HILLSTONE-SYSTEM-MIB

File: HILLSTONE-SYSTEM-MIB.mib (4045 bytes)

Imported modules

SNMPv2-SMI RFC1155-SMI SNMPv2-TC
HILLSTONE-SMI

Imported symbols

MODULE-IDENTITY NetworkAddress IpAddress
Counter Gauge TimeTicks
Gauge32 TruthValue hillstoneSys

Defined Types

DisplayString  
OCTET STRING    

Defined Values

hillstoneSysMibObjects 1.3.6.1.4.1.28557.2.2.1
OBJECT IDENTIFIER    

sysSerialNumber 1.3.6.1.4.1.28557.2.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sysSoftware 1.3.6.1.4.1.28557.2.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sysCPU 1.3.6.1.4.1.28557.2.2.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysTotalMemory 1.3.6.1.4.1.28557.2.2.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge32  

sysCurMemory 1.3.6.1.4.1.28557.2.2.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge32  

sysTotalSession 1.3.6.1.4.1.28557.2.2.1.6
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sysCurSession 1.3.6.1.4.1.28557.2.2.1.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge32  

sysHAStatus 1.3.6.1.4.1.28557.2.2.1.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(0), init(1), hello(2), backup(3), master(4), slase(5), aa-mode(6)  

sysSnmpStackStatus 1.3.6.1.4.1.28557.2.2.1.9
The running status of snmp Stack.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sysTr069StackStatus 1.3.6.1.4.1.28557.2.2.1.10
The running status of tr069 stack.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sysVedorOUI 1.3.6.1.4.1.28557.2.2.1.11
The oui code of the Tr069 stack..
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysLogStackStatus 1.3.6.1.4.1.28557.2.2.1.12
The running status of syslog stack.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sysLogServerAddress1 1.3.6.1.4.1.28557.2.2.1.13
The syslog receiver addrees 1.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysLogServerAddress2 1.3.6.1.4.1.28557.2.2.1.14
The syslog receiver addrees 2.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysDeviceReloadAction 1.3.6.1.4.1.28557.2.2.1.15
The actioin of reloading the device. when the value is set to 2,the device will reboot at once.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER reloadUnAvailable(1), reloadAtOnce(2)  

sysStatisticsPeriod 1.3.6.1.4.1.28557.2.2.1.16
The period of statistics. default statistics period is 24hours
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oneDay(1)