ITOUCH-TRAP-MIB

File: ITOUCH-TRAP-MIB.mib (11799 bytes)

Imported modules

RFC-1215 RFC1213-MIB ITOUCH-CHARACTER-MIB
RFC1317-MIB ITOUCH-MIB

Imported symbols

TRAP-TYPE sysObjectID basicContactClosureOrScanPointValue
basicContactClosureOrScanPointName basicPowerStatusFuseA basicPowerStatusFuseB
basicPowerSupplyStatusA basicPowerSupplyStatusB rs232InSigState
rs232OutSigState iTouch

Defined Values

xTrap 1.3.6.1.4.1.33.48
OBJECT IDENTIFIER    

resourceLacks 9
Indication that the system incremented the corresponding value of resLacks. The variable is resType FROM ITOUCH-SYSTEM-MIB.
TRAP-TYPE    

repeaterRedundancy 12
A new path becomes active within a redundancy group. The variables are repeaterRedundancyGroupGroupIndex, repeaterRedundancyGroupOperPath FROM ITOUCH-REPEATER-MIB.
TRAP-TYPE    

accessViolated 14
Access violation by connected system with Ethernet address not allowed by repeaterPortAccessTable and repeaterPortAccessAction. The variable is repeaterPortIndex FROM ITOUCH-REPEATER-MIB.
TRAP-TYPE    

portIntegrityLoss 15
This port has lost link integrity. The variables are repeaterPortIndex, repeaterPortGroupIndex FROM ITOUCH-REPEATER-MIB.
TRAP-TYPE    

iTouchRmonAlarm 17
The SNMP trap that is generated when xRmonTrapType is set to iTouchFormat(2). These traps, like the RMON standardFormat(1) traps, occur when an alarm variable crosses its rising or falling threshold and generates an event configured to send SNMP traps. The format of the DisplayString embodied by the trap PDU is identical to that of mbLogDescription. The actual object identifier is not significant. The variable is mbLogDescription FROM ITOUCH-RMON-MIB.
TRAP-TYPE    

memoryCardSlotChange 18
Indication that the card has been added or removed. The deviceIndex from ITOUCH-BOOT-SERVER-MIB may be included as a variable in the trap.
TRAP-TYPE    

lb2ChassisCardSlotChange 19
Indication that the card has been added or removed. The variable is slotIndex FROM ITOUCH-CHASSIS-MIB.
TRAP-TYPE    

circuitDialTime 20
Indication that a dialed circuit has reached a threshhold for the maximum number of minutes that a dialed call may remain active. The variable is ifIndex FROM RFC1213-MIB.
TRAP-TYPE    

circuitPerDialTime 21
Indication that a dialed circuit has reached a threshhold for the maximum number of minutes that a circuit may be active with dialed calls within a given period. The variable is ifIndex FROM RFC1213-MIB.
TRAP-TYPE    

circuitPerDialAttempt 22
Indication that a dialed circuit has reached a threshhold for the maximum number of dial attempts that a circuit may make for a given period. The variable is ifIndex FROM RFC1213-MIB.
TRAP-TYPE    

fddiPcmStatusChange 23
A fddi port status has changed. The variable is fddimibPORTPCMState FROM FDDI-SMT73-MIB.
TRAP-TYPE    

fddiSMTCFStateFailure 26
A fddi station detects that the link is disabled or broken. The variable is fddimibSMTCFState FROM FDDI-SMT73-MIB.
TRAP-TYPE    

sysLoginAuthenticationFailed 28
Indicates when and where a user attempted and failed to access the system. The variables are sysLoginAuthFailureTrapType, sysLoginAuthTrapIdentity FROM ITOUCH-SYSTEM-MIB.
TRAP-TYPE    

sensorThresholdExceeded 29
Indication that the temperature or humidity exceeded a threshhold and the value of the currrent temperature or humidity. Either the basicTemperatureValue or basicHumidityValue is included as a variable in the trap to indicate which sensor exceeded its threshold. These variables are FROM ITOUCH-CHARACTER-MIB.
TRAP-TYPE    

contactClosureChange 30
Indication that the contact closure transitioned to open or closed.
TRAP-TYPE    

powerAlarmFuseA 31
Indicates that a fuse from bank A tripped its breaker, or that it went operational. However, it is unlikely that a trap would be issued when the fuse starts working.
TRAP-TYPE    

powerAlarmFuseB 32
Indicates that a fuse from bank B tripped its breaker, or that it went operational. However, it is unlikely that a trap would be issued when the fuse starts working.
TRAP-TYPE    

powerAlarmSupplyA 33
Indicates that power supply A lost or regained power. However, it is unlikely that a trap would be issued when the power comes on.
TRAP-TYPE    

powerAlarmSupplyB 34
Indicates that power supply B lost or regained power. However, it is unlikely that a trap would be issued when the power comes on.
TRAP-TYPE    

portInputSignalChanged 35
Indicates that an input signal on a port has transitioned to the state indicated in the variable rs232InSigState.
TRAP-TYPE    

portOutputSignalChanged 36
Indicates that an output signal on a port has transitioned to the state indicated in the variable rs232OutSigState.
TRAP-TYPE