HUAWEI-FCOE-MIB

File: HUAWEI-FCOE-MIB.mib (12915 bytes)

Imported modules

SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-TC
SNMPv2-SMI HUAWEI-MIB

Imported symbols

SnmpAdminString OBJECT-GROUP MODULE-COMPLIANCE
NOTIFICATION-GROUP DisplayString RowStatus
TEXTUAL-CONVENTION TimeTicks Integer32
Unsigned32 IpAddress Counter32
Counter64 OBJECT-TYPE MODULE-IDENTITY
NOTIFICATION-TYPE hwDatacomm

Defined Types

HWResetFlag  
Reset Flag: DISABLE (0) RESET (1) ENABLE (2)
TEXTUAL-CONVENTION    
  INTEGER disable(0), reset(1), enable(2)  

HWCosType  
BE(1) AF1(2) AF2(3) AF3(4) AF4(5) EF(6) CS6(7) CS7(8)
TEXTUAL-CONVENTION    
  INTEGER be(1), af1(2), af2(3), af3(4), af4(5), ef(6), cs6(7), cs7(8)  

HwDcbPfcFrameStatisticsEntry  
SEQUENCE    
  hwDcbPfcIfIndex Integer32
  hwDcbPfcQueueID HWCosType
  hwDcbPfcRxFrames Counter64
  hwDcbPfcTxFrames Counter64
  hwDcbPfcResetFlag HWResetFlag

Defined Values

hwFCoEMIB 1.3.6.1.4.1.2011.5.25.303
The MIB contains objects of DC FCOE features .
MODULE-IDENTITY    

hwFCoEMIBTrapObjects 1.3.6.1.4.1.2011.5.25.303.1
OBJECT IDENTIFIER    

hwFCoEIfName 1.3.6.1.4.1.2011.5.25.303.1.1
This FCoE interface name is sent from device.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING  

hwFCoEVlan 1.3.6.1.4.1.2011.5.25.303.1.2
This VLAN is sent from device.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwFCoEPortResource 1.3.6.1.4.1.2011.5.25.303.1.3
This FCoE port resource is reach max limit.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwTNPortVlan 1.3.6.1.4.1.2011.5.25.303.1.4
The detect vlan is different from the configued vlan.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwFCoEFcfVlan 1.3.6.1.4.1.2011.5.25.303.1.5
The Fcf vlan is different from the configued vlan.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwFCoEVFPortNum 1.3.6.1.4.1.2011.5.25.303.1.6
The FCoE VF Port number.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwFCoEVNPortNum 1.3.6.1.4.1.2011.5.25.303.1.7
The FCoE VN Port number.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwFCoEInstName 1.3.6.1.4.1.2011.5.25.303.1.8
The FCoe instance name.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING  

hwSysMacNum 1.3.6.1.4.1.2011.5.25.303.1.9
The system mac-address number.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwFCoEVsId 1.3.6.1.4.1.2011.5.25.303.1.10
The Fcoe-port Index.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwFCoEMIBTraps 1.3.6.1.4.1.2011.5.25.303.2
OBJECT IDENTIFIER    

hwFCoEPortLoseVlan 1.3.6.1.4.1.2011.5.25.303.2.1
When the device receives a FIP Notification packet,it gets VLANs from the packet, and compares with configuration at the inputing-port, if it's not same, exports warning.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwFCoEVLanError 1.3.6.1.4.1.2011.5.25.303.2.2
When the device receives a FIP Notification packet,it gets VLANs from the packet, and lookup at the configuration , if it's not exist, exports warning.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwFCoEConnectVfNum 1.3.6.1.4.1.2011.5.25.303.2.3
The number of vf-port has reached max limits 64.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwFCoELoginVnNum 1.3.6.1.4.1.2011.5.25.303.2.4
The number of online vn-ports has reached max limits 256.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwFCoETnNum 1.3.6.1.4.1.2011.5.25.303.2.5
The number of VN_Ports that belong to the same NPV instance exceeds the number of MAC addresses.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwFCoETnPortVlan 1.3.6.1.4.1.2011.5.25.303.2.6
The requested vlan is different from the configued NPV vlan.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwFCoEConformance 1.3.6.1.4.1.2011.5.25.303.3
OBJECT IDENTIFIER    

hwFCoECompliances 1.3.6.1.4.1.2011.5.25.303.3.1
OBJECT IDENTIFIER    

hwFCoECompliance 1.3.6.1.4.1.2011.5.25.303.3.1.1
The compliance statement for SNMP entities which implement the HUAWEI-FCOE-MIB.
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE    

hwFCoEGroups 1.3.6.1.4.1.2011.5.25.303.3.2
OBJECT IDENTIFIER    

hwFCoEMIBTrapObjectGroup 1.3.6.1.4.1.2011.5.25.303.3.2.1
Group for FCoE trap objects.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

hwFCoEMIBTrapGroup 1.3.6.1.4.1.2011.5.25.303.3.2.2
Group for FCoE trap.
Status: current Access: accessible-for-notify
NOTIFICATION-GROUP    

hwDcbPfcFrameGroup 1.3.6.1.4.1.2011.5.25.303.3.2.3
Group for dcb pfc frame statistics.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

hwDcbPfcFrameStatisticsObjects 1.3.6.1.4.1.2011.5.25.303.4
OBJECT IDENTIFIER    

hwDcbPfcFrameStatisticsTable 1.3.6.1.4.1.2011.5.25.303.4.1
A table of dcb pfc frame statistics for queue on the interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwDcbPfcFrameStatisticsEntry

hwDcbPfcFrameStatisticsEntry 1.3.6.1.4.1.2011.5.25.303.4.1.1
dcb pfc frame statistics entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwDcbPfcFrameStatisticsEntry  

hwDcbPfcIfIndex 1.3.6.1.4.1.2011.5.25.303.4.1.1.1
The value of this object identifies the interface index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwDcbPfcQueueID 1.3.6.1.4.1.2011.5.25.303.4.1.1.2
The value of this object identifies the queue index.
Status: current Access: read-only
OBJECT-TYPE    
  HWCosType  

hwDcbPfcRxFrames 1.3.6.1.4.1.2011.5.25.303.4.1.1.3
This object indicates the number of pfc frames received by the queue.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

hwDcbPfcTxFrames 1.3.6.1.4.1.2011.5.25.303.4.1.1.4
This object indicates the number of pfc frames sent by the queue.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

hwDcbPfcResetFlag 1.3.6.1.4.1.2011.5.25.303.4.1.1.5
Reset dcb pfc frame statistics information.
Status: current Access: read-write
OBJECT-TYPE    
  HWResetFlag