HP-SYSTEM-MIB

File: HP-SYSTEM-MIB.mib (19193 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
HP-BASE-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Gauge32
IpAddress NOTIFICATION-TYPE Unsigned32
Integer32 TEXTUAL-CONVENTION TruthValue
DisplayString MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP hpProcurveCommon

Defined Types

HpFanStatusEntry  
SEQUENCE    
  hpFanNumber INTEGER
  hpFanOperational INTEGER
  hpFanSpeed Integer32

Defined Values

hpProcurveSystem 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1
This MIB module describes objects for basic management of devices in the HP Procurve product line.
MODULE-IDENTITY    

hpProcurveSysMib 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1
OBJECT IDENTIFIER    

hpSystemMIBObjects 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2
OBJECT IDENTIFIER    

hpConfig 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1
OBJECT IDENTIFIER    

hpStatus 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.2
OBJECT IDENTIFIER    

hpNotificationsConfig 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.3
OBJECT IDENTIFIER    

hpProductDescription 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.1
Textual Description of the HW product
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpProductHWVersion 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.2
HW version of the product
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpProductSWVersion 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.3
SW version of the product
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpProductSerialNumber 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.4
Serial Number of the product
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpProductLastChange 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.5
Date and time of last configuration change
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpCpuTemperature 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.6
Current temperature in degrees centigrade of the CPU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpPowerSupplyTemperature 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.7
Current temperature in degrees centigrade of the power supply.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpChassisTemperature 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.8
Current temperature in degrees centigrade of the mother board. Note: this is not the ambient temperature of the box.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hpFanStatusTable 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.9
Table of operational status of all internal cooling fans.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpFanStatusEntry

hpFanStatusEntry 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.9.1
Entry in table of all internal cooling fans.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpFanStatusEntry  

hpFanNumber 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.9.1.1
Identifier of cooling fan, numbered to represent what hardware the fan is supposed to be cooling.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cpu(1), power(2)  

hpFanOperational 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.9.1.2
Operational status of a cooling fan.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

hpFanSpeed 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.1.9.1.3
Speed of the fan in RPM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpName 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1.2
A textual string containing information about the device. For instance, this string reflects the setting of the HP J8162A XL Access Controller Module Name available on the Administrative Web based User Interface. If no HP J8162A XL Access Controller Module name is entered, this object contains a zero-length string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

hpSystemID 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1.3
The unique identifier for this device, as used by this system, or a master controlling system. For instance, an HP J8162A XL Access Controller Module would report the systemID used by the Access Control Server 740wl to uniquely identify this device.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hpState 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1.4
The current state of the device. A HP ProCurve Networking Business device can be configured for standalone operation, Failover (ie with a redundant peer), or for Distribution of configuration from a controlling central system to remote entities. unknown(1) - system Configuration status unknown up(2) - a standalone system is operational. down(3) - a system is not operational. primary(4) - system is running as the primary in a Failover peer configuration. secondary(5) - system is running as the backup in a Failover peer configuration.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), up(2), down(3), primary(4), secondary(5)  

hpDistributionType 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1.5
The most recent distribution event type on a device. This object will change dynamically based on the most recently triggered distribution event. unknown(1) - the distribution event type none(2) - no distribution event has occurred rightsPush(3) - the central Access Control Server 740wl has triggered a rights push event to remote Access Control Server 740wls.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), rightsPush(2)  

hpDistributionStatus 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1.6
The most recent distribution event on a device. This object will change dynamically based on the most recently triggered distribution event. unknown(1) - the distribution event status unknown succeeded(2) - no distribution event has succeeded failed(3) - the distribution event failed for some reason.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), succeeded(2), failed(3)  

hpIpAddress 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1.7
The administratively assigned IP address associated with the device. This can be assigned statically on the device Console port, or configured via DHCP.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

hpPeerIpAddress 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1.8
The administratively assigned IP address associated with a redundant peer device, configured to work with this device for failover purposes. This can be assigned statically on the device Console port, or configured via DHCP. If the device does not support Failover configuration, or none has been configured, this object will report 0.0.0.0
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

hpTechSupportEnabled 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1.9
This object contains the current setting for the technical support access to the device. A value of true(1) indicates the Technical Support Access has been enabled. A value of false(2) indicates this access has been disabled. Note this object should only report true(2) if HP ProCurve Networking Business Technical Support staff have requested this access to the HP J8162A XL Access Controller Module for troubleshooting purposes.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpFailedAdminIpAddress 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.1.10
The IP address associated with the last failed authentication to the Administrative UI. If no Administrator had failed authentication, this object will report 0.0.0.0
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

hpNumAccessControllers 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.2.1
The number of HP J8162A XL Access Controller Modules known to this system. If this system is an HP J8162A XL Access Controller Module, this value will be 1. Otherwise, this value will be the number of HP J8162A XL Access Controller Modules this system is connected to (i.e. An Access Control Server 740wl connects to multiple HP J8162A XL Access Controller Module's).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hpNumClients 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.2.2
The total number of active authenticated or unauthenticated clients known to this system. If this device is an HP J8162A XL Access Controller Module, then this object reports the aggregated number of clients across all ports. If this device is a Access Control Server 740wl, it reports all Clients aggregated across all HP J8162A XL Access Controller Modules known to this system.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

hpFailoverNotificationEnabled 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.3.1
This object controls whether a hpFailover notification will be sent in the event of a failover occurrence between a primary and standby system. By default this object is set to false(2) for all systems.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpDistributionNotificationEnabled 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.3.2
This object controls whether a hpDistribution notification will be sent in the event of a distribution event between a central and remote systems. By default this object is set to false(2) for all systems.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpAdminAuthFailureNotificationEnabled 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.2.3.3
This object controls whether a hpAdminAuthFailure notification will be sent in the event of a failed authentication attempt at the administrator login.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpSystemTraps 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.0
OBJECT IDENTIFIER    

fanDown 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.0.1
A fanDown trap signifies that hpFanOperational has detected an event where the fan is not operating.
Status: current Access: read-write
NOTIFICATION-TYPE    

fanUp 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.0.2
A fanUp trap signifies that hpFanOperational has detected an event where the fan is now operating.
Status: current Access: read-write
NOTIFICATION-TYPE    

temperatureAlarm 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.0.3
A temperatureAlarm signifies that the SNMP entity, acting in an agent role, has detected that the hpCpuTemperature has a value that exceeds acceptable tolerances (i.e. it is too hot or too cold).
Status: current Access: read-write
NOTIFICATION-TYPE    

hpFailover 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.0.4
A hpFailover signifies that the SNMP entity, acting in an agent role, has detected that the standby system in a primary, redundant operation has become the primary system. This notification will only be sent by what was formerly the standby system.
Status: current Access: read-write
NOTIFICATION-TYPE    

hpDistributionEvent 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.0.5
A hpDistributionEvent signifies that the SNMP entity, acting in an agent role, has detected that the central entity in a distributed system has triggered a distribution event of hpDistributionType.
Status: current Access: read-write
NOTIFICATION-TYPE    

hpAdminAuthFailure 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.0.6
A hpAdminAuthFailure signifies that the SNMP entity, acting in an agent role, has detected that someone at the address reported by hpAdminIpAddress has failed to authenticate to the device via the administrative interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

hpSystemMIBConformance 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3
OBJECT IDENTIFIER    

hpCompliances 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3.1
OBJECT IDENTIFIER    

hpGroups 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3.2
OBJECT IDENTIFIER    

hpSystemMIBCompliance1 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3.1.1
The compliance statement for entities which implement the HP-SYSTEM-MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

hpSystemGroup 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3.2.1
A collection of objects providing system information applicable to all devices.
Status: current Access: read-only
OBJECT-GROUP    

hpEnvGroup 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3.2.2
A collection of objects providing environmental information applicable to all devices.
Status: current Access: read-only
OBJECT-GROUP    

hpConfigGroup 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3.2.3
A collection of objects providing configuration information applicable to all devices.
Status: current Access: read-only
OBJECT-GROUP    

hpStatusGroup 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3.2.4
A collection of objects providing statistics applicable to all HP J8162A XL Access Controller Module like devices.
Status: current Access: read-only
OBJECT-GROUP    

hpNotificationsConfigGroup 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3.2.5
A collection of objects providing notification configuration information applicable to all devices.
Status: current Access: read-only
OBJECT-GROUP    

hpNotificationsGroup 1.3.6.1.4.1.11.2.3.7.11.17.7.1.1.3.2.6
notifications for primary failover, and authorization failures, applicable to all devices.
Status: current Access: read-only
NOTIFICATION-GROUP