HH3C-TRANSCEIVER-INFO-MIB

File: HH3C-TRANSCEIVER-INFO-MIB.mib (24508 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IF-MIB
HH3C-OID-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
TruthValue ifIndex hh3cCommon

Defined Types

Hh3cTransceiverInfoEntry  
SEQUENCE    
  hh3cTransceiverHardwareType OCTET STRING
  hh3cTransceiverType OCTET STRING
  hh3cTransceiverWaveLength Integer32
  hh3cTransceiverVendorName OCTET STRING
  hh3cTransceiverSerialNumber OCTET STRING
  hh3cTransceiverFiberDiameterType INTEGER
  hh3cTransceiverTransferDistance Integer32
  hh3cTransceiverDiagnostic TruthValue
  hh3cTransceiverCurTXPower Integer32
  hh3cTransceiverMaxTXPower Integer32
  hh3cTransceiverMinTXPower Integer32
  hh3cTransceiverCurRXPower Integer32
  hh3cTransceiverMaxRXPower Integer32
  hh3cTransceiverMinRXPower Integer32
  hh3cTransceiverTemperature Integer32
  hh3cTransceiverVoltage Integer32
  hh3cTransceiverBiasCurrent Integer32
  hh3cTransceiverTempHiAlarm Integer32
  hh3cTransceiverTempLoAlarm Integer32
  hh3cTransceiverTempHiWarn Integer32
  hh3cTransceiverTempLoWarn Integer32
  hh3cTransceiverVccHiAlarm Integer32
  hh3cTransceiverVccLoAlarm Integer32
  hh3cTransceiverVccHiWarn Integer32
  hh3cTransceiverVccLoWarn Integer32
  hh3cTransceiverBiasHiAlarm Integer32
  hh3cTransceiverBiasLoAlarm Integer32
  hh3cTransceiverBiasHiWarn Integer32
  hh3cTransceiverBiasLoWarn Integer32
  hh3cTransceiverPwrOutHiAlarm Integer32
  hh3cTransceiverPwrOutLoAlarm Integer32
  hh3cTransceiverPwrOutHiWarn Integer32
  hh3cTransceiverPwrOutLoWarn Integer32
  hh3cTransceiverRcvPwrHiAlarm Integer32
  hh3cTransceiverRcvPwrLoAlarm Integer32
  hh3cTransceiverRcvPwrHiWarn Integer32
  hh3cTransceiverRcvPwrLoWarn Integer32
  hh3cTransceiverErrors BITS
  hh3cTransceiverVendorOUI OCTET STRING
  hh3cTransceiverRevisionNumber OCTET STRING

Hh3cTransceiverChannelEntry  
SEQUENCE    
  hh3cTransceiverChannelIndex Integer32
  hh3cTransceiverChannelCurTXPower Integer32
  hh3cTransceiverChannelCurRXPower Integer32
  hh3cTransceiverChannelTemperature Integer32
  hh3cTransceiverChannelBiasCurrent Integer32

Defined Values

hh3cTransceiver 1.3.6.1.4.1.25506.2.70
The objects in this MIB module are used to display the information of transceiver on interface.
MODULE-IDENTITY    

hh3cTransceiverInfoAdm 1.3.6.1.4.1.25506.2.70.1
OBJECT IDENTIFIER    

hh3cTransceiverInfoTable 1.3.6.1.4.1.25506.2.70.1.1
This table shows transceiver information on an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cTransceiverInfoEntry

hh3cTransceiverInfoEntry 1.3.6.1.4.1.25506.2.70.1.1.1
The entry of the hh3cTransceiverInfoTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cTransceiverInfoEntry  

hh3cTransceiverHardwareType 1.3.6.1.4.1.25506.2.70.1.1.1.1
Hardware type of the interface, such as SM(single mode).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hh3cTransceiverType 1.3.6.1.4.1.25506.2.70.1.1.1.2
Type of the interface, such as SFP/XFP/GBIC.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hh3cTransceiverWaveLength 1.3.6.1.4.1.25506.2.70.1.1.1.3
Wave length of the interface, measured in nanometer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverVendorName 1.3.6.1.4.1.25506.2.70.1.1.1.4
Vendor name of the interface.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hh3cTransceiverSerialNumber 1.3.6.1.4.1.25506.2.70.1.1.1.5
Serial number of the interface.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hh3cTransceiverFiberDiameterType 1.3.6.1.4.1.25506.2.70.1.1.1.6
The diameter of the fiber, measured in micron. fiber9 - 9 micron multi-mode fiber fiber50 - 50 micron multi-mode fiber fiber625 - 62.5 micron multi-mode fiber copper - copper cable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fiber9(1), fiber50(2), fiber625(3), copper(4), unknown(65535)  

hh3cTransceiverTransferDistance 1.3.6.1.4.1.25506.2.70.1.1.1.7
The maximum distance which the interface can transmit, measured in meter.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverDiagnostic 1.3.6.1.4.1.25506.2.70.1.1.1.8
Indicating the digital diagnostic monitoring function.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hh3cTransceiverCurTXPower 1.3.6.1.4.1.25506.2.70.1.1.1.9
Indicating the current transmitted power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverMaxTXPower 1.3.6.1.4.1.25506.2.70.1.1.1.10
Indicating the maximum transmitted power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverMinTXPower 1.3.6.1.4.1.25506.2.70.1.1.1.11
Indicating the minimum transmitted power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverCurRXPower 1.3.6.1.4.1.25506.2.70.1.1.1.12
Indicating the current received power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverMaxRXPower 1.3.6.1.4.1.25506.2.70.1.1.1.13
Indicating the maximum received power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverMinRXPower 1.3.6.1.4.1.25506.2.70.1.1.1.14
Indicating the minimum received power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverTemperature 1.3.6.1.4.1.25506.2.70.1.1.1.15
Indicating the current temperature. The unit is Celsius centigrade.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverVoltage 1.3.6.1.4.1.25506.2.70.1.1.1.16
Indicating the current voltage. The unit is in hundredths of V
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverBiasCurrent 1.3.6.1.4.1.25506.2.70.1.1.1.17
Indicating the current bias electric current. The unit is in hundredths of mA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverTempHiAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.18
Transceiver temperature high alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverTempLoAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.19
Transceiver temperature low alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverTempHiWarn 1.3.6.1.4.1.25506.2.70.1.1.1.20
Transceiver temperature high warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverTempLoWarn 1.3.6.1.4.1.25506.2.70.1.1.1.21
Transceiver temperature low warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverVccHiAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.22
Transceiver VCC high alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverVccLoAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.23
Transceiver VCC low alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverVccHiWarn 1.3.6.1.4.1.25506.2.70.1.1.1.24
Transceiver VCC high warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverVccLoWarn 1.3.6.1.4.1.25506.2.70.1.1.1.25
Transceiver VCC low warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverBiasHiAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.26
Transceiver bias high alarm threshold limit in microamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverBiasLoAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.27
Transceiver bias low alarm threshold limit in microamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverBiasHiWarn 1.3.6.1.4.1.25506.2.70.1.1.1.28
Transceiver bias high warning threshold limit in microamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverBiasLoWarn 1.3.6.1.4.1.25506.2.70.1.1.1.29
Transceiver bias low warning threshold limit in microamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverPwrOutHiAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.30
Transceiver transmit power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverPwrOutLoAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.31
Transceiver transmit power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverPwrOutHiWarn 1.3.6.1.4.1.25506.2.70.1.1.1.32
Transceiver transmit power high warning threshold limit in tenths of microwatts As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverPwrOutLoWarn 1.3.6.1.4.1.25506.2.70.1.1.1.33
Transceiver transmit power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverRcvPwrHiAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.34
Transceiver receive power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverRcvPwrLoAlarm 1.3.6.1.4.1.25506.2.70.1.1.1.35
Transceiver receive power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverRcvPwrHiWarn 1.3.6.1.4.1.25506.2.70.1.1.1.36
Transceiver receive power high warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverRcvPwrLoWarn 1.3.6.1.4.1.25506.2.70.1.1.1.37
Transceiver receive power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverErrors 1.3.6.1.4.1.25506.2.70.1.1.1.38
Bitmask indicating transceiver errors. Transceiver information I/O error(0) Transceiver information checksum error(1) Transceiver type and port configuration mismatch(2) Transceiver type not supported by port hardware(3) WIS local fault(4) Receive optical power fault(5) PMA/PMD receiver local fault(6) PCS receive local fault(7) PHY XS receive local fault(8) Laser bias current fault(9) Laser temperature fault(10) Laser output power fault(11) TX fault(12) PMA/PMD transmitter local fault(13) PCS transmit local fault(14) PHY XS Transmit Local Fault(15) RX loss of signal(16) Unused(17-31)
Status: current Access: read-only
OBJECT-TYPE    
  BITS xcvrIOError(0), xcvrChecksum(1), xcvrTypeAndPortConfigMismatch(2), xcvrTypeNotSupported(3), wisLocalFault(4), rcvOpticalPowerFault(5), pmapmdReceiverLocalFault(6), pcsReceiveLocalFault(7), phyXSReceiveLocalFault(8), laserBiasCurrentFault(9), laserTemperatureFault(10), laserOutputPowerFault(11), txFault(12), pmapmdTransmitterLocalFault(13), pcsTransmitLocalFault(14), phyXSTransmitLocalFault(15), rxLossOfSignal(16)  

hh3cTransceiverVendorOUI 1.3.6.1.4.1.25506.2.70.1.1.1.39
Vendor OUI of the interface.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

hh3cTransceiverRevisionNumber 1.3.6.1.4.1.25506.2.70.1.1.1.40
Revision number of the interface.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

hh3cTransceiverChannelTable 1.3.6.1.4.1.25506.2.70.1.2
This table provides statistics about transceiver with multi-channel.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cTransceiverChannelEntry

hh3cTransceiverChannelEntry 1.3.6.1.4.1.25506.2.70.1.2.1
The entry of the hh3cTransceiverChannelTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cTransceiverChannelEntry  

hh3cTransceiverChannelIndex 1.3.6.1.4.1.25506.2.70.1.2.1.1
The channel index of transceiver. Indicating one channel of the interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

hh3cTransceiverChannelCurTXPower 1.3.6.1.4.1.25506.2.70.1.2.1.2
Indicating the current transmission power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverChannelCurRXPower 1.3.6.1.4.1.25506.2.70.1.2.1.3
Indicating the current received power. The unit is in hundredths of dBM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverChannelTemperature 1.3.6.1.4.1.25506.2.70.1.2.1.4
Indicating the current temperature. The unit is Celsius centigrade.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cTransceiverChannelBiasCurrent 1.3.6.1.4.1.25506.2.70.1.2.1.5
Indicating the current bias electric current. The unit is in hundredths of mA.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32