HUAWEI-TAD-MIB

File: HUAWEI-TAD-MIB.mib (15909 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
HUAWEI-MIB IF-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Counter32 OBJECT-IDENTITY TEXTUAL-CONVENTION
DisplayString DateAndTime OBJECT-GROUP
MODULE-COMPLIANCE hwDatacomm ifIndex
InterfaceIndex

Defined Types

HWEnableValue  
A simple status value for the object.
TEXTUAL-CONVENTION    
  INTEGER enable(1), disable(2)  

HwTADInterfaceEntry  
SEQUENCE    
  hwTADInterfaceIndex InterfaceIndex
  hwTADFilterEnable HWEnableValue
  hwTADFilterExpireTime Integer32
  hwTADDampingEnable HWEnableValue
  hwTADSuppress Integer32
  hwTADCeiling Integer32
  hwTADReuse Integer32
  hwTADDecayOk Integer32
  hwTADDecayNg Integer32
  hwTADResetStatistics INTEGER
  hwTADResetTime DateAndTime
  hwTADB3tcaThreshold Integer32
  hwTADSdbereThreshold Integer32
  hwTADSfbereThreshold Integer32
  hwTADB1tcaThreshold Integer32
  hwTADB2tcaThreshold Integer32
  hwTADBip2tcaThreshold Integer32

HwTADAlarmEntry  
SEQUENCE    
  hwTADAlarmIfIndex InterfaceIndex
  hwTADAlarmType INTEGER
  hwTADAlarmIfDown HWEnableValue
  hwTADAlarmLog HWEnableValue
  hwTADAlarmStatus INTEGER
  hwTADAlarmInFilter INTEGER
  hwTADAlarmFigure DisplayString
  hwTADAlarmInSuppress INTEGER
  hwTADAlarmFlappingCount Counter32
  hwTADAlarmSuppressCount Counter32

Defined Values

hwTAD 1.3.6.1.4.1.2011.5.25.128
The Custom damping MIB module is defined to manage the configuration under system or interface view.
MODULE-IDENTITY    

hwTADObjects 1.3.6.1.4.1.2011.5.25.128.1
OBJECT IDENTIFIER    

hwTADInterfaceTable 1.3.6.1.4.1.2011.5.25.128.1.1
Transmission alarm damping interface configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwTADInterfaceEntry

hwTADInterfaceEntry 1.3.6.1.4.1.2011.5.25.128.1.1.1
The entry of a SDH or SONET interface with damping function enabled.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwTADInterfaceEntry  

hwTADInterfaceIndex 1.3.6.1.4.1.2011.5.25.128.1.1.1.1
Index number of the interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

hwTADFilterEnable 1.3.6.1.4.1.2011.5.25.128.1.1.1.2
Whether filter function is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  HWEnableValue  

hwTADFilterExpireTime 1.3.6.1.4.1.2011.5.25.128.1.1.1.3
How long the alarm will be postponed to process. Unit: millisecond.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 20..10000  

hwTADDampingEnable 1.3.6.1.4.1.2011.5.25.128.1.1.1.4
Whether damping function is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  HWEnableValue  

hwTADSuppress 1.3.6.1.4.1.2011.5.25.128.1.1.1.5
The suppressing value. When figure-of-merit of alarm exceeds this value, this alarm will be damped.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 2..19999  

hwTADCeiling 1.3.6.1.4.1.2011.5.25.128.1.1.1.6
The ceiling value. Figure-of-merit can't exceed this value. The ceiling value must be larger than suppressing value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1001..20000  

hwTADReuse 1.3.6.1.4.1.2011.5.25.128.1.1.1.7
The reusing value. When figure-of-merit becomes lower than this value. The alarm will be reused (exit from suppressing status). The reusing value must be less than suppressing value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..19998  

hwTADDecayOk 1.3.6.1.4.1.2011.5.25.128.1.1.1.8
The half decay time when alarm status is down. Unit: millisecond.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 500..10000  

hwTADDecayNg 1.3.6.1.4.1.2011.5.25.128.1.1.1.9
The half decay time when alarm status is up. Unit: millisecond.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 500..10000  

hwTADResetStatistics 1.3.6.1.4.1.2011.5.25.128.1.1.1.10
Whether to reset alarm statistics. 1 means resetting statistics once.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), unreset(2)  

hwTADResetTime 1.3.6.1.4.1.2011.5.25.128.1.1.1.11
Last reset time.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

hwTADB3tcaThreshold 1.3.6.1.4.1.2011.5.25.128.1.1.1.12
B3tca threshold in form of 10e-n.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

hwTADSdbereThreshold 1.3.6.1.4.1.2011.5.25.128.1.1.1.13
Sdbere threshold in form of 10e-n.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

hwTADSfbereThreshold 1.3.6.1.4.1.2011.5.25.128.1.1.1.14
Sfbere threshold in form of 10e-n.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

hwTADB1tcaThreshold 1.3.6.1.4.1.2011.5.25.128.1.1.1.15
B1tca threshold in form of 10e-n.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

hwTADB2tcaThreshold 1.3.6.1.4.1.2011.5.25.128.1.1.1.16
B2tca threshold in form of 10e-n.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

hwTADBip2tcaThreshold 1.3.6.1.4.1.2011.5.25.128.1.1.1.17
Bip2tca threshold in form of 10e-n.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

hwTADAlarmTable 1.3.6.1.4.1.2011.5.25.128.1.2
Transmission alarm damping alarm configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwTADAlarmEntry

hwTADAlarmEntry 1.3.6.1.4.1.2011.5.25.128.1.2.1
The entry of an alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwTADAlarmEntry  

hwTADAlarmIfIndex 1.3.6.1.4.1.2011.5.25.128.1.2.1.1
Index number of the interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

hwTADAlarmType 1.3.6.1.4.1.2011.5.25.128.1.2.1.2
Index number of the alarm. The range is from 1 to 39, corresponding to: auais, b3tca, lais, lof, lom, lop, los, lrdi, lrei, oof, pais, prdi, prei, pplm, rdool, rrool, sdbere, sfbere, trool, puneq, lcd, wlnk, oduais, odulck, oduoci, otuais, otulom, otusdber, otusfber, pmbdi, pmtim, rlof, rlos, roof, smbdi, smiae, smtim, b1tca, b2tca, prefectca.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER auais(1), b3tca(2), lais(3), lof(4), lom(5), lop(6), los(7), lrdi(8), lrei(9), oof(10), pais(11), prdi(12), prei(13), pplm(14), rdool(15), rrool(16), sdbere(17), sfbere(18), trool(19), puneq(20), lcd(21), wlnk(22), oduais(23), odulck(24), oduoci(25), otuais(26), otuom(27), otusdber(28), otusfber(29), pmbdi(30), pmtim(31), rlof(32), rlos(33), roof(34), smbdi(35), smiae(36), smtim(37), b1tca(38), b2tca(39), prefectca(40)  

hwTADAlarmIfDown 1.3.6.1.4.1.2011.5.25.128.1.2.1.3
Whether this alarm leads to interface down. In default lais, lof and los are enabled to lead interface down.
Status: current Access: read-write
OBJECT-TYPE    
  HWEnableValue  

hwTADAlarmLog 1.3.6.1.4.1.2011.5.25.128.1.2.1.4
Whether this alarm will be logged. In default all alarm types won't be logged.
Status: current Access: read-write
OBJECT-TYPE    
  HWEnableValue  

hwTADAlarmStatus 1.3.6.1.4.1.2011.5.25.128.1.2.1.5
The status of the alarm. 1 means alarm is up, 2 means alarm is down.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

hwTADAlarmInFilter 1.3.6.1.4.1.2011.5.25.128.1.2.1.6
Whether this alarm is in filtering status. 1 means alarm is in filtering status, 2 means alarm isn't in filtering status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER in(1), out(2)  

hwTADAlarmFigure 1.3.6.1.4.1.2011.5.25.128.1.2.1.7
This figure is used to evaluate the stability of the alarm. Large value means un-stability.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

hwTADAlarmInSuppress 1.3.6.1.4.1.2011.5.25.128.1.2.1.8
Whether this alarm is in suppressing status. 1 means alarm is in suppressing status, 2 means alarm isn't in suppressing status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER suppressed(1), unsuppressed(2)  

hwTADAlarmFlappingCount 1.3.6.1.4.1.2011.5.25.128.1.2.1.9
How many times alarm's status changed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwTADAlarmSuppressCount 1.3.6.1.4.1.2011.5.25.128.1.2.1.10
How many times alarm is suppressed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwTADConformance 1.3.6.1.4.1.2011.5.25.128.2
OBJECT IDENTIFIER    

hwTADGroups 1.3.6.1.4.1.2011.5.25.128.2.1
OBJECT IDENTIFIER    

hwTADInterfaceGroup 1.3.6.1.4.1.2011.5.25.128.2.1.1
A collection of objects providing device level control and status information for the interface.
Status: current Access: read-only
OBJECT-GROUP    

hwTADAlarmGroup 1.3.6.1.4.1.2011.5.25.128.2.1.2
A collection of objects providing device level control and status information for the alarm.
Status: current Access: read-only
OBJECT-GROUP    

hwTADCompliances 1.3.6.1.4.1.2011.5.25.128.2.2
OBJECT IDENTIFIER    

hwTADCompliance 1.3.6.1.4.1.2011.5.25.128.2.2.1
The core compliance statement for all TAD implementations.
Status: current Access: read-only
MODULE-COMPLIANCE