HPN-ICF-HPEOC-MIB

File: HPN-ICF-HPEOC-MIB.mib (31529 bytes)

Imported modules

HPN-ICF-OID-MIB IF-MIB SNMPv2-SMI
SNMPv2-TC

Imported symbols

hpnicfCommon ifIndex Integer32
Unsigned32 Counter64 OBJECT-TYPE
MODULE-IDENTITY IpAddress DisplayString
TruthValue MacAddress RowStatus

Defined Types

HpnicfHPEOCCltVlanManEntry  
SEQUENCE    
  hpnicfHPEOCCltEthPortType INTEGER

HpnicfHPEOCCltSysManEntry  
SEQUENCE    
  hpnicfHPEOCCltDescr DisplayString
  hpnicfHPEOCCltFwVersion DisplayString
  hpnicfHPEOCCltLinkState INTEGER

HpnicfHPEOCCnuSysManEntry  
SEQUENCE    
  hpnicfHPEOCCnuBcastControl TruthValue
  hpnicfHPEOCCnuAnonymStatus TruthValue
  hpnicfHPEOCCnuMacLimit Unsigned32

HpnicfHPEOCCableInfoEntry  
SEQUENCE    
  hpnicfHPEOCFECErrors Counter64
  hpnicfHPEOCAvgBitsPerCarrier Unsigned32
  hpnicfHPEOCAvgSNRPerCarrier Integer32
  hpnicfHPEOCAvgInPBCRCErrors Unsigned32
  hpnicfHPEOCInTotalPkts Counter64
  hpnicfHPEOCAvgOutPower Integer32
  hpnicfHPEOCAvgOutPBCRCErrors Unsigned32
  hpnicfHPEOCOutTotalPkts Counter64

HpnicfHPEOCBitPerSymbolEntry  
SEQUENCE    
  hpnicfHPEOCBitPerSymbolIndex Unsigned32
  hpnicfHPEOCBitPerSymbol OCTET STRING

HpnicfHPEOCTemplateGlobalEntry  
SEQUENCE    
  hpnicfHPEOCTemplateIndex Integer32
  hpnicfHPEOCTemplateType Integer32
  hpnicfHPEOCTemplateName DisplayString
  hpnicfHPEOCTemplateDescr DisplayString
  hpnicfHPEOCTemplateCnuMaxDownBW Integer32
  hpnicfHPEOCTemplateCnuMaxUpBW Integer32
  hpnicfHPEOCTemplateCnuBcastControl TruthValue
  hpnicfHPEOCTemplateCnuMacLimit Unsigned32
  hpnicfHPEOCTemplateCb201VlanEn TruthValue
  hpnicfHPEOCTemplateRowStatus RowStatus

HpnicfHPEOCTemplateSwitchEntry  
SEQUENCE    
  hpnicfHPEOCTemplateUniIndex Integer32
  hpnicfHPEOCTemplateUniSpeed INTEGER
  hpnicfHPEOCTemplateUniDuplex INTEGER
  hpnicfHPEOCTemplateUniPriority Integer32
  hpnicfHPEOCTemplateUniFlowControl TruthValue
  hpnicfHPEOCTemplateUniUpLineRate Unsigned32
  hpnicfHPEOCTemplateUniDownLineRate Unsigned32
  hpnicfHPEOCTemplateUniAdminStatus INTEGER
  hpnicfHPEOCTemplateUniVLANType INTEGER
  hpnicfHPEOCTemplateUniPvid Integer32
  hpnicfHPEOCTemplateUniVlanTag INTEGER

HpnicfHPEOCCnuAccessEntry  
SEQUENCE    
  hpnicfHPEOCCnuAccessIndex Integer32
  hpnicfHPEOCCnuHFID DisplayString
  hpnicfHPEOCManuInfo DisplayString
  hpnicfHPEOCCnuType Integer32
  hpnicfHPEOCCnuSwitchType Integer32
  hpnicfHPEOCCnuUniNum Integer32
  hpnicfHPEOCCnuPhy2Uni OCTET STRING
  hpnicfHPEOCCnuAccessRowStatus RowStatus

Defined Values

hpnicfHPEOC 1.3.6.1.4.1.11.2.14.11.15.2.84
The objects in this MIB module are used to manage and display current configuration of Ethernet Over Cable Network (EOC) which based on HomePlug(HP) AV Specification.
MODULE-IDENTITY    

hpnicfHPEOCSystem 1.3.6.1.4.1.11.2.14.11.15.2.84.1
OBJECT IDENTIFIER    

hpnicfHPEOCCltVlanType 1.3.6.1.4.1.11.2.14.11.15.2.84.1.1
Control EOC CLT's VLAN type, ieee8021q : 802.1q VLAN mode, portbased : portbased VLAN mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ieee8021q(1), portbased(2)  

hpnicfHPEOCCltVlanManTable 1.3.6.1.4.1.11.2.14.11.15.2.84.1.2
This table implements the management of CLT(Coax Line Terminal) VLAN.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfHPEOCCltVlanManEntry

hpnicfHPEOCCltVlanManEntry 1.3.6.1.4.1.11.2.14.11.15.2.84.1.2.1
The entry of the table hpnicfHPEOCCltVlanManTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfHPEOCCltVlanManEntry  

hpnicfHPEOCCltEthPortType 1.3.6.1.4.1.11.2.14.11.15.2.84.1.2.1.1
Control CLT ethernet ports' type, normal : port which used for normal translation, debug : port which used for debug.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), debug(2)  

hpnicfHPEOCCltSysManTable 1.3.6.1.4.1.11.2.14.11.15.2.84.1.3
This table implements the management of CLT(Coax Line Terminal).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfHPEOCCltSysManEntry

hpnicfHPEOCCltSysManEntry 1.3.6.1.4.1.11.2.14.11.15.2.84.1.3.1
The entry of the table hpnicfHPEOCCltSysManTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfHPEOCCltSysManEntry  

hpnicfHPEOCCltDescr 1.3.6.1.4.1.11.2.14.11.15.2.84.1.3.1.1
Set the description of CLT.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..126)  

hpnicfHPEOCCltFwVersion 1.3.6.1.4.1.11.2.14.11.15.2.84.1.3.1.2
EOC firmware version. If the object length is zero, it means the version is unknown.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

hpnicfHPEOCCltLinkState 1.3.6.1.4.1.11.2.14.11.15.2.84.1.3.1.3
The cable port's link state. The physicaldown(1) state indicates that the CLT is not powered on. The linkdown(2) state indicates that the CLT is powered on, but registers fail. The linkup(3) state indicates that the CLT is powered on, and registers successful. The loopback(4) state indecates that the CLT is powered on and registers successful, but loopback has detected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER physicaldown(1), linkdown(2), linkup(3), loopback(4)  

hpnicfHPEOCCnuSysManTable 1.3.6.1.4.1.11.2.14.11.15.2.84.1.4
This table implements the management of CNUs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfHPEOCCnuSysManEntry

hpnicfHPEOCCnuSysManEntry 1.3.6.1.4.1.11.2.14.11.15.2.84.1.4.1
The entry of the table hpnicfHPEOCCnuSysManTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfHPEOCCnuSysManEntry  

hpnicfHPEOCCnuBcastControl 1.3.6.1.4.1.11.2.14.11.15.2.84.1.4.1.1
Broadcast storm suppression status. true(1) - Broadcast storm suppression enable. false(2) - Broadcast storm suppression disable.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpnicfHPEOCCnuAnonymStatus 1.3.6.1.4.1.11.2.14.11.15.2.84.1.4.1.2
Anonymity status. true(1) - the user which uses the CNU is anonymous. false(2) - the user which uses the CNU has an account.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hpnicfHPEOCCnuMacLimit 1.3.6.1.4.1.11.2.14.11.15.2.84.1.4.1.3
Configure the max number of MAC address entries which can access through the CNU, it ranges from 1 to 8. Otherwise, If configure 0, the CNU won't limit the MAC address entry. If configure 0xFF, it means no MAC address entry can access the CNU.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

hpnicfHPEOCCltAutoUpgrade 1.3.6.1.4.1.11.2.14.11.15.2.84.1.5
Auto upgrade Status. true(1) - The firmware of the CNU will be auto changed by CLT. false(2)- The firmware of the CNU will not be auto changed.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpnicfHPEOCOnLineCnuNumber 1.3.6.1.4.1.11.2.14.11.15.2.84.1.6
The total number of the online CNU(s).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCCpuMacAddress 1.3.6.1.4.1.11.2.14.11.15.2.84.1.7
EOC CPU's MAC address.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

hpnicfHPEOCOffLineCnuNumber 1.3.6.1.4.1.11.2.14.11.15.2.84.1.8
The total number of the offline CNU(s).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCDownLoadCNUFWResult 1.3.6.1.4.1.11.2.14.11.15.2.84.1.9
Download CNU firmware result.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

hpnicfHPEOCCltAutoUpgradeType 1.3.6.1.4.1.11.2.14.11.15.2.84.1.10
Type of auto upgrade status. It depends on hpnicfHPEOCCltAutoUpgrade status. flash - The CLT auto upgrade the firmware inside its flash to the CNUs. ftp - First download the firmware from FTP server to the CLT, then the CLT auto upgrade the firmware to the CNUs. tftp - First download the firmware from TFTP server to the CLT, then the CLT auto upgrade the firmware to the CNUs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER flash(1), ftp(2), tftp(3)  

hpnicfHPEOCAutoUpObjects 1.3.6.1.4.1.11.2.14.11.15.2.84.1.11
OBJECT IDENTIFIER    

hpnicfHPEOCServerAddress 1.3.6.1.4.1.11.2.14.11.15.2.84.1.11.1
The address of remote host acting as server for operation. The default value is 0.0.0.0
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

hpnicfHPEOCServerUser 1.3.6.1.4.1.11.2.14.11.15.2.84.1.11.2
When using ftp to transfer files, the user name must be specified through this node. It contains 1 to 30 characters.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

hpnicfHPEOCServerPassword 1.3.6.1.4.1.11.2.14.11.15.2.84.1.11.3
Remote user password for copying via ftp protocol. Optionally, this object may be ignored for protocols other than ftp. It contains 1 to 31 characters.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

hpnicfHPEOCCltLoopbackDetect 1.3.6.1.4.1.11.2.14.11.15.2.84.1.12
Loopback detect Status. true(1) - The loopback detect is enabled. false(0)- The loopback detect is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

hpnicfHPEOCTemplateEnable 1.3.6.1.4.1.11.2.14.11.15.2.84.1.13
Use template for white-list cnu. true(1) - Use template is enabled. false(0)- Use template detect is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

hpnicfHPEOCCableInfo 1.3.6.1.4.1.11.2.14.11.15.2.84.2
OBJECT IDENTIFIER    

hpnicfHPEOCCableInfoTable 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1
This table defines the primary parameters of the cable information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfHPEOCCableInfoEntry

hpnicfHPEOCCableInfoEntry 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1.1
The entry of the table hpnicfHPEOCCableInfoTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfHPEOCCableInfoEntry  

hpnicfHPEOCFECErrors 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1.1.1
The cable port's FEC bits errors ratio. FEC means the payload Forward Error Correction. It's a technology of controlling errors. Packets in transmission is checked by the receiver, if error occurs, the receiver will announce the sender to resend.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

hpnicfHPEOCAvgBitsPerCarrier 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1.1.2
The cable port's average bits per carrier.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hpnicfHPEOCAvgSNRPerCarrier 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1.1.3
The cable port's signal noise ratio(SNR) bits per carrier.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCAvgInPBCRCErrors 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1.1.4
The input PB CRC errors on average.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hpnicfHPEOCInTotalPkts 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1.1.5
The total number of packets(including bad packets) received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

hpnicfHPEOCAvgOutPower 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1.1.6
The cable port's power sent on average, the unit is db.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCAvgOutPBCRCErrors 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1.1.7
The cable port's physical block(PB) cyclic redundancy check(CRC) errors sent on average.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hpnicfHPEOCOutTotalPkts 1.3.6.1.4.1.11.2.14.11.15.2.84.2.1.1.8
The total count of the packets(including bad packets) sent on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

hpnicfHPEOCBitPerSymbolTable 1.3.6.1.4.1.11.2.14.11.15.2.84.2.2
This table defines the bits per symbol parameters of the cable line.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfHPEOCBitPerSymbolEntry

hpnicfHPEOCBitPerSymbolEntry 1.3.6.1.4.1.11.2.14.11.15.2.84.2.2.1
The entry of the table hpnicfHPEOCBitPerSymbolTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfHPEOCBitPerSymbolEntry  

hpnicfHPEOCBitPerSymbolIndex 1.3.6.1.4.1.11.2.14.11.15.2.84.2.2.1.1
The index of the hpnicfHPEOCBitPerSymbolTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

hpnicfHPEOCBitPerSymbol 1.3.6.1.4.1.11.2.14.11.15.2.84.2.2.1.2
hpnicfHPEOCBitPerSymbol returns all the bits per symbol on the fixed frequency. Each 4 bits stand for one value, all the values picking-up will make up a cable bit map.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpnicfHPEOCTemplate 1.3.6.1.4.1.11.2.14.11.15.2.84.3
OBJECT IDENTIFIER    

hpnicfHPEOCTemplateGlobalTable 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1
This table defines the global parameters of the Template information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfHPEOCTemplateGlobalEntry

hpnicfHPEOCTemplateGlobalEntry 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1
The entry of the table hpnicfHPEOCTemplateGlobalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfHPEOCTemplateGlobalEntry  

hpnicfHPEOCTemplateIndex 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.1
The index of cable Template.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCTemplateType 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.2
The cable Template's type, can not change after create it.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 switch(1), gateway(2)  

hpnicfHPEOCTemplateName 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.3
The cable Template's name, it's recommended to set it uniquely and understandably. Length: 1 to 15 characters.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

hpnicfHPEOCTemplateDescr 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.4
The cable Template's description. Length: 0 to 63 characters.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

hpnicfHPEOCTemplateCnuMaxDownBW 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.5
Maximum downstream bandwidth allowed for the CNU, measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCTemplateCnuMaxUpBW 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.6
Maximum upstream bandwidth allowed for the CNU, measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCTemplateCnuBcastControl 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.7
Broadcast storm suppression status. true(1) - Broadcast storm suppression enable. false(2) - Broadcast storm suppression disable.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpnicfHPEOCTemplateCnuMacLimit 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.8
Configure the max number of MAC address entries which can access through the CNU, it ranges from 1 to 8. Otherwise, If configure 0, the CNU won't limit the MAC address entry. If configure 0xFF, it means no MAC address entry can access the CNU.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

hpnicfHPEOCTemplateCb201VlanEn 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.9
Use for Cb201 cnu only. true(1) - Enable vlan insert function. false(2) - Disable vlan insert function.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpnicfHPEOCTemplateRowStatus 1.3.6.1.4.1.11.2.14.11.15.2.84.3.1.1.10
Operation status.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hpnicfHPEOCTemplateSwitchTable 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2
This table defines the port parameters of the switch type cnu. it's not affect on the type of gateway Template.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfHPEOCTemplateSwitchEntry

hpnicfHPEOCTemplateSwitchEntry 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1
The entry of the table hpnicfHPEOCTemplateSwitchTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfHPEOCTemplateSwitchEntry  

hpnicfHPEOCTemplateUniIndex 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.1
The index value which uniquely identifies the FE interface of the CNU.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCTemplateUniSpeed 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.2
User network interface speed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), s10M(10), s100M(100)  

hpnicfHPEOCTemplateUniDuplex 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.3
User network interface mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), half(2), auto(3)  

hpnicfHPEOCTemplateUniPriority 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.4
The default ingress User Priority for this port. This only has effect on media, such as Ethernet, that do not support native User Priority.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..7  

hpnicfHPEOCTemplateUniFlowControl 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.5
Flow control status. true(1) - Flow control status enable. false(2) - Flow control status disable.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpnicfHPEOCTemplateUniUpLineRate 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.6
The max speed upload in units of 1,024 bits per second on this interface. The value should between 0 and 8Mbps. If the value is 0, it means that the upload speed is only restricted by the physical line.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

hpnicfHPEOCTemplateUniDownLineRate 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.7
The max speed download in units of 1,024 bits per second on this interface. The value should between 0 and 8Mbps. If the value is 0, it means that the download speed is only restricted by the physical line.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

hpnicfHPEOCTemplateUniAdminStatus 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.8
Control if open or close the UNI. If choose up(1), means the UNI is opened and packets can pass it. If choose down(2), means the UNI is closed and all packets will be discard.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2)  

hpnicfHPEOCTemplateUniVLANType 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.9
port vlan types. hybrid (3) port can carry multiple VLANs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER access(1), trunk(2), hybrid(3)  

hpnicfHPEOCTemplateUniPvid 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.10
The PVID, the VLAN ID assigned to untagged frames or Priority-Tagged frames received on this port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4094  

hpnicfHPEOCTemplateUniVlanTag 1.3.6.1.4.1.11.2.14.11.15.2.84.3.2.1.11
VLAN is set tagged or untagged.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tagged(1), untagged(2)  

hpnicfHPEOCCnuAccess 1.3.6.1.4.1.11.2.14.11.15.2.84.4
OBJECT IDENTIFIER    

hpnicfHPEOCCnuAccessTable 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1
This table defines the global parameters of the cnu type permitting to access.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfHPEOCCnuAccessEntry

hpnicfHPEOCCnuAccessEntry 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1.1
The entry of the table hpnicfHPEOCCnuAccessTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfHPEOCCnuAccessEntry  

hpnicfHPEOCCnuAccessIndex 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1.1.1
The index value which uniquely identifies the manuinfo of the CNU.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCCnuHFID 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1.1.2
The Cnu's HFID. Every type Cnu has it's unique HFID. Length: 1 to 64 characters.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

hpnicfHPEOCManuInfo 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1.1.3
The Cnu's manufactory infofamiont. Length: 0 to 63 characters.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

hpnicfHPEOCCnuType 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1.1.4
The Cnu's function type.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 switch(1), gateway(2)  

hpnicfHPEOCCnuSwitchType 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1.1.5
The Cnu's switch chip type. It's useless for gataway type cnu.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 rtl8306e(1), ar8236(2), mv6061(3), mv6031(4)  

hpnicfHPEOCCnuUniNum 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1.1.6
Uni number of the Cnu. It's useless for gataway type cnu.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hpnicfHPEOCCnuPhy2Uni 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1.1.7
Reflection from phy port to uni port of the cnu. It's useless for gataway type cnu. For example, phy port 0,1,2,3 is reflect to uni port 1,2,3,4, then the value of this mib is {0,1,2,3}
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

hpnicfHPEOCCnuAccessRowStatus 1.3.6.1.4.1.11.2.14.11.15.2.84.4.1.1.8
Operation status.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus