HH3C-STORAGE-MIB
File:
HH3C-STORAGE-MIB.mib (33141 bytes)
Imported modules
Imported symbols
Defined Types
Hh3cStorageInterfaceEntry |
|
SEQUENCE |
|
|
|
|
hh3cStorageInterfaceIndex |
Integer32 |
|
|
hh3cStorageInterfaceGateway |
InetAddress |
|
|
hh3cStorageInterfaceGatewayType |
InetAddressType |
|
|
hh3cStorageInterfaceMTU |
INTEGER |
|
Hh3cBondingEntry |
|
SEQUENCE |
|
|
|
|
hh3cBondingIndex |
Integer32 |
|
|
hh3cBondingPortList |
OCTET STRING |
|
Hh3cScsiAdapterEntry |
|
SEQUENCE |
|
|
|
|
hh3cAdapterNumber |
Integer32 |
|
|
hh3cAdapterDesc |
OCTET STRING |
|
|
hh3cAdapterType |
INTEGER |
|
|
hh3cFcAdapterMode |
INTEGER |
|
|
hh3cFcAdapterInitiatorWwpnName |
Hh3cWwpnListType |
|
|
hh3cFcAdapterTargetWwpnName |
Hh3cWwpnListType |
|
|
hh3cFcAdapterPortState |
INTEGER |
|
|
hh3cFcAdapterModeSwitch |
Hh3cStorageEnableState |
|
Hh3cExtVoltageEntry |
|
SEQUENCE |
|
|
|
|
hh3cExtVoltagePhysicalIndex |
PhysicalIndex |
|
|
hh3cExtVoltagePhysicalName |
SnmpAdminString |
|
|
hh3cExtVoltage |
Integer32 |
|
|
hh3cExtVoltageLowThreshold |
Integer32 |
|
|
hh3cExtVoltageHighThreshold |
Integer32 |
|
|
hh3cExtCriticalVoltageLowThreshold |
Integer32 |
|
|
hh3cExtCriticalVoltageHighThreshold |
Integer32 |
|
|
hh3cExtShutdownVoltageLowThreshold |
Integer32 |
|
|
hh3cExtShutdownVoltageHighThreshold |
Integer32 |
|
Defined Values
hh3cStorageMIB |
1.3.6.1.4.1.25506.10.1 |
This MIB describes the general information of storage device,
such as the property, configuration and management. |
MODULE-IDENTITY |
|
|
|
hh3cAdaptiveRepCapability |
1.3.6.1.4.1.25506.10.1.1.1.1.4 |
This object identifies if the agent support adaptive replication.
With adaptive replication option, data from the primary resource is continuously
replicated to a replication resource unless the system determines it is not practical
or possible, such as when there is insufficient bandwidth.
For continuous replication to occur, a continuous replication resource is used to
stage the data being replicated from the primary resource.
Similar to a cache, as soon as data comes into the continuous replication resource,
it is written to the replication resource. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Hh3cStorageCapableState |
|
|
hh3cServerPowerState |
1.3.6.1.4.1.25506.10.1.1.1.3.4 |
This object identifies the state of power supply in the server,
and is valid when UPS has been configured successful.
The value 'online' means power supply is well-balanced.
The value 'onlinebypass' means supply power without ups.
The value 'onbattery' means supply power with battery.
The value 'unknown' means the power supply state is unknown. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
online(1), onlinebypass(2), onbattery(3), unknown(4) |
|
hh3cDeuTable |
1.3.6.1.4.1.25506.10.1.1.2.1 |
This table contains some information of a particular DEU(Disk Enclosure
Unit). |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Hh3cDeuEntry |
|
hh3cDeuEntry |
1.3.6.1.4.1.25506.10.1.1.2.1.1 |
An entry containing management information applicable
to a particular DEU. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Hh3cDeuEntry |
|
|
hh3cDeuIndex |
1.3.6.1.4.1.25506.10.1.1.2.1.1.1 |
This object identifies the index of hh3cDeuTable. The DEU identified
by a particular value of this index is the same object as identified
by the same value of entPhysicalIndex. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cDeuDiskScan |
1.3.6.1.4.1.25506.10.1.1.2.1.1.3 |
The operation of scanning the table. When the value of this object
is set to 'action', the operation of disk scanning is touched off. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Hh3cStorageActionType |
|
|
hh3cStorageInterfaceEntry |
1.3.6.1.4.1.25506.10.1.1.2.2.1 |
An entry containing management information applicable
to a particular interface. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Hh3cStorageInterfaceEntry |
|
|
hh3cStorageInterfaceIndex |
1.3.6.1.4.1.25506.10.1.1.2.2.1.1 |
This object identifies the index of Hh3cStorageInterfaceEntry. The
interface identified by this index is the same interface as identified
by the same value of ifIndex. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cStorageInterfaceMTU |
1.3.6.1.4.1.25506.10.1.1.2.2.1.4 |
This object identifies the MTU of interface. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
mtu1(1500), mtu2(9000) |
|
hh3cBondingTable |
1.3.6.1.4.1.25506.10.1.1.2.3 |
This table describes the information of the Bonding interface. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Hh3cBondingEntry |
|
hh3cBondingEntry |
1.3.6.1.4.1.25506.10.1.1.2.3.1 |
An entry containing management information applicable to a particular
Bonding interface. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Hh3cBondingEntry |
|
|
hh3cBondingIndex |
1.3.6.1.4.1.25506.10.1.1.2.3.1.1 |
This object identifies the index of hh3cBondingEntry. The interface
identified by this index is the same interface as identified by the
same value of ifIndex. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cBondingPortList |
1.3.6.1.4.1.25506.10.1.1.2.3.1.2 |
An entry contains management information applicable to a particular bonding interface.
Every two bytes describe the ifIndex of an interface, and an interface belongs
to one bonding group only. An interface should be deleted from the portlist
of the bonding group it belongs to before it is added to another bonding group. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hh3cScsiAdapterTable |
1.3.6.1.4.1.25506.10.1.1.2.4 |
This table containing some information of the SCSI(Small Computer
System interface) adapter. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Hh3cScsiAdapterEntry |
|
hh3cScsiAdapterEntry |
1.3.6.1.4.1.25506.10.1.1.2.4.1 |
An entry containing management information applicable
to a particular SCSI adapter. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Hh3cScsiAdapterEntry |
|
|
hh3cAdapterNumber |
1.3.6.1.4.1.25506.10.1.1.2.4.1.1 |
This object identifies the index of the adapter . |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cAdapterDesc |
1.3.6.1.4.1.25506.10.1.1.2.4.1.2 |
This object describes some information of the adapter. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hh3cAdapterType |
1.3.6.1.4.1.25506.10.1.1.2.4.1.3 |
This object identifies the type of adapter. If the value of this
object is not equal to 'fc', the associated object(such as hh3cFcAdapterMode,
hh3cFcAdapterIWWPNs,hh3cFcAdapterTWWPNs,hh3cFcAdapterPortState,hh3cFcAdapterModeSwitch)
will be invalid. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
scsi(1), fc(2) |
|
hh3cFcAdapterMode |
1.3.6.1.4.1.25506.10.1.1.2.4.1.4 |
This object identifies the mode type of adapter. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
initiator(1), target(2), dual(3) |
|
hh3cFcAdapterPortState |
1.3.6.1.4.1.25506.10.1.1.2.4.1.7 |
This object identifies the state of adapter's interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
linkup(1), linkdown(2) |
|
hh3cExtVoltageTable |
1.3.6.1.4.1.25506.10.1.1.2.5 |
This table contains some entity extend information of the voltage. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Hh3cExtVoltageEntry |
|
hh3cExtVoltageEntry |
1.3.6.1.4.1.25506.10.1.1.2.5.1 |
An entry containing management information applicable to the voltage. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Hh3cExtVoltageEntry |
|
|
hh3cExtVoltage |
1.3.6.1.4.1.25506.10.1.1.2.5.1.3 |
The voltage for the entity. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cExtVoltageLowThreshold |
1.3.6.1.4.1.25506.10.1.1.2.5.1.4 |
The low-threshold for the voltage.
When voltage is lower than low-threshold, a notification will be
sent. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cExtVoltageHighThreshold |
1.3.6.1.4.1.25506.10.1.1.2.5.1.5 |
The high-threshold for the voltage.
When voltage is higher than high-threshold, a notification will be
sent. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cExtCriticalVoltageLowThreshold |
1.3.6.1.4.1.25506.10.1.1.2.5.1.6 |
The critical low threshold for voltage.
If the voltage is lower too much than the entity needs,
the entity will halt. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cExtCriticalVoltageHighThreshold |
1.3.6.1.4.1.25506.10.1.1.2.5.1.7 |
The critical high threshold for voltage.
If the voltage is higher too much than the entity needs,
the entity will halt. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cExtShutdownVoltageLowThreshold |
1.3.6.1.4.1.25506.10.1.1.2.5.1.8 |
The voltage is lower than the critical low threshold.
If the voltage is lower too much than the entity needs,
the entity halts now. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cExtShutdownVoltageHighThreshold |
1.3.6.1.4.1.25506.10.1.1.2.5.1.9 |
The voltage is higher than the critical high threshold.
If the voltage is higher too much than the entity needs,
the entity halts now. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hh3cStorCriticalLowerTemperatureThresholdNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.1 |
The hh3cStorCriticalLowerTemperatureThresholdNotification indicates
the temperature is lower than the threshold.
If the temperature is lower too much than the entity needs,
the entity will halt. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cExtVoltageLowThresholdNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.3 |
The hh3cExtVoltageLowThresholdNotification indicates
the Voltage is lower than the low-threshold. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cExtVoltageHighThresholdNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.4 |
The hh3cExtVoltageHighThresholdNotification indicates
the Voltage is lower than the high-threshold. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cExtCriticalVoltageLowThresholdNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.5 |
The hh3cExtCriticalVoltageLowThresholdNotification indicates
the Voltage is lower than the critical low threshold. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cExtCriticalVoltageHighThresholdNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.6 |
The hh3cExtCriticalVoltageHighThresholdNotification indicates
the Voltage is higher than the critical high threshold. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cExtVoltageTooHigh |
1.3.6.1.4.1.25506.10.1.1.3.0.8 |
The hh3cExtVoltageTooHighNotification indicates
the Voltage is higher than the critical high threshold,
and the entity halt now! |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cExtBatteryStateNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.9 |
The hh3cExtBatteryStateNotification indicates
the raid battery entity's state changes. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cDiskIOErrorNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.10 |
The hh3cDiskIOErrorNotification indicates that a disk occurred I/O error. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidCreateNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.11 |
The hh3cRaidCreateNotification indicates that a array is created. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidDeleteNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.12 |
The hh3cRaidDeleteStateNotification indicates that a array is deleted. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidHideStateNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.13 |
The hh3cRaidFailedNotification indicates that a array hide or unhide. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidRunStateNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.14 |
The hh3cRaidDegradeNotification indicates that a array state change. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidImportNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.15 |
The hh3cRaidFailedNotification indicates that a thrid array is imported. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidRebuildStartNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.16 |
The hh3cRaidRebuildStartNotification indicates that
a array start to rebuild. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidRebuildFinishNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.17 |
The hh3cRaidRebuildStartNotification indicates that
a array fininsh rebuild. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidRebuildPauseNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.18 |
The hh3cRaidRebuildPauseNotification indicates that
pause a array rebuilding. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidRebuildInterruptNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.19 |
The hh3cRaidRebuildInterruptNotification indicates that
interrupt a array rebuilding. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cSoftwareModuleFailNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.20 |
The hh3cSoftwareModuleFailNotification indicates that software module(s) fail. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidBatteryExpiredNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.21 |
The hh3cRaidBatteryExpiredNotification indicates
RAID Battery lifetime had expired. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidBatteryWillExpireNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.22 |
The hh3cRaidBatteryWillExpireNotification indicates
RAID Battery lifetime will expire. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cLvOnlineFailNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.23 |
The hh3cLvOnlineFailNotification indicates lv(s) on vd fail to online. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cLvOfflineFailNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.24 |
The hh3cLvOfflineFailNotification indicates lv(s) on vd fail to offline. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cRaidRunNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.25 |
The hh3cRaidRunNotification indicates that a array is running. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cExtVoltageNormal |
1.3.6.1.4.1.25506.10.1.1.3.0.26 |
The hh3cStorVoltageRecoveryNotification indicates
the Voltage has recovered in reference. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cDiskPowerOnNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.27 |
The hh3cDiskPowerOnNotification indicates that
a disk is power on. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hh3cDiskPowerOffNotification |
1.3.6.1.4.1.25506.10.1.1.3.0.28 |
The hh3cDiskPowerOffNotification indicates that
a disk is power off. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|