ITOUCH-TRAP-MIB
File:
ITOUCH-TRAP-MIB.mib (11799 bytes)
Imported modules
Imported symbols
Defined Values
xTrap |
1.3.6.1.4.1.33.48 |
OBJECT IDENTIFIER |
|
|
|
resourceLacks |
9 |
Indication that the system incremented the
corresponding value of resLacks. The variable is resType
FROM ITOUCH-SYSTEM-MIB. |
TRAP-TYPE |
|
|
|
repeaterRedundancy |
12 |
A new path becomes active within a redundancy group. The
variables are repeaterRedundancyGroupGroupIndex,
repeaterRedundancyGroupOperPath FROM ITOUCH-REPEATER-MIB. |
TRAP-TYPE |
|
|
|
accessViolated |
14 |
Access violation by connected system with Ethernet
address not allowed by repeaterPortAccessTable and
repeaterPortAccessAction. The variable is repeaterPortIndex
FROM ITOUCH-REPEATER-MIB. |
TRAP-TYPE |
|
|
|
portIntegrityLoss |
15 |
This port has lost link integrity. The variables are
repeaterPortIndex, repeaterPortGroupIndex
FROM ITOUCH-REPEATER-MIB. |
TRAP-TYPE |
|
|
|
iTouchRmonAlarm |
17 |
The SNMP trap that is generated when xRmonTrapType
is set to iTouchFormat(2). These traps, like the
RMON standardFormat(1) traps, occur when an alarm
variable crosses its rising or falling threshold
and generates an event configured to send SNMP traps.
The format of the DisplayString embodied by the
trap PDU is identical to that of mbLogDescription.
The actual object identifier is not significant.
The variable is mbLogDescription FROM ITOUCH-RMON-MIB. |
TRAP-TYPE |
|
|
|
memoryCardSlotChange |
18 |
Indication that the card has been added or removed. The
deviceIndex from ITOUCH-BOOT-SERVER-MIB may be included
as a variable in the trap. |
TRAP-TYPE |
|
|
|
lb2ChassisCardSlotChange |
19 |
Indication that the card has been added or removed. The
variable is slotIndex FROM ITOUCH-CHASSIS-MIB. |
TRAP-TYPE |
|
|
|
circuitDialTime |
20 |
Indication that a dialed circuit has reached a threshhold
for the maximum number of minutes that a dialed call may
remain active. The variable is ifIndex FROM RFC1213-MIB. |
TRAP-TYPE |
|
|
|
circuitPerDialTime |
21 |
Indication that a dialed circuit has reached a threshhold
for the maximum number of minutes that a circuit may be
active with dialed calls within a given period.
The variable is ifIndex FROM RFC1213-MIB. |
TRAP-TYPE |
|
|
|
circuitPerDialAttempt |
22 |
Indication that a dialed circuit has reached a threshhold
for the maximum number of dial attempts that a circuit
may make for a given period.
The variable is ifIndex FROM RFC1213-MIB. |
TRAP-TYPE |
|
|
|
fddiPcmStatusChange |
23 |
A fddi port status has changed.
The variable is fddimibPORTPCMState FROM FDDI-SMT73-MIB. |
TRAP-TYPE |
|
|
|
fddiSMTCFStateFailure |
26 |
A fddi station detects that the link is disabled or broken.
The variable is fddimibSMTCFState FROM FDDI-SMT73-MIB. |
TRAP-TYPE |
|
|
|
sysLoginAuthenticationFailed |
28 |
Indicates when and where a user attempted and failed to
access the system. The variables are sysLoginAuthFailureTrapType,
sysLoginAuthTrapIdentity FROM ITOUCH-SYSTEM-MIB. |
TRAP-TYPE |
|
|
|
sensorThresholdExceeded |
29 |
Indication that the temperature or humidity exceeded a threshhold and
the value of the currrent temperature or humidity. Either the
basicTemperatureValue or basicHumidityValue is included
as a variable in the trap to indicate which sensor exceeded its
threshold. These variables are FROM ITOUCH-CHARACTER-MIB. |
TRAP-TYPE |
|
|
|
powerAlarmFuseA |
31 |
Indicates that a fuse from bank A tripped its breaker, or that
it went operational. However, it is unlikely that a trap would
be issued when the fuse starts working. |
TRAP-TYPE |
|
|
|
powerAlarmFuseB |
32 |
Indicates that a fuse from bank B tripped its breaker, or that
it went operational. However, it is unlikely that a trap would
be issued when the fuse starts working. |
TRAP-TYPE |
|
|
|
powerAlarmSupplyA |
33 |
Indicates that power supply A lost or regained power.
However, it is unlikely that a trap would be issued when the
power comes on. |
TRAP-TYPE |
|
|
|
powerAlarmSupplyB |
34 |
Indicates that power supply B lost or regained power.
However, it is unlikely that a trap would be issued when the
power comes on. |
TRAP-TYPE |
|
|
|
portOutputSignalChanged |
36 |
Indicates that an output signal on a port has transitioned to
the state indicated in the variable rs232OutSigState. |
TRAP-TYPE |
|
|
|