Defined Types
Epc2x6TrapIPEntry |
|
SEQUENCE |
|
|
|
|
epc2x6TrapIPIndex |
Integer32 |
|
|
epc2x6TrapIPAddr |
IpAddress |
|
|
epc2x6TrapIPPort |
Integer32 |
|
Epc2x6portEntry |
|
SEQUENCE |
|
|
|
|
epc2x6PortIndex |
Integer32 |
|
|
epc2x6PortName |
OCTET STRING |
|
|
epc2x6PortState |
INTEGER |
|
|
epc2x6PortSwitchCount |
Counter32 |
|
|
epc2x6PortStartupMode |
INTEGER |
|
|
epc2x6PortStartupDelay |
Integer32 |
|
|
epc2x6PortRepowerTime |
Integer32 |
|
Defined Values
gudeads |
1.3.6.1.4.1.28507 |
Tok_String |
MODULE-IDENTITY |
|
|
|
epc2x6portFuses |
1.3.6.1.4.1.28507.6.1.2.3 |
Bit State of Fuses (Bit 0 = Fuse1, Bit 1 = Fuse2) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..3 |
|
epc2x6Temperature |
1.3.6.1.4.1.28507.6.1.3 |
actual Temperature, if sensor is not supported
'9998', not connected '9999' is given back as
result |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
epc2x6witchEvt1 |
1.3.6.1.4.1.28507.0.1 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt2 |
1.3.6.1.4.1.28507.0.2 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt3 |
1.3.6.1.4.1.28507.0.3 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt4 |
1.3.6.1.4.1.28507.0.4 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt5 |
1.3.6.1.4.1.28507.0.5 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt6 |
1.3.6.1.4.1.28507.0.6 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt7 |
1.3.6.1.4.1.28507.0.7 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt8 |
1.3.6.1.4.1.28507.0.8 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt9 |
1.3.6.1.4.1.28507.0.9 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt10 |
1.3.6.1.4.1.28507.0.10 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt11 |
1.3.6.1.4.1.28507.0.11 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
epc2x6witchEvt12 |
1.3.6.1.4.1.28507.0.12 |
Event is triggered when |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
events |
1.3.6.1.4.1.28507.0 |
OBJECT IDENTIFIER |
|
|
|
epc2x6TrapCtrl |
1.3.6.1.4.1.28507.6.1.1.1 |
0 = off
1 = Ver. 1
2 = Ver. 2c |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2 |
|
epc2x6TrapIPEntry |
1.3.6.1.4.1.28507.6.1.1.2.1 |
an entry containing management
informations regarding the list of trap
receivers |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Epc2x6TrapIPEntry |
|
|
epc2x6TrapIPIndex |
1.3.6.1.4.1.28507.6.1.1.2.1.1 |
A unique value, greater than zero, for each receiver slot. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..8 |
|
epc2x6TrapIPPort |
1.3.6.1.4.1.28507.6.1.1.2.1.3 |
IP Port specifying one Trap receiver slot.
A value of 0 disables this slot. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..1024 |
|
epc2x6portNumber |
1.3.6.1.4.1.28507.6.1.2.1 |
The number of PowerPorts |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..12 |
|
epc2x6portEntry |
1.3.6.1.4.1.28507.6.1.2.2.1 |
An entry containing management information applicable to a
particular powerport. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Epc2x6portEntry |
|
|
epc2x6PortIndex |
1.3.6.1.4.1.28507.6.1.2.2.1.1 |
A unique value, greater than zero, for each PowerPort. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..12 |
|
epc2x6PortName |
1.3.6.1.4.1.28507.6.1.2.2.1.2 |
A textual string containing name of a PowerPort. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..15) |
|
epc2x6PortState |
1.3.6.1.4.1.28507.6.1.2.2.1.3 |
current state a PowerPort |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(0), on(1) |
|
epc2x6PortSwitchCount |
1.3.6.1.4.1.28507.6.1.2.2.1.4 |
The total number of switch actions ocurred on a PowerPort.
Does not count switch commands which will not switch
the ralay state, so just real relay switches are displayed here. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
epc2x6Conf |
1.3.6.1.4.1.28507.6.3 |
OBJECT IDENTIFIER |
|
|
|
epc2x6BasicGroup |
1.3.6.1.4.1.28507.6.3.1.1 |
Basic objects. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
epc2x6TrapIPAddr |
1.3.6.1.4.1.28507.6.1.1.2.1.2 |
IP Address specifying one Trap receiver slot.
A value of '00000000'H disables this slot. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
epc2x6PortStartupMode |
1.3.6.1.4.1.28507.6.1.2.2.1.5 |
set Mode of startup sequence (off, on , remember last state) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(0), on(1), laststate(2) |
|
epc2x6PortRepowerTime |
1.3.6.1.4.1.28507.6.1.2.2.1.7 |
Delay in sec for repower port after switching off |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..65535 |
|
epc2x6FuseEvt |
1.3.6.1.4.1.28507.0.13 |
Tok_String |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
epc2x6TempEvt |
1.3.6.1.4.1.28507.0.14 |
change of temperature |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|