Juniper-UNI-SONET-MIB

File: Juniper-UNI-SONET-MIB.mib (43362 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB Juniper-TC Juniper-MIBs

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Unsigned32
Integer32 NOTIFICATION-TYPE DisplayString
TruthValue TEXTUAL-CONVENTION RowStatus
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
ifIndex InterfaceIndex InterfaceIndexOrZero
ifAlias JuniNextIfIndex juniMibs

Defined Types

JuniSonetLineSpeed  
The set of SONET Line Speeds.
TEXTUAL-CONVENTION    
  INTEGER sonetUnknownSpeed(0), sonetOc1Stm0(1), sonetOc3Stm1(2), sonetOc12Stm3(3), sonetOc48Stm16(4)  

JuniSonetLogicalPathChannel  
A SONET Path channel description that uniquely identifies the SONET Path and is administratively assigned.
TEXTUAL-CONVENTION    
  Integer32 0..2147483647  

JuniSonetPathHierarchy  
Represents textual information taken from the NVT ASCII character set. The SONET path hierarchy is based upon the SONET line capacity. Configuration examples follow the diagram below, which depicts the SONET Path hierarchy. OC-192/STM-64 ^ | OC-48/STM-16 (1-4) ^ | OC-12/STM-4 (1-4) ^ | OC-3/STM-1 (1-4) ^ | OC-1/STM-0 (1-3) ^ | ^----------------^----------------^ | | | DS3 (1) VT1.5/TU11 DS1 (1-28) VT2/TU12 (1-21) For Line Speed = OC-48/STM-16: When the entire capacity contains only one path, no specifier is used. OC-12/STM-4 Path To specify an OC-12 path over OC-48 provide a single digit of the form a where: a - OC-12/STM-4 path number (1-4) OC-3/STM-1 Path To specify an OC-3 Path over OC-48 provide two digits of the form a/b where: a - OC-12/STM-4 path number (1-4) b - OC-3/STM-1 path within the OC-12 (1-4) OC-1/STM-0 Path To specify an OC1 Path over OC-48 provide three digits of the form a/b/c where: a - OC-12/STM-4 path number (1-4) b - OC-3/STM-1 path number within OC-12 (1-4) c - OC-1/STM-0 path number within OC-3 (1-3) For Line Speed = OC-12/STM-4: OC-12/STM-4 Path: When entire line capacity contains only one path, no channel-specifier is used. OC-3/STM-1 Path: To specify an OC-3 path over OC-12 provide a single digit of the form a where: a - OC-3/STM-1 path within the OC-12 (1-4) OC-1 Path: To specify an OC-1 path over OC-12 provide two digits of the form a/b where: a - OC-3/STM-1 path within the OC-12 (1-4) b - OC-1/STM-0 path within the OC-3 (1-3) For Line Speed = OC-3/STM-1: OC-3/STM-1 Path: When entire line capacity contains only one path, no channel-specifier is used. OC-1 Path: To specify an OC-1 path over OC-3 provide one digit of the form a where: a - OC-1/STM-1 path within the OC-3 (1-3)
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..32)  

JuniSonetPathC2ByteOverride  
SONET Path c2 overhead byte. This value should only be set in cases where the value set by the upper interface type needs to be overridden. Standard values are: 0 Unequipped 1 Nonspecific 2 Floating VT 4 Asyncronous mapping of DS3 19 ATM 22 HDLC over Sonet - scrambling enabled 207 HDLC over Sonet - no scrambling
TEXTUAL-CONVENTION    
  Integer32 0..255  

JuniSonetVTType  
The SONET Virtual Tributary Type. This TC has been deprecated because RFC2558 provides this information in SONET-MIB.sonetVTCurrentWidth.
TEXTUAL-CONVENTION    
  INTEGER tribVT15TU11(0), tribVT20TU12(1), tribVT3(3), tribVT6(4), tribVT6c(5)  

JuniSonetMediumEntry  
SEQUENCE    
  juniSonetMediumType INTEGER
  juniSonetMediumLoopbackConfig INTEGER
  juniSonetMediumTimingSource INTEGER
  juniSonetMediumCircuitIdentifier DisplayString
  juniSonetMediumTriggerAlarms BITS
  juniSonetMediumTriggerDelay Integer32

JuniSonetPathCapabilityEntry  
SEQUENCE    
  juniSonetPathRemoveFlag TruthValue
  juniSonetPathChannelized TruthValue
  juniSonetPathMaximumChannels Unsigned32
  juniSonetPathMinimumPathSpeed JuniSonetLineSpeed
  juniSonetPathMaximumPathSpeed JuniSonetLineSpeed

JuniSonetPathEntry  
SEQUENCE    
  juniSonetPathIfIndex InterfaceIndex
  juniSonetPathLogicalChannel JuniSonetLogicalPathChannel
  juniSonetPathSpeed JuniSonetLineSpeed
  juniSonetPathHierarchy JuniSonetPathHierarchy
  juniSonetPathLowerIfIndex InterfaceIndexOrZero
  juniSonetPathRowStatus RowStatus
  juniSonetPathTriggerAlarms BITS
  juniSonetPathC2ByteOverrideFlag TruthValue
  juniSonetPathC2ByteOverride JuniSonetPathC2ByteOverride
  juniSonetPathTriggerDelay Integer32
  juniSonetPathEventStatus Unsigned32

JuniSonetVTEntry  
SEQUENCE    
  juniSonetVTIfIndex InterfaceIndex
  juniSonetVTPathLogicalChannel JuniSonetLogicalPathChannel
  juniSonetVTType JuniSonetVTType
  juniSonetVTPathPayload Unsigned32
  juniSonetVTTributaryGroup Unsigned32
  juniSonetVTTributarySubChannel Unsigned32
  juniSonetVTLowerIfIndex InterfaceIndexOrZero
  juniSonetVTRowStatus RowStatus

Defined Values

juniSonetMIB 1.3.6.1.4.1.4874.2.2.7
The SONET MIB for the Juniper Networks enterprise. This MIB contains managed objects for SONET interfaces. It contains management objects for configuration of interface attributes that either are absent from, or read-only in the standard SONET-MIB.
MODULE-IDENTITY    

juniSonetObjects 1.3.6.1.4.1.4874.2.2.7.1
OBJECT IDENTIFIER    

juniSonetPathObjects 1.3.6.1.4.1.4874.2.2.7.2
OBJECT IDENTIFIER    

juniSonetVTObjects 1.3.6.1.4.1.4874.2.2.7.3
OBJECT IDENTIFIER    

juniSonetMediumTable 1.3.6.1.4.1.4874.2.2.7.1.1
This table contains entries for SONET interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniSonetMediumEntry

juniSonetMediumEntry 1.3.6.1.4.1.4874.2.2.7.1.1.1
Each entry describes the characteristics of an SONET interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniSonetMediumEntry  

juniSonetMediumType 1.3.6.1.4.1.4874.2.2.7.1.1.1.1
This variable identifies whether a SONET or a SDH signal is used across this interface. This object was deprecated because the same information is provided by the SONET-MIB.sonetMediumType object (RFC 2558).
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER sonet(1), sdh(2)  

juniSonetMediumLoopbackConfig 1.3.6.1.4.1.4874.2.2.7.1.1.1.2
The current loopback state of the SONET/SDH interface. The values mean: sonetNoLoop Not in the loopback state. A device that is not capable of performing a loopback on this interface shall always return this value. sonetFacilityLoop The received signal at this interface is looped back out through the corresponding transmitter in the return direction. sonetTerminalLoop The signal that is about to be transmitted is connected to the associated incoming receiver. sonetOtherLoop Loopbacks that are not defined here.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sonetNoLoop(0), sonetFacilityLoop(1), sonetTerminalLoop(2), sonetOtherLoop(3)  

juniSonetMediumTimingSource 1.3.6.1.4.1.4874.2.2.7.1.1.1.3
Selects the source from which transmit timing is derived. loop timing is recovered from the receiver internalModule timing is from the module associated with this interface internalChassis timing is taken from the internal system timing reference
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loop(0), internalModule(1), internalChassis(2)  

juniSonetMediumCircuitIdentifier 1.3.6.1.4.1.4874.2.2.7.1.1.1.4
This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting. This object was deprecated because the same information is provided by the SONET-MIB.sonetMediumCircuitIdentifier object (RFC 2558).
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString  

juniSonetMediumTriggerAlarms 0.0.2.3.1.3.6.1.4.1.4874.2.2.7.1.1.1.5
The alarms that are used in the operational status calculation for this SONET interface. sectionLOS When this bit is set, section LOS is used for operational status calculation. sectionLOF When this bit is set, section LOF is used for operational status calculation. lineAIS When this bit is set, line AIS is used for operational status calculation. lineRDI When this bit is set, line RDI is used for operational status calculation. The value of this object defaults to all the bits set, indicating all of the alarms are used for the operational status calculation.
Status: current Access: read-only
OBJECT-TYPE    
  BITS sectionLOS(0), sectionLOF(1), lineAIS(2), lineRDI(3)  

juniSonetMediumTriggerDelay 1.3.6.1.4.1.4874.2.2.7.1.1.1.6
The time delay (in milliseconds) before a defect is accepted as an alarm for this SONET interface.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2500  

juniSonetPathCapabilityTable 1.3.6.1.4.1.4874.2.2.7.2.1
This table contains entries for SONET Paths present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniSonetPathCapabilityEntry

juniSonetPathCapabilityEntry 1.3.6.1.4.1.4874.2.2.7.2.1.1
Each entry describes the SONET path capability of a SONET interface. This table is index by the ifIndex of the SONET interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniSonetPathCapabilityEntry  

juniSonetPathRemoveFlag 1.3.6.1.4.1.4874.2.2.7.2.1.1.1
This variable identifies whether a SONET/SDH supports the deletion of SONET Paths. A value of true(1) indicates the SONET path is removable; a value of false(2) indicates the SONET path cannot be removed.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

juniSonetPathChannelized 1.3.6.1.4.1.4874.2.2.7.2.1.1.2
Identifies whether or not this SONET interface supports channelization. A value of true(1) indicates the SONET path is channelized; a value of false(2) indicates the SONET path is not channelized.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

juniSonetPathMaximumChannels 1.3.6.1.4.1.4874.2.2.7.2.1.1.3
Identifies the maximum number of SONET paths/channels for this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniSonetPathMinimumPathSpeed 1.3.6.1.4.1.4874.2.2.7.2.1.1.4
Identifies the minimum SONET path speed for this interface.
Status: current Access: read-only
OBJECT-TYPE    
  JuniSonetLineSpeed  

juniSonetPathMaximumPathSpeed 1.3.6.1.4.1.4874.2.2.7.2.1.1.5
Identifies the maximum SONET path speed for this interface.
Status: current Access: read-only
OBJECT-TYPE    
  JuniSonetLineSpeed  

juniSonetPathNextIfIndex 1.3.6.1.4.1.4874.2.2.7.2.2
Coordinate ifIndex value allocation for entries in juniSonetPathTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
Status: current Access: read-only
OBJECT-TYPE    
  JuniNextIfIndex  

juniSonetPathTable 1.3.6.1.4.1.4874.2.2.7.2.3
This table contains entries for SONET Path interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniSonetPathEntry

juniSonetPathEntry 1.3.6.1.4.1.4874.2.2.7.2.3.1
Each entry describes the characteristics of an SONET Path interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniSonetPathEntry  

juniSonetPathIfIndex 1.3.6.1.4.1.4874.2.2.7.2.3.1.1
The ifIndex of the SONET Path interface. When creating entries in this table, suitable values for this object are determined by reading juniSonetPathNextIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniSonetPathLogicalChannel 1.3.6.1.4.1.4874.2.2.7.2.3.1.2
The logical channel number assigned to this SONET Path. If the underlying SONET interface does not support channelization, the value of this object is zero.
Status: current Access: read-create
OBJECT-TYPE    
  JuniSonetLogicalPathChannel  

juniSonetPathSpeed 1.3.6.1.4.1.4874.2.2.7.2.3.1.3
The line speed associated with this SONET PATH.
Status: current Access: read-create
OBJECT-TYPE    
  JuniSonetLineSpeed  

juniSonetPathHierarchy 1.3.6.1.4.1.4874.2.2.7.2.3.1.4
The SONET Path hierarchy associated with this path.
Status: current Access: read-create
OBJECT-TYPE    
  JuniSonetPathHierarchy  

juniSonetPathLowerIfIndex 1.3.6.1.4.1.4874.2.2.7.2.3.1.5
The ifIndex of the interface over which this SONET Path interface is to be layered - typically a SONET/SDH interface. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniSonetPathRowStatus 1.3.6.1.4.1.4874.2.2.7.2.3.1.6
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniSonetPathRowStatus juniSonetPathSpeed juniSonetPathHierarchy juniSonetPathLowerIfIndex The logical channel may optionally be specified. If it is not specified an unused logical channel value will be assigned by the system. juniSonetPathLogicalChannel In addition, when creating an entry the following conditions must hold: A value for juniSonetPathIfIndex must have been determined previously, by reading juniSonetPathNextIfIndex. The interface identified by the juniSonetPathLowerIfIndex must exist. The juniSonetPathSpeed must be consistent with the speed for the channel specified by the juniSonetPathHierarchy, based on the speed of the interface identified by the juniSonetPathLowerIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniSonetPathTriggerAlarms 0.1.1.3.6.1.4.1.4874.2.2.7.2.3.1.7
The path alarms that are used in the operational status calculation for this SONET Path. pathLOP When this bit is set, path LOP is used for operational status calculation. This bit may not be modified. pathAIS When this bit is set, path AIS is used for operational status calculation. This bit may not be modified. pathRDI When this bit is set, path RDI is used for operational status calculation. The value of this object defaults to bits 0 and 1 set, indication LOP and AIS will be used for operational status calculation this SONET Path.
Status: current Access: read-create
OBJECT-TYPE    
  BITS pathLOP(0), pathAIS(1), pathRDI(2)  

juniSonetPathC2ByteOverrideFlag 1.3.6.1.4.1.4874.2.2.7.2.3.1.8
The path overhead c2 transmit override enable. If set to true(1), juniSonetPathC2Byte override value must be specified. If set to false(2), c2 byte will be automatically set by the system based on the upper interface type.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniSonetPathC2ByteOverride 1.3.6.1.4.1.4874.2.2.7.2.3.1.9
The path overhead c2 transmit and expected value for this SONET Path.
Status: current Access: read-create
OBJECT-TYPE    
  JuniSonetPathC2ByteOverride  

juniSonetPathTriggerDelay 1.3.6.1.4.1.4874.2.2.7.2.3.1.10
The time delay (in milliseconds) before a defect is accepted as an alarm for this SONET Path.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2500  

juniSonetPathEventStatus 1.3.6.1.4.1.4874.2.2.7.2.3.1.11
This variable specifies which events have occurred in the current 15 minute interval. The value represents a vector of bits, each specifying a unique event: - Bit 0 Rising threshold alarm, sonetPathCurrentESs. - Bit 1 Rising threshold alarm, sonetPathCurrentSESs. - Bit 2 Reserved. - Bit 3 Rising threshold alarm, sonetPathCurrentCVs. - Bit 4 Rising threshold alarm, sonetPathCurrentUASs. - Bit 5 LOP failure indication. - Bit 6 LOP failure cleared. - Bit 7 AIS failure indication. - Bit 8 AIS failure cleared. - Bit 9 RFI indication. - Bit 10 RFI cleared. - Bit 11 UNEQ failure indication. - Bit 12 UNEQ failure cleared. - Bit 13 PLM failure indication. - Bit 14 PLM failure cleared.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..32767  

juniSonetVTNextIfIndex 1.3.6.1.4.1.4874.2.2.7.3.1
Coordinate ifIndex value allocation for entries in juniSonetVTTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
Status: current Access: read-only
OBJECT-TYPE    
  JuniNextIfIndex  

juniSonetVTTable 1.3.6.1.4.1.4874.2.2.7.3.2
This table contains entries for SONET Virtual Tributary interfaces present in the system. This table augments the standard SONET-MIB.sonetVTCurrentTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniSonetVTEntry

juniSonetVTEntry 1.3.6.1.4.1.4874.2.2.7.3.2.1
Each entry describes the characteristics of an SONET Virtual Tributary interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniSonetVTEntry  

juniSonetVTIfIndex 1.3.6.1.4.1.4874.2.2.7.3.2.1.1
The ifIndex of the SONET Virtual Tributary interface. When creating entries in this table, suitable values for this object are determined by reading juniSonetVTNextIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniSonetVTPathLogicalChannel 1.3.6.1.4.1.4874.2.2.7.3.2.1.2
The SONET Path logical channel number associated with this virtual tributary.
Status: current Access: read-create
OBJECT-TYPE    
  JuniSonetLogicalPathChannel  

juniSonetVTType 1.3.6.1.4.1.4874.2.2.7.3.2.1.3
The SONET virtual tributary type. This object was deprecated because the same information is provided in the SONET-MIB.sonetVTCurrentWidth object.
Status: deprecated Access: read-create
OBJECT-TYPE    
  JuniSonetVTType  

juniSonetVTPathPayload 1.3.6.1.4.1.4874.2.2.7.3.2.1.4
The SONET Path payload number associated with this virtual tributary. For SDH mode, this is a value with a range from 1-3. For SONET mode, the value of this object is always 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniSonetVTTributaryGroup 1.3.6.1.4.1.4874.2.2.7.3.2.1.5
The SONET Path group number for this virtual tributary. In SONET and SDH mode, the value of this object is 1-7.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniSonetVTTributarySubChannel 1.3.6.1.4.1.4874.2.2.7.3.2.1.6
Specifies the virtual tributary number within the tributary group defined by juniSonetVTTributaryGroup object. The value of this object ranges from 1-4 if the tributary type is tribVT15/TU11(0); and the values 1-3 if the tributary type is tribVT20/TU12(1).
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniSonetVTLowerIfIndex 1.3.6.1.4.1.4874.2.2.7.3.2.1.7
The ifIndex of the interface over which this SONET Virtual Tributary interface is to be layered - typically a SONET PATH interface. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniSonetVTRowStatus 1.3.6.1.4.1.4874.2.2.7.3.2.1.8
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniSonetVTRowStatus juniSonetVTPathLogicalChannel juniSonetVTType juniSonetVTPathPayload juniSonetVTTributaryGroup juniSonetVTTributarySubChannel juniSonetVTLowerIfIndex In addition, when creating an entry the following conditions must hold: A value for juniSonetVTIfIndex must have been determined previously, by reading juniSonetVTNextIfIndex. The interface identified by juniSonetVTLowerIfIndex must exist. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniSonetTrapControl 1.3.6.1.4.1.4874.2.2.7.5
OBJECT IDENTIFIER    

juniSonetPathEventIfIndex 1.3.6.1.4.1.4874.2.2.7.5.1
The ifIndex of the SONET Path interface. This is the same value as juniSonetPathIfIndex for the interface that is reporting an event.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  InterfaceIndex  

juniSonetTraps 1.3.6.1.4.1.4874.2.2.7.6
OBJECT IDENTIFIER    

juniSonetTrapPrefix 1.3.6.1.4.1.4874.2.2.7.6.0
OBJECT IDENTIFIER    

juniSonetPathEvents 1.3.6.1.4.1.4874.2.2.7.6.0.1
This trap reports SONET path events for the failures and normal conditions of the SONET path entity.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

juniSonetConformance 1.3.6.1.4.1.4874.2.2.7.4
OBJECT IDENTIFIER    

juniSonetCompliances 1.3.6.1.4.1.4874.2.2.7.4.1
OBJECT IDENTIFIER    

juniSonetGroups 1.3.6.1.4.1.4874.2.2.7.4.2
OBJECT IDENTIFIER    

juniSonetCompliance 1.3.6.1.4.1.4874.2.2.7.4.1.1
Obsolete compliance statement for entities which implement the Juniper SONET MIB. This statement became obsolete when the SONET Path and SONET VT groups of objects were added.
Status: obsolete Access: accessible-for-notify
MODULE-COMPLIANCE    

juniSonetCompliance2 1.3.6.1.4.1.4874.2.2.7.4.1.2
Obsolete compliance statement for entities which implement the Juniper SONET MIB. This statement became obsolete when the juniSonetMediumType, juniSonetMediumCircuitIdentifier and juniSonetVTType objects were deprecated.
Status: obsolete Access: accessible-for-notify
MODULE-COMPLIANCE    

juniSonetCompliance3 1.3.6.1.4.1.4874.2.2.7.4.1.3
Obsolete compliance statement for entities which implement the Juniper SONET MIB. This statement became obsolete when support was added for alarm triggers and path c2 byte override.
Status: obsolete Access: accessible-for-notify
MODULE-COMPLIANCE    

juniSonetCompliance4 1.3.6.1.4.1.4874.2.2.7.4.1.4
Obsolete compliance statement for entities which implement the Juniper SONET MIB. This statement became obsolete when the SONET Path event status and notification support was added.
Status: obsolete Access: accessible-for-notify
MODULE-COMPLIANCE    

juniSonetCompliance5 1.3.6.1.4.1.4874.2.2.7.4.1.5
The compliance statement for entities which implement the Juniper SONET MIB.
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE    

juniSonetGroup 1.3.6.1.4.1.4874.2.2.7.4.2.1
Obsolete collection of objects providing management of SONET/SDH interfaces in a Juniper product. This group became obsolete when the juniSonetMediumType and juniSonetMediumCircuitIdentifier objects were deprecated.
Status: obsolete Access: accessible-for-notify
OBJECT-GROUP    

juniSonetPathGroup 1.3.6.1.4.1.4874.2.2.7.4.2.2
Obsolete collection of objects providing management of SONET/SDH Path interfaces in a Juniper product. This group became obsolete when new SONET path objects were added.
Status: obsolete Access: accessible-for-notify
OBJECT-GROUP    

juniSonetVirtualTributaryGroup 1.3.6.1.4.1.4874.2.2.7.4.2.3
Obsolete collection of objects providing management of SONET virtual tributaries in a Juniper product. This group became obsolete when juniSonetVTType was deprecated.
Status: obsolete Access: accessible-for-notify
OBJECT-GROUP    

juniSonetGroup2 1.3.6.1.4.1.4874.2.2.7.4.2.4
Obsolete collection of objects providing management of SONET/SDH interfaces in a Juniper product. This group became obsolete when juniSonetMediumTriggerAlarms was added.
Status: obsolete Access: accessible-for-notify
OBJECT-GROUP    

juniSonetVirtualTributaryGroup2 1.3.6.1.4.1.4874.2.2.7.4.2.5
A collection of objects providing management of SONET virtual tributaries in a Juniper product.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

juniSonetDeprecatedMediumGroup 1.3.6.1.4.1.4874.2.2.7.4.2.6
A collection of deprecated objects providing management of SONET/SDH interfaces in a Juniper product. This group is deprecated because the same information is provided by SONET-MIB objects (RFC 2558). Support for the objects in this group will be phased out over time.
Status: deprecated Access: accessible-for-notify
OBJECT-GROUP    

juniSonetDeprecatedVTGroup 1.3.6.1.4.1.4874.2.2.7.4.2.7
A deprecated object providing management of SONET/SDH VT interfaces in a Juniper product. This group is deprecated because the same information is provided by SONET-MIB objects (RFC 2558). Support for the VT type object will be phased out over time.
Status: deprecated Access: accessible-for-notify
OBJECT-GROUP    

juniSonetGroup3 1.3.6.1.4.1.4874.2.2.7.4.2.8
A collection of objects providing management of SONET/SDH interfaces in a Juniper product.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

juniSonetPathGroup2 1.3.6.1.4.1.4874.2.2.7.4.2.9
Obsolete collection of management objects providing management of SONET/SDH Path interfaces in a Juniper product. This group became obsolete when path event notification support was added.
Status: obsolete Access: accessible-for-notify
OBJECT-GROUP    

juniSonetPathGroup3 1.3.6.1.4.1.4874.2.2.7.4.2.10
A collection of objects providing management of SONET/SDH Path interfaces in a Juniper product.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

juniSonetPathNotificationGroup 1.3.6.1.4.1.4874.2.2.7.4.2.11
A management notification for signaling SONET Path interface status changes in a Juniper product.
Status: current Access: accessible-for-notify