redundancy (backup) relationship between synchronous external ports 3 and 4 on a LANNET module. Valid for modules LE-30X, LE-30XD, LE-40X, LE-40XT.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroup10BTPlus 0.1.81.2.6.10
Value ON of this attribute defines activation of the 10BaseT+ mode of one of the LE-40XT, LE-80XT, LE-140XT modules. 10BaseT+ is a LANNET exten- sion of the 10BaseT standard.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupFullConfig 0.1.81.2.6.11
Attribute describing the full configuration of a group, in internal LANNET application format.
OBJECT-TYPE    
  STRING  

lntGroupAgentIfType 0.1.81.2.6.12
This attribute describes the interfaces of agents eventually existing on LANNET modules and their type. Value none defines the lack of an agent or of an interface recognized by the management console. Any other value defines an interface whose type is recognized by the management console and may be used as a management channel.
OBJECT-TYPE    
  INTEGER none(1), regular1822(2), hdh1822(3), ddn-x25(4), rfc877-x25(5), ethernet-csmacd(6), iso88023-csmacd(7), iso88024-tokenBus(8), iso88025-tokenRing(9), iso88026-man(10), starLan(11), proteon-10MBit(12), proteon-80MBit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), t1-carrier(18), cept(19), basicIsdn(20), primaryIsdn(21), propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), ethernet-3Mbit(26), nsip(27), slip(28), ip(255)  

lntGroupAgentAddress 0.1.81.2.6.13
This attribute defines an unique address by which the agent may be addres- sed by the management console. The address format should be consistent with the type defined by lntGroupAgentIfType.
OBJECT-TYPE    
  STRING  

lntGroupWrongPortSelection 0.1.81.2.6.14
A value ON of this attribute warns of incorrect selection of enabled ports on sensors which impose restrictions on this configura- tion (e.g. integrated local bridges.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupSupplyVoltageFault 0.1.81.2.6.15
A value ON of this attribute informs of a 'voltage supply out-of-range' error candition on sensor hardware which checks this condition.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupNumberOfIntPorts 0.1.81.2.6.16
Number of internal ports (ports connected to the enclosure buses) on the sensor.
OBJECT-TYPE    
  INTEGER 0..255  

lntGroupInPortsRedundancy 0.1.81.2.6.17
Value ON of this attribute defines a redundancy (backup) relationship between internal ports 1 and 2 on a LANNET module.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupStandAloneModeSwitch 0.1.81.2.6.18
Value ON of this attribute indicates the sensor's operation Stand Alone mode . Internal ports are disabled and the card functions in a local star configuration toward its external ports.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupId 0.1.81.2.6.19
Unique ID number for the group in the lntGroupTable.
OBJECT-TYPE    
  INTEGER  

lntGroupDescr 0.1.81.2.6.20
Descriptor of the group in ASCII (readable) format, mainly for use with generic management applications.
OBJECT-TYPE    
  STRING  

lntGroupBackboneMode 0.1.81.2.6.21
Value On of this attribute defines Backbone Mode of a sensor. Internal ports are enabled and the information path goes straightly from external port to internal bus, via corresponding internal port.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupFOIRLPlusMode 0.1.81.2.6.22
Value On of this attribute defines FOIRL of a sensor. When this attribute has value ON, FOIRL Plus mode is enabled, while value OFF indicates stan- dard FOIRL mode.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupLATStatus 0.1.81.2.6.23
Value ON of this attribute means that LAT protocol is Enabled on the LANNET Ethernet module.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntGroupInterProcCommStatus 0.1.81.2.6.24
This attribute describes the status of the communication between the microprocessor of the sensor and the microprocessor of the agent on cards with embedded agents.
OBJECT-TYPE    
  INTEGER ok(1), commProblems(2), noCommunication(3)  

lntGroupOperationMode 0.1.81.2.6.25
This attribute describes the operation mode of the module in a multiprocessor configuration sensor, as reported by interprocessors communication.
OBJECT-TYPE    
  INTEGER diagnostics(1), diagnosticsFailure(2), loading(3), loadingFailure(4), operational(5)  

lntGroupCommunicationStatus 0.1.81.2.6.26
This attribute describes the communication status of the group with the SNMP Agent as detected and reported by the agent.
OBJECT-TYPE    
  INTEGER ok(1), commProblems(2)  

lntGroupHardwareStatus 0.1.81.2.6.27
This attribute describes the status of the group hardware as detected by the sensors software.
OBJECT-TYPE    
  INTEGER ok(1), hardwareProblems(2)  

lntPortTable 0.1.81.2.7
OBJECT-TYPE    
  SEQUENCE OF  
    LntPortEntry

lntPortType 0.1.81.2.7.1
Attribute describing the type of LANNET port.
OBJECT-TYPE    
  INTEGER unknownPort(0), le10bPort(1), le10cPort(2), le15Port(3), le20Port(4), le30xPort(5), le30xdPort(6), le40xPort(7), le40xtPort(8), le80xtPort(27), le140xtPort(28), ielb-AUIPort(29), ielb-10btPort(30), le20rPort(35), le10bnPort(40)  

lntPortJabber 0.1.81.2.7.2
Value ON of this attribute reflects jabber transmitted to the port by the hardware of a LANNET repeater or transceiver, as a result of collisions detected on the port. Valid for all modules in the LE-10 and LE-15 families.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntPortNoAUILoop 0.1.81.2.7.3
Value ON of this attribute indicates that a No AUI Loop fault condition was detected on an AUI repeater port. Valid for LE-10C family of modu- les.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntPortFunctionalStatus 0.1.81.2.7.4
The value of this attribute reflects the functional status of LANNET synchronous ports. Note that it is not mandatory that all ports support all the enumerated states. Here is the minimal set possible states: OK - fully functional port, transmitting and receiving packets. RLD - receive link down condition on the port. TLD - transmit link down condition on the port. LocalJabber - fault condition indicating that the port emitted jabber. RemoteJabber - fault condition indicating that remote jabber was sensed at the port. IllSeq - Fault condition indicating an illegal synchronization sequence at the port. ShortCircuit - short-circuit fault condition detected at the port.
OBJECT-TYPE    
  INTEGER ok(0), rld(1), localJabber(2), tld(3), remoteJabber(4), illSeq(5), shortCirq(6)  

lntPortManPart 0.1.81.2.7.5
Setting to the value of this attribute to ON activates the manual partition mechanism at the port level. Setting the value of this attribute to OFF cancels the partition sechanism. The segment may reconnect after the reception of 32 packets. Attribute vaild for repeater modules from the LE-10 family.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntPortLinkTest 0.1.81.2.7.6
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntPortPeer 0.1.81.2.7.7
OBJECT-TYPE    
  INTEGER noPeer(0), xcvrOn(1), xcvrOff(2), hubOn(3), hubOff(4), notAvailable(5)  

lntPortAgent 0.1.81.2.7.8
OBJECT-TYPE    
  INTEGER none(0), exist(1)  

lntPortAgentAddr 0.1.81.2.7.9
OBJECT-TYPE    
  IpAddress  

lntPortActivityStatus 0.1.81.2.7.10
This attribute defines the status of ports that may be part of a redundan- cy scheme. NotActive - indicates a disabled port which cannot transmit or receive pac- kets even if included in a redundancy scheme. Dormant - indicates an enabled port which does not transmit or receive pac- kets, but because it is included in a redundancy scheme, it may at any moment become responsible packet transmission and reception. Active - indicates that the port transmits and receives packets, serving as the main path in the redundant configuration.
OBJECT-TYPE    
  INTEGER notActive(1), dormant(2), active(3)  

lntPortGroupId 0.1.81.2.7.11
Id of the group to which the port belongs.
OBJECT-TYPE    
  INTEGER  

lntPortId 0.1.81.2.7.12
Unique Id of the port in the lntPortTable.
OBJECT-TYPE    
  INTEGER  

lntPortDescr 0.1.81.2.7.13
Descriptor of the port in ASCII (readable) format, mainly for use with generic management applications.
OBJECT-TYPE    
  STRING  

lntPortIntPortConnection 0.1.81.2.7.14
The value of this attribute defines the internal port to which the port is connected.
OBJECT-TYPE    
  INTEGER 0..255  

lntIntPortTable 0.1.81.2.8
OBJECT-TYPE    
  SEQUENCE OF  
    LntIntPortEntry

lntIntPortEntry 0.1.81.2.8.1
OBJECT-TYPE    
  LntIntPortEntry  

lntIntPortGroupId 0.1.81.2.8.1.1
ID of the group to which the internal port belongs.
OBJECT-TYPE    
  INTEGER 0..255  

lntIntPortId 0.1.81.2.8.1.2
ID of the internal port in the lntPortTable.
OBJECT-TYPE    
  INTEGER 0..255  

lntIntPortAdminStatus 0.1.81.2.8.1.3
A disabled internal port neither transmits or receives. The port must be explicitly enabled to restore operation.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

lntIntPortActivityStatus 0.1.81.2.8.1.4
This attribute defines the status of internal ports that may be part of a redundancy scheme. NotActive - indicates a disabled port which cannot transmit or receive pac- kets even if included in a redundancy scheme. Dormant - indicates an enabled port which does not transmit or receive pac- kets, but because it is included in a redundancy scheme, it may at any moment become responsible for packet transmission and reception. Active - indicates that the port transmits and receives packets, serving as the main path in the redundant configuration.
OBJECT-TYPE    
  INTEGER notActive(1), dormant(2), active(3)  

lntIntPortPartition 0.1.81.2.8.1.5
This condition indicates that the internal port is currently partitioned from the bus by the auto-partition protection mechanism.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

lntIntPortBusConnection 0.1.81.2.8.1.6
The value of this attribute defines the bus to which the internal port is connected. Internal Ethernet buses are numbered 1 and 2 in LET-18 enclosures and 1 to 4 in LET-36 enclosures.
OBJECT-TYPE    
  INTEGER 0..255  

trSpecific 0.1.81.3
OBJECT IDENTIFIER    

trGroupTable 0.1.81.3.1
OBJECT-TYPE    
  SEQUENCE OF  
    TRGroupEntry

trGroupID 0.1.81.3.1.1
Unique ID of the group in trGroupTable. Equivalent to slot number in LANNET enclosures.
OBJECT-TYPE    
  INTEGER  

trGroupNumberOfPorts 0.1.81.3.1.2
Number of ports in group. Range 1..255. It is assumed that on each group the ports are assigned unique numbers in the range from 1 to TRGroupNumberOfPorts. They correspond to the number of ports on the module (FRU)
OBJECT-TYPE    
  INTEGER  

trGroupAutoMan 0.1.81.3.1.3
This attribute reflects the status of the Auto/Manual switch which defines the working mode of LANNET sensors. In the MANUAL mode no set operations may be performed on attributes related to the sensor. The sensor works according to configuration switches set by hardware and transmits all configuration information to the agent. In the AUTO mode, hardware switches are overridden by set commands.
OBJECT-TYPE    
  INTEGER man(0), auto(1)  

trGroupReset 0.1.81.3.1.4
Setting the value of this attribute to ON is interpreted as a software RESET command. Sensor software is reinitialised and acording to the sensor specifications, partial or total reset of the module hardware may be performed.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupHWVersion 0.1.81.3.1.5
ASCII string for description and display of the sensor hardware version, as it is known to the agent software.
OBJECT-TYPE    
  STRING  

trGroupSWVersion 0.1.81.3.1.6
ASCII string for description and display of the sensor application soft- ware version.
OBJECT-TYPE    
  STRING  

trGroupKernelVersion 0.1.81.3.1.7
ASCII string for description and display of the sensor kernel software version.
OBJECT-TYPE    
  STRING  

trGroupType 0.1.81.3.1.8
Attribute describing the type of LANNET token ring group.
OBJECT-TYPE    
  INTEGER ltr4-RJ45(13), ltr4-D9(14), ltr4-D25(15), ltr4-FO(16), ltrio-RJ45(19), ltrio-D9(20), ltrio-D25(21), ltrio-FO(22), ltrio-Con1(23), ltrio-Con2(24), ltrf4(30), ltrf16(31), ltr104-RJ45(34), ltr104-D9(39), ltr104-D25(40), ltrt-RJ45(41), ltrt-D9(42), ltr104f(43), itlb(44)  

trGroupFullConfig 0.1.81.3.1.9
Attribute describing the full configuration of a token ring group in in- ternal LANNET application format.
OBJECT-TYPE    
  STRING  

trGroupAutoRightLoop 0.1.81.3.1.10
Value ON of this attribute signifies that a hardware loop was automatically created on a Token Ring module which does not sense the existence of another token ring group on the right hand side.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupAutoLeftLoop 0.1.81.3.1.11
Value ON of this attribute signifies that a hardware loop was automatically created on a Token Ring module which does not sense the existence of another token ring group on the left hand side.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupManRightloop 0.1.81.3.1.12
Setting this attribute to ON signifies a command to the hardware to create a loop on the Token Ring module which isolates the ring from the right hand side.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupManLeftLoop 0.1.81.3.1.13
Setting this attribute to ON signifies a command to the hardware to create a loop on the Token Ring module which isolates the ring from the left hand side.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupRightNeigbour 0.1.81.3.1.14
Attribute defining the existence of a neighbor another token ring group on the right hand side of the module.
OBJECT-TYPE    
  INTEGER notExist(0), exist(1)  

trGroupLeftNeigbour 0.1.81.3.1.15
Attribute defining the existence of a neighbor another token ring group on the left hand side of the module.
OBJECT-TYPE    
  INTEGER notExist(0), exist(1)  

trGroupIoMode 0.1.81.3.1.16
Attribute defining the I/O mode (single, dual-ring-in, dual-ring-out) Lobe, Internal Repeater or Star) of a module from the the LTR-IO family.
OBJECT-TYPE    
  INTEGER single(0), dualRingIn(1), dualRingOut(2), lobe(4), intRepeater(5), star(6)  

trGroupRingSpeed 0.1.81.3.1.17
Attribute describing the bandwidth of the ring. In case of bridges it describes the speed of the first ring.
OBJECT-TYPE    
  INTEGER unknown(1), oneMegabit(2), fourMegabit(3), sixteenMegabit(4)  

trGroupTxLinkDown 0.1.81.3.1.18
Value ON of this attribute defines a TxLinkDown fault condition on a LANNET Token Ring repeater module.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupRxLinkDown 0.1.81.3.1.19
Value ON of this attribute defines an RxLinkDown fault condition on a LANNET Token Ring repeater module.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupManLinkLoop 0.1.81.3.1.20
Setting the value of this attribute to ON instructs the hardware of a LANNET Token Ring repeater module to close the loop in the direction of the external connection.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupManBusLoop 0.1.81.3.1.21
Setting the value of this attribute to ON instructs the hardware of a LANNET Token Ring repeater module to close the loop in the direction of the internal bus.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupAutoLinkLoop 0.1.81.3.1.22
Value ON of this attribute signifies that a hardware loop has been auto- matically closed by the hardwar of the LANNET Token Ring repeater as a result of problems on the external link.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupAutoBusLoop 0.1.81.3.1.23
Value ON of this attribute signifies that a hardware loop has been auto- matically closed by the hardware of the LANNET Token Ring repeater as a result of problems on the internal bus.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupIOModeF 0.1.81.3.1.24
Attribute defining the I/O mode (Ring-in, Ring-out) of a LANNET Token Ring repeater.
OBJECT-TYPE    
  INTEGER ringIn(1), ringOut(2), illegalMode(3)  

trGroupDescr 0.1.81.3.1.25
Descriptor of the group in ASCII (readable) format, mainly for use with generic management applications.
OBJECT-TYPE    
  STRING  

trGroupAgentIfType 0.1.81.3.1.26
This attribute describes the interfaces of agents eventually existing on LANNET modules and their type. Value none defines the lack of agent or of an interface recognized by the management console, while any other value defines an interface whose type is recognized by the the management console and may be used as a management channel.
OBJECT-TYPE    
  INTEGER none(1), regular1822(2), hdh1822(3), ddn-x25(4), rfc877-x25(5), ethernet-csmacd(6), iso88023-csmacd(7), iso88024-tokenBus(8), iso88025-tokenRing(9), iso88026-man(10), starLan(11), proteon-10MBit(12), proteon-80MBit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), t1-carrier(18), cept(19), basicIsdn(20), primaryIsdn(21), propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), ethernet-3Mbit(26), nsip(27), slip(28), ip(255)  

trGroupAgentAddress 0.1.81.3.1.27
This attribute defines an unique address by which the agent may be addres- sed by the management console. The address format should be consistent with the type defined by trGroupAgentIfType.
OBJECT-TYPE    
  STRING  

trGroupSecondRingSpeed 0.1.81.3.1.28
Attribute describing bandwidth of the ring. In case of bridges it describes the speed of the second ring.
OBJECT-TYPE    
  INTEGER unknown(1), oneMegabit(2), fourMegabit(3), sixteenMegabit(4)  

trGroupBridgeMode 0.1.81.3.1.29
Attribute describing the operational mode of the bridge. For ITLB the following modes are defined: - Mode A: First channel connected to an external ring (RI,RO connectors) and second channel connected to an internal ring; - Mode B: First channel connected to an external ring by a DTE connector and second channel connected to an internal ring; - Mode C: First channel connected to an internal left ring and second channel connected to an internal right ring.
OBJECT-TYPE    
  INTEGER modeA(1), modeB(2), modeC(3)  

trGroupFirstRingInserted 0.1.81.3.1.30
Attribute describing that the first ring in the case of a bridge requires or not insertion.
OBJECT-TYPE    
  INTEGER notInserted(1), inserted(2)  

trGroupSecondRingInserted 0.1.81.3.1.31
Attribute describing that the second ring in the case of a bridge requires or not insertion.
OBJECT-TYPE    
  INTEGER notInserted(1), inserted(2)  

trGroupStandAloneModeSwitch 0.1.81.3.1.32
Value On of this attribute defines Stand Alone Mode of a sensor. Internal ports are disabled and the card functions in a local star configuration to- ward its external ports.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupRedun12 0.1.81.3.1.33
Value ON of this attribute defines a redundancy (back-up) relation between synchronous external ports 1 and 2 on a LANNET module.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupRedun34 0.1.81.3.1.34
Value ON of this attribute defines a redundancy (back-up) relation between synchronous external ports 3 and 4 on a LANNET module.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupSuperRedundancy 0.1.81.3.1.35
Value ON of this attribute defines a redundancy (back-up) relation between all the internal ports on a LANNET module. By default port 1 is active, backed by port 2, backed by port 3 (if existing), etc.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trGroupInterProcCommStatus 0.1.81.3.1.36
This attribute describes the status of the communication between the microprocessor of the sensor and the microprocessor of the agent on cards with embedded agents.
OBJECT-TYPE    
  INTEGER ok(1), commProblems(2), noCommunication(3)  

trGroupCommunicationStatus 0.1.81.3.1.37
This attribute describes the communication status of the group with the SNMP Agent as detected and reported by the agent.
OBJECT-TYPE    
  INTEGER ok(1), commProblems(2)  

trGroupHardwareStatus 0.1.81.2.6.38
This attribute describes the status of the group hardware as detected by the sensors software.
OBJECT-TYPE    
  INTEGER ok(1), hardwareProblems(2)  

trPortTable 0.1.81.3.2
OBJECT-TYPE    
  SEQUENCE OF  
    TRPortEntry

trPortType 0.1.81.3.2.1
Attribute describing the type of Token Ring LANNET port.
OBJECT-TYPE    
  INTEGER lobeRJ45(9), lobeD9(10), lobeD25(11), lobeFO(12), ri104D25(13), ro104D25(14), riRJ45(15), riD9(16), riD25(17), riFO(18), ri104RJ45(19), ri104D9(20), roRJ45(21), roD9(22), roD25(23), roFO(24), ro104RJ45(25), ro104D9(26), ltrf4Port(31), ltrf16Port(32), itlbRoPort(36), itlbRiPort(37), itlbDTEPort(38), starFO(39)  

trPortID 0.1.81.3.2.2
Unique ID of the port in the trPortTable.
OBJECT-TYPE    
  INTEGER  

trPortBypass 0.1.81.3.2.3
Setting the value of this attribute to ON causes the by- passing of the TokenRing LANNET port.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trPortConnected 0.1.81.3.2.4
Attribute which describes the connection status of a Token Ring port (in- clusion of the Token Ring controller in the ring).
OBJECT-TYPE    
  INTEGER notConnected(0), connected(1)  

trPortTcp 0.1.81.3.2.5
Setting the value of this attribute to ON causes the activation of the cable-fault detection mechanism.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trPortCableFault 0.1.81.3.2.6
Value ON of this attribute signifies the detection of a cable-fault on this specific Token Ring port.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

trPortGroupID 0.1.81.3.2.7
ID of group to which the Token Ring port belongs.
OBJECT-TYPE    
  INTEGER  

trPortDescr 0.1.81.3.2.8
Descriptor of the group in ASCII (readable) format, mainly for use with generic management applications.
OBJECT-TYPE    
  STRING  

trPortFunctionalStatus 0.1.81.3.2.9
The value of this attribute reflects the functional status of LANNET Token Ring ports. Note that it is not mandatory that a certain port support all the enumerated states. Here is the lest of the possible states: OK - fully functional port, transmitting and receiving packets. RLD - receive link down condition on the port. TLD - transmit link down condition on the port.
OBJECT-TYPE    
  INTEGER ok(0), rld(1), tld(3)  

trPortActivityStatus 0.1.81.3.2.10
This attribute defines the status of ports who may be part of a redundan- cy schema. NotActive indicates a disabled port which cannot transmit or receive pac- kets even if included in a redundancy scheme. Dormant indicates an enabled port which does not transmit or receive pac- kets, but included in a redundancy schema is at any moment disponible for packets transmission and reception. Active indicates that the port transmits and receives packets, as the main path in the redundant configuration.
OBJECT-TYPE    
  INTEGER notActive(1), dormant(2), active(3)  

trIntPortTable 0.1.81.3.3
OBJECT-TYPE    
  SEQUENCE OF  
    TrIntPortEntry

trIntPortEntry 0.1.81.3.3.1
OBJECT-TYPE    
  TrIntPortEntry  

trIntPortGroupId 0.1.81.3.3.1.1
Id of the group to which the internal port belongs.
OBJECT-TYPE    
  INTEGER 0..255  

trIntPortId 0.1.81.3.3.1.2
Id of the internal port in the trInPortTable.
OBJECT-TYPE    
  INTEGER 0..255  

trIntPortBusConnection 0.1.81.3.3.1.3
The value of this attribute defines the bus to which the internal port is connected. Internal Ethernet buses are numbered 1,2 in LET18 enclosures and 1 to 4 in LET36 enclosures.
OBJECT-TYPE    
  INTEGER 0..255  

trIntPortAdminStatus 0.1.81.3.3.1.4
A disabled port neither transmits or receives. The port must be explicitely enabled to restore operation.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

trRingTable 0.1.81.3.4
OBJECT-TYPE    
  SEQUENCE OF  
    TrRingEntry

trRingEntry 0.1.81.3.4.1
OBJECT-TYPE    
  TrRingEntry  

trRingIndex 0.1.81.3.4.1.1
Id of the ring in the trRingTable.
OBJECT-TYPE    
  INTEGER 0..255  

trRingCurTraffic 0.1.81.3.4.1.2
Record of traffic for the last second with a resolution of 100 msec. The traffic is expressed in percents of the maximum effective TR traffic (token messages are excluded) and each record contains 10 readings, in range 1..20 on log(10) scale.
OBJECT-TYPE    
  STRING  

trRingTrafficTrsh 0.1.81.3.4.1.3
Traffic threshold value. When exceeded, a trap is send to the management console. Expressed in percents of the maximum effective TR traffic (token messages are excluded) in the range 1..20 on log(10) scale.
OBJECT-TYPE    
  INTEGER  

trRingPeakTraffic 0.1.81.3.4.1.4
Maximal traffic value since last reset of agent. Expressed in percents of the maximum effective TR traffic (token messages are excluded), in the range 1..20 on log(10) scale.
OBJECT-TYPE    
  INTEGER  

srlSpecific 0.1.81.4
OBJECT IDENTIFIER    

srlportTable 0.1.81.4.2
OBJECT-TYPE    
  SEQUENCE OF  
    SRLPortEntry

srlportEntry 0.1.81.4.2.1
OBJECT-TYPE    
  SRLPortEntry  

srlportGroupID 0.1.81.4.2.1.1
ID of group to which the Terminal Server port belongs.
OBJECT-TYPE    
  INTEGER  

srlportID 0.1.81.4.2.1.2
Unique Id of the port in the srlportEntry.
OBJECT-TYPE    
  INTEGER  

srlportType 0.1.81.4.2.1.3
Attribute describing the type of the LANNET Terminal Server port.
OBJECT-TYPE    
  INTEGER lts16Port(33)  

srlportAdminStatus 0.1.81.4.2.1.4
A disabled port neither transmits or receives. The port must be explicitely enabled to restore operation.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

srlportDescr 0.1.81.4.2.1.5
Descriptor of the group in ASCII (readable) format, mainly for use with generic management applications.
OBJECT-TYPE    
  STRING  

ltSpecific 0.1.81.5
OBJECT IDENTIFIER    

ltGroupTable 0.1.81.5.1
OBJECT-TYPE    
  SEQUENCE OF  
    LTGroupEntry

ltGroupEntry 0.1.81.5.1.1
OBJECT-TYPE    
  LTGroupEntry  

ltGroupID 0.1.81.5.1.1.1
Unique ID of the group in ltGroupTable. Equivalent to slot number in LANNET enclosures.
OBJECT-TYPE    
  INTEGER  

ltGroupNumberOfPorts 0.1.81.5.1.1.2
Number of ports in group. Range 1..255. It is assumed that on each group the ports are numbered uniquely in the range from 1 to standardGroupNumberOf Ports. They corespond to the number of ports of the module (FRU)
OBJECT-TYPE    
  INTEGER  

ltGroupAutoMan 0.1.81.5.1.1.3
This attribute reflects the status of the auto/manual switch which defi- nes the working mode of LANNET sensors. On Manual mode no set operations may be performed on attributes related to sensor. The sensor works acor- ding to configuration switches set by hardware methods and transmits all configuration information to the agent. On Auto mode hardware switches are overridden by set commands.
OBJECT-TYPE    
  INTEGER man(0), auto(1)  

ltGroupReset 0.1.81.5.1.1.4
Setting the value of this attribute to ON is interpreted as a software RESET command. Sensor software is reinitialised and acording to the sensor specifications, partial or total reset of the module hardware may be performed.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

ltGroupHWVersion 0.1.81.5.1.1.5
ASCII string for description and display of the sensor hardware version, as it is known by the agent software.
OBJECT-TYPE    
  STRING  

ltGroupSWVersion 0.1.81.5.1.1.6
ASCII string for description and display of the sensor application soft- ware.
OBJECT-TYPE    
  STRING  

ltGroupKernelVersion 0.1.81.5.1.1.7
ASCII string for description and display of the sensor kernel software.
OBJECT-TYPE    
  STRING  

ltGroupType 0.1.81.5.1.1.8
Attribute describing the type of LANNET Terminal Server group.
OBJECT-TYPE    
  INTEGER llt8(36)  

ltGroupFullConfig 0.1.81.5.1.1.9
Attribute describing the full configuration of a terminal server group in internal LANNET application format.
OBJECT-TYPE    
  STRING  

ltGroupDescr 0.1.81.5.1.1.10
Descriptor of the group in ASCII (readable) format, mainly for use with generic management applications.
OBJECT-TYPE    
  STRING  

ltGroupInterProcCommStatus 0.1.81.5.1.1.11
This attribute describes the status of the communication between the microprocessor of the sensor and the microprocessor of the agent on cards with embedded agents.
OBJECT-TYPE    
  INTEGER ok(1), commProblems(2), noCommunication(3)  

ltGroupStandAloneModeSwitch 0.1.81.5.1.1.12
Value On of this attribute defines Stand Alone Mode of a sensor. Internal ports are disabled and the card functions in a local star configuration to- ward its external ports.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

ltGroupCommunicationStatus 0.1.81.5.1.1.13
This attribute describes the communication status of the group with the SNMP Agent as detected and reported by the agent.
OBJECT-TYPE    
  INTEGER ok(1), commProblems(2)  

ltPortTable 0.1.81.5.2
OBJECT-TYPE    
  SEQUENCE OF  
    LTPortEntry

ltPortEntry 0.1.81.5.2.1
OBJECT-TYPE    
  LTPortEntry  

ltPortGroupID 0.1.81.5.2.1.1
ID of group to which the Local Talk card belongs.
OBJECT-TYPE    
  INTEGER  

ltPortID 0.1.81.5.2.1.2
Unique Id of the port in the ltPortEntry.
OBJECT-TYPE    
  INTEGER  

ltPortType 0.1.81.5.2.1.3
Attribute describing the type of the LANNET Local Talk card port.
OBJECT-TYPE    
  INTEGER llt8Port(34)  

ltPortAdminStatus 0.1.81.5.2.1.4
A disabled port neither transmits or receives. The port must be explicitely enabled to restore operation.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

ltPortTest 0.1.81.5.2.1.5
A value ON of this attribute indicates that a port test should be performed upon the port defined be the attribute instance.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

ltPortTestResult 0.1.81.5.2.1.6
Indicates the result of a port test performed on this port.
OBJECT-TYPE    
  INTEGER ok(1), faulty(2)  

ltPortJam 0.1.81.5.2.1.7
An ON value of this attribute indicates a Jam error on the specific port.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

ltPortDescr 0.1.81.5.2.1.8
Descriptor of the group in ASCII (readable) format, mainly for use with generic management applications.
OBJECT-TYPE    
  STRING  

ltIntPortTable 0.1.81.5.3
OBJECT-TYPE    
  SEQUENCE OF  
    LTIntPortEntry

ltIntPortEntry 0.1.81.5.3.1
OBJECT-TYPE    
  LTIntPortEntry  

ltIntPortGroupId 0.1.81.5.3.1.1
Id of the group to which the internal port belongs.
OBJECT-TYPE    
  INTEGER 0..255  

ltIntPortId 0.1.81.5.3.1.2
Id of the internal port in the ltIntPortTable.
OBJECT-TYPE    
  INTEGER 0..255  

ltIntPortAdminStatus 0.1.81.5.3.1.3
A disabled internal port neither transmits or receives. The port must be explicitely enabled to restore operation.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

ltIntPortBusConnection 0.1.81.5.3.1.4
The value of this attribute defines the bus to which the internal port is connected. Local Talk cards inserted in LET18 type enclosures may access 2 buses, while Local Talk cards inserted in LET18 type enclosures may access 4 buses.
OBJECT-TYPE    
  INTEGER 0..255