IEEE8021-PBBTE-MIB

File: IEEE8021-PBBTE-MIB.mib (36198 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IEEE8021-TC-MIB
IEEE8021-BRIDGE-MIB Q-BRIDGE-MIB IEEE8021-Q-BRIDGE-MIB
SNMPv2-CONF

Imported symbols

MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
Unsigned32 RowStatus StorageType
TruthValue ieee802dot1mibs IEEE8021BridgePortNumber
IEEE8021PbbComponentIdentifier IEEE8021PbbServiceIdentifier IEEE8021PbbTeEsp
IEEE8021PbbTeProtectionGroupActiveRequests IEEE8021PbbTeProtectionGroupId IEEE8021PbbTeProtectionGroupConfigAdmin
IEEE8021PbbTeTSidId IEEE8021VlanIndexOrWildcard ieee8021BridgeBaseComponentId
PortList ieee8021QBridgeVlanCurrentComponentId MODULE-COMPLIANCE
NOTIFICATION-GROUP OBJECT-GROUP

Defined Types

Ieee8021PbbTeProtectionGroupListEntry  
SEQUENCE    
  ieee8021PbbTeProtectionGroupListGroupId IEEE8021PbbTeProtectionGroupId
  ieee8021PbbTeProtectionGroupListMD Unsigned32
  ieee8021PbbTeProtectionGroupListWorkingMA Unsigned32
  ieee8021PbbTeProtectionGroupListProtectionMA Unsigned32
  ieee8021PbbTeProtectionGroupListStorageType StorageType
  ieee8021PbbTeProtectionGroupListRowStatus RowStatus

Ieee8021PbbTeMASharedGroupEntry  
SEQUENCE    
  ieee8021PbbTeMASharedGroupSubIndex Unsigned32
  ieee8021PbbTeMASharedGroupId IEEE8021PbbTeProtectionGroupId

Ieee8021PbbTeTesiEntry  
SEQUENCE    
  ieee8021PbbTeTesiId IEEE8021PbbTeTSidId
  ieee8021PbbTeTesiComponent IEEE8021PbbComponentIdentifier
  ieee8021PbbTeTesiBridgePort IEEE8021BridgePortNumber
  ieee8021PbbTeTesiStorageType StorageType
  ieee8021PbbTeTesiRowStatus RowStatus

Ieee8021PbbTeTeSiEspEntry  
SEQUENCE    
  ieee8021PbbTeTeSiEspEspIndex Unsigned32
  ieee8021PbbTeTeSiEspEsp IEEE8021PbbTeEsp
  ieee8021PbbTeTeSiEspStorageType StorageType
  ieee8021PbbTeTeSiEspRowStatus RowStatus

Ieee8021PbbTeProtectionGroupConfigEntry  
SEQUENCE    
  ieee8021PbbTeProtectionGroupConfigState INTEGER
  ieee8021PbbTeProtectionGroupConfigCommandStatus IEEE8021PbbTeProtectionGroupConfigAdmin
  ieee8021PbbTeProtectionGroupConfigCommandLast IEEE8021PbbTeProtectionGroupConfigAdmin
  ieee8021PbbTeProtectionGroupConfigCommandAdmin IEEE8021PbbTeProtectionGroupConfigAdmin
  ieee8021PbbTeProtectionGroupConfigActiveRequests IEEE8021PbbTeProtectionGroupActiveRequests
  ieee8021PbbTeProtectionGroupConfigWTR Unsigned32
  ieee8021PbbTeProtectionGroupConfigHoldOff Unsigned32
  ieee8021PbbTeProtectionGroupConfigNotifyEnable TruthValue
  ieee8021PbbTeProtectionGroupConfigStorageType StorageType

Ieee8021PbbTeProtectionGroupISidEntry  
SEQUENCE    
  ieee8021PbbTeProtectionGroupISidIndex IEEE8021PbbServiceIdentifier
  ieee8021PbbTeProtectionGroupISidComponentId IEEE8021PbbComponentIdentifier
  ieee8021PbbTeProtectionGroupISidGroupId IEEE8021PbbTeProtectionGroupId
  ieee8021PbbTeProtectionGroupISidStorageType StorageType
  ieee8021PbbTeProtectionGroupISidRowStatus RowStatus

Ieee8021PbbTeBridgeStaticForwardAnyUnicastEntry  
SEQUENCE    
  ieee8021PbbTeBridgeStaticForwardAnyUnicastVlanIndex IEEE8021VlanIndexOrWildcard
  ieee8021PbbTeBridgeStaticForwardAnyUnicastEgressPorts PortList
  ieee8021PbbTeBridgeStaticForwardAnyUnicastForbiddenPorts PortList
  ieee8021PbbTeBridgeStaticForwardAnyUnicastStorageType StorageType
  ieee8021PbbTeBridgeStaticForwardAnyUnicastRowStatus RowStatus

Defined Values

ieee8021PbbTeMib 1.3.111.2.802.1.1.10
Copyright (C) IEEE (2014). All Rights Reserved This version of this MIB module is part of IEEE 802.1Q; See the standard itself for full legal notices. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q-2014
MODULE-IDENTITY    

ieee8021PbbTeNotifications 1.3.111.2.802.1.1.10.0
OBJECT IDENTIFIER    

ieee8021PbbTeObjects 1.3.111.2.802.1.1.10.1
OBJECT IDENTIFIER    

ieee8021PbbTeConformance 1.3.111.2.802.1.1.10.2
OBJECT IDENTIFIER    

ieee8021PbbTeProtectionGroupListTable 1.3.111.2.802.1.1.10.1.1
The PBB-TE Protection group list table. Each entry in this table corresponds to a configured PBB-TE Protection Group configured on the B-Component of an IB-BEB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PbbTeProtectionGroupListEntry

ieee8021PbbTeProtectionGroupListEntry 1.3.111.2.802.1.1.10.1.1.1
The PBB-TE protection group list table entry. Note that the component ID must refer to an B component
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PbbTeProtectionGroupListEntry  

ieee8021PbbTeProtectionGroupListGroupId 1.3.111.2.802.1.1.10.1.1.1.1
The unique identifier for the protection group.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbTeProtectionGroupId  

ieee8021PbbTeProtectionGroupListMD 1.3.111.2.802.1.1.10.1.1.1.2
This refers to the Maintenance Domain that qualifies the WorkingMA and ProtectionMA columns of this table. The MD index in this column must hold a value that matches the in the dot1agCfmStackMdIndex in the dot1agCfmStackTable for the corresponding WorkingMA and ProtectionMA columns of this table. This correspondence must hold for the RowStatus of this row to be set to Active. Furthermore, this column may not be modified while the RowStatus for this row is Active
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PbbTeProtectionGroupListWorkingMA 1.3.111.2.802.1.1.10.1.1.1.3
This refers to the Maintenance Association that refers to the PBB-TE MA that corresponds to the group's working entity. The MA index in this column must hold a value that is the value of dot1agCfmStackMaIndex column for some entry in the dot1agCfmStackTable before the RowStatus for this row can be set to Active. Furthermore, this column may not be modified when the RowStatus for this row is Active.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PbbTeProtectionGroupListProtectionMA 1.3.111.2.802.1.1.10.1.1.1.4
This refers to the Maintenance Association that refers to the PBB-TE MA that corresponds to the group's protection entity. The MA index in this column must hold a value that is the value of dot1agCfmStackMaIndex column for some entry in the dot1agCfmStackTable before the RowStatus for this row can be set to Active. Furthermore, this column may not be modified when the RowStatus for this row is Active.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PbbTeProtectionGroupListStorageType 1.3.111.2.802.1.1.10.1.1.1.5
This object indicates the persistence of this entry. All read-create columns must be writable if this column is set to permanent.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021PbbTeProtectionGroupListRowStatus 1.3.111.2.802.1.1.10.1.1.1.6
The status of this row. The writable columns in a row cannot be changed if the row is active. The PbbTeProtectionGroupListWorkingMA, and PbbTeProtectionGroupListProtectionMA columns must be specified before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021PbbTeMASharedGroupTable 1.3.111.2.802.1.1.10.1.2
This table contains references to all protection groups that share a working or protection entity with a given protection group.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PbbTeMASharedGroupEntry

ieee8021PbbTeMASharedGroupEntry 1.3.111.2.802.1.1.10.1.2.1
The ieee801PbbTeMASharedGroupEntry table. The table is indexed by protection group and by a simple integer. The table lists all protection groups that load share with that group.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PbbTeMASharedGroupEntry  

ieee8021PbbTeMASharedGroupSubIndex 1.3.111.2.802.1.1.10.1.2.1.1
A simple integer to distinguish the members of the set of MAs that comprise the set of load sharing MAs for the specified protection group.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4294967295  

ieee8021PbbTeMASharedGroupId 1.3.111.2.802.1.1.10.1.2.1.2
This column holds the group id of a protection group that shares a working or protection group with the group whose index is the first index of this row.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021PbbTeProtectionGroupId  

ieee8021PbbTeTesiTable 1.3.111.2.802.1.1.10.1.3
The PBB-TE TESI table contains information for each TE Service Instance known to a system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PbbTeTesiEntry

ieee8021PbbTeTesiEntry 1.3.111.2.802.1.1.10.1.3.1
The PBB-TE TESI entry. Each entry maps a TESI to a component and CBP.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PbbTeTesiEntry  

ieee8021PbbTeTesiId 1.3.111.2.802.1.1.10.1.3.1.1
This is the unique identifier for a PBB-TE TE-SID.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbTeTSidId  

ieee8021PbbTeTesiComponent 1.3.111.2.802.1.1.10.1.3.1.2
This is the component upon which the Bridge Port of the TESI is located.
Status: current Access: read-create
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

ieee8021PbbTeTesiBridgePort 1.3.111.2.802.1.1.10.1.3.1.3
This is the Bridge Port of the TESI.
Status: current Access: read-create
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021PbbTeTesiStorageType 1.3.111.2.802.1.1.10.1.3.1.4
This object indicates the persistence of this entry. All read-crate columns must be writable for rows whose StorageType is permanaent.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021PbbTeTesiRowStatus 1.3.111.2.802.1.1.10.1.3.1.5
This column holds the status for this row. When the status is active, no columns of this table may be modified. All columns must have a valid value before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021PbbTeTeSiEspTable 1.3.111.2.802.1.1.10.1.4
The PBB-TE TE-SID table contains information for each TE service instance known to a system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PbbTeTeSiEspEntry

ieee8021PbbTeTeSiEspEntry 1.3.111.2.802.1.1.10.1.4.1
The PBB-TE TE-SID entry. Each entry refers to a TE Service Instance by identifier and contains information about one of the ESPs that comprise this TE Service Instance.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PbbTeTeSiEspEntry  

ieee8021PbbTeTeSiEspEspIndex 1.3.111.2.802.1.1.10.1.4.1.1
This is an identifier, of local signifigance to a particular PBB-TE TE-SID which is used to index all of the ESPs associated with the TE-SID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4294967295  

ieee8021PbbTeTeSiEspEsp 1.3.111.2.802.1.1.10.1.4.1.2
This column holds the ESP identifier for one of the Ethernet Switched Paths that define the TE service instance.
Status: current Access: read-create
OBJECT-TYPE    
  IEEE8021PbbTeEsp  

ieee8021PbbTeTeSiEspStorageType 1.3.111.2.802.1.1.10.1.4.1.3
This object indicates the persistence of this entry. All read-create columns must be writable for permanent rows.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021PbbTeTeSiEspRowStatus 1.3.111.2.802.1.1.10.1.4.1.4
This column holds the status for this row. When the status is active, no columns of this table may be modified. All columns must have a valid value before the row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021PbbTeProtectionGroupConfigTable 1.3.111.2.802.1.1.10.1.5
The PBB-TE Protection group config table contains configuration and status information for each configuration group configured in the system. Entries in this table are created implicitly by the creation of entries in the ieee8021PbbTeProtectionGroupListTable table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PbbTeProtectionGroupConfigEntry

ieee8021PbbTeProtectionGroupConfigEntry 1.3.111.2.802.1.1.10.1.5.1
The protection group confguration table entry. Rows are created in this table implicitly when a row is added to the ieee8021PbbTeProtectionGroupListTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PbbTeProtectionGroupConfigEntry  

ieee8021PbbTeProtectionGroupConfigState 1.3.111.2.802.1.1.10.1.5.1.1
This column indicates the current state of the protection switching state machine for a protection group.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER workingPath(1), protectionPat(2), waitToRestore(3), protAdmin(4)  

ieee8021PbbTeProtectionGroupConfigCommandStatus 1.3.111.2.802.1.1.10.1.5.1.2
This column indicates the status of administrative commands within the protection group. It reflects the current operational administrative command being acted upon by the protection group.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021PbbTeProtectionGroupConfigAdmin  

ieee8021PbbTeProtectionGroupConfigCommandLast 1.3.111.2.802.1.1.10.1.5.1.3
This column indicates the last attempted administrative command applied to the protection group. It is changed whenever a write is made to the CommandAdmin column of this table and is a record of the last attempted administrative operation.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021PbbTeProtectionGroupConfigAdmin  

ieee8021PbbTeProtectionGroupConfigCommandAdmin 1.3.111.2.802.1.1.10.1.5.1.4
This column is used by the operator to request that the protection group state machine perform some administrative operation. The operator requests a command by writing the command value to this column. The state machine indicates the command that it is performing by setting the value of the CommandStatus column of this table. This column always reads back as clear(1).
Status: current Access: read-create
OBJECT-TYPE    
  IEEE8021PbbTeProtectionGroupConfigAdmin  

ieee8021PbbTeProtectionGroupConfigActiveRequests 1.3.111.2.802.1.1.10.1.5.1.5
This column shows the status of active requests within the TE protection group.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021PbbTeProtectionGroupActiveRequests  

ieee8021PbbTeProtectionGroupConfigWTR 1.3.111.2.802.1.1.10.1.5.1.6
This column is used to configure the wait-to-restore timer for the protection group operation. The timer may be configured in steps of 1 minute between 5 and 12 minutes, the default being 5. Additionally, the value 0 is used to indicate that the protection group is to operate non-revertively.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0 | 5..12  

ieee8021PbbTeProtectionGroupConfigHoldOff 1.3.111.2.802.1.1.10.1.5.1.7
This column is used to configure the hold off timer. The purpose is to allow a service layer protection mechanism to have a chance to fix athe problem before switching at the client layer, or to allow an upstream protected domain to switch before a downsream domain. The hold off timer has a period of from 0 to 10 seconds, the default being 0, with a 100ms granularity.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..100  

ieee8021PbbTeProtectionGroupConfigNotifyEnable 1.3.111.2.802.1.1.10.1.5.1.8
This column is used to enable or disable transmission of ieee8021PbbTeProtectionGroupAdminFailure notifications. These notifications are generated whenever an administrative command cannot be performed by the protection group.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PbbTeProtectionGroupConfigStorageType 1.3.111.2.802.1.1.10.1.5.1.9
This object indicates the persistence of this entry. For permanent objects the ieee8021PbbTeProtectionGroupConfigCommandAdmin column must be writable.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021PbbTeProtectionGroupISidTable 1.3.111.2.802.1.1.10.1.6
This table contains entries for each I-SID that is transported over TE-SIDs that belong to protection groups. Each I-SID maps to a single protection group.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PbbTeProtectionGroupISidEntry

ieee8021PbbTeProtectionGroupISidEntry 1.3.111.2.802.1.1.10.1.6.1
The ieee8021PbbTeProtectionGroupISidTable entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PbbTeProtectionGroupISidEntry  

ieee8021PbbTeProtectionGroupISidIndex 1.3.111.2.802.1.1.10.1.6.1.1
This is the I-Sid that is to be mapped to a protection group.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbServiceIdentifier  

ieee8021PbbTeProtectionGroupISidComponentId 1.3.111.2.802.1.1.10.1.6.1.2
This column qualifies the GroupId column to a particular component.
Status: current Access: read-create
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

ieee8021PbbTeProtectionGroupISidGroupId 1.3.111.2.802.1.1.10.1.6.1.3
This column contains the Id of the protection group used to transport the data belonging to the service identified by the I-SID value specified in the ISidIndex column of this table.
Status: current Access: read-create
OBJECT-TYPE    
  IEEE8021PbbTeProtectionGroupId  

ieee8021PbbTeProtectionGroupISidStorageType 1.3.111.2.802.1.1.10.1.6.1.4
This object indicates the persistence of this entry.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021PbbTeProtectionGroupISidRowStatus 1.3.111.2.802.1.1.10.1.6.1.5
This column contains the status for this row. Once active none of the columns in the row may be modified. All columns must be specified when creating the row.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021PbbTeBridgeStaticForwardAnyUnicastTable 1.3.111.2.802.1.1.10.1.7
A table containing forwarding information for each vlan specifying the set of ports to which forwarding of unicast addressed frames for which no more specific forwarding information applies. This is configured statically by management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PbbTeBridgeStaticForwardAnyUnicastEntry

ieee8021PbbTeBridgeStaticForwardAnyUnicastEntry 1.3.111.2.802.1.1.10.1.7.1
Forwarding information for a VLAN, specifying the set of ports to which forwarding of unicast addressed frames for which no more specific forwarding information applies. The EgressPorts and ForbiddenPorts PortList objects, together, implement the PortMap control element listed in 802.1Q 8.8.1.c.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PbbTeBridgeStaticForwardAnyUnicastEntry  

ieee8021PbbTeBridgeStaticForwardAnyUnicastVlanIndex 1.3.111.2.802.1.1.10.1.7.1.1
The VLAN-ID or other identifier refering to the VLAN to which this static filtering entry applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021VlanIndexOrWildcard  

ieee8021PbbTeBridgeStaticForwardAnyUnicastEgressPorts 1.3.111.2.802.1.1.10.1.7.1.2
The complete set of ports to which a unicast addressed frame is to be forwarded. This value is persistent and will be restored upon system reboot. A port may not be added to this set if it is already a member of ieee8021PbbTeBridgeStaticForwardAnyUnicastForbiddenPorts. The default value is a string of zeros of appropriate length. The value of this object MUST be retained across reinitialization of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

ieee8021PbbTeBridgeStaticForwardAnyUnicastForbiddenPorts 1.3.111.2.802.1.1.10.1.7.1.3
The complete set of ports to which a unicast addressed frame is to be filtered. This value is persistent and will be restored upon system reboot. A port may not be added to this set if it is already a member of ieee8021PbbTeBridgeStaticForwardAnyUnicastEgress. The default value is a string of zeros of appropriate length. The value of this object MUST be retained across reinitialization of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

ieee8021PbbTeBridgeStaticForwardAnyUnicastStorageType 1.3.111.2.802.1.1.10.1.7.1.4
The storage type for this row. All read-create columns must be writable for permanent entries.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

ieee8021PbbTeBridgeStaticForwardAnyUnicastRowStatus 1.3.111.2.802.1.1.10.1.7.1.5
This column contains the status for this row.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021PbbTeProtectionGroupAdminFailure 1.3.111.2.802.1.1.10.0.1
A protection group generates this notification whenever an adminisistrative command cannot be executed by the protection state machine. For example, a requested manual switch cannot be performed because of a signal failure condition. The management entity receiving the notification can identify the system from the network source address of the notification and can identify the protection group by the indices of the OID of the ieee8021PbbTeProtectionGroupConfigState variable in the notification: ieee8021BridgeBaseComponentId - Identifies the component on the Bridge where the protection group is configured. ieee8021PbbTeProtectionGroupListGroupId - The id of the protection group.
Status: current Access: read-create
NOTIFICATION-TYPE    

ieee8021PbbTeCompliances 1.3.111.2.802.1.1.10.2.1
OBJECT IDENTIFIER    

ieee8021PbbTeGroups 1.3.111.2.802.1.1.10.2.2
OBJECT IDENTIFIER    

ieee8021PbbTeGroupListGroup 1.3.111.2.802.1.1.10.2.2.1
Objects for the GroupList group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021PbbTeMASharedGroup 1.3.111.2.802.1.1.10.2.2.2
Objects for the MA Load Sharing Table Group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021PbbTeTesiGroup 1.3.111.2.802.1.1.10.2.2.3
Objects for the TE SI group
Status: current Access: read-create
OBJECT-GROUP    

ieee8021PbbTeSiEspGroup 1.3.111.2.802.1.1.10.2.2.4
Objects for the TESI ESP group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021PbbTeProtectionConfigManGroup 1.3.111.2.802.1.1.10.2.2.5
Objects for the PbbTeConfiguration group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021PbbTeProtectionConfigOptGroup 1.3.111.2.802.1.1.10.2.2.6
Objects for the PbbTeConfiguration group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021PbbTeProtectionGroupISidGroup 1.3.111.2.802.1.1.10.2.2.7
Objects for the ieee8021PbbTeProtectionGroupISidGroup group.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021PbbTeFdbGroup 1.3.111.2.802.1.1.10.2.2.8
Fdb extension objects group
Status: current Access: read-create
OBJECT-GROUP    

ieee8021PbbTeNotificationsGroup 1.3.111.2.802.1.1.10.2.2.9
Objects for the notifications group.
Status: current Access: read-create
NOTIFICATION-GROUP    

ieee8021PbbTeCompliance 1.3.111.2.802.1.1.10.2.1.1
The compliance statement for support of the PBB-TE MIB module.
Status: current Access: not-accessible
MODULE-COMPLIANCE