GDC7616-MIB

File: GDC7616-MIB.mib (56058 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
GDCMACRO-MIB

Imported symbols

enterprises DisplayString OBJECT-TYPE
SCinstance

Defined Types

Uas7616WhatAreYouEntry  
SEQUENCE    
  uas7616WhatAreYouIndex SCinstance
  uas7616CodeRev DisplayString
  uas7616AlarmStatus OCTET STRING
  uas7616SystemTimingGenStatus INTEGER

Uas7616ConfigEntry  
SEQUENCE    
  uas7616ConfigIndex SCinstance
  uas7616TXClockSource INTEGER
  uas7616TerminationType INTEGER
  uas7616ChADataRate INTEGER
  uas7616ChBDataRate INTEGER

Uas7616ControlEntry  
SEQUENCE    
  uas7616ControlIndex SCinstance
  uas7616SoftReset INTEGER
  uas7616EraseConfig INTEGER
  uas7616LEDStatus OCTET STRING
  uas7616InterfaceType INTEGER
  uas7616SysTimingGen INTEGER
  uas7616ResetIntervals INTEGER
  uas7616SysUpTime INTEGER
  uas7616SetRealTime INTEGER
  uas7616ModuleClkSrc INTEGER
  uas7616ResetMajorAlarm INTEGER
  uas7616ResetMinorAlarm INTEGER

Uas7616DiagnosticEntry  
SEQUENCE    
  uas7616DiagnosticIndex SCinstance
  uas7616DiagnosticChnlIndex INTEGER
  uas7616DiagnosticTest INTEGER
  uas7616DiagnosticResetErrorCount INTEGER
  uas7616DiagnosticResults INTEGER

Uas7616AlarmConfigEntry  
SEQUENCE    
  uas7616AlarmConfigIndex SCinstance
  uas7616AlarmConfigIdentifier OBJECT IDENTIFIER
  uas7616AlarmCountWindow INTEGER
  uas7616AlarmCountThreshold INTEGER

Uas7616Current15MinEntry  
SEQUENCE    
  uas7616Current15MinIndex SCinstance
  uas7616Current15MinStat OCTET STRING

Uas7616IntervalEntry  
SEQUENCE    
  uas7616IntervalIndex SCinstance
  uas7616IntervalNumber INTEGER
  uas7616IntervalStat OCTET STRING

Uas7616Current24HrEntry  
SEQUENCE    
  uas7616Current24HrIndex SCinstance
  uas7616Current24HrStat OCTET STRING

Uas7616Recent24HrEntry  
SEQUENCE    
  uas7616Recent24HrIndex SCinstance
  uas7616Recent24HrStat OCTET STRING

Uas7616UnavailableTimeRegEntry  
SEQUENCE    
  uas7616UnavailableTimeRegIndex SCinstance
  uas7616UnavailableTimeRegNumber INTEGER
  uas7616UnavailableTimeRegStart INTEGER
  uas7616UnavailableTimeRegStop INTEGER

Uas7616IntervalMaintenanceEntry  
SEQUENCE    
  uas7616IntervalMaintenanceIndex SCinstance
  uas7616NumberofValidIntervals INTEGER

Uas7616LocalAlarmConfigEntry  
SEQUENCE    
  uas7616LocalAlarmConfigIndex SCinstance
  uas7616LocalLossOfClock INTEGER
  uas7616LocalUAS INTEGER
  uas7616LocalSES INTEGER
  uas7616LocalES INTEGER
  uas7616LocalOutOfSync INTEGER
  uas7616LocalNoSealingCurrent INTEGER
  uas7616LPMajor INTEGER
  uas7616LPMinor INTEGER

Uas7616TSAssignEntry  
SEQUENCE    
  uas7616TSAssignIndex SCinstance
  uas7616ChannelIndex INTEGER
  uas7616Highway INTEGER
  uas7616TimeSlot INTEGER
  uas7616TSCircuitID DisplayString

Uas7616mAlarmConfigEntry  
SEQUENCE    
  uas7616mAlarmConfigIndex SCinstance
  uas7616mAlarmConfigIdentifier OBJECT IDENTIFIER
  uas7616mAlarmCountThreshold INTEGER

Defined Values

gdc 1.3.6.1.4.1.498
OBJECT IDENTIFIER    

bql2 1.3.6.1.4.1.498.12
OBJECT IDENTIFIER    

uas7616 1.3.6.1.4.1.498.12.4
OBJECT IDENTIFIER    

uas7616MIBVersion 1.3.6.1.4.1.498.12.4.1
The version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is a minor revision(0-9), z is a typo revision (0-9) and T indicates the MIB is still a test revision(A-Z). When a release is complete no T should exist.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(5)  

uas7616WhatAreYouTable 1.3.6.1.4.1.498.12.4.2
The GDC 7616 What Are You Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616WhatAreYouEntry

uas7616WhatAreYouEntry 1.3.6.1.4.1.498.12.4.2.1
An entry in the GDC 7616 What Are You table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616WhatAreYouEntry  

uas7616WhatAreYouIndex 1.3.6.1.4.1.498.12.4.2.1.1
This object is the identifier of the 7616 What Are You table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616CodeRev 1.3.6.1.4.1.498.12.4.2.1.2
This function returns the firmware code level. Example A- ,B-
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

uas7616AlarmStatus 1.3.6.1.4.1.498.12.4.2.1.3
The current alarms of the unit without the alarm masks.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

uas7616SystemTimingGenStatus 1.3.6.1.4.1.498.12.4.2.1.4
Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), clk8khz(2), clk4mhz(3), clk8khzand4mhz(4)  

uas7616ConfigTable 1.3.6.1.4.1.498.12.4.3
The GDC 7616 configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616ConfigEntry

uas7616ConfigEntry 1.3.6.1.4.1.498.12.4.3.1
A listing of GDC 2B1Q 7616 options.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616ConfigEntry  

uas7616ConfigIndex 1.3.6.1.4.1.498.12.4.3.1.1
A unique index for the Configuration Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616TXClockSource 1.3.6.1.4.1.498.12.4.3.1.2
Object to select the Transmit Clock Source for the 7616.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER system(1), recovered(2), internal(3)  

uas7616TerminationType 1.3.6.1.4.1.498.12.4.3.1.3
Object to select the Termination Type for the 7616.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nt(1), lt(2)  

uas7616ChADataRate 1.3.6.1.4.1.498.12.4.3.1.4
Object to select the Data Rate on Channel A, Loop n.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER kbps64(1), kbps128(2), inhibit(3)  

uas7616ChBDataRate 1.3.6.1.4.1.498.12.4.3.1.5
Object to select the Data Rate on Channel B, Loop n.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER kbps64(1), inhibit(2)  

uas7616ControlTable 1.3.6.1.4.1.498.12.4.5
The GDC 7616 Control Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616ControlEntry

uas7616ControlEntry 1.3.6.1.4.1.498.12.4.5.1
An entry in the GDC 7616 Control table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616ControlEntry  

uas7616ControlIndex 1.3.6.1.4.1.498.12.4.5.1.1
This object is the identifier of the 7616 Control table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616SoftReset 1.3.6.1.4.1.498.12.4.5.1.2
Forces a soft reset on the network element. The reset selection is write only. The normal selection is read only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), reset(2)  

uas7616EraseConfig 1.3.6.1.4.1.498.12.4.5.1.3
Forces an erase of the stored configuration in the network element. The erase selection is write only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), erase(2)  

uas7616LEDStatus 1.3.6.1.4.1.498.12.4.5.1.4
The GDC 7616 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - not used 1.5 - loop 1 channel A (00 = No Change 01 = Green Active) 1.4 - (10 = Red Solid 11 = RedFlashing ) 1.3 - loop 1 channel B (00 = No Change 01 = Green Active) 1.2 - (10 = Red Solid 11 = RedFlashing ) 1.1 - loop 2 channel A (00 = No Change 01 = Green Active) 1.0 - (10 = Red Solid 11 = RedFlashing ) 2.7 - not used 2.6 - not used 2.5 - loop 2 channel B (00 = No Change 01 = Green Active) 2.4 - (10 = Red Solid 11 = RedFlashing ) 2.3 - loop 3 channel A (00 = No Change 01 = Green Active) 2.2 - (10 = Red Solid 11 = RedFlashing ) 2.1 - loop 3 channel B (00 = No Change 01 = Green Active) 2.0 - (10 = Red Solid 11 = RedFlashing ) 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - alarm led 3.3 - test mode led 3.2 - in service 3.1 - system timing source 3.0 - management response
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

uas7616InterfaceType 1.3.6.1.4.1.498.12.4.5.1.5
Object used to configure the transmission interface type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER diu(1), niu(2), notAssigned(3)  

uas7616SysTimingGen 1.3.6.1.4.1.498.12.4.5.1.6
Selects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(3) - unit is secondary Timig Generator for the shelf. Only 1 unit in the shelf can the primary or secondary timing generator. All other must be none.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), primary(2), secondary(3)  

uas7616ResetIntervals 1.3.6.1.4.1.498.12.4.5.1.7
This variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), normal(2)  

uas7616SysUpTime 1.3.6.1.4.1.498.12.4.5.1.8
This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7616SetRealTime 1.3.6.1.4.1.498.12.4.5.1.9
Number of seconds from midnight Dec 31, 1969.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7616ModuleClkSrc 1.3.6.1.4.1.498.12.4.5.1.10
This variable is used to read or set the Module Clock Source. This variable must be system when uas7616SysTimingGen is set to none. Any of the three selections when uas7616SysTimingGen is set to secondary, and internal or recovered when uas7616SysTimingGen is set to primary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER system(1), internal(2), recovered(3)  

uas7616ResetMajorAlarm 1.3.6.1.4.1.498.12.4.5.1.11
This variable is used to reset alarm per Loop basis.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), norm(2)  

uas7616ResetMinorAlarm 1.3.6.1.4.1.498.12.4.5.1.12
This variable is used to reset alarm per Loop basis.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), norm(2)  

uas7616DiagnosticTable 1.3.6.1.4.1.498.12.4.6
The GDC 7616 diagnostics table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616DiagnosticEntry

uas7616DiagnosticEntry 1.3.6.1.4.1.498.12.4.6.1
A listing of GDC 7616 diagnostic tests
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616DiagnosticEntry  

uas7616DiagnosticIndex 1.3.6.1.4.1.498.12.4.6.1.1
A unique index for the Diagnostic Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616DiagnosticChnlIndex 1.3.6.1.4.1.498.12.4.6.1.2
A unique channel index for the Channel the test will run on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER channelA(1), channelB(2)  

uas7616DiagnosticTest 1.3.6.1.4.1.498.12.4.6.1.3
Selections digitalLoopback(2), patternGenTest(3), and unitTest(4) start the associated test when written. Reading will show which (if any) test is active. Writing a stopTestwill stop the test if any was in progress.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER stopTest(1), digitalLoopback(2), patternGenTest(3), unitTest(4), rdl(5), rdlSelfTest(6)  

uas7616DiagnosticResetErrorCount 1.3.6.1.4.1.498.12.4.6.1.4
This function resets the error count on a given loop and channel. Management will always read a norm(1) and can only write a reset(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

uas7616DiagnosticResults 1.3.6.1.4.1.498.12.4.6.1.5
This function reads the self test results in bit errors. 2^20
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2097153  

uas7616Alarm 1.3.6.1.4.1.498.12.13
OBJECT IDENTIFIER    

uas7616AlarmData 1.3.6.1.4.1.498.12.13.1
OBJECT IDENTIFIER    

uas7616NoResponseAlm 1.3.6.1.4.1.498.12.13.1.1
OBJECT IDENTIFIER    

uas7616DiagRxErrAlm 1.3.6.1.4.1.498.12.13.1.2
OBJECT IDENTIFIER    

uas7616PowerUpAlm 1.3.6.1.4.1.498.12.13.1.3
OBJECT IDENTIFIER    

uas7616LossOfClockAlm 1.3.6.1.4.1.498.12.13.1.4
OBJECT IDENTIFIER    

uas7616LpOutofSyncAlm 1.3.6.1.4.1.498.12.13.1.5
OBJECT IDENTIFIER    

uas7616LpSealingCurrentNoContinuityAlm 1.3.6.1.4.1.498.12.13.1.6
OBJECT IDENTIFIER    

uas7616LpUnavailableSecondAlm 1.3.6.1.4.1.498.12.13.1.7
OBJECT IDENTIFIER    

uas7616LpSeverelyErroredSecondAlm 1.3.6.1.4.1.498.12.13.1.8
OBJECT IDENTIFIER    

uas7616LpErroredSecondAlm 1.3.6.1.4.1.498.12.13.1.9
OBJECT IDENTIFIER    

uas7616AlarmConfigTable 1.3.6.1.4.1.498.12.13.2
The uas7616AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616AlarmConfigEntry

uas7616AlarmConfigEntry 1.3.6.1.4.1.498.12.13.2.1
An entry in the GDC Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616AlarmConfigEntry  

uas7616AlarmConfigIndex 1.3.6.1.4.1.498.12.13.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616AlarmConfigIdentifier 1.3.6.1.4.1.498.12.13.2.1.2
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

uas7616AlarmCountWindow 1.3.6.1.4.1.498.12.13.2.1.3
This variable sets/reads the UAS, SES or ES alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), last1sec(2), last10secs(3), last30secs(4), last1min(5), last15min(6), last1hr(7), last24hrs(8), infinite(9)  

uas7616AlarmCountThreshold 1.3.6.1.4.1.498.12.13.2.1.4
This function sets/reads the UAS, SES or ES alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER occurrence1x(1), occurrence3x(2), occurrence10x(3), occurrence100x(4), occurrence1Kx(5), occurrence10Kx(6)  

uas7616Current15MinTable 1.3.6.1.4.1.498.12.4.8
The 7616 15 Min Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616Current15MinEntry

uas7616Current15MinEntry 1.3.6.1.4.1.498.12.4.8.1
An entry in the 7616 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616Current15MinEntry  

uas7616Current15MinIndex 1.3.6.1.4.1.498.12.4.8.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616Current15MinStat 1.3.6.1.4.1.498.12.4.8.1.2
Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 4 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 6 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(10)  

uas7616IntervalTable 1.3.6.1.4.1.498.12.4.9
The 7616 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616IntervalEntry

uas7616IntervalEntry 1.3.6.1.4.1.498.12.4.9.1
An entry in the Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616IntervalEntry  

uas7616IntervalIndex 1.3.6.1.4.1.498.12.4.9.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616IntervalNumber 1.3.6.1.4.1.498.12.4.9.1.2
The number of Errored Seconds, Unavailable Seconds & Severely Errored Seconds encountered in one of the previous 16, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

uas7616IntervalStat 1.3.6.1.4.1.498.12.4.9.1.3
Returns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Interval Octet 3 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 6 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 7 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 9 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 10 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 11 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(11)  

uas7616Current24HrTable 1.3.6.1.4.1.498.12.4.10
The Current24Hr table. 4 hour interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616Current24HrEntry

uas7616Current24HrEntry 1.3.6.1.4.1.498.12.4.10.1
An entry in the Current24Hr table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616Current24HrEntry  

uas7616Current24HrIndex 1.3.6.1.4.1.498.12.4.10.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616Current24HrStat 1.3.6.1.4.1.498.12.4.10.1.2
Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(14)  

uas7616Recent24HrTable 1.3.6.1.4.1.498.12.4.11
The Recent24Hr table. 4 hour interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616Recent24HrEntry

uas7616Recent24HrEntry 1.3.6.1.4.1.498.12.4.11.1
An entry in the Recent24Hr table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616Recent24HrEntry  

uas7616Recent24HrIndex 1.3.6.1.4.1.498.12.4.11.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616Recent24HrStat 1.3.6.1.4.1.498.12.4.11.1.2
Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) (not available on network element type 30)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(14)  

uas7616UnavailableTimeRegTable 1.3.6.1.4.1.498.12.4.12
The 7616 Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616UnavailableTimeRegEntry

uas7616UnavailableTimeRegEntry 1.3.6.1.4.1.498.12.4.12.1
An entry in the Unavailable Time Register table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616UnavailableTimeRegEntry  

uas7616UnavailableTimeRegIndex 1.3.6.1.4.1.498.12.4.12.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616UnavailableTimeRegNumber 1.3.6.1.4.1.498.12.4.12.1.2
A number between 1 and 6, where the number is the number of the Unavailable Time Register.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

uas7616UnavailableTimeRegStart 1.3.6.1.4.1.498.12.4.12.1.3
Start time of one of the Unavailable Time Registers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7616UnavailableTimeRegStop 1.3.6.1.4.1.498.12.4.12.1.4
Stop time of one of the Unavailable Time Registers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

uas7616IntervalMaintenanceTable 1.3.6.1.4.1.498.12.4.13
The 7616 Loop Interval Maintenance table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616IntervalMaintenanceEntry

uas7616IntervalMaintenanceEntry 1.3.6.1.4.1.498.12.4.13.1
The 7616 Interval Maintenance table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616IntervalMaintenanceEntry  

uas7616IntervalMaintenanceIndex 1.3.6.1.4.1.498.12.4.13.1.1
The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a Loop interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616NumberofValidIntervals 1.3.6.1.4.1.498.12.4.13.1.2
This variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

uas7616LocalAlarmConfigTable 1.3.6.1.4.1.498.12.4.14
The 7616LocalAlarmConfigTable contains entries that configure alarm reporting.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616LocalAlarmConfigEntry

uas7616LocalAlarmConfigEntry 1.3.6.1.4.1.498.12.4.14.1
An entry in the GDC Local Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616LocalAlarmConfigEntry  

uas7616LocalAlarmConfigIndex 1.3.6.1.4.1.498.12.4.14.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616LocalLossOfClock 1.3.6.1.4.1.498.12.4.14.1.2
Disables or enables the Loss of Clock alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7616LocalUAS 1.3.6.1.4.1.498.12.4.14.1.3
Disables or enables the UAS alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7616LocalSES 1.3.6.1.4.1.498.12.4.14.1.4
Disables or enables the SES alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7616LocalES 1.3.6.1.4.1.498.12.4.14.1.5
Disables or enables the ES alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7616LocalOutOfSync 1.3.6.1.4.1.498.12.4.14.1.6
Disables or enables the Out of Sync alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7616LocalNoSealingCurrent 1.3.6.1.4.1.498.12.4.14.1.7
Disables or enables the No Sealing Current alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7616LPMajor 1.3.6.1.4.1.498.12.4.14.1.8
Disables or enables the Major alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7616LPMinor 1.3.6.1.4.1.498.12.4.14.1.9
Disables or enables the Minor alarm on the Minor buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

uas7616TSAssignTable 1.3.6.1.4.1.498.12.4.15
The 7616TSAssignTable contains entries that provide a means to assign a highway and time slot of that highway to the channel of a loop.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616TSAssignEntry

uas7616TSAssignEntry 1.3.6.1.4.1.498.12.4.15.1
An entry in the GDC Circuit Identification table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616TSAssignEntry  

uas7616TSAssignIndex 1.3.6.1.4.1.498.12.4.15.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616ChannelIndex 1.3.6.1.4.1.498.12.4.15.1.2
The index value which uniquely identifies the channel of the interface to which this entry is applicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER channelA(1), channelB(2)  

uas7616Highway 1.3.6.1.4.1.498.12.4.15.1.3
Defines the highway the channel of the loop is assigned to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notAssigned(1), highway1(2), highway2(3), highway3(4), highway4(5)  

uas7616TimeSlot 1.3.6.1.4.1.498.12.4.15.1.4
Defines the time slot of the highway the channel of the loop is assigned to. Valid range is 1 to 31. A value of 64 indicates the channel is not assigned to a highway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..64  

uas7616TSCircuitID 1.3.6.1.4.1.498.12.4.15.1.5
Name to identify the circuit for the channel of this loop.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

uas7616mAlarm 1.3.6.1.4.1.498.12.14
OBJECT IDENTIFIER    

uas7616mAlarmData 1.3.6.1.4.1.498.12.14.1
OBJECT IDENTIFIER    

uas7616mNoResponseAlm 1.3.6.1.4.1.498.12.14.1.1
OBJECT IDENTIFIER    

uas7616mDiagRxErrAlm 1.3.6.1.4.1.498.12.14.1.2
OBJECT IDENTIFIER    

uas7616mPowerUpAlm 1.3.6.1.4.1.498.12.14.1.3
OBJECT IDENTIFIER    

uas7616mLossOfClockAlm 1.3.6.1.4.1.498.12.14.1.4
OBJECT IDENTIFIER    

uas7616mLpOutofSyncAlm 1.3.6.1.4.1.498.12.14.1.5
OBJECT IDENTIFIER    

uas7616mLpSealingCurrentNoContinuityAlm 1.3.6.1.4.1.498.12.14.1.6
OBJECT IDENTIFIER    

uas7616mLpUnavailableSecondAlm 1.3.6.1.4.1.498.12.14.1.7
OBJECT IDENTIFIER    

uas7616mLpErroredSecondAlm 1.3.6.1.4.1.498.12.14.1.8
OBJECT IDENTIFIER    

uas7616mLPMajorAlm 1.3.6.1.4.1.498.12.14.1.9
OBJECT IDENTIFIER    

uas7616mLPMinorAlm 1.3.6.1.4.1.498.12.14.1.10
OBJECT IDENTIFIER    

uas7616mAlarmConfigTable 1.3.6.1.4.1.498.12.14.2
The uas7616mAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Uas7616mAlarmConfigEntry

uas7616mAlarmConfigEntry 1.3.6.1.4.1.498.12.14.2.1
An entry in the GDC Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Uas7616mAlarmConfigEntry  

uas7616mAlarmConfigIndex 1.3.6.1.4.1.498.12.14.2.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

uas7616mAlarmConfigIdentifier 1.3.6.1.4.1.498.12.14.2.1.2
The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

uas7616mAlarmCountThreshold 1.3.6.1.4.1.498.12.14.2.1.3
This function sets/reads the Major or Minor BER alarm threshold criteria.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thres10E03(1), thres10E04(2), thres10E05(3), thres10E06(4)