GDCDSX1-MIB

File: GDCDSX1-MIB.mib (79138 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
GDCMACRO-MIB

Imported symbols

Gauge enterprises TimeTicks
OBJECT-TYPE DisplayString SCinstance

Defined Types

GdcDsx1VersionEntry  
SEQUENCE    
  gdcDsx1VersionIndex SCinstance
  gdcDsx1FirmwareRev DisplayString
  gdcDsx1ModelNumber DisplayString
  gdcDsx1ActiveFirmwareRev DisplayString
  gdcDsx1StoredFirmwareRev DisplayString
  gdcDsx1BootRev DisplayString
  gdcDsx1StoredFirmwareStatus INTEGER
  gdcDsx1SwitchActiveFirmware INTEGER
  gdcDsx1DownloadingMode INTEGER

GdcDsx1MaintenanceEntry  
SEQUENCE    
  gdcDsx1MaintenanceLineIndex SCinstance
  gdcDsx1SoftReset INTEGER
  gdcDsx1ConfigMode INTEGER
  gdcDsx1FrontPanel INTEGER
  gdcDsx1SysUpTime TimeTicks
  gdcDsx1DefaultInit INTEGER
  gdcDsx1ResetStats INTEGER
  gdcDsx1LedStatus OCTET STRING
  gdcDsx1SetTransmitClkSrc INTEGER
  gdcDsx1CsuMode INTEGER
  gdcDsx1CircuitIdentifier1 DisplayString
  gdcDsx1CircuitIdentifier2 DisplayString

GdcDsx1NetMaintEntry  
SEQUENCE    
  gdcDsx1NetMaintLineIndex SCinstance
  gdcDsx1NetMaintReceiveLevel INTEGER
  gdcDsx1NetMaintAttenSense INTEGER

GdcDsx1ConfigEntry  
SEQUENCE    
  gdcDsx1ConfigIndex SCinstance
  gdcDsx1LineType INTEGER
  gdcDsx1InterfaceType INTEGER
  gdcDsx1Preequalization INTEGER
  gdcDsx1AdminLineBuildout INTEGER
  gdcDsx1OperLineBuildout INTEGER
  gdcDsx1AdminRcvRange INTEGER
  gdcDsx1OperRcvRange INTEGER
  gdcDsx1OnesDensity INTEGER
  gdcDsx1TransmitClockSource INTEGER
  gdcDsx1FallbackClockSource INTEGER
  gdcDsx1AISLoopdown INTEGER
  gdcDsx1InbandLoopCfg INTEGER
  gdcDsx1Redundancy INTEGER

GdcDsx1DiagEntry  
SEQUENCE    
  gdcDsx1DiagIndex SCinstance
  gdcDsx1SendCode INTEGER
  gdcDsx1LoopbackConfig INTEGER
  gdcDsx1DS0Diag INTEGER
  gdcDsx1TestDuration INTEGER
  gdcDsx1TestExecutionStatus INTEGER
  gdcDsx1TestExceptions INTEGER
  gdcDsx1TestResults INTEGER

GdcDsx1ANSIperfEntry  
SEQUENCE    
  gdcDsx1ANSIperfIndex SCinstance
  gdcDsx1ANSIdirection INTEGER
  gdcDsx1ANSIseconds INTEGER
  gdcDsx1ANSICRCerrorEvents INTEGER
  gdcDsx1ANSIsevereErrors INTEGER
  gdcDsx1ANSIframeErrors INTEGER
  gdcDsx1ANSIcodeViolations INTEGER
  gdcDsx1ANSIcontrolledSlips INTEGER
  gdcDsx1ANSIactivePayloadLoops INTEGER

GdcDsx1CurrentEntry  
SEQUENCE    
  gdcDsx1CurrentIndex SCinstance
  gdcDsx1CurrentLOFCs Gauge
  gdcDsx1CurrenUserStat OCTET STRING

GdcDsx1IntervalEntry  
SEQUENCE    
  gdcDsx1IntervalIndex SCinstance
  gdcDsx1IntervalNumber INTEGER
  gdcDsx1IntervalLOFCs Gauge

GdcDsx1TotalEntry  
SEQUENCE    
  gdcDsx1TotalIndex SCinstance
  gdcDsx1TotalLOFCs Gauge

GdcDsx1AlarmConfigEntry  
SEQUENCE    
  gdcDsx1AlarmConfigIndex SCinstance
  gdcDsx1AlarmConfigIdentifier OBJECT IDENTIFIER
  gdcDsx1AlarmCountWindow INTEGER
  gdcDsx1AlarmCountThreshold INTEGER

GdcDsx1AlarmStatusEntry  
SEQUENCE    
  gdcDsx1AlarmStatusIndex SCinstance
  gdcDsx1AlarmStatusIdentifier OBJECT IDENTIFIER
  gdcDsx1AlarmCount Gauge
  gdcDsx1AlarmFirstOccurrence TimeTicks
  gdcDsx1AlarmLastOccurrence TimeTicks

Defined Values

gdc 1.3.6.1.4.1.498
OBJECT IDENTIFIER    

dsx1 1.3.6.1.4.1.498.6
OBJECT IDENTIFIER    

gdcDsx1System 1.3.6.1.4.1.498.6.1
OBJECT IDENTIFIER    

sc5001 1.3.6.1.4.1.498.6.2
OBJECT IDENTIFIER    

gdcDsx1Version 1.3.6.1.4.1.498.6.1.1
OBJECT IDENTIFIER    

gdcDsx1Maintenance 1.3.6.1.4.1.498.6.1.2
OBJECT IDENTIFIER    

gdcDsx1Configuration 1.3.6.1.4.1.498.6.1.3
OBJECT IDENTIFIER    

gdcDsx1Diagnostics 1.3.6.1.4.1.498.6.1.4
OBJECT IDENTIFIER    

gdcDsx1Performance 1.3.6.1.4.1.498.6.1.5
OBJECT IDENTIFIER    

gdcDsx1Alarms 1.3.6.1.4.1.498.6.1.6
OBJECT IDENTIFIER    

gdcDsx1NetMaintenance 1.3.6.1.4.1.498.6.1.7
OBJECT IDENTIFIER    

gdcDsx1SystemMIBversion 1.3.6.1.4.1.498.6.1.1.1
Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Acceptable values for the individual revision components are as follows: x: 1 - 9 y: 0 - 9 z: 0 - 9 T: A - Z Upon formal release, no designation for the test revision will be present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(5)  

gdcDsx1VersionTable 1.3.6.1.4.1.498.6.1.1.2
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1VersionEntry

gdcDsx1VersionEntry 1.3.6.1.4.1.498.6.1.1.2.1
An entry in the GDC gdcDsx1 Version Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1VersionEntry  

gdcDsx1VersionIndex 1.3.6.1.4.1.498.6.1.1.2.1.1
Identifies Version parameters associated with the managed object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1FirmwareRev 1.3.6.1.4.1.498.6.1.1.2.1.2
The version number of the bootstrap firmware. The version number of the firmware, to allow products to know which revision is installed. The released version number is sequenced from --, A-, ... AA, ... ZZ.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(2)  

gdcDsx1ModelNumber 1.3.6.1.4.1.498.6.1.1.2.1.3
This variable is used to determine the type of card family installed ex. SC5001, SC5002.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

gdcDsx1ActiveFirmwareRev 1.3.6.1.4.1.498.6.1.1.2.1.4
The version number of the firmware currently executing. The format is MM.NN.BB where: MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

gdcDsx1StoredFirmwareRev 1.3.6.1.4.1.498.6.1.1.2.1.5
The version number of the firmware stored (in a compressed format) but not currently executing. MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

gdcDsx1BootRev 1.3.6.1.4.1.498.6.1.1.2.1.6
The version number of the bootstrap firmware. The version number of the firmware, to allow products to know which revision is installed. The released version number is sequenced from --, A-, ... AA, ... ZZ.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(2)  

gdcDsx1StoredFirmwareStatus 1.3.6.1.4.1.498.6.1.1.2.1.7
This object represents the state of the Non-Active or Stored firmware: statBlank(1) Factory Default statDownLoading(2) In process of downloading firmware statOK(3) Zipped version checksum succesful (OK to switch) (can set gdcDsx1SwitchActive to switchActive(2)) statCheckSumBad(4) Failed checksum after download statUnZipping(5) In process of uncompressing into active area statBadUnZip(6) Failed last uncompress The object is read only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER statBlank(1), statDownLoading(2), statOK(3), statCheckSumBad(4), statUnZipping(5), statBadUnZip(6)  

gdcDsx1SwitchActiveFirmware 1.3.6.1.4.1.498.6.1.1.2.1.8
This object is used to switch the active executing firmware from the version in gdcDsx1ActiveRev to the version in gdcDsx1StoredRev. When a switchActive(2) is set (write only) the element will: 1) reboot 2) uncompress stored code into active area 3) perform checksum on active area 4) Set gdcDsx1StoredStatus object to indicate results 5) If succesfull: update gdcDsx1ActiveFirmwareRev and gdcDsx1StoredFirmwareRev and begin executing If failed: replace active area with previous revision The switchNorm(1) enumeration will always be read. Setting switchActive(2) when the gdcDsx1StoredStatus is not statOK(3) will result in an error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switchNorm(1), switchActive(2)  

gdcDsx1DownloadingMode 1.3.6.1.4.1.498.6.1.1.2.1.9
This object is used to configure the download mode: disableAll(1) Prevents any firmware downloading to gdcDsx1 enableAndWait(2) Allows downloading zipped code to be stored only! enableAndSwitch(3) Allows downloading and then unzips and begins executing the new code
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disableAll(1), enableAndWait(2), enableAndSwitch(3)  

gdcDsx1MaintenanceTable 1.3.6.1.4.1.498.6.1.2.1
The table describes the maintenance objects for the unit and references the unit interface (cc = 00).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1MaintenanceEntry

gdcDsx1MaintenanceEntry 1.3.6.1.4.1.498.6.1.2.1.1
An entry in the GDC ltu Maintenance Configuration Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1MaintenanceEntry  

gdcDsx1MaintenanceLineIndex 1.3.6.1.4.1.498.6.1.2.1.1.1
This object identifies Maintenance parameters associated with the managed object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1SoftReset 1.3.6.1.4.1.498.6.1.2.1.1.2
Supports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(2) will be returned when the reset is complete. The value of norm(2) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), norm(2)  

gdcDsx1ConfigMode 1.3.6.1.4.1.498.6.1.2.1.1.4
The hardware configuration mode of the unit. A unit may be configured through hardware switches, jumper, straps, etc. The value software(2) indicates that the unit is software configurable. The value of hardware(1) indicates that some options are hard configured and that software configuration is not permitted of these options. The value of hardware(1) can not be set by management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hardware(1), software(2)  

gdcDsx1FrontPanel 1.3.6.1.4.1.498.6.1.2.1.1.5
This variable is used to indicate whether the front panel switches are operational or not. 'inhibit' refers to when the front panel switches are not operational. 'enable' refers to when the front panel switches are operational.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inhibit(1), enable(2)  

gdcDsx1SysUpTime 1.3.6.1.4.1.498.6.1.2.1.1.6
This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

gdcDsx1DefaultInit 1.3.6.1.4.1.498.6.1.2.1.1.7
This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(1) the unit will perform a reset to make the default configuration take affect. The value of normal(2) will be returned when the initialization is complete. The value of normal(2) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER factoryDefault(1), normal(2)  

gdcDsx1ResetStats 1.3.6.1.4.1.498.6.1.2.1.1.8
Supports the action of soft resetting the dsx1ValidIntervals object. When this object is set to reset(9), then the unit will reset the dsx1ValidIntervals object to zero. The value of norm(1) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(9)  

gdcDsx1LedStatus 1.3.6.1.4.1.498.6.1.2.1.1.9
Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit 2 - EQ LAD bit 1 - EQ 0'S bit 0 - EQ NS Octet 2 bit 7 - not used bit 6 - EQ OOF bit 5 - NTWK AIS bit 4 - NTWK BPV bit 3 - NTWK NS bit 2 - NTWK OOF bit 1 - ALM bit 0 - TM Octet 3 bit 7 - not used bit 6 - ST bit 5 - LT bit 4 - RL bit 3 - future use bit 2 - future use bit 1 - future use bit 0 - future use
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

gdcDsx1SetTransmitClkSrc 1.3.6.1.4.1.498.6.1.2.1.1.10
'txClkSrc' indicates the unit is using the optioned clock source as indicated by the dsx1TransmitClockSource variable in the RFC1406 mib or the gdcDsx1TransmitClockSource variable in the gdcdsx1 mib. 'fallBackClkSrc' indicates the unit is using the optioned clock source as indicated by the gdcDsx1FallbackClockSource variable in the gdcdsx1 mib.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER txClkSrc(1), fallBackClkSrc(2)  

gdcDsx1CsuMode 1.3.6.1.4.1.498.6.1.2.1.1.11
'csuMode' indicates the unit is operating as a T1 channel service unit with the payload from the network interface connected to the payload of the cascade interface. 'concentratorMode' indicates the unit is operating as a T1 channel service unit with the T1 payloads groomed to cross connect within the shelf and the network and cascade interfaces.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER csuMode(1), concentratorMode(2)  

gdcDsx1CircuitIdentifier1 1.3.6.1.4.1.498.6.1.2.1.1.12
Private data storage area of sixteen bytes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

gdcDsx1CircuitIdentifier2 1.3.6.1.4.1.498.6.1.2.1.1.13
Private data storage area of sixteen bytes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

gdcDsx1NetMaintTable 1.3.6.1.4.1.498.6.1.7.1
The table describes the maintenance objects for the network and references the network interface (cc = 01).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1NetMaintEntry

gdcDsx1NetMaintEntry 1.3.6.1.4.1.498.6.1.7.1.1
An entry in the GDC ltu Network Maintenance Configuration Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1NetMaintEntry  

gdcDsx1NetMaintLineIndex 1.3.6.1.4.1.498.6.1.7.1.1.1
This object identifies Maintenance parameters associated with the managed object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1NetMaintReceiveLevel 1.3.6.1.4.1.498.6.1.7.1.1.2
This variable reports the absolute value of the network relative receive level of -40dB to +3dB when the gdcDsx1InterfaceType is set for ds1(1). This object interacts with the gdcDsx1NetMaintAttenSense object in determining the unit's actual Receive Level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..43  

gdcDsx1NetMaintAttenSense 1.3.6.1.4.1.498.6.1.7.1.1.3
This variable identifies ths sense of the gdcdsx1NetReceiveLevel variable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER positive(1), negative(2)  

gdcDsx1ConfigTable 1.3.6.1.4.1.498.6.1.3.1
The GDC DS1 Configuration table. Information in the entries of this table augment the entries in the DS1 Configuration table of the DS1 MIB defined in RFC 1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1ConfigEntry

gdcDsx1ConfigEntry 1.3.6.1.4.1.498.6.1.3.1.1
The GDC DS1 Configuration table entry. The information in this entry augments the information for the corresponding entry in the dsx1ConfigEntry of the DS1 MIB defined in RFC 1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1ConfigEntry  

gdcDsx1ConfigIndex 1.3.6.1.4.1.498.6.1.3.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and sub-identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1LineType 1.3.6.1.4.1.498.6.1.3.1.1.2
This variable indicates the variety of DS-X Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: 'auto' indicates the unit is still determining framing when gdcDsx1LineType is set for auto (1) dsx1LineType reads other(1). 'manEsf' indicates manual selection of extended superframe format 'manD4'indicates manual selection of D4 framing format 'unframed' indicates manual selection of unframed format Reference rfc1406 dsx1LineType gdcDsx1LineType dsx1ESF (2) ============> manESF (2) dsx1D4 (3) ============> manD4 (3) All other values in dsx1LineType are not supported at this time. Default value: manESF (2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manEsf(2), manD4(3), unframed(4)  

gdcDsx1InterfaceType 1.3.6.1.4.1.498.6.1.3.1.1.3
The operating mode of the interface. Setting the value of this object to ds1(2) configures the interface as standard DS1. Setting the value of this object to dsx1(3) configures the interface to operate as a standard cross-connect DSX-1. The value other(1) identifies another interface mode defined elsewhere. This value can never be set by management operation. This object interoperates with the gdcDsx1Preequalization object. When this object is set to ds1(2), then the value of gdcDsx1Preequalization does not apply. This object interoperates with the gdcDsx1AdminLineBuildout object. When this object is set to dsx1(3), then the value of gdcDsx1LineBuildout does not apply. This object interoperates with the gdcDsx1AdminLineBuildout object. When this object is set to dsx1(3), then the value of gdcDsx1AutoLineBuildout does not apply. This object interoperates with the gdcDsx1AdminReceiveRange object. When this object is set to dsx1(3), then the value of gdcDsx1ReceiveRange does not apply. This object interoperates with the gdcDsx1AdminReceiveRange object. When this object is set to dsx1(3), then the value of gdcDsx1AutoReceiveRange is set to disabled(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), ds1(2), dsx1(3)  

gdcDsx1Preequalization 1.3.6.1.4.1.498.6.1.3.1.1.4
Is the preequalization of the transmitter of the interface. The value other(1) identifies an other preequalization value which is defined elsewhere. This value can never be set by management operation. This object interoperates with the object gdcDsx1InterfaceType. When the value of gdcDsx1InterfaceType is ds1(2) then this value is not applicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), preeq130(2), preeq260(3), preeq390(4), preeq530(5), preeq655(6), none(7)  

gdcDsx1AdminLineBuildout 1.3.6.1.4.1.498.6.1.3.1.1.5
This variable is used to set the Transmit Ntwk Build-Out value on the network side and is only valid if the gdcDsx1InterfaceType is set for ds1(1). The values, in sequence, describe: 'auto' indicates auto detection of receive level to determine the appropriate Ntwk build out without controller intervention 'man00dB' indicates manual selection of 0.0 dB transmit Ntwk build out 'man75dB' indicates manual selection of -7.5 dB transmit Ntwk build out 'man150dB' indicates manual selection of -15.0 dB transmit Ntwk build out Set/get of auto requires a reading of gdcDsx1OperLineBuildOut to determine the selection of the Ntwk buildout. Caution must be used when setting auto since only one unit on a link can be in auto at a given time. Default value: man00dB (2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), man00dB(2), man75dB(3), man150dB(4)  

gdcDsx1OperLineBuildout 1.3.6.1.4.1.498.6.1.3.1.1.6
This variable is used to report the current Ntwk build-out setting if the gdcDsx1InterfaceType is set for ds1(1). 'inProcess' indicates the unit is still determining the Ntwk build out required when the gdcDsx1AdminLineBuildout is set for auto (1) 'tx00dB' indicates the unit is set for 0.0 dB of attenuation when the gdcDsx1AdminLineBuildout is set for auto (1) or man00dB (2) 'tx75dB' indicates the unit is set for -7.5 dB of attenuation when the gdcDsx1AdminLineBuildout is set for auto (1) or man75dB (3) 'tx150dB' indicates the unit is set for -15.0 dB of attenuation when the gdcDsx1AdminLineBuildout is set for auto (1) or man150dB (4)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inProcess(1), tx00dB(2), tx75dB(3), tx150dB(4)  

gdcDsx1AdminRcvRange 1.3.6.1.4.1.498.6.1.3.1.1.7
This variable is used to set the receiver circuitry for signal recovery ranges when gdcDsx1InterfaceType is set for ds1 (1). This function is not supported for gdcDsx1InterfaceType set for dsx1 (2). Normal range is considered 0 to -28 dB and extended range is from -20 to -40 dB relative to a DS-1 launch pulse. The values,in sequence, describe: 'auto' indicates auto selection of receiver range 'manNorm' indicates manual selection of normal range 'manExt' indicates manual selection of extended range Set/get of auto requires a reading of gdcDsx1OperRcvRange to determine the selection of the receiver range. Caution must be used when setting auto since only one unit on a link can be in auto at a given time. Default value: auto(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manNorm(2), manExt(3)  

gdcDsx1OperRcvRange 1.3.6.1.4.1.498.6.1.3.1.1.8
This variable is used to report the current receiver range setting when gdcDsx1InterfaceType is set for ds1 (1). 'inProcess' indicates the unit is still determining the required receiver range when the gdcDsx1AdminRcvRange is set for auto (1) 'norm' indicates the receiver is set for normal range when the gdcDsx1AdminRcvRange is set for auto (1) or manNorm (2) 'ext' indicates the receiver is set for extended range when the gdcDsx1AdminRcvRange is set for auto (1) or manExt (3)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inProcess(1), norm(2), ext(3)  

gdcDsx1OnesDensity 1.3.6.1.4.1.498.6.1.3.1.1.9
The ones density restriction for the interface. The values of this object define the ones density restriction that is enforced on the interface. The value inhibit(1) indicates that no ones density restriction is enforced. The value max15zeros(2) indicates that a maximum of 15 zeros are transmitted to the network before a one is inserted. The value max39zeros(3) indicates that a maximum of 39 zeros are transmitted to the network before a one is inserted. The value restrict8nX1(4) indicates a minimum of N ones per 8(N+1) bits, where N is in the range 1 to 24. The value min1in8(5) indicates a minimum of 1 one per 8 bits. With this value, pulse density violations are enforced but not recorded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inhibit(1), max15zeros(2), max39zeros(3), restrict8XNplus1(4), min1in8(5)  

gdcDsx1TransmitClockSource 1.3.6.1.4.1.498.6.1.3.1.1.10
Augments the dsx1TransmitClockSource of the DS1 MIB of RFC 1406. This object defines transmit clock sources that are not defined by RFC 1406, but are supported by GDC DS1 interfaces. The value other(1) indicates that the DS1 transmit clock source is defined elsewhere. The other values identify other timing sources as indicated. The value other(1) can never be set by management operation. This object interoperates with the dsx1TransmitClockSource object. When the dsx1TransmitClockSource is set to loopTiming(1) or localTiming(2), the value of this object reflects other(1). When the value of this object has a value other than other(1), then the value of the dsx1TransmitClockSource object reflects throughTiming(3). The value channel(4) interoperates with the gdcDsuChannelTransmitClockSource object. When this value is selected, gdcDsuChannelTransmitClockSource is set to the appropriate channel of the clock source for multi-channel products.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), station(2), cascade(3), channel(4), composite(5), shelf(6)  

gdcDsx1FallbackClockSource 1.3.6.1.4.1.498.6.1.3.1.1.11
Identifies the fallback transmit clock source. The value of other(1) identifies another fallback transmit clock source that is defined elsewhere. The value of none(2) indicates no fallback transmit clock source. The value other(1) can never be set by management operation. The value channel(4) interoperates with the gdcDsuChannelTransmitClockSource object. When this value is selected, gdcDsuChannelTransmitClockSource is set to the appropriate channel of the clock source for multi-channel products.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), none(2), composite(3), loopTiming(4), channel(5), cascade(6), localTiming(7), station(8), shelf(9)  

gdcDsx1AISLoopdown 1.3.6.1.4.1.498.6.1.3.1.1.14
The time in seconds when receiving a continuous AIS signal before a remotely initiated loopback is terminated. When this object has the value 4, then there is no time limit and the loop must be terminated by remotely issued in-band loopdown codes. When the object has a value between 5 and 60, then this is time in seconds of continuous AIS signal before the loopback is terminated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..60  

gdcDsx1InbandLoopCfg 1.3.6.1.4.1.498.6.1.3.1.1.15
This variable is used to set the In-Band DS1 Loopback Code Detection. 'inhibit' refers to when the in-band loopback codes are ignored. 'payload' designates a payload loopback is done upon recognition of the inband loopback code. 'lineloop' designates a line loopback is done upon recognition of the inband loopback code.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inhibit(1), payload(2), lineloop(3)  

gdcDsx1Redundancy 1.3.6.1.4.1.498.6.1.3.1.1.16
This variable identifies which unit is the Primary unit and which unit is the Secondary unit. When the value is onLine(1), then the unit is identified as the Primary unit. When the value is backUp(2), then the unit is identified as the Secondary unit. The value keepAlive(3) indicates that a physical strap is enabled on the unit and that the values of onLine(1) and backUp(2) are ignored. The value keepAlive(3) can never be set by network management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER onLine(1), backUp(2), keepAlive(3)  

gdcDsx1DiagTable 1.3.6.1.4.1.498.6.1.4.1
The GDC DS1 Diagnostics table. Information in the entries of this table support diagnostics testing, both active testing via patterns, and passive testing via loopbacks. The information of this table augments the entries in the DS1 Configuration table of the DS1 MIB defined in RFC 1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1DiagEntry

gdcDsx1DiagEntry 1.3.6.1.4.1.498.6.1.4.1.1
The GDC DS1 Diagnostics table entry. The information in this entry augments the information for the corresponding entry in the DS1 Configuration table of the DS1 MIB defined in RFC 1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1DiagEntry  

gdcDsx1DiagIndex 1.3.6.1.4.1.498.6.1.4.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and sub-identifier, which in this case is a network interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1SendCode 1.3.6.1.4.1.498.6.1.4.1.1.2
Augments the dsx1SendCode object from the DS1 MIB of RFC 1406. This object defines other codes that are not defined by dsx1SendCode. The value of other(1) can never be set by management operation. This object and the dsx1SendCode object interoperate. When the value of dsx1SendCode is set to something other than dsx1SendOtherTestPattern(8), then the value of this object is set to other(1). When the value of this object is set to something other than other(1), the the value of dsx1SendCode is set to dsx1SendOtherTestPattern(8). This object and the gdcDsx1ProgPattern object interrelate. When this object is set to the value sendProgPattern(4), the value of the gdcDsx1ProgPattern object is used as the 16 bit user programmable pattern. The values send511PatternWithLT(11), send511PatternWithRT(12), send2047PatternWithLT(13), send2047PatternWithRT(14), sendQRSPatternWithLT(15), sendQRSPatternWithRT(16), sendProgPatternWithLT(17), sendProgPatternWithRT(18), send3in24PatternWithRT(19) indicate that the given pattern test is running in conjunction with a local test (LT) or remote test (RT). gdcDsx1LoopbackConfig is updated to indicate this as well. When one of these tests are running, and dsx1SendCode is set to dsx1SendNoCode(1), both the pattern and the loopback are terminated. However, if dsx1LoopbackConfig is set to dsx1NoLoop(1), and a pattern with LT is in progres, only the loopback portion is terminated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), sendProgPattern(2), send2047pattern(3), sendInbandCode(6), sendInbandCodeReset(7), sendNetworkInterfaceCode(8), sendNtworkInterfaceResetcode(9), sendDS0DelayPattern(10), send511PatternWithLT(11), send511PatternWithRT(12), send2047PatternWithLT(13), send2047PatternWithRT(14), sendQRSPatternWithLT(15), sendQRSPatternWithRT(16), sendProgPatternWithLT(17), sendProgPatternWithRT(18), send3in24PatternWithRT(19)  

gdcDsx1LoopbackConfig 1.3.6.1.4.1.498.6.1.4.1.1.4
Augments the dsx1LoopbackConfig object from the DS1 MIB of RFC 1406. This object defines other loopback configurations that are not defined by dsx1LoopbackConfig. The value of other(1) can never be set by management operation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), localtest(2), ds0(3), cascade(4)  

gdcDsx1DS0Diag 1.3.6.1.4.1.498.6.1.4.1.1.5
Defines a DS0 level diagnostic. Setting this object value to 0 disables a DS0 level diagnostic. Setting this object to a value from 1 to 32 enables a DS0 level diagnostic on the DS0 indicated. Enabling a DS0 level diagnostic bysetting this object to a value from 1 to 32 alters the meaning of the diagnostic test to be specific to the DS0 specified instead of the whole DS1. Note that a DS0 level diagnostic and a DS1 level diagnostic cannot be performed simultaneously.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32  

gdcDsx1TestDuration 1.3.6.1.4.1.498.6.1.4.1.1.6
Selects the duration to run a diagnostic test. The value(1) noLimit signifies that the test should run indefinitely until explicitly terminated. Default value: noLimit (1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noLimit(1), testTime1Min(2), testTime2Mins(3), testTime3Mins(4), testTime4Mins(5), testTime5Mins(6), testTime6Mins(7), testTime7Mins(8), testTime8Mins(9), testTime9Mins(10), testTime10Mins(11), testTime15Mins(12), testTime20Mins(13), testTime25Mins(14), testTime30Mins(15), testTime30Secs(16)  

gdcDsx1TestExecutionStatus 1.3.6.1.4.1.498.6.1.4.1.1.8
This variable reports the status of a test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a test is currently running. testCompleted(4) indicates that a test has run and is completed. testCompletedNotInTest(5) indicates that a test has completed and it is no longer in test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notInTest(1), testInProgress(2), testCompleted(4), testCompletedNotInTest(5)  

gdcDsx1TestExceptions 1.3.6.1.4.1.498.6.1.4.1.1.9
Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the value zero. Then, for each exception, the value associated with the exception is added to the sum. The exception values are: value exception 1 a timed test was preempted so the result cannot be viewed in relation to the test duration 2 the results overflowed so the result cannot be viewed as an absolute value 4 the test was performed while synchronization could not be performed so the result may not be accurate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

gdcDsx1TestResults 1.3.6.1.4.1.498.6.1.4.1.1.10
The results of the last diagnostic test. This can be the current test running or the last completed test. Note that the interpretation of these results may be affected by the value of the gdcDsx1TestExceptions object. The units of the value of this object depend on the type of diagnostic test run. For all cases except a DS0 delay measurement, the units of the value of this object is the number of errors that occurred. For a DS0 delay measurement, the units of the value of this test are milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1048576  

gdcDsx1ANSIperfTable 1.3.6.1.4.1.498.6.1.5.1
The GDC ANSI Performance table. Information in the entries of this table support the ANSI Scheduled Performance Reports. Entries supply information for both inbound and outbound reports for the last 4 seconds.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1ANSIperfEntry

gdcDsx1ANSIperfEntry 1.3.6.1.4.1.498.6.1.5.1.1
The GDC ANSI Performance table entry. The information in this entry presents one of the 4 second periods performance data in either the inbound or outbound direction.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1ANSIperfEntry  

gdcDsx1ANSIperfIndex 1.3.6.1.4.1.498.6.1.5.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a network interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1ANSIdirection 1.3.6.1.4.1.498.6.1.5.1.1.2
Identifies the direction of the report entry. This is either an outbound(1) report or an inbound(2) report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER outbound(1), inbound(2)  

gdcDsx1ANSIseconds 1.3.6.1.4.1.498.6.1.5.1.1.3
Identifies the reporting interval. This has the value 1 to 4 supporting up to the last 4 seconds of performance data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

gdcDsx1ANSICRCerrorEvents 1.3.6.1.4.1.498.6.1.5.1.1.4
Identifies the magnitude of the error events in the interval which this entry represents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noErrors(1), errors1(2), errors2to5(4), errors6to10(8), errors11to100(16), errors101to320(32), errors321orMore(64)  

gdcDsx1ANSIsevereErrors 1.3.6.1.4.1.498.6.1.5.1.1.5
Identifies whether or not any severe errors were detected in the interval which this entry represents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noEventsDetected(1), eventsDetected(2)  

gdcDsx1ANSIframeErrors 1.3.6.1.4.1.498.6.1.5.1.1.6
Identifies whether or not any framing errors were detected in the interval which this entry represents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noEventsDetected(1), eventsDetected(2)  

gdcDsx1ANSIcodeViolations 1.3.6.1.4.1.498.6.1.5.1.1.7
Identifies whether or not any code violations were detected in the interval which this entry represents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noEventsDetected(1), eventsDetected(2)  

gdcDsx1ANSIcontrolledSlips 1.3.6.1.4.1.498.6.1.5.1.1.8
Identifies whether or not any controlled slips were detected in the interval which this entry represents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noEventsDetected(1), eventsDetected(2)  

gdcDsx1ANSIactivePayloadLoops 1.3.6.1.4.1.498.6.1.5.1.1.9
Identifies whether or not any active payload loops were detected in the interval which this entry represents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noEventsDetected(1), eventsDetected(2)  

gdcDsx1CurrentTable 1.3.6.1.4.1.498.6.1.5.2
The gdcDsx1 Current table. This table supplements the entries in the DS1 AT&T performance table of the DS1 MIB defined in RFC1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1CurrentEntry

gdcDsx1CurrentEntry 1.3.6.1.4.1.498.6.1.5.2.1
An entry in the gdcDsx1 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1CurrentEntry  

gdcDsx1CurrentIndex 1.3.6.1.4.1.498.6.1.5.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a network interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1CurrentLOFCs 1.3.6.1.4.1.498.6.1.5.2.1.2
The number of Loss of Frame Counts (LOFCs) encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

gdcDsx1CurrenUserStat 1.3.6.1.4.1.498.6.1.5.2.1.3
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - 2^15 Errored Seconds bit 5 - 2^14 bit 4 - 2^15 Severely Errored Seconds bit 3 - 2^14 bit 2 - 2^15 Bursty Errored Seconds bit 1 - 2^14 bit 0 - 1: New Interval Octet 2 bit 7 - parity bit 6 - 2^13 Errored Seconds bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - parity bit 6 - 2^6 Errored Seconds bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity bit 6 - 2^13 Severely Errored Seconds bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - parity bit 6 - 2^6 Severely Errored Seconds bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity bit 6 - 2^13 Bursty Errored Seconds bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - parity bit 6 - 2^6 Bursty Errored Seconds bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 8 bit 7 - parity bit 6 - f/u bit 5 - f/u bit 4 - 2^15 Unavailable Seconds bit 3 - 2^14 bit 2 - f/u bit 1 - 2^7 Loss of Frame Count bit 0 - 2^7 Controlled Slip Seconds Octet 9 bit 7 - parity bit 6 - 2^13 Unavailable Seconds bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - parity bit 6 - 2^6 Unavailable Seconds bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 11 bit 7 - parity bit 6 - 2^6 Controlled Slip Second bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 12 bit 7 - parity bit 6 - 2^6 Loss of Frame Count bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 13 bit 7 - parity bit 6 - 2^6 Percent Complete bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(13)  

gdcDsx1IntervalTable 1.3.6.1.4.1.498.6.1.5.3
The gdcDsx1 Interval table. This table supplements the entries in the DS1 AT&T performance table of the DS1 MIB defined in RFC1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1IntervalEntry

gdcDsx1IntervalEntry 1.3.6.1.4.1.498.6.1.5.3.1
An entry in the DS1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1IntervalEntry  

gdcDsx1IntervalIndex 1.3.6.1.4.1.498.6.1.5.3.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a network interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1IntervalNumber 1.3.6.1.4.1.498.6.1.5.3.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

gdcDsx1IntervalLOFCs 1.3.6.1.4.1.498.6.1.5.3.1.3
The number of Loss of Frame Counts (LOFCs) encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

gdcDsx1TotalTable 1.3.6.1.4.1.498.6.1.5.4
The DS1 Total table. 24 hour interval. This table supplements the entries in the DS1 AT&T performance table of the DS1 MIB defined in RFC1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1TotalEntry

gdcDsx1TotalEntry 1.3.6.1.4.1.498.6.1.5.4.1
An entry in the DS1 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1TotalEntry  

gdcDsx1TotalIndex 1.3.6.1.4.1.498.6.1.5.4.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a network interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1TotalLOFCs 1.3.6.1.4.1.498.6.1.5.4.1.2
The number of Loss of Frame Counts (LOFCs) encountered by a DS1interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1AlarmData 1.3.6.1.4.1.498.6.2.1
OBJECT IDENTIFIER    

dsx1NoResponseAlm 1.3.6.1.4.1.498.6.2.1.1
OBJECT IDENTIFIER    

dsx1DiagRxErrAlm 1.3.6.1.4.1.498.6.2.1.2
OBJECT IDENTIFIER    

dsx1PowerUpAlm 1.3.6.1.4.1.498.6.2.1.3
OBJECT IDENTIFIER    

dsx1NvRamCorrupt 1.3.6.1.4.1.498.6.2.1.4
OBJECT IDENTIFIER    

dsx1UnitFailure 1.3.6.1.4.1.498.6.2.1.5
OBJECT IDENTIFIER    

dsx1MbiLock 1.3.6.1.4.1.498.6.2.1.6
OBJECT IDENTIFIER    

dsx1LocalPwrFail 1.3.6.1.4.1.498.6.2.1.7
OBJECT IDENTIFIER    

dsx1TimingLoss 1.3.6.1.4.1.498.6.2.1.8
OBJECT IDENTIFIER    

dsx1StatusChange 1.3.6.1.4.1.498.6.2.1.9
OBJECT IDENTIFIER    

dsx1UnsoTest 1.3.6.1.4.1.498.6.2.1.10
OBJECT IDENTIFIER    

dsx1LossOfSignal 1.3.6.1.4.1.498.6.2.1.11
OBJECT IDENTIFIER    

dsx1LossOfFrame 1.3.6.1.4.1.498.6.2.1.12
OBJECT IDENTIFIER    

dsx1Ais 1.3.6.1.4.1.498.6.2.1.13
OBJECT IDENTIFIER    

dsx1ReceivedYellow 1.3.6.1.4.1.498.6.2.1.14
OBJECT IDENTIFIER    

dsx1UnavailSignalState 1.3.6.1.4.1.498.6.2.1.15
OBJECT IDENTIFIER    

dsx1ExcessiveZeros 1.3.6.1.4.1.498.6.2.1.16
OBJECT IDENTIFIER    

dsx1LowAverageDensity 1.3.6.1.4.1.498.6.2.1.17
OBJECT IDENTIFIER    

dsx1ControlledSlips 1.3.6.1.4.1.498.6.2.1.18
OBJECT IDENTIFIER    

dsx1BipolarViolations 1.3.6.1.4.1.498.6.2.1.19
OBJECT IDENTIFIER    

dsx1CrcErrors 1.3.6.1.4.1.498.6.2.1.20
OBJECT IDENTIFIER    

dsx1FallbackTimingActive 1.3.6.1.4.1.498.6.2.1.21
OBJECT IDENTIFIER    

gdcDsx1AlarmConfigTable 1.3.6.1.4.1.498.6.1.6.1
The gdcAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1AlarmConfigEntry

gdcDsx1AlarmConfigEntry 1.3.6.1.4.1.498.6.1.6.1.1
An entry in the GDC Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1AlarmConfigEntry  

gdcDsx1AlarmConfigIndex 1.3.6.1.4.1.498.6.1.6.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1AlarmConfigIdentifier 1.3.6.1.4.1.498.6.1.6.1.1.2
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

gdcDsx1AlarmCountWindow 1.3.6.1.4.1.498.6.1.6.1.1.3
This variable sets/reads the BPV alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Default: disabled(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), last1sec(2), last1min(3), last1hr(4), infinite(5)  

gdcDsx1AlarmCountThreshold 1.3.6.1.4.1.498.6.1.6.1.1.4
This function sets/reads the BPV alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Default: thresGT10(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thresGT10(1), thresGT100(2), thresGT1000(3), thresGT10000(4)  

gdcDsx1AlarmStatusTable 1.3.6.1.4.1.498.6.1.6.2
The gdcDsx1AlarmStatusTable contains entries that report the status of alarms. The status of an alarm consists of the current alarm status, indicating whether or not the alarm condition is in effect, the number of times the alarm has occurred, the time of the first alarm occurrence, and the time of the last alarm occurrence. The structure of the table is such that alarm status is supported on a unit or interface basis, and then on an alarm type basis within the interface. For simplicity sake and to support the reporting of status of all alarms, a unit is treated as an interface in this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GdcDsx1AlarmStatusEntry

gdcDsx1AlarmStatusEntry 1.3.6.1.4.1.498.6.1.6.2.1
An entry in the GDC Alarm Status table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GdcDsx1AlarmStatusEntry  

gdcDsx1AlarmStatusIndex 1.3.6.1.4.1.498.6.1.6.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

gdcDsx1AlarmStatusIdentifier 1.3.6.1.4.1.498.6.1.6.2.1.2
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

gdcDsx1AlarmCount 1.3.6.1.4.1.498.6.1.6.2.1.3
The number of occurrences of this alarm. This objects value is incremented once for each time that the alarm occurs. This count is incremented regardless of whether or not the alarm is masked or is not reporteded because of the threshold configuration. If the network element type does not support this variable, a noSuch will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

gdcDsx1AlarmFirstOccurrence 1.3.6.1.4.1.498.6.1.6.2.1.4
The time at which the alarm first occurred. This is reported as the number of TimeTicks after the interface was initialized. This object along with its companion object, gdcDsx1AlarmLastOccurrence, can be used to provide greater meaning to the value of gdcDsx1AlarmOccurrenceCount by weighing the count over the period of time. If the network element type does not support this variable, a noSuch will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

gdcDsx1AlarmLastOccurrence 1.3.6.1.4.1.498.6.1.6.2.1.5
The time at which the alarm last occurred. This is reported as the number of TimeTicks after the interface was initialized. This object along with its companion object, gdcDsx1AlarmFirstOccurrence, can be used to provide greater meaning to the value of gdcDsx1AlarmOccurrenceCount by weighing the count over the period of time. If the network element type does not support this variable, a noSuch will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks