HUAWEI-FR-QOS-MIB

File: HUAWEI-FR-QOS-MIB.mib (21196 bytes)

Imported modules

HUAWEI-MIB RFC1213-MIB SNMPv2-CONF
SNMPv2-SMI SNMPv2-TC

Imported symbols

hwDatacomm ifIndex OBJECT-GROUP
MODULE-COMPLIANCE IpAddress Integer32
Counter32 OBJECT-TYPE MODULE-IDENTITY
TEXTUAL-CONVENTION RowStatus DisplayString
MacAddress

Defined Types

DirectionType  
TEXTUAL-CONVENTION    
  current INTEGER inbound(1), outbound(2)

HwFrClassCfgInfoEntry  
SEQUENCE    
  hwFrClassIndex Integer32
  hwFrClassName STRING
  hwFrClassRowStatus RowStatus

HwCirAllowCfgInfoEntry  
SEQUENCE    
  hwCirAllowFrClassIndex Integer32
  hwCirAllowDirection Integer32
  hwCirAllowValue Integer32
  hwCirAllowRowStatus RowStatus

HwCirCfgInfoEntry  
SEQUENCE    
  hwCirFrClassIndex Integer32
  hwCirValue Integer32
  hwCirRowStatus RowStatus

HwIfApplyFrClassEntry  
SEQUENCE    
  hwIfApplyFrClassIfIndex Integer32
  hwIfApplyFrClassIndex Integer32
  hwIfApplyFrClassRowStatus RowStatus

HwPvcApplyFrClassEntry  
SEQUENCE    
  hwPvcApplyFrClassIfIndex Integer32
  hwPvcApplyFrClassDlciNum Integer32
  hwPvcApplyFrClassIndex Integer32
  hwPvcApplyFrClassRowStatus RowStatus

HwFrPvcBandwidthEntry  
SEQUENCE    
  hwFrPvcBandwidthMaxReservedBW Integer32
  hwFrPvcBandwidthAvailable Integer32

HwRTPFrClassApplyEntry  
SEQUENCE    
  hwRTPFrClassApplyFrClassIndex Integer32
  hwRTPFrClassApplyStartPort Integer32
  hwRTPFrClassApplyEndPort Integer32
  hwRTPFrClassApplyBandWidth Integer32
  hwRTPFrClassApplyCbs Integer32
  hwRTPFrClassApplyRowStatus RowStatus

HwRTPFrPvcQueueRunInfoEntry  
SEQUENCE    
  hwRTPFrPvcQueueSize Integer32
  hwRTPFrPvcQueueMaxSize Integer32
  hwRTPFrPvcQueueOutputs Counter32
  hwRTPFrPvcQueueDiscards Counter32

Defined Values

hwQoS 1.3.6.1.4.1.2011.5.25.32
OBJECT IDENTIFIER    

hwFrQoSMib 1.3.6.1.4.1.2011.5.25.32.3
The HUAWEI-FR-QOS-MIB contains objects to Manage configuration and Monitor running state for Class Based FR QoS feature. ********************************* MIB Tables ********************************** This MIB consists of the following tables: 1 : hwFrClassCfgInfoTable 2 : hwCirAllowCfgInfoTable 3 : hwCirCfgInfoTable 4 : hwIfApplyFrClassTable 5 : hwPvcApplyFrClassTable 6 : hwFrPvcBandwidthTable 7 : hwRTPFrClassApplyTable 8 : hwRTPFrPvcQueueRunInfoTable
MODULE-IDENTITY    

hwFrQoSObjects 1.3.6.1.4.1.2011.5.25.32.3.1
OBJECT IDENTIFIER    

hwFrClassObjects 1.3.6.1.4.1.2011.5.25.32.3.1.1
OBJECT IDENTIFIER    

hwFrClassIndexNext 1.3.6.1.4.1.2011.5.25.32.3.1.1.1
This object contains an appropriate value to be used for hwFrClassIndex when creating rows in the hwFrClassCfgInfoTable. Begin with 0.
OBJECT-TYPE    
  Integer32  

hwFrClassCfgInfoTable 1.3.6.1.4.1.2011.5.25.32.3.1.1.2
A table of Fr Class configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    HwFrClassCfgInfoEntry

hwFrClassCfgInfoEntry 1.3.6.1.4.1.2011.5.25.32.3.1.1.2.1
Fr Class Configuration Information Entry.
OBJECT-TYPE    
  HwFrClassCfgInfoEntry  

hwFrClassIndex 1.3.6.1.4.1.2011.5.25.32.3.1.1.2.1.1
Index of Fr Class. Begin with 0.
OBJECT-TYPE    
  Integer32  

hwFrClassName 1.3.6.1.4.1.2011.5.25.32.3.1.1.2.1.2
Name of Fr Class.
OBJECT-TYPE    
  STRING Size(1..31)  

hwFrClassRowStatus 1.3.6.1.4.1.2011.5.25.32.3.1.1.2.1.3
RowStatus. Three actions are used: active, createAndGo, destroy
OBJECT-TYPE    
  RowStatus  

hwCirAllowCfgInfoTable 1.3.6.1.4.1.2011.5.25.32.3.1.1.3
A table of DCE allowed rate Configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    HwCirAllowCfgInfoEntry

hwCirAllowCfgInfoEntry 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1
DCE allowed ratee Configuration Information Entry.
OBJECT-TYPE    
  HwCirAllowCfgInfoEntry  

hwCirAllowFrClassIndex 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1.1
Index of Fr Class. Begin with 0.Equal to hwFrClassIndex
OBJECT-TYPE    
  Integer32  

hwCirAllowDirection 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1.2
Packet Direction. value 1,2,3 Used by hwCirAllowValue. inbound (1) outbound (2) inbound and outbound (3)
OBJECT-TYPE    
  Integer32  

hwCirAllowValue 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1.3
DCE allowed rate (value greater than CIR) Unit : Bits per second. Value : <1-45000000> .
OBJECT-TYPE    
  Integer32 1..45000000  

hwCirAllowRowStatus 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1.4
RowStatus. Three actions are used: active, createAndGo, destroy
OBJECT-TYPE    
  RowStatus  

hwCirCfgInfoTable 1.3.6.1.4.1.2011.5.25.32.3.1.1.4
A table of Committed Information Rate Configuration information.
OBJECT-TYPE    
  SEQUENCE OF  
    HwCirCfgInfoEntry

hwCirCfgInfoEntry 1.3.6.1.4.1.2011.5.25.32.3.1.1.4.1
Committed Information Rate Configuration Information Entry.
OBJECT-TYPE    
  HwCirCfgInfoEntry  

hwCirFrClassIndex 1.3.6.1.4.1.2011.5.25.32.3.1.1.4.1.1
Index of Fr Class. Begin with 0.Equal to hwFrClassIndex
OBJECT-TYPE    
  Integer32  

hwCirValue 1.3.6.1.4.1.2011.5.25.32.3.1.1.4.1.2
CIR in packet output direction ,bps. Value : <1000-45000000>.
OBJECT-TYPE    
  Integer32 1000..45000000  

hwCirRowStatus 1.3.6.1.4.1.2011.5.25.32.3.1.1.4.1.3
RowStatus. Three actions are used: active, createAndGo, destroy
OBJECT-TYPE    
  RowStatus  

hwIfApplyFrClassTable 1.3.6.1.4.1.2011.5.25.32.3.1.1.5
A table of QoS Fr Class instance.
OBJECT-TYPE    
  SEQUENCE OF  
    HwIfApplyFrClassEntry

hwIfApplyFrClassEntry 1.3.6.1.4.1.2011.5.25.32.3.1.1.5.1
FrClass applied on interface Configuration Information Entry.
OBJECT-TYPE    
  HwIfApplyFrClassEntry  

hwIfApplyFrClassIfIndex 1.3.6.1.4.1.2011.5.25.32.3.1.1.5.1.1
Interface Index, equal to ifIndex.
OBJECT-TYPE    
  Integer32  

hwIfApplyFrClassIndex 1.3.6.1.4.1.2011.5.25.32.3.1.1.5.1.2
Index of Fr Class, equal to hwFrClassIndex
OBJECT-TYPE    
  Integer32  

hwIfApplyFrClassRowStatus 1.3.6.1.4.1.2011.5.25.32.3.1.1.5.1.3
RowStatus. Three actions are used: active, createAndGo, destroy
OBJECT-TYPE    
  RowStatus  

hwPvcApplyFrClassTable 1.3.6.1.4.1.2011.5.25.32.3.1.1.6
A table of QoS Fr Class instance.
OBJECT-TYPE    
  SEQUENCE OF  
    HwPvcApplyFrClassEntry

hwPvcApplyFrClassEntry 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1
Fr Class applied on FR Pvc Configuration Information Entry.
OBJECT-TYPE    
  HwPvcApplyFrClassEntry  

hwPvcApplyFrClassIfIndex 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1.1
Fr Interface Index, equal to ifIndex.
OBJECT-TYPE    
  Integer32  

hwPvcApplyFrClassDlciNum 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1.2
Fr DLCI number.
OBJECT-TYPE    
  Integer32 16..1007  

hwPvcApplyFrClassIndex 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1.3
Index of Fr Class, equal to hwFrClassIndex
OBJECT-TYPE    
  Integer32  

hwPvcApplyFrClassRowStatus 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1.4
RowStatus. Three actions are used: active, createAndGo, destroy
OBJECT-TYPE    
  RowStatus  

hwFrPvcBandwidthTable 1.3.6.1.4.1.2011.5.25.32.3.1.1.7
A table of Running statistics for bandwidth.
OBJECT-TYPE    
  SEQUENCE OF  
    HwFrPvcBandwidthEntry

hwFrPvcBandwidthEntry 1.3.6.1.4.1.2011.5.25.32.3.1.1.7.1
Bandwidth Running statistics
OBJECT-TYPE    
  HwFrPvcBandwidthEntry  

hwFrPvcBandwidthMaxReservedBW 1.3.6.1.4.1.2011.5.25.32.3.1.1.7.1.1
Max reserved bandWidth. Unit : Kbps
OBJECT-TYPE    
  Integer32  

hwFrPvcBandwidthAvailable 1.3.6.1.4.1.2011.5.25.32.3.1.1.7.1.2
Available bandWidth. Unit : Kbps
OBJECT-TYPE    
  Integer32  

hwRTPQoSObjects 1.3.6.1.4.1.2011.5.25.32.3.1.2
OBJECT IDENTIFIER    

hwRTPFrClassApplyTable 1.3.6.1.4.1.2011.5.25.32.3.1.2.1
A table of QoS rtpq instance.
OBJECT-TYPE    
  SEQUENCE OF  
    HwRTPFrClassApplyEntry

hwRTPFrClassApplyEntry 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1
Rtpq Configuration Information Entry.
OBJECT-TYPE    
  HwRTPFrClassApplyEntry  

hwRTPFrClassApplyFrClassIndex 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.1
Fr Class Index, equal to HwFrClassIndex.
OBJECT-TYPE    
  Integer32  

hwRTPFrClassApplyStartPort 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.2
RTP-PORT(3): start-port: 2000~65535
OBJECT-TYPE    
  Integer32 2000..65535  

hwRTPFrClassApplyEndPort 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.3
RTP-PORT(3): end-port: 2000~65535
OBJECT-TYPE    
  Integer32 2000..65535  

hwRTPFrClassApplyBandWidth 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.4
Max bandWidth Value: Absolute value: 8~1000000. Unit: Kbps
OBJECT-TYPE    
  Integer32 8..1000000  

hwRTPFrClassApplyCbs 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.5
Committed Burst Size: 1500~2000000. Unit: byte
OBJECT-TYPE    
  Integer32 1500..2000000  

hwRTPFrClassApplyRowStatus 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.6
RowStatus for RTPFrClassApply Table. Three actions are used: active, createAndGo, destroy
OBJECT-TYPE    
  RowStatus  

hwRTPFrPvcQueueRunInfoTable 1.3.6.1.4.1.2011.5.25.32.3.1.2.2
A table of Running statistics for RTPQ Queue applied on the FR PVC
OBJECT-TYPE    
  SEQUENCE OF  
    HwRTPFrPvcQueueRunInfoEntry

hwRTPFrPvcQueueRunInfoEntry 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1
Queue statistics entry.
OBJECT-TYPE    
  HwRTPFrPvcQueueRunInfoEntry  

hwRTPFrPvcQueueSize 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1.1
Size of Rtpq Queue.
OBJECT-TYPE    
  Integer32  

hwRTPFrPvcQueueMaxSize 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1.2
Max size of Rtpq Queue.
OBJECT-TYPE    
  Integer32  

hwRTPFrPvcQueueOutputs 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1.3
Outputs of Rtpq Queue.
OBJECT-TYPE    
  Counter32  

hwRTPFrPvcQueueDiscards 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1.4
Discards of Rtpq Queue.
OBJECT-TYPE    
  Counter32