HP-SWITCH-BASIC-CONFIG-MIB

File: HP-SWITCH-BASIC-CONFIG-MIB.mib (42053 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
CONFIG-MIB Q-BRIDGE-MIB SMON-MIB
ENTITY-MIB INET-ADDRESS-MIB

Imported symbols

OBJECT-TYPE MODULE-IDENTITY Integer32
IpAddress Unsigned32 NOTIFICATION-TYPE
Counter32 RowStatus DisplayString
DateAndTime TruthValue MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP hpSwitchConfig
hpSwitchFilterConfig hpSwitchIgmpConfig PortList
portCopyEntry entPhysicalIndex InetAddressType
InetAddress

Defined Types

HpSwitchAliasEntry  
SEQUENCE    
  hpSwitchAliasName DisplayString
  hpSwitchAliasCommand OCTET STRING
  hpSwitchAliasConfigRowStatus RowStatus

HpicfBridgeFilterConfigEntry  
SEQUENCE    
  hpicfBridgeFilterName DisplayString
  hpicfBridgeFilterDropPortMask PortList
  hpicfBridgeFilterEntryStatus RowStatus

HpSwitchIgmpProxyDomainConfigEntry  
SEQUENCE    
  hpSwitchIgmpProxyDomainId Integer32
  hpSwitchIgmpProxyDomainStatus RowStatus
  hpSwitchIgmpProxyDomainName DisplayString
  hpSwitchIgmpProxyDomainIp IpAddress
  hpSwitchIgmpProxyMcastLowerIp IpAddress
  hpSwitchIgmpProxyMcastUpperIp IpAddress

HpicfPortCopyNameEntry  
SEQUENCE    
  hpicfPortCopyName DisplayString

HpSwitchChassisLocateEntry  
SEQUENCE    
  hpSwitchChassisLocateState INTEGER
  hpSwitchChassisLocateDuration Integer32

HpSwitchModuleInfoEntry  
SEQUENCE    
  hpSwitchModuleInfoModId Integer32
  hpSwitchModuleInfoModType DisplayString

HpSwitchModuleConfigEntry  
SEQUENCE    
  hpSwitchModuleConfigModType DisplayString
  hpSwitchModuleConfigModName DisplayString

HpSwitchRunningCfgChgEventEntry  
SEQUENCE    
  hpSwitchRunningCfgChgEventTableIndex Integer32
  hpSwitchRunningCfgChgEventId Unsigned32
  hpSwitchRunningCfgChgEventMethod INTEGER
  hpSwitchRunningCfgChgEventSourceIPAddrType InetAddressType
  hpSwitchRunningCfgChgEventSourceIPAddr InetAddress
  hpSwitchRunningCfgChgEventUsername DisplayString
  hpSwitchRunningCfgChgEventDateAndTime DateAndTime

Defined Values

hpSwitchBasicConfigMIB 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29
This MIB module describes objects for basic switch configuration.
MODULE-IDENTITY    

hpSwitchBasicConfigObjects 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1
OBJECT IDENTIFIER    

hpSwitchBasicConfigConformance 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2
OBJECT IDENTIFIER    

hpSwitchACLConfig 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.3
OBJECT IDENTIFIER    

hpSwitchModules 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7
OBJECT IDENTIFIER    

hpSwitchRunningCfgChgObjects 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12
OBJECT IDENTIFIER    

hpSwitchSaveConfig 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.1
When this object is set to to 'saveConfig' it results in saving the running configuration of the switch to flash. The saved configuration becomes the boot-up configuration of the switch when it boots next time. When read, this object always returns 'noConfigSave'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConfigSave(1), saveConfig(2)  

hpSwitchAliasTable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2
Table of alias configurations for CLI commands. This table contains information about name of the alias and the corresponding CLI command.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpSwitchAliasEntry

hpSwitchAliasEntry 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2.1
A row in the alias config table.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpSwitchAliasEntry  

hpSwitchAliasName 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2.1.1
Name of the alias which uniquely identifies alias configuration table. 'hpSwitchAliasName' can be used in place of 'hpSwitchAliasCommand` on the CLI. Maximum allowed length for alias name is 32 characters.
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(0..100)  

hpSwitchAliasCommand 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2.1.2
CLI command for which 'hpSwitchAliasName' can be used in CLI. Maximum allowed length for alias command is 255 characters. This object is required to create an entry in the table.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

hpSwitchAliasConfigRowStatus 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2.1.3
Controls creation/deletion of entries in alias table. Row cant be created when 'hpSwitchAliasCommand' is of zero length. Row transition to 'notReady' or 'notInService' states are not allowed.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hpicfBridgeFilterConfigTable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.8.2
A table that contains information about the source port traffic filter configuration in this device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpicfBridgeFilterConfigEntry

hpicfBridgeFilterConfigEntry 1.3.6.1.4.1.11.2.14.11.5.1.7.1.8.2.1
Information about a source port traffic filter configuration in this device.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpicfBridgeFilterConfigEntry  

hpicfBridgeFilterName 1.3.6.1.4.1.11.2.14.11.5.1.7.1.8.2.1.1
This variable specifies the name of the filter. Filter name can be upto 20 characters. Filter name cannot contain tilde (~). A filter name can not be same as port-name.
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(0..100)  

hpicfBridgeFilterDropPortMask 1.3.6.1.4.1.11.2.14.11.5.1.7.1.8.2.1.2
This variable specifies a group of ports to which forwarding of filtered traffic is not permitted.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

hpicfBridgeFilterEntryStatus 1.3.6.1.4.1.11.2.14.11.5.1.7.1.8.2.1.3
Row can be deleted only when no port are mapped to this filter in 'hpSwitchFilterConfigEntry' table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hpSwitchAclLogtimeoutConfig 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.3.1
ACL deny entries can be logged to the syslog server. Log timeout is the period the switch waits before sending updates about any ACL deny matches to the syslog server. The same log timer will be used for ipv4 and ipv6 logging. The configurable value is from 30 to 300.Maximum limit is given as 65535 so that if the value is increased in the future, the mib need not be modified.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..65535  

hpSwitchIgmpProxyDomainConfigTable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5
A table that contains information about the IGMP proxy domain configurations on this switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpSwitchIgmpProxyDomainConfigEntry

hpSwitchIgmpProxyDomainConfigEntry 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1
The information associated with each IGMP proxy domain configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpSwitchIgmpProxyDomainConfigEntry  

hpSwitchIgmpProxyDomainId 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.1
The domain id that uniquely identifies a row in the IGMP proxy domain configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..65535  

hpSwitchIgmpProxyDomainStatus 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.2
The status of a IGMP proxy domain configuration entry. Allows creation/deletion of the IGMP proxy domain entry. Row cannot be deleted if the IGMP proxy domain is associated with a VLAN.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hpSwitchIgmpProxyDomainName 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.3
The IGMP proxy domain name.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

hpSwitchIgmpProxyDomainIp 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.4
The IGMP proxy domain IP.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hpSwitchIgmpProxyMcastLowerIp 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.5
The IGMP proxy domain's lower multicast IP.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hpSwitchIgmpProxyMcastUpperIp 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.6
The IGMP proxy domain's upper multicast IP.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hpicfPortCopyNameTable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.4
This table contains Mirroring Destination name String.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpicfPortCopyNameEntry

hpicfPortCopyNameEntry 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.4.1
An entry in the hpicfPortCopyNameEntry contains Mirroring Destination name string.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpicfPortCopyNameEntry  

hpicfPortCopyName 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.4.1.1
Mirroring Destination name string.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

hpSwitchDefaultLogon 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.5
This indicates whether switch should boot to CLI (default) or menu. The changes takes effect after rebooting the switch.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cli(0), menu(1)  

hpSwitchChassisLocateTable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.6
This table is contains information about the current state of all the chassis locate LEDs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpSwitchChassisLocateEntry

hpSwitchChassisLocateEntry 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.6.1
Contains information about the current state of a particular chassis LED.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpSwitchChassisLocateEntry  

hpSwitchChassisLocateState 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.6.1.1
The current state of the chassis LED. The state is set to 'off' by default.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), blink(3)  

hpSwitchChassisLocateDuration 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.6.1.2
The duration for which the current LED state is to be maintained. The minimum value is 60 and the maximum value is 86400. The 'off' state does not require a duration. A get request for the duration when the state is 'off' will return the default duration value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hpSwitchModuleInfoTable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.1
A table describing all modules that can be supported by the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpSwitchModuleInfoEntry

hpSwitchModuleInfoEntry 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.1.1
The information regarding the module type in the switch. This table lists all the supported module types. The supported module type will have the equivalent module name.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpSwitchModuleInfoEntry  

hpSwitchModuleInfoModId 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.1.1.1
The module Id. This is a sequence number
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..65535  

hpSwitchModuleInfoModType 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.1.1.2
The module type in the switch. This is the Jnumber string that is supported on the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..255)  

hpSwitchModuleConfigTable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.2
A table to configure the module type for a specific module.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpSwitchModuleConfigEntry

hpSwitchModuleConfigEntry 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.2.1
Configuration of module type for a specific module. Configuration of module type on an already configured module is not allowed.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpSwitchModuleConfigEntry  

hpSwitchModuleConfigModType 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.2.1.1
The module type in the switch. This is the Jnumber supported on the device. The supported types are listed in hpSwitchModuleInfoTable.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

hpSwitchModuleConfigModName 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.2.1.2
The module name in the switch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

hpSwitchWebSupportUrl 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.8
URL for the web interface support page.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

hpSwitchImplicitConfigSave 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.11
This object is to enable/disable the implicit write-memory (saving the running-config to the flash) done after every successful SNMP set operation. When set to 'enable', config changes are written to the flash which results in slow performance for these set operations. To get faster processing while doing large number of continuous SNMP set operations, this object can be set to 'disable'; And,once the SNMP set operations are done, 'hpSwitchSaveConfig' MIB object can be used to save the running-config to the flash. This object will not be saved across a re-boot, and will always be set to 'enable' at boot. It is advisable to set this MIB object to 'disable' only when there are a lot of continuous SNMP set operations e.g. a script executing a large number of SNMP set operations.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hpSwitchStartupConfigSeqNum 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.9
This is the value of the global startup-config sequential number. Every change to startup-config increments the value by 1. Must be stored in non-volatile memory to be carried over the system boot.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2147483647  

hpSwitchStartupConfigNotifyEnable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.10
Indicates whether the SNMP entity is permitted to generate hpSwitchStartupConfigChange notifications. Default is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hpSwitchSecureModeLevel 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.13
Indicates current Secure-Mode Level of switch standard : switch operates with standard security capabilities. enhanced : switch operates with enhanced security capabilities for configurations to satisfy FIPS 140-2 requirements.The default level is standard.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER error(0), standard(1), enhanced(16)  

hpSwitchNotificationObjects 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0
OBJECT IDENTIFIER    

hpSwitchStartupConfigSource 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.1
Indicate the method of change to startup config was initiated.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER unknown(0), viaCli(1), viaSnmp(2), viaWebUI(3)  

hpSwitchStartupConfigSourceIPAddrType 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.2
Indicates the source address type of network agent which made a change. Not valid (set to zero) if change is made via CLI on system console.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  InetAddressType  

hpSwitchStartupConfigSourceIPAddr 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.3
Indicates the source address of network agent which made a change. Not valid (set to zero) if change is made via CLI on system console.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  InetAddress  

hpSwitchStartupConfigSourceUsername 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.4
Indicates the username of CLI user making the change to startup config. Zero-string if username is not set or change is made via SNMP
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..255)  

hpSwitchStartupConfigThrottled 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.5
Indicates if notification throttle was activated and one or more notifications were dropped.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  TruthValue  

hpSwitchStartupConfigChange 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.6
The hpSwitchStartupConfigChange notification signifies that switch's startup config was modified by user/manager. Notifications might be buffered on the system to be sent after throttle delay. In some cases, notifications will be dropped. At such event the next transmitted notification will set flag hpSwitchStartupConfigThrottled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hpSwitchRunningCfgChgNotifyEnable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.1
Indicates whether the SNMP entity is permitted to generate hpSwitchRunningConfigChange notifications. Default is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hpSwitchRunningCfgChgTransmitInterval 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.2
Specifies the transmission interval in seconds for sending running config change traps. Only one running config change trap is sent in this time interval. Default value is 0, indicating there is no limit on sending running config change traps.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

hpSwitchRunningCfgChgLatestDateAndTime 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.3
Indicates the date and time of the most recent running config change.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

hpSwitchRunningCfgChgCount 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.4
The total number of running config changes since last reboot.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hpSwitchRunningCfgChgEntriesBumped 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.5
The number of times the oldest entry in hpSwitchRunningCfgChgTable was discarded to make room for a new entry.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hpSwitchRunningCfgChgEventTable 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6
A table of latest 32 running configuration change events.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpSwitchRunningCfgChgEventEntry

hpSwitchRunningCfgChgEventEntry 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1
Information about running configuration change event on this switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpSwitchRunningCfgChgEventEntry  

hpSwitchRunningCfgChgEventTableIndex 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.1
The Index for hpSwitchRunningCfgChgTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..100  

hpSwitchRunningCfgChgEventId 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.2
Identifies a specific running config change. Monotonically increasing values will be assigned by the system to each event as it occurs. If the system is reset, these event ID values will be reset as well.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..4294967295  

hpSwitchRunningCfgChgEventMethod 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.3
Indicates the source through which change to running config was initiated.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), cli(1), menu(2), snmp(3), webUI(4), internalEvent(5)  

hpSwitchRunningCfgChgEventSourceIPAddrType 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.4
Indicates the source address type of network agent which made a change. This object value is set to an address type of unknown when not applicable.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddressType  

hpSwitchRunningCfgChgEventSourceIPAddr 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.5
Indicates the source address of network agent which made a running config change. The value is an address of length 0 (unknown(0)) if not available or not applicable.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddress  

hpSwitchRunningCfgChgEventUsername 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.6
Indicates the username of the user making the change the change to running config. Empty string (length 0) if username is not available or not applicable.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

hpSwitchRunningCfgChgEventDateAndTime 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.7
Indicates the date and time of the running config change.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

hpSwitchRunningConfigChange 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.7
Notification of a running configuration change event as recorded in hpSwitchRunningCfgChgTable.
Status: current Access: read-only
NOTIFICATION-TYPE    

hpSwitchCdpRunMode 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.14
Indicates the mode of CDP processing. This variable has no effect when CDP is disabled (cdpGlobalRun = FALSE).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER rxonly(1), passthru(2)  

hpSwitchBasicConfigCompliances 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.1
OBJECT IDENTIFIER    

hpSwitchBasicConfigGroups 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2
OBJECT IDENTIFIER    

hpSwitchBasicNotificationGroups 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.3
OBJECT IDENTIFIER    

hpSwitchBasicConfigCompliance 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.1.1
The compliance statement for config entities which implements basic configuration of the switch.
Status: current Access: read-write
MODULE-COMPLIANCE    

hpSwitchBasicConfigCompliance2 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.1.2
The compliance statement for config entities which implements basic configuration of the switch.
Status: current Access: read-write
MODULE-COMPLIANCE    

hpSwitchBasicConfigCompliance3 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.1.3
The compliance statement for config entities which implements basic configuration of the switch.
Status: current Access: read-only
MODULE-COMPLIANCE    

hpSwitchBasicConfigCompliance4 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.1.4
The compliance statement for config entities which implements basic configuration of the switch.
Status: current Access: read-only
MODULE-COMPLIANCE    

hpSwitchBasicConfigGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.1
A collection of objects for basic configuration of the switch.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchAliasGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.2
A collection of objects for alias configuration for CLI commands.
Status: current Access: read-only
OBJECT-GROUP    

hpicfBridgeFilterConfigGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.3
A collection of objects for source-port filter configuration.
Status: current Access: read-only
OBJECT-GROUP    

hpicfPortCopyNameGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.4
A collection of objects for mirror configuration for CLI commands.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchAclLogtimeoutGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.5
A collection of objects for ACL configuration of the switch.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchIgmpProxyDomainConfigGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.6
A collection of objects for IGMP proxy domain configuration.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchChassisLocateGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.7
A collection of objects for chassis locate configuration.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchModuleGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.8
A collection of objects for switch module configuration.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchStartupConfigChangeGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.9
A collection of objects for startup config change notifications.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchBasicConfigGroup2 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.10
A collection of objects for switch basic configurations.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchRunningCfgChgGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.11
A collection of objects for running config change details and its notification.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchBasicConfigGroup3 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.12
A collection of objects for switch Secure mode configurations.
Status: current Access: read-only
OBJECT-GROUP    

hpSwitchBasicNotificationGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.3.1
Switch Basic Config notifications
Status: current Access: read-only
NOTIFICATION-GROUP    

hpSwitchCdpConfigGroup 1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.13
A collection of objects for Cisco discovery protocol mode configurations.
Status: current Access: read-only
OBJECT-GROUP