HUAWEI-MSTP-MIB

File: HUAWEI-MSTP-MIB.mib (165421 bytes)

Imported modules

BRIDGE-MIB HUAWEI-MIB SNMPv2-CONF
SNMPv2-SMI SNMPv2-TC IF-MIB
P-BRIDGE-MIB

Imported symbols

BridgeId hwDatacomm OBJECT-GROUP
MODULE-COMPLIANCE NOTIFICATION-GROUP Integer32
Counter32 OBJECT-TYPE MODULE-IDENTITY
OBJECT-IDENTITY NOTIFICATION-TYPE RowStatus
TEXTUAL-CONVENTION InterfaceIndex ifIndex
ifName EnabledStatus

Defined Types

HwMSTPEnabledStatus  
A simple status value for the object.
TEXTUAL-CONVENTION    
  INTEGER enabled(1), disabled(2)  

HwMstpVIDAllocationEntry  
SEQUENCE    
  hwMstpVID Integer32
  hwMstpAdminMstID Integer32
  hwMstpOperMstID Integer32

HwMstpInstanceEntry  
SEQUENCE    
  hwMstpInstanceID Integer32
  hwMstpiBridgeID BridgeId
  hwMstpiBridgePriority Integer32
  hwMstpiDesignedRoot BridgeId
  hwMstpiRootPathCost Integer32
  hwMstpiRootPort Integer32
  hwMstpiRootType INTEGER
  hwMstpiRemainingHops Integer32
  hwMstpiAdminMappedVlanListLow OCTET STRING
  hwMstpiAdminMappedVlanListHigh OCTET STRING
  hwMstpiOperMappedVlanListLow OCTET STRING
  hwMstpiOperMappedVlanListHigh OCTET STRING
  hwMstpiRowStatus RowStatus

HwMstpPortEntry  
SEQUENCE    
  hwMstpiPortIndex Integer32
  hwMstpiState INTEGER
  hwMstpiPortPriority Integer32
  hwMstpiPathCost Integer32
  hwMstpiDesignatedRoot BridgeId
  hwMstpiDesignatedCost Integer32
  hwMstpiDesignatedBridge BridgeId
  hwMstpiDesignatedPort OCTET STRING
  hwMstpiStpPortEdgeport INTEGER
  hwMstpiStpPortPointToPoint INTEGER
  hwMstpiStpMcheck INTEGER
  hwMstpiStpTransLimit Integer32
  hwMstpiStpRXStpBPDU Counter32
  hwMstpiStpTXStpBPDU Counter32
  hwMstpiStpRXTCNBPDU Counter32
  hwMstpiStpTXTCNBPDU Counter32
  hwMstpiStpRXRSTPBPDU Counter32
  hwMstpiStpTXRSTPBPDU Counter32
  hwMstpiStpRXMSTPBPDU Counter32
  hwMstpiStpTXMSTPBPDU Counter32
  hwMstpiStpClearStatistics INTEGER
  hwMstpiStpDefaultPortCost INTEGER
  hwMstpiStpStatus HwMSTPEnabledStatus
  hwMstpiPortRootGuard HwMSTPEnabledStatus
  hwMstpiPortLoopGuard HwMSTPEnabledStatus
  hwMstpPortCompliance INTEGER
  hwMstpConfigDigestSnooping HwMSTPEnabledStatus
  hwMstpNoAgreementCheck HwMSTPEnabledStatus
  hwMstpPortTCNotify HwMSTPEnabledStatus
  hwMstpiStpPortBpduFilter INTEGER
  hwMstpiPortRole INTEGER

HwMstpAccessoryEntry  
SEQUENCE    
  hwMstpAccessoryIndex Integer32
  hwMstpBackupReplyAgreement INTEGER
  hwMstpStpNoAgreementCheck INTEGER

HwMstpProEntry  
SEQUENCE    
  hwMstpProID Integer32
  hwMstpProStpState HwMSTPEnabledStatus
  hwMstpProPriority Integer32
  hwMstpProRootType INTEGER
  hwMstpProForceVersion INTEGER
  hwMstpProBpduGuard HwMSTPEnabledStatus
  hwMstpProDiameter Integer32
  hwMstpProConvergeMode INTEGER
  hwMstpProMaxHops Integer32
  hwMstpProMCheck INTEGER
  hwMstpProPathCostStandard INTEGER
  hwMstpProHelloTime Integer32
  hwMstpProFwdDelay Integer32
  hwMstpProMaxAge Integer32
  hwMstpProTimerFactor Integer32
  hwMstpProTCNotify OCTET STRING
  hwMstpProNoLinkSharePortList OCTET STRING
  hwMstpProLinkSharePortList OCTET STRING
  hwMstpProTcGuard HwMSTPEnabledStatus
  hwMstpProTcGuardThreshold Integer32
  hwMstpProTcNotifyProcess EnabledStatus
  hwMstpProRegionConfActive EnabledStatus
  hwMstpProLinkShareGuard EnabledStatus
  hwMstpConfigDegist OCTET STRING
  hwMstpProRegionConfShare EnabledStatus
  hwMstpProRowStatus RowStatus
  hwMstpProTcGuardInterval Integer32

HwMstpPortBindEntry  
SEQUENCE    
  hwMstpPortId1 Integer32
  hwMstpPortId2 Integer32
  hwMstpPortId3 Integer32
  hwMstpPortId4 Integer32
  hwMstpPortIdFlag Integer32
  hwMstpPortVlanListLow OCTET STRING
  hwMstpPortVlanListHigh OCTET STRING
  hwMstpProNewPortType INTEGER
  hwMstpProNewPortBpduVlan Integer32
  hwMstpPortBindRowStatus RowStatus

HwMstpProPortEntry  
SEQUENCE    
  hwMstpProPortState INTEGER
  hwMstpProPortPriority Integer32
  hwMstpProPortPathCost Integer32
  hwMstpProPortDesignatedRoot BridgeId
  hwMstpProPortDesignatedCost Integer32
  hwMstpProPortDesignatedBridge BridgeId
  hwMstpProPortDesignatedPort OCTET STRING
  hwMstpProPortStpEdgeport HwMSTPEnabledStatus
  hwMstpProPortStpPointToPoint INTEGER
  hwMstpProPortStpMcheck INTEGER
  hwMstpProPortStpTransLimit Integer32
  hwMstpProPortStpRXStpBPDU Counter32
  hwMstpProPortStpTXStpBPDU Counter32
  hwMstpProPortStpRXTCNBPDU Counter32
  hwMstpProPortStpTXTCNBPDU Counter32
  hwMstpProPortStpRXRSTPBPDU Counter32
  hwMstpProPortStpTXRSTPBPDU Counter32
  hwMstpProPortStpRXMSTPBPDU Counter32
  hwMstpProPortStpTXMSTPBPDU Counter32
  hwMstpProPortStpClearStatistics INTEGER
  hwMstpProPortStpDefaultPortCost INTEGER
  hwMstpProPortStpStatus HwMSTPEnabledStatus
  hwMstpProPortRootGuard HwMSTPEnabledStatus
  hwMstpProPortLoopGuard HwMSTPEnabledStatus
  hwMstpProPortCompliance INTEGER
  hwMstpProPortConfigDigestSnooping HwMSTPEnabledStatus
  hwMstpProPortNoAgreementCheck HwMSTPEnabledStatus
  hwMstpProPortTCNotify HwMSTPEnabledStatus
  hwMstpProPortType INTEGER

HwMstpProInstanceEntry  
SEQUENCE    
  hwMstpProInstanceBridgeID BridgeId
  hwMstpProInstanceBridgePriority Integer32
  hwMstpProInstanceDesignedRoot BridgeId
  hwMstpProInstanceRootPathCost Integer32
  hwMstpProInstanceRootPort Integer32
  hwMstpProInstanceRootType INTEGER
  hwMstpProInstanceRemainingHops Integer32
  hwMstpProInstanceAdminMappedVlanListLow OCTET STRING
  hwMstpProInstanceAdminMappedVlanListHigh OCTET STRING
  hwMstpProInstanceOperMappedVlanListLow OCTET STRING
  hwMstpProInstanceOperMappedVlanListHigh OCTET STRING
  hwMstpProInstanceRowStatus RowStatus

HwMstpProNewPortEntry  
SEQUENCE    
  hwMstpProNewPortState INTEGER
  hwMstpProNewPortPriority Integer32
  hwMstpProNewPortPathCost Integer32
  hwMstpProNewPortDesignatedRoot BridgeId
  hwMstpProNewPortDesignatedCost Integer32
  hwMstpProNewPortDesignatedBridge BridgeId
  hwMstpProNewPortDesignatedPort OCTET STRING
  hwMstpProNewPortStpEdgeport INTEGER
  hwMstpProNewPortStpPointToPoint INTEGER
  hwMstpProNewPortStpMcheck INTEGER
  hwMstpProNewPortStpTransLimit Integer32
  hwMstpProNewPortStpRXStpBPDU Counter32
  hwMstpProNewPortStpTXStpBPDU Counter32
  hwMstpProNewPortStpRXTCNBPDU Counter32
  hwMstpProNewPortStpTXTCNBPDU Counter32
  hwMstpProNewPortStpRXRSTPBPDU Counter32
  hwMstpProNewPortStpTXRSTPBPDU Counter32
  hwMstpProNewPortStpRXMSTPBPDU Counter32
  hwMstpProNewPortStpTXMSTPBPDU Counter32
  hwMstpProNewPortStpClearStatistics INTEGER
  hwMstpProNewPortStpDefaultPortCost INTEGER
  hwMstpProNewPortStpStatus EnabledStatus
  hwMstpProNewPortRootGuard EnabledStatus
  hwMstpProNewPortLoopGuard EnabledStatus
  hwMstpProNewPortCompliance INTEGER
  hwMstpProNewPortConfigDigestSnooping EnabledStatus
  hwMstpProNewPortNoAgreementCheck EnabledStatus
  hwMstpProNewPortVplsSubinterfaceEnable EnabledStatus
  hwMstpProNewPortBpduEncapsulation INTEGER
  hwMstpProNewPortBpduFilter INTEGER
  hwMstpProNewPortStpRXTC Counter32
  hwMstpProNewPortStpTXTC Counter32
  hwMstpProNewPortRole INTEGER

HwMstpPortTcSnoopingEntry  
SEQUENCE    
  hwMstpPortIfIndex Integer32
  hwMstpPortTcSnoopingNotifyTrill HwMSTPEnabledStatus

Defined Values

hwMstp 1.3.6.1.4.1.2011.5.25.42.4
This module include the information about MSTP protocol in the bridge. The information can be read and some of them can be set.
MODULE-IDENTITY    

hwL2Mgmt 1.3.6.1.4.1.2011.5.25.42
OBJECT IDENTIFIER    

hwMstpObjects 1.3.6.1.4.1.2011.5.25.42.4.1
OBJECT IDENTIFIER    

hwMstpStatus 1.3.6.1.4.1.2011.5.25.42.4.1.1
Whether the Bridge MSTP is enabled. Enable indicate that MSTP enable in the bridge; Disabled indicate that MSTP disable in the bridge. By default, the Bridge MSTP is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpForceVersion 1.3.6.1.4.1.2011.5.25.42.4.1.2
The mode of this Bridge spanning-tree protocol. At present, the bridge hold out STP compatible mode and MSTP . User can set the mode by command line. By default, the mode is MSTP.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stp(0), rstp(2), mstp(3)  

hwMstpDiameter 1.3.6.1.4.1.2011.5.25.42.4.1.3
The diameter of Bridge. It stands for the scope of the network. It affects the time that include hello time, forward delay time, maxage. Every bridge can set the diameter of Bridge, and it is effective when the bridge is root bridge. Effective in the CIST By default, the diameter is 7. The value of hwMstpDiameter is only unused(65535) when it is read.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 2..7 | 65535  

hwMstpBridgeMaxHops 1.3.6.1.4.1.2011.5.25.42.4.1.4
The maximum value of the Bridge hops. It can limit the scope of the bridge network. It is effective when the bridge is root bridge. The BPDU that the bridge receives from the Designed bridge will be dropped when the hops in the BPDU is zero . By default, the value is 20.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..40  

hwMstpMasterBridgeID 1.3.6.1.4.1.2011.5.25.42.4.1.5
The Bridge Identifier of the current Master Bridge. It is the root Bridge Identifier of the instance 0 in the region.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpMasterPathCost 1.3.6.1.4.1.2011.5.25.42.4.1.6
The CIST path cost from the transmitting Bridge to the Master Bridge. By default, the value is 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpBpduGuard 1.3.6.1.4.1.2011.5.25.42.4.1.7
Whether the Bridge BPDU Guard function is enabled. If the function is enabled, the port will shutdown when received BPDU and the port is configured as edgeport. The purpose of the function is to prevent the bridge from BPDU attacking. By default, the function is disabled
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpAdminFormatSelector 1.3.6.1.4.1.2011.5.25.42.4.1.8
The administrative Configuration Identifier Format Selector in use by the Bridge. This has a value of 0 indicate the format specified in the Standard of IEEE 802.1s. By default, the value is 0
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpAdminRegionName 1.3.6.1.4.1.2011.5.25.42.4.1.9
This MSTP administrative region name. It changes to hwMstpOperRegionName when user use the activing command to active the configuration of the region.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..32)  

hwMstpAdminRevisionLevel 1.3.6.1.4.1.2011.5.25.42.4.1.10
This MSTP administrative revision level. It changes to hwMstpOperRevisionLevel when user use the activing command to active the configuration of the region. By default, the value is 0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

hwMstpOperFormatSelector 1.3.6.1.4.1.2011.5.25.42.4.1.11
The operative Configuration Identifier Format Selector in use by the Bridge. This has a value of 0 indicate the format specified in the Standard of IEEE 802.1s. By default, the value is 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpOperRegionName 1.3.6.1.4.1.2011.5.25.42.4.1.12
This MSTP operative region name. It can be used to determine whether the region is the same region with the mapping between VLAN and instance and hwMstpOperRevisionLevel.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwMstpOperRevisionLevel 1.3.6.1.4.1.2011.5.25.42.4.1.13
This MSTP operative revision level. It can be used to determine whether the region is the same region with the mapping between VLAN and instance and hwMstpOperRegionName. By default, the value is 0
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

hwMstpRegionConfActive 1.3.6.1.4.1.2011.5.25.42.4.1.14
Active the region configuration. Generally, the value of the hwMstpRegionConfActive is disable, but the value will be set as enable if Net Manager want to active the configure of the region in the bridge. And then all manager configuration will change to operable configuration. The value of hwMstpRegionConfActive is only disable when it is read. It is only enable when it is set.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwMstpDefaultVlanAllo 1.3.6.1.4.1.2011.5.25.42.4.1.15
Set default configuration about VLAN allocation and all VLANs are mapped to CIST. The value of hwMstpDefaultVlanAllo is only unused(65535) when it is read. It is only enable(1) when it is set.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), unused(65535)  

hwMstpDefaultRegionName 1.3.6.1.4.1.2011.5.25.42.4.1.16
Set default region name. The value of hwMstpDefaultRegionName is only unused(65535) when it is read. It is only reset(1) when it is set.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), unused(65535)  

hwMstpPathCostStandard 1.3.6.1.4.1.2011.5.25.42.4.1.17
Path cost standard of the bridge. Value dot1d-1998 is IEEE 802.1d standard in 1998, value dot1t is IEEE 802.1t standard, and value legacy is a private legacy standard. The default path cost standard is 2(IEEE 802.1t standard).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dot1d1998(1), dot1t(2), legacy(3)  

hwMstpVIDAllocationTable 1.3.6.1.4.1.2011.5.25.42.4.1.18
The table includes the information of the VLAN with relation to the instance of MSTP.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpVIDAllocationEntry

hwMstpVIDAllocationEntry 1.3.6.1.4.1.2011.5.25.42.4.1.18.1
The table includes the information of the VLAN with relation to the instance of MSTP. The index of the table is vlanid. Default, the VLAN is in the CIST.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpVIDAllocationEntry  

hwMstpVID 1.3.6.1.4.1.2011.5.25.42.4.1.18.1.1
VLAN Identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..4094  

hwMstpAdminMstID 1.3.6.1.4.1.2011.5.25.42.4.1.18.1.2
Administrative Multiple spanning-tree instance Identifier. The relation between VLAN and Multiple spanning-tree instance is set by operation in the region, but it isn't effective if the configuration isn't actived. The scope of instance identifier is different, some versions are 0 to 48.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..4094  

hwMstpOperMstID 1.3.6.1.4.1.2011.5.25.42.4.1.18.1.3
Operative Multiple spanning-tree instance Identifier. The relation between VLAN and Multiple spanning-tree instance is effective in the bridge. The scope of instance identifier is different, some versions are 0 to 48.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..4094  

hwMstpInstanceTable 1.3.6.1.4.1.2011.5.25.42.4.1.19
The table includes the information of the instance.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpInstanceEntry

hwMstpInstanceEntry 1.3.6.1.4.1.2011.5.25.42.4.1.19.1
The table includes the information of the instance. The index of the table is Multiple spanning-tree instance Identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpInstanceEntry  

hwMstpInstanceID 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.1
Multiple spanning-tree instance Identifier. The scope of instance identifier is different, some versions are 0 to 48.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..4094  

hwMstpiBridgeID 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.2
The Bridge Identifier for the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpiBridgePriority 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.3
The Bridge Priority for the spanning tree instance identified by MSTID. Step of 4096.For example, we can set the Priority of the bridge such as 0, 4096, 8192 etc. It can be used to determined whether the bridge is the root of the spanning tree.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..61440  

hwMstpiDesignedRoot 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.4
The Bridge Identifier of the Root Bridge for the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpiRootPathCost 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.5
The path cost from the transmitting Bridge to the Root Bridge for the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpiRootPort 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.6
The root port for the spanning tree instance identified by the MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpiRootType 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.7
Config this Bridge as a primary root or secondary root / cancel the root for this spanning tree instance identified by MSTID. The current value of the hwMstpiRootType is the value that was set recently.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER normal(0), secondary(1), primary(2)  

hwMstpiRemainingHops 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.8
The remaining hops of the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpiAdminMappedVlanListLow 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.9
The lower part of administrative VLAN list mapped to the spanning tree instance identified by MSTID.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpiAdminMappedVlanListHigh 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.10
The higher part of administrative VLAN list mapped to the spanning tree instance identified by MSTID.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpiOperMappedVlanListLow 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.11
The lower part of operative VLAN list mapped to the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpiOperMappedVlanListHigh 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.12
The higher part of operative VLAN list mapped to the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpiRowStatus 1.3.6.1.4.1.2011.5.25.42.4.1.19.1.13
To band MSTI and VLAN List. Operation of CreateAndGo can be used to create a new instance, and operation of Destroy be used to destroy an existent instance. But these operation won't be effective if they are not actived by executing command of active region-configuration or setting mib node of hwMstpRegionConfActive.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMstpPortTable 1.3.6.1.4.1.2011.5.25.42.4.1.20
The table includes the information of the port of the multiple spanning tree instance.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpPortEntry

hwMstpPortEntry 1.3.6.1.4.1.2011.5.25.42.4.1.20.1
The table includes the information of the port of the multiple spanning tree instance. The index of the table is the aggregation of multiple spanning tree instance identifier and port index.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpPortEntry  

hwMstpiPortIndex 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.1
The index of the bridge port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpiState 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.2
The current state of the port. It must be disabled, discarding, learning or forwarding.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), discarding(2), learning(4), forwarding(5)  

hwMstpiPortPriority 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.3
The value of the priority field which is contained in the first (in network byte order) four bits of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of mstiPortIndex. And step of 16. It is the priority of the port in the multiple spanning tree instance, and it can be used to determine the role of the port in the multiple spanning tree.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..240  

hwMstpiPathCost 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.4
the path cost of paths with which the package passes the port. The range of path cost is 1..65535 for 802.1d standard, is 1..200000000 for 802.1t standard, and is 1..200000 for the legacy standard.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..200000000  

hwMstpiDesignatedRoot 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.5
The Bridge Identifier of the Root Bridge for the port of the Spanning Tree instance identified by the MSTID
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpiDesignatedCost 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.6
The path cost of the designated port of the segment connected to this port. This value is compared to the Root Path Cost field in received bridge BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpiDesignatedBridge 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.7
The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpiDesignatedPort 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.8
The port Identifier of the port on the Designated Bridge for this port's segment.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

hwMstpiStpPortEdgeport 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.9
Whether the port fast is enabled. By default, there is no configuration on the port. When the port is the edge port, it can change to forwarding state . We can set the value. Disable indicates that we make the port not to be a edge port. Enable indicates that we make the port to be a edge port. The port's edge port state is same in all instance of MSTP. When set the value, the hwMstpInstanceID must be 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2), undo(3)  

hwMstpiStpPortPointToPoint 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.10
Whether the port connects the point to point link. If user set the port as a point to point port, the port is a point to point port in all instance of the MSTP. If user set the port as a point to point port but the port isn't, the mstp may import temporary loop. So user can use the default. When set the value, the hwMstpInstanceID must be 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forceTrue(1), forceFalse(2), auto(3)  

hwMstpiStpMcheck 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.11
When root interface is changed from STP mode to MSTP mode, the appointed interface can not switch to MSTP mode automatically. At the time, you need switch to MSTP mode with hand by set Mcheck value to enable(1). The value of hwMstpiStpMcheck is unused(65535) when it is read.The value of hwMstpiStpMcheck must be enable(1) when it is set. When set the value, the hwMstpInstanceID must be 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), unused(65535)  

hwMstpiStpTransLimit 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.12
The value is used to set BPDU maximum transmission rate of the port . When the value is set, the hwMstpInstanceID must be 0. If value is set 0, the transmit limit of the port is equal to the hwMstpTransmitLimitDefault value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

hwMstpiStpRXStpBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.13
The number of received Config BPDU. Effective in CIST.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpiStpTXStpBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.14
The number of transmitted Config BPDU. Effective in CIST.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpiStpRXTCNBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.15
The number of received TCN BPDU. Effective in CIST.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpiStpTXTCNBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.16
The number of transmitted TCN BPDU. Effective in CIST.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpiStpRXRSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.17
The number of received RST BPDU. Effective in CIST.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpiStpTXRSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.18
The number of transmitted RST BPDU. Effective in CIST.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpiStpRXMSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.19
The number of received MST BPDU. Effective in CIST.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpiStpTXMSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.20
The number of transmitted MST BPDU. Effective in CIST.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpiStpClearStatistics 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.21
Clear the spanning tree statistic. Effective in CIST. The value of hwMstpiStpClearStatistics is unused(65535) when it is read. The value of hwMstpiStpClearStatistics must be clear(1) when it is set.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), unused(65535)  

hwMstpiStpDefaultPortCost 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.22
Set default port path cost. The value of hwMstpiStpDefaultPortCost is unused(65535) when it is read. The value of hwMstpiStpDefaultPortCost must be reset(1) when it is set.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), unused(65535)  

hwMstpiStpStatus 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.23
Whether the spanning tree protocol is enabled on this port. Effective in CIST. When set the value, the hwMstpInstanceID must be 0.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpiPortRootGuard 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.24
Whether the root guard is enabled. The function is to prevent the port from receiving the BPDU , the priority of which is above the priority of the port. When set the value, the hwMstpInstanceID must be 0.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpiPortLoopGuard 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.25
Whether the loop protection is enabled. When set the value, the hwMstpInstanceID must be 0.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpPortCompliance 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.26
The value of this object identifies the protocol format of the MSTP packet sent and received on the port. The protocol format can be one of the following: 1: auto (the self-adaptive protocol format) 2: dotls (the standard IEEE 802.1s format) 3: legacy (the private protocol format) By default, the protocol format of the MSTP packet is self-adaptive, that is, auto(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), dotls(2), legacy(3)  

hwMstpConfigDigestSnooping 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.27
This object indicates whether the digest snooping function is enabled on the port: 1: enabled 2: disabled By default, the function is not enabled. In other words, the default value is disabled(2).
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpNoAgreementCheck 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.30
Whether enhance agreement is enabled. When Huawei datacomm devices running the VRP are internetworking with non-Huawei devices, you need to enable this on Huawei devices to configure the mode of the fast transition mechanism the same as that on non-Huawei devices.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpPortTCNotify 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.31
The main interface notifies its sub-interfaces to update MAC entries and ARP entries after receiving a TC message. This prevents services from being interrupted.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpiStpPortBpduFilter 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.32
Whether the port BPDU-filter is enabled. By default, there is no configuration on the port. The port will not send or receive BPDUs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2), undo(3)  

hwMstpiPortRole 1.3.6.1.4.1.2011.5.25.42.4.1.20.1.33
Indicates the port role on a particular instance.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), alternate(2), backup(3), root(4), designated(5), master(6)  

hwMstpSnooping 1.3.6.1.4.1.2011.5.25.42.4.1.21
when the device's interface receive TCN, the servers is normal in device where MSTP is disable. By default, the value is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwMstpAccessoryTable 1.3.6.1.4.1.2011.5.25.42.4.1.22
The table of MSTP Accessory Information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpAccessoryEntry

hwMstpAccessoryEntry 1.3.6.1.4.1.2011.5.25.42.4.1.22.1
The table entry of MSTP Accessory Information.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpAccessoryEntry  

hwMstpAccessoryIndex 1.3.6.1.4.1.2011.5.25.42.4.1.22.1.1
The index of the Accessory Commands of MSTP.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..512  

hwMstpBackupReplyAgreement 1.3.6.1.4.1.2011.5.25.42.4.1.22.1.2
When the port of device, which played the backup or alternate role, receives the BPDU message with high priority, and the proposal flag of this message was set. The BPDU message can be send from this port immediately, the agreement flag was set of this BPDU message.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwMstpStpNoAgreementCheck 1.3.6.1.4.1.2011.5.25.42.4.1.22.1.3
when the port is root, calculating allsyned without check syned flag of root.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwMstpProTable 1.3.6.1.4.1.2011.5.25.42.4.1.23
The MSTP process information table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpProEntry

hwMstpProEntry 1.3.6.1.4.1.2011.5.25.42.4.1.23.1
Entry of the MSTP process information table.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpProEntry  

hwMstpProID 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.1
MSTP process identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..288  

hwMstpProStpState 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.4
Whether Spannting-Tree is enabled or not on a MSTP process.
Status: current Access: read-create
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProPriority 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.5
The priority for the MSTP process spanning tree, step of 4096. For example, we can set the Priority of the bridge such as 0, 4096, 8192 etc. It can be used to determined whether the process is the root of the whole spanning tree. The default value is 32768.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..61440  

hwMstpProRootType 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.6
Config this MSTP process as a primary root, secondary root or cancel the root for spanning tree. The default value is not a primary or secondary root.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER normal(0), secondary(1), primary(2)  

hwMstpProForceVersion 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.7
Mode of Spanning-Tree portocol on a MSTP process.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER stp(0), rstp(2), mstp(3)  

hwMstpProBpduGuard 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.8
Whether BPDU portection is enabled or not on a MSTP process.
Status: current Access: read-create
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProDiameter 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.9
The Spanning-Tree diameter of a MSTP process, the default value is 7. The value of hwMstpProDiameter is only unused(65535) when it is read.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 2..7 | 65535  

hwMstpProConvergeMode 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.10
Spanning-Tree converge mode. When the mode is fast, MAC entries and ARP entries will be deleted. When the mode is normal, the entries will be aged.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER fast(1), normal(2)  

hwMstpProMaxHops 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.11
Maxhops of a MSTP process, the default value is 20.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..40  

hwMstpProMCheck 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.12
Whether to do Mcheck function on a MSTP process.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(1), unused(65535)  

hwMstpProPathCostStandard 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.13
Path cost standard of a MSTP process, the fault value is dot1t.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER dot1d1998(1), dot1t(2), legacy(3)  

hwMstpProHelloTime 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.14
Hello time of a MSTP process, the default value is 200 centiseconds.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 100..1000  

hwMstpProFwdDelay 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.15
Forward delay of a MSTP process, the default value is 1500 centiseconds.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 400..3000  

hwMstpProMaxAge 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.16
Max age of a MSTP process, the default value is 2000 centiseconds.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 600..4000  

hwMstpProTimerFactor 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.17
Timer factor, which is used in loop protection, the default value is 3.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..10  

hwMstpProTCNotify 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.18
The current MSTP process notifies the specified STP instance in MSTP process 0 to update MAC entries and ARP entries after receiving a TC message. This prevents services from being interrupted.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..7)  

hwMstpProNoLinkSharePortList 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.19
The port list participates in the status calculation of a specified MSTP process witch no-link-share method.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwMstpProLinkSharePortList 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.20
The port list participates in the status calculation of a specified MSTP process witch link-share method.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwMstpProTcGuard 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.21
Whether the TC protection function is enabled on the MSTP process. If the function is enabled, the TC message exceeded threshold will be defered to deal with at the end of TC protection time.
Status: current Access: read-create
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProTcGuardThreshold 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.22
The threshold of the TC protection on the MSTP process. It decided the maximum TC messages can be dealt with in a TC protection time.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..255  

hwMstpProTcNotifyProcess 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.23
Whether the current MSTP process notifies MSTP process 0 to update MAC entries and ARP entries after receiving a TC message.
Status: current Access: read-create
OBJECT-TYPE    
  EnabledStatus  

hwMstpProRegionConfActive 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.24
Active the region configuration. Generally, the value of the hwMstpProRegionConfActive is disable, but the value will be set as enable if Net Manager want to active the configure of the region in the bridge. And then all manager configuration will change to operable configuration. The value of hwMstpRegionConfActive is only disable when it is read. It is only enable when it is set.
Status: current Access: read-create
OBJECT-TYPE    
  EnabledStatus  

hwMstpProLinkShareGuard 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.25
Whether the Link-share Guard function is enabled on the MSTP process. If the function is enabled, the root Guard function will also work on port in all instance besides instance 0, when the link between the ports either of which is in Link_share mode broken down.
Status: current Access: read-create
OBJECT-TYPE    
  EnabledStatus  

hwMstpConfigDegist 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.26
This MSTP region-configuration digest. It can be used to determine whether the region is the same region with another one.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpProRegionConfShare 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.27
Suggesting that whether all the process will share the same Region-config with process 0. If the function is enable, all the existing process will share the same Region-config with process 0.
Status: current Access: read-only
OBJECT-TYPE    
  EnabledStatus  

hwMstpProRowStatus 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.30
MSTP process table rowstatus.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMstpProTcGuardInterval 1.3.6.1.4.1.2011.5.25.42.4.1.23.1.31
The value is the tc-protection interval time. If the value is set 0, the tc guard interval value is euqal to the hello time.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..600  

hwMstpPortBindTable 1.3.6.1.4.1.2011.5.25.42.4.1.24
The port bind table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpPortBindEntry

hwMstpPortBindEntry 1.3.6.1.4.1.2011.5.25.42.4.1.24.1
The port bind entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpPortBindEntry  

hwMstpPortId1 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.1
The port external port index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

hwMstpPortId2 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.2
The port external port index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

hwMstpPortId3 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.3
The port external port index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

hwMstpPortId4 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.4
The port external port index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

hwMstpPortIdFlag 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.5
The port type.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

hwMstpPortVlanListLow 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.6
The VLAN list of port.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpPortVlanListHigh 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.7
The VLAN list of port.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpProNewPortType 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.8
An interface to participate in the status calculation of link-share , no-link-share or no-link-share with VLAN Spanning Tree processes.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER normal(1), nolinkshare(2), linkshare(3), nolinksharewithvlan(4)  

hwMstpProNewPortBpduVlan 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.9
The VLAN of port is BPDU VLAN.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..4094  

hwMstpPortBindRowStatus 1.3.6.1.4.1.2011.5.25.42.4.1.24.1.100
MSTP port binding table rowstatus.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMstpProPortTable 1.3.6.1.4.1.2011.5.25.42.4.1.25
The table includes the information of the port of the MSTP process.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpProPortEntry

hwMstpProPortEntry 1.3.6.1.4.1.2011.5.25.42.4.1.25.1
The entry of the MSTP process port information table.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpProPortEntry  

hwMstpProPortState 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.2
The current state of the port in MSTP process. It must be disabled, discarding, learning or forwarding.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), discarding(2), learning(4), forwarding(5)  

hwMstpProPortPriority 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.3
The value of the priority field which is contained in the first (in network byte order) four bits of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of hwMstpiPortIndex. And step of 16. It is the priority of the port in the MSTP process, and it can be used to determine the role of the port in the MSTP process Spanning Tree.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..240  

hwMstpProPortPathCost 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.4
The path cost of paths with which the package passes the port. The range of path cost is 1..65535 for 802.1d standard, is 1..200000000 for 802.1t standard, and is 1..200000 for the legacy standard.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..200000000  

hwMstpProPortDesignatedRoot 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.5
The Bridge Identifier of the Root Bridge for the port of the MSTP process Spanning Tree.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpProPortDesignatedCost 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.6
The path cost of the designated port of the segment connected to this port. This value is compared to the Root Path Cost field in received bridge BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpProPortDesignatedBridge 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.7
The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpProPortDesignatedPort 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.8
The Port Identifier of the port on the Designated Bridge for this port's segment.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

hwMstpProPortStpEdgeport 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.9
Whether the port fast is enabled in the MSTP process. When the port is the edge port, it can change to forwarding state immediately.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProPortStpPointToPoint 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.10
Whether the port connects the point to point link. If user set the port as a point to point port, the port is a point to point port in the MSTP process. If user set the port as a point to point port but the port isn't, the mstp may import temporary loop. So user can use the default.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forceTrue(1), forceFalse(2), auto(3)  

hwMstpProPortStpMcheck 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.11
When root interface is changed from STP mode to RSTP or MSTP mode, the appointed interface can not switch to RSTP or MSTP mode automatically. At the time, you need switch back with hand by set Mcheck value to enable(1). The value unused(65535) when it is read.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), unused(65535)  

hwMstpProPortStpTransLimit 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.12
The value used by the port transmit state machine to limit the maximum transmission rate.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

hwMstpProPortStpRXStpBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.13
The number of received Config BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProPortStpTXStpBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.14
The number of transmitted Config BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProPortStpRXTCNBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.15
The number of received TCN BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProPortStpTXTCNBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.16
The number of transmitted TCN BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProPortStpRXRSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.17
The number of received RST BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProPortStpTXRSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.18
The number of transmitted RST BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProPortStpRXMSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.19
The number of received MST BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProPortStpTXMSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.20
The number of transmitted MST BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProPortStpClearStatistics 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.21
Clear the Spanning Tree statistics in specified MSTP process. The value is unused(65535) when it is read. The value must be clear(1) when it is set.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), unused(65535)  

hwMstpProPortStpDefaultPortCost 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.22
Set default port path cost.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), unused(65535)  

hwMstpProPortStpStatus 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.23
Whether the Spanning Tree Protocol is enabled on this port.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProPortRootGuard 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.24
Whether the root guard is enabled. The function is to prevent the port from receiving the BPDUs, the priority of which is above the priority of the port.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProPortLoopGuard 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.25
Whether the loop protection is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProPortCompliance 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.26
The value of this object identifies the protocol format of the MSTP packet sent and received on the port. The protocol format can be one of the following: 1: auto (the self-adaptive protocol format) 2: dotls (the standard IEEE 802.1s format) 3: legacy (the private protocol format) By default, the protocol format of the MSTP packet is self-adaptive, that is, auto(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), dotls(2), legacy(3)  

hwMstpProPortConfigDigestSnooping 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.27
This object indicates whether the digest snooping function is enabled on the port: 1: enabled 2: disabled By default, the function is not enabled. In other words, the default value is disabled(2).
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProPortNoAgreementCheck 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.30
Whether enhance agreement is enabled. When Huawei datacomm devices running the VRP are internetworking with non-Huawei devices, you need to enable this on Huawei devices to configure the mode of the fast transition mechanism the same as that on non-Huawei devices.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProPortTCNotify 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.31
The main interface notifies its sub-interfaces to update MAC entries and ARP entries after receiving a TC message. This prevents services from being interrupted.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpProPortType 1.3.6.1.4.1.2011.5.25.42.4.1.25.1.32
An interface to participate in the status calculation of link-share or no-link-share Spanning Tree processes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), nolinkshare(1), linkshare(2)  

hwMstpTcGuard 1.3.6.1.4.1.2011.5.25.42.4.1.26
Whether the Bridge TC Guard function is enabled. If the function is enabled, the TC message in each instance exceeded threshold will be defered to deal with at the end of TC protection time. By default, the function is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpTcGuardThreshold 1.3.6.1.4.1.2011.5.25.42.4.1.27
The threshold of the Bridge TC Guard. It decided the maximum TC message in each instance can be dealt with in a TC protection time.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

hwMstpProInstanceTable 1.3.6.1.4.1.2011.5.25.42.4.1.28
The MSTP process instance information table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpProInstanceEntry

hwMstpProInstanceEntry 1.3.6.1.4.1.2011.5.25.42.4.1.28.1
The entry of the MSTP process instance information table.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpProInstanceEntry  

hwMstpProInstanceBridgeID 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.1
The Bridge Identifier for the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpProInstanceBridgePriority 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.2
The Bridge Priority for the spanning tree instance identified by MSTID. Step of 4096.For example, we can set the Priority of the bridge such as 0, 4096, 8192 etc. It can be used to determined whether the bridge is the root of the spanning tree.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..61440  

hwMstpProInstanceDesignedRoot 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.3
The Bridge Identifier of the Root Bridge for the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpProInstanceRootPathCost 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.4
The path cost from the transmitting Bridge to the Root Bridge for the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpProInstanceRootPort 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.5
The root port for the spanning tree instance identified by the MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpProInstanceRootType 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.6
Config this Bridge as a primary root or secondary root / cancel the root for this spanning tree instance identified by MSTID. The current value of the hwMstpiRootType is the value that was set recently.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER normal(0), secondary(1), primary(2)  

hwMstpProInstanceRemainingHops 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.7
The remaining hops of the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpProInstanceAdminMappedVlanListLow 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.8
The lower part of administrative VLAN list mapped to the spanning tree instance identified by MSTID.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpProInstanceAdminMappedVlanListHigh 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.9
The higher part of administrative VLAN list mapped to the spanning tree instance identified by MSTID.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpProInstanceOperMappedVlanListLow 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.10
The lower part of operative VLAN list mapped to the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpProInstanceOperMappedVlanListHigh 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.11
The higher part of operative VLAN list mapped to the spanning tree instance identified by MSTID.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwMstpProInstanceRowStatus 1.3.6.1.4.1.2011.5.25.42.4.1.28.1.100
To band MSTI and VLAN List. Operation of CreateAndGo can be used to create a new instance, and operation of Destroy be used to destroy an existent instance. But these operation won't be effective if they are not actived by executing command of active region-configuration or setting mib node of hwMstpRegionConfActive.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMstpProNewPortTable 1.3.6.1.4.1.2011.5.25.42.4.1.29
The table includes the information of the port of the MSTP process.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpProNewPortEntry

hwMstpProNewPortEntry 1.3.6.1.4.1.2011.5.25.42.4.1.29.1
The entry of the MSTP process port information table.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpProNewPortEntry  

hwMstpProNewPortState 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.1
The current state of the port in MSTP process. It must be disabled, discarding, learning or forwarding.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), discarding(2), learning(4), forwarding(5)  

hwMstpProNewPortPriority 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.2
The value of the priority field which is contained in the first (in network byte order) four bits of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of hwMstpiPortIndex. And step of 16. It is the priority of the port in the MSTP process, and it can be used to determine the role of the port in the MSTP process Spanning Tree.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..240  

hwMstpProNewPortPathCost 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.3
The path cost of paths with which the package passes the port. The range of path cost is 1..65535 for 802.1d standard, is 1..200000000 for 802.1t standard, and is 1..200000 for the legacy standard.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..200000000  

hwMstpProNewPortDesignatedRoot 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.4
The Bridge Identifier of the Root Bridge for the port of the MSTP process Spanning Tree.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpProNewPortDesignatedCost 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.5
The path cost of the designated port of the segment connected to this port. This value is compared to the Root Path Cost field in received bridge BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMstpProNewPortDesignatedBridge 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.6
The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

hwMstpProNewPortDesignatedPort 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.7
The port identifier of the port on the Designated Bridge for this port's segment.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

hwMstpProNewPortStpEdgeport 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.8
Whether the port fast is enabled in the MSTP process. By default, there is no configuration on the port. When the port is the edge port, it can change to forwarding state immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2), undo(3)  

hwMstpProNewPortStpPointToPoint 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.9
Whether the port connects the point to point link. If user set the port as a point to point port, the port is a point to point port in the MSTP process. If user set the port as a point to point port but the port isn't, the mstp may import temporary loop. So user can use the default.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forceTrue(1), forceFalse(2), auto(3)  

hwMstpProNewPortStpMcheck 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.10
When root interface is changed from STP mode to RSTP or MSTP mode, the appointed interface can not switch to RSTP or MSTP mode automatically. At the time, you need switch back with hand by set Mcheck value to enable(1). The value unused(65535) when it is read.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), unused(65535)  

hwMstpProNewPortStpTransLimit 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.11
The value is used to set BPDU maximum transmission rate of the port. If value is set 0, the transmit limit of the port is equal to the wMstpTransmitLimitDefault value
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

hwMstpProNewPortStpRXStpBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.12
The number of received Config BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortStpTXStpBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.13
The number of transmitted Config BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortStpRXTCNBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.14
The number of received TCN BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortStpTXTCNBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.15
The number of transmitted TCN BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortStpRXRSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.16
The number of received RST BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortStpTXRSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.17
The number of transmitted RST BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortStpRXMSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.18
The number of received MST BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortStpTXMSTPBPDU 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.19
The number of transmitted MST BPDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortStpClearStatistics 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.20
Clear the Spanning Tree statistics in specified MSTP process. The value is unused(65535) when it is read. The value must be clear(1) when it is set.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), unused(65535)  

hwMstpProNewPortStpDefaultPortCost 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.21
Set default port path cost.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), unused(65535)  

hwMstpProNewPortStpStatus 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.22
Whether the Spanning Tree Protocol is enabled on this port.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

hwMstpProNewPortRootGuard 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.23
Whether the root guard is enabled. The function is to prevent the port from receiving the BPDUs, the priority of which is above the priority of the port.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

hwMstpProNewPortLoopGuard 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.24
Whether the loop protection is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

hwMstpProNewPortCompliance 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.25
The value of this object identifies the protocol format of the MSTP packet sent and received on the port. The protocol format can be one of the following: 1: auto (the self-adaptive protocol format) 2: dotls (the standard IEEE 802.1s format) 3: legacy (the private protocol format) By default, the protocol format of the MSTP packet is self-adaptive, that is, auto(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), dotls(2), legacy(3)  

hwMstpProNewPortConfigDigestSnooping 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.26
This object indicates whether the digest snooping function is enabled on the port: 1: enabled 2: disabled By default, the function is not enabled. In other words, the default value is disabled(2).
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

hwMstpProNewPortNoAgreementCheck 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.27
Whether enhance agreement is enabled. When Huawei datacomm devices running the VRP are internetworking with non-Huawei devices, you need to enable this on Huawei devices to configure the mode of the fast transition mechanism the same as that on non-Huawei devices.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

hwMstpProNewPortVplsSubinterfaceEnable 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.28
The main interface notifies its sub-interfaces to update MAC entries and ARP entries after receiving a TC message. This prevents services from being interrupted.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

hwMstpProNewPortBpduEncapsulation 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.29
The value of this object identifies the protocol format of the BPDU sent on the port. The protocol format can be one of the following: 1: vbst (the VBST format) 2: stp (the STP format) By default, the BPDU format of the MSTP packet is stp(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER vbst(1), stp(2)  

hwMstpProNewPortBpduFilter 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.30
Whether the port BPDU-filter is enabled. By default, there is no configuration on the port. The port will not send or receive BPDUs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2), undo(3)  

hwMstpProNewPortStpRXTC 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.31
The number of TC BPDUs received by the port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortStpTXTC 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.32
The number of TC BPDUs sent by the port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hwMstpProNewPortRole 1.3.6.1.4.1.2011.5.25.42.4.1.29.1.33
Indicates the port role on a particular instance.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), alternate(2), backup(3), root(4), designated(5), master(6)  

hwMstpEdgedPortDefault 1.3.6.1.4.1.2011.5.25.42.4.1.30
When the stp edged-port default is enabled. By default,the port enabled stp is edged-port .
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpBpduFilterPortDefault 1.3.6.1.4.1.2011.5.25.42.4.1.31
When the stp BPDU-filter default is enabled. By default,the stp BPDU filter function is enabled .
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpTransmitLimitDefault 1.3.6.1.4.1.2011.5.25.42.4.1.32
The value is used to set BPDU maximum transmission rate of all port in the device.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

hwMstpPwName 1.3.6.1.4.1.2011.5.25.42.4.1.33
Pw name
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

hwMstpPortTcSnoopingTable 1.3.6.1.4.1.2011.5.25.42.4.1.34
The table includes the information of the port of the STP TC snooping.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMstpPortTcSnoopingEntry

hwMstpPortCountUpperThreshold 1.3.6.1.4.1.2011.5.25.42.4.1.35
The value of this object identifies the upper threshold for the number of Up STP-capable interfaces.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..65535  

hwMstpPortCountLowerThreshold 1.3.6.1.4.1.2011.5.25.42.4.1.36
The value of this object identifies the lower threshold for the number of Up STP-capable interfaces.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..65535  

hwMstpPortTcSnoopingEntry 1.3.6.1.4.1.2011.5.25.42.4.1.34.1
The entry of the MSTP TC snooping port information table.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMstpPortTcSnoopingEntry  

hwMstpPortIfIndex 1.3.6.1.4.1.2011.5.25.42.4.1.34.1.1
The ifIndex of the port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwMstpPortTcSnoopingNotifyTrill 1.3.6.1.4.1.2011.5.25.42.4.1.34.1.2
This object indicates whether the TC snooping notify TRILL function is enabled on the port: 1: enabled 2: disabled By default, the function is not enabled. In other words, the default value is disabled(2).
Status: current Access: read-write
OBJECT-TYPE    
  HwMSTPEnabledStatus  

hwMstpTraps 1.3.6.1.4.1.2011.5.25.42.4.2
Definition point for Mstp notifications.
Status: current Access: read-write
OBJECT-IDENTITY    

hwMstpiPortStateForwarding 1.3.6.1.4.1.2011.5.25.42.4.2.1
The SNMP trap that is generated when a port turns into forwarding state from other state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpiPortStateDiscarding 1.3.6.1.4.1.2011.5.25.42.4.2.2
The SNMP trap that is generated when a port turns into discarding state from forwarding state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpiBridgeLostRootPrimary 1.3.6.1.4.1.2011.5.25.42.4.2.3
The SNMP trap that is generated when the bridge is no longer the root bridge of the instance. Another switch with higher priority has already been the root bridge of the instance.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpiPortRootGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.4
The SNMP trap that is generated when a root-guard port receives a superior message on the relevant instance.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpiPortBpduGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.5
The SNMP trap that is generated when an edged port of the BPDU-guard switch receives BPDU packets.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpiPortLoopGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.6
The SNMP trap that is generated when an Alternate-Port or Root-Port is aged out.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpiEdgePortChanged 1.3.6.1.4.1.2011.5.25.42.4.2.7
When the edged-port receives a BPDU packet, the edged-port attribute will be disabled. Then the SNMP trap is generated.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProPortStateForwarding 1.3.6.1.4.1.2011.5.25.42.4.2.8
The SNMP trap that is generated when a port turns into forwarding state from other state in the MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProPortStateDiscarding 1.3.6.1.4.1.2011.5.25.42.4.2.9
The SNMP trap that is generated when a port turns into discarding state from forwarding state in the MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProBridgeLostRootPrimary 1.3.6.1.4.1.2011.5.25.42.4.2.10
The SNMP trap that is generated when the bridge is no longer the root bridge of the MSTP process Spanning Tree. Another switch with higher priority has already been the root bridge.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProPortRootGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.11
The SNMP trap that is generated when a root-guard port receives a superior message in the MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProPortBpduGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.12
The SNMP trap that is generated when an edged port of the BPDU-guard MSTP process receives BPDU packets.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProPortLoopGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.13
The SNMP trap that is generated when an Alternate-Port or Root-Port is aged out in the MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProEdgePortChanged 1.3.6.1.4.1.2011.5.25.42.4.2.14
When the edged-port receives a BPDU packet, the edged-port attribute will be disabled. Then the SNMP trap is generated.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpiTcGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.15
The SNMP trap that is generated when an MSTP instance receive TC BPDUs' number exceeds the threshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProTcGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.16
The SNMP trap that is generated when an MSTP process receive TC BPDUs' number exceeds the threshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProRootChanged 1.3.6.1.4.1.2011.5.25.42.4.2.17
The SNMP trap that is generated when the root bridge of an instance of a MSTP process changed
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProNewPortStateForwarding 1.3.6.1.4.1.2011.5.25.42.4.2.18
Specify that the status of the port STP becomes Forwarding in MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProNewPortStateDiscarding 1.3.6.1.4.1.2011.5.25.42.4.2.19
Specify that the status of the port STP becomes Discarding in MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProNewBridgeLostRootPrimary 1.3.6.1.4.1.2011.5.25.42.4.2.20
Specify that the switch loses the position of root bridge in MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProNewPortRootGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.21
Specify that a designated port receives a BPDU packet with the priority higher than that of the root bridge when root bridge protection is enabled in MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProNewPortBpduGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.22
Specify that the edge port receives the BPDU packets when BPDU protection was enabled in MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProNewPortLoopGuarded 1.3.6.1.4.1.2011.5.25.42.4.2.23
Specify that the root port has not received any BPDU packets for a long time when loop protection is enabled in MSTP process.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProNewEdgePortChanged 1.3.6.1.4.1.2011.5.25.42.4.2.24
Specify that the edge port is invalid because of receiving a BPDU packet.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpProLoopbackDetected 1.3.6.1.4.1.2011.5.25.42.4.2.25
When port detected loopback, block the port and arise trap.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpPortCountExceedThreshold 1.3.6.1.4.1.2011.5.25.42.4.2.26
This notification indicates that the number of Up STP-capable interfaces exceeded the upper threshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpPortCountExceedThresholdResume 1.3.6.1.4.1.2011.5.25.42.4.2.27
This notification indicates that the number of Up STP-capable interfaces fell below the lower threshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMstpConformance 1.3.6.1.4.1.2011.5.25.42.4.3
OBJECT IDENTIFIER    

hwMstpGroups 1.3.6.1.4.1.2011.5.25.42.4.3.1
OBJECT IDENTIFIER    

hwMstpBridgeInfoGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.1
A collection of objects indicating the necessary capabilites of the bridge device which is running the multi spanning tree protocol.
Status: current Access: read-write
OBJECT-GROUP    

hwMstpVlanInfoGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.2
A collection of objects describes the attribute of the VLAN in the multi spanning tree protocol. They are necessary to find the relation between VLAN and instance by the VLAN identifier.
Status: current Access: read-write
OBJECT-GROUP    

hwMstpInstanceInfoGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.3
A collection of objects describes the attribute of the instance in the multi spanning tree protocol.
Status: current Access: read-write
OBJECT-GROUP    

hwMstpPortInfoGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.4
A collection of objects is necessary to show the information of the port in the bridge in the multi spanning tree protocol.
Status: current Access: read-write
OBJECT-GROUP    

hwMstpAccessoryGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.5
MSTP accessory group.
Status: current Access: read-write
OBJECT-GROUP    

hwMstpNotificationGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.6
Notification.
Status: current Access: read-write
NOTIFICATION-GROUP    

hwMstpProGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.7
MSTP process group.
Status: current Access: read-write
OBJECT-GROUP    

hwMstpProPortInfoGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.8
A collection of objects is necessary to show the information of the port in the bridge in the multi spanning tree protocol.
Status: current Access: read-write
OBJECT-GROUP    

hwMstpProNotificationGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.9
MSTP process notification.
Status: current Access: read-write
NOTIFICATION-GROUP    

hwMstpProInstanceInfoGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.10
MSTP process instance group.
Status: current Access: read-write
OBJECT-GROUP    

hwMstpPortTcSnoopingGroup 1.3.6.1.4.1.2011.5.25.42.4.3.1.11
MSTP TC snooping group
Status: current Access: read-write
OBJECT-GROUP    

hwMstpCompliances 1.3.6.1.4.1.2011.5.25.42.4.3.2
OBJECT IDENTIFIER    

hwMstpCompliance 1.3.6.1.4.1.2011.5.25.42.4.3.2.1
The compliance statement for device support of Priority and Multicast Filtering extended bridging services.
Status: current Access: read-write
MODULE-COMPLIANCE