GDCMP7002-MIB

File: GDCMP7002-MIB.mib (71399 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
GDCMACRO-MIB

Imported symbols

enterprises OBJECT-TYPE DisplayString
SCinstance

Defined Types

Mp7002VersionEntry  
SEQUENCE    
  mp7002VersionIndex SCinstance
  mp7002FirmwareRev DisplayString
  mp7002ModelNumber DisplayString
  mp7002E1x INTEGER

Mp7002MaintenanceEntry  
SEQUENCE    
  mp7002MaintenanceLineIndex SCinstance
  mp7002SoftReset INTEGER
  mp7002SysUpTime INTEGER
  mp7002DefaultInit INTEGER
  mp7002ResetStats INTEGER
  mp7002LedStatus OCTET STRING
  mp7002E1Circuit DisplayString
  mp7002E1XCircuit DisplayString
  mp7002TSBundle1Name DisplayString
  mp7002TSBundle2Name DisplayString
  mp7002SetRealTime INTEGER
  mp7002AlarmStatus OCTET STRING
  mp7002SystemTimingGenStatus INTEGER
  mp7002FarEndResetStats INTEGER
  mp7002NearEndStatLastInitialized INTEGER
  mp7002FarEndStatLastInitialized INTEGER

Mp7002ConfigEntry  
SEQUENCE    
  mp7002ConfigIndex SCinstance
  mp7002InterfaceType INTEGER
  mp7002RcvrRange INTEGER
  mp7002TransmitClockSource INTEGER
  mp7002FallbackClockSource INTEGER
  mp7002FacilityDataLink INTEGER
  mp7002NearEndValidIntervals INTEGER
  mp7002FarEndValidIntervals INTEGER
  mp7002NetworkConnection INTEGER
  mp7002Framing INTEGER
  mp7002LineCoding INTEGER

Mp7002SysTimingEntry  
SEQUENCE    
  mp7002SysTimingIndex SCinstance
  mp7002SysTimingGen INTEGER

Mp7002DCCConfigurationEntry  
SEQUENCE    
  mp7002DCCConfigurationIndex SCinstance
  mp7002TimeSlot INTEGER
  mp7002Bandwidth INTEGER

Mp7002HighwayAssignEntry  
SEQUENCE    
  mp7002HighwayAssignIndex SCinstance
  mp7002TimeSlotBundle INTEGER
  mp7002StartTimeSlot INTEGER
  mp7002NumberOfTimeSlots INTEGER
  mp7002BundleDestination INTEGER
  mp7002ExecuteAssign INTEGER

Mp7002DiagEntry  
SEQUENCE    
  mp7002DiagIndex SCinstance
  mp7002TestPattern INTEGER
  mp7002DiagConfig INTEGER
  mp7002TestLimit INTEGER
  mp7002TestExecutionStatus INTEGER
  mp7002TestExceptions INTEGER
  mp7002TestResults INTEGER
  mp7002ResetTestResults INTEGER

Mp7002NearEndCurrent15MinEntry  
SEQUENCE    
  mp7002NearEndCurrent15MinIndex SCinstance
  mp7002NearEndCurrent15MinStat OCTET STRING

Mp7002NearEndIntervalEntry  
SEQUENCE    
  mp7002NearEndIntervalIndex SCinstance
  mp7002NearEndIntervalNumber INTEGER
  mp7002NearEndIntervalStat OCTET STRING

Mp7002NearEndCurrent24HrEntry  
SEQUENCE    
  mp7002NearEndCurrent24HrIndex SCinstance
  mp7002NearEndCurrent24HrStat OCTET STRING

Mp7002NearEndRecent24HrEntry  
SEQUENCE    
  mp7002NearEndRecent24HrIndex SCinstance
  mp7002NearEndRecent24HrStat OCTET STRING

Mp7002FarEndCurrent15MinEntry  
SEQUENCE    
  mp7002FarEndCurrent15MinIndex SCinstance
  mp7002FarEndCurrent15MinStat OCTET STRING

Mp7002FarEndIntervalEntry  
SEQUENCE    
  mp7002FarEndIntervalIndex SCinstance
  mp7002FarEndIntervalNumber INTEGER
  mp7002FarEndIntervalStat OCTET STRING

Mp7002CurrentFarEnd24HrEntry  
SEQUENCE    
  mp7002CurrentFarEnd24HrIndex SCinstance
  mp7002CurrentFarEnd24HrStat OCTET STRING

Mp7002RecentFarEnd24HrEntry  
SEQUENCE    
  mp7002RecentFarEnd24HrIndex SCinstance
  mp7002RecentFarEnd24HrStat OCTET STRING

Mp7002UnavailableTimeRegEntry  
SEQUENCE    
  mp7002UnavailableTimeRegIndex SCinstance
  mp7002UnavailableTimeRegNumber INTEGER
  mp7002UnavailableTimeRegStart INTEGER
  mp7002UnavailableTimeRegStop INTEGER

Mp7002FarEndUnavailableTimeRegEntry  
SEQUENCE    
  mp7002FarEndUnavailableTimeRegIndex SCinstance
  mp7002FarEndUnavailableTimeRegNumber INTEGER
  mp7002FarEndUnavailableTimeRegStart INTEGER
  mp7002FarEndUnavailableTimeRegStop INTEGER

Mp7002NearEndAlarmConfigEntry  
SEQUENCE    
  mp7002NearEndAlarmConfigIndex SCinstance
  mp7002NearEndAlarmConfigIdentifier OBJECT IDENTIFIER
  mp7002NearEndAlarmCountWindow INTEGER
  mp7002NearEndAlarmCountThreshold INTEGER

Mp7002FarEndAlarmConfigEntry  
SEQUENCE    
  mp7002FarEndAlarmConfigIndex SCinstance
  mp7002FarEndAlarmConfigIdentifier OBJECT IDENTIFIER
  mp7002FarEndAlarmCountWindow INTEGER
  mp7002FarEndAlarmCountThreshold INTEGER

Mp7002LocalAlarmConfigEntry  
SEQUENCE    
  mp7002LocalAlarmConfigIndex SCinstance
  mp7002UASNE INTEGER
  mp7002SESNE INTEGER
  mp7002BBENE INTEGER
  mp7002ESNE INTEGER
  mp7002UASFE INTEGER
  mp7002SESFE INTEGER
  mp7002BBEFE INTEGER
  mp7002ESFE INTEGER
  mp7002LOS INTEGER
  mp7002LOF INTEGER
  mp7002AIS INTEGER
  mp7002TmgLoss INTEGER
  mp7002LCVs INTEGER
  mp7002NtwkRAI INTEGER

Defined Values

gdc 1.3.6.1.4.1.498
OBJECT IDENTIFIER    

dsx1 1.3.6.1.4.1.498.6
OBJECT IDENTIFIER    

mp7002System 1.3.6.1.4.1.498.6.6
OBJECT IDENTIFIER    

mp7002Alarms 1.3.6.1.4.1.498.6.9
OBJECT IDENTIFIER    

mp7002Version 1.3.6.1.4.1.498.6.6.1
OBJECT IDENTIFIER    

mp7002Maintenance 1.3.6.1.4.1.498.6.6.2
OBJECT IDENTIFIER    

mp7002Configuration 1.3.6.1.4.1.498.6.6.3
OBJECT IDENTIFIER    

mp7002Diagnostics 1.3.6.1.4.1.498.6.6.4
OBJECT IDENTIFIER    

mp7002Performance 1.3.6.1.4.1.498.6.6.5
OBJECT IDENTIFIER    

mp7002SysConfig 1.3.6.1.4.1.498.6.6.7
OBJECT IDENTIFIER    

mp7002MIBversion 1.3.6.1.4.1.498.6.6.1.1
Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Acceptable values for the individual revision components are as follows: x: 1 - 9 y: 0 - 9 z: 0 - 9 T: A - Z Upon formal release, no designation for the test revision will be present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(5)  

mp7002VersionTable 1.3.6.1.4.1.498.6.6.1.2
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002VersionEntry

mp7002VersionEntry 1.3.6.1.4.1.498.6.6.1.2.1
An entry in the GDC Mp7002System Version Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002VersionEntry  

mp7002VersionIndex 1.3.6.1.4.1.498.6.6.1.2.1.1
This object identifies Version parameters associated with the managed object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002FirmwareRev 1.3.6.1.4.1.498.6.6.1.2.1.2
The version number of the firmware, to allow products to know which revision is installed. The released version number is sequenced from --, A-, ... AA, ... ZZ. Test versions are numerical from 01 to 99.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(2)  

mp7002ModelNumber 1.3.6.1.4.1.498.6.6.1.2.1.3
This variable is used to determine the type of card family installed ex. MP7002.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

mp7002E1x 1.3.6.1.4.1.498.6.6.1.2.1.4
Indicates if the E1X Cascade Interface is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER installed(1), notPresent(2)  

mp7002MaintenanceTable 1.3.6.1.4.1.498.6.6.2.1
The table describes the maintenance objects for the unit and references the unit interface (cc = 00).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002MaintenanceEntry

mp7002MaintenanceEntry 1.3.6.1.4.1.498.6.6.2.1.1
An entry in the GDC E1 Maintenance Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002MaintenanceEntry  

mp7002MaintenanceLineIndex 1.3.6.1.4.1.498.6.6.2.1.1.1
This object identifies Maintenance parameters associated with the managed object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002SoftReset 1.3.6.1.4.1.498.6.6.2.1.1.2
Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(1) will be returned when the reset is complete. The value of norm(1) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

mp7002SysUpTime 1.3.6.1.4.1.498.6.6.2.1.1.3
This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

mp7002DefaultInit 1.3.6.1.4.1.498.6.6.2.1.1.4
This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(1) the unit will perform a reset to make the default configuration take affect. The value of normal(2) will be returned when the initialization is complete. The value of normal(2) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), factoryDefault(2)  

mp7002ResetStats 1.3.6.1.4.1.498.6.6.2.1.1.5
Supports the action of soft resetting the mp7002NearEndValidIntervals object. When this object is set to reset(2), then the unit will reset the mp7002NearEndValidIntervals object to zero. The value of norm(1) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

mp7002LedStatus 1.3.6.1.4.1.498.6.6.2.1.1.6
Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit 2 - NIU bit 1 - D_I bit 0 - future use Octet 2 bit 7 - not used bit 6 - future use bit 5 - NTWK AIS bit 4 - NTWK LCV bit 3 - NTWK LOS bit 2 - NTWK OOF bit 1 - ALM bit 0 - TM Octet 3 bit 7 - not used bit 6 - ST- future use bit 5 - LT- future use bit 4 - RL- future use bit 3 - future use bit 2 - future use bit 1 - future use bit 0 - future use
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

mp7002E1Circuit 1.3.6.1.4.1.498.6.6.2.1.1.7
Circuit name E1 is connected to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

mp7002E1XCircuit 1.3.6.1.4.1.498.6.6.2.1.1.8
Circuit Name E1X is connected to
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

mp7002TSBundle1Name 1.3.6.1.4.1.498.6.6.2.1.1.9
Name first Time Slot Bundle is assigned to. Only used when unit is configured for drop side interface
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

mp7002TSBundle2Name 1.3.6.1.4.1.498.6.6.2.1.1.10
Name second Time Slot Bundle is assigned to. Only used when unit is configured for drop side interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

mp7002SetRealTime 1.3.6.1.4.1.498.6.6.2.1.1.11
Number of seconds from midnight Dec 31, 1969.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2147483647  

mp7002AlarmStatus 1.3.6.1.4.1.498.6.6.2.1.1.12
Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NWTK_LOS bit 5 - NWTK_LOF bit 4 - NWTK_AIS bit 3 - NTWK_LCV bit 2 - TIMING LOSS bit 1 - NTWK_NE_ES bit 0 - NTWK_NE_BBE Octet 2 bit 7 - not used bit 6 - NTWK_NE_SES bit 5 - NTWK_NE_UAS bit 4 - NTWK_FE_ES bit 3 - NTWK_FE_BBE bit 2 - NTWK_FE_SES bit 1 - NTWK_FE_UAS bit 0 - NTWK_RAI Octet 3 bit 7 - not used bit 6 - E1X_LOS bit 5 - E1X_LOF bit 4 - E1X_AIS bit 3 - E1X_NE_ES bit 2 - E1X_NE_BBE bit 1 - E1X_NE_SES bit 0 - E1X_NE_UAS Octet 4 bit 7 - not used bit 6 - E1X_FE_ES bit 5 - E1X_FE_BBE bit 4 - E1X_FE_SES bit 3 - E1X_FE_UAS bit 2 - NVRAM corrupted bit 1 - unit failure bit 0 - Power-up Alarm
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

mp7002SystemTimingGenStatus 1.3.6.1.4.1.498.6.6.2.1.1.13
Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), clk8khz(2), clk4mhz(3), clk8khzand4mhz(4)  

mp7002FarEndResetStats 1.3.6.1.4.1.498.6.6.2.1.1.14
Supports the action of soft resetting the mp7002FarEndValidIntervals object. When this object is set to reset(2), then the unit will reset the mp7002FarEndValidIntervals object to zero. The value of norm(1) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

mp7002NearEndStatLastInitialized 1.3.6.1.4.1.498.6.6.2.1.1.15
Number of seconds from midnight Dec 31, 1969 up until mp7002NearEndValidIntervals was last initialized to zero
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

mp7002FarEndStatLastInitialized 1.3.6.1.4.1.498.6.6.2.1.1.16
Number of seconds from midnight Dec 31, 1969 up until mp7002FarEndValidIntervals was last initialized to zero
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

mp7002ConfigTable 1.3.6.1.4.1.498.6.6.3.1
The GDC E1 Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002ConfigEntry

mp7002ConfigEntry 1.3.6.1.4.1.498.6.6.3.1.1
The GDC E1 Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002ConfigEntry  

mp7002ConfigIndex 1.3.6.1.4.1.498.6.6.3.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002InterfaceType 1.3.6.1.4.1.498.6.6.3.1.1.2
The operating mode of the interface to be either Network Side, Drop Side or not assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER diu(1), niu(2), notAssigned(3)  

mp7002RcvrRange 1.3.6.1.4.1.498.6.6.3.1.1.3
Sets the receiver range to short (6dB) or long (36dB)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER short(1), long(2)  

mp7002TransmitClockSource 1.3.6.1.4.1.498.6.6.3.1.1.4
Sets the transmit clock source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER system(1), recovered(2), internal(3)  

mp7002FallbackClockSource 1.3.6.1.4.1.498.6.6.3.1.1.5
Identifies the fallback transmit clock source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER system(1), recovered(2), internal(3)  


mp7002NearEndValidIntervals 1.3.6.1.4.1.498.6.6.3.1.1.7
The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. This object is only valid for the E1 interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

mp7002FarEndValidIntervals 1.3.6.1.4.1.498.6.6.3.1.1.8
The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. This object is only valid for the E1 interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

mp7002NetworkConnection 1.3.6.1.4.1.498.6.6.3.1.1.9
Sets whether the network interface is standby or online. This only applies to the Network Interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER onLine(1), standBy(2)  

mp7002Framing 1.3.6.1.4.1.498.6.6.3.1.1.10
Set the framing for the interface. Abbreviations are as follows: CCS - common-channel signaling PCS0 - per channel signaling phase 0 PCS1 - per channel signaling phase 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cCSwithoutCRC4(1), pCS0withoutCRC4(2), pCS1withoutCRC4(3), cCSwithCRC4(4), pCS0withCRC4(5), pCS1withCRC4(6)  

mp7002LineCoding 1.3.6.1.4.1.498.6.6.3.1.1.11
Sets the line coding for the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ami(1), hdb3(2)  

mp7002SysTimingTable 1.3.6.1.4.1.498.6.6.7.1
The GDC System Timing table. These are unit options at the system level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002SysTimingEntry

mp7002SysTimingEntry 1.3.6.1.4.1.498.6.6.7.1.1
The GDC E1 Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002SysTimingEntry  

mp7002SysTimingIndex 1.3.6.1.4.1.498.6.6.7.1.1.1
Index value into the system configuration table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002SysTimingGen 1.3.6.1.4.1.498.6.6.7.1.1.2
Selects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(3) - unit is secondary Timig Generator for the shelf. Only 1 unit in the shelf can the primary or secondary timing generator. All other must be none.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), primary(2), secondary(3)  

mp7002DCCConfigurationTable 1.3.6.1.4.1.498.6.6.3.2
The GDC DCC Configuration table. These are Diagnostic Channel configuration options.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002DCCConfigurationEntry

mp7002DCCConfigurationEntry 1.3.6.1.4.1.498.6.6.3.2.1
The GDC Diagnostic Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002DCCConfigurationEntry  

mp7002DCCConfigurationIndex 1.3.6.1.4.1.498.6.6.3.2.1.1
Index value into the DCC Configuration table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002TimeSlot 1.3.6.1.4.1.498.6.6.3.2.1.2
Time Slot DCC goes in
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

mp7002Bandwidth 1.3.6.1.4.1.498.6.6.3.2.1.3
Bandwidth to use: 8 kbps - bit 7 only 56 kbps - bits 0 - 6 64 kbps - all 8 bits
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER kbps8(1), kbps56(2), kbps64(3), notAssigned(4)  

mp7002HighwayAssignTable 1.3.6.1.4.1.498.6.6.7.2
The GDC System Configuration table. These are unit options at the system level.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002HighwayAssignEntry

mp7002HighwayAssignEntry 1.3.6.1.4.1.498.6.6.7.2.1
The GDC E1 Highway Assign table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002HighwayAssignEntry  

mp7002HighwayAssignIndex 1.3.6.1.4.1.498.6.6.7.2.1.1
Index value into the Highway Assignment table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002TimeSlotBundle 1.3.6.1.4.1.498.6.6.7.2.1.2
Index for the bundle being assigned. A time slot bundle can be assigned to 1 or 2 of the 4 backplane highways. Bundle 1 is asigned in the Aggregate starting at Time Slot 1. Bundle 2 starts at the next available Time Slot. If only one bundle is needed, it must be bundle 1. The execute object should be sent only after acknowlegement of al assignment PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bundle1(1), bundle2(2)  

mp7002StartTimeSlot 1.3.6.1.4.1.498.6.6.7.2.1.3
Starting time slot of the bundle. If only 1 bundle is being assigned, or the first of 2 is being assigned, it must start at 1. The second of 2 must start at the next available time slot after the first bundle.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

mp7002NumberOfTimeSlots 1.3.6.1.4.1.498.6.6.7.2.1.4
Number of time slots assigned to the bundle.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

mp7002BundleDestination 1.3.6.1.4.1.498.6.6.7.2.1.5
Defines the destination of the bundle.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notAssigned(1), highway1(2), highway2(3), highway3(4), highway4(5)  

mp7002ExecuteAssign 1.3.6.1.4.1.498.6.6.7.2.1.6
Causes the MP7002 to execute configuration of the assigned highway configuration. This object should be sent in a separate PDU after acknowlegement of the assign PDU(s) has been recieved.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), execute(2)  

mp7002DiagTable 1.3.6.1.4.1.498.6.6.4.1
The GDC E1 Diagnostics table. Information in the entries of this table support diagnostics testing via loopbacks. Diagnostics are only supported when mp7002InterfaceType is set to niu(2). This table applies to the Network Interface only.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002DiagEntry

mp7002DiagEntry 1.3.6.1.4.1.498.6.6.4.1.1
The GDC E1 Diagnostics table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002DiagEntry  

mp7002DiagIndex 1.3.6.1.4.1.498.6.6.4.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002TestPattern 1.3.6.1.4.1.498.6.6.4.1.1.2
Test pattern for tests that use the pattern generator. The value of this object is used when mp7002DiagConfig.unitTest(5) or mp7002DiagConfig.patGenOn(6) is selected. NOT SUPPORTED BY THE MP7002.
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER noCode(1), pat511(2), pat2047(3), pat1in4(4)  

mp7002DiagConfig 1.3.6.1.4.1.498.6.6.4.1.1.3
Selects the test to run. noLoop(1) ends the test. Interoperates with mp7002TestPattern. When unitTest(2) or patGenOn(3) is selected, the pattern in mp7002TestPattern is used. payloadLoopback(4) and lineLoopback(5) are only valid when the unit is configured for a Network Side interface. localTest(6) is only valid when the unit is configured for a Drop Side interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), lineLoopback(2), payloadLoopback(3), localTest(4), unitTest(5), patGenOn(6)  

mp7002TestLimit 1.3.6.1.4.1.498.6.6.4.1.1.4
Selects the duration to run a diagnostic test. The value(1) noLimit signifies that the test should run indefinitely until explicitly terminated. Default value: testTime10Mins(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER testTime10Mins(1), testTime20Mins(2), noLimit(3)  

mp7002TestExecutionStatus 1.3.6.1.4.1.498.6.6.4.1.1.5
This variable reports the status of a test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a test is currently running. testCompleted(4) indicates that a test has run and is completed. testCompletedNotInTest(5) indicates that a test has completed and it is no longer in test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notInTest(1), testInProgress(2), testCompleted(4), testCompletedNotInTest(5)  

mp7002TestExceptions 1.3.6.1.4.1.498.6.6.4.1.1.6
Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the value zero. Then, for each exception, the value associated with the exception is added to the sum. The exception values are: value exception 1 a timed test was preempted so the result cannot be viewed in relation to the test duration 2 the results overflowed so the result cannot be viewed as an absolute value 4 the test was performed while synchronization could not be performed so the result may not be accurate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

mp7002TestResults 1.3.6.1.4.1.498.6.6.4.1.1.7
The results of the last diagnostic test. This can be the current test running or the last completed test. Note that the interpretation of these results may be affected by the value of the mp7002TestExceptions object. Not supported by MP7002 since no pattern generating tests are supported.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 0..1048576  

mp7002ResetTestResults 1.3.6.1.4.1.498.6.6.4.1.1.8
Resets the diagnostic error count. Not supported by MP7002 since no pattern generating tests are supported.
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

mp7002NearEndCurrent15MinTable 1.3.6.1.4.1.498.6.6.5.1
The mp7002 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002NearEndCurrent15MinEntry

mp7002NearEndCurrent15MinEntry 1.3.6.1.4.1.498.6.6.5.1.1
An entry in the mp7002 NearEnd Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002NearEndCurrent15MinEntry  

mp7002NearEndCurrent15MinIndex 1.3.6.1.4.1.498.6.6.5.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002NearEndCurrent15MinStat 1.3.6.1.4.1.498.6.6.5.1.1.2
Returns a bitwise snapshot of the current 15Min statistics. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

mp7002NearEndIntervalTable 1.3.6.1.4.1.498.6.6.5.2
The mp7002 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002NearEndIntervalEntry

mp7002NearEndIntervalEntry 1.3.6.1.4.1.498.6.6.5.2.1
An entry in the E1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002NearEndIntervalEntry  

mp7002NearEndIntervalIndex 1.3.6.1.4.1.498.6.6.5.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002NearEndIntervalNumber 1.3.6.1.4.1.498.6.6.5.2.1.2
The number of Errored Seconds encountered by an E1 interface in one of the previous 16, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

mp7002NearEndIntervalStat 1.3.6.1.4.1.498.6.6.5.2.1.3
Returns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

mp7002NearEndCurrent24HrTable 1.3.6.1.4.1.498.6.6.5.3
The E1 Current24Hr table. 4 hour interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002NearEndCurrent24HrEntry

mp7002NearEndCurrent24HrEntry 1.3.6.1.4.1.498.6.6.5.3.1
An entry in the E1 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002NearEndCurrent24HrEntry  

mp7002NearEndCurrent24HrIndex 1.3.6.1.4.1.498.6.6.5.3.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002NearEndCurrent24HrStat 1.3.6.1.4.1.498.6.6.5.3.1.2
Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

mp7002NearEndRecent24HrTable 1.3.6.1.4.1.498.6.6.5.4
The E1 Recent24Hr table. 4 hour interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002NearEndRecent24HrEntry

mp7002NearEndRecent24HrEntry 1.3.6.1.4.1.498.6.6.5.4.1
An entry in the E1 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002NearEndRecent24HrEntry  

mp7002NearEndRecent24HrIndex 1.3.6.1.4.1.498.6.6.5.4.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002NearEndRecent24HrStat 1.3.6.1.4.1.498.6.6.5.4.1.2
Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

mp7002FarEndCurrent15MinTable 1.3.6.1.4.1.498.6.6.5.5
The mp7002FarEnd Current 15 minute table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002FarEndCurrent15MinEntry

mp7002FarEndCurrent15MinEntry 1.3.6.1.4.1.498.6.6.5.5.1
An entry in the mp7002FarEnd Current 15 Minute table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002FarEndCurrent15MinEntry  

mp7002FarEndCurrent15MinIndex 1.3.6.1.4.1.498.6.6.5.5.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002FarEndCurrent15MinStat 1.3.6.1.4.1.498.6.6.5.5.1.2
Returns a bitwise map of the far end interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(9)  

mp7002FarEndIntervalTable 1.3.6.1.4.1.498.6.6.5.6
The mp7002FarEnd Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002FarEndIntervalEntry

mp7002FarEndIntervalEntry 1.3.6.1.4.1.498.6.6.5.6.1
An entry in the Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002FarEndIntervalEntry  

mp7002FarEndIntervalIndex 1.3.6.1.4.1.498.6.6.5.6.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002FarEndIntervalNumber 1.3.6.1.4.1.498.6.6.5.6.1.2
A number between 1 and 16, where 1 is the most recently completed 15 minute interval and 16 is the least recently completed 15 minutes interval (assuming that all 16 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

mp7002FarEndIntervalStat 1.3.6.1.4.1.498.6.6.5.6.1.3
Returns a bitwise map of statistics for the far end interface in the current 15 minute interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(9)  

mp7002CurrentFarEnd24HrTable 1.3.6.1.4.1.498.6.6.5.7
The Current 24 Hour table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002CurrentFarEnd24HrEntry

mp7002CurrentFarEnd24HrEntry 1.3.6.1.4.1.498.6.6.5.7.1
An entry in the Current 24 Hr table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002CurrentFarEnd24HrEntry  

mp7002CurrentFarEnd24HrIndex 1.3.6.1.4.1.498.6.6.5.7.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002CurrentFarEnd24HrStat 1.3.6.1.4.1.498.6.6.5.7.1.2
Returns a bitwise map of statistics for the interface in the current 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

mp7002RecentFarEnd24HrTable 1.3.6.1.4.1.498.6.6.5.8
The Recent 24 Hour table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002RecentFarEnd24HrEntry

mp7002RecentFarEnd24HrEntry 1.3.6.1.4.1.498.6.6.5.8.1
An entry in the Recent 24 Hr table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002RecentFarEnd24HrEntry  

mp7002RecentFarEnd24HrIndex 1.3.6.1.4.1.498.6.6.5.8.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002RecentFarEnd24HrStat 1.3.6.1.4.1.498.6.6.5.8.1.2
Returns a bitwise map of statistics for the interface in the Recent 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

mp7002UnavailableTimeRegTable 1.3.6.1.4.1.498.6.6.5.9
The mp7002 Near End Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002UnavailableTimeRegEntry

mp7002UnavailableTimeRegEntry 1.3.6.1.4.1.498.6.6.5.9.1
An entry in the Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002UnavailableTimeRegEntry  

mp7002UnavailableTimeRegIndex 1.3.6.1.4.1.498.6.6.5.9.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002UnavailableTimeRegNumber 1.3.6.1.4.1.498.6.6.5.9.1.2
A number between 1 and 6, where the number is the number of the Unavailable Time Register.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

mp7002UnavailableTimeRegStart 1.3.6.1.4.1.498.6.6.5.9.1.3
Start time of one of the Unavailable Time Registers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

mp7002UnavailableTimeRegStop 1.3.6.1.4.1.498.6.6.5.9.1.4
Stop time of one of the Unavailable Time Registers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

mp7002FarEndUnavailableTimeRegTable 1.3.6.1.4.1.498.6.6.5.10
The mp7002 Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002FarEndUnavailableTimeRegEntry

mp7002FarEndUnavailableTimeRegEntry 1.3.6.1.4.1.498.6.6.5.10.1
An entry in the Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002FarEndUnavailableTimeRegEntry  

mp7002FarEndUnavailableTimeRegIndex 1.3.6.1.4.1.498.6.6.5.10.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002FarEndUnavailableTimeRegNumber 1.3.6.1.4.1.498.6.6.5.10.1.2
A number between 1 and 6, where the number is the number of the Unavailable Time Register.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

mp7002FarEndUnavailableTimeRegStart 1.3.6.1.4.1.498.6.6.5.10.1.3
Start time of one of the Unavailable Time Registers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

mp7002FarEndUnavailableTimeRegStop 1.3.6.1.4.1.498.6.6.5.10.1.4
Stop time of one of the Unavailable Time Registers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

mp7002AlarmData 1.3.6.1.4.1.498.6.9.1
OBJECT IDENTIFIER    

mp7002NoResponseAlm 1.3.6.1.4.1.498.6.9.1.1
OBJECT IDENTIFIER    

mp7002DiagRxErrAlm 1.3.6.1.4.1.498.6.9.1.2
OBJECT IDENTIFIER    

mp7002PowerUpAlm 1.3.6.1.4.1.498.6.9.1.3
OBJECT IDENTIFIER    

mp7002NvRamCorrupt 1.3.6.1.4.1.498.6.9.1.4
OBJECT IDENTIFIER    

mp7002UnitFailure 1.3.6.1.4.1.498.6.9.1.5
OBJECT IDENTIFIER    

mp7002TimingLoss 1.3.6.1.4.1.498.6.9.1.6
OBJECT IDENTIFIER    

mp7002LCV 1.3.6.1.4.1.498.6.9.1.7
OBJECT IDENTIFIER    

mp7002LossOfSignal 1.3.6.1.4.1.498.6.9.1.8
OBJECT IDENTIFIER    

mp7002LossOfFrame 1.3.6.1.4.1.498.6.9.1.9
OBJECT IDENTIFIER    

mp7002AlarmIndSignal 1.3.6.1.4.1.498.6.9.1.10
OBJECT IDENTIFIER    

mp7002NEES 1.3.6.1.4.1.498.6.9.1.11
OBJECT IDENTIFIER    

mp7002NEBBE 1.3.6.1.4.1.498.6.9.1.12
OBJECT IDENTIFIER    

mp7002NESES 1.3.6.1.4.1.498.6.9.1.13
OBJECT IDENTIFIER    

mp7002NEUAS 1.3.6.1.4.1.498.6.9.1.14
OBJECT IDENTIFIER    

mp7002FEES 1.3.6.1.4.1.498.6.9.1.15
OBJECT IDENTIFIER    

mp7002FEBBE 1.3.6.1.4.1.498.6.9.1.16
OBJECT IDENTIFIER    

mp7002FESES 1.3.6.1.4.1.498.6.9.1.17
OBJECT IDENTIFIER    

mp7002FEUAS 1.3.6.1.4.1.498.6.9.1.18
OBJECT IDENTIFIER    

mp7002RAI 1.3.6.1.4.1.498.6.9.1.19
OBJECT IDENTIFIER    

mp7002NearEndAlarmConfigTable 1.3.6.1.4.1.498.6.9.2
The mp7002NearEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002NearEndAlarmConfigEntry

mp7002NearEndAlarmConfigEntry 1.3.6.1.4.1.498.6.9.2.1
An entry in the MP7002 Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002NearEndAlarmConfigEntry  

mp7002NearEndAlarmConfigIndex 1.3.6.1.4.1.498.6.9.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002NearEndAlarmConfigIdentifier 1.3.6.1.4.1.498.6.9.2.1.2
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

mp7002NearEndAlarmCountWindow 1.3.6.1.4.1.498.6.9.2.1.3
This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Default: disabled(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), last1sec(2), last10sec(3), last30sec(4), last1min(5), last15min(6), last1hr(7), last24hr(8), infinite(9)  

mp7002NearEndAlarmCountThreshold 1.3.6.1.4.1.498.6.9.2.1.4
This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Default: thresGT1(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thresGT1(1), thresGT3(2), thresGT10(3), thresGT100(4), thresGT1000(5), thresGT10000(6)  

mp7002FarEndAlarmConfigTable 1.3.6.1.4.1.498.6.9.3
The mp7002FarEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002FarEndAlarmConfigEntry

mp7002FarEndAlarmConfigEntry 1.3.6.1.4.1.498.6.9.3.1
An entry in the MP7002 Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002FarEndAlarmConfigEntry  

mp7002FarEndAlarmConfigIndex 1.3.6.1.4.1.498.6.9.3.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002FarEndAlarmConfigIdentifier 1.3.6.1.4.1.498.6.9.3.1.2
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

mp7002FarEndAlarmCountWindow 1.3.6.1.4.1.498.6.9.3.1.3
This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Default: disabled(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), last1sec(2), last10sec(3), last30sec(4), last1min(5), last15min(6), last1hr(7), last24hr(8), infinite(9)  

mp7002FarEndAlarmCountThreshold 1.3.6.1.4.1.498.6.9.3.1.4
This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Default: thresGT1(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thresGT1(1), thresGT3(2), thresGT10(3), thresGT100(4), thresGT1000(5), thresGT10000(6)  

mp7002LocalAlarmConfigTable 1.3.6.1.4.1.498.6.9.4
The mp7002LocalAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mp7002LocalAlarmConfigEntry

mp7002LocalAlarmConfigEntry 1.3.6.1.4.1.498.6.9.4.1
An entry in the GDC Local Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mp7002LocalAlarmConfigEntry  

mp7002LocalAlarmConfigIndex 1.3.6.1.4.1.498.6.9.4.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

mp7002UASNE 1.3.6.1.4.1.498.6.9.4.1.2
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002SESNE 1.3.6.1.4.1.498.6.9.4.1.3
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002BBENE 1.3.6.1.4.1.498.6.9.4.1.4
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002ESNE 1.3.6.1.4.1.498.6.9.4.1.5
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002UASFE 1.3.6.1.4.1.498.6.9.4.1.6
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002SESFE 1.3.6.1.4.1.498.6.9.4.1.7
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002BBEFE 1.3.6.1.4.1.498.6.9.4.1.8
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002ESFE 1.3.6.1.4.1.498.6.9.4.1.9
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002LOS 1.3.6.1.4.1.498.6.9.4.1.10
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002LOF 1.3.6.1.4.1.498.6.9.4.1.11
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002AIS 1.3.6.1.4.1.498.6.9.4.1.12
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002TmgLoss 1.3.6.1.4.1.498.6.9.4.1.13
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002LCVs 1.3.6.1.4.1.498.6.9.4.1.14
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

mp7002NtwkRAI 1.3.6.1.4.1.498.6.9.4.1.15
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)