HUAWEI-ENTITY-TRAP-MIB
File:
HUAWEI-ENTITY-TRAP-MIB.mib (65934 bytes)
Imported modules
Imported symbols
Defined Types
HwEntityThresholdEntry |
|
SEQUENCE |
|
|
|
|
hwEntityThresholdType |
INTEGER |
|
|
hwEntityThresholdValue |
Integer32 |
|
|
hwEntityThresholdCurrent |
Integer32 |
|
|
hwEntityThresholdCritical |
Integer32 |
|
|
hwEntityThresholdWarning |
Integer32 |
|
Defined Values
hwEntityTrapMIB |
1.3.6.1.4.1.2011.5.25.219 |
This is the base trap definition for DataCom. |
MODULE-IDENTITY |
|
|
|
hwEntityTrapEntType |
1.3.6.1.4.1.2011.5.25.219.1.2 |
The entity type. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
mpu(1), lpu(2), sfu(3), pic(4), cfcard(5), ofc(6) |
|
hwEntityCommunicateType |
1.3.6.1.4.1.2011.5.25.219.1.4 |
The communicate type. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
controlChannel(1), monitorChannel(2), clockChannel(3), dataChannel(4) |
|
hwEntityThresholdEntry |
1.3.6.1.4.1.2011.5.25.219.1.5.1 |
The entry of threshold table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HwEntityThresholdEntry |
|
|
hwEntityThresholdType |
1.3.6.1.4.1.2011.5.25.219.1.5.1.1 |
The abnormal type for temperature, voltage, humidity...... |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
riseOver(1), fallBelow(2) |
|
hwEntityThresholdValue |
1.3.6.1.4.1.2011.5.25.219.1.5.1.2 |
The threshold value of temperature, humidity ,fog ...... |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntityThresholdCritical |
1.3.6.1.4.1.2011.5.25.219.1.5.1.4 |
The critical alarm threshold for critical alarm. It could be used
for a more dangerous instance than hwEntityThresholdCritical. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntityThresholdWarning |
1.3.6.1.4.1.2011.5.25.219.1.5.1.5 |
The warning alarm threshold for warning alarm. It could be used
for a more dangerous instance than hwEntityThresholdWarning. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwUserDefAlarmName |
1.3.6.1.4.1.2011.5.25.219.1.6 |
Description. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hwSoftwareVersion |
1.3.6.1.4.1.2011.5.25.219.1.8 |
Description. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hwStartupSoftwareFileName |
1.3.6.1.4.1.2011.5.25.219.1.9 |
Description. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hwStorageDevName |
1.3.6.1.4.1.2011.5.25.219.1.10 |
Description. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hwPortDownReason |
1.3.6.1.4.1.2011.5.25.219.1.11 |
AUAIS: The RX detects administrative(A) unit(U) alarm(A) indication(I) signal(S).
B1TCA: The RX detects b1(B1) threshold(T) crossing(C) alarm(A).
B2TCA: The RX detects b2(B2) threshold(T) crossing(C) alarm(A).
B3TCA: The RX detects b3(B3) threshold(T) crossing(C) alarm(A).
LAIS: The RX detects line(L) alarm(A) indication(I) signal(S).
LCD: The RX detects loss(L) of code-group(C) delineation(D).
LOF: The RX detects loss(L) of(O) frame(F).
LOM: The RX detects loss(L) of(O) multiframe(M).
LOP: The RX detects loss(L) of(O) pointer(M).
LOS: The RX detects loss(L) of(O) signal(S).
LRDI: The RX detects line(L) remote(R) defect(D) indication(I).
LREI: The RX detects line(L) remote(R) error(D) indication(I).
OOF: The RX detects out(O) of(O) frame(F).
PAIS: The RX detects path(P) alarm(A) indication(I) signal(S).
PPLM: The RX detects path(P) payload(P) label(L) mismatch(M).
PRDI: The RX detects path(P) remote(R) defect(D) indication(I).
PREI: The RX detects path(P) remote(R) error(E) indication(I).
PUNEQ: The RX detects path(P) unequipped(UNEQ).
RDOOL: The RX detects receive(R) data(D) out(O) of(O) lock(L).
RROOL: The RX detects receive(R) reference(R) out(O) of(O) lock(L).
SD: The RX detects signal(S) degrade(D).
SF: The RX detects signal(S) fail(F).
TROOL: The TX detects transmit(T) reference(R) out(O) of(O) lock(L).
WLINK: The RX detects pcs link has failed (wis mode).
TRANSCEIVER_OFFLINE: The transceiver is not in position.
TRANSCEIVER_FAIL: A hardware failure occurs when accessing the transceiver.
TRANSCEIVER_MISMATCH: The transceiver does not match the port-mode.
TRANSCEIVER_UNKNOWN: The transceiver is unknown type.
PMA_LOS: The PMA(physical medium attachment) detects loss of signal.
PMA_UNLOCK: The PMA(physical medium attachment) detects receive data out of lock.
PCS_HIGHBER: The PCS(physical coding sublayer) enter High-BER status.
PCS_UNLOCK: The PCS(physical coding sublayer) detects receive data out of lock.
LOCAL_FAULT: The RX detects Local Fault signal.
REMOTE_FAULT: The RX detects Remote Fault signal.
NEGOTIATION_FAIL: Auto-negotiation is not successful.
SOFT_FORCE_DOWN: The interface was DOWN triggered by a protocol module or was administratively shut down.
GPON_ACTIVATE_FAIL: The GPON optical module failed to be detected or activated.
GPON_AUTHEN_LOID_FAIL: The authentication failed because the GPON optical module does not have an LOID.
GPON_AUTHEN_PASSWORD_FAIL: The authentication failed because the password is incorrect.
GPON_AUTHEN_LOIDCOLLI_FAIL: The authentication failed due to LODI collision of GPON optical modules.
GPON_FIBER_LINKFAULT_FAIL: The optical link failed due to link disconnection or low optical receive power.
GPON_TRANSCEIVERSHUT_FAIL: The transmitter of the GPON optical module was turned off on the OLT.
GPON_ABNORMALSHINE_FAIL: The GPON optical module detected light emitting abnormalities, and the transmitter was turned off.
GPON_TRANSCEIVERABNORMAL: Laser is in fault state.
GPON_OTHER_ALARM: The GPON optical module has other fault. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hwEntityTrapReasonDescr |
1.3.6.1.4.1.2011.5.25.219.1.13 |
Description of trap reason. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hwUsbOperType |
1.3.6.1.4.1.2011.5.25.219.1.14 |
The staus of usb card. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwChassisRemove |
1.3.6.1.4.1.2011.5.25.219.2.1.1 |
Chassis has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwChassisInsert |
1.3.6.1.4.1.2011.5.25.219.2.1.2 |
Chassis has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwChassisFail |
1.3.6.1.4.1.2011.5.25.219.2.1.3 |
Chassis become failure for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwChassisFailResume |
1.3.6.1.4.1.2011.5.25.219.2.1.4 |
Board resume from failure. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwChassisInvalid |
1.3.6.1.4.1.2011.5.25.219.2.1.5 |
Chassis is invalid for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwChassisInvalidResume |
1.3.6.1.4.1.2011.5.25.219.2.1.6 |
Chassis resume from invalid situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBoardTrap |
1.3.6.1.4.1.2011.5.25.219.2.2 |
OBJECT IDENTIFIER |
|
|
|
hwBoardRemove |
1.3.6.1.4.1.2011.5.25.219.2.2.1 |
Board has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBoardInsert |
1.3.6.1.4.1.2011.5.25.219.2.2.2 |
Board has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBoardFail |
1.3.6.1.4.1.2011.5.25.219.2.2.3 |
Board become failure for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBoardFailResume |
1.3.6.1.4.1.2011.5.25.219.2.2.4 |
Board resume from failure. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBoardInvalid |
1.3.6.1.4.1.2011.5.25.219.2.2.5 |
Board is invalid for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBoardInvalidResume |
1.3.6.1.4.1.2011.5.25.219.2.2.6 |
Board resume from invalid situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBoardLeaveMaster |
1.3.6.1.4.1.2011.5.25.219.2.2.7 |
MPU leave master role. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBoardBecomeMaster |
1.3.6.1.4.1.2011.5.25.219.2.2.8 |
MPU become master role. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUpMicroSwitchOpen |
1.3.6.1.4.1.2011.5.25.219.2.2.9 |
Up micro switch open. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUpMicroSwitchClose |
1.3.6.1.4.1.2011.5.25.219.2.2.10 |
Up micro switch close. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwDownMicroSwitchOpen |
1.3.6.1.4.1.2011.5.25.219.2.2.11 |
Down micro switch open. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwDownMicroSwitchClose |
1.3.6.1.4.1.2011.5.25.219.2.2.12 |
Down micro switch close. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBoardPowerOff |
1.3.6.1.4.1.2011.5.25.219.2.2.13 |
The LPU is powered off, because this LPU only supports the trunks with index 127 or smaller than 127. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBandwidthOfAllCardsExceedsThreshold |
1.3.6.1.4.1.2011.5.25.219.2.2.14 |
The total bandwidth of all cards exceeds the forwarding capacity of system control board. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCardTrap |
1.3.6.1.4.1.2011.5.25.219.2.3 |
OBJECT IDENTIFIER |
|
|
|
hwCardRemove |
1.3.6.1.4.1.2011.5.25.219.2.3.1 |
Card has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCardInsert |
1.3.6.1.4.1.2011.5.25.219.2.3.2 |
Card has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCardFail |
1.3.6.1.4.1.2011.5.25.219.2.3.3 |
Card become failure for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCardFailResume |
1.3.6.1.4.1.2011.5.25.219.2.3.4 |
Card resume from failure. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCardInvalid |
1.3.6.1.4.1.2011.5.25.219.2.3.5 |
Card is invalid for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCardInvalidResume |
1.3.6.1.4.1.2011.5.25.219.2.3.6 |
Card resume from invalid situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalRemove |
1.3.6.1.4.1.2011.5.25.219.2.4.1 |
Optical Module has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalInsert |
1.3.6.1.4.1.2011.5.25.219.2.4.2 |
Optical Module has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalFail |
1.3.6.1.4.1.2011.5.25.219.2.4.3 |
Optical Module become failure for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalFailResume |
1.3.6.1.4.1.2011.5.25.219.2.4.4 |
Optical Module resume from failure. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalInvalid |
1.3.6.1.4.1.2011.5.25.219.2.4.5 |
Optical Module is invalid for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalInvalidResume |
1.3.6.1.4.1.2011.5.25.219.2.4.6 |
Optical Module resume from invalid situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalPowerAlarm |
1.3.6.1.4.1.2011.5.25.219.2.4.7 |
Temperature rise over or fall below the warning alarm threshold.
Only indicate the temperature of board,card or optical module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalPowerAlarmResume |
1.3.6.1.4.1.2011.5.25.219.2.4.8 |
Temperature rise over or fall below the warning alarm threshold.
Only indicate the temperature of board,card or optical module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalUnAuthorized |
1.3.6.1.4.1.2011.5.25.219.2.4.9 |
The optical module authentication alarm occured. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalUnAuthorizedResume |
1.3.6.1.4.1.2011.5.25.219.2.4.10 |
The optical module authentication alarm resumed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwLaserNoFited |
1.3.6.1.4.1.2011.5.25.219.2.4.11 |
The laser not installed alarm occured. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwLaserNoFitedResume |
1.3.6.1.4.1.2011.5.25.219.2.4.12 |
The laser not installed alarm resumed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalTunableNotMatch |
1.3.6.1.4.1.2011.5.25.219.2.4.13 |
Configuration collision occurred between wavelength setting and untunable optical module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwOpticalTunableNotMatchResume |
1.3.6.1.4.1.2011.5.25.219.2.4.14 |
Configuration collision removed between wavelength setting and untunable optical module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerTrap |
1.3.6.1.4.1.2011.5.25.219.2.5 |
OBJECT IDENTIFIER |
|
|
|
hwPowerRemove |
1.3.6.1.4.1.2011.5.25.219.2.5.1 |
Power has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerInsert |
1.3.6.1.4.1.2011.5.25.219.2.5.2 |
Power has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerFail |
1.3.6.1.4.1.2011.5.25.219.2.5.3 |
Power become failure for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerFailResume |
1.3.6.1.4.1.2011.5.25.219.2.5.4 |
Power resume from failure. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerInvalid |
1.3.6.1.4.1.2011.5.25.219.2.5.5 |
Power is invalid for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerInvalidResume |
1.3.6.1.4.1.2011.5.25.219.2.5.6 |
Power resume from invalid situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerUnusable |
1.3.6.1.4.1.2011.5.25.219.2.5.7 |
Power change to unusable status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerUnusableResume |
1.3.6.1.4.1.2011.5.25.219.2.5.8 |
Power change to usable status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFanTrap |
1.3.6.1.4.1.2011.5.25.219.2.6 |
OBJECT IDENTIFIER |
|
|
|
hwFanRemove |
1.3.6.1.4.1.2011.5.25.219.2.6.1 |
Fan has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFanInsert |
1.3.6.1.4.1.2011.5.25.219.2.6.2 |
Fan has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFanFail |
1.3.6.1.4.1.2011.5.25.219.2.6.3 |
Fan become failure for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFanFailResume |
1.3.6.1.4.1.2011.5.25.219.2.6.4 |
Fan resume from failure. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFanInvalid |
1.3.6.1.4.1.2011.5.25.219.2.6.5 |
Fan is invalid for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFanInvalidResume |
1.3.6.1.4.1.2011.5.25.219.2.6.6 |
Fan resume from invalid situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFanUnusable |
1.3.6.1.4.1.2011.5.25.219.2.6.7 |
Fan change to unusable status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFanUnusableResume |
1.3.6.1.4.1.2011.5.25.219.2.6.8 |
Fan change to usable status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwLcdTrap |
1.3.6.1.4.1.2011.5.25.219.2.7 |
OBJECT IDENTIFIER |
|
|
|
hwLcdRemove |
1.3.6.1.4.1.2011.5.25.219.2.7.1 |
Lcd has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwLcdInsert |
1.3.6.1.4.1.2011.5.25.219.2.7.2 |
Lcd has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwLcdInvalid |
1.3.6.1.4.1.2011.5.25.219.2.7.3 |
Lcd is invalid for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwLcdInvalidResume |
1.3.6.1.4.1.2011.5.25.219.2.7.4 |
Lcd resume from invalid situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwLcdUnusable |
1.3.6.1.4.1.2011.5.25.219.2.7.5 |
Lcd change to unusable status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwLcdUnusableResume |
1.3.6.1.4.1.2011.5.25.219.2.7.6 |
Lcd change to usable status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCmuTrap |
1.3.6.1.4.1.2011.5.25.219.2.8 |
OBJECT IDENTIFIER |
|
|
|
hwCmuRemove |
1.3.6.1.4.1.2011.5.25.219.2.8.1 |
Cmu has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCmuInsert |
1.3.6.1.4.1.2011.5.25.219.2.8.2 |
Cmu has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCmuInvalid |
1.3.6.1.4.1.2011.5.25.219.2.8.3 |
Cmu is invalid for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCmuInvalidResume |
1.3.6.1.4.1.2011.5.25.219.2.8.4 |
Cmu reusme from invalid situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCmuUnusable |
1.3.6.1.4.1.2011.5.25.219.2.8.5 |
Cmu change to unusable status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCmuUnusableResume |
1.3.6.1.4.1.2011.5.25.219.2.8.6 |
Cmu change to usable status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCommunicateError |
1.3.6.1.4.1.2011.5.25.219.2.9.1 |
Communication error has been detected. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCommunicateResume |
1.3.6.1.4.1.2011.5.25.219.2.9.2 |
Resume from communication error situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwTempAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.1 |
Temperature rise over or fall below the alarm threshold. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwTempResume |
1.3.6.1.4.1.2011.5.25.219.2.10.2 |
Temperature back to normal level. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwHumidityAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.3 |
Humidity rise over or fall below the alarm threshold. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwHumidityResume |
1.3.6.1.4.1.2011.5.25.219.2.10.4 |
Humidity back to normal level. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwVoltAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.5 |
Voltage of power rise over or fall below the alarm threshold. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwVoltResume |
1.3.6.1.4.1.2011.5.25.219.2.10.6 |
Voltage back to normal level. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwGateAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.7 |
Gate switch to the alarm status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwGateResume |
1.3.6.1.4.1.2011.5.25.219.2.10.8 |
Gate switch to normal status. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFogAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.9 |
Fog rise over alarm threshold. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFogResume |
1.3.6.1.4.1.2011.5.25.219.2.10.10 |
Fog back to normal level. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUnstableAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.11 |
Entity has been inserted but position unstable. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUnstableResume |
1.3.6.1.4.1.2011.5.25.219.2.10.12 |
Resume from entity position unstable situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBrdTempAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.13 |
Temperature rise over or fall below the warning alarm threshold.
Only indicate the temperature of board,card or optical module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBrdTempResume |
1.3.6.1.4.1.2011.5.25.219.2.10.14 |
Temperature back to normal level.
Only indicate the temperature of board,card or optical module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBrdTempFatalAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.15 |
Temperature rise over or fall below the critical alarm threshold.
Only indicate the temperature of board,card or optical module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBrdTempFatalResume |
1.3.6.1.4.1.2011.5.25.219.2.10.16 |
Temperature back to normal level.
Only indicate the temperature of board,card or optical module. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerFailureAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.17 |
Power supply failed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPowerFailureResume |
1.3.6.1.4.1.2011.5.25.219.2.10.18 |
Power supply resumed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwIOSwitchOneAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.19 |
The IO-alarm 1 arise. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwIOSwitchOneAlarmResume |
1.3.6.1.4.1.2011.5.25.219.2.10.20 |
The IO-alarm 1 resumed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwIOSwitchTwoAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.21 |
The IO-alarm 2 arise. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwIOSwitchTwoAlarmResume |
1.3.6.1.4.1.2011.5.25.219.2.10.22 |
The IO-alarm 2 resumed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwIOSwitchThreeAlarm |
1.3.6.1.4.1.2011.5.25.219.2.10.23 |
The IO-alarm 3 arise. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwIOSwitchThreeAlarmResume |
1.3.6.1.4.1.2011.5.25.219.2.10.24 |
The IO-alarm 3 resumed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwEntityDyingGaspEvent |
1.3.6.1.4.1.2011.5.25.219.2.10.25 |
Power supply failed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwSystemConfigError |
1.3.6.1.4.1.2011.5.25.219.2.11.1 |
System configuration error has been detected. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwSystemConfigResume |
1.3.6.1.4.1.2011.5.25.219.2.11.2 |
Resume from system configuration error situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwSystemRollback |
1.3.6.1.4.1.2011.5.25.219.2.11.3 |
System configuration error has been detected. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPortTrap |
1.3.6.1.4.1.2011.5.25.219.2.12 |
OBJECT IDENTIFIER |
|
|
|
hwPortDown |
1.3.6.1.4.1.2011.5.25.219.2.12.1 |
One of the port physical connect down. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPortUp |
1.3.6.1.4.1.2011.5.25.219.2.12.2 |
One of the port physical connect up. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPortNoSupportOETrap |
1.3.6.1.4.1.2011.5.25.219.2.12.3 |
one of the stack port does not support the insertion of the O/E converter. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUserDefAlarm |
1.3.6.1.4.1.2011.5.25.219.2.13.1 |
User defined alarm has been detected. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUserDefResume |
1.3.6.1.4.1.2011.5.25.219.2.13.2 |
Resume from User defined alarm. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCPUTrap |
1.3.6.1.4.1.2011.5.25.219.2.14 |
OBJECT IDENTIFIER |
|
|
|
hwCPUUtilizationRising |
1.3.6.1.4.1.2011.5.25.219.2.14.1 |
CPU utilization overrun. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwCPUUtilizationResume |
1.3.6.1.4.1.2011.5.25.219.2.14.2 |
CPU utilization back to normal level |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwMemoryTrap |
1.3.6.1.4.1.2011.5.25.219.2.15 |
OBJECT IDENTIFIER |
|
|
|
hwMemUtilizationRising |
1.3.6.1.4.1.2011.5.25.219.2.15.1 |
Memory utilization overrun. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwMemUtilizationResume |
1.3.6.1.4.1.2011.5.25.219.2.15.2 |
Memory utilization back to normal level |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwStorageDevRemove |
1.3.6.1.4.1.2011.5.25.219.2.16.1 |
Memory utilization overrun. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwStorageDevInsert |
1.3.6.1.4.1.2011.5.25.219.2.16.2 |
Memory utilization back to normal level |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPppTrap |
1.3.6.1.4.1.2011.5.25.219.2.17 |
OBJECT IDENTIFIER |
|
|
|
hwPppLoopbackDetect |
1.3.6.1.4.1.2011.5.25.219.2.17.1 |
The interface Loopback is detected. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPppLoopbackDetResume |
1.3.6.1.4.1.2011.5.25.219.2.17.2 |
The interface is recovered from Loopback. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFileError |
1.3.6.1.4.1.2011.5.25.219.2.18.1 |
Memory utilization overrun. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwFileErrorResume |
1.3.6.1.4.1.2011.5.25.219.2.18.2 |
Memory utilization back to normal level |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUSBTrap |
1.3.6.1.4.1.2011.5.25.219.2.19 |
OBJECT IDENTIFIER |
|
|
|
hwUSBInsert |
1.3.6.1.4.1.2011.5.25.219.2.19.1 |
The USB device has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUSBRemove |
1.3.6.1.4.1.2011.5.25.219.2.19.2 |
The USB device has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUSBUnidentified |
1.3.6.1.4.1.2011.5.25.219.2.19.3 |
The USB device is unidentified. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUSBUnidentifiedResume |
1.3.6.1.4.1.2011.5.25.219.2.19.4 |
The USB device resume from unidentified situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwUsbStatusChg |
1.3.6.1.4.1.2011.5.25.219.2.19.5 |
The USB device status has been changed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPmuTrap |
1.3.6.1.4.1.2011.5.25.219.2.20 |
OBJECT IDENTIFIER |
|
|
|
hwPmuRemove |
1.3.6.1.4.1.2011.5.25.219.2.20.1 |
Pmu has been removed. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPmuInsert |
1.3.6.1.4.1.2011.5.25.219.2.20.2 |
Pmu has been inserted. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPmuFail |
1.3.6.1.4.1.2011.5.25.219.2.20.3 |
Pmu become failure for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPmuFailResume |
1.3.6.1.4.1.2011.5.25.219.2.20.4 |
Pmu resume from failure. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPmuInvalid |
1.3.6.1.4.1.2011.5.25.219.2.20.5 |
Pmu is invalid for some reason. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwPmuInvalidResume |
1.3.6.1.4.1.2011.5.25.219.2.20.6 |
Pmu resume from invalid situation. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwRATEOFTRAFFICRising |
1.3.6.1.4.1.2011.5.25.219.2.21.1 |
Rate of traffic overrun. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwRATEOFTRAFFICResume |
1.3.6.1.4.1.2011.5.25.219.2.21.2 |
Rate of traffic back to normal level. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwBatteryFull |
1.3.6.1.4.1.2011.5.25.219.2.22.1 |
battery percent is full . |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwEntityTrapCompliance |
1.3.6.1.4.1.2011.5.25.219.3.1.1 |
Compliance statement for agents that provide full support for
hwBaseTrapMIB. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
hwEntityObjectGroup |
1.3.6.1.4.1.2011.5.25.219.3.2.1 |
Group for base trap objects. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
hwEntityTrapGroup |
1.3.6.1.4.1.2011.5.25.219.3.2.2 |
Group for all base traps. |
Status: current |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|