IB-SMA-MIB

File: IB-SMA-MIB.mib (111449 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMP-FRAMEWORK-MIB
SNMPv2-CONF IB-TC-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
NOTIFICATION-TYPE Unsigned32 TruthValue
SnmpAdminString MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP IbDataPort IbDataPortAndInvalid
IbGuid IbUnicastLid IbMulticastLid
IbSmPortList infinibandMIB

Defined Types

IbSmaGuidInfoEntry  
SEQUENCE    
  ibSmaGuidPortIndex IbDataPort
  ibSmaGuidIndex Unsigned32
  ibSmaGuidVal IbGuid

IbSmaPortInfoEntry  
SEQUENCE    
  ibSmaPortIndex IbDataPort
  ibSmaPortLinkWidthEnabled INTEGER
  ibSmaPortLinkWidthSupported INTEGER
  ibSmaPortLinkWidthActive INTEGER
  ibSmaPortLinkSpeedSupported INTEGER
  ibSmaPortLinkState INTEGER
  ibSmaPortPhysState INTEGER
  ibSmaPortLinkDownDefaultState INTEGER
  ibSmaPortLidMaskCount Unsigned32
  ibSmaPortLinkSpeedActive INTEGER
  ibSmaPortLinkSpeedEnabled INTEGER
  ibSmaPortNeighborMtu INTEGER
  ibSmaPortVirtLaneSupport INTEGER
  ibSmaPortVlHighPriorityLimit Unsigned32
  ibSmaPortVlArbHighCapacity Unsigned32
  ibSmaPortVlArbLowCapacity Unsigned32
  ibSmaPortMtuCapacity INTEGER
  ibSmaPortVlStallCount Unsigned32
  ibSmaPortHeadOfQueueLife Unsigned32
  ibSmaPortOperationalVls INTEGER
  ibSmaPortPartEnforceInbound TruthValue
  ibSmaPortPartEnforceOutbound TruthValue
  ibSmaPortFilterRawPktInbound TruthValue
  ibSmaPortFilterRawPktOutbound TruthValue
  ibSmaPortLocalPhysErrorThreshold Unsigned32
  ibSmaPortOverrunErrorThreshold Unsigned32

IbSmaPKeyEntry  
SEQUENCE    
  ibSmaPKeyIBAPortIndex IbDataPortAndInvalid
  ibSmaPKeyIndex Unsigned32
  ibSmaPKeyMembership INTEGER
  ibSmaPKeyBase Unsigned32

IbSmaSL2VLMapEntry  
SEQUENCE    
  ibSmaIBAOutPortIndex IbDataPortAndInvalid
  ibSmaIBAInPortIndex IbDataPortAndInvalid
  ibSmaServiceLevelIndex Unsigned32
  ibSmaVirtualLane Unsigned32

IbSmaHiPriVlArbEntry  
SEQUENCE    
  ibSmaHiPriIBAPortIndex IbDataPort
  ibSmaHiPriNIndex Unsigned32
  ibSmaHiPriVirtLane Unsigned32
  ibSmaHiPriWeight Unsigned32

IbSmaLowPriVlArbEntry  
SEQUENCE    
  ibSmaLowPriIBAPortIndex IbDataPort
  ibSmaLowPriNIndex Unsigned32
  ibSmaLowPriVirtLane Unsigned32
  ibSmaLowPriWeight Unsigned32

IbSmaLinForEntry  
SEQUENCE    
  ibSmaLinDestDLIDIndex IbUnicastLid
  ibSmaLinForwEgressPort IbDataPortAndInvalid

IbSmaRandomForwardingEntry  
SEQUENCE    
  ibSmaRandomForwardingPortIndex IbDataPort
  ibSmaRandomDestLID Unsigned32
  ibSmaRandomForwEgressPort IbDataPort
  ibSmaRandomLMC Unsigned32
  ibSmaRandomIsValid TruthValue

IbSmaMulForEntry  
SEQUENCE    
  ibSmaMulDestDLIDIndex IbMulticastLid
  ibSmaMulForwMask IbSmPortList

IbSmaSmInfoEntry  
SEQUENCE    
  ibSmaSmInfoPortIndex IbDataPort
  ibSmaSmGuid IbGuid
  ibSmaSmSmKey OCTET STRING
  ibSmaSmSmpCount Counter32
  ibSmaSmPriority Unsigned32
  ibSmaSmState INTEGER

IbSmaVendDiagInfoEntry  
SEQUENCE    
  ibSmaVendDiagPortIndex IbDataPortAndInvalid
  ibSmaPortGenericDiagCode INTEGER
  ibSmaPortVendorDiagCode Unsigned32
  ibSmaPortVendorDiagIndexFwd TruthValue
  ibSmaPortVendorDiagData OCTET STRING

IbSmaLedInfoEntry  
SEQUENCE    
  ibSmaLedIndex IbDataPort
  ibSmaLedState INTEGER

Defined Values

ibSmaMIB 1.3.6.1.3.117.3
Copyright (C) The Internet Society (2005). The initial version of this MIB module was published in RFC XXXX; for full legal notices see the RFC itself. Supplementary information may be available on http://www.ietf.org/copyrights/ianamib.html. This module contains managed object definitions for the Subnet Management Agent instrumentation for an InfiniBand Subnet Management Agent (SMA).
MODULE-IDENTITY    

ibSmaObjects 1.3.6.1.3.117.3.1
OBJECT IDENTIFIER    

ibSmaNotifications 1.3.6.1.3.117.3.2
OBJECT IDENTIFIER    

ibSmaConformance 1.3.6.1.3.117.3.3
OBJECT IDENTIFIER    

ibSmaNodeInfo 1.3.6.1.3.117.3.1.1
OBJECT IDENTIFIER    

ibSmaNodeString 1.3.6.1.3.117.3.1.1.1
The node description. This is the Node description string from the NodeDescription attribute. The contents of the NodeDescription attribute is the same for all ports on a node.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

ibSmaNodeBaseVersion 1.3.6.1.3.117.3.1.1.2
The supported Management Datagram (MAD) base version. This value indicates that the node supports up to and including this version. This value is the same for all ports on a node. (NOTE: for InfiniBand Release 1 this value should be set to 1.)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..255  

ibSmaNodeClassVersion 1.3.6.1.3.117.3.1.1.3
The supported Subnet Management Class (SMP) version. This value indicates that the node supports up to and including this version. This value is the same for all ports on a node. (NOTE: for InfiniBand Release 1 this value should be set to 1.)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..255  

ibSmaNodeType 1.3.6.1.3.117.3.1.1.4
Type of IBA device this SMA is supporting. InfiniBand types are 1: Channel Adapter 2: Switch 3: Router 0,4-255: reserved
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER channelAdapter(1), switch(2), router(3), reserved(4)  

ibSmaNodeNumPorts 1.3.6.1.3.117.3.1.1.5
The number of physical InfiniBand ports on this node.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..254  

ibSmaSystemImageGuid 1.3.6.1.3.117.3.1.1.6
The GUID of this node that associates this node with other nodes in the same administrative domain. These nodes are controlled by common supervisory code. This object provides a way for system software to indicate the availability of multiple paths to the same destination via multiple nodes. If this value is 0, there is no association. This object may be equal to the ibSmaNodeGuid of one of the associated nodes if that node is not field-replaceable.
Status: current Access: read-only
OBJECT-TYPE    
  IbGuid  

ibSmaNodeGuid 1.3.6.1.3.117.3.1.1.7
The GUID of this node. The node can be a Host Channel Adpater (HCA), Terminal Channel Adapter (TCA), switch, or router. All ports on the same node shall report the same NodeGUID value. This provides a means for uniquely identifying a node within a subnet and helps to determine the co-location of the ports.
Status: current Access: read-only
OBJECT-TYPE    
  IbGuid  

ibSmaNodePortGuid 1.3.6.1.3.117.3.1.1.8
The node port GUID. One port within a node can return the NodeGUID as its PortGUID if the port is an integral part of the node and is not field-replaceable.
Status: current Access: read-only
OBJECT-TYPE    
  IbGuid  

ibSmaNodePartitionTableNum 1.3.6.1.3.117.3.1.1.9
Number of entries in the Partition Table for CA, router, and the switch management port. This is at a minimum set to 1 for all nodes including switches. This value shall be the same for all ports on a node.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..65535  

ibSmaNodeDeviceId 1.3.6.1.3.117.3.1.1.10
Device ID information as assigned by the device manufacturer. This value shall be the same for all ports on a node.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

ibSmaNodeRevision 1.3.6.1.3.117.3.1.1.11
Manufacturer assigned device revision. This value shall be the same for all ports on a node.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

ibSmaNodeLocalPortNumOrZero 1.3.6.1.3.117.3.1.1.12
The number of the IBA port which received this SNMP request. If the port is unknown a 0 is returned.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..254  

ibSmaNodeVendorId 1.3.6.1.3.117.3.1.1.13
IEEE specified device vendor identifier. This value shall be the same for all ports on a node.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

ibSmaNodeLid 1.3.6.1.3.117.3.1.1.14
Local Identifier value. Used for notification var bind list object. Retrieved from InfiniBand traps 128, 129, 130, 131, 144, 145, 256, 257, 258, and 259.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..65535  

ibSmaNodePortNum 1.3.6.1.3.117.3.1.1.15
Port number. Used for notification var bind list object. Retrieved from InfiniBand traps 129, 130, 131, and 259.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  IbDataPort  

ibSmaNodeMethod 1.3.6.1.3.117.3.1.1.16
Method. Used for notification var bind list object. Retrieved from InfiniBand trap 256.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..255  

ibSmaNodeAttributeId 1.3.6.1.3.117.3.1.1.17
Attribute ID. Used for notification var bind list object. Retrieved from InfiniBand trap 256.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..65535  

ibSmaNodeAttributeModifier 1.3.6.1.3.117.3.1.1.18
Attribute Modifier. Used for notification var bind list object. Retrieved from InfiniBand trap 256.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..4294967295  

ibSmaNodeKey 1.3.6.1.3.117.3.1.1.19
M_Key, Q_Key or P_Key. Used for notification var bind list object. Retrieved from InfiniBand traps 256, 257, 258, and 259. Note: If it is a P_Key, the 16 most significant bits of the field shall be set to 0 and the least significant bits of the field will be set to the P_Key.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(8)  

ibSmaNodeLid2 1.3.6.1.3.117.3.1.1.20
To Local Identifier (LID). Used for notification var bind list object. Retrieved from InfiniBand traps 257, 258, and 259.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..65535  

ibSmaNodeServiceLevel 1.3.6.1.3.117.3.1.1.21
Service Level. Used for notification var bind list object. Retrieved from InfiniBand traps 257, 258, and 259.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..15  

ibSmaNodeQueuePair1 1.3.6.1.3.117.3.1.1.22
Queue Pair (QP) 1. Used for notification var bind list object. Retrieved from InfiniBand traps 257, 258, and 259.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..16777215  

ibSmaNodeQueuePair2 1.3.6.1.3.117.3.1.1.23
Queue Pair (QP) 2. Used for notification var bind list object. Retrieved from InfiniBand traps 257, 258, and 259.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..16777215  

ibSmaNodeGid1 1.3.6.1.3.117.3.1.1.24
Global Identifier 1. Used for notification var bind list object. Retrieved from InfiniBand traps 64, 65, 66, 67, 257, 258, and 259. Note: If no Global Routing Header (GRH) is present in the offending packet, this value will be all zeros.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(16)  

ibSmaNodeGid2 1.3.6.1.3.117.3.1.1.25
Global Identifier 2. Used for notification var bind list object. Retrieved from InfiniBand traps 257, 258, and 258. Note: If no GRH is present in the offending packet, this value will be all zeros.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(16)  

ibSmaNodeCapMask 1.3.6.1.3.117.3.1.1.26
Contents of Capability Mask. Retrieved from InfiniBand trap 144.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(4)  

ibSmaNodeSwitchLid 1.3.6.1.3.117.3.1.1.27
The switch Local Identifier (LID). Used for notification var bind list object. Retrieved from InfiniBand traps 259.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..65535  

ibSmaNodeDataValid 1.3.6.1.3.117.3.1.1.28
Data valid field retrieved from InfiniBand trap 259. It is a bit mask. If the bit is set, the field is valid. bit 0: LIDADDR1 bit 1: LIDADDR2 bit 2: PKEY bit 3: SL bit 4: QP1 bit 5: QP2 bit 6: GIDADDR1 bit 7: GIDADDR2 bit 8-15: reserved (0).
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  BITS lidaddr1(0), lidaddr2(1), pkey(2), sl(3), qp1(4), qp2(5), gidaddr1(6), gidaddr2(7)  

ibSmaSwitchInfo 1.3.6.1.3.117.3.1.2
OBJECT IDENTIFIER    

ibSmaSwLinearFdbTableNum 1.3.6.1.3.117.3.1.2.1
Number of entries in the Linear Forwarding Data Base. This is the number of entries supported in the Linear Unicast Forwarding Table (starting at LID=0x0000 and going up). The InfiniBand SwitchInfo component is called LinearFDBCap. When the count is 0, this indicates that there is no Linear Forwarding Database present.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..49151  

ibSmaSwRandomFdbTableNum 1.3.6.1.3.117.3.1.2.2
Number of entries in the Random Forwarding Data Base. This is the number of entries supported in the Random Unicast Forwarding Table. The InfiniBand SwitchInfo component is called RandomFDBCap. When the count is 0, this indicates that there is no Random Forwarding Database present.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..49151  

ibSmaSwMulticastFdbTableNum 1.3.6.1.3.117.3.1.2.3
Number of entries in the Multicast Forwarding Data Base. This is the number of entries supported in the Multicast Forwarding Table (starting at LID=0xC000 and going up). The InfiniBand SwitchInfo component is called MulticastFDBCap.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..16383  

ibSmaSwLinearFdbTop 1.3.6.1.3.117.3.1.2.4
Indicates the top of the linear forwarding database. Packets received with unicast DLIDs greater than this value are discarded by the switch. A valid LinearFdbTop is less than LinearFdbCap. This component applies only to switches that implement linear forwarding tables and is ignored by switches that implement random forwarding tables. For the latter cases a 0 is returned.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..49151  

ibSmaSwDefaultPort 1.3.6.1.3.117.3.1.2.5
Default forwarding port for unicast packets from the other ports whose DLID does not exist in the random forwarding table. If the port number is unknown, a 0 is returned.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..254  

ibSmaSwDefMcastPriPort 1.3.6.1.3.117.3.1.2.6
Default forwarding port for multicast packets from the other ports whose DLID does not exist in the forwarding table. If port number is unknown, a 0 is returned.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..254  

ibSmaSwDefMcastNotPriPort 1.3.6.1.3.117.3.1.2.7
Forward to this port all the multicast packets from the Default Primary port whose DLID does not exist in the forwarding table. If it is unknown, a 0 is returned.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..254  

ibSmaSwLifeTimeValue 1.3.6.1.3.117.3.1.2.8
Reports the time a packet can live in the switch. This Lifetime Value (LV) is used as a parameter to calculate Switch Lifetime Limit (SLL) value. To calculate a valid SLL, the LV must be between 0 and 19, inclusive. If the LV value is greater than 19, the SLL is to be interpreted as infinite.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..20  

ibSmaSwPortStateChange 1.3.6.1.3.117.3.1.2.9
This object is set to true(1) whenever the PortState component makes any of the following state changes in the link finite state machine (FSM): Down --> Initialize, Initialize --> Down, Armed --> Down, or Active --> Down
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaSwLidsPerPort 1.3.6.1.3.117.3.1.2.10
Specifies the number of LID/Link Mask Control (LMC) combinations that may be assigned to a given external port for switches that support the Random Forwarding table.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

ibSmaSwPartitionEnforceNum 1.3.6.1.3.117.3.1.2.11
Specifies the number of entries in the partition enforcement table per physical IBA port. The 0 value indicates that partition enforcement is not supported by the switch.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

ibSmaSwInboundEnforceCap 1.3.6.1.3.117.3.1.2.12
Flag that indicates whether the switch is capable of partition enforcement on received packets.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaSwOutboundEnforceCap 1.3.6.1.3.117.3.1.2.13
Flag that indicates whether the switch is capable of partition enforcement on transmitted packets.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaSwFilterRawPktInputCap 1.3.6.1.3.117.3.1.2.14
Flag to indicate whether the switch is capable of raw packet enforcement on received packets.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaSwFilterRawPktOutputCap 1.3.6.1.3.117.3.1.2.15
Flag to indicate whether the switch is capable of raw packet enforcement on transmitted packets.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaSwEnhancedPort0 1.3.6.1.3.117.3.1.2.16
Flag to indicate whether switch port 0 supports enhanced functions (TCA port). If false, switch port 0 is a base switch port 0.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaGuidInfo 1.3.6.1.3.117.3.1.3
OBJECT IDENTIFIER    

ibSmaGuidInfoTable 1.3.6.1.3.117.3.1.3.1
A table containing SMA GUID information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaGuidInfoEntry

ibSmaGuidInfoEntry 1.3.6.1.3.117.3.1.3.1.1
A conceptual row of the ibSmaGuidInfoTable containing information about a particular GUID entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaGuidInfoEntry  

ibSmaGuidPortIndex 1.3.6.1.3.117.3.1.3.1.1.1
Index that identifies IB port associated with this GUID table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPort  

ibSmaGuidIndex 1.3.6.1.3.117.3.1.3.1.1.2
Index that identifies the GUID entry for this port. For any IB port there can be multiple 64 bit GUIDs assigned. The maximum number is implementation dependent (up to 255). If the port does not have a GUID assigned to it, the row will have 1 entry with a ibSmaGuidVal value of zeroes.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..255  

ibSmaGuidVal 1.3.6.1.3.117.3.1.3.1.1.3
A Global Unique Identifier (GUID) for this port entity.
Status: current Access: read-only
OBJECT-TYPE    
  IbGuid  

ibSmaMgmtPortInfo 1.3.6.1.3.117.3.1.4
OBJECT IDENTIFIER    

ibSmaPortMKey 1.3.6.1.3.117.3.1.4.1
The 8-byte management key that is kept locally for the management port. If the value is 0's, no authentication is done.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

ibSmaPortGidPrefix 1.3.6.1.3.117.3.1.4.2
GID prefix for this port.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

ibSmaPortLid 1.3.6.1.3.117.3.1.4.3
The base LID of this port.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..49151  

ibSmaPortMasterSmLid 1.3.6.1.3.117.3.1.4.4
The LID of the master SM that is managing this port.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..49151  

ibSmaPortIsSubnetManager 1.3.6.1.3.117.3.1.4.5
Capability flag for this node: Is Subnet Manager?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsNoticeSupported 1.3.6.1.3.117.3.1.4.6
Capability flag for this node: Are Notices Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsTrapSupported 1.3.6.1.3.117.3.1.4.7
Capability flag for this node: Are IBA Traps Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsAutoMigrateSupported 1.3.6.1.3.117.3.1.4.8
Capability flag for this node: Is Automatic Migration Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsSlMappingSupported 1.3.6.1.3.117.3.1.4.9
Capability flag for this node: Is SL Mapping Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsMKeyNvram 1.3.6.1.3.117.3.1.4.10
Capability flag for this node: Is M_Key in NVRAM?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsPKeyNvram 1.3.6.1.3.117.3.1.4.11
Capability flag for this node: Is P_Key in NVRAM?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsLedInfoSupported 1.3.6.1.3.117.3.1.4.12
Capability flag for this node: Is LED Information Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsSmDisabled 1.3.6.1.3.117.3.1.4.13
Capability flag for this node: Is Subnet Manager Disabled?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsSysImgGuidSupported 1.3.6.1.3.117.3.1.4.14
Capability flag for this node: Is System Image GUID Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsPKeyExtPortTrapSup 1.3.6.1.3.117.3.1.4.15
Capability flag for this node: Is P_Key Switch External Port Trap supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsCommManageSupported 1.3.6.1.3.117.3.1.4.16
Capability flag for this node: Is Communication Management Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsSnmpTunnelSupported 1.3.6.1.3.117.3.1.4.17
Capability flag for this node: Is SNMP Tunneling Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsReinitSupported 1.3.6.1.3.117.3.1.4.18
Capability flag for this node: Is Reinitialization Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsDevManageSupported 1.3.6.1.3.117.3.1.4.19
Capability flag for this node: Is Device Management Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsVendorClassSupported 1.3.6.1.3.117.3.1.4.20
Capability flag for this node: Is Vendor Class Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsDrNoticeSupported 1.3.6.1.3.117.3.1.4.21
Capability flag for this node: Is DR Notice Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsCapMaskNoticSupported 1.3.6.1.3.117.3.1.4.22
Capability flag for this node: Is Capability Mask Notice Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortIsBootMgmtSupported 1.3.6.1.3.117.3.1.4.23
Capability flag for this node: Is Boot Management Supported?
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortMKeyLeasePeriod 1.3.6.1.3.117.3.1.4.24
Specifies the initial value of the lease period timer (in seconds). The lease period is the length of time that the M_Key Protection bits are to remain non-zero after a SubnSet(PortInfo) fails the M_Key authentication check. When the value is 0, the lease period shall never expire.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

ibSmaPortMKeyProtectBits 1.3.6.1.3.117.3.1.4.25
Management Key (M_Key) protection bits.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noMKeyProtection(1), succeedWithReturnKey(2), succeedWithReturnZeroes(3), failOnNoMatch(4)  

ibSmaPortMasterSmSl 1.3.6.1.3.117.3.1.4.26
The administrative Service Level of the master SM that is managing this port.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..15  

ibSmaPortInitTypeLoad 1.3.6.1.3.117.3.1.4.27
The initialization type flags indicate the type of initialization requested by this port before SM moves it to Active or Armed state. Initialization Type flag: NoLoad. If the value is false(2), the attributes should be initialized. If the value is true(1), no data should be loaded into the attributes at all, asserting that the last-loaded data still exists and is valid.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortInitTypeContent 1.3.6.1.3.117.3.1.4.28
Initialization Type flag: PreserveContent. If the value is false(2), the port makes no request regarding the content of the data that is loaded into its attributes. If it is true(1), the port is requesting that all such data, if loaded, be set to the most recent content loaded by the SM.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortInitTypePresence 1.3.6.1.3.117.3.1.4.29
Initialization Type flag: PreservePresence. If the value is false(2), the port is requesting that all settable SA attributes referencing this port be removed prior to activating this port and Traps 64/65 be sent. If the value is true(1), the port is requesting that all such data be preserved, and that the traps not be sent.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortInitTypeResuscitate 1.3.6.1.3.117.3.1.4.30
Initialization Type flag: DoNotResuscitate. If the value is false(2), ibSmaPortInitTypeLoad, ibSmaPortInitTypeContent, and ibSmaPortInitTypePresence ARE valid. If the value is true(1), ibSmaPortInitTypeLoad, ibSmaPortInitTypeContent, and ibSmaPortInitTypePresence ARE NOT valid. The port is requesting that reinitialization of this port and the in/out of service traps (64/65) be delayed until this flag is set to false(1).
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortInitNoLoadReply 1.3.6.1.3.117.3.1.4.31
The Init Reply flags are written by the SM prior to changing the port to Active or Armed state. Initialization Type Reply flag: NoLoadReply. If this value is false(2), the port attributes were initialized. If the value is true(1), no data was loaded into the port attributes.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortInitPreserveContReply 1.3.6.1.3.117.3.1.4.32
Initialization Type flag: PreserveContentReply. If this value is false(2), no information is available regarding the content of the data loaded into the port attributes. If the value is true(1), the data loaded into the port attributes was set to the content most recently loaded by the SM.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortInitPreservePresReply 1.3.6.1.3.117.3.1.4.33
Initialization Type Reply flag: PreservePresenceReply. If this value is false(2), all settable SA attributes referencing this port were removed prior to activating this port and the in/out service traps 64 and 65 were sent. If the value is true(1), all such data existing when this port was last active was not removed and the traps 64/65 were not sent.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortMKeyViolations 1.3.6.1.3.117.3.1.4.34
Counts the number of SMP packets that have been received at this port that have invalid M_Keys. This object is a latching gauge, in that whenever the maximum gauge value is encountered (i.e., the count reaches all 1's), the SMA must reset the gauge to 0, before this object begins incrementing its count again.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ibSmaPortPKeyViolations 1.3.6.1.3.117.3.1.4.35
Counts the number of SMP packets that have been received at this port that have invalid P_Keys. This object is a latching gauge, in that whenever the maximum gauge value is encountered (i.e., the count reaches all 1's), the SMA must reset the gauge to 0, before this object begins incrementing its count again.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ibSmaPortQKeyViolations 1.3.6.1.3.117.3.1.4.36
Counts the number of SMP packets that have been received at this port that have invalid Q_Keys. This object is a latching gauge, in that whenever the maximum gauge value is encountered (i.e., the count reaches all 1's), the SMA must reset the gauge to 0, before this object begins incrementing its count again.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ibSmaPortNumGuid 1.3.6.1.3.117.3.1.4.37
Number of GUID entries supported in the GUIDInfo attribute for this port found in the ibSmaGuidInfoTable.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

ibSmaPortSubnetTimeout 1.3.6.1.3.117.3.1.4.38
Specifies the maximum expected subnet propagation delay, which depends upon the configuration of the switches, to reach any other port in the subnet and shall also be used to determine the maximum rate which SubnTraps() can be sent from this port by the SMA.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..31  

ibSmaPortResponseTimeValue 1.3.6.1.3.117.3.1.4.39
Specifies the expected maximum time between the port reception of a SMP and the transmission of the associated response.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..31  

ibSmaDataPortInfo 1.3.6.1.3.117.3.1.5
OBJECT IDENTIFIER    

ibSmaPortInfoTable 1.3.6.1.3.117.3.1.5.1
A table containing SMA PortInfo information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaPortInfoEntry

ibSmaPortInfoEntry 1.3.6.1.3.117.3.1.5.1.1
A conceptual row of the ibSmaPortInfoTable containing information about a particular data port and its attributes.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaPortInfoEntry  

ibSmaPortIndex 1.3.6.1.3.117.3.1.5.1.1.1
Index that identifies the InfiniBand data port.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPort  

ibSmaPortLinkWidthEnabled 1.3.6.1.3.117.3.1.5.1.1.2
Enabled link width, indicated as follows: 0: No State Change (NOP) 1: 1x 2: 4x 3: 1x or 4x 8: 12x 9: 1x or 12x 10: 4x or 12x 11: 1x, 4x or 12x 4 - 7, 12 - 254: Reserved (Ignored) 255: Set to LinkWidthSupported value.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oneX(1), fourX(2), oneXOr4X(3), twelveX(4), oneXOr12X(5), fourXOr12X(6), oneX4XOr12X(7), linkWidthSupported(8), other(9)  

ibSmaPortLinkWidthSupported 1.3.6.1.3.117.3.1.5.1.1.3
Supported link width for this port. This is indicated as follows by the SMA: 1: 1x 3: 1x or 4x 11: 1x, 4x or 12x 0, 2, 4-10, 12-255: Reserved.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oneX(1), oneXOr4X(2), oneX4XOr12X(3), other(4)  

ibSmaPortLinkWidthActive 1.3.6.1.3.117.3.1.5.1.1.4
Currently active link width on this port. This is indicated as follows by the SMA: 1: 1x 2: 4x 8: 12x 0, 3, 4-7, 9-255: Reserved.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oneX(1), fourX(2), twelveX(3), other(4)  

ibSmaPortLinkSpeedSupported 1.3.6.1.3.117.3.1.5.1.1.5
Supported link speed, indicated as follows: 1: 2.5Gbps 0, 2 - 15: reserved
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER twoPoint5Gbps(1), other(2)  

ibSmaPortLinkState 1.3.6.1.3.117.3.1.5.1.1.6
The state of the link on this port. 0: No state change 1: Down (includes failed links) 2: Initialize 3: Armed 4: Active 5-15: Reserved
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(1), init(2), armed(3), active(4), other(5)  

ibSmaPortPhysState 1.3.6.1.3.117.3.1.5.1.1.7
Physical Port State. Enumerated as: 0: No state change 1: Sleep 2: Polling 3: Disabled 4: PortConfigurationTraining 5: LinkUp 6: LinkErrorRecovery 7 - 15: Reserved
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sleep(1), polling(2), disabled(3), portConfigTraining(4), linkUp(5), linkErrorRecovery(6), other(7)  

ibSmaPortLinkDownDefaultState 1.3.6.1.3.117.3.1.5.1.1.8
LinkDownDefault-State 0: No state change 1: Sleep 2: Polling 3-15: Reserved
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sleep(1), polling(2), other(3)  

ibSmaPortLidMaskCount 1.3.6.1.3.117.3.1.5.1.1.9
LID Mask Control count for multipath support for CA and router ports.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..7  

ibSmaPortLinkSpeedActive 1.3.6.1.3.117.3.1.5.1.1.10
Currently active link speed, indicated as follows: 1: 2.5Gbps 0, 2 - 15: reserved.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER twoPoint5Gbps(1), other(2)  

ibSmaPortLinkSpeedEnabled 1.3.6.1.3.117.3.1.5.1.1.11
Enabled link speed, indicated as follows: 0: No State Change (NOP) 1: 2.5 Gbps 2 - 14: Reserved (Ignored) 15: Set to LinkSpeedSupported value.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER twoPoint5Gbps(1), linkSpeedSupported(2), other(3)  

ibSmaPortNeighborMtu 1.3.6.1.3.117.3.1.5.1.1.12
Active maximum MTU enabled on this port for transmit: 1: 256 bytes 2: 512 bytes 3: 1024 bytes 4: 2048 bytes 5: 4096 bytes 0, 6 - 15: reserved
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER mtu256(1), mtu512(2), mtu1024(3), mtu2048(4), mtu4096(5), other(6)  

ibSmaPortVirtLaneSupport 1.3.6.1.3.117.3.1.5.1.1.13
Virtual Lane configuration supported on this port. Indicated as follows by the SMA: 1: VL0 2: VL0, VL1 3: VL0 - VL3 4: VL0 - VL7 5: VL0 - VL14 0, 6 - 15: reserved.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vl0(1), vl0ToVl1(2), vl0ToVl3(3), vl0ToVl7(4), vl0ToVl14(5), other(6)  

ibSmaPortVlHighPriorityLimit 1.3.6.1.3.117.3.1.5.1.1.14
Limit of High Priority component of VL Arbitration Table. This object indicates the amount of high priority packets that can be transmitted without an opportunity to send a low priority packet. Specifically, the number of bytes that can be sent is this value times 4K bytes. A 255 value means the byte limit is unbounded and a value of 0 means that only a single packet from the high-priority table may be sent before an opportunity is given to the low-priority table.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

ibSmaPortVlArbHighCapacity 1.3.6.1.3.117.3.1.5.1.1.15
VL/Weight pairs supported on this port in the VLArbitration table (ibSmaHiPriVlArbTable) for high priority. Shall be 1 to 64 if more than one data VL is supported on this port, 0 otherwise.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..64  

ibSmaPortVlArbLowCapacity 1.3.6.1.3.117.3.1.5.1.1.16
VL/Weight pairs supported on this port in the VLArbitration table (ibSmaLoPriVlArbTable) for low priority. Shall be N to 64 if more than one data VL is supported on this port, 0 otherwise, N being the number of data VLs supported.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..64  

ibSmaPortMtuCapacity 1.3.6.1.3.117.3.1.5.1.1.17
Maximum MTU supported by this port. 1: 256 bytes 2: 512 bytes 3: 1024 bytes 4: 2048 bytes 5: 4096 bytes 0, 6 - 15: reserved
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER mtu256(1), mtu512(2), mtu1024(3), mtu2048(4), mtu4096(5), other(6)  

ibSmaPortVlStallCount 1.3.6.1.3.117.3.1.5.1.1.18
Specifies the number of sequential packets dropped that causes the port to enter the VLStalled state. The result of setting this value to 0 is undefined.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..7  

ibSmaPortHeadOfQueueLife 1.3.6.1.3.117.3.1.5.1.1.19
Sets the time a packet can live at the head of a Virtual Lane queue. This variable (HL) is used to compute the Head of the Queue Lifetime Limit (HLL). It is used in the formula when the HL value is between 0 and 19, inclusive. When HL is greater than 19, the HLL is to be interpreted as infinite.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..20  

ibSmaPortOperationalVls 1.3.6.1.3.117.3.1.5.1.1.20
Virtual Lanes operational on this port, indicated as follows: 0: No change 1: VL0 2: VL0 - VL1 3: VL0 - VL3 4: VL0 - VL7 5: VL0 - VL14 6 - 15: reserved
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vl0(1), vl0ToVl1(2), vl0ToVl3(3), vl0ToVl7(4), vl0ToVl14(5), other(6)  

ibSmaPortPartEnforceInbound 1.3.6.1.3.117.3.1.5.1.1.21
Indicates support of optional inbound partition enforcement. If true, partition enforcement on packets received on this port is enabled. If false partition enforcement on packets received from this port is disabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortPartEnforceOutbound 1.3.6.1.3.117.3.1.5.1.1.22
Indicates support of optional outbound partition enforcement. If true, partition enforcement on packets transmitted on this port is enabled. If false partition enforcement on packets transmitted from this port is disabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortFilterRawPktInbound 1.3.6.1.3.117.3.1.5.1.1.23
Indicates support of optional inbound raw packet enforcement. If true, raw packets arriving on this port are discarded. If false, raw enforcement on packets received from this port is disabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortFilterRawPktOutbound 1.3.6.1.3.117.3.1.5.1.1.24
Indicates support of optional outbound raw packet enforcement. If true, raw packets departing on this port are discarded. If false, raw enforcement on packets leaving from this port is disabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortLocalPhysErrorThreshold 1.3.6.1.3.117.3.1.5.1.1.25
Local Physical Error threshold value. When the count of marginal link errors exceeds this threshold, the local link integrity error shall be detected.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..15  

ibSmaPortOverrunErrorThreshold 1.3.6.1.3.117.3.1.5.1.1.26
Overrun error threshold value. When the count of buffer overruns over consecutive flow control update periods exceeds this threshold, the excessive buffer overrun error shall be detected.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..15  

ibSmaPKeyInfo 1.3.6.1.3.117.3.1.6
OBJECT IDENTIFIER    

ibSmaPKeyTable 1.3.6.1.3.117.3.1.6.1
This table contains SMA Partition Key information for this port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaPKeyEntry

ibSmaPKeyEntry 1.3.6.1.3.117.3.1.6.1.1
A conceptual row of the ibSmaPKeyTable containing information about the partition keys.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaPKeyEntry  

ibSmaPKeyIBAPortIndex 1.3.6.1.3.117.3.1.6.1.1.1
The IB data port index for the switch data ports. For switch management port 0 and for CAs and routers, the index value should be 255. This indicates that the entry is not referring to a valid switch data port.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPortAndInvalid  

ibSmaPKeyIndex 1.3.6.1.3.117.3.1.6.1.1.2
The entry Identifier for each Partition Key defined on a port. (The IB spec specifies 0..2047 blocks of 32 entries each for a total of 65,504 maximum entries, although the implemented limit is defined by PartitionCap for CAs, routers, and switch port 0, and by PartitionEnforcementCap for the switch data ports).
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..65504  

ibSmaPKeyMembership 1.3.6.1.3.117.3.1.6.1.1.3
If the P_Key type is limited(2), the switch may accept a packet with a matching full P_Key, but may not accept a packet with a matching limited key. If the P_Key type is full(3), the switch can accept packets with either a full or limited P_Key. If the P_Key type is none(1), there is no associated Key Base value.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), limited(2), full(3)  

ibSmaPKeyBase 1.3.6.1.3.117.3.1.6.1.1.4
15-bit base value of the P_Key that the switch will use to check against incoming packets.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65527  

ibSmaSlToVlMapInfo 1.3.6.1.3.117.3.1.7
OBJECT IDENTIFIER    

ibSmaSL2VLMapTable 1.3.6.1.3.117.3.1.7.1
This table provides the virtual lane value for the output port/input port/service level mapping. Each output port contains a VL mapping for the next hop based on the input port the packet arrived on and its SL value.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaSL2VLMapEntry

ibSmaSL2VLMapEntry 1.3.6.1.3.117.3.1.7.1.1
Column definitions for the VL from output/input/SL entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaSL2VLMapEntry  

ibSmaIBAOutPortIndex 1.3.6.1.3.117.3.1.7.1.1.1
The egress port index for the service level mapping. A value of 255 indicates the switch management port 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPortAndInvalid  

ibSmaIBAInPortIndex 1.3.6.1.3.117.3.1.7.1.1.2
The ingress port index for the service level mapping. A value of 255 indicates the switch management port 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPortAndInvalid  

ibSmaServiceLevelIndex 1.3.6.1.3.117.3.1.7.1.1.3
The Service Level value index for this mapping.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..15  

ibSmaVirtualLane 1.3.6.1.3.117.3.1.7.1.1.4
The outgoing packet's Virtual Lane value for this Service Level Mapping.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..15  

ibSmaVLArbitInfo 1.3.6.1.3.117.3.1.8
OBJECT IDENTIFIER    

ibSmaHiPriVlArbTable 1.3.6.1.3.117.3.1.8.1
This table provides visibility into the High Priority Arbitration process for configuring VL/Weight pairs for the IB data ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaHiPriVlArbEntry

ibSmaHiPriVlArbEntry 1.3.6.1.3.117.3.1.8.1.1
Column definitions for High Priority Arbitration Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaHiPriVlArbEntry  

ibSmaHiPriIBAPortIndex 1.3.6.1.3.117.3.1.8.1.1.1
The index for the configured IBA port.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPort  

ibSmaHiPriNIndex 1.3.6.1.3.117.3.1.8.1.1.2
The High Priority list index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..64  

ibSmaHiPriVirtLane 1.3.6.1.3.117.3.1.8.1.1.3
The virtual lane this entry applies to.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..14  

ibSmaHiPriWeight 1.3.6.1.3.117.3.1.8.1.1.4
Number of 64-byte units that may be transmitted from this VL when its turn in the arbitration process occurs. A weight of 0 indicates that the entry should be skipped.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

ibSmaLowPriVlArbTable 1.3.6.1.3.117.3.1.8.2
This table provides visibility into the Low Priority Arbitration process.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaLowPriVlArbEntry

ibSmaLowPriVlArbEntry 1.3.6.1.3.117.3.1.8.2.1
Column definitions for Low Priority Arbitration Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaLowPriVlArbEntry  

ibSmaLowPriIBAPortIndex 1.3.6.1.3.117.3.1.8.2.1.1
The index for the configured IB data port.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPort  

ibSmaLowPriNIndex 1.3.6.1.3.117.3.1.8.2.1.2
The Low Priority list index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..64  

ibSmaLowPriVirtLane 1.3.6.1.3.117.3.1.8.2.1.3
The Virtual Lane this entry applies to.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..14  

ibSmaLowPriWeight 1.3.6.1.3.117.3.1.8.2.1.4
Number of 64-byte units that may be transmitted from this VL when its turn in the arbitration process occurs. A weight of 0 indicates that the entry should be skipped.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

ibSmaLFTInfo 1.3.6.1.3.117.3.1.9
OBJECT IDENTIFIER    

ibSmaLinForTable 1.3.6.1.3.117.3.1.9.1
A table containing information about the Linear Forwarding Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaLinForEntry

ibSmaLinForEntry 1.3.6.1.3.117.3.1.9.1.1
Current unicast forwarding Table entry configured by the Subnet Manager based on destination LID.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaLinForEntry  

ibSmaLinDestDLIDIndex 1.3.6.1.3.117.3.1.9.1.1.1
Index that identifies Destination Local Identifier (DLID) that the forwarding entry refers to in the Linear Forwarding Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbUnicastLid  

ibSmaLinForwEgressPort 1.3.6.1.3.117.3.1.9.1.1.2
The port to which packets with the LID corresponding to this entry are to be forwarded.
Status: current Access: read-only
OBJECT-TYPE    
  IbDataPortAndInvalid  

ibSmaRFTInfo 1.3.6.1.3.117.3.1.10
OBJECT IDENTIFIER    

ibSmaRandomForwardingTable 1.3.6.1.3.117.3.1.10.1
A table containing SMA Random Forwarding information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaRandomForwardingEntry

ibSmaRandomForwardingEntry 1.3.6.1.3.117.3.1.10.1.1
A conceptual row of the ibSmaRandomForwardingTable containing information about the Random Forwarding Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaRandomForwardingEntry  

ibSmaRandomForwardingPortIndex 1.3.6.1.3.117.3.1.10.1.1.1
The port index value.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPort  

ibSmaRandomDestLID 1.3.6.1.3.117.3.1.10.1.1.2
Identifies Destination Local Identifier (DLID) that the forwarding entry refers to.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..49152  

ibSmaRandomForwEgressPort 1.3.6.1.3.117.3.1.10.1.1.3
The port to which packets with the LID corresponding to this entry are to be forwarded.
Status: current Access: read-only
OBJECT-TYPE    
  IbDataPort  

ibSmaRandomLMC 1.3.6.1.3.117.3.1.10.1.1.4
The LID Mask Control (LMC) of this LID. The LMC specifies the number of Path Bits in the Local Identifier.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..7  

ibSmaRandomIsValid 1.3.6.1.3.117.3.1.10.1.1.5
If true, this LID/Port pair is valid. Note that when the SMA sets this parameter to false(2), entries can be removed.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaMFTInfo 1.3.6.1.3.117.3.1.11
OBJECT IDENTIFIER    

ibSmaMulForTable 1.3.6.1.3.117.3.1.11.1
A table containing information about the Multicast Forwarding Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaMulForEntry

ibSmaMulForEntry 1.3.6.1.3.117.3.1.11.1.1
Current multicast forwarding table entry as configured by the Subnet Manager based on destination LID.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaMulForEntry  

ibSmaMulDestDLIDIndex 1.3.6.1.3.117.3.1.11.1.1.1
Identifies Destination Local Identifier (DLID) that the forwarding entry refers to in the Multicast Forwarding Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbMulticastLid  

ibSmaMulForwMask 1.3.6.1.3.117.3.1.11.1.1.2
A 256-bit mask that represents the port list. An incoming packet with this LID table entry will be forwarded to all ports for which the bit in the port mask is set to 1.
Status: current Access: read-only
OBJECT-TYPE    
  IbSmPortList  

ibSmaSMInfo 1.3.6.1.3.117.3.1.12
OBJECT IDENTIFIER    

ibSmaSubMgrInfo 1.3.6.1.3.117.3.1.12.1
OBJECT IDENTIFIER    

ibSmaSmInfoTable 1.3.6.1.3.117.3.1.12.1.1
A table containing SMA Subnet Manager information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaSmInfoEntry

ibSmaSmInfoEntry 1.3.6.1.3.117.3.1.12.1.1.1
A conceptual row of the ibSmaSmInfoTable containing information about the Subnet Manager Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaSmInfoEntry  

ibSmaSmInfoPortIndex 1.3.6.1.3.117.3.1.12.1.1.1.1
The port index value.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPort  

ibSmaSmGuid 1.3.6.1.3.117.3.1.12.1.1.1.2
The Port GUID of the port where the SM resides.
Status: current Access: read-only
OBJECT-TYPE    
  IbGuid  

ibSmaSmSmKey 1.3.6.1.3.117.3.1.12.1.1.1.3
Key for this SM. This is shown as zeroes unless the requesting SM is proven to be the master, or the requester is otherwise authenticated.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

ibSmaSmSmpCount 1.3.6.1.3.117.3.1.12.1.1.1.4
Counter that increments each time the SM issues an SMP or performs other management activities. This counter is used as a heartbeat indicator by standby SMs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ibSmaSmPriority 1.3.6.1.3.117.3.1.12.1.1.1.5
Administratively assigned priority for this SM. This can be reset by master SM. 0 is the lowest priority. An out-of-band mechanism shall be provided to set this value. The default value SHALL be 0.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..15  

ibSmaSmState 1.3.6.1.3.117.3.1.12.1.1.1.6
Enumerated value indicating this SM's state. The InfiniBand enumeration values are: 0 - not active 1 - discovering 2 - standby 3 - master 4-15 - reserved. Note: a value of reserved returns unknown(5).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notActive(1), discovering(2), standby(3), master(4), unknown(5)  

ibSmaVendDiagInfo 1.3.6.1.3.117.3.1.13
OBJECT IDENTIFIER    

ibSmaVendDiagInfoTable 1.3.6.1.3.117.3.1.13.1
A table containing SMA Vendor Diagnostic Info information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaVendDiagInfoEntry

ibSmaVendDiagInfoEntry 1.3.6.1.3.117.3.1.13.1.1
A conceptual row of the ibSmaVendDiagInfoTable containing information about a particular data port's diagnostic status.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaVendDiagInfoEntry  

ibSmaVendDiagPortIndex 1.3.6.1.3.117.3.1.13.1.1.1
Index that identifies the port for the diagnostics. If the index value is 255, information about the management port is returned.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPortAndInvalid  

ibSmaPortGenericDiagCode 1.3.6.1.3.117.3.1.13.1.1.2
The generic portion of the Port Info Diagnostic code.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER portReady(1), performingSelfTest(2), initializing(3), softError(4), hardError(5), other(6)  

ibSmaPortVendorDiagCode 1.3.6.1.3.117.3.1.13.1.1.3
The vendor specific portion of the Port Info Diagnostic code.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2047  

ibSmaPortVendorDiagIndexFwd 1.3.6.1.3.117.3.1.13.1.1.4
Flag to control ibSmaPortVendorDiagData data buffer. If this boolean is true(1), the data buffer contains meaningful vendor-supplied additional diagnostic information. If this object is false(2), the buffer is empty.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ibSmaPortVendorDiagData 1.3.6.1.3.117.3.1.13.1.1.5
Data buffer that can contain additional vendor-specific diagnostic information. The ibSmaPortVendorDiagIndexFwd flag controls whether this object contains meaningful data. Note: in IB, this buffer comprises n number of 62 byte buffers. This object defines a buffer that can hold up to 2 of these IB chained buffers.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(124)  

ibSmaLedInfo 1.3.6.1.3.117.3.1.14
OBJECT IDENTIFIER    

ibSmaLedInfoTable 1.3.6.1.3.117.3.1.14.1
A table containing SMA LED Info information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IbSmaLedInfoEntry

ibSmaLedInfoEntry 1.3.6.1.3.117.3.1.14.1.1
A conceptual row of the ibSmaLedInfoTable containing information about a particular data port's LED status.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbSmaLedInfoEntry  

ibSmaLedIndex 1.3.6.1.3.117.3.1.14.1.1.1
Index that identifies the IB data port with its LED.
Status: current Access: not-accessible
OBJECT-TYPE    
  IbDataPort  

ibSmaLedState 1.3.6.1.3.117.3.1.14.1.1.2
State of the LED.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), on(2), off(3)  

ibSmaNotificationPrefix 1.3.6.1.3.117.3.2.0
OBJECT IDENTIFIER    

ibSmaPortLinkStateChange 1.3.6.1.3.117.3.2.0.1
This notification translates InfiniBand SMA Trap 128: Link State of at least one port of switch at has changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaLinkIntegrityThresReached 1.3.6.1.3.117.3.2.0.2
This notification translates InfiniBand SMA Trap 129: Local Link Integrity threshold reached at .
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaExcessBuffOverrunThres 1.3.6.1.3.117.3.2.0.3
This notification translates InfiniBand SMA Trap 130: Excessive Buffer Overrun threshold reached at .
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaFlowCntrlUpdateTimerExpire 1.3.6.1.3.117.3.2.0.4
This notification translates InfiniBand SMA Trap 131: Switch Flow Control Update watchdog timer expired at .
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaCapabilityMaskModified 1.3.6.1.3.117.3.2.0.5
This notification translates InfiniBand SMA Trap 144: The capability mask at has been modified to .
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaSysImageGuidModified 1.3.6.1.3.117.3.2.0.6
This notification translates InfiniBand SMA Trap 145: The System Image GUID at has been modified to .
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaBadManagementKey 1.3.6.1.3.117.3.2.0.7
This notification translates InfiniBand SMA Trap 256: Bad M_Key, from attempted with and .
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaBadPartitionKey 1.3.6.1.3.117.3.2.0.8
This notification translates InfiniBand SMA Trap 257: Bad P_Key, from // to // on .
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaBadQueueKey 1.3.6.1.3.117.3.2.0.9
This notification translates InfiniBand SMA Trap 258: Bad Q_Key, from // to // on .
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaBadPKeyAtSwitchPort 1.3.6.1.3.117.3.2.0.10
This notification translates InfiniBand SMA Trap 259: Bad P_Key, from // to // on at switch external port , where the validity of the fields is indicated by .
Status: current Access: read-only
NOTIFICATION-TYPE    

ibSmaCompliances 1.3.6.1.3.117.3.3.1
OBJECT IDENTIFIER    

ibSmaGroups 1.3.6.1.3.117.3.3.2
OBJECT IDENTIFIER    

ibSmaBasicNodeCompliance 1.3.6.1.3.117.3.3.1.1
The basic node implementation requirements for agents that support the IPOIB SMA MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

ibSmaFullSwitchCompliance 1.3.6.1.3.117.3.3.1.2
The full node implementation requirements for agents that support the IPOIB SMA MIB for InfiniBand switches.
Status: current Access: read-only
MODULE-COMPLIANCE    

ibSmaFullRouterCACompliance 1.3.6.1.3.117.3.3.1.3
The full node implementation requirements for agents that support the IPOIB SMA MIB for InfiniBand CAs and routers.
Status: current Access: read-only
MODULE-COMPLIANCE    

ibSmaNodeGroup 1.3.6.1.3.117.3.3.2.1
The ibSmaNodeGroup defines the MIB objects that describe this InfiniBand subnet node.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaSwitchGroup 1.3.6.1.3.117.3.3.2.2
The ibSmaSwitchGroup defines the MIB objects that describe this InfiniBand switch.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaGuidGroup 1.3.6.1.3.117.3.3.2.3
The ibSmaGuidGroup defines the MIB object that describes the GUIDs associated with this node.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaMgmtPortGroup 1.3.6.1.3.117.3.3.2.4
The ibSmaMgmtPortGroup defines the MIB objects that describe the management port.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaDataPortGroup 1.3.6.1.3.117.3.3.2.5
The ibSmaDataPortGroup defines MIB objects for IB data ports.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaPKeyGroup 1.3.6.1.3.117.3.3.2.6
The ibSmaPKeyGroup defines the MIB objects that describe the Partition Keys.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaSlToVlMapGroup 1.3.6.1.3.117.3.3.2.7
The ibSmaSlToVlMapGroup defines the MIB objects that describe the Service Level to Virtual Lane mapping.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaVLArbitGroup 1.3.6.1.3.117.3.3.2.8
The ibSmaVLArbitGroup defines the MIB objects that describe the Virtual Lane High and Low Arbitrations.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaLFTGroup 1.3.6.1.3.117.3.3.2.9
The ibSmaLFTGroup defines the MIB objects that describe the Linear Forwarding Table.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaRFTGroup 1.3.6.1.3.117.3.3.2.10
The ibSmaRFTGroup defines the MIB objects that describe the Random Forwarding Table.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaMFTGroup 1.3.6.1.3.117.3.3.2.11
The ibSmaMFTGroup defines the MIB objects that describe the Multicast Forwarding Table.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaSMGroup 1.3.6.1.3.117.3.3.2.12
The ibSmaSMGroup defines the MIB objects that describe the Subnet Manager Information Table.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaVendDiagGroup 1.3.6.1.3.117.3.3.2.13
The ibSmaVendDiagGroup defines the MIB objects that describe the vendor diagnostics table.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaLedGroup 1.3.6.1.3.117.3.3.2.14
The ibSmaSMGroup defines the MIB objects that describe the LED table.
Status: current Access: read-only
OBJECT-GROUP    

ibSmaNotificationsGroup 1.3.6.1.3.117.3.3.2.15
The notifications that an IPOIB SNMP agent transmits on the behalf of the SMA Trap message implementation.
Status: current Access: read-only
NOTIFICATION-GROUP