File: GUDEADS-EPC8X-MIB.mib (11300 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF

Imported symbols

enterprises MODULE-IDENTITY OBJECT-TYPE
NOTIFICATION-TYPE Counter32 Integer32
IpAddress OBJECT-GROUP NOTIFICATION-GROUP

Defined Types

Epc8TrapIPEntry  
SEQUENCE    
  epc8TrapIPIndex Integer32
  epc8TrapIPAddr IpAddress
  epc8TrapIPPort Integer32

Epc8SensorEntry  
SEQUENCE    
  epc8SensorIndex Integer32
  epc8TempSensor Integer32
  epc8HygroSensor Integer32

Epc8portEntry  
SEQUENCE    
  epc8PortIndex Integer32
  epc8PortName OCTET STRING
  epc8PortState INTEGER
  epc8PortSwitchCount Counter32
  epc8PortStartupMode INTEGER
  epc8PortStartupDelay Integer32
  epc8PortRepowerTime Integer32

Defined Values

gudeads 1.3.6.1.4.1.28507
Tok_String
MODULE-IDENTITY    

events 1.3.6.1.4.1.28507.1.0
OBJECT IDENTIFIER    

epc8TrapIPTable 1.3.6.1.4.1.28507.1.1.1.2
list of all Trap receiver
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Epc8TrapIPEntry

gadsEPC8 1.3.6.1.4.1.28507.1
OBJECT IDENTIFIER    

epc8TrapIPEntry 1.3.6.1.4.1.28507.1.1.1.2.1
an entry containing management informations regarding the list of trap receivers
Status: current Access: not-accessible
OBJECT-TYPE    
  Epc8TrapIPEntry  

epc8TrapIPIndex 1.3.6.1.4.1.28507.1.1.1.2.1.1
A unique value, greater than zero, for each receiver slot.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

epc8TrapIPPort 1.3.6.1.4.1.28507.1.1.1.2.1.3
IP Port specifying one Trap receiver slot. A value of 0 disables this slot.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1024  

epc8portNumber 1.3.6.1.4.1.28507.1.1.2.1
The number of PowerPorts
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..8  

epc8PortIndex 1.3.6.1.4.1.28507.1.1.2.2.1.1
A unique value, greater than zero, for each PowerPort.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

epc8PortStartupMode 1.3.6.1.4.1.28507.1.1.2.2.1.5
set Mode of startup sequence (off, on , remember last state)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), laststate(2)  

epc8Sensors 1.3.6.1.4.1.28507.1.1.3
OBJECT IDENTIFIER    

epc8Irms 1.3.6.1.4.1.28507.1.1.3.1
actual rms Current, a value of -9999 indicates that data is not available
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

epc8SensorTable 1.3.6.1.4.1.28507.1.1.3.2
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Epc8SensorEntry

epc8SensorEntry 1.3.6.1.4.1.28507.1.1.3.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  Epc8SensorEntry  

epc8SensorIndex 1.3.6.1.4.1.28507.1.1.3.2.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2  

epc8TempSensor 1.3.6.1.4.1.28507.1.1.3.2.1.2
actual temperature, a value of -9999 indicates that data is not available
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

epc8HygroSensor 1.3.6.1.4.1.28507.1.1.3.2.1.3
actual humidity, a value of -9999 indicates that data is not available
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

epcSwitchEvtPort1 1.3.6.1.4.1.28507.1.0.1
Event is triggered when a port is switched
Status: current Access: read-only
NOTIFICATION-TYPE    

epcSwitchEvtPort2 1.3.6.1.4.1.28507.1.0.2
Event is triggered when a port is switched
Status: current Access: read-only
NOTIFICATION-TYPE    

epcSwitchEvtPort3 1.3.6.1.4.1.28507.1.0.3
Event is triggered when a port is switched
Status: current Access: read-only
NOTIFICATION-TYPE    

epcSwitchEvtPort4 1.3.6.1.4.1.28507.1.0.4
Event is triggered when a port is switched
Status: current Access: read-only
NOTIFICATION-TYPE    

epcSwitchEvtPort5 1.3.6.1.4.1.28507.1.0.5
Event is triggered when a port is switched
Status: current Access: read-only
NOTIFICATION-TYPE    

epcSwitchEvtPort6 1.3.6.1.4.1.28507.1.0.6
Event is triggered when a port is switched
Status: current Access: read-only
NOTIFICATION-TYPE    

epcSwitchEvtPort7 1.3.6.1.4.1.28507.1.0.7
Event is triggered when a port is switched
Status: current Access: read-only
NOTIFICATION-TYPE    

epcSwitchEvtPort8 1.3.6.1.4.1.28507.1.0.8
Event is triggered when a port is switched
Status: current Access: read-only
NOTIFICATION-TYPE    

epc8SNMPaccess 1.3.6.1.4.1.28507.1.1.1
OBJECT IDENTIFIER    

epc8TrapCtrl 1.3.6.1.4.1.28507.1.1.1.1
0 = off 1 = Ver. 1 2 = Ver. 2c
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2  

epc8Objects 1.3.6.1.4.1.28507.1.1
OBJECT IDENTIFIER    

epc8powerports 1.3.6.1.4.1.28507.1.1.2
OBJECT IDENTIFIER    

epc8portTable 1.3.6.1.4.1.28507.1.1.2.2
list of all EPC Powerports
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Epc8portEntry

epc8portEntry 1.3.6.1.4.1.28507.1.1.2.2.1
An entry containing management information applicable to a particular powerport.
Status: current Access: not-accessible
OBJECT-TYPE    
  Epc8portEntry  

epc8PortName 1.3.6.1.4.1.28507.1.1.2.2.1.2
A textual string containing name of a PowerPort.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..15)  

epc8PortState 1.3.6.1.4.1.28507.1.1.2.2.1.3
current state a PowerPort
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

epc8PortStartupDelay 1.3.6.1.4.1.28507.1.1.2.2.1.6
Delay in sec for startup action
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

epc8PortRepowerTime 1.3.6.1.4.1.28507.1.1.2.2.1.7
Delay in sec for repower port after switching off
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

epc8PortSwitchCount 1.3.6.1.4.1.28507.1.1.2.2.1.4
The total number of switch actions ocurred on a PowerPort. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

epc8TrapIPAddr 1.3.6.1.4.1.28507.1.1.1.2.1.2
IP Address specifying one Trap receiver slot. A value of '00000000'H disables this slot.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

epc8Conf 1.3.6.1.4.1.28507.1.3
OBJECT IDENTIFIER    

epc8Groups 1.3.6.1.4.1.28507.1.3.1
OBJECT IDENTIFIER    

epc8Compls 1.3.6.1.4.1.28507.1.3.2
OBJECT IDENTIFIER    

epc8TempEvtSen1 1.3.6.1.4.1.28507.1.0.9
temperature limits exceeded
Status: current Access: read-write
NOTIFICATION-TYPE    

epc8TempEvtSen2 1.3.6.1.4.1.28507.1.0.10
temperature limits exceeded
Status: current Access: read-write
NOTIFICATION-TYPE    

epc8HygroEvtSen1 1.3.6.1.4.1.28507.1.0.11
hygro limits exceeded
Status: current Access: read-write
NOTIFICATION-TYPE    

epc8HygroEvtSen2 1.3.6.1.4.1.28507.1.0.12
hygro limits exceeded
Status: current Access: read-write
NOTIFICATION-TYPE    

epc8BasicGroup 1.3.6.1.4.1.28507.1.3.1.1
Basic objects.
Status: current Access: read-write
OBJECT-GROUP    

epc8NotificationGroup 1.3.6.1.4.1.28507.1.3.1.2
Tok_String
Status: current Access: read-write
NOTIFICATION-GROUP