IBM2260-OPT-MIB

File: IBM2260-OPT-MIB.mib (25528 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

Counter enterprises OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

Cdx6500IBM2260ConfigEntry  
SEQUENCE    
  cdx6500IBM2260CfgPortNumber INTEGER
  cdx6500IBM2260CfgPadType INTEGER
  cdx6500IBM2260CfgPortSpeed INTEGER
  cdx6500IBM2260CfgConnType INTEGER
  cdx6500IBM2260CfgNumDevice INTEGER
  cdx6500IBM2260CfgServiceTimer INTEGER
  cdx6500IBM2260CfgThreshCtr INTEGER
  cdx6500IBM2260CfgRespTimeout INTEGER
  cdx6500IBM2260CfgPortSubAddr DisplayString
  cdx6500IBM2260CfgPortOpt DisplayString
  cdx6500IBM2260CfgRestConnDest DisplayString
  cdx6500IBM2260CfgBillRec DisplayString
  cdx6500IBM2260CfgElectricalInterfaceType INTEGER
  cdx6500IBM2260CfgV24ElectricalInterfaceOption INTEGER
  cdx6500IBM2260CfgHighSpeedElectricalInterfaceOption INTEGER

Cdx6500PPSTIBM2260PortEntry  
SEQUENCE    
  cdx6500IBM2260StatPortNumber INTEGER
  cdx6500IBM2260StatPortStatus DisplayString
  cdx6500IBM2260StatPortState DisplayString
  cdx6500IBM2260StatPortSpeed DisplayString
  cdx6500IBM2260StatPortUtilin INTEGER
  cdx6500IBM2260StatPortUtilOut INTEGER
  cdx6500IBM2260StatParityErrors INTEGER
  cdx6500IBM2260StatOverrunErrors INTEGER
  cdx6500IBM2260StatFramingErrors INTEGER
  cdx6500IBM2260StatBCCErrors INTEGER
  cdx6500IBM2260StatNoResponse INTEGER
  cdx6500IBM2260StatCharInTotal INTEGER
  cdx6500IBM2260StatCharOutTotal INTEGER
  cdx6500IBM2260StatCharInSecond INTEGER
  cdx6500IBM2260StatCharOutSecond INTEGER
  cdx6500IBM2260StatPosAckIn INTEGER
  cdx6500IBM2260StatPosAckOut INTEGER
  cdx6500IBM2260StatNegAckIn INTEGER
  cdx6500IBM2260StatNegAckOut INTEGER
  cdx6500IBM2260StatMsgRetran INTEGER

Cdx6500SPCTIBM2260StationEntry  
SEQUENCE    
  cdx6500IBM2260sCfgPortNum INTEGER
  cdx6500IBM2260sCfgStationNum INTEGER
  cdx6500IBM2260sType INTEGER
  cdx6500IBM2260sStationAddr1 DisplayString
  cdx6500IBM2260sStationAddr2 INTEGER
  cdx6500IBM2260sCallMnem DisplayString
  cdx6500IBM2260sStationEnable INTEGER

Defined Values

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500PCTStationProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.3
OBJECT IDENTIFIER    

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500PSTStationProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.3
OBJECT IDENTIFIER    

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

cdx6500PPCTIBM2260PortTable 1.3.6.1.4.1.449.2.1.2.1.1.20
A list of IBM2260 Port configuration entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500IBM2260ConfigEntry

cdx6500PPCTIBM2260PortEntry 1.3.6.1.4.1.449.2.1.2.1.1.20.1
An IBM2260 Configuration Table entry. Each entry contains the configuration parameters for a single IBM2260 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500IBM2260ConfigEntry  

cdx6500IBM2260CfgPortNumber 1.3.6.1.4.1.449.2.1.2.1.1.20.1.1
The port number corresponding to this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500IBM2260CfgPadType 1.3.6.1.4.1.449.2.1.2.1.1.20.1.2
Indicates whether the port is functioning as a Terminal PAD (TPAD) or a Host PAD (HPAD).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tpad(1), hpad(2)  

cdx6500IBM2260CfgPortSpeed 1.3.6.1.4.1.449.2.1.2.1.1.20.1.3
This is the speed of the port in bits per second, when using internal clocking.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER speed1200(4), speed1800(8), speed2400(13), speed4800(14), speed9600(15), speed19200(16), speed7200(99)  

cdx6500IBM2260CfgConnType 1.3.6.1.4.1.449.2.1.2.1.1.20.1.4
Specify the control signal handshake required for a connection to be made to this port: simp - simple, no control signals required. simpa - CTS follows RTS, but no control signals required.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER simp(1), simpa(16)  

cdx6500IBM2260CfgNumDevice 1.3.6.1.4.1.449.2.1.2.1.1.20.1.5
Specifies the number of IBM2260 stations on this line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260CfgServiceTimer 1.3.6.1.4.1.449.2.1.2.1.1.20.1.6
The Service Timer specifies the interval of time in seconds between periodic servicing. Such servicing includes intervals between attempts to establish network connections, intervals between attempts in TPAD to poll terminals that previously failed to respond, and in HPAD this timer is also used to detect host inactivity (i.e. when the host stops polling the station(s)).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260CfgThreshCtr 1.3.6.1.4.1.449.2.1.2.1.1.20.1.7
Indicates number of consecutive errors that can occur before a station is considered down.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260CfgRespTimeout 1.3.6.1.4.1.449.2.1.2.1.1.20.1.8
Specifies the amount of time in msec the PAD allows a terminal, printer or host to respond. As a result, the TPAD may re-transmit the previous message or abort the current procedure. The HPAD aborts the current procedure as though EOT was received, allowing this HPAD station to disconnect it's SVC if the host malfunctions. An HPAD with a response timeout shorter than the hosts ability to respond may result in Inbound Errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260CfgPortSubAddr 1.3.6.1.4.1.449.2.1.2.1.1.20.1.9
Calls addressed to this node and with this subaddress will be routed to this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500IBM2260CfgPortOpt 1.3.6.1.4.1.449.2.1.2.1.1.20.1.10
Select options on this IBM2260 port as follows: NONE - No option specified ORG - Originate calls from this port ACK - DSP End-to-End Acknowledgements are to be used Any combination of above specified by summing (e.g. ORG+ACK).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500IBM2260CfgRestConnDest 1.3.6.1.4.1.449.2.1.2.1.1.20.1.11
All calls originating from this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route calls to port 1, use P1. To route calls to port 2, station 4, use P2S4. Blank this field to disable this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500IBM2260CfgBillRec 1.3.6.1.4.1.449.2.1.2.1.1.20.1.12
This controls whether billing (accounting) records will be created for calls on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

cdx6500IBM2260CfgElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.20.1.13
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type Note: Changing this parameter requires manual settings on SWITCH1: Interface SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 V.24 ON ON ON ON ON OFF OFF OFF V.35,V.36,X.21 OFF OFF OFF OFF OFF ON ON ON
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v24(1), v35(2), v36(3), x21(4)  

cdx6500IBM2260CfgV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.20.1.14
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ri(1), tm(2)  

cdx6500IBM2260CfgHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.20.1.15
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), xover(2)  

cdx6500PPSTIBM2260PortTable 1.3.6.1.4.1.449.2.1.3.1.1.19
A list of IBM2260 Port statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTIBM2260PortEntry

cdx6500PPSTIBM2260PortEntry 1.3.6.1.4.1.449.2.1.3.1.1.19.1
An IBM2260 Statistics Table entry. Each entry contains the statistics for a single IBM2260 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPSTIBM2260PortEntry  

cdx6500IBM2260StatPortNumber 1.3.6.1.4.1.449.2.1.3.1.1.19.1.1
Physical port number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500IBM2260StatPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.19.1.2
Operational Status of the port. The different operational statuses are: UP : At least 1 station is responding to polls. DOWN : None of the stations are responding to polls. DISABLED : The port is disabled by the user.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500IBM2260StatPortState 1.3.6.1.4.1.449.2.1.3.1.1.19.1.3
Current State of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500IBM2260StatPortSpeed 1.3.6.1.4.1.449.2.1.3.1.1.19.1.4
The measured port speed in bits per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER speed1200(1), speed1800(2), speed2400(3), speed4800(4), speed7200(5), speed9600(6), speed19200(7)  

cdx6500IBM2260StatPortUtilin 1.3.6.1.4.1.449.2.1.3.1.1.19.1.5
The amount of the port's bandwidth that is being utilized; because IBM2260 is a half-duplex protocol the utilization is calculated as the sum of the receive and transmit utilization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500IBM2260StatPortUtilOut 1.3.6.1.4.1.449.2.1.3.1.1.19.1.6
The amount of the port's bandwidth that is being utilized; because IBM2260 is a half-duplex protocol the utilization is calculated as the sum of the receive and transmit utilization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500IBM2260StatParityErrors 1.3.6.1.4.1.449.2.1.3.1.1.19.1.7
The number of character parity errors counted by the I/O driver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatOverrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.19.1.8
The number of received character overruns counted by the I/O driver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatFramingErrors 1.3.6.1.4.1.449.2.1.3.1.1.19.1.9
The number of asynchronous chracters received which violated the character framing of start and stop bits. Note, this statistic is only valid if the port is configured for ASYNC line interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatBCCErrors 1.3.6.1.4.1.449.2.1.3.1.1.19.1.10
The number of BCC errors counted by the I/O driver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatNoResponse 1.3.6.1.4.1.449.2.1.3.1.1.19.1.11
The number of times the response timer has expired.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatCharInTotal 1.3.6.1.4.1.449.2.1.3.1.1.19.1.12
Total number of chracters received to present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.19.1.13
Total number of chracters transmitted to present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatCharInSecond 1.3.6.1.4.1.449.2.1.3.1.1.19.1.14
Average number of characters received to present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatCharOutSecond 1.3.6.1.4.1.449.2.1.3.1.1.19.1.15
Average number of characters transmitted to present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatPosAckIn 1.3.6.1.4.1.449.2.1.3.1.1.19.1.16
Number of ACKs received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatPosAckOut 1.3.6.1.4.1.449.2.1.3.1.1.19.1.17
Number of ACKs transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatNegAckIn 1.3.6.1.4.1.449.2.1.3.1.1.19.1.18
Number of NAKs received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatNegAckOut 1.3.6.1.4.1.449.2.1.3.1.1.19.1.19
Number of NAKs transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500IBM2260StatMsgRetran 1.3.6.1.4.1.449.2.1.3.1.1.19.1.20
Number of messages retransmitted due to NAKs or timeouts to present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500SPCTIBM2260StationTable 1.3.6.1.4.1.449.2.1.2.1.3.6
All of the configuration parameters relevant to the IBM2260 Station table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPCTIBM2260StationEntry

cdx6500SPCTIBM2260StationEntry 1.3.6.1.4.1.449.2.1.2.1.3.6.1
A row of IBM2260 station configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500SPCTIBM2260StationEntry  

cdx6500IBM2260sCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.3.6.1.1
Port number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500IBM2260sCfgStationNum 1.3.6.1.4.1.449.2.1.2.1.3.6.1.2
Station number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

cdx6500IBM2260sType 1.3.6.1.4.1.449.2.1.2.1.3.6.1.3
single - configures a single station addressable by the ADDR1-ADDR2 address pair. group - configures a group of stations addressable by the ADDR1 address character, but ADDR2 is assumed to be 40H, 41H, 42H and 43H. This type is intended for support of DataTroll devices. NOTE: `group' Station should not be used when the BSC3270-IBM2260 protocol Interoperation is being used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER single(1), group(2)  

cdx6500IBM2260sStationAddr1 1.3.6.1.4.1.449.2.1.2.1.3.6.1.4
This is the first byte of this Station's address. The Station address consists of two hexadecimal digits. The valid range for a digit is: 20-7F;
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500IBM2260sStationAddr2 1.3.6.1.4.1.449.2.1.2.1.3.6.1.5
This is the second byte of this Station's address. The Station address consists of two hexadecimal digits. The valid range for a digit is: 20-7F
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500IBM2260sCallMnem 1.3.6.1.4.1.449.2.1.2.1.3.6.1.6
This mnemonic name is used if this port is configured for originating connection requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500IBM2260sStationEnable 1.3.6.1.4.1.449.2.1.2.1.3.6.1.7
This parameter is used to disable/enable a station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)