HP-SWITCH-BASIC-CONFIG-MIB
File:
HP-SWITCH-BASIC-CONFIG-MIB.mib (42053 bytes)
Imported modules
Imported symbols
Defined Types
HpSwitchAliasEntry |
|
SEQUENCE |
|
|
|
|
hpSwitchAliasName |
DisplayString |
|
|
hpSwitchAliasCommand |
OCTET STRING |
|
|
hpSwitchAliasConfigRowStatus |
RowStatus |
|
HpicfBridgeFilterConfigEntry |
|
SEQUENCE |
|
|
|
|
hpicfBridgeFilterName |
DisplayString |
|
|
hpicfBridgeFilterDropPortMask |
PortList |
|
|
hpicfBridgeFilterEntryStatus |
RowStatus |
|
HpSwitchIgmpProxyDomainConfigEntry |
|
SEQUENCE |
|
|
|
|
hpSwitchIgmpProxyDomainId |
Integer32 |
|
|
hpSwitchIgmpProxyDomainStatus |
RowStatus |
|
|
hpSwitchIgmpProxyDomainName |
DisplayString |
|
|
hpSwitchIgmpProxyDomainIp |
IpAddress |
|
|
hpSwitchIgmpProxyMcastLowerIp |
IpAddress |
|
|
hpSwitchIgmpProxyMcastUpperIp |
IpAddress |
|
HpSwitchChassisLocateEntry |
|
SEQUENCE |
|
|
|
|
hpSwitchChassisLocateState |
INTEGER |
|
|
hpSwitchChassisLocateDuration |
Integer32 |
|
HpSwitchModuleInfoEntry |
|
SEQUENCE |
|
|
|
|
hpSwitchModuleInfoModId |
Integer32 |
|
|
hpSwitchModuleInfoModType |
DisplayString |
|
HpSwitchModuleConfigEntry |
|
SEQUENCE |
|
|
|
|
hpSwitchModuleConfigModType |
DisplayString |
|
|
hpSwitchModuleConfigModName |
DisplayString |
|
HpSwitchRunningCfgChgEventEntry |
|
SEQUENCE |
|
|
|
|
hpSwitchRunningCfgChgEventTableIndex |
Integer32 |
|
|
hpSwitchRunningCfgChgEventId |
Unsigned32 |
|
|
hpSwitchRunningCfgChgEventMethod |
INTEGER |
|
|
hpSwitchRunningCfgChgEventSourceIPAddrType |
InetAddressType |
|
|
hpSwitchRunningCfgChgEventSourceIPAddr |
InetAddress |
|
|
hpSwitchRunningCfgChgEventUsername |
DisplayString |
|
|
hpSwitchRunningCfgChgEventDateAndTime |
DateAndTime |
|
Defined Values
hpSwitchBasicConfigMIB |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29 |
This MIB module describes objects for basic
switch configuration. |
MODULE-IDENTITY |
|
|
|
hpSwitchSaveConfig |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.1 |
When this object is set to to 'saveConfig' it
results in saving the running configuration of the
switch to flash. The saved configuration becomes
the boot-up configuration of the switch when it boots
next time. When read, this object always returns
'noConfigSave'. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noConfigSave(1), saveConfig(2) |
|
hpSwitchAliasTable |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2 |
Table of alias configurations for CLI commands.
This table contains information about name of the
alias and the corresponding CLI command. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
HpSwitchAliasEntry |
|
hpSwitchAliasEntry |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2.1 |
A row in the alias config table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HpSwitchAliasEntry |
|
|
hpSwitchAliasName |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2.1.1 |
Name of the alias which uniquely identifies
alias configuration table. 'hpSwitchAliasName' can be
used in place of 'hpSwitchAliasCommand` on the CLI.
Maximum allowed length for alias name is 32 characters. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..100) |
|
hpSwitchAliasCommand |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2.1.2 |
CLI command for which 'hpSwitchAliasName' can be
used in CLI. Maximum allowed length for alias command
is 255 characters. This object is required to create
an entry in the table. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hpSwitchAliasConfigRowStatus |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.2.1.3 |
Controls creation/deletion of entries
in alias table. Row cant be created when
'hpSwitchAliasCommand' is of zero length.
Row transition to 'notReady' or
'notInService' states are not allowed. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
hpicfBridgeFilterConfigEntry |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.8.2.1 |
Information about a source port traffic filter
configuration in this device. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HpicfBridgeFilterConfigEntry |
|
|
hpicfBridgeFilterName |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.8.2.1.1 |
This variable specifies the name of the
filter. Filter name can be upto 20 characters.
Filter name cannot contain tilde (~).
A filter name can not be same as port-name. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..100) |
|
hpicfBridgeFilterDropPortMask |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.8.2.1.2 |
This variable specifies a group of ports to which
forwarding of filtered traffic is not permitted. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
PortList |
|
|
hpicfBridgeFilterEntryStatus |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.8.2.1.3 |
Row can be deleted only when no port are mapped to
this filter in 'hpSwitchFilterConfigEntry' table. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
hpSwitchAclLogtimeoutConfig |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.3.1 |
ACL deny entries can be logged to the syslog server.
Log timeout is the period the switch waits before sending
updates about any ACL deny matches to the syslog server.
The same log timer will be used for ipv4 and ipv6 logging.
The configurable value is from 30 to 300.Maximum limit is given
as 65535 so that if the value is increased in the future, the mib need
not be modified. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..65535 |
|
hpSwitchIgmpProxyDomainConfigTable |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5 |
A table that contains information about the IGMP
proxy domain configurations on this switch. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
HpSwitchIgmpProxyDomainConfigEntry |
|
hpSwitchIgmpProxyDomainConfigEntry |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1 |
The information associated with each IGMP
proxy domain configuration. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HpSwitchIgmpProxyDomainConfigEntry |
|
|
hpSwitchIgmpProxyDomainId |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.1 |
The domain id that uniquely identifies a row
in the IGMP proxy domain configuration table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..65535 |
|
hpSwitchIgmpProxyDomainStatus |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.2 |
The status of a IGMP proxy domain configuration
entry. Allows creation/deletion of the
IGMP proxy domain entry. Row cannot be deleted if
the IGMP proxy domain is associated with a VLAN. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
hpSwitchIgmpProxyDomainName |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.3 |
The IGMP proxy domain name. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
hpSwitchIgmpProxyDomainIp |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.5.1.4 |
The IGMP proxy domain IP. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
hpicfPortCopyNameEntry |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.4.1 |
An entry in the hpicfPortCopyNameEntry contains
Mirroring Destination name string. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HpicfPortCopyNameEntry |
|
|
hpicfPortCopyName |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.4.1.1 |
Mirroring Destination name string. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
hpSwitchDefaultLogon |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.5 |
This indicates whether switch should boot to CLI (default)
or menu. The changes takes effect after rebooting the
switch. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
cli(0), menu(1) |
|
hpSwitchChassisLocateEntry |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.6.1 |
Contains information about the current state of a
particular chassis LED. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HpSwitchChassisLocateEntry |
|
|
hpSwitchChassisLocateState |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.6.1.1 |
The current state of the chassis LED. The state is
set to 'off' by default. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2), blink(3) |
|
hpSwitchChassisLocateDuration |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.6.1.2 |
The duration for which the current LED state is
to be maintained. The minimum value is 60 and the
maximum value is 86400. The 'off' state does not
require a duration. A get request for the duration
when the state is 'off' will return the default
duration value. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hpSwitchModuleInfoEntry |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.1.1 |
The information regarding the module type
in the switch. This table lists all the
supported module types. The supported module type
will have the equivalent module name. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HpSwitchModuleInfoEntry |
|
|
hpSwitchModuleInfoModId |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.1.1.1 |
The module Id. This is a sequence number |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..65535 |
|
hpSwitchModuleInfoModType |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.1.1.2 |
The module type in the switch.
This is the Jnumber string that is
supported on the device. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..255) |
|
hpSwitchModuleConfigEntry |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.2.1 |
Configuration of module type for a
specific module. Configuration of
module type on an already configured
module is not allowed. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HpSwitchModuleConfigEntry |
|
|
hpSwitchModuleConfigModType |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.7.2.1.1 |
The module type in the switch.
This is the Jnumber supported
on the device. The supported
types are listed in hpSwitchModuleInfoTable. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
hpSwitchWebSupportUrl |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.8 |
URL for the web interface support page. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
hpSwitchImplicitConfigSave |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.11 |
This object is to enable/disable the implicit
write-memory (saving the running-config to the
flash) done after every successful SNMP
set operation.
When set to 'enable', config changes are written to
the flash which results in slow performance for
these set operations.
To get faster processing while doing large number
of continuous SNMP set operations, this object can be
set to 'disable'; And,once the SNMP set operations are
done, 'hpSwitchSaveConfig' MIB object can be used
to save the running-config to the flash.
This object will not be saved across a re-boot,
and will always be set to 'enable' at boot.
It is advisable to set this MIB object to
'disable' only when there are a lot of
continuous SNMP set operations e.g. a script
executing a large number of SNMP set operations. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2) |
|
hpSwitchStartupConfigSeqNum |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.9 |
This is the value of the global startup-config
sequential number. Every change to startup-config
increments the value by 1. Must be stored in
non-volatile memory to be carried over the system boot. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2147483647 |
|
hpSwitchStartupConfigNotifyEnable |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.10 |
Indicates whether the SNMP entity is permitted
to generate hpSwitchStartupConfigChange notifications.
Default is disabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2) |
|
hpSwitchSecureModeLevel |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.13 |
Indicates current Secure-Mode Level of switch
standard : switch operates with standard security
capabilities.
enhanced : switch operates with enhanced security
capabilities for configurations to satisfy FIPS
140-2 requirements.The default level is standard. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
error(0), standard(1), enhanced(16) |
|
hpSwitchStartupConfigSource |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.1 |
Indicate the method of change to startup config
was initiated. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), viaCli(1), viaSnmp(2), viaWebUI(3) |
|
hpSwitchStartupConfigSourceIPAddrType |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.2 |
Indicates the source address type of network agent
which made a change. Not valid (set to zero)
if change is made via CLI on system console. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
InetAddressType |
|
|
hpSwitchStartupConfigSourceIPAddr |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.3 |
Indicates the source address of network agent
which made a change. Not valid (set to zero)
if change is made via CLI on system console. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
InetAddress |
|
|
hpSwitchStartupConfigSourceUsername |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.4 |
Indicates the username of CLI user making the
change to startup config. Zero-string if username
is not set or change is made via SNMP |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
hpSwitchStartupConfigThrottled |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.5 |
Indicates if notification throttle was activated
and one or more notifications were dropped. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
hpSwitchStartupConfigChange |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.6 |
The hpSwitchStartupConfigChange
notification signifies that switch's startup
config was modified by user/manager.
Notifications might be buffered on the system to
be sent after throttle delay. In some cases,
notifications will be dropped. At such event
the next transmitted notification will set
flag hpSwitchStartupConfigThrottled |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
hpSwitchRunningCfgChgNotifyEnable |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.1 |
Indicates whether the SNMP entity is permitted
to generate hpSwitchRunningConfigChange notifications.
Default is disabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2) |
|
hpSwitchRunningCfgChgTransmitInterval |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.2 |
Specifies the transmission interval in seconds
for sending running config change traps. Only
one running config change trap is sent in this
time interval. Default value is 0, indicating
there is no limit on sending running config
change traps. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
hpSwitchRunningCfgChgCount |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.4 |
The total number of running config changes
since last reboot. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
hpSwitchRunningCfgChgEntriesBumped |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.5 |
The number of times the oldest entry in
hpSwitchRunningCfgChgTable was discarded
to make room for a new entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
hpSwitchRunningCfgChgEventEntry |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1 |
Information about running configuration
change event on this switch. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HpSwitchRunningCfgChgEventEntry |
|
|
hpSwitchRunningCfgChgEventId |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.2 |
Identifies a specific running config change.
Monotonically increasing values will be
assigned by the system to each event as it
occurs. If the system is reset, these event ID
values will be reset as well. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
hpSwitchRunningCfgChgEventMethod |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.3 |
Indicates the source through which change to
running config was initiated. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), cli(1), menu(2), snmp(3), webUI(4), internalEvent(5) |
|
hpSwitchRunningCfgChgEventSourceIPAddrType |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.4 |
Indicates the source address type of network agent
which made a change. This object value is set to an
address type of unknown when not applicable. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
InetAddressType |
|
|
hpSwitchRunningCfgChgEventSourceIPAddr |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.5 |
Indicates the source address of network agent
which made a running config change. The value
is an address of length 0 (unknown(0)) if not
available or not applicable. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
InetAddress |
|
|
hpSwitchRunningCfgChgEventUsername |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.6.1.6 |
Indicates the username of the user making the change
the change to running config. Empty string (length 0)
if username is not available or not applicable. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
hpSwitchRunningConfigChange |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.0.7 |
Notification of a running configuration change
event as recorded in hpSwitchRunningCfgChgTable. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hpSwitchCdpRunMode |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.14 |
Indicates the mode of CDP processing. This variable
has no effect when CDP is disabled (cdpGlobalRun = FALSE). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
rxonly(1), passthru(2) |
|
hpSwitchBasicConfigCompliance |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.1.1 |
The compliance statement for config entities
which implements basic configuration of the switch. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
hpSwitchBasicConfigCompliance2 |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.1.2 |
The compliance statement for config entities
which implements basic configuration of the switch. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
hpSwitchBasicConfigCompliance3 |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.1.3 |
The compliance statement for config entities
which implements basic configuration of the switch. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
hpSwitchBasicConfigCompliance4 |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.1.4 |
The compliance statement for config entities
which implements basic configuration of the switch. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
hpSwitchBasicConfigGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.1 |
A collection of objects for basic configuration
of the switch. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchAliasGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.2 |
A collection of objects for alias configuration
for CLI commands. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpicfBridgeFilterConfigGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.3 |
A collection of objects for source-port filter
configuration. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpicfPortCopyNameGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.4 |
A collection of objects for mirror configuration
for CLI commands. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchAclLogtimeoutGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.5 |
A collection of objects for ACL configuration
of the switch. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchIgmpProxyDomainConfigGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.6 |
A collection of objects for IGMP proxy domain
configuration. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchChassisLocateGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.7 |
A collection of objects for chassis locate
configuration. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchModuleGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.8 |
A collection of objects for switch module
configuration. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchStartupConfigChangeGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.9 |
A collection of objects for startup
config change notifications. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchBasicConfigGroup2 |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.10 |
A collection of objects for switch basic
configurations. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchRunningCfgChgGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.11 |
A collection of objects for running
config change details and its notification. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchBasicConfigGroup3 |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.12 |
A collection of objects for switch Secure mode
configurations. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hpSwitchBasicNotificationGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.3.1 |
Switch Basic Config notifications |
Status: current |
Access: read-only |
NOTIFICATION-GROUP |
|
|
|
hpSwitchCdpConfigGroup |
1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.2.2.13 |
A collection of objects for Cisco discovery protocol
mode configurations. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|