HH3C-RDDC-MIB

File: HH3C-RDDC-MIB.mib (9766 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IF-MIB
HH3C-OID-MIB

Imported symbols

Unsigned32 Integer32 OBJECT-TYPE
MODULE-IDENTITY NOTIFICATION-TYPE DisplayString
ifIndex ifDescr hh3cCommon

Defined Types

Hh3cRddcEntry  
SEQUENCE    
  hh3cRddcGroupIdx Unsigned32
  hh3cRddcGroupName OCTET STRING
  hh3cRddcPreempTimeRemain Unsigned32
  hh3cRddcPreempTimeConfig Unsigned32
  hh3cRddcHoldTimeRemain Unsigned32
  hh3cRddcHoldTimeConfig Unsigned32

Hh3cRddcNodeEntry  
SEQUENCE    
  hh3cRddcNodeGroupIdx Unsigned32
  hh3cRddcNodeId Unsigned32
  hh3cRddcNodeBindType INTEGER
  hh3cRddcNodeBindInfo Unsigned32
  hh3cRddcNodePriority Unsigned32
  hh3cRddcNodeWeight Integer32
  hh3cRddcNodeStatus INTEGER

Defined Values

hh3cRddc 1.3.6.1.4.1.25506.2.151
Redundancy group is concerned with ensuring minimal disruption to data and control planes in case of a failover. If one of the group-node in an IRF fails, the other group-node in the IRF takes over the function of the failed group-node with minimal service interruption. This module defines the objects pertaining to redundancy group(RDDC).
MODULE-IDENTITY    

hh3cRddcNotifications 1.3.6.1.4.1.25506.2.151.0
OBJECT IDENTIFIER    

hh3cRddcObjects 1.3.6.1.4.1.25506.2.151.1
OBJECT IDENTIFIER    

hh3cRddcInfo 1.3.6.1.4.1.25506.2.151.1.1
OBJECT IDENTIFIER    

hh3cRddcTrapObjects 1.3.6.1.4.1.25506.2.151.1.2
OBJECT IDENTIFIER    

hh3cRddcTable 1.3.6.1.4.1.25506.2.151.1.1.1
This table describes the current status of redundancy groups.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cRddcEntry

hh3cRddcEntry 1.3.6.1.4.1.25506.2.151.1.1.1.1
The entry of hh3cRddcEntry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cRddcEntry  

hh3cRddcGroupIdx 1.3.6.1.4.1.25506.2.151.1.1.1.1.1
Unique identifier of this redundancy group. 0 is an invalid value.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32  

hh3cRddcGroupName 1.3.6.1.4.1.25506.2.151.1.1.1.1.2
Unique identifier of this redundancy group.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..16)  

hh3cRddcPreempTimeRemain 1.3.6.1.4.1.25506.2.151.1.1.1.1.3
The redundancy group should not switch back immediately when a failover is recovered. The preempt delay timer is started for waiting the failover became believable. This object contains the current preempt delay time remained when a failover is recovered.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hh3cRddcPreempTimeConfig 1.3.6.1.4.1.25506.2.151.1.1.1.1.4
The current preempt delay time.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hh3cRddcHoldTimeRemain 1.3.6.1.4.1.25506.2.151.1.1.1.1.5
To prevent frequent switchovers of the redundancy group, the hold-down timer started to keeping in a state for a fixed time. This object contains the current remained hold-down time when a switchover or a failover recovery occurred.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hh3cRddcHoldTimeConfig 1.3.6.1.4.1.25506.2.151.1.1.1.1.6
The current hold-down time.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hh3cRddcNodeTable 1.3.6.1.4.1.25506.2.151.1.1.2
This table describes the current status of a redundancy group node.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cRddcNodeEntry

hh3cRddcNodeEntry 1.3.6.1.4.1.25506.2.151.1.1.2.1
The entry of hh3cRddcNodeEntry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cRddcNodeEntry  

hh3cRddcNodeGroupIdx 1.3.6.1.4.1.25506.2.151.1.1.2.1.1
Unique identifier of this redundancy group. 0 is an invalid value.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

hh3cRddcNodeId 1.3.6.1.4.1.25506.2.151.1.1.2.1.2
Unique identifier of this redundancy group node. 0 is an invalid value.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

hh3cRddcNodeBindType 1.3.6.1.4.1.25506.2.151.1.1.2.1.3
The bind type of this redundancy group node. The current version only supports binding chassis of an IRF device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER invalid(1), chassis(2)  

hh3cRddcNodeBindInfo 1.3.6.1.4.1.25506.2.151.1.1.2.1.4
The bind information of this redundancy group node. The current version only supports binding chassis of an IRF device. If the value of hh3cRddcNodeBindType is invalid, the value of hh3cRddcNodeBindInfo is 65535.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hh3cRddcNodePriority 1.3.6.1.4.1.25506.2.151.1.1.2.1.5
The priority of this redundancy group node. The higher the value, the greater the priority.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..255  

hh3cRddcNodeWeight 1.3.6.1.4.1.25506.2.151.1.1.2.1.6
The current weight of this redundancy group node. The max value is 255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cRddcNodeStatus 1.3.6.1.4.1.25506.2.151.1.1.2.1.7
The current status of this redundancy group node.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER invalid(1), master(2), standby(3)  

hh3cRddcNodeInfo 1.3.6.1.4.1.25506.2.151.1.2.1
This object contains node identification information where the switchover occurred.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..255)  

hh3cRddcSwitchReason 1.3.6.1.4.1.25506.2.151.1.2.2
This object contains the cause for switchover.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..255)  

hh3cRddcSwitchoverTrap 1.3.6.1.4.1.25506.2.151.0.1
Notification to signal switchover/failover.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hh3cRddcFailIfRecoverTrap 1.3.6.1.4.1.25506.2.151.0.2
Notification to signal the failed interface recovered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hh3cRddcFailIfGenerateTrap 1.3.6.1.4.1.25506.2.151.0.3
Notification to signal the failed interface generated.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE