Fore-Sonet-Ext-MIB

File: Fore-Sonet-Ext-MIB.mib (91206 bytes)

Imported modules

SNMPv2-SMI Fore-Common-MIB IF-MIB
Fore-TrapLog-MIB SONET-MIB

Imported symbols

Integer32 Counter32 OBJECT-TYPE
NOTIFICATION-TYPE MODULE-IDENTITY asx
ifIndex ifName trapLogIndex
sonetSectionIntervalNumber sonetLineIntervalNumber sonetFarEndLineIntervalNumber
sonetPathIntervalNumber sonetFarEndPathIntervalNumber sonetVTIntervalNumber
sonetFarEndVTIntervalNumber

Defined Types

ForeSonetMediumConfigEntry  
SEQUENCE    
  foreSonetMediumConfigLoopbackMode INTEGER
  foreSonetMediumConfigTxClockSource INTEGER

ForeSonetSectionTotalEntry  
SEQUENCE    
  foreSonetSectionTotalBIPs Counter32
  foreSonetSectionTotalLOSs Counter32
  foreSonetSectionTotalLOFs Counter32

ForeSonetSectionDiagnosticsEntry  
SEQUENCE    
  foreSonetSectionDiagnosticsFraming INTEGER
  foreSonetSectionDiagnosticsB1 INTEGER
  foreSonetSectionDiagnosticsDisableTxScrambling INTEGER
  foreSonetSectionDiagnosticsDisableRxDescrambling INTEGER
  foreSonetSectionDiagnosticsLOS INTEGER

ForeSonetSectionCurrentEntry  
SEQUENCE    
  foreSonetSectionCurrentBBEs Integer32

ForeSonetSectionIntervalEntry  
SEQUENCE    
  foreSonetSectionIntervalBBEs Integer32
  foreSonetSectionIntervalESR Integer32
  foreSonetSectionIntervalSESR Integer32
  foreSonetSectionIntervalBBER Integer32

ForeSonetLineCurrentEntry  
SEQUENCE    
  foreSonetLineCurrentBBEs Integer32

ForeSonetLineIntervalEntry  
SEQUENCE    
  foreSonetLineIntervalBBEs Integer32
  foreSonetLineIntervalESR Integer32
  foreSonetLineIntervalSESR Integer32
  foreSonetLineIntervalBBER Integer32

ForeSonetFarEndLineCurrentEntry  
SEQUENCE    
  foreSonetFarEndLineCurrentBBEs Integer32

ForeSonetFarEndLineIntervalEntry  
SEQUENCE    
  foreSonetFarEndLineIntervalBBEs Integer32
  foreSonetFarEndLineIntervalESR Integer32
  foreSonetFarEndLineIntervalSESR Integer32
  foreSonetFarEndLineIntervalBBER Integer32

ForeSonetPathIntervalEntry  
SEQUENCE    
  foreSonetPathIntervalBBEs Integer32
  foreSonetPathIntervalESR Integer32
  foreSonetPathIntervalSESR Integer32
  foreSonetPathIntervalBBER Integer32

ForeSonetFarEndPathCurrentEntry  
SEQUENCE    
  foreSonetFarEndPathCurrentBBEs Integer32

ForeSonetFarEndPathIntervalEntry  
SEQUENCE    
  foreSonetFarEndPathIntervalBBEs Integer32
  foreSonetFarEndPathIntervalESR Integer32
  foreSonetFarEndPathIntervalSESR Integer32
  foreSonetFarEndPathIntervalBBER Integer32

ForeSonetVTCurrentEntry  
SEQUENCE    
  foreSonetVTCurrentBBEs Integer32

ForeSonetVTIntervalEntry  
SEQUENCE    
  foreSonetVTIntervalBBEs Integer32
  foreSonetVTIntervalESR Integer32
  foreSonetVTIntervalSESR Integer32
  foreSonetVTIntervalBBER Integer32

ForeSonetFarEndVTCurrentEntry  
SEQUENCE    
  foreSonetFarEndVTCurrentBBEs Integer32

ForeSonetFarEndVTIntervalEntry  
SEQUENCE    
  foreSonetFarEndVTIntervalBBEs Integer32
  foreSonetFarEndVTIntervalESR Integer32
  foreSonetFarEndVTIntervalSESR Integer32
  foreSonetFarEndVTIntervalBBER Integer32

ForeSonetLineConfigEntry  
SEQUENCE    
  foreSonetLineBipThrSeconds Integer32
  foreSonetLineBipThrErrors Integer32
  foreSonetLineBipFailEnable INTEGER
  foreSonetLineSignalDegradeBer Integer32
  foreSonetLineSignalFailBer Integer32
  foreSonetLineBerErrorModel INTEGER
  foreSonetLineBerState INTEGER

ForeSonetLineTotalEntry  
SEQUENCE    
  foreSonetLineTotalBIPs Counter32
  foreSonetLineTotalFEBEs Counter32
  foreSonetLineTotalAISs Counter32
  foreSonetLineTotalRDIs Counter32

ForeSonetLineDiagnosticsEntry  
SEQUENCE    
  foreSonetLineDiagnosticsLAIS INTEGER
  foreSonetLineDiagnosticsB2 INTEGER
  foreSonetLineDiagnosticsAPS INTEGER
  foreSonetLineDiagnosticsK1channel INTEGER
  foreSonetLineDiagnosticsK1request INTEGER
  foreSonetLineDiagnosticsK2channel INTEGER
  foreSonetLineDiagnosticsK2Architecture INTEGER
  foreSonetLineDiagnosticsK2Mode INTEGER
  foreSonetLineDiagnosticsLRDI INTEGER
  foreSonetLineDiagnosticsLREI INTEGER

ForeSonetPathConfigEntry  
SEQUENCE    
  foreSonetPathRxSignalLabel Integer32
  foreSonetPathTxSignalLabel Integer32
  foreSonetPathLoopbackMode INTEGER

ForeSonetPathTotalEntry  
SEQUENCE    
  foreSonetPathTotalBIPs Counter32
  foreSonetPathTotalLOPs Counter32
  foreSonetPathTotalAISs Counter32
  foreSonetPathTotalRDIs Counter32
  foreSonetPathTotalUNEQs Counter32
  foreSonetPathTotalPLMs Counter32
  foreSonetPathTotalFEBEs Counter32

ForeSonetPathCurrentEntry  
SEQUENCE    
  foreSonetPathCurrentStatus Integer32
  foreSonetPathCurrentBBEs Integer32

ForeSonetPathDiagnosticsEntry  
SEQUENCE    
  foreSonetPathDiagnosticsC2 INTEGER
  foreSonetPathDiagnosticsC2Value INTEGER
  foreSonetPathDiagnosticsB3 INTEGER
  foreSonetPathDiagnosticsPREI INTEGER
  foreSonetPathDiagnosticsPAIS INTEGER
  foreSonetPathDiagnosticsPERDI INTEGER
  foreSonetPathDiagnosticsERDIValue INTEGER
  foreSonetPathDiagnosticsLOP INTEGER

ForeSonetPathGroupConfigEntry  
SEQUENCE    
  foreVTGroup Integer32
  foreVTWidth INTEGER

ForeSonetVTConfigEntry  
SEQUENCE    
  foreSonetVTLoopbackMode INTEGER

ForeSonetVTTotalEntry  
SEQUENCE    
  foreSonetVTTotalBIPs Counter32
  foreSonetVTTotalREIs Counter32
  foreSonetVTTotalLOPs Counter32
  foreSonetVTTotalAISs Counter32
  foreSonetVTTotalRDIs Counter32
  foreSonetVTTotalUNEQs Counter32
  foreSonetVTTotalPLMs Counter32

ForeSonetVTDiagnosticsEntry  
SEQUENCE    
  foreSonetVtDiagnosticsBIP INTEGER
  foreSonetVtDiagnosticsRDI INTEGER
  foreSonetVtDiagnosticsRFI INTEGER
  foreSonetVtDiagnosticsAIS INTEGER
  foreSonetVtDiagnosticsLOP INTEGER
  foreSonetVtDiagnosticsLabel INTEGER
  foreSonetVtDiagnosticsLabelValue INTEGER
  foreSonetVtDiagnosticsREI INTEGER

Defined Values

foreSonetMib 1.3.6.1.4.1.326.2.2.1.1.14
This mib implements extensions to the standard SONET mib to support extra configuration and statistics that are supported by Fore Systems.
MODULE-IDENTITY    

foreSonetMedium 1.3.6.1.4.1.326.2.2.1.1.14.1
OBJECT IDENTIFIER    

foreSonetSection 1.3.6.1.4.1.326.2.2.1.1.14.2
OBJECT IDENTIFIER    

foreSonetLine 1.3.6.1.4.1.326.2.2.1.1.14.3
OBJECT IDENTIFIER    

foreSonetPath 1.3.6.1.4.1.326.2.2.1.1.14.4
OBJECT IDENTIFIER    

foreSonetVT 1.3.6.1.4.1.326.2.2.1.1.14.5
OBJECT IDENTIFIER    

foreSonetSPE 1.3.6.1.4.1.326.2.2.1.1.14.6
OBJECT IDENTIFIER    

foreSonetFarEndLine 1.3.6.1.4.1.326.2.2.1.1.14.7
OBJECT IDENTIFIER    

foreSonetFarEndPath 1.3.6.1.4.1.326.2.2.1.1.14.8
OBJECT IDENTIFIER    

foreSonetFarEndVT 1.3.6.1.4.1.326.2.2.1.1.14.9
OBJECT IDENTIFIER    

foreSonetMediumConfigTable 1.3.6.1.4.1.326.2.2.1.1.14.1.1
A table of configuration options and statistics that extend the Sonet Medium Group in the Standard SONET MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetMediumConfigEntry

foreSonetMediumConfigEntry 1.3.6.1.4.1.326.2.2.1.1.14.1.1.1
A table entry containing Fore specific extensions to the standard SONET Medium Group Tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetMediumConfigEntry  

foreSonetMediumConfigLoopbackMode 1.3.6.1.4.1.326.2.2.1.1.14.1.1.1.1
This variable represents the current loopback status of the SONET interface. The possible values are: sonetNoLoop (1) means that the interface is not in a loopback state. sonetLineLoop (2) means that the receive data and clock are connected to the transmit data and clock. sonetDiagLoop (3) means that the transmit data stream and clock are looped back to the receiver. sonetOtherLoop (4) means that the interface is in a loopback that is not defined here.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sonetNoLoop(1), sonetLineLoop(2), sonetDiagLoop(3), sonetOtherLoop(4)  

foreSonetMediumConfigTxClockSource 1.3.6.1.4.1.326.2.2.1.1.14.1.1.1.2
The source of the transmit clock.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER rxTiming(1), localTiming(2)  

foreSonetSectionTotalTable 1.3.6.1.4.1.326.2.2.1.1.14.2.2
A table of configuration options and statistics that extend the standard Sonet section tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetSectionTotalEntry

foreSonetSectionTotalEntry 1.3.6.1.4.1.326.2.2.1.1.14.2.2.1
A table entry containing Fore specific extensions to the standard SONET section table statistics.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetSectionTotalEntry  

foreSonetSectionTotalBIPs 1.3.6.1.4.1.326.2.2.1.1.14.2.2.1.1
The number of Section BIP-8 (Bit Interleaved Parity) errors that have been detected since the last time the port has been reset. The calculated BIP-8 code is compared with the BIP-8 code extracted from the B1 byte of the following frame. Differences indicate that a section level bit error has occurred.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetSectionTotalLOSs 1.3.6.1.4.1.326.2.2.1.1.14.2.2.1.2
The number of seconds in which Loss Of Signal (LOS) has occurred. A LOS is declared when 20 +/- 3us of all zeros patterns is detected. LOS is cleared when two valid framing words are detected and during the intervening time no LOS condition is detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetSectionTotalLOFs 1.3.6.1.4.1.326.2.2.1.1.14.2.2.1.3
The number of seconds in which Loss Of Frame (LOF) has occurred. A LOF is declared when an out-of-frame (OOF) condition persists for 3ms. The LOF is cleared when an in-frame condition persists for 3ms. While in-frame the framing bytes (A1, A2) in each frame are compared against the expected pattern. Out-of-frame is declared when four consecutive frames containing one or more framing pattern errors have been received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetSectionDiagnosticsTable 1.3.6.1.4.1.326.2.2.1.1.14.2.3
A table of configuration options and statistics that extend the standard Sonet Section tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetSectionDiagnosticsEntry

foreSonetSectionDiagnosticsEntry 1.3.6.1.4.1.326.2.2.1.1.14.2.3.1
A table entry containing Fore specific extensions to the standard SONET Section tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetSectionDiagnosticsEntry  

foreSonetSectionDiagnosticsFraming 1.3.6.1.4.1.326.2.2.1.1.14.2.3.1.1
Controls the insertion of framing (A1 A2 byte) errors. off When set to off, transmit Sonet frames continously with no A1A2 errors (framing errors). on When set to on, transmit Sonet frames continously with bad A1A2 values. momentary When set to momentary, transmit a chip dependent number of Sonet frames with A1A2 errors.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), momentary(3)  

foreSonetSectionDiagnosticsB1 1.3.6.1.4.1.326.2.2.1.1.14.2.3.1.2
Controls the insertion of BIP errors in the sonet section B1 byte overhead. off When set to off, do not generate section BIP errors. on When set to on, generate section BIP errors. momentary When set to momentary, transmit a chip dependent number of Sonet frames with section BIP errors.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), momentary(3)  

foreSonetSectionDiagnosticsDisableTxScrambling 1.3.6.1.4.1.326.2.2.1.1.14.2.3.1.3
Controls the scrambling of sonet overhead and SPE of the transmitted Sonet frame. off When set to off, transmitted Sonet frames are scrambled. on When set to on, transmitted Sonet frames are NOT scrambled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

foreSonetSectionDiagnosticsDisableRxDescrambling 1.3.6.1.4.1.326.2.2.1.1.14.2.3.1.4
Controls the descrambling of sonet overhead and SPE of the received Sonet frame. off When set to off, received Sonet frames are descrambled. on When set to on, received Sonet frames are NOT descrambled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

foreSonetSectionDiagnosticsLOS 1.3.6.1.4.1.326.2.2.1.1.14.2.3.1.5
Controls the insertion of Loss of Signal (LOS) errors in the transmitted Sonet frame. off When set to off, do not generate LOS errors. on When set to on, generate LOS errors.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

foreSonetSectionCurrentTable 1.3.6.1.4.1.326.2.2.1.1.14.2.4
The Fore's extension to SONET/SDH Section Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetSectionCurrentEntry

foreSonetSectionCurrentEntry 1.3.6.1.4.1.326.2.2.1.1.14.2.4.1
An entry in the SONET/SDH Section Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetSectionCurrentEntry  

foreSonetSectionCurrentBBEs 1.3.6.1.4.1.326.2.2.1.1.14.2.4.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH Section in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetSectionIntervalTable 1.3.6.1.4.1.326.2.2.1.1.14.2.5
The Fore's extension to SONET/SDH Section Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetSectionIntervalEntry

foreSonetSectionIntervalEntry 1.3.6.1.4.1.326.2.2.1.1.14.2.5.1
An entry in the SONET/SDH Section Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetSectionIntervalEntry  

foreSonetSectionIntervalBBEs 1.3.6.1.4.1.326.2.2.1.1.14.2.5.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetSectionIntervalESR 1.3.6.1.4.1.326.2.2.1.1.14.2.5.1.2
The ratio of Errored seconds encountered by a SONET/SDH Section to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetSectionIntervalSESR 1.3.6.1.4.1.326.2.2.1.1.14.2.5.1.3
The ratio of Sev Errored seconds encountered by a SONET/SDH Section to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetSectionIntervalBBER 1.3.6.1.4.1.326.2.2.1.1.14.2.5.1.4
The ratio of Background blk errors encountered by a SONET/SDH Section to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetLineCurrentTable 1.3.6.1.4.1.326.2.2.1.1.14.3.4
The Fore's extension to SONET/SDH Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetLineCurrentEntry

foreSonetLineCurrentEntry 1.3.6.1.4.1.326.2.2.1.1.14.3.4.1
An entry in the SONET/SDH Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetLineCurrentEntry  

foreSonetLineCurrentBBEs 1.3.6.1.4.1.326.2.2.1.1.14.3.4.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH Line in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetLineIntervalTable 1.3.6.1.4.1.326.2.2.1.1.14.3.5
The Fore's extension to SONET/SDH Line Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetLineIntervalEntry

foreSonetLineIntervalEntry 1.3.6.1.4.1.326.2.2.1.1.14.3.5.1
An entry in the SONET/SDH Line Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetLineIntervalEntry  

foreSonetLineIntervalBBEs 1.3.6.1.4.1.326.2.2.1.1.14.3.5.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetLineIntervalESR 1.3.6.1.4.1.326.2.2.1.1.14.3.5.1.2
The ratio of Errored seconds encountered by a SONET/SDH Line to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetLineIntervalSESR 1.3.6.1.4.1.326.2.2.1.1.14.3.5.1.3
The ratio of Sev Errored seconds encountered by a SONET/SDH Line to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetLineIntervalBBER 1.3.6.1.4.1.326.2.2.1.1.14.3.5.1.4
The ratio of Background blk errors encountered by a SONET/SDH Line to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndLineCurrentTable 1.3.6.1.4.1.326.2.2.1.1.14.7.1
The Fore's extension to SONET/SDH Farend Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetFarEndLineCurrentEntry

foreSonetFarEndLineCurrentEntry 1.3.6.1.4.1.326.2.2.1.1.14.7.1.1
An entry in the SONET/SDH FarEnd Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetFarEndLineCurrentEntry  

foreSonetFarEndLineCurrentBBEs 1.3.6.1.4.1.326.2.2.1.1.14.7.1.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH FarEnd Line in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndLineIntervalTable 1.3.6.1.4.1.326.2.2.1.1.14.7.2
The Fore's extension to SONET/SDH FarEndLine Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetFarEndLineIntervalEntry

foreSonetFarEndLineIntervalEntry 1.3.6.1.4.1.326.2.2.1.1.14.7.2.1
An entry in the SONET/SDH FarEndLine Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetFarEndLineIntervalEntry  

foreSonetFarEndLineIntervalBBEs 1.3.6.1.4.1.326.2.2.1.1.14.7.2.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH FarEndLine in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndLineIntervalESR 1.3.6.1.4.1.326.2.2.1.1.14.7.2.1.2
The ratio of Errored seconds encountered by a SONET/SDH FarEndLine to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndLineIntervalSESR 1.3.6.1.4.1.326.2.2.1.1.14.7.2.1.3
The ratio of Sev Errored seconds encountered by a SONET/SDH FarEndLine to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndLineIntervalBBER 1.3.6.1.4.1.326.2.2.1.1.14.7.2.1.4
The ratio of Background blk errors encountered by a SONET/SDH FarEndLine to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetPathIntervalTable 1.3.6.1.4.1.326.2.2.1.1.14.4.6
The Fore's extension to SONET/SDH Path Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetPathIntervalEntry

foreSonetPathIntervalEntry 1.3.6.1.4.1.326.2.2.1.1.14.4.6.1
An entry in the SONET/SDH Path Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetPathIntervalEntry  

foreSonetPathIntervalBBEs 1.3.6.1.4.1.326.2.2.1.1.14.4.6.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH Path in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetPathIntervalESR 1.3.6.1.4.1.326.2.2.1.1.14.4.6.1.2
The ratio of Errored seconds encountered by a SONET/SDH Path to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetPathIntervalSESR 1.3.6.1.4.1.326.2.2.1.1.14.4.6.1.3
The ratio of Sev Errored seconds encountered by a SONET/SDH Path to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetPathIntervalBBER 1.3.6.1.4.1.326.2.2.1.1.14.4.6.1.4
The ratio of Background blk errors encountered by a SONET/SDH Path to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndPathCurrentTable 1.3.6.1.4.1.326.2.2.1.1.14.8.1
The Fore's extension to SONET/SDH FarEnd Path Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetFarEndPathCurrentEntry

foreSonetFarEndPathCurrentEntry 1.3.6.1.4.1.326.2.2.1.1.14.8.1.1
An entry in the SONET/SDH FarEnd Path Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetFarEndPathCurrentEntry  

foreSonetFarEndPathCurrentBBEs 1.3.6.1.4.1.326.2.2.1.1.14.8.1.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH FarEnd Path in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndPathIntervalTable 1.3.6.1.4.1.326.2.2.1.1.14.8.2
The Fore's extension to SONET/SDH FarEndPath Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetFarEndPathIntervalEntry

foreSonetFarEndPathIntervalEntry 1.3.6.1.4.1.326.2.2.1.1.14.8.2.1
An entry in the SONET/SDH FarEndPath Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetFarEndPathIntervalEntry  

foreSonetFarEndPathIntervalBBEs 1.3.6.1.4.1.326.2.2.1.1.14.8.2.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH FarEndPath in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndPathIntervalESR 1.3.6.1.4.1.326.2.2.1.1.14.8.2.1.2
The ratio of Errored seconds encountered by a SONET/SDH FarEndPath to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndPathIntervalSESR 1.3.6.1.4.1.326.2.2.1.1.14.8.2.1.3
The ratio of Sev Errored seconds encountered by a SONET/SDH FarEndPath to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndPathIntervalBBER 1.3.6.1.4.1.326.2.2.1.1.14.8.2.1.4
The ratio of Background blk errors encountered by a SONET/SDH FarEndPath to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetVTCurrentTable 1.3.6.1.4.1.326.2.2.1.1.14.5.4
The Fore's extension to SONET/SDH VT Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetVTCurrentEntry

foreSonetVTCurrentEntry 1.3.6.1.4.1.326.2.2.1.1.14.5.4.1
An entry in the SONET/SDH VT Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetVTCurrentEntry  

foreSonetVTCurrentBBEs 1.3.6.1.4.1.326.2.2.1.1.14.5.4.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH VT in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetVTIntervalTable 1.3.6.1.4.1.326.2.2.1.1.14.5.5
The Fore's extension to SONET/SDH VT Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetVTIntervalEntry

foreSonetVTIntervalEntry 1.3.6.1.4.1.326.2.2.1.1.14.5.5.1
An entry in the SONET/SDH VT Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetVTIntervalEntry  

foreSonetVTIntervalBBEs 1.3.6.1.4.1.326.2.2.1.1.14.5.5.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH VT in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetVTIntervalESR 1.3.6.1.4.1.326.2.2.1.1.14.5.5.1.2
The ratio of Errored seconds encountered by a SONET/SDH Section to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetVTIntervalSESR 1.3.6.1.4.1.326.2.2.1.1.14.5.5.1.3
The ratio of Sev Errored seconds encountered by a SONET/SDH Section to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetVTIntervalBBER 1.3.6.1.4.1.326.2.2.1.1.14.5.5.1.4
The ratio of Background blk errors encountered by a SONET/SDH Section to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndVTCurrentTable 1.3.6.1.4.1.326.2.2.1.1.14.9.1
The Fore's extension to SONET/SDH Farend VT Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetFarEndVTCurrentEntry

foreSonetFarEndVTCurrentEntry 1.3.6.1.4.1.326.2.2.1.1.14.9.1.1
An entry in the SONET/SDH FarEnd VT Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetFarEndVTCurrentEntry  

foreSonetFarEndVTCurrentBBEs 1.3.6.1.4.1.326.2.2.1.1.14.9.1.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH FarEnd VT in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndVTIntervalTable 1.3.6.1.4.1.326.2.2.1.1.14.9.2
The Fore's extension to SONET/SDH FarEndVT Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetFarEndVTIntervalEntry

foreSonetFarEndVTIntervalEntry 1.3.6.1.4.1.326.2.2.1.1.14.9.2.1
An entry in the SONET/SDH FarEndVT Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetFarEndVTIntervalEntry  

foreSonetFarEndVTIntervalBBEs 1.3.6.1.4.1.326.2.2.1.1.14.9.2.1.1
The counter associated with the number of Background Errors encountered by a SONET/SDH FarEndVT in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndVTIntervalESR 1.3.6.1.4.1.326.2.2.1.1.14.9.2.1.2
The ratio of Errored seconds encountered by a SONET/SDH FarEndVT to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndVTIntervalSESR 1.3.6.1.4.1.326.2.2.1.1.14.9.2.1.3
The ratio of Sev Errored seconds encountered by a SONET/SDH FarEndVT to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetFarEndVTIntervalBBER 1.3.6.1.4.1.326.2.2.1.1.14.9.2.1.4
The ratio of Background blk errors encountered by a SONET/SDH FarEndVT to time in a particular 15-minute interval in the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetLineConfigTable 1.3.6.1.4.1.326.2.2.1.1.14.3.1
A table of configuration options and statistics that extend the Sonet Line Group in the Standard SONET MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetLineConfigEntry

foreSonetLineConfigEntry 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1
A table entry containing Fore specific extensions to the standard SONET Line Group Tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetLineConfigEntry  

foreSonetLineBipThrSeconds 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.2
This variable represents the consecutive number of BAD/GOOD seconds to detect/clear a B2 byte Line Bit Interleaved Parity (BIP) Defect. The range of the values it can take is between 2 and 10 inclusive.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

foreSonetLineBipThrErrors 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.3
This variable is a threshold for the number of B2 byte Line Bit Interleaved Parity (BIP) Errors per second and is used as a parameter to the Line BIP Defect. If the number of errors exceeds the threshold, the particular second is declared BAD, otherwise it is declared GOOD.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

foreSonetLineBipFailEnable 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.4
This variable controls whether declaration of a Line BIP Defect forces the port's operState to Down.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

foreSonetLineSignalDegradeBer 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.5
This is the exponent of 10 for the current signal degrade bit error rate (BER) threshold for this port. The value -7, for example, represents a BER of 1E-7. This variable is only applicable when sonetLineBerErrorModel is set to errorModelRandom.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

foreSonetLineSignalFailBer 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.6
This is the exponent of 10 for the current signal fail bit error rate (BER) threshold for this port. The value -4, for example, represents a BER of 1E-4. This variable is only applicable when sonetLineBerErrorModel is set to errorModelRandom.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

foreSonetLineBerErrorModel 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.7
This is the error distribution model to be used to identify signal degrade and signal fail conditions. errorModelRandom selects a random error distribution and declares signal conditions based on the thresholds set in sonetLineSignalDegradeBer and sonetLineSignalFailBer. errorModelBurst selects a burst error model and declares signal degrade conditions based on the thresholds set in sonetLineBipThrSeconds and sonetLineBipThrErrors. errorModelNone disables detection of signal conditions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER errorModelNone(0), errorModelRandom(1), errorModelBurst(2)  

foreSonetLineBerState 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.8
This value describes the current state of the port as determined through bit error rate analysis.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER berStateOk(0), berStateSigDegrade(1), berStateSigFail(2)  

foreSonetLineTotalTable 1.3.6.1.4.1.326.2.2.1.1.14.3.2
A table of configuration options and statistics that extend the Sonet Line Group in the Standard SONET MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetLineTotalEntry

foreSonetLineTotalEntry 1.3.6.1.4.1.326.2.2.1.1.14.3.2.1
A table entry containing Fore specific extensions to the standard SONET Line Group Tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetLineTotalEntry  

foreSonetLineTotalBIPs 1.3.6.1.4.1.326.2.2.1.1.14.3.2.1.1
The number of Line BIP-24 (Bit Interleaved Parity) errors that have been detected since the last time the port has been reset. The calculated BIP-24 code is based on the line overhead and synchronous payload envelope (SPE) of the STS-3c stream. The line BIP-24 code is a bit interleaved parity calculation using even parity. The calculated code is compared with the BIP-24 code extracted from the B2 bytes of the following frame. Differences indicate that a line layer bit error has occurred.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetLineTotalFEBEs 1.3.6.1.4.1.326.2.2.1.1.14.3.2.1.2
The number of line Far End Block Errors (FEBE) that have been detected since the last time the port has been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetLineTotalAISs 1.3.6.1.4.1.326.2.2.1.1.14.3.2.1.3
The number of seconds in which line Alarm Indication Signal (AIS) has occurred. A line AIS is asserted when a 111 binary pattern is detected in bits 6,7,8 of the K2 byte for five consecutive frames. A line AIS is removed when any pattern other than 111 is detected in these bits for five consecutive frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetLineTotalRDIs 1.3.6.1.4.1.326.2.2.1.1.14.3.2.1.4
The number of seconds in which line Far End Receive Failure (RDI) has occurred. A line RDI is asserted when a 110 binary pattern is detected in bits 6,7,8 of the K2 byte for five consecutive frames. A line RDI is removed when any pattern other than 110 is detected in these bits for five consecutive frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetLineDiagnosticsTable 1.3.6.1.4.1.326.2.2.1.1.14.3.3
A table of configuration options and statistics that extend the Sonet Line Group in the Standard SONET MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetLineDiagnosticsEntry

foreSonetLineDiagnosticsEntry 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1
A table entry containing Fore specific extensions to the standard SONET Line Group Tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetLineDiagnosticsEntry  

foreSonetLineDiagnosticsLAIS 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.1
Controls the insertion of line alarm indication signal (AIS_L). on When set to on, all bits of the SONET frame are set to 1 except for the section overhead. off resume normal operation
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

foreSonetLineDiagnosticsB2 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.2
Controls the insertion of BIP errors in the sonet line B2 byte overhead. off When set to off, do not generate line BIP errors. on When set to on, generate line BIP errors. momentary When set to momentary, transmit a chip dependent number of Sonet frame with line BIP errors.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), momentary(3)  

foreSonetLineDiagnosticsAPS 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.3
Controls the insertion of line APS bytes (K1 and K2) that are determined by normal operating rules or by diagnostic mibs. off When set to off, resume normal operation. on When set to on, K1 and K2 bytes are calculated by contents of diagnostic mibs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

foreSonetLineDiagnosticsK1channel 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.4
Specifies the channel number code, k1 bits 5 to 8. * null(0) - null channel Code 0 is used with the Lockout of Protection request. * working(1..14) - Working channels Codes 1 through n apply in a 1:n architecture Only code 1 applies in a 1+1 architecture *extraTraffic(15) - Extra traffic channel May exist only when provisioned in a 1:n architecture NOTE: Refer to GR-253-CORE for more details
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER null(0), working1(1), working2(2), working3(3), working4(4), working5(5), working6(6), working7(7), working8(8), working9(9), working10(10), working11(11), working12(12), working13(13), working14(14), extraTraffic(15)  

foreSonetLineDiagnosticsK1request 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.5
Defines the various values for K1 byte (1-4) for the type of request For 1+1 systems, Forced and Manual switch request apply. SD and SF requests apply to conditions detected on the protection line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lockout(15), forcedsw(14), sfhp(13), sflp(12), sdhp(11), sdlp(10), manualsw(8), wtr(6), exercise(4), rr(2), donotrevert(1), noreq(0)  

foreSonetLineDiagnosticsK2channel 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.6
Specifies the channel number code, k2 bits 1 to 4 * null - null channel Code 0 is used with the Lockout of Protection request. * working(1..14) - Working channels Codes 1 through n apply in a 1:n architecture Only code1 applies in a 1+1 architecture * extraTraffic(15) - Extra traffic channel May exist only when provisioned in a 1:n architecture NOTE: Refer to GR-253-CORE for more details
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER null(0), working1(1), working2(2), working3(3), working4(4), working5(5), working6(6), working7(7), working8(8), working9(9), working10(10), working11(11), working12(12), working13(13), working14(14), extraTraffic(15)  

foreSonetLineDiagnosticsK2Architecture 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.7
Bit 5 of the K2 byte shall be set to indicate: * Code '0' if the provisioned (or only supported) architecture is 1+1 * Code '1' if the provisioned (or only supported) architecture is 1:n
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER oneplusone(0), onen(1)  

foreSonetLineDiagnosticsK2Mode 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.8
Bits 6 through 8 of the K2 byte shall be set to indicate: * Code '101' if the provisioned mode is bidirectional * Code '100' if the provisioned mode is unidirectional The codes '011', '010', '001' and '000' in K2 bites 6-8 are reserved for future use in 1:n drop and insert(nested) protection switching, and the code '111' is used in detecting an incoming AIS_L.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unidirectional(4), bidirectional(5)  

foreSonetLineDiagnosticsLRDI 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.9
Controls the insertion of line Remote Defect Indication (Line RDI). Line RDI is inserted by transmitting the code 110 (binary) in bit positions 6, 7 and 8 of the K2 byte contained in the transmit stream. off When set to off, Line RDI is NOT inserted in the transmit stream even if LOS/LOF is received on When set to on, Line RDI is inserted continuously in the transmit stream. auto When set to auto, Line RDI is inserted as under normal operation
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), auto(4)  

foreSonetLineDiagnosticsLREI 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.10
Controls the insertion of Line Remote Error Indication (REI_L). The number of BIP errors (B2) detected are encoded in the transmit REI_L (M0/M1) byte. REI_L was previously called Line FEBE (Far End Block Error). off When set to off, insert 0 for M0/M1 bytes, irrespective of the number of B2 errors received. on When set to on, insert 8/8N for M0/M1 bytes continuously. auto When set to auto, resume normal operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), auto(4)  

foreSonetPathConfigTable 1.3.6.1.4.1.326.2.2.1.1.14.4.1
A table of configuration options and statistics that extend the standard SONET Path Tables
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetPathConfigEntry

foreSonetPathConfigEntry 1.3.6.1.4.1.326.2.2.1.1.14.4.1.1
A table entry containing Fore specific extensions to the standard SONET path tables
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetPathConfigEntry  

foreSonetPathRxSignalLabel 1.3.6.1.4.1.326.2.2.1.1.14.4.1.1.2
This variable contains the path signal label byte (C2). The value in this variable is updated to a new path signal label value if the same new value is observed for two consecutive frames.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetPathTxSignalLabel 1.3.6.1.4.1.326.2.2.1.1.14.4.1.1.3
This variable controls the transmit path payload. The default value for ATM is 0x13 (19 decimal). Changing the value of this variable attempts to change the payload and if successfull will change the transmitted C2 label to reflect the new payload. Use the C2 variable in the diagnostics table if you wish to change the C2 value for diagnostic purposes without actually changing the transmitted payload type.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

foreSonetPathLoopbackMode 1.3.6.1.4.1.326.2.2.1.1.14.4.1.1.5
This variable represents the current loopback status of the SONET interface. The possible values are: sonetPathNoLoop (1) means that the interface is not in a loopback state. sonetPathLineLoop (2) means that the receive data is connected to the transmit data. sonetPathDiagLoop (3) means that the transmit data stream is looped back to the receiver. sonetPathOtherLoop (4) means that the interface is in a loopback that is not defined here.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sonetPathNoLoop(1), sonetPathLineLoop(2), sonetPathDiagLoop(3), sonetPathOtherLoop(4)  

foreSonetPathTotalTable 1.3.6.1.4.1.326.2.2.1.1.14.4.2
A table of configuration options and statistics that extend the standard SONET Path Tables
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetPathTotalEntry

foreSonetPathTotalEntry 1.3.6.1.4.1.326.2.2.1.1.14.4.2.1
A table entry containing Fore specific extensions to the standard SONET path tables
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetPathTotalEntry  

foreSonetPathTotalBIPs 1.3.6.1.4.1.326.2.2.1.1.14.4.2.1.1
The number of Path BIP-8 (Bit Interleaved Parity) errors that have been detected since the last time the port has been reset. A path BIP-8 error is detected by comparing the path BIP-8 byte (B3) extracted from the current frame, to the path BIP-8 computed for the previous frame.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetPathTotalLOPs 1.3.6.1.4.1.326.2.2.1.1.14.4.2.1.2
The number of seconds in which path Loss Of Pointer (LOP) has occurred. A path LOP is detected when a 'normal pointer value' is not found in eight consecutive frames. The LOP is cleared when a 'normal pointer value' is detected for three consecutive frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetPathTotalAISs 1.3.6.1.4.1.326.2.2.1.1.14.4.2.1.3
The number of seconds in which path Alarm Indication Signal (AIS) has occurred. A path AIS is asserted when an all-ones pattern is detected in the pointer bytes (H1 and H2) for three consecutive frames. It is cleared when a valid pointer is detected for three consecutive frames. AIS indicates that an upstream failure has been detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetPathTotalRDIs 1.3.6.1.4.1.326.2.2.1.1.14.4.2.1.4
The number of seconds in which path RDI alarm has occurred. A path RDI alarm is detected by extracting bit 5 of the path status byte. If bit 5 is high for ten consecutive frames, a RDI alarm is declared. A RDI alarm is cleared when bit 5 is low for ten consecutive frames. RDI signals are used to alert upstream terminals of a downstream failure in order to initiate trunk conditioning on the failure circuit.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetPathTotalUNEQs 1.3.6.1.4.1.326.2.2.1.1.14.4.2.1.5
The number of seconds in which a path UNEQ defect has occurred. A path UNEQ defect is detected when the STS Signal label (C2 byte) == 0x00
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetPathTotalPLMs 1.3.6.1.4.1.326.2.2.1.1.14.4.2.1.6
The number of seconds in which a path PLM defect has occrred. A path PLM defect is detected when the STS Signal lable (C2 bytes) != 0x00, 0x01, 0x13, 0xFC or 0xFF.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetPathTotalFEBEs 1.3.6.1.4.1.326.2.2.1.1.14.4.2.1.7
The number of path Far End Block Errors (FEBE) that have been detected since the last time the port has been reset. FEBEs are detected by extracting the 4-bit FEBE field from the path status byte (G1). The legal range for the 4 bit field is between 0000 and 1000, representing zero to eight errors. Any other value is interpreted as zero errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetPathCurrentTable 1.3.6.1.4.1.326.2.2.1.1.14.4.3
A table of configuration options and statistics that extend the standard SONET Path table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetPathCurrentEntry

foreSonetPathCurrentEntry 1.3.6.1.4.1.326.2.2.1.1.14.4.3.1
A table entry containing fore specific extensions to the current status table for SONET paths.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetPathCurrentEntry  

foreSonetPathCurrentStatus 1.3.6.1.4.1.326.2.2.1.1.14.4.3.1.1
This variable indicates information about the current status of the sonet path. This variable is encoded as a bit vector so it can represent multiple conditions simultaneously. The various bit positions are: 1 pathPDI-P detected pathPDI-P is set when the incoming path C2 byte is set to a value in the range 0xe1..0xfc.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetPathCurrentBBEs 1.3.6.1.4.1.326.2.2.1.1.14.4.3.1.2
The counter associated with the number of Background Errors encountered by a SONET/SDH Path in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreSonetPathDiagnosticsTable 1.3.6.1.4.1.326.2.2.1.1.14.4.4
A table of diagnostics tests that extend the standard SONET Path Tables
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetPathDiagnosticsEntry

foreSonetPathDiagnosticsEntry 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1
A table entry containing Fore specific extensions to the standard SONET path tables
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetPathDiagnosticsEntry  

foreSonetPathDiagnosticsC2 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.1
Controls the insertion of Signal label/Payload Defect Indication (PDI_P) into the C2 byte of the Sonet path overhead. The various values for Signal label/PDI_P are defined in GR-253-CORE. off When set to off, the C2 byte is set to previously configured C2 value. on When set to on, the foreSonetPathDiagnosticsC2Value is inserted in the C2 byte of the tranmsit stream.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

foreSonetPathDiagnosticsC2Value 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.2
Contains C2 byte value of the transmit stream
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unequipped(0), equippednonspecPL(1), vtstructSTSSPE(2), lockedVTmode(3), asyncDS3mapping(4), asyncDS4na(18), atmmapping(19), dqdbmapping(20), asyncfddimapping(21), hdlcwithscrambling(22), sts1with1vtxPD(225), sts1with2vtxPD(226), sts1with3vtxPD(227), sts1with4vtxPD(228), sts1with5vtxPD(229), sts1with6vtxPD(230), sts1with7vtxPD(231), sts1with8vtxPD(232), sts1with9vtxPD(233), sts1with10vtxPD(234), sts1with11vtxPD(235), sts1with12vtxPD(236), sts1with13vtxPD(237), sts1with14vtxPD(238), sts1with15vtxPD(239), sts1with16vtxPD(240), sts1with17vtxPD(241), sts1with18vtxPD(242), sts1with19vtxPD(243), sts1with20vtxPD(244), sts1with21vtxPD(245), sts1with22vtxPD(246), sts1with23vtxPD(247), sts1with24vtxPD(248), sts1with25vtxPD(249), sts1with26vtxPD(250), sts1with27vtxPD(251), payloaddefect(252)  

foreSonetPathDiagnosticsB3 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.3
Controls the insertion of Path BIP errors in the sonet path B3 byte overhead. off When set to off, do not generate path BIP errors. on When set to on, generate path BIP errors. momentary When set to momentary, transmit a chip dependent number of Sonet frames with path BIP errors.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), momentary(3)  

foreSonetPathDiagnosticsPREI 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.4
Controls the insertion of Sonet Path Remote Error Indication (REI_P) (previously called Far End Block Error (FEBE)). G1 byte 1 2 3 4 5 6 7 8 ----|----|----|----|----|----|----|----| | REI_P | RDI_P | uu | ---------------------------------------- REI_P Path Remote Error Indication RDI_P Path Remote Defect Indication uu Unused off When set to off, the value 0 is inserted in bits 1:4 of G1 byte. on When set to on, the value 0x8 is inserted in bits 1:4 of G1 byte. auto When set to auto, resume normal operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), auto(4)  

foreSonetPathDiagnosticsPAIS 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.5
Controls the insertion of STS Path Alarm Indication Signal (AIS_P). off When set to off, AIS_P is not generated under any circumstances. on When set to on, AIS_P is generated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

foreSonetPathDiagnosticsPERDI 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.6
Controls the insertion of Enhanced Remote Defect Indication. Bits 5,6, and 7 of G1 byte is used for the inserting ERDI. G1 byte 1 2 3 4 5 6 7 8 ----|----|----|----|----|----|----|----| | REI_P | RDI_P | uu | ---------------------------------------- REI_P Path Remote Error Indication RDI_P Path Remote Defect Indication uu Unused on When set to on, foreSonetPathDiagnosticsERDIValue is inserted in the bits 5,6,7 of G1 byte. auto When set to auto, resume normal operation using single bit RDI.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), auto(4)  

foreSonetPathDiagnosticsERDIValue 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.7
Defines the values that may be inserted in the bits 5,6 and 7 of G1 byte. 1xx - One bit RDI 000 - No RDI_P defect with no priority 001 - No RDI_P defect 010 - ERDI_P payload defect 101 - ERDI_P server defect 110 - ERDI_P connectivity defect
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sonetPathERDIOnebitRDI(4), sonetPathERDIserverDefect(5), sonetPathERDIconnDefect(6), sonetPathERDIpayloadDefect(2), sonetPathERDInoDefect(1), sonetPathERDInoPrionoDefect(0)  

foreSonetPathDiagnosticsLOP 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.8
Controls the insertion of Loss of pointer for path level. off When set to off, loss of pointer is not generated. on When set to on, loss of pointer is generated in the transmit direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

foreSonetPathGroupConfigTable 1.3.6.1.4.1.326.2.2.1.1.14.4.5
A table of configuration options for Sonet Path VT Groups that extend the standard SONET Path tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetPathGroupConfigEntry

foreSonetPathGroupConfigEntry 1.3.6.1.4.1.326.2.2.1.1.14.4.5.1
A table entry containing Marconi specific extensions to the SONET Path configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetPathGroupConfigEntry  

foreVTGroup 1.3.6.1.4.1.326.2.2.1.1.14.4.5.1.1
This variable indicates the sonet VT group number within the sonet path. It can range from 0 to 6.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

foreVTWidth 1.3.6.1.4.1.326.2.2.1.1.14.4.5.1.2
This variable indicates the sonet VT width.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER vtWidth15VC11(1), vtWidth2VC12(2), vtWidth3(3), vtWidth6VC2(4), vtWidth6c(5)  

foreSonetVTConfigTable 1.3.6.1.4.1.326.2.2.1.1.14.5.1
A table of sonet VT configuration options that extend the standard sonet VT tables
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetVTConfigEntry

foreSonetVTConfigEntry 1.3.6.1.4.1.326.2.2.1.1.14.5.1.1
A table entry containing Fore specific extensions to the standard sonet VT tables
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetVTConfigEntry  

foreSonetVTLoopbackMode 1.3.6.1.4.1.326.2.2.1.1.14.5.1.1.1
This variable represents the current loopback status of the sonet interface. The possible values are: sonetVTNoLoop(1): interface is not in a loopback state. sonetVTLineLoop(2): data on the receive path is looped back on to the transmit path. sonetVTDiagLoop(3): data to be transmitted on the transmit path is looped back on to the receive path. sonetVTOtherLoop(4): the loopback mode is not defined here.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sonetVTNoLoop(1), sonetVTLineLoop(2), sonetVTDiagLoop(3), sonetVTOtherLoop(4)  

foreSonetVTTotalTable 1.3.6.1.4.1.326.2.2.1.1.14.5.2
A table of statistics that extend the standard sonet VT Tables
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetVTTotalEntry

foreSonetVTTotalEntry 1.3.6.1.4.1.326.2.2.1.1.14.5.2.1
A table entry containing Fore specific extensions to the standard sonet VT tables
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetVTTotalEntry  

foreSonetVTTotalBIPs 1.3.6.1.4.1.326.2.2.1.1.14.5.2.1.1
The number of VT BIP-2 errors that have been detected since the last time this interface has been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetVTTotalREIs 1.3.6.1.4.1.326.2.2.1.1.14.5.2.1.2
The number of REIs that have been detected since the last time this interface has been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetVTTotalLOPs 1.3.6.1.4.1.326.2.2.1.1.14.5.2.1.3
The number of seconds in which VT LOP has occurred since the last time this interface has been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetVTTotalAISs 1.3.6.1.4.1.326.2.2.1.1.14.5.2.1.4
The number of seconds in which VT AIS has occurred since the last time this interface has been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetVTTotalRDIs 1.3.6.1.4.1.326.2.2.1.1.14.5.2.1.5
The number of seconds in which VT RDI has occurred since the last time this interface has been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetVTTotalUNEQs 1.3.6.1.4.1.326.2.2.1.1.14.5.2.1.6
The number of seconds in which VT UNEQ has occurred since the last time this interface has been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetVTTotalPLMs 1.3.6.1.4.1.326.2.2.1.1.14.5.2.1.7
The number of seconds in which VT PLM has occrred since the last time this interface has been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

foreSonetVTDiagnosticsTable 1.3.6.1.4.1.326.2.2.1.1.14.5.3
A table of diagnostic controls that are used to manipulate Sonet virtual tributaries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ForeSonetVTDiagnosticsEntry

foreSonetVTDiagnosticsEntry 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1
A table entry containing Marconi specific extensions to the standard Sonet VT Tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  ForeSonetVTDiagnosticsEntry  

foreSonetVtDiagnosticsBIP 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.1
Controls the insertion of VT BIP errors in the sonet VT V5 byte overhead. on: Generate sonet VT BIP errors continuously. off: Do not generate sonet VT BIP errors. momentary: Generate a chip dependent number of sonet frames with sonet VT BIP errors.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), momentary(3)  

foreSonetVtDiagnosticsRDI 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.2
Controls the generation of VT RDI defects on the selected interface. Value Description on(1) RDI is continually tramsmitted off(2) RDI is never transmitted momentary(3) RDI is transmitted for a short period of time. auto(4) RDI is generated according to the sonet specification
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), momentary(3), auto(4)  

foreSonetVtDiagnosticsRFI 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.3
Controls the generation of VT RFI defects on the selected interface. Value Description on(1) RFI is continually tramsmitted off(2) RFI is never transmitted momentary(3) RFI is transmitted for a short period of time. auto(4) RFI is generated according to the sonet specification
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), momentary(3), auto(4)  

foreSonetVtDiagnosticsAIS 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.4
Controls the generation of VT AIS on the selected interface. Value Description on(1) AIS is continually tramsmitted off(2) AIS is never transmitted momentary(3) AIS is transmitted for a short period of time. auto(4) AIS is generated according to the sonet specification
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), momentary(3), auto(4)  

foreSonetVtDiagnosticsLOP 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.5
Controls the generation of VT LOP on the selected interface. Value Description on(1) LOP is continually tramsmitted off(2) LOP is never transmitted momentary(3) LOP is transmitted for a short period of time.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), momentary(3)  

foreSonetVtDiagnosticsLabel 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.6
Controls the transmission of generated label values to force PLM-V failures on the remote system. Value Description on(1) Use label value in foreSonetVtDiagnosticsLableValue off(2) Transmit label appropriate for VT type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

foreSonetVtDiagnosticsLabelValue 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.7
Selects the label value to be transmitted in order to force PLM-V failures on the remote system.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unequipped(0), equippednonspec(1), asynchronous(2), bitsynchronous(3), bytesynchronous(4)  

foreSonetVtDiagnosticsREI 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.8
Controls the generation of VT REI on the selected interface. REI indicates to the far end that a BIP-2 error check failed. Value Description on(1) REI is continually tramsmitted off(2) REI is never transmitted auto(4) REI is transmitted according to the BIP-2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), auto(4)  

foreSonetLOSDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.1
This trap indicates that the specified SONET port is experiencing Loss Of Signal. Bellcore Document TA-NWT-000253 Section 6.3.1.1.1 states that... A SONET NE shall declare a LOS failure when the LOS defect persists for 2.5 (+- .5) seconds, or when a LOS defect is present and the criteria for LOF failure declaration have been met.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetLOSCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.2
This trap indicates that the LOS condition identified by trap foreSonetLOSDetected has been cleared.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathLabelDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.3
This trap indicates that the specified SONET port is receiving and errored C2 Path Label byte. Reference Bellcore Document TA-NWT-000253 Section 3.3.2.3 and 6.3.1.1.8 the Path Label (C2) byte should have the value 0x13 or 0x01.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathLabelCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.4
This trap indicates that the Errored Path Label (C2) byte error condition signaled by the foreSonetPathLabelDetected trap has been cleared.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetLineAISDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.5
This trap indicates that the specified SONET port is receiving a Line level Alarm Indication Signal from the far-end equipment.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetLineAISCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.6
This trap indicates that the Line AIS error condition signaled by the foreSonetLineAISDetected trap has been cleared.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetLOFDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.7
This trap indicates that the specified SONET port is experiencing Loss Of Frame (LOF) failure. An LOF failure is declared when the LOF defect persists fore a period of 2.5 +/- 0.5 seconds, except when an LOS defect or failure is present.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetLOFCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.8
This trap indicates that the LOF failure identified by trap foreSonetLOFDetected has been cleared. The LOF failure is cleared when the LOS failure is declared, or when the LOF defect is absent for 10 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetLineRDIDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.9
This trap indicates that the specified SONET port is experiencing Line Remote Defect Indication (LRDI). A Line RDI failure is declared when the incoming Line RDI defects lasts for 2.5 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetLineRDICleared 1.3.6.1.4.1.326.2.2.1.1.14.0.10
This trap indicates that the Line RDI failure identified by trap foreSonetLineRDIDetected has been cleared. The Line RDI failure is cleared when no Line RDI defects are detected for 10 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathAISDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.11
This trap indicates that the specified SONET port is experiencing Path Alarm Inidication Signal (PAIS). A Path AIS failure is declared when the Path AIS defect persists for 2.5 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathAISCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.12
This trap indicates that the PathAIS failure identified by trap foreSonetPathAISDetected has been cleared. A PAIS failure is cleared when the PAIS defect is absent for 10 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathLOPDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.13
This trap indicates that the specified SONET port is experiencing Loss Of Pointer (LOP). A LOP failure is declared when the LOP defect persists for a period of 2.5 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathLOPCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.14
This trap indicates that the LOP failure identified by trap foreSonetLOPDetected has been cleared. A LOP failure is cleared when the LOP defect is absent for 10 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathUNEQDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.15
This trap indicates that the specified SONET port is experiencing unequiped (UNEQ). A UNEQ failure is declared when the UNEQ defect persists for a period of 2.5 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathUNEQCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.16
This trap indicates that the UNEQ failure identified by trap foreSonetUNEQDetected has been cleared. A UNEQ failure is cleared when the UNEQ defect is absent for 10 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathRDIDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.17
This trap indicates that the specified SONET port is experiencing Path Remote Defect Indication (PRDI). A Path RDI failure is declared when the incoming Path RDI defects lasts for 2.5 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathRDICleared 1.3.6.1.4.1.326.2.2.1.1.14.0.18
This trap indicates that the Path RDI failure identified by trap foreSonetPathRDIDetected has been cleared. The Path RDI failure is cleared when no Path RDI defects are detected for 10 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathPDIDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.19
This trap indicates that the specified SONET path is experiencing a PDI-P ( Path Defect Indication) condition. A PDI-P indication is signalled by a value in the C2 ( path label ) byte in the range 0xe0..0xfc.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetPathPDICleared 1.3.6.1.4.1.326.2.2.1.1.14.0.20
This trap indicates that the PDI falure identified by trap foreSonetPathPDIDetected has been cleared.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetLineBIPDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.21
This trap indicates that the specified SONET port is experiencing Bit Interleaved Parity (BIP) errors. A Line BIP failure is declared when the Line BIP defect persists for a period of 2.5 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetLineBIPCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.22
This trap indicates that the Line BIP failure identified by trap asxSonetAtmLineBIPDetected has been cleared. A Line BIP failure is cleared when the Line BIP defect is absent for 10 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtAISDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.23
This trap indicates that the specified Sonet virtual tributary is receiving an AIS indication from the far end. An AIS-V failure is declared when the AIS-V defect persists for 2.5 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtAISCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.24
This trap indicates that the virtual tributary AIS failure condition has been cleared. An AIS-V failure is cleared when the AIS-V defect is absent for 10 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtLOPDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.25
This trap indicates that the specified virtual tributary is receiving an LOP-V failure. An LOP-V failure is declared when an LOP-V defect persists for 2.5 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtLOPCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.26
This trap indicates that the specified virtual tributary is no longer experiencing loss-of-pointer failure. An LOP-V failure is cleared when the LOP-V defect is absent for 10 +/- 0.5 seconds
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtUNEQDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.27
This trap indicates that the specified virtual tributary is receiving an UNEQ virtual tributary. (V5 byte is 0 ).
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtUNEQCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.28
This trap indicates that the specified virtual tributary is no longer receving an UNEQ virtual tributary.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtVILMDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.29
This trap indicates that the specified virtual tributary is experiencing a VT path label mismatch failure, PLM-V.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtVILMCleared 1.3.6.1.4.1.326.2.2.1.1.14.0.30
This trap indicates that the specified virtual tributary is no longer experiencing a PLM-V failure.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtRDIDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.31
This trap indicates that the specified virtual tributary is experiencing an RDI failure. An RDI-V failure is declared after the interface receives RDI-V defects for 2.5 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtRDICleared 1.3.6.1.4.1.326.2.2.1.1.14.0.32
This trap indicates that the specified virtual tributary is no longer experiencing an RDI failure. An RDI-V failure is cleared after the interface receives no RDI-V defects for 10 +/- 0.5 seconds.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtRFIDetected 1.3.6.1.4.1.326.2.2.1.1.14.0.33
This trap indicates that the specified virtual tributary is experiencing an RFI-V failure. An RFI-V failure is declared within 5 milliseconds of the detection of an incoming RFI-V indication.
Status: current Access: read-write
NOTIFICATION-TYPE    

foreSonetVtRFICleared 1.3.6.1.4.1.326.2.2.1.1.14.0.34
This trap indicates that the specified virtual tributary is no longer experiencing an RFI-V failure. An RFI-V failure is cleared within 50 milliseconds of the removal of an incoming RFI-V indication.
Status: current Access: read-write
NOTIFICATION-TYPE