GDCSC613-MIB

File: GDCSC613-MIB.mib (26638 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
GDCMACRO-MIB

Imported symbols

enterprises DisplayString OBJECT-TYPE
SCinstance

Defined Types

Bql613WhatAreYouEntry  
SEQUENCE    
  bql613WhatAreYouIndex SCinstance
  bql613CodeRev DisplayString
  bql613AlarmStatus OCTET STRING

Bql613ConfigEntry  
SEQUENCE    
  bql613ConfigIndex SCinstance
  bql613TestPattern INTEGER
  bql613RLTimeout INTEGER
  bql613MasterTXClkSrc INTEGER
  bql613DTEDataRate INTEGER
  bql613RespRdl INTEGER

Bql613DiagnosticEntry  
SEQUENCE    
  bql613DiagnosticIndex SCinstance
  bql613DiagnosticTest INTEGER
  bql613DiagnosticActive INTEGER
  bql613DiagnosticResults INTEGER
  bql613DiagnosticErrorCount INTEGER

Bql613AlarmConfigEntry  
SEQUENCE    
  bql613AlarmConfigIndex SCinstance
  bql613AlarmConfigIdentifier OBJECT IDENTIFIER
  bql613AlarmThreshold INTEGER

Bql613ControlEntry  
SEQUENCE    
  bql613ControlIndex SCinstance
  bql613SoftReset INTEGER
  bql613EraseConfig INTEGER
  bql613FrontPanel INTEGER
  bql613LEDStatus OCTET STRING

Bql613CurrentEntry  
SEQUENCE    
  bql613CurrentIndex SCinstance
  bql613CurrentStats OCTET STRING

Bql613IntervalEntry  
SEQUENCE    
  bql613IntervalIndex SCinstance
  bql613IntervalNumber INTEGER
  bql613IntervalStats OCTET STRING

Bql613TotalEntry  
SEQUENCE    
  bql613TotalIndex SCinstance
  bql613TotalStats OCTET STRING

Bql613IntervalMaintenanceEntry  
SEQUENCE    
  bql613IntervalMaintenanceIndex SCinstance
  bql613ResetIntervals INTEGER
  bql613NumberofValidIntervals INTEGER
  bql613ResetMajorAlarm INTEGER
  bql613ResetMinorAlarm INTEGER

Defined Values

gdc 1.3.6.1.4.1.498
OBJECT IDENTIFIER    

bql2 1.3.6.1.4.1.498.12
OBJECT IDENTIFIER    

bql613 1.3.6.1.4.1.498.12.1
OBJECT IDENTIFIER    

bql613MIBVersion 1.3.6.1.4.1.498.12.1.1
The version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is a minor revision(0-9), z is a typo revision (0-9) and T indicates the MIB is still a test revision(A-Z). When a release is complete no T should exist.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(5)  

bql613WhatAreYouTable 1.3.6.1.4.1.498.12.1.2
The GDC SC613 What Are You Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Bql613WhatAreYouEntry

bql613WhatAreYouEntry 1.3.6.1.4.1.498.12.1.2.1
An entry in the GDC SC613 What Are You table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Bql613WhatAreYouEntry  

bql613WhatAreYouIndex 1.3.6.1.4.1.498.12.1.2.1.1
This object is the identifier of the SC613 What Are You table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

bql613CodeRev 1.3.6.1.4.1.498.12.1.2.1.2
This function returns the firmware code level. Example A- ,B-
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

bql613AlarmStatus 1.3.6.1.4.1.498.12.1.2.1.3
The current alarms of the unit without the alarm masks.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

bql613ConfigTable 1.3.6.1.4.1.498.12.1.3
The GDC SC613.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Bql613ConfigEntry

bql613ConfigEntry 1.3.6.1.4.1.498.12.1.3.1
A listing of GDC 2B1Q SC613 options.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Bql613ConfigEntry  

bql613ConfigIndex 1.3.6.1.4.1.498.12.1.3.1.1
A unique index for the Configuration Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

bql613TestPattern 1.3.6.1.4.1.498.12.1.3.1.2
Object to select loop and channel test pattern for SC613.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pattern2047(1), pattern511(2)  

bql613RLTimeout 1.3.6.1.4.1.498.12.1.3.1.3
Object to select remote loop time out.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noTimeout(1), timeoutAfter10Min(2)  

bql613MasterTXClkSrc 1.3.6.1.4.1.498.12.1.3.1.4
Object to option the Loop master transmit clock source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), external(2)  

bql613DTEDataRate 1.3.6.1.4.1.498.12.1.3.1.5
Object to option a SC613 Loop interface to a K bit per second rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER kBps64000(9), kBps128000(10)  

bql613RespRdl 1.3.6.1.4.1.498.12.1.3.1.6
Object to option V54 Response RDL to enable or disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

bql613DiagnosticTable 1.3.6.1.4.1.498.12.1.4
The GDC SC613 diagnostics table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Bql613DiagnosticEntry

bql613DiagnosticEntry 1.3.6.1.4.1.498.12.1.4.1
A listing of GDC SC613 diagnostic tests
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Bql613DiagnosticEntry  

bql613DiagnosticIndex 1.3.6.1.4.1.498.12.1.4.1.1
A unique index for the Diagnostic Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

bql613DiagnosticTest 1.3.6.1.4.1.498.12.1.4.1.2
This function selects or reads the test. 0 = no test currently operating 1 = remote loopback test 2 = channel loopback test 4 = data loopback test 8 = selftest 16 = line loopback test 32 = terminate test All other values are test combinations such as 9 = selftest and remote loopback.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..63  

bql613DiagnosticActive 1.3.6.1.4.1.498.12.1.4.1.3
This function represents the test condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notActive(1), active(2)  

bql613DiagnosticResults 1.3.6.1.4.1.498.12.1.4.1.4
This function reads the self test results in bit errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16383  

bql613DiagnosticErrorCount 1.3.6.1.4.1.498.12.1.4.1.5
This function resets the selftest error count for a SC613.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), reset(2)  

bql613Alarm 1.3.6.1.4.1.498.12.7
OBJECT IDENTIFIER    

bql613AlarmData 1.3.6.1.4.1.498.12.7.1
OBJECT IDENTIFIER    

bql613NoResponseAlm 1.3.6.1.4.1.498.12.7.1.1
OBJECT IDENTIFIER    

bql613DiagRxErrAlm 1.3.6.1.4.1.498.12.7.1.2
OBJECT IDENTIFIER    

bql613PowerUpAlm 1.3.6.1.4.1.498.12.7.1.3
OBJECT IDENTIFIER    

bql613Lp2B1QOutofSyncAlm 1.3.6.1.4.1.498.12.7.1.4
OBJECT IDENTIFIER    

bql613LpTxClockOutOfTolerance 1.3.6.1.4.1.498.12.7.1.5
OBJECT IDENTIFIER    

bql613LpExtTxClkAlm 1.3.6.1.4.1.498.12.7.1.6
OBJECT IDENTIFIER    

bql613LpSealingCurrentNoContinuityAlm 1.3.6.1.4.1.498.12.7.1.7
OBJECT IDENTIFIER    

bql613LpMajorBERAlm 1.3.6.1.4.1.498.12.7.1.8
OBJECT IDENTIFIER    

bql613LpMinorBERAlm 1.3.6.1.4.1.498.12.7.1.9
OBJECT IDENTIFIER    

bql613AlarmConfigTable 1.3.6.1.4.1.498.12.7.2
The bql613AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Bql613AlarmConfigEntry

bql613AlarmConfigEntry 1.3.6.1.4.1.498.12.7.2.1
An entry in the bql613AlarmConfigTable table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Bql613AlarmConfigEntry  

bql613AlarmConfigIndex 1.3.6.1.4.1.498.12.7.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

bql613AlarmConfigIdentifier 1.3.6.1.4.1.498.12.7.2.1.2
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

bql613AlarmThreshold 1.3.6.1.4.1.498.12.7.2.1.3
This function sets/reads the Major or Minor BER alarm threshold criteria.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thres10E03(1), thres10E04(2), thres10E05(3), thres10E06(4)  

bql613ControlTable 1.3.6.1.4.1.498.12.1.6
The GDC SC613 Control Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Bql613ControlEntry

bql613ControlEntry 1.3.6.1.4.1.498.12.1.6.1
An entry in the GDC SC613 Control table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Bql613ControlEntry  

bql613ControlIndex 1.3.6.1.4.1.498.12.1.6.1.1
This object is the identifier of the SC613 Control table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

bql613SoftReset 1.3.6.1.4.1.498.12.1.6.1.2
Forces a soft reset on the network element. The reset selection is write only. The normal selection is read only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), reset(2)  

bql613EraseConfig 1.3.6.1.4.1.498.12.1.6.1.3
Forces an erase of the stored configuration in the network element. The erase selection is write only. The normal selection is read only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), erase(2)  

bql613FrontPanel 1.3.6.1.4.1.498.12.1.6.1.4
Object used to enable or disable the units front panel switches.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

bql613LEDStatus 1.3.6.1.4.1.498.12.1.6.1.5
The GDC SC613 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - alarm on 1.4 - loop 1 line loopback 1.3 - loop 1 send data transitions 1.2 - loop 1 receive data transitions 1.1 - loop 1 request to send 1.0 - loop 1 data carrier on 2.7 - not used 2.6 - not used 2.5 - not used 2.4 - loop 2 line loopback 2.3 - loop 2 send data transitions 2.2 - loop 2 receive data transitions 2.1 - loop 2 request to send 2.0 - loop 2 data carrier on 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - loop 3 line loopback 3.3 - loop 3 send data transitions 3.2 - loop 3 receive data transitions 3.1 - loop 3 request to send 3.0 - loop 3 data carrier on
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

bql613CurrentTable 1.3.6.1.4.1.498.12.1.7
The SC613 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Bql613CurrentEntry

bql613CurrentEntry 1.3.6.1.4.1.498.12.1.7.1
An entry in the SC613 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Bql613CurrentEntry  

bql613CurrentIndex 1.3.6.1.4.1.498.12.1.7.1.1
The index value which uniquely identifies the SC613 interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

bql613CurrentStats 1.3.6.1.4.1.498.12.1.7.1.2
The number of Errored Seconds, Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

bql613IntervalTable 1.3.6.1.4.1.498.12.1.8
The SC613 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Bql613IntervalEntry

bql613IntervalEntry 1.3.6.1.4.1.498.12.1.8.1
An entry in the SC613 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Bql613IntervalEntry  

bql613IntervalIndex 1.3.6.1.4.1.498.12.1.8.1.1
The index value which uniquely identifies the ISDN interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

bql613IntervalNumber 1.3.6.1.4.1.498.12.1.8.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minute inter- val (assuming that all 96 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

bql613IntervalStats 1.3.6.1.4.1.498.12.1.8.1.3
The number of Errored Seconds, Severely Errored Seconds and Unavailable Errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

bql613TotalTable 1.3.6.1.4.1.498.12.1.9
The SC613 Total table. 24 hour interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Bql613TotalEntry

bql613TotalEntry 1.3.6.1.4.1.498.12.1.9.1
An entry in the SC613 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Bql613TotalEntry  

bql613TotalIndex 1.3.6.1.4.1.498.12.1.9.1.1
The index value which uniquely identifies the ISDN interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

bql613TotalStats 1.3.6.1.4.1.498.12.1.9.1.2
The number of Errored Seconds,Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

bql613IntervalMaintenanceTable 1.3.6.1.4.1.498.12.1.10
The SC613 Loop Interval Maintenance table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Bql613IntervalMaintenanceEntry

bql613IntervalMaintenanceEntry 1.3.6.1.4.1.498.12.1.10.1
The SC613 Interval Maintenance table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Bql613IntervalMaintenanceEntry  

bql613IntervalMaintenanceIndex 1.3.6.1.4.1.498.12.1.10.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, where is can be 1, 2, or 3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

bql613ResetIntervals 1.3.6.1.4.1.498.12.1.10.1.2
This variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

bql613NumberofValidIntervals 1.3.6.1.4.1.498.12.1.10.1.3
This variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..96  

bql613ResetMajorAlarm 1.3.6.1.4.1.498.12.1.10.1.4
This variable is used to reset alarm per Loop basis.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), norm(2)  

bql613ResetMinorAlarm 1.3.6.1.4.1.498.12.1.10.1.5
This variable is used to reset alarm per Loop basis.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), norm(2)