Juniper-ATM-1483-Profile-MIB

File: Juniper-ATM-1483-Profile-MIB.mib (33988 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
Juniper-MIBs Juniper-TC Juniper-PROFILE-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Unsigned32
Gauge32 Integer32 MODULE-COMPLIANCE
OBJECT-GROUP DisplayString juniMibs
JuniEnable JuniSetMap JuniProfileIfEncaps

Defined Types

JuniAtm1483ProfileEntry  
SEQUENCE    
  juniAtm1483ProfileId Unsigned32
  juniAtm1483ProfileSetMap JuniSetMap
  juniAtm1483ProfileVccType INTEGER
  juniAtm1483ProfileVccServiceCategory INTEGER
  juniAtm1483ProfileVccPcr Gauge32
  juniAtm1483ProfileVccScr Gauge32
  juniAtm1483ProfileVccMbs Gauge32
  juniAtm1483ProfileIfAlias DisplayString
  juniAtm1483ProfileAdvisoryRxSpeed Integer32
  juniAtm1483ProfileVccOamAdminStatus INTEGER
  juniAtm1483ProfileVccOamLoopbackFrequency Unsigned32
  juniAtm1483ProfileVcClassName DisplayString

JuniAtm1483ProfileAutoConfEntry  
SEQUENCE    
  juniAtm1483ProfileAutoConfId Unsigned32
  juniAtm1483ProfileAutoConfEncaps JuniProfileIfEncaps
  juniAtm1483ProfileAutoConfEnable JuniEnable
  juniAtm1483ProfileAutoConfLockoutMin Integer32
  juniAtm1483ProfileAutoConfLockoutMax Integer32

JuniAtm1483ProfileNestedProfileEntry  
SEQUENCE    
  juniAtm1483ProfileNestedProfileId Unsigned32
  juniAtm1483ProfileNestedProfileEncaps JuniProfileIfEncaps
  juniAtm1483ProfileNestedProfileUpperIfProfileName DisplayString

JuniAtm1483ProfileSubscriberEntry  
SEQUENCE    
  juniAtm1483ProfileSubscriberId Unsigned32
  juniAtm1483ProfileSubscriberEncaps JuniProfileIfEncaps
  juniAtm1483ProfileSubscriberNamePrefix JuniEnable
  juniAtm1483ProfileSubscriberName DisplayString
  juniAtm1483ProfileSubscriberPasswordPrefix JuniEnable
  juniAtm1483ProfileSubscriberPassword DisplayString
  juniAtm1483ProfileSubscriberDomain DisplayString

Defined Values

juniAtm1483ProfileMIB 1.3.6.1.4.1.4874.2.2.58
The ATM Profile MIB for the Juniper Networks, Inc. enterprise.
MODULE-IDENTITY    

juniAtm1483ProfileObjects 1.3.6.1.4.1.4874.2.2.58.1
OBJECT IDENTIFIER    

juniAtm1483Profile 1.3.6.1.4.1.4874.2.2.58.1.1
OBJECT IDENTIFIER    

juniAtm1483ProfileTable 1.3.6.1.4.1.4874.2.2.58.1.1.1
This table contains profiles for configuring bulk ATM circuits. Entries in this table are created/deleted as a side-effect of corresponding operations to the juniProfileNameTable in the Juniper-PROFILE-MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtm1483ProfileEntry

juniAtm1483ProfileEntry 1.3.6.1.4.1.4874.2.2.58.1.1.1.1
A profile describing VCC configuration of an ATM subinterface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtm1483ProfileEntry  

juniAtm1483ProfileId 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.1
The integer identifier associated with this profile. A value for this identifier is determined by locating or creating a profile name in the juniProfileNameTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtm1483ProfileSetMap 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.2
A bitmap representing which objects in this entry have been explicitly configured. See the definition of the JuniSetMap TEXTUAL-CONVENTION for details of use. The INDEX object(s) and this object are excluded from representation (i.e. their bits are never set). When a SET request does not explicitly configure JuniSetMap, bits in JuniSetMap are set as a side-effect of configuring other profile attributes in the same entry. If, however, a SET request explicitly configures JuniSetMap, the explicitly configured value overrides 1) any previous bit settings, and 2) any simultaneous 'side-effect' settings that would otherwise occur. Once set, bits can only be cleared by explicitly configuring JuniSetMap.
Status: current Access: read-write
OBJECT-TYPE    
  JuniSetMap  

juniAtm1483ProfileVccType 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.3
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. 'autoconfig' will recognize both VcMux and LLC formats.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER rfc1483VcMux(0), rfc1483Llc(1), autoconfig(2)  

juniAtm1483ProfileVccServiceCategory 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.4
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-realtime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)  

juniAtm1483ProfileVccPcr 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.5
Peak Cell Rate, in kilo-bits per second (kbps), of this circuit. This parameter is only required when juniAtm1483ProfileVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr cbr rtVbr
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

juniAtm1483ProfileVccScr 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.6
Sustained Cell Rate, in kilo-bits per second (kbps), of this circuit. This parameter is only required when juniAtm1483ProfileVccServiceCategory is configured to have one of the following values: nrtVbr rtVbr
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

juniAtm1483ProfileVccMbs 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.7
Maximum Burst Size, in cells, of this circuit. This parameter is only required when juniAtm1483ProfileVccServiceCategory is configured to have one of the following values: nrtVbr rtVbr
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

juniAtm1483ProfileIfAlias 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.8
This object is an 'alias' name for the interface as specified by a network manager, and provides a non-volatile 'handle' for the interface. This object initializes ifAlias for the interface. Note, all interfaces created through the same profile entry will have identical values for ifAlias.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

juniAtm1483ProfileAdvisoryRxSpeed 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.9
Advisory receive speed, in kilobits per second (kbps), of this subinterface. This object has no impact on forwarding performance but may be used as a hint for the underlying circuit receive speed. A value of 0 indicates that this feature is not enabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtm1483ProfileVccOamAdminStatus 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.10
The administrative state of OAM for the interface identified by this entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER oamAdminStateDisabled(1), oamAdminStateEnabled(2)  

juniAtm1483ProfileVccOamLoopbackFrequency 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.11
The OAM loopback frequency for the interface identified by this entry.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..600  

juniAtm1483ProfileVcClassName 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.12
The name of the ATM VC class assigned to this profile.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

juniAtm1483ProfileAutoConfTable 1.3.6.1.4.1.4874.2.2.58.1.1.2
Configures recognition of incoming data encapsulation types that trigger autoconfiguration on an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtm1483ProfileAutoConfEntry

juniAtm1483ProfileAutoConfEntry 1.3.6.1.4.1.4874.2.2.58.1.1.2.1
Configures recognition of an incoming data encapsulation type that triggers autoconfiguration on an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtm1483ProfileAutoConfEntry  

juniAtm1483ProfileAutoConfId 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.1
The integer identifier associated with this profile. A value for this identifier is determined by locating or creating a profile name in the juniProfileNameTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtm1483ProfileAutoConfEncaps 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.2
The encapsulating protocol type to which the autconfiguration information in this entry applies. The valid values are: ip(0), ppp(1), pppoe(17), bridgedEthernet(19)
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniProfileIfEncaps  

juniAtm1483ProfileAutoConfEnable 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.3
When enabled, permits autoconfiguration of the specified interface when the specified encapsulation is recognized in an incoming data frame. This parameter can only be set when juniAtm1483ProfileAutoConfEncaps is configured to one of the following values: ip(0), ppp(1) pppoe(17), bridgedEthernet(19)
Status: current Access: read-write
OBJECT-TYPE    
  JuniEnable  

juniAtm1483ProfileAutoConfLockoutMin 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.4
The lower bound, in seconds, of the time range used to specify the duration of the lockout of the encapsulation type from recognition for the specified interface. This only takes effect if juniAtm1483ProfileAutoConfEnable is set to enable for the encapsulation type for this interface. The ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type is enabled by default. The initial lockout duration is this object's value and increases exponentially for each failure that occurs for the specified encapsulation type for the specified interface within the greater of 15 minutes and juniAtm1483ProfileAutoConfLockoutMax. The lockout duration for the specified encapsulation type will not exceed juniAtm1483ProfileAutoConfLockoutMax. If the time between creation errors for the specified encapsulation type for the specified interface is greater than the greater of 15 minutes and juniAtm1483ProfileAutoConfLockoutMax, then the lockout duration reverts to this object's value. To disable the ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type for the specified interface, the value of this object and juniAtm1483ProfileAutoConfLockoutMax must be set to 0. It is not recommended that this lockout feature be disabled except for debugging purposes.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..86400  

juniAtm1483ProfileAutoConfLockoutMax 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.5
The upper bound, in seconds, of the time range used to specify the duration of the lockout of the encapsulation type from recognition for the specified interface. This value must equal or exceed the value for juniAtm1483ProfileAutoConfLockoutMin. This only takes effect if juniAtm1483ProfileAutoConfEnable is set to enable for the encapsulation type for this interface. The ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type is enabled by default. The initial lockout duration is juniAtm1483ProfileAutoConfLockoutMin and increases exponentially for each failure that occurs for the specified encapsulation type for the specified interface within the greater of 15 minutes and this object's value. The lockout duration for the specified encapsulation type will not exceed this object's value. If the time between creation errors for the specified encapsulation type for the specified interface is greater than the greater of 15 minutes and this object's value, then the lockout duration reverts to juniAtm1483ProfileAutoConfLockoutMin. To disable the ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type for the specified interface, the value of this object and juniAtm1483ProfileAutoConfLockoutMin must be set to 0. It is not recommended that this lockout feature be disabled except for debugging purposes.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..86400  

juniAtm1483ProfileNestedProfileTable 1.3.6.1.4.1.4874.2.2.58.1.1.3
Specifies nested profiles for incoming data encapsulation types. Entries in this table are created/deleted as a side-effect of corresponding operations to the juniProfileNameTable in the Juniper-PROFILE-MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtm1483ProfileNestedProfileEntry

juniAtm1483ProfileNestedProfileEntry 1.3.6.1.4.1.4874.2.2.58.1.1.3.1
Specifies nested profile for incoming data encapsulation type.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtm1483ProfileNestedProfileEntry  

juniAtm1483ProfileNestedProfileId 1.3.6.1.4.1.4874.2.2.58.1.1.3.1.1
The integer identifier associated with this profile. A value for this identifier is determined by locating or creating a profile name in the juniProfileNameTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtm1483ProfileNestedProfileEncaps 1.3.6.1.4.1.4874.2.2.58.1.1.3.1.2
The encapsulating protocol type to which the nested profile specified in this entry applies. The valid values are: ip(0), ppp(1), pppoe(17), bridgedEthernet(19)
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniProfileIfEncaps  

juniAtm1483ProfileNestedProfileUpperIfProfileName 1.3.6.1.4.1.4874.2.2.58.1.1.3.1.3
The name of profile used for the protocol type specified by juniAtm1483ProfileNestedProfileEncaps.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

juniAtm1483ProfileSubscriberTable 1.3.6.1.4.1.4874.2.2.58.1.1.4
Configures subscriber identity used in circumstances where the remote subscriber's identity cannot be queried directly (e.g. dynamic IPoA operation). Entries in this table are created/deleted as a side-effect of corresponding operations to the juniProfileNameTable in the Juniper-PROFILE-MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtm1483ProfileSubscriberEntry

juniAtm1483ProfileSubscriberEntry 1.3.6.1.4.1.4874.2.2.58.1.1.4.1
Configures subscriber identity used in circumstances where the remote subscriber's identity cannot be queried directly (e.g. dynamic IPoA operation).
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtm1483ProfileSubscriberEntry  

juniAtm1483ProfileSubscriberId 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.1
The integer identifier associated with this profile. A value for this identifier is determined by locating or creating a profile name in the juniProfileNameTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtm1483ProfileSubscriberEncaps 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.2
The encapsulating protocol type to which the subscriber information in this entry applies. The valid values are: ip(0), bridgedEthernet(19)
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniProfileIfEncaps  

juniAtm1483ProfileSubscriberNamePrefix 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.3
If enabled, indicates whether the value of juniSubscriberName is a prefix rather than a full name. This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is configured to one of the following values: ip(0), bridgedEthernet(19) For all other values of juniAtm1483ProfileSubscriberEncaps it returns 'disable'.
Status: current Access: read-write
OBJECT-TYPE    
  JuniEnable  

juniAtm1483ProfileSubscriberName 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.4
If juniAtm1483ProfileSubscriberNamePrefix has the value 'enabled', the value of this object serves as the prefix of a full subscriber name. The full name is constructed by appending local geographic information (slot, port, etc.) that uniquely distinguishes the subscriber. This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is configured to one of the following values: ip(0), bridgedEthernet(19) For all other values of juniAtm1483ProfileSubscriberEncaps it returns an empty string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

juniAtm1483ProfileSubscriberPasswordPrefix 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.5
If enabled, indicates whether the value of juniAtm1483ProfileSubscriberPassword is a prefix rather than a full password. This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is configured to one of the following values: ip(0), bridgedEthernet(19) For all other values of juniAtm1483ProfileSubscriberEncaps it returns an empty string.
Status: current Access: read-write
OBJECT-TYPE    
  JuniEnable  

juniAtm1483ProfileSubscriberPassword 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.6
The subscriber's password. If juniAtm1483ProfileSubscriberPasswordPrefix has the value 'enabled', the value of this object serves as the prefix of a full subscriber password. The full password is constructed by appending local geographic information (slot, port, etc.) that uniquely distinguishes the subscriber. This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is configured to one of the following values: ip(0), bridgedEthernet(19) For all other values of juniAtm1483ProfileSubscriberEncaps it returns an empty string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

juniAtm1483ProfileSubscriberDomain 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.7
The subscriber's domain. This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is configured to one of the following values: ip(0), bridgedEthernet(19) For all other values of juniAtm1483ProfileSubscriberEncaps it returns an empty string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

juniAtm1483ProfileConformance 1.3.6.1.4.1.4874.2.2.58.4
OBJECT IDENTIFIER    

juniAtm1483ProfileCompliances 1.3.6.1.4.1.4874.2.2.58.4.1
OBJECT IDENTIFIER    

juniAtm1483ProfileGroups 1.3.6.1.4.1.4874.2.2.58.4.2
OBJECT IDENTIFIER    

juniAtm1483ProfileCompliance 1.3.6.1.4.1.4874.2.2.58.4.1.1
Obsolete compliance statement for entities which implement the Juniper ATM Profile MIB. This statement became obsolete when ifALias support was added to profile entries.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtm1483ProfileCompliance2 1.3.6.1.4.1.4874.2.2.58.4.1.2
Obsolete compliance statement for entities which implement the Juniper ATM Profile MIB. This statement became obsolete when lockout objects were added to juniAtm1483ProfileAutoConfTable.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtm1483ProfileCompliance3 1.3.6.1.4.1.4874.2.2.58.4.1.3
Obsolete compliance statement for entities which implement the Juniper ATM Profile MIB.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtm1483ProfileCompliance4 1.3.6.1.4.1.4874.2.2.58.4.1.4
The compliance statement for entities which implement the Juniper ATM Profile MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

juniAtm1483ProfileGroup 1.3.6.1.4.1.4874.2.2.58.4.2.1
Obsolete collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product. This group became obsolete when ifALias support was added to profile entries.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtm1483ProfileGroup2 1.3.6.1.4.1.4874.2.2.58.4.2.2
Obolete collection of objects providing management of profile functionalityfor ATM subinterfaces in a Juniper product. This group became obsolete when OAM support was added to profile entries.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtm1483ProfileGroup3 1.3.6.1.4.1.4874.2.2.58.4.2.3
Obsolete collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product. This group became obsolete when ifALias support was added to profile entries.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtm1483ProfileGroup4 1.3.6.1.4.1.4874.2.2.58.4.2.4
Obsolete collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product. This group became obsolete when Encapsulation Type Lockout objects were added to profile entries.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtm1483ProfileGroup5 1.3.6.1.4.1.4874.2.2.58.4.2.5
Obsolete collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtm1483ProfileGroup6 1.3.6.1.4.1.4874.2.2.58.4.2.6
A collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP