HUAWEI-ND-MIB

File: HUAWEI-ND-MIB.mib (11996 bytes)

Imported modules

HUAWEI-MIB SNMPv2-SMI SNMPv2-TC
SNMPv2-CONF IF-MIB ENTITY-MIB

Imported symbols

hwDatacomm OBJECT-TYPE MODULE-IDENTITY
IpAddress Counter32 Integer32
Unsigned32 NOTIFICATION-TYPE PhysAddress
DisplayString RowStatus NOTIFICATION-GROUP
OBJECT-GROUP MODULE-COMPLIANCE ifIndex
ifName InterfaceIndex InterfaceIndexOrZero
ifAdminStatus ifOperStatus ifDescr
PhysicalIndex entPhysicalIndex entPhysicalName

Defined Types

HwNDStatisticsPerSlotEntry  
SEQUENCE    
  hwNDSlotPhysicalIndex Unsigned32
  hwNDSlotThresholdExceedValue Unsigned32
  hwNDSlotThresholdResumeValue Unsigned32
  hwNDSlotDynamicNumber Unsigned32
  hwNDSlotStaticNumber Unsigned32
  hwNDSlotTotalNumber Unsigned32

HwNDStatisticsPerIfEntry  
SEQUENCE    
  hwNDIntfIndex Unsigned32
  hwNDIntfThresholdExceedValue Unsigned32
  hwNDIntfThresholdResumeValue Unsigned32
  hwNDIntfDynamicNumber Unsigned32
  hwNDIntfStaticNumber Unsigned32
  hwNDIntfTotalNumber Unsigned32

Defined Values

hwNDMIB 1.3.6.1.4.1.2011.5.25.332
Please provide the descritpion.
MODULE-IDENTITY    

hwNDObjects 1.3.6.1.4.1.2011.5.25.332.1
OBJECT IDENTIFIER    

hwNDStatisticsPerSlotTable 1.3.6.1.4.1.2011.5.25.332.1.1
This object indicates the threshold of the alarm generated in slot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwNDStatisticsPerSlotEntry

hwNDStatisticsPerSlotEntry 1.3.6.1.4.1.2011.5.25.332.1.1.1
This object indicates the threshold of the alarm generated in slot.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwNDStatisticsPerSlotEntry  

hwNDSlotPhysicalIndex 1.3.6.1.4.1.2011.5.25.332.1.1.1.1
The slot of alarm generated.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967294  

hwNDSlotThresholdExceedValue 1.3.6.1.4.1.2011.5.25.332.1.1.1.2
This object indicates an ND entry alarm threshold on a board. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is greater than or equal to the alarm threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..100  

hwNDSlotThresholdResumeValue 1.3.6.1.4.1.2011.5.25.332.1.1.1.3
This object indicates an ND entry clear alarm threshold on a board. An ND entry clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is less than or equal to the clear alarm threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..100  

hwNDSlotDynamicNumber 1.3.6.1.4.1.2011.5.25.332.1.1.1.4
Current dynamic ND entries in slot.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967294  

hwNDSlotStaticNumber 1.3.6.1.4.1.2011.5.25.332.1.1.1.5
Current static ND entries in slot.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967294  

hwNDSlotTotalNumber 1.3.6.1.4.1.2011.5.25.332.1.1.1.6
Maximum ND entries number for slot.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967294  

hwNDStatisticsPerIfTable 1.3.6.1.4.1.2011.5.25.332.1.2
This object indicates the threshold of the alarm generated in interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwNDStatisticsPerIfEntry

hwNDStatisticsPerIfEntry 1.3.6.1.4.1.2011.5.25.332.1.2.1
This object indicates the threshold of the alarm generated in interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwNDStatisticsPerIfEntry  

hwNDIntfIndex 1.3.6.1.4.1.2011.5.25.332.1.2.1.1
The interface of alarm generated.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967294  

hwNDIntfThresholdExceedValue 1.3.6.1.4.1.2011.5.25.332.1.2.1.2
This object indicates an ND entry alarm threshold on an interface. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is greater than or equal to the alarm threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..100  

hwNDIntfThresholdResumeValue 1.3.6.1.4.1.2011.5.25.332.1.2.1.3
This object indicates an ND entry clear alarm threshold on an interface. An ND entry clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is less than or equal to the clear alarm threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..100  

hwNDIntfDynamicNumber 1.3.6.1.4.1.2011.5.25.332.1.2.1.4
Current dynamic ND entries in interface.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967294  

hwNDIntfStaticNumber 1.3.6.1.4.1.2011.5.25.332.1.2.1.5
Current static ND entries in interface.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967294  

hwNDIntfTotalNumber 1.3.6.1.4.1.2011.5.25.332.1.2.1.6
Maximum ND entries number for interface.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967294  

hwNDNotifications 1.3.6.1.4.1.2011.5.25.332.2
OBJECT IDENTIFIER    

hwSlotNDThresholdExceedAlarm 1.3.6.1.4.1.2011.5.25.332.2.1
This object indicates that an alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is greater than or equal to the 80% threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

hwSlotNDThresholdResumeAlarm 1.3.6.1.4.1.2011.5.25.332.2.2
This object indicates that a clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is less than or equal to the 70% threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

hwInterfaceNDThresholdExceedAlarm 1.3.6.1.4.1.2011.5.25.332.2.3
This object indicates that an alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is greater than or equal to the 80% threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

hwInterfaceNDThresholdResumeAlarm 1.3.6.1.4.1.2011.5.25.332.2.4
This object indicates that a clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is less than or equal to the 70% threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

hwNDConformance 1.3.6.1.4.1.2011.5.25.332.3
OBJECT IDENTIFIER    

hwNDGroups 1.3.6.1.4.1.2011.5.25.332.3.1
OBJECT IDENTIFIER    

hwNDCompliances 1.3.6.1.4.1.2011.5.25.332.3.2
OBJECT IDENTIFIER    

hwNDSlotGroup 1.3.6.1.4.1.2011.5.25.332.3.1.1
A collection of objects for ND threshold alarm in interface.
Status: current Access: read-only
OBJECT-GROUP    

hwNDIntfGroup 1.3.6.1.4.1.2011.5.25.332.3.1.2
A collection of objects for ND threshold alarm in slot.
Status: current Access: read-only
OBJECT-GROUP    

hwNDNotificationsGroup 1.3.6.1.4.1.2011.5.25.332.3.1.3
notification Group.
Status: current Access: read-only
NOTIFICATION-GROUP    

hwNDCompliance 1.3.6.1.4.1.2011.5.25.332.3.2.1
The compliance statement for ND thre.
Status: current Access: read-only
MODULE-COMPLIANCE