HUAWEI-MPLSOAM-PS-MIB

File: HUAWEI-MPLSOAM-PS-MIB.mib (20513 bytes)

Imported modules

HUAWEI-MPLSOAM-MIB IF-MIB SNMPv2-CONF
SNMPv2-SMI SNMPv2-TC

Imported symbols

hwMplsOam InterfaceIndex OBJECT-GROUP
MODULE-COMPLIANCE NOTIFICATION-GROUP IpAddress
Integer32 Unsigned32 OBJECT-TYPE
NOTIFICATION-TYPE RowStatus TruthValue

Defined Types

HwMplsPsEntry  
SEQUENCE    
  hwMplsPsIndex Unsigned32
  hwMplsPsType Integer32
  hwMplsPsWorkTunnName OCTET STRING
  hwMplsPsWorkTunnId Integer32
  hwMplsPsProtectTunnName OCTET STRING
  hwMplsPsProtectTunnId Integer32
  hwMplsPsRevertiveMode Integer32
  hwMplsPsWTR Integer32
  hwMplsPsHoldOff Integer32
  hwMplsPsSwitchCondition Integer32
  hwMplsPsWorkTunnelState Integer32
  hwMplsPsProtTunnelState Integer32
  hwMplsPsSwitchResult Integer32
  hwMplsPsCfgType Integer32
  hwMplsPsCfgProtectTunnId Integer32
  hwMplsPsCfgRevertiveMode Integer32
  hwMplsPsCfgWTR Integer32
  hwMplsPsCfgHoldOff Integer32
  hwMplsPsRowStatus RowStatus

HwMplsVCPsEntry  
SEQUENCE    
  hwMplsVCPsIfIndex InterfaceIndex
  hwMplsVCPsTNLBinding TruthValue
  hwMplsTeReverseLspName OCTET STRING
  hwMplsVcPsRowStatus RowStatus
  hwMplsTeReverseLspLsrId IpAddress
  hwMplsTeReverseLspTunnId Integer32

Defined Values

hwMplsOamPs 1.1.2011.5.12.7.1
OBJECT IDENTIFIER    

hwMplsPsObjects 1.1.2011.5.12.7.1.3
OBJECT IDENTIFIER    

hwMplsPsTable 1.1.2011.5.12.7.1.3.1
This table specifies per-protection-group MPLS PS capability and associated information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMplsPsEntry

hwMplsPsEntry 1.1.2011.5.12.7.1.3.1.1
An entry in this table is created by an LSR for every protection group capable of supporting mpls ps.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMplsPsEntry  

hwMplsPsIndex 1.1.2011.5.12.7.1.3.1.1.1
This is a unique index for an entry in the mplspsEntry.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hwMplsPsType 1.1.2011.5.12.7.1.3.1.1.2
The type of protection switch,can be 1:1,1+1,shared mesh, packet 1+1,the default choice is 1:1. In the 1+1 architecture type, a protection LSP is dedicated to each working LSP with the working LSP bridged onto the protection LSP at the source of the protection domain. The traffic on working and protection LSPs is transmitted simultaneously to the sink of the protection domain, where a selection between the working and protection LSP is made, based on some predetermined criteria, such as defect indication. In the 1:1 architecture type, a protection LSP is dedicated to each working LSP. The working traffic is transmitted either by working or protection LSP. In the shared mesh architecture type, possible sharing of protection capacity between disjoint link, node in the network is achieved while guaranteeing recovery from a single failure. In the packet 1+1 architecture type, the traffic is transmitted simultaneously onto two possibly disjoint routed LSPs to the sink of the protection domain. Each pair of duplicate transmitted packets is assigned the same identifier (sequence number) but distinct from the other pairs of duplicate packets. At the sink of the protection domain packet level selection mechanism is employed to select one of the two possibly received copies of each packet. 1: 1:1 protection switching,; 2: 1+1 protection switching; 3: shared mesh protection swiching; 4: packet 1+1 protection switching.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..4  

hwMplsPsWorkTunnName 1.1.2011.5.12.7.1.3.1.1.3
The name of work-tunnel.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hwMplsPsWorkTunnId 1.1.2011.5.12.7.1.3.1.1.4
Work-tunnel id(session-tunnel-id).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

hwMplsPsProtectTunnName 1.1.2011.5.12.7.1.3.1.1.5
The name of protect-tunnel.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hwMplsPsProtectTunnId 1.1.2011.5.12.7.1.3.1.1.6
Protect-tunnel id(session-tunnel-id).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

hwMplsPsRevertiveMode 1.1.2011.5.12.7.1.3.1.1.7
Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired.And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsWTR 1.1.2011.5.12.7.1.3.1.1.8
Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP,It prevents reversion back to select the working LSP until the Wait to Restore timer has expired.The default value is 12 minutes.step is 30s.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..60  

hwMplsPsHoldOff 1.1.2011.5.12.7.1.3.1.1.9
The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. step is 100ms.maximum is 10s.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..100  

hwMplsPsSwitchCondition 1.1.2011.5.12.7.1.3.1.1.10
The current switch condition of the protection group. 1: clear,This command clears all of the externally initiated switch commands listed below; 2: lockout of protection,Fix the selector position on the working LSP,Prevents the selector from switching to the protection LSP when it is selecting the working LSP. Switches the selector from the protection to the working LSP when it is selecting the protection LSP; 3: forced protection,Switches the selector from the working LSP to the protection LSP (unless a higher priority switch request (i.e., LoP) is in effect); 4: signal fail,for 1:1,Signal Fail (SF) is declared when the source of the protection domain enters the Defect State by receiving a BDI packet (from the return LSP or out of band). 5: manual switch for working-lsp,Switches the selector from the working LSP to the protection LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect); 6: manual switch for protection-lsp,Switches the selector from the protection LSP to the working LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect). 7: WTR-timer; 8: HoldOff-timer; 9: Others; The pripority of the commands are: clear > lockout of protection > force switch > manual switch for working lsp = manual switch for protection lsp
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..9  

hwMplsPsWorkTunnelState 1.1.2011.5.12.7.1.3.1.1.11
The state of working tunnel state in one protection group, whether it is in detection, 1: it is outof defect 2: it enters defect
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsProtTunnelState 1.1.2011.5.12.7.1.3.1.1.12
The state of protection tunnel state in one protection group, whether it is in detection, 1: it is outof defect 2: it enters defect
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsSwitchResult 1.1.2011.5.12.7.1.3.1.1.13
Which tunnel is used to transfer the data stream. 1: working-tunnel 2: protection-tunnel
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsCfgType 1.1.2011.5.12.7.1.3.1.1.14
The type of protection switch which is configured. 1: 1:1 2: 1+1 3: shared mesh 4: packet 1:1
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsCfgProtectTunnId 1.1.2011.5.12.7.1.3.1.1.15
Protect-tunnel id(session-tunnel-id).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..65535  

hwMplsPsCfgRevertiveMode 1.1.2011.5.12.7.1.3.1.1.16
Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired.And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsCfgWTR 1.1.2011.5.12.7.1.3.1.1.17
Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP,It prevents reversion back to select the working LSP until the Wait to Restore timer has expired.The default value is 12 minutes.step is 30s.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..60  

hwMplsPsCfgHoldOff 1.1.2011.5.12.7.1.3.1.1.18
The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. step is 100ms.maximum is 10s.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..100  

hwMplsPsRowStatus 1.1.2011.5.12.7.1.3.1.1.19
This variable is used to create, modify, and delete a row in this table. 1: active 2: not in service 3: not ready 4: create and go 5: create and wait 6: destroy
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

hwTunnPsTrapOpen 1.1.2011.5.12.7.1.3.2
1:enable; 2:disable;
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..2  

hwMplsVCPsTable 1.1.2011.5.12.7.1.3.3
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMplsVCPsEntry

hwMplsVCPsEntry 1.1.2011.5.12.7.1.3.3.1
this table for these commands 1.mpls te protection tunnel XXX 2. mpls te reverse-lsp { lsp-name XXXX | lsr-id X.X.X.X tunnel-id x } 3. mpls te reserved-for-binding
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMplsVCPsEntry  

hwMplsVCPsIfIndex 1.1.2011.5.12.7.1.3.3.1.1
Description.the index of working tunnel interface of Protection group
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

hwMplsVCPsTNLBinding 1.1.2011.5.12.7.1.3.3.1.2
Description.it is used by command ' mpls te reserved-for-binding '
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

hwMplsTeReverseLspName 1.1.2011.5.12.7.1.3.3.1.3
Description.it is used for command ' mpls te reverse-lsp lspname'
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hwMplsVcPsRowStatus 1.1.2011.5.12.7.1.3.3.1.4
Description. 1: active; 2: notInservice; 3: notReady; 4: CreateAndGo; 5: CreateAndWait; 6: destroy;
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMplsTeReverseLspLsrId 1.1.2011.5.12.7.1.3.3.1.5
Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX'
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hwMplsTeReverseLspTunnId 1.1.2011.5.12.7.1.3.3.1.6
Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX'
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..65535  

hwMplsPsNotifications 1.1.2011.5.12.7.1.4
OBJECT IDENTIFIER    

hwMplsPsSwitchPtoW 1.1.2011.5.12.7.1.4.1
This notification is generated when switching from protection-lsp to working-lsp occured.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsPsSwitchWtoP 1.1.2011.5.12.7.1.4.2
This notification is generated when switching from woking-lsp to protection-lsp occured.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsOamPsConformance 1.1.2011.5.12.7.1.100
OBJECT IDENTIFIER    

hwMplsOamPsCompliances 1.1.2011.5.12.7.1.100.1
OBJECT IDENTIFIER    

hwMplsOamPsGroupCompliance 1.1.2011.5.12.7.1.100.1.1
The compliance statement for mpls oam ps.
Status: current Access: read-create
MODULE-COMPLIANCE    

hwMplsOamPsGroups 1.1.2011.5.12.7.1.100.2
OBJECT IDENTIFIER    

hwMplsPsGroup 1.1.2011.5.12.7.1.100.2.1
The compliance statement for mpls oam ps management.
Status: current Access: read-create
OBJECT-GROUP    

hwMplsVcPsGroup 1.1.2011.5.12.7.1.100.2.2
The compliance statement for mpls oam ps reverse lsp.
Status: current Access: read-create
OBJECT-GROUP    

hwMplsPsNotificationGroup 1.1.2011.5.12.7.1.100.2.3
Description.
Status: current Access: read-create
NOTIFICATION-GROUP