IEEE8021-TEIPS-MIB

File: IEEE8021-TEIPS-MIB.mib (28149 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IEEE8021-TC-MIB
IEEE8021-BRIDGE-MIB SNMPv2-CONF

Imported symbols

MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
Unsigned32 RowStatus StorageType
TruthValue ieee802dot1mibs IEEE8021BridgePortNumber
IEEE8021TeipsIpgConfigActiveRequests IEEE8021TeipsIpgid IEEE8021TeipsIpgConfigAdmin
IEEE8021PbbTeTSidId ieee8021BridgeBaseComponentId MODULE-COMPLIANCE
NOTIFICATION-GROUP OBJECT-GROUP

Defined Types

Ieee8021TeipsIpgEntry  
SEQUENCE    
  ieee8021TeipsIpgid IEEE8021TeipsIpgid
  ieee8021TeipsIpgWorkingMA Unsigned32
  ieee8021TeipsIpgProtectionMA Unsigned32
  ieee8021TeipsIpgWorkingPortNumber IEEE8021BridgePortNumber
  ieee8021TeipsIpgProtectionPortNumber IEEE8021BridgePortNumber
  ieee8021TeipsIpgStorageType StorageType
  ieee8021TeipsIpgRowStatus RowStatus

Ieee8021TeipsTesiEntry  
SEQUENCE    
  ieee8021TeipsTesiIndex Unsigned32
  ieee8021TeipsTesiId IEEE8021PbbTeTSidId
  ieee8021TeipsTesiStorageType StorageType
  ieee8021TeipsTesiRowStatus RowStatus

Ieee8021TeipsCandidatePsEntry  
SEQUENCE    
  ieee8021TeipsCandidatePsIndex Unsigned32
  ieee8021TeipsCandidatePsMA Unsigned32
  ieee8021TeipsCandidatePsPort IEEE8021BridgePortNumber
  ieee8021TeipsCandidatePsOper TruthValue
  ieee8021TeipsCandidatePsStorageType StorageType
  ieee8021TeipsCandidatePsRowStatus RowStatus

Ieee8021TeipsIpgConfigEntry  
SEQUENCE    
  ieee8021TeipsIpgConfigState INTEGER
  ieee8021TeipsIpgConfigCommandStatus IEEE8021TeipsIpgConfigAdmin
  ieee8021TeipsIpgConfigCommandLast IEEE8021TeipsIpgConfigAdmin
  ieee8021TeipsIpgConfigCommandAdmin IEEE8021TeipsIpgConfigAdmin
  ieee8021TeipsIpgConfigActiveRequests IEEE8021TeipsIpgConfigActiveRequests
  ieee8021TeipsIpgConfigWTR Unsigned32
  ieee8021TeipsIpgConfigHoldOff Unsigned32
  ieee8021TeipsIpgM1ConfigState INTEGER
  ieee8021TeipsIpgConfigMWTR Unsigned32
  ieee8021TeipsIpgConfigNotifyEnable TruthValue
  ieee8021TeipsIpgConfigStorageType StorageType

Defined Values

ieee8021TeipsMib 1.3.111.2.802.1.1.24
Copyright (C) IEEE. All Rights Reserved This MIB module is part of IEEE 802.1Q; See the IEEE 802.1Q standard for full legal notices. Unless otherwise indicated, the references in this MIB module are to IEEE 802.1Q-2011 as amended by the following standards: IEEE 802.1az IEEE 802.1bb IEEE 802.1bc IEEE 802.1be
MODULE-IDENTITY    

ieee8021TeipsNotifications 1.3.111.2.802.1.1.24.0
OBJECT IDENTIFIER    

ieee8021TeipsObjects 1.3.111.2.802.1.1.24.1
OBJECT IDENTIFIER    

ieee8021TeipsConformance 1.3.111.2.802.1.1.24.2
OBJECT IDENTIFIER    

ieee8021TeipsIpgTable 1.3.111.2.802.1.1.24.1.1
The IPG table. Each entry in this table corresponds to an Infrastructure Protection Group (IPG) associated with a PBB supporting Infrastructure Protection Switching (IPS).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021TeipsIpgEntry

ieee8021TeipsIpgEntry 1.3.111.2.802.1.1.24.1.1.1
The IPG table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021TeipsIpgEntry  

ieee8021TeipsIpgid 1.3.111.2.802.1.1.24.1.1.1.1
Uniquely identifies an IPG within the PBB.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021TeipsIpgid  

ieee8021TeipsIpgWorkingMA 1.3.111.2.802.1.1.24.1.1.1.2
Identifies the Segment MA that corresponds to the IPG's working entity. The MA index in this column must hold a value that is the value of dot1agCfmStackMaIndex column for some entry in the dot1agCfmStackTable before the RowStatus for this row can be set to Active. Furthermore, this column may not be modified when the RowStatus for this row is Active.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021TeipsIpgProtectionMA 1.3.111.2.802.1.1.24.1.1.1.3
Identifies the Segment MA that corresponds to the IPG's protection entity. The MA index in this column must hold a value that is the value of dot1agCfmStackMaIndex column for some entry in the dot1agCfmStackTable before the RowStatus for this row can be set to Active. Furthermore, this column may not be modified when the RowStatus for this row is Active.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021TeipsIpgWorkingPortNumber 1.3.111.2.802.1.1.24.1.1.1.4
Identifies the local Port associated with the IPG Working Segment.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021TeipsIpgProtectionPortNumber 1.3.111.2.802.1.1.24.1.1.1.5
Identifies the local Port associated with the IPG Protection Segment.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021TeipsIpgStorageType 1.3.111.2.802.1.1.24.1.1.1.6
This object indicates the persistence of this entry. All read-create columns must be writable if this column is set to permanent.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021TeipsIpgRowStatus 1.3.111.2.802.1.1.24.1.1.1.7
The status of this row. The writable columns in a row cannot be changed if the row is active. The TeipsIpgWorkingMA and TeipsIpgProtectionMA columns must be specified before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021TeipsTesiTable 1.3.111.2.802.1.1.24.1.2
The IPG TE-SID table contains identifies the TE service instances associated with an IPG.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021TeipsTesiEntry

ieee8021TeipsTesiEntry 1.3.111.2.802.1.1.24.1.2.1
The TE-IPS TESI entry. Each entry identifies a TESI associated with an IPG.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021TeipsTesiEntry  

ieee8021TeipsTesiIndex 1.3.111.2.802.1.1.24.1.2.1.1
This is an identifier, of local signifigance to a particular PBB-TE TE-SID associated with an IPG.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4294967295  

ieee8021TeipsTesiId 1.3.111.2.802.1.1.24.1.2.1.2
This column holds the TESI identifier corresponding to a TE service instance associated with an IPG.
Status: current Access: read-create
OBJECT-TYPE    
  IEEE8021PbbTeTSidId  

ieee8021TeipsTesiStorageType 1.3.111.2.802.1.1.24.1.2.1.3
This object indicates the persistence of this entry. All read-create columns must be writable for permanent rows.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021TeipsTesiRowStatus 1.3.111.2.802.1.1.24.1.2.1.4
This column holds the status for this row. When the status is active, no columns of this table may be modified. All columns must have a valid value before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021TeipsCandidatePsTable 1.3.111.2.802.1.1.24.1.3
The Candidate PS table lists, in priority order, from highest priority to lowest priority, the Maintenance Associations corresponding to candidate Protection Segments associated with an IPG.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021TeipsCandidatePsEntry

ieee8021TeipsCandidatePsEntry 1.3.111.2.802.1.1.24.1.3.1
A Candidate PS entry. Each entry identifies a candidate Protection Segment associated with an IPG.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021TeipsCandidatePsEntry  

ieee8021TeipsCandidatePsIndex 1.3.111.2.802.1.1.24.1.3.1.1
This is an identifier, of local signifigance to a particular candidate Protection Segment associated with an IPG.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4294967295  

ieee8021TeipsCandidatePsMA 1.3.111.2.802.1.1.24.1.3.1.2
This column holds the candidate Protection Segment MA corresponding to a candidate Protection Segment associated with an IPG.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021TeipsCandidatePsPort 1.3.111.2.802.1.1.24.1.3.1.3
This column holds the Port Number corresponding to the candidate Protection Segment associated with an IPG.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021TeipsCandidatePsOper 1.3.111.2.802.1.1.24.1.3.1.4
This column indicates whether or not the candidate Protection Segment is operational.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ieee8021TeipsCandidatePsStorageType 1.3.111.2.802.1.1.24.1.3.1.5
This object indicates the persistence of this entry. All read-create columns must be writable for permanent rows.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021TeipsCandidatePsRowStatus 1.3.111.2.802.1.1.24.1.3.1.6
This column holds the status for this row. When the status is active, no columns of this table may be modified. All columns must have a valid value before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021TeipsIpgConfigTable 1.3.111.2.802.1.1.24.1.4
The PBB-TE IPS IPG config table contains configuration and status information for each IPG configured in the system. Entries in this table are created implicitly by the creation of entries in the ieee8021TeipsIpgTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021TeipsIpgConfigEntry

ieee8021TeipsIpgConfigEntry 1.3.111.2.802.1.1.24.1.4.1
The IPG confguration table entry. Rows are created in this table implicitly when a row is added to the ieee8021TeipsIpgTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021TeipsIpgConfigEntry  

ieee8021TeipsIpgConfigState 1.3.111.2.802.1.1.24.1.4.1.1
This column indicates the current state of the protection switching state machine for an IPG. The value can be one of the following: workingSegment(1) The protection switching state machine is in the WORKING_PATH state. protectionSegment(2) The protection switching state machine is in the PROTECTION_PATH state. waitToRestore(3) The protection switching state machine is in the WTR state. protAdmin(4) The protection switching state machine is in the PROT_ADMIN state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER workingSegment(1), protectionSegment(2), waitToRestore(3), protAdmin(4)  

ieee8021TeipsIpgConfigCommandStatus 1.3.111.2.802.1.1.24.1.4.1.2
This column indicates the status of administrative commands within the protection group. It reflects the current operational administrative command being acted upon by the IPG.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021TeipsIpgConfigAdmin  

ieee8021TeipsIpgConfigCommandLast 1.3.111.2.802.1.1.24.1.4.1.3
This column indicates the last attempted administrative command applied to the IPG. It is changed whenever a write is made to the CommandAdmin column of this table and is essentially record of the last attempted administrative operation.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021TeipsIpgConfigAdmin  

ieee8021TeipsIpgConfigCommandAdmin 1.3.111.2.802.1.1.24.1.4.1.4
This column is used by the operator to request that the IPG state machine perform some administrative operation. The operator requests a command by writing the command value to this column. The state machine indicates the command that it is performing by setting the value of the CommandStatus column of this table. This column always reads back as clear(1).
Status: current Access: read-create
OBJECT-TYPE    
  IEEE8021TeipsIpgConfigAdmin  

ieee8021TeipsIpgConfigActiveRequests 1.3.111.2.802.1.1.24.1.4.1.5
This column shows the status of active requests associated with the IPG.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021TeipsIpgConfigActiveRequests  

ieee8021TeipsIpgConfigWTR 1.3.111.2.802.1.1.24.1.4.1.6
This column is used to configure the wait-to-restore timer for the IPG operation. The timer may be configured in steps of 1 minute between 5 and 12 minutes, the default being 5. Additionally, the value 0 is used to indicate that the IPG is to operate non-revertively. The value 0 is not permitted if the IPG is configured for M:1 IPS operation.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0 | 5..12  

ieee8021TeipsIpgConfigHoldOff 1.3.111.2.802.1.1.24.1.4.1.7
This column is used to configure the hold off timer. The purpose is to allow IPS to fix the problem before a higher-layer mechanism, such as PBB-TE TESI protection, is invoked or to allow an inner IPG to fix the problem before IPS is invoked by the outer IPG when IPGs are nested. The hold off timer has a period of from 0 to 10 seconds, the default being 0, with a 100ms granularity.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..100  

ieee8021TeipsIpgM1ConfigState 1.3.111.2.802.1.1.24.1.4.1.8
This column indicates the current state of the M:1 protection switching state machine for an IPG if M:1 IPS is supported. The value can be one of the following: psAssigned(1) The protection switching state machine is in the PS_ASSIGNED state. segmentOk(2) The protection switching state machine is in the SEGMENT_OK state. segmentFailed(3) The protection switching state machine is in the SEGMENT_FAILED state. assignNewPs(4) The protection switching state machine is in the ASSIGN_NEW_PS state. revertToBetterPs(5) The protection switching state machine is in the REVERT_T0_BETTER_PS state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psAssigned(1), segmentOk(2), segmentFailed(3), assignNewPs(4), revertToBetterPs(5)  

ieee8021TeipsIpgConfigMWTR 1.3.111.2.802.1.1.24.1.4.1.9
This column is used to configure the M:1 wait-to-restore timer for the IPG operation if M:1 protection is supported. The timer may be configured in steps of 1 minute between 5 and 12 minutes, the default being 5. Additionally, the value 0 is used to indicate that the IPG is to operate non-revertively.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0 | 5..12  

ieee8021TeipsIpgConfigNotifyEnable 1.3.111.2.802.1.1.24.1.4.1.10
This column is used to enable or disable transmission of ieee8021TeipsIpgAdminFailure notifications. These notifications are generated whenever an administrative command cannot be performed by the IPG.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021TeipsIpgConfigStorageType 1.3.111.2.802.1.1.24.1.4.1.11
This object indicates the persistence of this entry. For permanent objects the ieee8021TeipsIpgConfigCommandAdmin column must be writable.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021TeipsIpgAdminFailure 1.3.111.2.802.1.1.24.0.1
An IPG generates this notification whenever an adminisistrative command cannot be executed by the IPS state machine. For example, when a requested manual switch cannot be performed because of a signal failure condition. The management entity receiving the notification can identify the system from the network source address of the notification and can identify the IPG by the indices of the OID of the ieee8021TeipsIpgConfigState variable in the notification: ieee8021BridgeBaseComponentId - Identifies the component on the bridge where the protection group is configured. ieee8021TeipsIpgid - The ID of the protection group.
Status: current Access: read-create
NOTIFICATION-TYPE    

ieee8021TeipsCompliances 1.3.111.2.802.1.1.24.2.1
OBJECT IDENTIFIER    

ieee8021TeipsGroups 1.3.111.2.802.1.1.24.2.2
OBJECT IDENTIFIER    

ieee8021TeipsIpgGroup 1.3.111.2.802.1.1.24.2.2.1
Objects for the IPG group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021TeipsCandidatePsGroup 1.3.111.2.802.1.1.24.2.2.2
Objects for the Candidate PS group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021TeipsIpgTesiGroup 1.3.111.2.802.1.1.24.2.2.3
Objects for the IPG Tuple group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021TeipsIpgConfigManGroup 1.3.111.2.802.1.1.24.2.2.4
Mandatory objects for the TeipsConfiguration group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021TeipsIpgConfigOptGroup 1.3.111.2.802.1.1.24.2.2.5
Optional 0bjects for the TeipsConfiguration group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021TeipsNotificationsGroup 1.3.111.2.802.1.1.24.2.2.6
Objects for the notifications group.
Status: current Access: read-create
NOTIFICATION-GROUP    

ieee8021TeipsCompliance 1.3.111.2.802.1.1.24.2.1.1
The compliance statement for support of the TEIPS MIB module.
Status: current Access: not-accessible
MODULE-COMPLIANCE