Fore-Apsgroup-MIB

File: Fore-Apsgroup-MIB.mib (11683 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC Fore-Common-MIB
Fore-TrapLog-MIB Fore-Switch-MIB

Imported symbols

Integer32 OBJECT-TYPE NOTIFICATION-TYPE
MODULE-IDENTITY DisplayString atmSwitch
asx trapLogIndex hwPortName
hwPortBoard hwPortModule hwPortNumber

Defined Types

ApsPortEntry  
SEQUENCE    
  apsBoard Integer32
  apsModule Integer32
  apsPort Integer32
  apsAdminMode INTEGER
  apsOperMode INTEGER
  apsPortGroupName DisplayString

ApsGroupEntry  
SEQUENCE    
  apsGroupName DisplayString
  apsGroupStateCommand INTEGER
  apsGroupLastCommand INTEGER
  apsWorkingLineState INTEGER
  apsProtectionLineState INTEGER
  apsGroupMode INTEGER
  apsRxK1K2 INTEGER
  apsRxChannel INTEGER
  apsTxK1K2 INTEGER
  apsTxChannel INTEGER
  apsRevertMode INTEGER
  apsRevertTimer Integer32

Defined Values

foreAps 1.3.6.1.4.1.326.2.2.1.1.16
SONET APS
MODULE-IDENTITY    

apsPortGroup 1.3.6.1.4.1.326.2.2.1.1.16.1
OBJECT IDENTIFIER    

apsGroup 1.3.6.1.4.1.326.2.2.1.1.16.2
OBJECT IDENTIFIER    

apsPortTable 1.3.6.1.4.1.326.2.2.1.1.16.1.1
A table of SONET APS port configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ApsPortEntry

apsPortEntry 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1
A table entry containing SONET APS configuration information for each APS port.
Status: current Access: not-accessible
OBJECT-TYPE    
  ApsPortEntry  

apsBoard 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.1
The index of this port's switch board.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

apsModule 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.2
The network module of this port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

apsPort 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.3
The number of this port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

apsAdminMode 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.4
This variable indicates the APS configuration for this port. Unprotected indicates that APS is not configured for this port. Working indicates that this port is a working channel. Protection indicates that this port is a protection channel.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER working(1), protection(2), unprotected(3)  

apsOperMode 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.5
This variable indicates if this port is an active or standby APS channel. If APS is not configured for this port, the mode is notApplicable. loopbackOn indicates that the port is configured in the loopback mode and is the port on which the loopback has been enabled(or is under test). loopbackOff indicates that the port is configured in the loopback mode and is the port which is in the disabled state (not under test).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), standby(2), notApplicable(3), loopbackOn(4), loopbackOff(5)  

apsPortGroupName 1.3.6.1.4.1.326.2.2.1.1.16.1.1.1.6
This object identifies the APS group this port is associated with.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

apsGroupTable 1.3.6.1.4.1.326.2.2.1.1.16.2.1
A table of SONET APS port group configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ApsGroupEntry

apsGroupEntry 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1
A table entry containing SONET APS configuration information for each APS group.
Status: current Access: not-accessible
OBJECT-TYPE    
  ApsGroupEntry  

apsGroupName 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.1
This object identifies the APS group. of all the ports associated with this group.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

apsGroupStateCommand 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.2
A user initiated APS command. Note this object is write-only and reading it will result in implementation-specific results.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), lockout(2), forceSwitchToWorking(3), forceSwitchToProtection(4), manualSwitchToWorking(5), manualSwitchToProtection(6)  

apsGroupLastCommand 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.3
Last Aps Command issued by the user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER clear(1), lockout(2), forceSwitchToWorking(3), forceSwitchToProtection(4), manualSwitchToWorking(5), manualSwitchToProtection(6), suspendWorking(7), suspendProtection(8), noRequest(9)  

apsWorkingLineState 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.4
Line State of the Working Port of the APS Group.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER signalFailure(1), signalDegrade(2), none(3), notAvailable(4)  

apsProtectionLineState 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.5
Line State of the Protection Port of the APS Group.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER signalFailure(1), signalDegrade(2), none(3), notAvailable(4)  

apsGroupMode 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.6
This variable indicates the APS switching mode for this APS group.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER uni-directional(1), bi-directional(2)  

apsRxK1K2 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.7
Command specified in the received K1K2 bytes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER lockout(1), forceSwitch(2), manualSwitch(3), signalFailure(4), signalDegrade(5), exercise(6), waitToRestore(7), reverseRequest(8), doNotRevert(9), noRequest(10), none(11), notAvailable(12)  

apsRxChannel 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.8
Channel specified in received K1K2 bytes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER working(1), protection(2), not-applicable(3)  

apsTxK1K2 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.9
Command specified in the transmitted K1K2 bytes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER lockout(1), forceSwitch(2), manualSwitch(3), signalFailure(4), signalDegrade(5), exercise(6), waitToRestore(7), reverseRequest(8), doNotRevert(9), noRequest(10), none(11), notAvailable(12)  

apsTxChannel 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.10
Channel specified in transmitted K1K2 bytes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER working(1), protection(2), not-applicable(3)  

apsRevertMode 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.11
APS revertive mode configuration
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

apsRevertTimer 1.3.6.1.4.1.326.2.2.1.1.16.2.1.1.12
APS revertive timer value in minutes
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

apsSwitchOver 1.3.6.1.4.1.326.2.2.0.2017
This trap alerts that an aps switchover has occurred and the active port is identified by the tuple {hwPortBoard, hwPortModule, hwPortNumber}.
Status: current Access: read-write
NOTIFICATION-TYPE