FSC-SERVERCONTROL2-MIB

File: FSC-SERVERCONTROL2-MIB.mib (245835 bytes)

Imported modules

RFC-1212 RFC1213-MIB RFC1155-SMI

Imported symbols

OBJECT-TYPE mib-2 DisplayString
Counter Gauge IpAddress

Defined Types

PhysAddress  
OCTET STRING    

TrueFalse  
INTEGER false(1), true(2)    

TrueFalseUnknown  
INTEGER unknown(1), false(2), true(3)    

UnitClass  
INTEGER unknown(1), standardServer(2), storageExtension(3), bladeServerChassis(4), bladeServer(5), clusterNode(6), multiNodeChassis(7), multiNodeServer(8), virtualServer(9), virtualPartition(10), systemboardInPartition(11), virtualServerVmware(20), virtualServerHyperV(21), virtualServerXen(22), virtualServerPan(23)    

CompStatus  
INTEGER ok(1), warning(2), error(3), unknown(5), notPresent(6), notManageable(7)    

LogSeverity  
INTEGER informational(1), minor(2), major(3), critical(4)    

OsLogSeverity  
INTEGER ok(1), warning(2), error(3)    

Sc2Units  
SEQUENCE    
  sc2uUnitId INTEGER
  sc2UnitClass UnitClass
  sc2UnitCabinetNr INTEGER
  sc2UnitDesignation DisplayString
  sc2UnitModelName DisplayString
  sc2UnitManufacturer DisplayString
  sc2UnitSerialNumber DisplayString
  sc2UnitLocation DisplayString
  sc2UnitContact DisplayString
  sc2UnitAdminURL DisplayString
  sc2FrontDoorStatus INTEGER
  sc2HousingOpenStatus INTEGER
  sc2MsgLogLanguages DisplayString
  sc2UnitWorldWideName DisplayString
  sc2RemcsId DisplayString
  sc2AssetTag DisplayString
  sc2MsgLogAvailable TrueFalse
  sc2ManagementIpAddress DisplayString
  sc2HasUefiFirmware TrueFalse
  sc2ManagementIpAddressV6 DisplayString

Sc2UnitParents  
SEQUENCE    
  sc2pUnitId INTEGER
  sc2ParentUnit INTEGER
  sc2ParentUnitClass UnitClass

Sc2UnitChilds  
SEQUENCE    
  sc2cUnitId INTEGER
  sc2cChildNr INTEGER
  sc2ChildUnit INTEGER
  sc2ChildUnitClass UnitClass

Sc2ManagementNodes  
SEQUENCE    
  sc2mnUnitId INTEGER
  sc2mnNodeNr INTEGER
  sc2UnitNodeIfType INTEGER
  sc2UnitNodeAddress DisplayString
  sc2UnitNodeIpNetmask DisplayString
  sc2UnitNodeGateway DisplayString
  sc2UnitNodeName DisplayString
  sc2UnitNodeClass INTEGER
  sc2UnitNodeMacAddress PhysAddress
  sc2UnitNodeUseDHCP INTEGER
  sc2UnitNodeControllerType DisplayString
  sc2UnitNodeControllerModel DisplayString
  sc2UnitNodeControllerFWVersion DisplayString
  sc2UnitNodeControllerStorage INTEGER
  sc2UnitNodeSNMPEnabled TrueFalseUnknown
  sc2UnitNodeCIMEnabled TrueFalseUnknown
  sc2UnitNodeRemoteIPMIEnabled TrueFalseUnknown

Sc2ManagementProcessors  
SEQUENCE    
  sc2spUnitId INTEGER
  sc2spProcessorNr INTEGER
  sc2spModelName DisplayString
  sc2spFirmwareVersion DisplayString
  sc2spBatteryStatus INTEGER
  sc2spBatteryDischargeTime INTEGER
  sc2spTimeOnBattery Counter
  sc2spDoBatteryChargeCycle INTEGER
  sc2spBatteryChargeLevel Gauge

Sc2ManagedUpsNodes  
SEQUENCE    
  sc2upsUnitId INTEGER
  sc2upsNr INTEGER
  sc2upsVendorName DisplayString
  sc2upsModelName DisplayString
  sc2upsMgmtAddress DisplayString
  sc2upsMibRoot DisplayString
  sc2upsSnmpCommunity DisplayString

Sc2Servers  
SEQUENCE    
  sc2srvUnitId INTEGER
  sc2srvPhysicalMemory INTEGER
  sc2srvLastBootResult INTEGER
  sc2srvCurrentBootStatus INTEGER
  sc2srvShutdownCommand INTEGER
  sc2srvShutdownDelay INTEGER
  sc2srvUUID DisplayString
  sc2srvPhysicalMemoryOs INTEGER
  sc2srvUUIDWireFormat DisplayString
  sc2srvOsPlatform INTEGER
  sc2srvBiosVersion DisplayString
  sc2srvHasEncryptedPartitions TrueFalseUnknown
  sc2srvTrustedExecutionTechnologyEnabled TrueFalseUnknown

Sc2UnitPowerOnOff  
SEQUENCE    
  sc2ooUnitId INTEGER
  sc2PowerOnOffStatus INTEGER
  sc2LastPowerOffSource INTEGER
  sc2LastPowerOnSource INTEGER
  sc2LastPowerOnTime INTEGER
  sc2PowerOnCounts INTEGER
  sc2PowerOnDuration INTEGER
  sc2PowerOffDuration INTEGER
  sc2PowerFailRecovery INTEGER
  sc2PowerCommand INTEGER
  sc2PowerSupplyRedundancy TrueFalseUnknown
  sc2PowerSupplyMatchStatus INTEGER

Sc2Performance  
SEQUENCE    
  sc2perfUnitId INTEGER
  sc2perfNr INTEGER
  sc2PerformanceType INTEGER
  sc2PerformanceObjectNr INTEGER
  sc2PerformanceName DisplayString
  sc2PerformanceValue Gauge

Sc2TimerOnOff  
SEQUENCE    
  sc2tooUnitId INTEGER
  sc2tooDayOfWeek INTEGER
  sc2OnTime INTEGER
  sc2OffTime INTEGER

Sc2PowerMonitoring  
SEQUENCE    
  sc2pmUnitId INTEGER
  sc2pmCurrentPowerMonitoringAvailable TrueFalse
  sc2pmCurrentPowerMonitoringEnabled TrueFalse
  sc2pmNominalPowerConsumption INTEGER
  sc2pmCurrentPowerConsumption Gauge
  sc2pmCurrentPowerControl INTEGER
  sc2pmPowerLimitStatus INTEGER
  sc2pmPowerLimitThreshold INTEGER
  sc2pmPowerLimitWarning INTEGER
  sc2pmRedundancyCritLevel INTEGER
  sc2pmPowerControlMode INTEGER
  sc2pmPowerDisplayUnit INTEGER

Sc2UtilizationHistory  
SEQUENCE    
  sc2uthUnitId INTEGER
  sc2uthEntity INTEGER
  sc2uthTimeStamp INTEGER
  sc2uthHardwareUUID DisplayString
  sc2uthAverageValue Gauge
  sc2uthMinValue Gauge
  sc2uthMaxValue Gauge

Sc2PowerSourceInformation  
SEQUENCE    
  sc2psiUnitId INTEGER
  sc2psiPowerSourceType DisplayString
  sc2psiPowerSourcePhase INTEGER
  sc2psiPowerSourceVoltage INTEGER

Sc2VirtualIoManager  
SEQUENCE    
  sc2viomUnitId INTEGER
  sc2viomCurrentManagerId DisplayString
  sc2viomEnabled TrueFalseUnknown
  sc2viomBiosSupport TrueFalseUnknown
  sc2viomConnectionStatus INTEGER

Sc2PowerSupplyRedundancyConfiguration  
SEQUENCE    
  sc2PSRedUnitId INTEGER
  sc2PSRedundancyMode INTEGER
  sc2PSRedundancyModeConfig INTEGER
  sc2PSRedundancyRequiredPowerSupplies INTEGER
  sc2PSRedundancyPopulatedPowerSupplies INTEGER
  sc2PSRedundancyConfigurationStatus CompStatus
  sc2PSRedundancyThresholdStatus CompStatus
  sc2PSRedundancyStatus INTEGER

Sc2PerformanceValues  
SEQUENCE    
  sc2PerfValUnitId INTEGER
  sc2PerfValType INTEGER
  sc2PerfValObjectNr INTEGER
  sc2PerfValName DisplayString
  sc2PerfValCurrentValue Gauge

Sc2TemperatureSensors  
SEQUENCE    
  sc2tempUnitId INTEGER
  sc2tempSensorNr INTEGER
  sc2tempSensorDesignation DisplayString
  sc2tempSensorIdentifier DisplayString
  sc2tempSensorStatus INTEGER
  sc2tempCurrentTemperature Gauge
  sc2tempWarningLevel INTEGER
  sc2tempCriticalLevel INTEGER
  sc2tempCriticalReaction INTEGER

Sc2Fans  
SEQUENCE    
  sc2fanUnitId INTEGER
  sc2fanNr INTEGER
  sc2fanDesignation DisplayString
  sc2fanIdentifier DisplayString
  sc2fanStatus INTEGER
  sc2fanCurrentSpeed Gauge
  sc2fanQuality Gauge
  sc2fanFailReaction INTEGER
  sc2fanFailShutdownDelay INTEGER
  sc2fanCoolingDeviceType INTEGER

Sc2Airflow  
SEQUENCE    
  sc2afUnitId INTEGER
  sc2afExhaustAirflowVolume INTEGER
  sc2afExhaustAirflowVolumeUnit DisplayString

Sc2SystemBoard  
SEQUENCE    
  sc2sbUnitId INTEGER
  sc2sbBoardNr INTEGER
  sc2SystemBoardModelName DisplayString
  sc2SystemBoardProductNumber DisplayString
  sc2SystemBoardRevision DisplayString
  sc2SystemBoardSerialNumber DisplayString
  sc2SystemBoardDesignation DisplayString
  sc2SystemBoardSDCardSlotPresent TrueFalseUnknown

Sc2PowerSupply  
SEQUENCE    
  sc2psUnitId INTEGER
  sc2psPowerSupplyNr INTEGER
  sc2PowerSupplyDesignation DisplayString
  sc2PowerSupplyIdentifier DisplayString
  sc2PowerSupplyStatus INTEGER
  sc2psPowerSupplyLoad INTEGER
  sc2psPowerSupplyNominal INTEGER

Sc2Voltages  
SEQUENCE    
  sc2voUnitId INTEGER
  sc2voSensorNr INTEGER
  sc2VoltageDesignation DisplayString
  sc2VoltageStatus INTEGER
  sc2VoltageCurrentValue Gauge
  sc2VoltageNominalValue INTEGER
  sc2VoltageMinimumLevel INTEGER
  sc2VoltageMaximumLevel INTEGER
  sc2VoltageCurrentLoad Gauge

Sc2CPUs  
SEQUENCE    
  sc2cpuUnitId INTEGER
  sc2cpuNr INTEGER
  sc2cpuDesignation DisplayString
  sc2cpuStatus INTEGER
  sc2cpuModelName DisplayString
  sc2cpuManufacturer DisplayString
  sc2cpuStep DisplayString
  sc2cpuCurrentSpeed INTEGER
  sc2cpuNumberLogicals INTEGER
  sc2cpuCacheL1Size INTEGER
  sc2cpuCacheL2Size INTEGER
  sc2cpuCacheL3Size INTEGER
  sc2cpuNumberCores INTEGER
  sc2cpuFamily INTEGER
  sc2cpuEnabledCores INTEGER
  sc2cpuMultithreadingEnabled INTEGER
  sc2cpuConfigurationStatus INTEGER
  sc2cpuMCDRAMSize INTEGER
  sc2cpuMCDRAMSpeed INTEGER
  sc2cpuMCDRAMMode INTEGER
  sc2cpuMCDRAMCacheSize INTEGER
  sc2cpuMCDRAMMemoryModel INTEGER

Sc2MemoryModules  
SEQUENCE    
  sc2memUnitId INTEGER
  sc2memModuleNr INTEGER
  sc2memModuleDesignation DisplayString
  sc2memModuleStatus INTEGER
  sc2memModuleBank INTEGER
  sc2memModuleCapacity INTEGER
  sc2memModuleStartAddress INTEGER
  sc2memModuleForm DisplayString
  sc2memModuleType DisplayString
  sc2memModuleCorrErrors Counter
  sc2memModuleUncorrErrors Counter
  sc2memModuleApproved INTEGER
  sc2memModuleConfiguration INTEGER
  sc2memModuleFrequency INTEGER
  sc2memModuleMaxFrequency INTEGER
  sc2memModuleVoltInterface DisplayString

Sc2ComponentPowerConsumption  
SEQUENCE    
  sc2cpcUnitId INTEGER
  sc2cpcComponentClass INTEGER
  sc2cpcComponentIndex INTEGER
  sc2cpcDesignation DisplayString
  sc2cpcCurrentValue INTEGER

Sc2TrustedPlatformModule  
SEQUENCE    
  sc2tpmUnitId INTEGER
  sc2tpmHardwareAvailable TrueFalseUnknown
  sc2tpmBiosEnabled TrueFalseUnknown
  sc2tpmEnabled TrueFalseUnknown
  sc2tpmActivated TrueFalseUnknown
  sc2tpmOwnership TrueFalseUnknown

Sc2PersistentMemoryModules  
SEQUENCE    
  sc2nvmemMemoryModeEnabled TrueFalseUnknown
  sc2nvmemPersistentModeEnabled TrueFalseUnknown
  sc2nvmemPackageSparingCapable TrueFalseUnknown
  sc2nvmemEncryptionEnabled TrueFalseUnknown
  sc2nvmemFirmwareRevision DisplayString
  sc2nvmemTotalSize INTEGER
  sc2nvmemRawCapacity INTEGER
  sc2nvmemVolatileCapacity INTEGER
  sc2nvmemPersistentCapacity INTEGER
  sc2nvmemVolatilePercent INTEGER
  sc2nvmemPersistentPercent INTEGER
  sc2nvmemVolatileStart DisplayString
  sc2nvmemPersistentStart DisplayString
  sc2nvmemHealthStatusNonCritical TrueFalseUnknown
  sc2nvmemHealthStatusCritical TrueFalseUnknown
  sc2nvmemHealthStatusFatal TrueFalseUnknown
  sc2nvmemPowerOnTime INTEGER
  sc2nvmemUpTime INTEGER
  sc2nvmemLiftetimeRemaining INTEGER
  sc2nvmemAveragePowerBudget INTEGER
  sc2nvmemPeakPowerBudget INTEGER

Sc2MessageLogs  
SEQUENCE    
  sc2msgUnitId INTEGER
  sc2msgLogEntryNr INTEGER
  sc2msgLogEntryData OCTET STRING

Sc2Watchdogs  
SEQUENCE    
  sc2wdUnitId INTEGER
  sc2WatchdogType INTEGER
  sc2WatchdogStatus INTEGER
  sc2WatchdogTime INTEGER
  sc2WatchdogAction INTEGER

Sc2RecoverySettings  
SEQUENCE    
  sc2asrUnitId INTEGER
  sc2asrNrRebootRetries INTEGER
  sc2asrDefaultRebootRetries INTEGER
  sc2asrNextBootSource INTEGER
  sc2asrRebootFailAction INTEGER
  sc2asrRestartDelay INTEGER
  sc2asrPostErrorHalt INTEGER

Sc2MessageTextLogs  
SEQUENCE    
  sc2msgTextLogUnitId INTEGER
  sc2msgTextLogLanguage INTEGER
  sc2msgTextLogSeqNr INTEGER
  sc2msgTextLogTimestamp INTEGER
  sc2msgTextLogMessage DisplayString
  sc2msgTextLogErrorCode INTEGER
  sc2msgTextLogSeverity INTEGER
  sc2msgTextLogCSSComponent TrueFalse

Sc2MessageLogActionHints  
SEQUENCE    
  sc2mlaLanguage INTEGER
  sc2mlaErrorCode INTEGER
  sc2mlaType INTEGER
  sc2mlaIndex INTEGER
  sc2mlaMessage DisplayString

Sc2StatusComponents  
SEQUENCE    
  sc2csUnitId INTEGER
  sc2csStatusOverall CompStatus
  sc2csStatusBoot CompStatus
  sc2csStatusPowerSupply CompStatus
  sc2csStatusTemperature CompStatus
  sc2csStatusFans CompStatus
  sc2csStatusVoltages CompStatus
  sc2csStatusCpu CompStatus
  sc2csStatusMemoryModule CompStatus

Sc2ComponentStatusSensors  
SEQUENCE    
  sc2cssUnitId INTEGER
  sc2cssSensorNumber INTEGER
  sc2cssSensorDesignation DisplayString
  sc2cssSensorDevice DisplayString
  sc2cssSensorDeviceInstance INTEGER
  sc2cssSensorPhysicalLed TrueFalse
  sc2cssSensorCssComponent TrueFalse
  sc2cssSensorStatus INTEGER
  sc2cssComponentServicePartId DisplayString

Sc2MaintenanceObjects  
SEQUENCE    
  sc2mtUnitId INTEGER
  sc2ErrorCounterStartTime INTEGER
  sc2SendTestTrap INTEGER
  sc2AddTrapDestination IpAddress

Sc2FirmwareVersions  
SEQUENCE    
  sc2fwUnitId INTEGER
  sc2fwType INTEGER
  sc2fwModelName DisplayString
  sc2fwVersion DisplayString

Sc2DeployInfo  
SEQUENCE    
  sc2dplInfoUnitId INTEGER
  sc2DeployInfoChassisId DisplayString
  sc2DeployInfoMacAddr1 PhysAddress
  sc2DeployInfoMacAddr2 PhysAddress
  sc2DeployInfoMacAddr3 PhysAddress
  sc2DeployInfoMacAddr4 PhysAddress
  sc2DeployInfoIpAddr1 IpAddress
  sc2DeployInfoIpAddr2 IpAddress
  sc2DeployInfoIpAddr3 IpAddress
  sc2DeployInfoIpAddr4 IpAddress
  sc2DeployInfoNetMask1 IpAddress
  sc2DeployInfoNetMask2 IpAddress
  sc2DeployInfoNetMask3 IpAddress
  sc2DeployInfoNetMask4 IpAddress
  sc2DeployInfoGateway1 IpAddress
  sc2DeployInfoGateway2 IpAddress
  sc2DeployInfoGateway3 IpAddress
  sc2DeployInfoGateway4 IpAddress
  sc2DeployInfoHostname DisplayString
  sc2DeployInfoMasterImageReference DisplayString
  sc2DeployInfoStatusOfBlade INTEGER
  sc2DeployInfoLanStatusOfSlot INTEGER
  sc2DeployInfoAutomaticRecovery INTEGER
  sc2DeployInfoStatusOfCloning INTEGER
  sc2DeployInfoBootMode INTEGER

Sc2OemDeployInfo  
SEQUENCE    
  sc2odplInfoUnitId INTEGER
  sc2odplParamId INTEGER
  sc2OemDeployInfoParamData DisplayString

Sc2DeployLanInterfaces  
SEQUENCE    
  sc2dplLanUnitId INTEGER
  sc2dplLanInterfaceNr INTEGER
  sc2dplLanMacAddress PhysAddress

Sc2DriverMonitorComponents  
SEQUENCE    
  sc2drvmonCompClass INTEGER
  sc2drvmonCompIndex INTEGER
  sc2drvmonCompName DisplayString
  sc2drvmonCompType INTEGER
  sc2drvmonCompDriverName DisplayString
  sc2drvmonCompLocationDesignation DisplayString
  sc2drvmonCompLocationKey DisplayString
  sc2drvmonCompStatus CompStatus
  sc2drvmonCompErrorAcknowledge INTEGER

Sc2DriverMonitorMessages  
SEQUENCE    
  sc2drvmonMsgSeqNr INTEGER
  sc2drvmonMsgTimestamp INTEGER
  sc2drvmonMsgMessage DisplayString
  sc2drvmonMsgEventId INTEGER
  sc2drvmonMsgSeverity OsLogSeverity
  sc2drvmonMsgErrorCode INTEGER
  sc2drvmonOrigLogMessage DisplayString
  sc2drvmonOrigLogSource DisplayString
  sc2drvmonOrigLogId INTEGER
  sc2drvmonOrigLogSeverity OsLogSeverity

Defined Values

enterprises 1.3.6.1.4.1
OBJECT IDENTIFIER    

sni 1.3.6.1.4.1.231
OBJECT IDENTIFIER    

sniProductMibs 1.3.6.1.4.1.231.2
OBJECT IDENTIFIER    

sniExtensions 1.3.6.1.4.1.231.2.10
OBJECT IDENTIFIER    

sniServerMgmt 1.3.6.1.4.1.231.2.10.2
OBJECT IDENTIFIER    

sniInventory 1.3.6.1.4.1.231.2.10.2.1
OBJECT IDENTIFIER    

sniCommon 1.3.6.1.4.1.231.2.10.2.2
OBJECT IDENTIFIER    

fscServerControl2 1.3.6.1.4.1.231.2.10.2.2.10
OBJECT IDENTIFIER    

sc2Notifications 1.3.6.1.4.1.231.2.10.2.2.10.20
OBJECT IDENTIFIER    

sc2AgentInfo 1.3.6.1.4.1.231.2.10.2.2.10.1
OBJECT IDENTIFIER    

sc2AgentId 1.3.6.1.4.1.231.2.10.2.2.10.1.1
Agent identification string
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2AgentCompany 1.3.6.1.4.1.231.2.10.2.2.10.1.2
Agent's company name (e.g. Fujitsu Technology Solutions)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2AgentVersion 1.3.6.1.4.1.231.2.10.2.2.10.1.3
Agent's version string (e.g. 1.05)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2AgentBuild 1.3.6.1.4.1.231.2.10.2.2.10.1.4
Compilation time and date of agent program
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2AgentWriteAllowed 1.3.6.1.4.1.231.2.10.2.2.10.1.5
Defines whether writable objects can be written (except shutdown/power-off operations)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), write-not-allowed(2), write-allowed(3)  

sc2AgentShutdownAllowed 1.3.6.1.4.1.231.2.10.2.2.10.1.6
Defines whether shutdown/power-off objects can be written
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), shutdown-not-allowed(2), shutdown-allowed(3)  

sc2UnitInformation 1.3.6.1.4.1.231.2.10.2.2.10.2
OBJECT IDENTIFIER    

sc2LocalServerUnitId 1.3.6.1.4.1.231.2.10.2.2.10.2.1
Unit identifier number of the local server (usually is ID 1). This ID can be used as index into the sc2Units table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2NumberUnits 1.3.6.1.4.1.231.2.10.2.2.10.2.2
Number of available units (size of sc2Units table).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2UnitTable 1.3.6.1.4.1.231.2.10.2.2.10.2.3
Description of all units in this MIB
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2Units

sc2Units 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2Units  

sc2uUnitId 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2UnitClass 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.2
Unit classification (type)
Status: mandatory Access: read-only
OBJECT-TYPE    
  UnitClass  

sc2UnitCabinetNr 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.3
Unit cabinet number (used for addressing storage extension cabinets or server blades). The ID of the local server is usually 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2UnitDesignation 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.4
Unit designation / housing type (e.g. 'H200R')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitModelName 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.5
Unit model name (e.g. 'PRIMERGY RX100')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitManufacturer 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.6
Unit manufacturer name (e.g. 'Fujitsu Technology Solutions')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitSerialNumber 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.7
Unit serial number (e.g. 'YBCL123456')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitLocation 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.8
Unit location string (e.g. 'ServerCenter Room 17, Rack 9')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitContact 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.9
Unit contact name (e.g. 'Mr. Bond')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitAdminURL 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.10
URL of administration HTML interface (e.g. 'http://MyServer/admin')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2FrontDoorStatus 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.11
Status describing whether the front door is open or closed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), open(2), closed(3)  

sc2HousingOpenStatus 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.12
Status describing whether the housing is open or closed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), open(2), closed(3), opened-and-closed(4)  

sc2MsgLogLanguages 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.13
Supported languages of text message log (comma-seperated list of decimal language codes, see sc2MessageTextLogTable). e.g. '1031,1033' means German and English are supported. English (1033) is the default language and is always available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitWorldWideName 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.14
Unit World Wide Name. A 64-bit sized address for storage devices (e.g. '6661E2B0A00B88FB')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2RemcsId 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.15
REMCS system identification string (binary data): Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID for Company Name MM...M : 12byte : Model Name mm...m : 12byte : Device Name CC : 2byte : Checksum nn...n : 12byte : Serial number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2AssetTag 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.16
Customer specific asset tag (40 bytes)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2MsgLogAvailable 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.17
Replies whether a message log is available on this unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

sc2ManagementIpAddress 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.18
IPv4 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clients when the server has more than one LAN interfaces (represented by an IPv4 address string).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2HasUefiFirmware 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.19
Replies whether the system is equipped with UEFI firmware
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

sc2ManagementIpAddressV6 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.20
IPv6 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clients when the server has more than one LAN interfaces (represented by an IPv6 address string).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitTableUpdateCount 1.3.6.1.4.1.231.2.10.2.2.10.2.4
Counter defining the update revision of the unit table. This counter is incremented with every table contents change/update.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sc2UnitParentTable 1.3.6.1.4.1.231.2.10.2.2.10.2.5
Parent-child relationship of all units: list the parent of all available units. Only units that have a parent are listed in this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2UnitParents

sc2UnitParents 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2UnitParents  

sc2pUnitId 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2ParentUnit 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.2
Unit identifier of this unit's parent
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2ParentUnitClass 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.3
Parent unit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  UnitClass  

sc2UnitChildTable 1.3.6.1.4.1.231.2.10.2.2.10.2.6
Parent-child relationship of all units: list all children of all available units. Only units that have children are listed in this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2UnitChilds

sc2UnitChilds 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2UnitChilds  

sc2cUnitId 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cChildNr 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.2
Child number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2ChildUnit 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.3
Child unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2ChildUnitClass 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.4
Unit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  UnitClass  

sc2Management 1.3.6.1.4.1.231.2.10.2.2.10.3
OBJECT IDENTIFIER    

sc2ManagementNodeTable 1.3.6.1.4.1.231.2.10.2.2.10.3.1
SNMP management node addresses (how to address the units)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2ManagementNodes

sc2ManagementNodes 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2ManagementNodes  

sc2mnUnitId 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2mnNodeNr 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.2
Management node address number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2UnitNodeIfType 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.3
Management node interface type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ip(2), ipx(3), ip-v6(4)  

sc2UnitNodeAddress 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.4
Management node address (e.g. 192.168.0.100)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitNodeIpNetmask 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.5
Management node address (e.g. 255.255.255.128)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitNodeGateway 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.6
Management node address (e.g. 192.168.0.126)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitNodeName 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.7
Management node name (DNS name, e.g. apollo.ts.fujitsu.com)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitNodeClass 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.8
Management node class: primary: local operating system interface secondary: local management controller LAN interface management-blade: management blade interface (in a blade server chassis) secondary-remote: remote management controller (in an RSB concentrator environment) secondary-remote-backup: backup remote management controller baseboard-controller: local baseboard management controller (BMC)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), primary(2), secondary(3), management-blade(4), secondary-remote(5), secondary-remote-backup(6), baseboard-controller(7)  

sc2UnitNodeMacAddress 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.9
Management node hardware (MAC) address
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

sc2UnitNodeUseDHCP 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.10
Management node uses DHCP to obtain its address
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), use-fixed-address(2), use-dhcp(3)  

sc2UnitNodeControllerType 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.11
The type of the remote management controller (for identification), like 'RSB', 'RSB S2', 'RSB S2 LP'... These names will not be changed if defined once.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitNodeControllerModel 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.12
The model name of the remote management controller (for displaying), like 'Remote Service Board', 'RemoteView Service Board S2'... This name should not be used for identification, only for displaying (can be changed in different firmware versions)!
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitNodeControllerFWVersion 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.13
The FW version of the remote management controller
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UnitNodeControllerStorage 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.14
Status of the controller specific external storage used for the system management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), available-sdcard(3)  

sc2UnitNodeSNMPEnabled 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.15
SNMP interface is enabled at management node
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2UnitNodeCIMEnabled 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.16
CIM protocol is enabled at management node
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2UnitNodeRemoteIPMIEnabled 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.17
Remote IPMI is enabled at management node
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2NodeTableUpdateCount 1.3.6.1.4.1.231.2.10.2.2.10.3.2
Counter defining the update revision of the management node table. This counter is incremented with every table contents change/update.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sc2ManagementChannelType 1.3.6.1.4.1.231.2.10.2.2.10.3.3
The type of the management channel currently used (this MIB instance).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), primary(2), secondary(3)  

sc2ManagementProcessorTable 1.3.6.1.4.1.231.2.10.2.2.10.3.4
System management service processors
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2ManagementProcessors

sc2ManagementProcessors 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2ManagementProcessors  

sc2spUnitId 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2spProcessorNr 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.2
Service processor number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2spModelName 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.3
Service processor model name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2spFirmwareVersion 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.4
Service processor firmware version / revision
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2spBatteryStatus 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.5
Service processor backup battery status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), on-battery(4), recharging(5), failed(6), discharging(7)  

sc2spBatteryDischargeTime 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.6
Maximum time (in seconds) this backup battery can discharged, after that a shutdown will be performed (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2spTimeOnBattery 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.7
Time (in seconds) the service processor is running on battery since power fail (will be cleared on power recovery)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sc2spDoBatteryChargeCycle 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.8
Perform a discharge/charge cycle on the backup battery by writing a non-zero value. Reading this object just returns the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sc2spBatteryChargeLevel 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.9
Reads the current charge level of the rechargeable battery (in percent of the maximum capacity).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2ManagedUpsNodeTable 1.3.6.1.4.1.231.2.10.2.2.10.3.5
UPS nodes managed by the units
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2ManagedUpsNodes

sc2ManagedUpsNodes 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2ManagedUpsNodes  

sc2upsUnitId 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2upsNr 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.2
UPS number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2upsVendorName 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.3
UPS vendor name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2upsModelName 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.4
UPS model name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2upsMgmtAddress 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.5
UPS management interface target address (represented as string; may contain an IP V4 address, IP V6 address or a URL)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2upsMibRoot 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.6
UPS MIB root OID; specifies the root OID of the MIB to be used to query UPS via SNMP (empty string if no SNMP agent available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2upsSnmpCommunity 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.7
UPS SNMP community name (empty string if no SNMP agent available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2UpsNodeTableUpdateCount 1.3.6.1.4.1.231.2.10.2.2.10.3.6
Counter defining the update revision of the UPS node table. This counter is incremented with every table contents change/update.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sc2ServerInformation 1.3.6.1.4.1.231.2.10.2.2.10.4
OBJECT IDENTIFIER    

sc2ServerTable 1.3.6.1.4.1.231.2.10.2.2.10.4.1
Table containing information about the available servers
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2Servers

sc2Servers 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2Servers  

sc2srvUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2srvPhysicalMemory 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.2
Size of physical main memory installed (MBytes)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2srvLastBootResult 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.3
Result of last system boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), os-boot-successful(2), diagnostic-boot-successful(3), no-boot-cpu(4), no-bootable-media(5), os-failed-to-load(6), diagnostic-boot-failed(7), hardware-failure(8)  

sc2srvCurrentBootStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.4
Status of the current boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), off(2), no-boot-cpu(3), self-test(4), setup(5), os-boot(6), diagnostic-boot(7), os-running(8), diagnostic-running(9), os-shutdown(10), diagnostic-shutdown(11), reset(12)  

sc2srvShutdownCommand 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.5
Shutdown the server and switch off or reset; a delay (see object below) can be defined before the command is being executed; when reading that value, always unknown(1) is replied; argument tells what kind of action: power-on: switch power on power-off: switch power off power-cycle: switch power off and switch power on again. shutdown-and-off: execute a shutdown then power off shutdown-and-reset: execute a shutdown then reset shutdown-and-power-cycle: execute a shutdown then power off and on again raise-nmi: raise an NMI (normally causes debugger to start) reset: execute a reset (without shutdown) The value unknown(1) cannot be set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), power-off(2), power-on(3), power-cycle(4), shutdown-and-off(5), shutdown-and-reset(6), shutdown-and-power-cycle(7), raise-nmi(8), abort-pending-command(9), reset(10)  

sc2srvShutdownDelay 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.6
Delay time (seconds) the agent waits before executing the shutdown command (see previous command). 0 = immediate action, no delay -1 = unknown (delay not supported) The value unknown(-1) cannot be set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sc2srvUUID 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.7
Universal Unique ID (UUID) number (as specified in RFC 4122; shown in network byte order, big-endian) - this is a world-wide unique ID number of the server. Can be used for identifying a server. The format is like this: '33221100-5544-7766-8899-AABBCCDDEEFF'
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2srvPhysicalMemoryOs 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.8
Size of physical main memory available to the operating system (MBytes). This value is similar to 'sc2srvPhysicalMemory', but may be less if the system has mirror or hot spare memory modules.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2srvUUIDWireFormat 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.9
Universal Unique ID (UUID) number (shown in the wire format; little-endian for the first three fields, as consistently used in the PC industry) - this is a world-wide unique ID number of the server. Can be used for identifying a server. The format is like this: '00112233-4455-6677-8899-AABBCCDDEEFF'
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2srvOsPlatform 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.10
Reports about the current operating system platform (x86, x64)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), intel-x86(2), intel-x64(3)  

sc2srvBiosVersion 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.11
System BIOS version
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2srvHasEncryptedPartitions 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.12
Specifies whether encrypted file systems (e.g. by Windows BitLocker) are used (may prevent from BIOS updates)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2srvTrustedExecutionTechnologyEnabled 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.13
Specifies whether Intel Trusted Execution Technology (TXT) is enabled (may prevent from BIOS updates)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2UnitPowerOnOffTable 1.3.6.1.4.1.231.2.10.2.2.10.4.2
Unit power-on and -off information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2UnitPowerOnOff

sc2UnitPowerOnOff 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2UnitPowerOnOff  

sc2ooUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PowerOnOffStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.2
Current power on/off status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3)  

sc2LastPowerOffSource 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.3
Reason why the system was switched off last time
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), swoff-command(2), power-button(3), ac-fail(4), clock(5), fan-fail(6), temperature-critical(7), temperature-damage(8), power-supply-failure(9), watchdog(10), remote-off(11), hardware-fail(12), peripheral-bus-error(13), cpu-error(14), nmi(20), hardware-reset(23), warmstart(24), reset-button(25), ac-fail-reboot(26), keyboard(29), remote-manager(31), remote-manager-reset(32), power-cycle(33), power-limiting(35), mmb-continuous-operation(36), watchdog-power-cycle(37), viom-inventory-board(38), viom-init-boot(39), repeated-fan-fail(40), repeated-temperature-critical(41), firmware-restart(242), housing-opened(243)  

sc2LastPowerOnSource 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.4
Source the system was switched on from
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), swoff-command(2), power-button(3), ac-fail(4), clock(5), fan-fail(6), temperature-critical(7), temperature-damage(8), power-supply-failure(9), watchdog(10), remote-on(11), hardware-fail(12), peripheral-bus-error(13), cpu-error(14), nmi(20), hardware-reset(23), warmstart(24), reset-button(25), ac-fail-reboot(26), mgmt-processor-fail(27), pci-pme(28), keyboard(29), chipcard-reader(30), remote-manager(31), remote-manager-reset(32), power-cycle(33), viom-inventory-board(38), viom-init-boot(39), firmware-restart(242), housing-closed(243)  

sc2LastPowerOnTime 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.5
Time and date (UTC) the system was booted (seconds since 1/1/1970; 0 = unknown or not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PowerOnCounts 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.6
Tells how often the server was switched on in its life (0 = unknown or not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PowerOnDuration 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.7
Tells how long the system has stayed ON in its life (in seconds; 0 = unknown or not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PowerOffDuration 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.8
Tells how long the system has stayed OFF in its life (in seconds; 0 = unknown or not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PowerFailRecovery 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.9
Action on AC power recovery after AC has failed. not-available(2) : function not available, behavior is hardware-defined. as-before(3) : server gets the same power state as before the AC fail. remain-off(4) : server remains off on power resume. switch-on(5) : server is always switched on on power resume. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), as-before(3), remain-off(4), switch-on(5)  

sc2PowerCommand 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.10
Switch the unit on or off; mainly used for extension cabinets; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switch power off and switch power on again No graceful system shutdown is performed - use sc2srvShutdownCommand if shutdown of a server is requested! The value unknown(1) cannot be set and will be delivered if the object is read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3), power-cycle(4)  

sc2PowerSupplyRedundancy 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.11
Specifies whether the power supply system contains redundant power supplies and whether redundancy is available
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2PowerSupplyMatchStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.12
Status of power supply matching - 'ok' if power supplies do not mismatch
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), mismatch(3)  

sc2PerformanceTable 1.3.6.1.4.1.231.2.10.2.2.10.4.3
Server performance and utilisation information (Obsolete! Please use sc2PerformanceValueTable!)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2Performance

sc2Performance 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2Performance  

sc2perfUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2perfNr 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.2
Server performance entry number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PerformanceType 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.3
Server performance object type (description see below)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cpu(1), cpu-overall(2), pci-load(3), pci-efficiency(4), pci-transfer(5), memory-physical(6), memory-total(7), memory-percent(8)  

sc2PerformanceObjectNr 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.4
Server performance object number (0..n; for types with multiple objects)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PerformanceName 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.5
Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2PerformanceValue 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.6
Server performance value (value interpretation depending on type; 0xffffffff = unknown): cpu: Load of a single CPU in percent cpu-overall: Overall CPU load in percent pci-load: PCI bus load in percent pci-efficiency: PCI bus efficiency in percent (100% is optimum) pci-transfer: PCI bus transfer rate in MBytes/sec. memory-physical: Physical memory usage in MBytes memory-total: Total memory usage (physical + virtual) in MBytes memory-percent: Physical memory usage in percent
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2TimerOnOffTable 1.3.6.1.4.1.231.2.10.2.2.10.4.4
Power on/off timer table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2TimerOnOff

sc2TimerOnOff 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2TimerOnOff  

sc2tooUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2tooDayOfWeek 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.2
Day of the week the times should act upon (index); 1=Sunday, 2=Monday...
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2OnTime 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.3
Time the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sc2OffTime 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.4
Time the system should be switched off (by the real-time clock of software; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sc2PowerMonitoringTable 1.3.6.1.4.1.231.2.10.2.2.10.4.5
Power monitoring table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2PowerMonitoring

sc2PowerMonitoring 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2PowerMonitoring  

sc2pmUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2pmCurrentPowerMonitoringAvailable 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.2
Power monitoring and control available on this server: true: Power monitoring and power control is available false: Power monitoring and power control is not available
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

sc2pmCurrentPowerMonitoringEnabled 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.3
Power monitoring enable value: true: Power monitoring and data gathering is enabled false: Power monitoring and data gathering is disabled or not available
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

sc2pmNominalPowerConsumption 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.4
Nominal (maximum) value of the system's power consumption (in Watts; -1 if value not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2pmCurrentPowerConsumption 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.5
Current value of the system's power consumption (in Watts; -1 if value not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2pmCurrentPowerControl 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.6
Power mode control value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption limited: The baseboard management controller controls power consumption by power limit low-noise: The baseboard management controller controls the power to ensure running with lowest noise
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), best-performance(3), minimum-power(4), automatic(5), limited(7), low-noise(8)  

sc2pmPowerLimitStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.7
Power limitation status (valid if power control = limited) ok: power consumption is within specified range warning: power consumption is above warning threshold (sc2pmPowerLimitWarning) but below limit error: power consumption is above limit (sc2pmPowerLimitThreshold) disabled: power consumption limiting is disabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), warning(3), error(4), disabled(5)  

sc2pmPowerLimitThreshold 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.8
Maximum limit value of the system's power consumption (in Watts; -1 if value not available; only valid if limiting enabled)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2pmPowerLimitWarning 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.9
Warning limit level (in percent of the maximum limit threshold; 0 if value not available; only valid if limiting enabled)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2pmRedundancyCritLevel 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.10
Upper critical power consumption level (in Watts; -1 if value not available); power supply redundancy lost if level is exceeded
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2pmPowerControlMode 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.11
Configured power control mode value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption scheduled: The baseboard management controller controls power consumption by schedule limited: The baseboard management controller controls power consumption by power limit low-noise: The baseboard management controller controls the power to ensure running with lowest noise
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), best-performance(3), minimum-power(4), automatic(5), scheduled(6), limited(7), low-noise(8)  

sc2pmPowerDisplayUnit 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.12
Configurd unit for the display of power consumption values: Watt: Power consumption values are displayed in Watts Btu/h: Power consumption values are displyed in Btu
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), watt(2), btu(3)  

sc2UtilizationHistoryTable 1.3.6.1.4.1.231.2.10.2.2.10.4.6
Utilization history table (for power consumption); table only contains existing values (no values for non-existing values)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2UtilizationHistory

sc2UtilizationHistory 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2UtilizationHistory  

sc2uthUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2uthEntity 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.2
Utilization value entity; describes what kind of value to be requested: powerConsumptionDay: power consumption values of the last 24 hours; one value (Watts) per minute powerConsumptionMonth: power consumption values of the last month; one value (Watts) per hour powerConsumptionYear: power consumption values of the last year; one value (Watts) per day
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER powerConsumptionDay(1), powerConsumptionMonth(2), powerConsumptionYear(3)  

sc2uthTimeStamp 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.3
Time stamp of the currenty history entry (time_t = seconds since 1/1/1970, 0:00 AM as GMT)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2uthHardwareUUID 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.4
UUID of the hardware instance that delivered the value (from object sc2srvUUID); may change if an installation is migrated to another hardware (e.g. in blade environments)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2uthAverageValue 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.5
Average value (in Watts) within the monitored time period (minute, hour, day)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2uthMinValue 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.6
Minimum (lowest) value within the monitored time period
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2uthMaxValue 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.7
Maximum (highest) value within the monitored time period
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2PowerSourceInformationTable 1.3.6.1.4.1.231.2.10.2.2.10.4.7
Power source information table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2PowerSourceInformation

sc2PowerSourceInformation 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2PowerSourceInformation  

sc2psiUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2psiPowerSourceType 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.2
System input power source type (e.g. 'AC', 'DC')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2psiPowerSourcePhase 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.3
System input phase of power source.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), single-phase(2), three-phase(3)  

sc2psiPowerSourceVoltage 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.4
System nominal input voltage of power source (in Volts; -1 if value not available).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2VirtualIoManagerTable 1.3.6.1.4.1.231.2.10.2.2.10.4.8
Virtual I/O Manager (VIOM) information table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2VirtualIoManager

sc2VirtualIoManager 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2VirtualIoManager  

sc2viomUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2viomCurrentManagerId 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.2
Identification string of the VIOM manager that currently manages this server
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2viomEnabled 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.3
True if the server is enabled for VIOM
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2viomBiosSupport 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.4
True if the BIOS supports VIOM
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2viomConnectionStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.5
The connection status for VIOM - bit field: Bit 0 - waiting for VIOM table Bit 1 - waiting for inventory table Bit 2 - waiting for external power-on event
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PowerSupplyRedundancyConfigurationTable 1.3.6.1.4.1.231.2.10.2.2.10.4.9
Power Supply redundancy configuration table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2PowerSupplyRedundancyConfiguration

sc2PowerSupplyRedundancyConfiguration 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2PowerSupplyRedundancyConfiguration  

sc2PSRedUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PSRedundancyMode 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.2
Configured power supply redundancy mode; configured in Server Configuration
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-specified(2), no-redundancy(3), psu-redundancy(4), dual-ac-redundancy(18), triple-ac-redundancy(34)  

sc2PSRedundancyModeConfig 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.3
Configuration of number required power supplies for the different redundancy modes specified in sc2PSRedundancyMode: no-redundancy(2): no redundancy required redundancy-1-1(19): 1 required + 1 spare PSU (psu-redundancy mode) or 1 PSU per AC phase (dual-ac-redundancy mode) redundancy-2-1(35): 2 required + 1 spare PSU (psu-redundancy mode) redundancy-3-1(51): 3 required + 1 spare PSU (psu-redundancy mode) redundancy-2-2(36): 2 PSUs per AC phase (dual-ac-redundancy mode)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), no-redundancy(2), redundancy-1-1(19), redundancy-2-1(35), redundancy-2-2(36), redundancy-3-1(51)  

sc2PSRedundancyRequiredPowerSupplies 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.4
Number of power supplies required for configured redundancy mode
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PSRedundancyPopulatedPowerSupplies 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.5
Number of power supplies populated for configured redundancy mode
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PSRedundancyConfigurationStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.6
Status of the redundancy configuration; reports the status about whether enough power supplies are installed to operate at the configured redundancy mode
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2PSRedundancyThresholdStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.7
Status of redundancy threshold; reports the status about whether the actual power consumption exceeds the maximum power consumption level for the configured redundancy mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2PSRedundancyStatus 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.8
Status of power supply redundancy; similar to sc2PowerSupplyRedundancy, but with additional status evaluation according to the power supply redundancy configuration. not-available(2): redundancy not required and not available (no error) ok(3): redundancy required and available warning(4): redundancy required but not available error(5): redundancy required but severe problem detected
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), ok(3), warning(4), error(5)  

sc2PerformanceValueTable 1.3.6.1.4.1.231.2.10.2.2.10.4.10
Server performance and utilisation values
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2PerformanceValues

sc2PerformanceValues 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2PerformanceValues  

sc2PerfValUnitId 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.1
Unit identifier (index, 1..n). For performacne values on local system use 1!
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PerfValType 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.2
Server performance object type (description see below)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER physicalMemoryUsageMb(1), physicalMemoryUsagePercent(2), totalMemoryUsageMb(3), totalMemoryUsagePercent(4), overallCpuUsagePercent(5), logicalCpuUsagePercent(6)  

sc2PerfValObjectNr 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.3
Server performance object number (1..n; for types with multiple objects)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PerfValName 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.4
Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2PerfValCurrentValue 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.5
Server performance value (value interpretation depending on type; 0xffffffff = unknown): physicalMemoryUsageMb: Physical memory usage in MBytes physicalMemoryUsagePercent: Physical memory usage in percent totalMemoryUsageMb: Total memory usage (physical + virtual) in MBytes totalMemoryUsagePercent: Total memory usage (physical + virtual) in percent overallCpuUsagePercent: Overall CPU load in percent logicalCpuUsagePercent: Load of a single CPU in percent
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2Environment 1.3.6.1.4.1.231.2.10.2.2.10.5
OBJECT IDENTIFIER    

sc2TemperatureSensorTable 1.3.6.1.4.1.231.2.10.2.2.10.5.1
Temperature sensors
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2TemperatureSensors

sc2TemperatureSensors 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2TemperatureSensors  

sc2tempUnitId 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2tempSensorNr 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.2
Temperature sensor number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2tempSensorDesignation 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.3
Temperature sensor designation (e.g. TEMP-PS1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2tempSensorIdentifier 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.4
Temperature sensor identification string (e.g. TEMP-RSB1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2tempSensorStatus 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.5
Status of the temperature sensor
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), ok(3), sensor-failed(4), failed(5), temperature-warning-toohot(6), temperature-critical-toohot(7), temperature-normal(8), temperature-warning(9)  

sc2tempCurrentTemperature 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6
Current temperature at this sensor (degrees Celsius; 0 if unknown or sensor failed)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2tempWarningLevel 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.7
Maximum temperature - warning level (degrees Celsius; 0 if unknown or undefined)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2tempCriticalLevel 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.8
Maximum temperature - critical level (degrees Celsius; 0 if unknown or undefined), system shutdown may occur if this level is exceeded
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2tempCriticalReaction 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.9
Reaction if temperature exceeds the critical level (the value unknown(1) cannot be set)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), shutdown-and-poweroff(3)  

sc2FanTable 1.3.6.1.4.1.231.2.10.2.2.10.5.2
Cooling devices (fans, liquid cooling pumps)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2Fans

sc2Fans 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2Fans  

sc2fanUnitId 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2fanNr 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.2
Cooling device number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2fanDesignation 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.3
Cooling device designation (e.g. FAN-PS1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2fanIdentifier 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.4
Cooling device identification string (e.g. FAN-1-POWERSUPPLY)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2fanStatus 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.5
Status of the cooling device
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), ok(3), failed(4), prefailure-predicted(5), redundant-fan-failed(6), not-manageable(7), not-present(8)  

sc2fanCurrentSpeed 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.6
Current cooling device speed (revolutions per minute; 0 if unknown or failed)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2fanQuality 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.7
Quality of cooling device (in percent of nominal speed - measured at full speed)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2fanFailReaction 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.8
Reaction if the cooling device fails (the value unknown(1) cannot be set)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), shutdown-and-poweroff(3)  

sc2fanFailShutdownDelay 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.9
Delay time (in seconds) when shutdown should commit on cooling device fail (if shutdown-and-off is configured; 0 = immediately, -1 = unknown, cannot be set)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sc2fanCoolingDeviceType 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.10
Type of cooling device (whether fan or liquid cooling pump) fan(2): fan liquid(3): liquid cooling pump
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), fan(2), liquid(3)  

sc2AirflowTable 1.3.6.1.4.1.231.2.10.2.2.10.5.3
Exhaust airflow volume table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2Airflow

sc2Airflow 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2Airflow  

sc2afUnitId 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2afExhaustAirflowVolume 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.2
System exhaust airflow volume ('-1' if value not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2afExhaustAirflowVolumeUnit 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.3
System exhaust airflow volume unit (e.g. 'cbm/h', 'ccm/min', ...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2Hardware 1.3.6.1.4.1.231.2.10.2.2.10.6
OBJECT IDENTIFIER    

sc2SystemBoardTable 1.3.6.1.4.1.231.2.10.2.2.10.6.1
System board (main board) information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2SystemBoard

sc2SystemBoard 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2SystemBoard  

sc2sbUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2sbBoardNr 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.2
System board number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2SystemBoardModelName 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.3
Model name (e.g. 'D1297')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2SystemBoardProductNumber 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.4
Product number (may be identical to ModelName)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2SystemBoardRevision 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.5
Revision string (e.g. 'WGS1 GS3')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2SystemBoardSerialNumber 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.6
Serial number (not available for all boards)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2SystemBoardDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.7
Designation (important when multiple system boards are available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2SystemBoardSDCardSlotPresent 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.8
System board contains SD card slot
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2PowerSupplyTable 1.3.6.1.4.1.231.2.10.2.2.10.6.2
Power supplies
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2PowerSupply

sc2PowerSupply 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2PowerSupply  

sc2psUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2psPowerSupplyNr 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.2
Power supply (bay) number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2PowerSupplyDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.3
Power supply designation (e.g. PS1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2PowerSupplyIdentifier 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.4
Power supply identification string (e.g. PS1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2PowerSupplyStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.5
Power supply status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), failed(4), ac-fail(5), dc-fail(6), critical-temperature(7), not-manageable(8), fan-failure-predicted(9), fan-failure(10), power-safe-mode(11), non-redundant-dc-fail(12), non-redundant-ac-fail(13)  

sc2psPowerSupplyLoad 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.6
Actual power supply output load in Watts (0 = not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2psPowerSupplyNominal 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.7
Nominal power supply output load in Watts (0 = not available), the maximum value the power supply can provide
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2VoltageTable 1.3.6.1.4.1.231.2.10.2.2.10.6.3
Voltages - all voltage values are in 1/100th Volts; a value of 330 means 3.30 Volts (0xffffffff = unknown)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2Voltages

sc2Voltages 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2Voltages  

sc2voUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2voSensorNr 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.2
Voltage sensor number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2VoltageDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.3
Voltage designation string (e.g. 12V, 3V3, ...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2VoltageStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.4
Voltage status not-available(2): no voltage available (e.g. CPU voltage on empty CPU socket) ok(3): voltage value is in normal range too-low(4): voltage value is below nominal range too-high(5): voltage value is above upper limit out-of-range(6): voltage value is out of normal range (cannot detect whether too low or too high) warning(7): voltage warning (e.g. battery failure predicted)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), ok(3), too-low(4), too-high(5), out-of-range(6), warning(7)  

sc2VoltageCurrentValue 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.5
Voltage current value (in mV; 0xFFFFFFFF = unknown; negative voltages are reported as negative values: -1770 (0xFFFFF916) means -1.77 Volts)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2VoltageNominalValue 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.6
Voltage nominal value (in mV; -1 = unknown; negative voltages are reported as negative values)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2VoltageMinimumLevel 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.7
Voltage minimum level (in mV; -1 = unknown; negative voltages are reported as negative values)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2VoltageMaximumLevel 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.8
Voltage maximum level (in mV; -1 = unknown; negative voltages are reported as negative values)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2VoltageCurrentLoad 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.9
Current output load on this voltage line, in percent of the maximum load (0xFFFFFFFF = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sc2CPUTable 1.3.6.1.4.1.231.2.10.2.2.10.6.4
CPU description table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2CPUs

sc2CPUs 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2CPUs  

sc2cpuUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuNr 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.2
CPU (socket) number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.3
CPU designation (e.g. CPU-2)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2cpuStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.4
CPU status: unknown(1): CPU status could not be evaluated not-present(2): CPU socket is empty ok(3): CPU is available and working properly disabled(4): CPU was manually disabled in BIOS setup error(5): CPU has encountered errors but is still in use failed(6): CPU has failed and is disabled missing-termination(7): CPU socket needs a terminator module when not populated but the terminator is missing prefailure-warning(8): CPU has encountered too many correctable errors within a certain time period and is predicted to fail in near future
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), disabled(4), error(5), failed(6), missing-termination(7), prefailure-warning(8)  

sc2cpuModelName 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.5
CPU model name (e.g. Pentium Xeon)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2cpuManufacturer 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.6
CPU manufacturer name (e.g. Intel)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2cpuStep 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.7
CPU step / revision
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2cpuCurrentSpeed 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.8
CPU speed (frequency in MHz, -1 if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuNumberLogicals 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.9
Number of (physically available) logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical CPUs of a hyper-threading CPU, -1 if unknown or not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuCacheL1Size 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.10
Size of first level cache (in kBytes, 0 if unknown or not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuCacheL2Size 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.11
Size of second level cache (in kBytes, 0 if unknown or not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuCacheL3Size 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.12
Size of third level cache (in kBytes, 0 if unknown or not available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuNumberCores 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.13
Number of (physically available) cores within one physical CPU (for multi-core CPUs, platform dependent), 0 if unknown or not available
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuFamily 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.14
CPU family code. This enumerated value is specified by the DMTF SMBIOS specification (processor information, type 4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuEnabledCores 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.15
Number of effectively enabled cores within one physical CPU (for multi-core CPUs; 0 if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuMultithreadingEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.16
Multithreading of CPU enabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), enabled(3)  

sc2cpuConfigurationStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.17
CPU configuration status: unknown(1): CPU status could not be evaluated normal(2): Regular CPU configuration disabledManually(3): CPU was manually disabled (in BIOS setup) hotSpare(4): CPU is a hot-spare CPU (for future use) mirror(5): CPU is mirrored (for future use) notUsable(7): CPU is currently not usable (due to configuration problems) configurationError(8): CPU misconfiguration
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), disabledManually(3), hotSpare(4), mirror(5), notUsable(7), configurationError(8)  

sc2cpuMCDRAMSize 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.18
Size of the onboard MCDRAM (GByte; 0 if no MCDRAM is available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuMCDRAMSpeed 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.19
Speed of the onboard MCDRAM (MT/s; 0 if no MCDRAM is available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuMCDRAMMode 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.20
Operation mode of the onboard MCDRAM: undefined(1): Mode is not defined (no MCDRAM available) flat(2): MCDRAM is used as standalone memory exclusively or in addition to external RAM cache(3): MCDRAM is used as a cache for external RAM hybrid(3): Part of MCDRAM is used as a cache, rest as standalone memory (see sc2cpuMCDRAMCacheSize)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), flat(2), cache(3), hybrid(3)  

sc2cpuMCDRAMCacheSize 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.21
Portion of the onboard MCDRAM used as a cache in hybrid mode (in percent; 0 if no MCDRAM is available or other mode than hybrid)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpuMCDRAMMemoryModel 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.22
Memory model of the onboard MCDRAM: undefined(1): Model is not defined (no MCDRAM available) all2all(2): All2All subNumaCluster2(3): Sub NUMA Cluster - 2 subNumaCluster4(4): Sub NUMA Cluster - 4 hemisphere(5): Hemisphere mode quadrant(6): Quadrant mode
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), all2all(2), subNumaCluster2(3), subNumaCluster4(4), hemisphere(5), quadrant(6)  

sc2MemoryModuleTable 1.3.6.1.4.1.231.2.10.2.2.10.6.5
Main memory module table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2MemoryModules

sc2MemoryModules 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2MemoryModules  

sc2memUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2memModuleNr 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.2
Memory module (socket) number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2memModuleDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.3
Memory module designation (e.g. DIMM-2)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2memModuleStatus 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.4
Memory module status: unknown(1): Module status could not be evaluated not-present(2): Module socket is empty ok(3): Module is available and working properly disabled(4): Module was manually disabled in BIOS setup error(5): Module has encountered errors but is still in use failed(6): Module has failed and was disabled prefailure-predicted(7): Module has encountered too many correctable errors within a certain time period and is predicted to fail in near future hidden(11): Module socket is not available and should be hidden
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), disabled(4), error(5), failed(6), prefailure-predicted(7), hot-spare(8), mirror(9), raid(10), hidden(11)  

sc2memModuleBank 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.5
Memory module bank number (-1 if unknown) Due to the fact that modern mainboards do no longer have fixed banks, this value is OBSOLETE!
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2memModuleCapacity 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.6
Memory module size (capacity in MBytes; -1 if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2memModuleStartAddress 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.7
Memory module start address (in MBytes; -1 if unknown) Due to the fact that modern mainboards do no longer show start addresses, this value is OBSOLETE!
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2memModuleForm 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.8
Memory module form (SIMM, DIMM, ...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2memModuleType 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.9
Memory module type (SDRAM, DDRAM, DDR2, DDR3, ...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2memModuleCorrErrors 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.10
Number of memory module correctable errors (-1 if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sc2memModuleUncorrErrors 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.11
Number of memory module uncorrectable errors (-1 if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sc2memModuleApproved 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.12
Memory module approved for this machine
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), no(2), yes(3)  

sc2memModuleConfiguration 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.13
Memory module configuration: unknown(1): Module configuration could not be evaluated normal(2): Module is in normal non-redundant configuration or slot is empty disabled(3): Module is disabled (manually through BIOS setup) hotSpare(4): Module is a hot-spare (standby) module, which will be used as a run-time-replacement for failed modules mirror(5): Module is part of a mirror configuration raid(6): Module is part of a RAID configuration notUsable(7): Module is not usable in the actual configuration because of architectural restrictions configurationError(8): Module is not active due to memory misconfiguration This object replaces the previous redundancy status values hot-spare and mirror in sc2memModuleStatus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), disabled(3), hotSpare(4), mirror(5), raid(6), notUsable(7), configurationError(8)  

sc2memModuleFrequency 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.14
Memory module actual front side bus frequency (in MHz; -1 if unknown). This value is based on the BIOS settings
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2memModuleMaxFrequency 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.15
Memory module maximum front side bus frequency (in MHz; -1 if unknown). This value is based on memory module SPD data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2memModuleVoltInterface 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.16
Memory module interface voltage interface description
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2cpuMultithreadEnable 1.3.6.1.4.1.231.2.10.2.2.10.6.6
Multithreading of CPU enabled This object is OBSOLETE for future implementations; use object 'sc2cpuMultithreadingEnabled' from 'sc2CPUTable' instead!
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), enabled(3)  

sc2ComponentPowerConsumptionTable 1.3.6.1.4.1.231.2.10.2.2.10.6.7
Table of component power consumption data
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2ComponentPowerConsumption

sc2ComponentPowerConsumption 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2ComponentPowerConsumption  

sc2cpcUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpcComponentClass 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.2
Component class enumeration (based on IPMI v1.0 entity ID)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER processor(3), disk(4), system-board(7), memory-unit(8), processor-module(9), power-supply(10), gpu(11), chassis(23), sub-chassis(24), disk-bay(26), cooling-device(29), cooling-unit(30), memory-device(32), total-power(224)  

sc2cpcComponentIndex 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.3
Component index within class (1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cpcDesignation 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.4
Component designation
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2cpcCurrentValue 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.5
Current component power consumption in Watts
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2TrustedPlatformModuleTable 1.3.6.1.4.1.231.2.10.2.2.10.6.8
Trusted Platform Module (TPM) status information (see corresponding TPM specification for detailed description of these states)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2TrustedPlatformModule

sc2TrustedPlatformModule 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2TrustedPlatformModule  

sc2tpmUnitId 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2tpmHardwareAvailable 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.2
TPM hardware is available ('unknown' if hardware availability cannot be detected; no interface found)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2tpmBiosEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.3
TPM hardware is enabled by BIOS ('unknown' if hardware is not available; a reboot is required to change this value)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2tpmEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.4
TPM is enabled (by software; cannot take ownership if disabled; 'unknown' if hardware is not available or disabled)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2tpmActivated 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.5
TPM is activated (by software; 'unknown' if hardware is not available or disabled)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2tpmOwnership 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.6
TPM ownership is established (valid endorsement key is existing; 'unknown' if hardware is not available or disabled)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2PersistentMemoryModuleTable 1.3.6.1.4.1.231.2.10.2.2.10.6.9
Additional information about persistent (non-volatile) memory modules to extend the sc2MemoryModuleTable. This table uses the index numbers of the previous sc2MemoryModuleTable, but only contains rows where a persistent DIMM module is detected.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2PersistentMemoryModules

sc2PersistentMemoryModules 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2PersistentMemoryModules  

sc2nvmemMemoryModeEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.1
Volatime memory mode is enabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2nvmemPersistentModeEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.2
Persistent memory mode is enabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2nvmemPackageSparingCapable 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.3
Module is capable of providing spare memory
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2nvmemEncryptionEnabled 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.4
Memory encryption is enabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2nvmemFirmwareRevision 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.5
Firmware revision
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2nvmemTotalSize 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.6
Total size of memory module (in GBytes; including reserved spare space)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemRawCapacity 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.7
Maximum capacity that can be allocated for use in any of the supported modes (in GBytes; excluding reserved space)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemVolatileCapacity 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.8
Capacity of volatile memory (in GBytes)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemPersistentCapacity 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.9
Capacity of persistent memory (in GBytes)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemVolatilePercent 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.10
Capacity of volatile memory (in percent of total size)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemPersistentPercent 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.11
Capacity of persistent memory (in percent of total size)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemVolatileStart 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.12
Start address of the volatile memory region
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2nvmemPersistentStart 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.13
Start address of the persistent memory region
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2nvmemHealthStatusNonCritical 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.14
Non-critical (warning) status
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2nvmemHealthStatusCritical 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.15
Critical status
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2nvmemHealthStatusFatal 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.16
Fatal error status (data loss has occurred or is imminent)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalseUnknown  

sc2nvmemPowerOnTime 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.17
Lifetime the DIMM has been powered on (in seconds)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemUpTime 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.18
Current uptime of the DIMM for the current power cycle (in seconds)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemLiftetimeRemaining 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.19
Remaining predicted lifetime (in seconds; -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemAveragePowerBudget 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.20
Average Power Budget in mW
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2nvmemPeakPowerBudget 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.21
Peak Power Budget in mW
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2Recovery 1.3.6.1.4.1.231.2.10.2.2.10.7
OBJECT IDENTIFIER    

sc2MessageLogTable 1.3.6.1.4.1.231.2.10.2.2.10.7.1
Error and event message handling
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2MessageLogs

sc2MessageLogs 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2MessageLogs  

sc2msgUnitId 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2msgLogEntryNr 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.2
Message log entry number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2msgLogEntryData 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.3
Message log entry data (binary; one message per table entry)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sc2WatchdogTable 1.3.6.1.4.1.231.2.10.2.2.10.7.2
Watchdogs
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2Watchdogs

sc2Watchdogs 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2Watchdogs  

sc2wdUnitId 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2WatchdogType 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.2
Watchdog type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), hardware(2), software(3), bios(4), boot(5), management-controller(6), remote-management-controller(7), cpu(8)  

sc2WatchdogStatus 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.3
Watchdog status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), enabled(3), not-available(4)  

sc2WatchdogTime 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.4
Watchdog timeout period in seconds (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2WatchdogAction 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.5
Watchdog timeout action; the value unknown(1) can't be written. Not all watchdog type allow setting all of the values (-> BADVALUE).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), reset(4), nmi(5), power-cycle(6)  

sc2RecoverySettingTable 1.3.6.1.4.1.231.2.10.2.2.10.7.3
ASR&R (Automatic server recovery and restart) settings
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2RecoverySettings

sc2RecoverySettings 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2RecoverySettings  

sc2asrUnitId 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2asrNrRebootRetries 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.2
Current number of retries to reboot/restart the server when a failure shutdown (and power-off) had occured. After this number of retries the action defined in 'sc2asrRebootFailAction' will be executed (-1 = unknown, no retries).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2asrDefaultRebootRetries 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.3
Default number of retries for server failure reboot. The above object 'sc2asrNrRebootRetries' will be set to this value after the server is working properly for a certain amount of time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2asrNextBootSource 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.4
Source medium to boot from (next time): operating-system: boot from floppy or hard disk diag-system: boot from alternate diagnostic system (only for SCSI systems, load diagnostic system from alternate IDE disk). remote-disk: boot from remote network disk
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), operating-system(2), reserved(3), diag-system(4), remote-disk(5)  

sc2asrRebootFailAction 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.5
Specifies the action after a specified number of failed reboot retries (the object 'sc2asrNrRebootRetries' has reached zero). The value no-diag-system(4) means that a diagnostics system is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), switch-off(2), boot-diag-system(3), no-diag-system(4), remote-image-disk(5), pxe(6), rsb-usb(7), remote-storage(8), stop-reboot(9), diag-interrupt-assert(10)  

sc2asrRestartDelay 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.6
Delay (in minutes) after that the system should be automatically switched on again (by real-time clock) after an error power-off. Setting this value to zero means immediate restart (power-cycle only). Automatic restart may be disabled by setting the 'sc2asrRebootFailAction' to 'switch-off' and the 'sc2asrDefaultRebootRetries' to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2asrPostErrorHalt 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.7
Describes what to do when a POST error has occured (halt on any error, no halt on any error...).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), halt-on-any-error(2), no-halt-on-any-error(3), other(9)  

sc2MessageTextLogTable 1.3.6.1.4.1.231.2.10.2.2.10.7.4
Error and event message handling, reported as text strings
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2MessageTextLogs

sc2MessageTextLogs 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2MessageTextLogs  

sc2msgTextLogUnitId 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2msgTextLogLanguage 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.2
Message log entry language (index, Windows language code) e.g. 1031, 1033 for German, English (default; always available)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2msgTextLogSeqNr 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.3
Message log entry sequence number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2msgTextLogTimestamp 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.4
Message log entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2msgTextLogMessage 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.5
Message log entry message string (multi-byte string; multi-language; not every language may be implemented)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2msgTextLogErrorCode 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.6
Message log entry error code
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2msgTextLogSeverity 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.7
Message log entry severity
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER informational(1), minor(2), major(3), critical(4)  

sc2msgTextLogCSSComponent 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.8
Component which caused the log message may be replaced by the customer (CSS=Customer Self Service)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

sc2MessageLogActionHintTable 1.3.6.1.4.1.231.2.10.2.2.10.7.5
Action text strings for error and event messages
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2MessageLogActionHints

sc2MessageLogActionHints 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2MessageLogActionHints  

sc2mlaLanguage 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.1
Action text language (index, Windows language code) e.g. 1031, 1033 for German, English
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2mlaErrorCode 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.2
Action text error code (index)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2mlaType 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.3
Message log entry severity
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER summary(1), cause(2), resolution(3)  

sc2mlaIndex 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.4
Action text entry string index (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2mlaMessage 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.5
Action message string
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2Status 1.3.6.1.4.1.231.2.10.2.2.10.8
OBJECT IDENTIFIER    

sc2AgentStatus 1.3.6.1.4.1.231.2.10.2.2.10.8.1
Overall status of all monitored components in this agent ok(1): all components are working properly; no warnings, no errors warning(2): at least one component reports a warning status or a redundant component reports an error status error(3): at least one non-redundant component reports an error status unknown(5): none of the components has a valid status (e.g. during initialization) notPresent(6): none of the components is present notManageable(7): none of the components is manageable
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2StatusComponentTable 1.3.6.1.4.1.231.2.10.2.2.10.8.2
Table with status values of the components in this agent. The table summarizes all instances of one component to one status value.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2StatusComponents

sc2StatusComponents 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2StatusComponents  

sc2csUnitId 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2csStatusOverall 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.2
Overall status (worst status of all components) in this unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2csStatusBoot 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.3
Boot status (errors from power-on selftest and boot)
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2csStatusPowerSupply 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.4
Power supply status
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2csStatusTemperature 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.5
Temperature status
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2csStatusFans 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.6
Fan status
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2csStatusVoltages 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.7
Voltage status
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2csStatusCpu 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.8
CPU status
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2csStatusMemoryModule 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.9
Memory module status
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2ComponentStatusSensorTable 1.3.6.1.4.1.231.2.10.2.2.10.8.3
This table contains the component status sensor table of the BMC (baseboard management controller). Additionally it also holds the CSS (Customer Self Service) information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2ComponentStatusSensors

sc2ComponentStatusSensors 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2ComponentStatusSensors  

sc2cssUnitId 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cssSensorNumber 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.2
BMC component status sensor number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cssSensorDesignation 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.3
Component status sensor designation string
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2cssSensorDevice 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.4
Name of device (entity) the component status sensor belongs to
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2cssSensorDeviceInstance 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.5
Instance number of device (entity) the component status sensor belongs to
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2cssSensorPhysicalLed 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.6
If set, component has a physical status LED showing the sensor status
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

sc2cssSensorCssComponent 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.7
If set, component may be replaced by the customer (CSS 'custormer-self-service' component)
Status: mandatory Access: read-only
OBJECT-TYPE    
  TrueFalse  

sc2cssSensorStatus 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.8
Status returned by the component status sensor
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), identify(3), prefailure-warning(4), failure(5), not-present(6)  

sc2cssComponentServicePartId 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.9
Spare part number of the replaceable component; used to create a link to the spare part list on the service's spare part catalogue. This usually is the component's designation string, with blanks substituted by underscores.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2cssTableSize 1.3.6.1.4.1.231.2.10.2.2.10.8.4
Number of entries in the component status sensor table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2Maintenance 1.3.6.1.4.1.231.2.10.2.2.10.9
OBJECT IDENTIFIER    

sc2MaintenanceObjectTable 1.3.6.1.4.1.231.2.10.2.2.10.9.1
Table containing some other maintenance objects
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2MaintenanceObjects

sc2MaintenanceObjects 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2MaintenanceObjects  

sc2mtUnitId 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2ErrorCounterStartTime 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.2
Memory module error counter start time (seconds since 1/1/1970, -1 if unknown). This is the time when the error counters were started or reset last time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2SendTestTrap 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.3
Send a test trap (test alarm) to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Initiate test trap sending by writing a non-zero value. Reading this object just returns the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sc2AddTrapDestination 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.4
Add the specified IP address (of the management station) to the trap destination list of this server. That client will become an alarm receiver for traps of this server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2FirmwareVersionTable 1.3.6.1.4.1.231.2.10.2.2.10.9.2
Controller firmware version table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2FirmwareVersions

sc2FirmwareVersions 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2FirmwareVersions  

sc2fwUnitId 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2fwType 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.2
Controller/firmware type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bios(1), management-controller(2), remote-management-controller(3)  

sc2fwModelName 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.3
Controller/firmware model name (e.g. 'Copernicus'...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2fwVersion 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.4
Controller/firmware version string (e.g. '3.81.02')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2Deployment 1.3.6.1.4.1.231.2.10.2.2.10.10
OBJECT IDENTIFIER    

sc2DeployInfoTable 1.3.6.1.4.1.231.2.10.2.2.10.10.1
Table with data of deployment information. This table is OBSOLETE (no longer used for new implementations)!
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2DeployInfo

sc2DeployInfo 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2DeployInfo  

sc2dplInfoUnitId 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2DeployInfoChassisId 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.2
Chassis serial number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2DeployInfoMacAddr1 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.3
MAC address 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

sc2DeployInfoMacAddr2 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.4
MAC address 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

sc2DeployInfoMacAddr3 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.5
MAC address 3
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

sc2DeployInfoMacAddr4 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.6
MAC address 4
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

sc2DeployInfoIpAddr1 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.7
IP address 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoIpAddr2 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.8
IP address 2
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoIpAddr3 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.9
IP address 3
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoIpAddr4 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.10
IP address 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoNetMask1 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.11
IP subnet mask 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoNetMask2 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.12
IP subnet mask 2
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoNetMask3 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.13
IP subnet mask 3
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoNetMask4 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.14
IP subnet mask 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoGateway1 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.15
IP gateway 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoGateway2 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.16
IP gateway 2
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoGateway3 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.17
IP gateway 3
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoGateway4 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.18
IP gateway 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sc2DeployInfoHostname 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.19
Host name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sc2DeployInfoMasterImageReference 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.20
URL in UNC notification (but in ASCII) to remote image file (with the extensions of *.img, *.cfg, *.txt)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sc2DeployInfoStatusOfBlade 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.21
Status of this server: power-down(2): waiting for boot standby(3): power management mode system-boot-failure(4): system boot failure bios-setup(5): BIOS setup or boot phase booting(6): ACPI OS currently booting
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), power-down(2), standby(3), system-boot-failure(4), bios-setup(5), booting(6)  

sc2DeployInfoLanStatusOfSlot 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.22
Defines wether the IP-LAN definitions are valid or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), false(2), true(3)  

sc2DeployInfoAutomaticRecovery 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.23
Defines if this server blade should be provided automatic recovery.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), false(2), true(3)  

sc2DeployInfoStatusOfCloning 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.24
Status of current cloning process.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), not-cloned(2), cloning(3), cloned(4)  

sc2DeployInfoBootMode 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.25
Boot mode of the server for remote deployment: normal(2): boot from standard disk subsystem pxeBiosSetup(3): boot from PXE according to BIOS setup settings (for OEM systems) pxeLanx(y): boot from PXE LAN interface x (0..3)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), pxeBiosSetup(3), pxeLan0(4), pxeLan1(5), pxeLan2(6), pxeLan3(7)  

sc2OemDeployInfoTable 1.3.6.1.4.1.231.2.10.2.2.10.10.2
Table with data of server OEM information. This table is OBSOLETE (no longer used for new implementations)!
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2OemDeployInfo

sc2OemDeployInfo 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2OemDeployInfo  

sc2odplInfoUnitId 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2odplParamId 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.2
OEM parameter ID (index, 1..10)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2OemDeployInfoParamData 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.3
OEM parameter data
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sc2DeployLanInterfaceTable 1.3.6.1.4.1.231.2.10.2.2.10.10.3
Table with system LAN interfaces information: This table lists all real LAN interfaces in same physical order as the BIOS uses it for PXE boot. Only on-board interfaces are listed; no virtual interfaces.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2DeployLanInterfaces

sc2DeployLanInterfaces 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2DeployLanInterfaces  

sc2dplLanUnitId 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.1
Unit identifier (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2dplLanInterfaceNr 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.2
LAN interface number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2dplLanMacAddress 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.3
LAN interface hardware (MAC) address
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

sc2DriverMonitoring 1.3.6.1.4.1.231.2.10.2.2.10.11
OBJECT IDENTIFIER    

sc2DriverMonitorComponentTable 1.3.6.1.4.1.231.2.10.2.2.10.11.1
Table of components monitored by the driver monitor. Foreign index sc2uUnitId is from sc2UnitTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2DriverMonitorComponents

sc2DriverMonitorComponents 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2DriverMonitorComponents  

sc2drvmonCompClass 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.1
Component class (index)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), software(2), network(3), storage(4)  

sc2drvmonCompIndex 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.2
Component index (index, 1..n). This is an index over all component classes, but unit specific.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2drvmonCompName 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.3
Name or designation of the component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2drvmonCompType 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.4
Component (bus) type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), pci(2), usb(3)  

sc2drvmonCompDriverName 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.5
Name of the driver that created the event record
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2drvmonCompLocationDesignation 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.6
Device location designation (if it is an adapter or other hardware component); e.g. 'PCI Slot #2' or 'IOB#1-FUNC#0'
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2drvmonCompLocationKey 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.7
Device location key, used for identifying the component in other tables (like PCI device table); e.g. 'TYPE_PCI&BUS_3&DEV_14&FUNC_0'
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2drvmonCompStatus 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.8
Status of the component; caused by specific error events, reset by corresponding 'component OK' events or by manual acknowledge
Status: mandatory Access: read-only
OBJECT-TYPE    
  CompStatus  

sc2drvmonCompErrorAcknowledge 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.9
Acknowledge an error condition (reset error or warning status) of the component by writing a non-zero value (reading this object just returns the value 0)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sc2DriverMonitorMessageTable 1.3.6.1.4.1.231.2.10.2.2.10.11.2
Table of messages gathered by the driver monitor. The messages are based on the monitored operating system event log and are available in translated languages. Foreign indexes: sc2uUnitId is from sc2UnitTable, sc2msgTextLogLanguage from sc2MessageTextLogTable, sc2drvmonCompClass, sc2drvmonCompType and sc2drvmonCompIndex from sc2DriverMonitorComponentTable. When sc2drvmonCompIndex is 0, the event could not be assigned to any component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc2DriverMonitorMessages

sc2DriverMonitorMessages 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc2DriverMonitorMessages  

sc2drvmonMsgSeqNr 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.1
Driver message entry sequence number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2drvmonMsgTimestamp 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.2
Driver message entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2drvmonMsgMessage 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.3
Message entry string (multi-language; not every language may be implemented, then English message has to be requested)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2drvmonMsgEventId 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.4
Message entry error code (this code is a driver monitor specific error code)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2drvmonMsgSeverity 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.5
Message entry severity (may be different from original event log severity)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OsLogSeverity  

sc2drvmonMsgErrorCode 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.6
Message entry error code (must be used to get summary, causes and resolutions from sc2MessageLogActionHintTable table)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2drvmonOrigLogMessage 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.7
Original operating system event log / syslog entry message (only available in the server's original language or in english, depending on the driver that created that entry)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2drvmonOrigLogSource 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.8
Original log entry source name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sc2drvmonOrigLogId 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.9
Original log entry ID number (may not be available for some platforms/controllers, then ID = 0)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sc2drvmonOrigLogSeverity 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.10
Original event log entry severity
Status: mandatory Access: read-only
OBJECT-TYPE    
  OsLogSeverity  

sc2drvmonTableUpdateCount 1.3.6.1.4.1.231.2.10.2.2.10.11.3
Counter defining the update revision of the driver monitoring tables. This counter is incremented with every change/update of the driver monitoring tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sc2NotificationsTrapInfo 1.3.6.1.4.1.231.2.10.2.2.10.20.1
OBJECT IDENTIFIER    

sc2TrapInfoServerName 1.3.6.1.4.1.231.2.10.2.2.10.20.1.1
Name of the server the trap comes from
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString  

sc2TrapInfoTime 1.3.6.1.4.1.231.2.10.2.2.10.20.1.2
Time when the trap occured (in seconds since 01/01/1970 00:00h)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

sc2TrapInfoCabinetNr 1.3.6.1.4.1.231.2.10.2.2.10.20.1.3
Cabinet number generating the trap
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

sc2TrapInfoObjectDesignation 1.3.6.1.4.1.231.2.10.2.2.10.20.1.4
Designation string for object that generated the trap (fan, temperature sensor...)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString  

sc2TrapInfoString 1.3.6.1.4.1.231.2.10.2.2.10.20.1.5
Additional string to be displayed in the trap text
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString  

sc2TrapInfoInteger 1.3.6.1.4.1.231.2.10.2.2.10.20.1.6
Additional number to be displayed in the trap text
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

sc2TrapInfoInteger2 1.3.6.1.4.1.231.2.10.2.2.10.20.1.7
Additional number to be displayed in the trap text
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

sc2TrapTest 2000
Test trap to verify trap connection.
TRAP-TYPE    

sc2TrapCommunicationFailure 2001
The communication with management controller failed!
TRAP-TYPE    

sc2TrapCommunicationEstablished 2002
The communication with the management controller was reestablished
TRAP-TYPE    

sc2TrapControllerSelftestWarning 2003
Controller selftest warning.
TRAP-TYPE    

sc2TrapControllerSelftestError 2004
Controller selftest error.
TRAP-TYPE    

sc2TrapBiosSelftestError 2005
A critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition.
TRAP-TYPE    

sc2TrapSevereSystemError 2006
The system was restarted after a severe problem. See server management message log (recovery log) for detailed information.
TRAP-TYPE    

sc2TrapFanAdded 2010
The indicated hot-plug fan or liquid pump was inserted.
TRAP-TYPE    

sc2TrapFanRemoved 2011
The indicated hot-plug fan or liquid pump was removed.
TRAP-TYPE    

sc2TrapFanOk 2012
The indicated fan or liquid pump is working again.
TRAP-TYPE    

sc2TrapFanCritical 2013
The indicated fan or liquid pump became critical
TRAP-TYPE    

sc2TrapFanFailed 2014
The indicated fan or liquid pump failed.
TRAP-TYPE    

sc2TrapRedundantFanFailed 2015
The indicated redundant fan or liquid pump failed
TRAP-TYPE    

sc2TrapTempOk 2020
The temperature of the indicated sensor has decreased to the normal level.
TRAP-TYPE    

sc2TrapTempWarning 2021
The temperature of the indicated sensor has reached the warning level.
TRAP-TYPE    

sc2TrapTempCritical 2022
The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled.
TRAP-TYPE    

sc2TrapTempSensorOk 2023
The indicated broken temperature sensor is OK again.
TRAP-TYPE    

sc2TrapTempSensorBroken 2024
The indicated temperature sensor is broken.
TRAP-TYPE    

sc2TrapPowerSupplyAdded 2030
One hot-replace power supply was added.
TRAP-TYPE    

sc2TrapPowerSupplyRemoved 2031
One hot-replace power supply was removed
TRAP-TYPE    

sc2TrapPowerSupplyOk 2032
Power supply is working again.
TRAP-TYPE    

sc2TrapPowerSupplyCritical 2033
Power supply status has become critical.
TRAP-TYPE    

sc2TrapPowerSupplyFailed 2034
One hot-replace power supply failed.
TRAP-TYPE    

sc2TrapRedundantPowerSupplyFailed 2035
One redundant hot-replace power supply failed
TRAP-TYPE    

sc2TrapPowerSupplyRedundancyLost 2036
Power supply redundancy no longer available.
TRAP-TYPE    

sc2TrapPowerSupplyCriticalTemperature 2037
Critical temperature in power supply.
TRAP-TYPE    

sc2TrapPowerSupplyFanFailurePrediction 2038
Fan failure prediction in power supply.
TRAP-TYPE    

sc2TrapPowerSupplyFanFailure 2039
Fan failure in power supply.
TRAP-TYPE    

sc2TrapAcFail 2040
Mains failed in the specified cabinet. This trap can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this trap.
TRAP-TYPE    

sc2TrapDcFail 2041
DC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs.
TRAP-TYPE    

sc2TrapOnBattery 2042
The server is operating on battery power - by UPS or backup battery unit (BBU).
TRAP-TYPE    

sc2TrapOnMains 2043
The mains voltage returned after a power failure.
TRAP-TYPE    

sc2TrapVoltageOk 2050
Power supply voltage is within normal range again.
TRAP-TYPE    

sc2TrapVoltageTooLow 2051
Power supply voltage is too low.
TRAP-TYPE    

sc2TrapVoltageTooHigh 2052
Power supply voltage is too high.
TRAP-TYPE    

sc2TrapVoltageFailed 2053
Power supply voltage is out of range.
TRAP-TYPE    

sc2TrapBatteryVoltagePrefail 2054
Battery is predicted to fail
TRAP-TYPE    

sc2TrapCorrectableMemErrorAddr 2060
A correctable memory error at specified address was detected.
TRAP-TYPE    

sc2TrapUncorrectableMemErrorAddr 2061
An uncorrectable memory error at specified address was detected.
TRAP-TYPE    

sc2TrapCorrectableMemErrorBank 2062
A correctable memory error at specified bank was detected.
TRAP-TYPE    

sc2TrapUncorrectableMemErrorBank 2063
An uncorrectable memory error at specified bank was detected.
TRAP-TYPE    

sc2TrapCorrectableMemErrorModule 2064
A correctable memory error at specified module was detected.
TRAP-TYPE    

sc2TrapUncorrectableMemErrorModule 2065
An uncorrectable memory error at specified module was detected.
TRAP-TYPE    

sc2TrapCorrectableMemError 2066
A correctable memory error at unknown location was detected.
TRAP-TYPE    

sc2TrapUncorrectableMemError 2067
An uncorrectable memory error at unknown location was detected.
TRAP-TYPE    

sc2TrapMemErrorModulePrefail 2068
A memory module is predicted to fail (prefailure).
TRAP-TYPE    

sc2TrapMemErrorModuleFailing 2069
A memory module is failing.
TRAP-TYPE    

sc2TrapMemErrorModuleReplaced 2070
A memory module had failed and was replaced by a hot-spare module.
TRAP-TYPE    

sc2TrapMemErrorLoggingDisabled 2071
Too many correctable memory errors; logging disabled.
TRAP-TYPE    

sc2TrapMemErrorLoggingEnabled 2072
Memory errors logging enabled again.
TRAP-TYPE    

sc2TrapMemErrorAnyModuleReplaced 2073
A memory module had failed and was replaced by a hot-spare module.
TRAP-TYPE    

sc2TrapMemErrorRedundancyLost 2074
A memory error caused loss of memory redundancy
TRAP-TYPE    

sc2TrapMemNVDIMMLifetime 2075
An NVDIMM memory module has reached a certain level of lifetime
TRAP-TYPE    

sc2TrapCpuSpeedChanged 2080
This trap will be sent if the CPU clock frequency was changed because of a temperature problem.
TRAP-TYPE    

sc2TrapCpuPrefail 2081
A CPU is predicted to fail (prefailure).
TRAP-TYPE    

sc2TrapCpuIerr 2082
A CPU internal error (IERR) occurred
TRAP-TYPE    

sc2TrapCpuDisabled 2083
A CPU is disabled by BIOS
TRAP-TYPE    

sc2TrapCabinetSwitchedOff 2090
This trap will be sent when a cabinet is switched off. For obvious reasons it cannot be sent when the main cabinet is switched off.
TRAP-TYPE    

sc2TrapCabinetSwitchedOn 2091
This trap will be sent when a cabinet is switched on.
TRAP-TYPE    

sc2TrapPowerOffTimeReached 2092
This trap is sent when the server is going to be switched off by schedule in some minutes.
TRAP-TYPE    

sc2TrapServerShutdown 2093
This trap will be sent when a server is being shut down.
TRAP-TYPE    

sc2TrapShutdownCancelled 2094
This trap will be sent if a pending server shutdown was cancelled by the user.
TRAP-TYPE    

sc2TrapBootRetryCountZero 2095
This trap will be sent when a boot retry counter gets zero on power up.
TRAP-TYPE    

sc2TrapServerBoot 2096
This trap will be sent when the server was booted
TRAP-TYPE    

sc2TrapServerStandby 2097
This trap will be sent when the server entered standby mode
TRAP-TYPE    

sc2TrapServerSuspend 2098
This trap will be sent when the server entered suspend mode
TRAP-TYPE    

sc2TrapServerResumed 2099
This trap will be sent when the server resumed from standby or suspend mode
TRAP-TYPE    

sc2TrapMessageLogFull 2100
The System Event Log (message log) is full. No more messages can be logged. This trap will not occur on wrap-around log types
TRAP-TYPE    

sc2TrapMessageLogWarning 2101
The warning threshold for the number of System Event Log entries has been exceeded.
TRAP-TYPE    

sc2TrapBootMessageLogEntry 2102
An error message was written into the systemboard's message log. This could have happened when an error occured before the server management agents were running or any error without a specific trap. See server management message log for detailed error description.
TRAP-TYPE    

sc2TrapIntrusionAssertion 2110
The front door or housing was opened
TRAP-TYPE    

sc2TrapIntrusionDeassertion 2111
The front door or housing was closed
TRAP-TYPE    

sc2TrapIntrusionChanged 2112
The front door or housing was opened or closed
TRAP-TYPE    

sc2TrapPciBusError 2113
PCI bus system/parity error
TRAP-TYPE    

sc2TrapPowerOnTimeReached 2114
This trap is sent when the server is going to be switched on by schedule in some minutes. It will be sent by the Remote Management Controller.
TRAP-TYPE    

sc2TrapCssWarning 2120
Customer self service component changed to warning status
TRAP-TYPE    

sc2TrapCssFail 2121
Customer self service component changed to fail status
TRAP-TYPE    

sc2TrapCssWarningServer 2122
Customer self service component changed to warning status
TRAP-TYPE    

sc2TrapCssFailServer 2123
Customer self service component changed to fail status
TRAP-TYPE    

sc2TrapPowerLimitOk 2130
Power consumption limit changed to Ok status
TRAP-TYPE    

sc2TrapPowerLimitWarning 2131
Power consumption limit changed to warning status
TRAP-TYPE    

sc2TrapPowerLimitCritical 2132
Power consumption limit changed to critical status
TRAP-TYPE    

sc2TrapPowerLimitDisabled 2133
Power consumption limiting disabled
TRAP-TYPE    

sc2TrapViomInitiateCommunication 2140
VIOM communication initiation request - VIOM manager action required. This trap is intended to signal the Virtual IO Manager that the iRMC wants to confirm the usage of the VIOM table. This trap may be repeated several times until the manager responds to the trap.
TRAP-TYPE    

sc2TrapViomStatusChanged 2141
VIOM status has changed - VIOM manager information. If the user or a server management component deactivates VIOM, the iRMC will send a VIOM status trap. This trap will not be sent if VIOM was activated, because no user interface except the Virtual IO Manager shall be capable to enable VIOM.
TRAP-TYPE    

sc2TrapDrvMonEventMessage 2150
Driver Monitoring detected an informational event.
TRAP-TYPE    

sc2TrapDrvMonEventWarning 2151
Driver Monitoring detected a warning event.
TRAP-TYPE    

sc2TrapDrvMonEventError 2152
Driver Monitoring detected an error event.
TRAP-TYPE