HPN-ICF-TRANSCEIVER-INFO-MIB

File: HPN-ICF-TRANSCEIVER-INFO-MIB.mib (22504 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IF-MIB
HPN-ICF-OID-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
TruthValue ifIndex hpnicfCommon

Defined Types

HpnicfTransceiverInfoEntry  
SEQUENCE    
  hpnicfTransceiverHardwareType OCTET STRING
  hpnicfTransceiverType OCTET STRING
  hpnicfTransceiverWaveLength Integer32
  hpnicfTransceiverVendorName OCTET STRING
  hpnicfTransceiverSerialNumber OCTET STRING
  hpnicfTransceiverFiberDiameterType INTEGER
  hpnicfTransceiverTransferDistance Integer32
  hpnicfTransceiverDiagnostic TruthValue
  hpnicfTransceiverCurTXPower Integer32
  hpnicfTransceiverMaxTXPower Integer32
  hpnicfTransceiverMinTXPower Integer32
  hpnicfTransceiverCurRXPower Integer32
  hpnicfTransceiverMaxRXPower Integer32
  hpnicfTransceiverMinRXPower Integer32
  hpnicfTransceiverTemperature Integer32
  hpnicfTransceiverVoltage Integer32
  hpnicfTransceiverBiasCurrent Integer32
  hpnicfTransceiverTempHiAlarm Integer32
  hpnicfTransceiverTempLoAlarm Integer32
  hpnicfTransceiverTempHiWarn Integer32
  hpnicfTransceiverTempLoWarn Integer32
  hpnicfTransceiverVccHiAlarm Integer32
  hpnicfTransceiverVccLoAlarm Integer32
  hpnicfTransceiverVccHiWarn Integer32
  hpnicfTransceiverVccLoWarn Integer32
  hpnicfTransceiverBiasHiAlarm Integer32
  hpnicfTransceiverBiasLoAlarm Integer32
  hpnicfTransceiverBiasHiWarn Integer32
  hpnicfTransceiverBiasLoWarn Integer32
  hpnicfTransceiverPwrOutHiAlarm Integer32
  hpnicfTransceiverPwrOutLoAlarm Integer32
  hpnicfTransceiverPwrOutHiWarn Integer32
  hpnicfTransceiverPwrOutLoWarn Integer32
  hpnicfTransceiverRcvPwrHiAlarm Integer32
  hpnicfTransceiverRcvPwrLoAlarm Integer32
  hpnicfTransceiverRcvPwrHiWarn Integer32
  hpnicfTransceiverRcvPwrLoWarn Integer32
  hpnicfTransceiverErrors BITS

HpnicfTransceiverChannelEntry  
SEQUENCE    
  hpnicfTransceiverChannelIndex Integer32
  hpnicfTransceiverChannelCurTXPower Integer32
  hpnicfTransceiverChannelCurRXPower Integer32
  hpnicfTransceiverChannelTemperature Integer32
  hpnicfTransceiverChannelBiasCurrent Integer32

Defined Values

hpnicfTransceiver 1.3.6.1.4.1.11.2.14.11.15.2.70
The objects in this MIB module are used to display the information of transceiver on interface.
MODULE-IDENTITY    

hpnicfTransceiverInfoAdm 1.3.6.1.4.1.11.2.14.11.15.2.70.1
OBJECT IDENTIFIER    

hpnicfTransceiverInfoTable 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1
This table show the information of transceiver on interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfTransceiverInfoEntry

hpnicfTransceiverInfoEntry 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1
The entry of the hpnicfTransceiverInfoTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfTransceiverInfoEntry  

hpnicfTransceiverHardwareType 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.1
Hardware type of the interface, such as SM(single mode).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpnicfTransceiverType 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.2
Type of the interface, such as SFP/XFP/GBIC.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpnicfTransceiverWaveLength 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.3
Wave length of the interface, measured in nanometer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverVendorName 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.4
Vendor name of the interface.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpnicfTransceiverSerialNumber 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.5
Serial number of the interface.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpnicfTransceiverFiberDiameterType 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.6
The diameter of the fiber, measured in micron. fiber9 - 9 micron multi-mode fiber fiber50 - 50 micron multi-mode fiber fiber625 - 62.5 micron multi-mode fiber copper - copper cable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fiber9(1), fiber50(2), fiber625(3), copper(4), unknown(65535)  

hpnicfTransceiverTransferDistance 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.7
The maximal distance which the interface could transmit, measured in meter.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverDiagnostic 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.8
Indicating the digital diagnostic monitoring function .
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hpnicfTransceiverCurTXPower 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.9
Indicating the current transmitted power . The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverMaxTXPower 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.10
Indicating the maximal transmitted power . The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverMinTXPower 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.11
Indicating the minimal transmitted power . The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverCurRXPower 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.12
Indicating the current received power . The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverMaxRXPower 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.13
Indicating the maximal received power . The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverMinRXPower 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.14
Indicating the minimal received power . The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverTemperature 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.15
Indicating the current temperature. The unit is Celsius centigrade.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverVoltage 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.16
Indicating the current voltage . The unit is in hundredths of V
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverBiasCurrent 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.17
Indicating the current bias electric current . The unit is in hundredths of mA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverTempHiAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.18
Transceiver temperature high alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverTempLoAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.19
Transceiver temperature low alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverTempHiWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.20
Transceiver temperature high warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverTempLoWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.21
Transceiver temperature low warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverVccHiAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.22
Transceiver VCC high alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverVccLoAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.23
Transceiver VCC low alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverVccHiWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.24
Transceiver VCC high warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverVccLoWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.25
Transceiver VCC low warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverBiasHiAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.26
Transceiver bias high alarm threshold limit in microamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverBiasLoAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.27
Transceiver bias low alarm threshold limit in microamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverBiasHiWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.28
Transceiver bias high warning threshold limit in microamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverBiasLoWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.29
Transceiver bias low warning threshold limit in microamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverPwrOutHiAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.30
Transceiver transmit power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverPwrOutLoAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.31
Transceiver transmit power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverPwrOutHiWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.32
Transceiver transmit power high warning threshold limit in tenths of microwatts As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverPwrOutLoWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.33
Transceiver transmit power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverRcvPwrHiAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.34
Transceiver receive power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverRcvPwrLoAlarm 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.35
Transceiver receive power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverRcvPwrHiWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.36
Transceiver receive power high warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverRcvPwrLoWarn 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.37
Transceiver receive power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverErrors 1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.38
Bitmask indicating transceiver errors. Transceiver information I/O error(0) Transceiver information checksum error(1) Transceiver type and port configuration mismatch(2) Transceiver type not supported by port hardware(3) WIS local fault(4) Receive optical power fault(5) PMA/PMD receiver local fault(6) PCS receive local fault(7) PHY XS receive local fault(8) Laser bias current fault(9) Laser temperature fault(10) Laser output power fault(11) TX fault(12) PMA/PMD transmitter local fault(13) PCS transmit local fault(14) PHY XS Transmit Local Fault(15) RX loss of signal(16) Unused(17-31)
Status: current Access: read-only
OBJECT-TYPE    
  BITS xcvrIOError(0), xcvrChecksum(1), xcvrTypeAndPortConfigMismatch(2), xcvrTypeNotSupported(3), wisLocalFault(4), rcvOpticalPowerFault(5), pmapmdReceiverLocalFault(6), pcsReceiveLocalFault(7), phyXSReceiveLocalFault(8), laserBiasCurrentFault(9), laserTemperatureFault(10), laserOutputPowerFault(11), txFault(12), pmapmdTransmitterLocalFault(13), pcsTransmitLocalFault(14), phyXSTransmitLocalFault(15), rxLossOfSignal(16)  

hpnicfTransceiverChannelTable 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2
This table provides statistics about transceiver with multi-channel.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfTransceiverChannelEntry

hpnicfTransceiverChannelEntry 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1
The entry of the hpnicfTransceiverChannelTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfTransceiverChannelEntry  

hpnicfTransceiverChannelIndex 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.1
The channel index of transceiver. Indicating one channel of the interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

hpnicfTransceiverChannelCurTXPower 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.2
Indicating the current transmission power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverChannelCurRXPower 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.3
Indicating the current received power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverChannelTemperature 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.4
Indicating the current temperature. The unit is Celsius centigrade.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfTransceiverChannelBiasCurrent 1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.5
Indicating the current bias electric current. The unit is in hundredths of mA.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32