FRX-MIB

File: FRX-MIB.mib (141199 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215

Imported symbols

Counter enterprises Gauge
IpAddress OBJECT-TYPE DisplayString
TRAP-TYPE

Defined Types

NodeBillingTimeEntry  
SEQUENCE    
  downloadTime OCTET STRING
  downloadTimeRowStatus INTEGER
  downloadTimeIndex INTEGER 0..86399

NodeNMSWorkstationEntry  
SEQUENCE    
  nmsWorkstationAddress IpAddress
  nmsWorkstationInetPort INTEGER 0..65535
  nmsWorkstationRowStatus INTEGER

PortConfEntry  
SEQUENCE    
  portConfEntryId INTEGER 0..255
  portConfState INTEGER
  portInterfaceProtocol INTEGER
  portKeepaliveVerif INTEGER
  portBackupInterNodal INTEGER
  portExternalFrTrunk INTEGER
  portUniExternalFrTrunk INTEGER
  portDlciExternalFrTrunk INTEGER 0..1023
  portLinkIntegVerif INTEGER
  portAsyncPVCStatus INTEGER
  portN391Counter INTEGER
  portN392Counter INTEGER
  portN393Counter INTEGER
  portT391Timer INTEGER
  portT392Timer INTEGER
  portSdlcEncapMode INTEGER
  portSdlcEncapDefaultDlci INTEGER 0..1023
  portAddrMapDefaultDlci INTEGER 0..1023
  portPriorityQueuing INTEGER
  portAccountingPerDlci INTEGER
  portPVCOptimization INTEGER

PortStatusEntry  
SEQUENCE    
  portDataBaseState INTEGER
  portTBusState INTEGER
  portUNIState INTEGER
  portNumberEstablishedCircuits INTEGER
  portNumberTotalCircuits INTEGER
  portRxCongestState INTEGER
  portTxCongestState INTEGER
  portAccessRate INTEGER
  portCIR INTEGER
  portNeighbor DisplayString
  portInFrames Counter
  portOutFrames Counter
  portInBytes Counter
  portOutBytes Counter
  portDroppedFrames Counter
  portDroppedDEFrames Counter
  portUnknownDLCIFrames Counter
  portLastUnknownDLCI INTEGER 0..1023
  portDEInFrames Counter
  portDEOutFrames Counter
  portDEInBytes Counter
  portDEOutBytes Counter
  portBECNInFrames Counter
  portBECNOutFrames Counter
  portFECNInFrames Counter
  portFECNOutFrames Counter
  portFrameRateIn Gauge
  portFrameRateOut Gauge
  portByteRateIn Gauge
  portByteRateOut Gauge
  portAverageRxQueue Gauge
  portAverageTxQueue Gauge
  portMaxFrameRateIn Gauge
  portMaxFrameRateOut Gauge
  portMaxByteRateIn Gauge
  portMaxByteRateOut Gauge
  portMaxQueueDepthIn Gauge
  portMaxQueueDepthOut Gauge
  portBadFrames Counter
  portShortFrames Counter
  portMissedFrames Counter
  portLongFrames Counter
  portRxOverruns Counter
  portTxUnderruns Counter
  portStatusEntryId INTEGER
  portStatsClearedTime DisplayString
  portDropBWadmitFrames Counter
  portDropInCongestFrames Counter
  portDropOutCongestFrames Counter
  portDropErroredFrames Counter
  portDropPVCinactiveFrames Counter
  portDropPortDisabledFrames Counter
  portChannelAssignment INTEGER
  portAlarmedPVCs Gauge
  portChannelAssignment30 OCTET STRING

PortSdlcEncapMapEntry  
SEQUENCE    
  addressMapSdlcAddress INTEGER 0..255
  addressMapDlci INTEGER 16..991
  addressMapRowStatus INTEGER
  addressMapPortNumber INTEGER 0..255

CircuitConfEntry  
SEQUENCE    
  circuitSourceAddress DisplayString Size(0..16)
  circuitSourceDLCI INTEGER 0..1023
  circuitDestinationAddress DisplayString Size(0..16)
  circuitDestinationDLCI INTEGER 0..1023
  circuitUserSelectedPath DisplayString Size(0..256)
  circuitAllowAlternatePath INTEGER
  circuitBandwidthAdmission INTEGER
  circuitCommittedInfoRate INTEGER
  circuitBurstSize INTEGER
  circuitExcessBurstSize INTEGER
  circuitPriority INTEGER
  circuitConfState INTEGER
  circuitConfPortNumber INTEGER 0..255
  circuitConfDLCI INTEGER 0..1023

CircuitStatusEntry  
SEQUENCE    
  circuitDataBaseState INTEGER
  circuitState INTEGER
  circuitSetupFailureReason DisplayString
  circuitLastDisconnectReason DisplayString
  circuitRoute DisplayString Size(0..256)
  circuitWindowLength INTEGER
  circuitReceiveFrames Counter
  circuitTransmitFrames Counter
  circuitReceiveBytes Counter
  circuitTransmitBytes Counter
  circuitDroppedFrames Counter
  circuitMarkedDEFrames Counter
  circuitReceivedDEFrames Counter
  circuitCurrentTcBurstBits Counter
  circuitCurrentTcExcessBits Counter
  circuitMaximumBcBits Counter
  circuitMaximumBeBits Counter
  circuitAverageBc Gauge
  circuitAverageBe Gauge
  circuitStatus INTEGER
  circuitDownReason DisplayString
  circuitBECNReceiveFrames Counter
  circuitBECNTransmitFrames Counter
  circuitFECNReceiveFrames Counter
  circuitFECNTransmitFrames Counter
  circuitStatusPortNumber INTEGER 0..255
  circuitStatusDLCI INTEGER 0..1023
  circuitSrcSidePort INTEGER
  circuitSrcSideDLCI INTEGER 0..1023
  circuitDestSidePort INTEGER
  circuitDestSideDLCI INTEGER 0..1023

OperatorTableEntry  
SEQUENCE    
  operatorIndex INTEGER 0..999
  operatorIdentifier DisplayString
  operatorPrivilege INTEGER
  operatorPassword DisplayString
  operatorRowStatus INTEGER

EventTypeEntry  
SEQUENCE    
  eventTypeIndex INTEGER 0..99
  eventTypeLevel INTEGER
  eventTypeDefaultLevel INTEGER
  eventTypeNetworkSignificant INTEGER
  eventTypeDefaultNetworkSignificant INTEGER
  eventTypeForward INTEGER
  eventTypeDefaultForward INTEGER
  eventTypeLog INTEGER
  eventTypeDefaultLog INTEGER
  eventTypeTrap INTEGER
  eventTypeDefaultTrap INTEGER
  eventTypeTrapNumber INTEGER

NetworkTableEntry  
SEQUENCE    
  networkNodeId OCTET STRING
  networkTableIndex INTEGER 0..4294967295
  networkNodeIpAddress IpAddress
  networkNodeNetMask IpAddress

NetworkLinkStateEntry  
SEQUENCE    
  linkStateNeighborId OCTET STRING
  linkStateNodeNumber INTEGER 0..4294967295
  linkStateIndex INTEGER

PortCongestionEntry  
SEQUENCE    
  portCongId INTEGER
  portCongFrameDropRate INTEGER
  portCongUtilThreshold INTEGER
  portCongMinThreshold INTEGER
  portCongDEThreshold INTEGER
  portCongNormalThreshold INTEGER

ClearPVCStatsEntry  
SEQUENCE    
  clearPVCStatsPortId INTEGER 0..7
  clearPVCStatsPvcId INTEGER 16..991
  clearPVCStatsActivator INTEGER

ClearPortStatsEntry  
SEQUENCE    
  clearPortStatsPortId INTEGER
  clearPortStatsActivator INTEGER

TxQueueMaxEntry  
SEQUENCE    
  txQueueMaxPortId INTEGER
  txQueueMax INTEGER
  txQueueMaxRangeMin INTEGER
  txQueueMaxRangeMax INTEGER

PriorityQueuesThresholdEntry  
SEQUENCE    
  thresholdQueuePortId INTEGER
  thresholdQueueId INTEGER
  priorityQueuesThreshold INTEGER
  priorityQueuesThresholdMin INTEGER
  priorityQueuesThresholdMax INTEGER

PriorityQueueRatioEntry  
SEQUENCE    
  priorityQueuePortId INTEGER
  priorityQueueRatio OCTET STRING

GwIPAccessEntry  
SEQUENCE    
  gwIPAccessRowStatus INTEGER
  gwIPAccessAddress IpAddress

Dsx1CurrentEntry  
SEQUENCE    
  dsx1CurrentIndex INTEGER
  dsx1CurrentESs Gauge
  dsx1CurrentSESs Gauge
  dsx1CurrentSEFSs Gauge
  dsx1CurrentUASs Gauge
  dsx1CurrentCSSs Gauge
  dsx1CurrentPCVs Gauge
  dsx1CurrentLESs Gauge
  dsx1CurrentBESs Gauge
  dsx1CurrentDMs Gauge
  dsx1CurrentLCVs Gauge

Dsx1IntervalEntry  
SEQUENCE    
  dsx1IntervalIndex INTEGER
  dsx1IntervalNumber INTEGER
  dsx1IntervalESs Gauge
  dsx1IntervalSESs Gauge
  dsx1IntervalSEFSs Gauge
  dsx1IntervalUASs Gauge
  dsx1IntervalCSSs Gauge
  dsx1IntervalPCVs Gauge
  dsx1IntervalLESs Gauge
  dsx1IntervalBESs Gauge
  dsx1IntervalDMs Gauge
  dsx1IntervalLCVs Gauge

Dsx1TotalEntry  
SEQUENCE    
  dsx1TotalIndex INTEGER
  dsx1TotalESs Gauge
  dsx1TotalSESs Gauge
  dsx1TotalSEFSs Gauge
  dsx1TotalUASs Gauge
  dsx1TotalCSSs Gauge
  dsx1TotalPCVs Gauge
  dsx1TotalLESs Gauge
  dsx1TotalBESs Gauge
  dsx1TotalDMs Gauge
  dsx1TotalLCVs Gauge

Dsx1FarEndCurrentEntry  
SEQUENCE    
  dsx1FarEndCurrentIndex INTEGER
  dsx1FarEndTimeElapsed INTEGER
  dsx1FarEndValidIntervals INTEGER
  dsx1FarEndCurrentESs Gauge
  dsx1FarEndCurrentSESs Gauge
  dsx1FarEndCurrentSEFSs Gauge
  dsx1FarEndCurrentUASs Gauge
  dsx1FarEndCurrentCSSs Gauge
  dsx1FarEndCurrentLESs Gauge
  dsx1FarEndCurrentPCVs Gauge
  dsx1FarEndCurrentBESs Gauge
  dsx1FarEndCurrentDMs Gauge

Dsx1FarEndIntervalEntry  
SEQUENCE    
  dsx1FarEndIntervalIndex INTEGER
  dsx1FarEndIntervalNumber INTEGER
  dsx1FarEndIntervalESs Gauge
  dsx1FarEndIntervalSESs Gauge
  dsx1FarEndIntervalSEFSs Gauge
  dsx1FarEndIntervalUASs Gauge
  dsx1FarEndIntervalCSSs Gauge
  dsx1FarEndIntervalLESs Gauge
  dsx1FarEndIntervalPCVs Gauge
  dsx1FarEndIntervalBESs Gauge
  dsx1FarEndIntervalDMs Gauge

Dsx1FarEndTotalEntry  
SEQUENCE    
  dsx1FarEndTotalIndex INTEGER
  dsx1FarEndTotalESs Gauge
  dsx1FarEndTotalSESs Gauge
  dsx1FarEndTotalSEFSs Gauge
  dsx1FarEndTotalUASs Gauge
  dsx1FarEndTotalCSSs Gauge
  dsx1FarEndTotalLESs Gauge
  dsx1FarEndTotalPCVs Gauge
  dsx1FarEndTotalBESs Gauge
  dsx1FarEndTotalDMs Gauge

Dsx1ChanOwnerEntry  
SEQUENCE    
  dsx1ChanIndex INTEGER
  dsx1ChanOwnerPort INTEGER

Dsx1PortModeEntry  
SEQUENCE    
  dsx1PortMode INTEGER 1..2
  dsx1PortIndex INTEGER 0..255

Defined Values

net 1.3.6.1.4.1.177
OBJECT IDENTIFIER    

spx 1.3.6.1.4.1.177.1
OBJECT IDENTIFIER    

lwx 1.3.6.1.4.1.177.2
OBJECT IDENTIFIER    

frx 1.3.6.1.4.1.177.3
OBJECT IDENTIFIER    

adaptive 1.3.6.1.4.1.177.4
OBJECT IDENTIFIER    

idnx 1.3.6.1.4.1.177.5
OBJECT IDENTIFIER    

globals 1.3.6.1.4.1.177.3.1
OBJECT IDENTIFIER    

node 1.3.6.1.4.1.177.3.2
OBJECT IDENTIFIER    

port 1.3.6.1.4.1.177.3.3
OBJECT IDENTIFIER    

circuit 1.3.6.1.4.1.177.3.4
OBJECT IDENTIFIER    

operator 1.3.6.1.4.1.177.3.5
OBJECT IDENTIFIER    

event 1.3.6.1.4.1.177.3.6
OBJECT IDENTIFIER    

network 1.3.6.1.4.1.177.3.7
OBJECT IDENTIFIER    

management 1.3.6.1.4.1.177.3.8
OBJECT IDENTIFIER    

gateway 1.3.6.1.4.1.177.3.9
OBJECT IDENTIFIER    

dsx 1.3.6.1.4.1.177.3.10
OBJECT IDENTIFIER    

filesystem 1.3.6.1.4.1.177.3.11
OBJECT IDENTIFIER    

mibVersion 1.3.6.1.4.1.177.3.1.1
The version number of this FRX MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibEditVersion 1.3.6.1.4.1.177.3.1.2
The edit version (sub version) number of this FRX MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nodeIdnxAddress 1.3.6.1.4.1.177.3.2.1
The IDNX Address of this PX card, e.g. NxCy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

nodeSoftwareRelease 1.3.6.1.4.1.177.3.2.2
The release of FRX code running on this PX card, e.g. Release 2.01.01 Version 81.01.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

nodeSoftwareReleaseDate 1.3.6.1.4.1.177.3.2.3
The date the FRX code was built, e.g. Wed Feb 10 14:12:24 PST 1993 by tee.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

nodeBootVersion 1.3.6.1.4.1.177.3.2.4
The version of boot prom on the PX card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

nodeCardType 1.3.6.1.4.1.177.3.2.5
The type of PX card running the FRX code.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

nodeUpTime 1.3.6.1.4.1.177.3.2.6
The amount of time the FRX has been alive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

nodeCongestionLevel 1.3.6.1.4.1.177.3.2.7
The current state of congestion for the FRX node. The valid values are notCongested (normal operation), approachingCongestion (FECN and BECN are being set), congested (DE frames are being dropped), and fullyCongested (normal data frames are being dropped).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notCongested(1), approachingCongestion(2), congested(3), fullyCongested(4)  

nodeBuffersUsed 1.3.6.1.4.1.177.3.2.8
The number of system buffers being used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..500  

nodeNumberHDLCPorts 1.3.6.1.4.1.177.3.2.9
The number of HDLC ports the hardware supports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 4..128  

nodeIPAddress 1.3.6.1.4.1.177.3.2.10
The IP Address of this FRX Node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

nodeNetworkMask 1.3.6.1.4.1.177.3.2.11
The IP network mask for this FRX Node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

nodeBackcard 1.3.6.1.4.1.177.3.2.12
Enables or disables the backcard on the FRX node. The backcard must be enabled for gateway functionality. Note: If the backcard is not physically present, an attempt to enable it will result in an error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

nodeBackcardType 1.3.6.1.4.1.177.3.2.13
The type of backcard interface installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet(1), token-ring(2), t1(3), e1(4), t1-ethernet(5), e1-ethernet(6), dual-ethernet(7), ethernet-token-ring(8), quad-t1(9), quad-e1(10), none-unknown-invalid(11)  

nodeBackcardSerialNumber 1.3.6.1.4.1.177.3.2.14
The serial number and revision of the backcard interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..25)  

nodeBillingDownloads 1.3.6.1.4.1.177.3.2.15
Enables or disables billing record downloads to an NMS workstation from this FRX node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

nodeConfigurationDownloads 1.3.6.1.4.1.177.3.2.16
Enables or disables configuration record downloads to an NMS workstation from this FRX node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

nodeFrameCounterThreshold 1.3.6.1.4.1.177.3.2.17
A threshold that causes a billing record to be downloaded when a frame counter exceeds its value.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  INTEGER  

nodeByteCounterThreshold 1.3.6.1.4.1.177.3.2.18
A threshold that causes a billing record to be downloaded when a byte counter exceeds its value.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  INTEGER  

nodeBillingTimeTable 1.3.6.1.4.1.177.3.2.19
The list of times to download billing records to an NMS workstation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NodeBillingTimeEntry

nodeNMSWorkstationTable 1.3.6.1.4.1.177.3.2.20
The list of workstations that are downloaded with billing and configuration records.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NodeNMSWorkstationEntry

nodeNumberTBUSPorts 1.3.6.1.4.1.177.3.2.21
The number of TBus ports the hardware supports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 4..32  

nodeBackcardWanIF 1.3.6.1.4.1.177.3.2.22
Enables or disables the backcard WAN I/F on the FRX node. The backcard must be enabled for WAN port functionality. Note: If the backcard is not physically present, an attempt to enable it will result in an error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

nodeAlarmedPorts 1.3.6.1.4.1.177.3.2.23
The number of front or backcard ports on this node where any of the following conditions is true: - portTBusState (or T1 Status for backcard ports) is 'down' - portUNIState is 'down' - portAlarmedPVCs is not zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

nodeBackcardHardwareAddress 1.3.6.1.4.1.177.3.2.24
The hardware address of the backcard interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..18)  

nodeBillingTimeEntry 1.3.6.1.4.1.177.3.2.19.1
A row from the billing download time table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NodeBillingTimeEntry  

downloadTime 1.3.6.1.4.1.177.3.2.19.1.1
A time of day at which billing records for the node are sent to an NMS workstation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

downloadTimeRowStatus 1.3.6.1.4.1.177.3.2.19.1.2
Controls row deletion for this table. Setting to invalid deletes the row from the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

downloadTimeIndex 1.3.6.1.4.1.177.3.2.19.1.3
The index into the billing time table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..86399  

nodeNMSWorkstationEntry 1.3.6.1.4.1.177.3.2.20.1
A row from the NMS workstation download target list.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NodeNMSWorkstationEntry  

nmsWorkstationAddress 1.3.6.1.4.1.177.3.2.20.1.1
The IP address of an NMS workstation that billing and configuration records get downloaded to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

nmsWorkstationInetPort 1.3.6.1.4.1.177.3.2.20.1.2
The internet port on which the special TFTP server on an NMS workstation will listen for requests to download billing and configuration records.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

nmsWorkstationRowStatus 1.3.6.1.4.1.177.3.2.20.1.3
Controls row deletion for this table. Setting to invalid deletes the row from the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

portConfTable 1.3.6.1.4.1.177.3.3.1
A table of this FRX's port configuration. Before attempting to modify any variables in this table, the port must be disabled (set portConfState = 'disable').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortConfEntry

portConfEntry 1.3.6.1.4.1.177.3.3.1.1
An entry (conceptual row) in the port configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PortConfEntry  

portConfEntryId 1.3.6.1.4.1.177.3.3.1.1.1
The port identifier (number) for this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

portConfState 1.3.6.1.4.1.177.3.3.1.1.2
Performs the enumerated action on the port. That is to say, setting the value to delete will cause the port to be deleted, etc. This variable must be set to 'disable' before any other port configuration variables can be modified.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER delete(1), install(2), disable(3), activate(4)  

portInterfaceProtocol 1.3.6.1.4.1.177.3.3.1.1.3
Determines the function of the port, including which UNI protocol is to be used. All values except interNode are for ports at access points into the network. InterNode is for ports internal to the network. AnsiNetwork, ansiUser, and ansiNNI conform to procedures specified in the ANSI T1.617 Annex D specification. ccittNetwork, ccittUser, and ccittNNI conform to procedures specified in the CCITT Q.933 Annex A specification. lmiNetwork, lmiUser, and lmiNNI conform to procedures specified in the DEC, Northern Telecom, StratCom specification.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ansiNetwork(1), ansiUser(2), ansiNNI(3), ccittNetwork(4), ccittUser(5), ccittNNI(6), lmiNetwork(7), lmiUser(8), none(9), interNode(10), sdlcHdlcEncap(11)  

portKeepaliveVerif 1.3.6.1.4.1.177.3.3.1.1.4
Enables or disables keepalive verification. This parameter is applicable when the portInterfaceProtocol is interNode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

portBackupInterNodal 1.3.6.1.4.1.177.3.3.1.1.5
Enables or disables using this port as a backup Inter-Nodal port. This parameter is applicable when the portInterfaceProtocol is interNode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

portExternalFrTrunk 1.3.6.1.4.1.177.3.3.1.1.6
Enables or disables the External Frame Relay Trunk feature.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

portUniExternalFrTrunk 1.3.6.1.4.1.177.3.3.1.1.7
The UNI protocol to use when the External Frame Relay Trunk feature is enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ansiUser(2), ccittUser(5), lmiUser(8), none(9)  

portDlciExternalFrTrunk 1.3.6.1.4.1.177.3.3.1.1.8
The DLCI of the PVC that is in use at the UNI when the External Frame Relay Trunk feature is enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

portLinkIntegVerif 1.3.6.1.4.1.177.3.3.1.1.9
Determines whether this port will react to problems detected by a UNI protocol. This parameter is applicable if the portInterfaceProtocol is ansi*, ccitt*, or lmi*.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

portAsyncPVCStatus 1.3.6.1.4.1.177.3.3.1.1.10
Determines whether this port should send Asynchronous PVC status messages. This parameter is applicable if the portInterfaceProtocol is ansiNetwork, ansiNNI, ccittNetwork, or ccittNNI.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

portN391Counter 1.3.6.1.4.1.177.3.3.1.1.11
The value for N391, the full status polling counter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

portN392Counter 1.3.6.1.4.1.177.3.3.1.1.12
The value for N392, the error threshold counter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

portN393Counter 1.3.6.1.4.1.177.3.3.1.1.13
The value for N393, the monitored events counter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

portT391Timer 1.3.6.1.4.1.177.3.3.1.1.14
The value for T391, the link integrity polling timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

portT392Timer 1.3.6.1.4.1.177.3.3.1.1.15
The value for T392, the polling verification timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

portSdlcEncapMode 1.3.6.1.4.1.177.3.3.1.1.16
Selects which encapsulation mode to be used when the portInterfacePrococol is sdlcHdlcEncap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER transparent(1), addressMapped(2)  

portSdlcEncapDefaultDlci 1.3.6.1.4.1.177.3.3.1.1.17
Specifies which DLCI will be used to encapsulate received SDLC/HDLC frames at the entry to the network. This parameter is applicable if the portInterfaceProtocol is sdlcHdlcEncap and the encapsulation mode is transparent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

portAddrMapDefaultDlci 1.3.6.1.4.1.177.3.3.1.1.18
Specifies which DLCI will be used to encapsulate received SDLC/HDLC frames at the entry to the network. This parameter is applicable if the portInterfaceProtocol is sdlcHdlcEncap and the encapsulation mode is address-mapped.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..991  

portPriorityQueuing 1.3.6.1.4.1.177.3.3.1.1.19
Enables or disables priority queuing on a port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

portAccountingPerDlci 1.3.6.1.4.1.177.3.3.1.1.20
Enables or disables accounting per DLCI on a port. Enabling this feature may seriously degrade performance in systems with high speed (greater than 1.024 Mbps) ports. Frames may be lost.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

portPVCOptimization 1.3.6.1.4.1.177.3.3.1.1.21
Enables or disables route optimization per DLCI on a port. Enabling this feature may seriously degrade performance in systems with high speed (greater than 1.024 Mbps) ports. Frames may be lost.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

portStatusTable 1.3.6.1.4.1.177.3.3.2
A table of this node's port status and statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortStatusEntry

portStatusEntry 1.3.6.1.4.1.177.3.3.2.1
The port status and statistics table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PortStatusEntry  

portDataBaseState 1.3.6.1.4.1.177.3.3.2.1.1
The state of the port in the database. The values are active and disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER installed(1), active(2)  

portTBusState 1.3.6.1.4.1.177.3.3.2.1.2
The state of the TBus connection for this port. The values are up and down.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2)  

portUNIState 1.3.6.1.4.1.177.3.3.2.1.3
The state of the UNI for this port. The valid values are up and down.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2), invalid(3)  

portNumberEstablishedCircuits 1.3.6.1.4.1.177.3.3.2.1.4
The number of virtual circuits on this port in state Complete.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portNumberTotalCircuits 1.3.6.1.4.1.177.3.3.2.1.5
The total number of virtual circuits on this port, regardles of state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portRxCongestState 1.3.6.1.4.1.177.3.3.2.1.6
The congestion state of the port's receiver. The valid values are notCongested (normal operation), approachingCongestion (FECN and BECN are being set), congested (DE frames are being dropped), and fullyCongested (normal data frames are being dropped).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notCongested(1), approachingCongestion(2), congested(3), fullyCongested(4)  

portTxCongestState 1.3.6.1.4.1.177.3.3.2.1.7
The congestion state of the port's transmitter. The valid values are notCongested (normal operation), approachingCongestion (FECN and BECN are being set), congested (DE frames are being dropped), and fullyCongested (normal data frames are being dropped).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notCongested(1), approachingCongestion(2), congested(3), fullyCongested(4)  

portAccessRate 1.3.6.1.4.1.177.3.3.2.1.8
The access rate (speed) for this port in bits per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portCIR 1.3.6.1.4.1.177.3.3.2.1.9
The total allocated committed information rate for all virtual circuits on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portNeighbor 1.3.6.1.4.1.177.3.3.2.1.10
Represents the IDNX domain-node-card of the adjacent FRX. This field is valid for ports with the interface protocol set to interNode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

portInFrames 1.3.6.1.4.1.177.3.3.2.1.11
The number of frames received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portOutFrames 1.3.6.1.4.1.177.3.3.2.1.12
The number of frames transmitter by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portInBytes 1.3.6.1.4.1.177.3.3.2.1.13
The number of bytes received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portOutBytes 1.3.6.1.4.1.177.3.3.2.1.14
The number of bytes transmitted by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDroppedFrames 1.3.6.1.4.1.177.3.3.2.1.15
The number of frames dropped by the port for reasons other than: DE, unknown DLCI, bandwidth admission, input/output congestion, frame error, inactive PVC, or disabled port. These are generally internal errors, such as 'Heap buffer failed'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDroppedDEFrames 1.3.6.1.4.1.177.3.3.2.1.16
The number of frames with DE set dropped due to congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portUnknownDLCIFrames 1.3.6.1.4.1.177.3.3.2.1.17
The number of frames received with unknown DLCIs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portLastUnknownDLCI 1.3.6.1.4.1.177.3.3.2.1.18
The DLCI number of the last frame with an unknown DLCI. A value of -1 signifies that no unknown DLCI has yet been received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

portDEInFrames 1.3.6.1.4.1.177.3.3.2.1.19
The number of DE frames received by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDEOutFrames 1.3.6.1.4.1.177.3.3.2.1.20
The number of DE frames transmitted by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDEInBytes 1.3.6.1.4.1.177.3.3.2.1.21
The number of bytes received in DE frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDEOutBytes 1.3.6.1.4.1.177.3.3.2.1.22
The number of bytes transmitted in DE frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portBECNInFrames 1.3.6.1.4.1.177.3.3.2.1.23
The number of BECN frames received by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portBECNOutFrames 1.3.6.1.4.1.177.3.3.2.1.24
The number BECN frames transmitted by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portFECNInFrames 1.3.6.1.4.1.177.3.3.2.1.25
The number of FECN frames received by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portFECNOutFrames 1.3.6.1.4.1.177.3.3.2.1.26
The number of FECN frames transmitted by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portFrameRateIn 1.3.6.1.4.1.177.3.3.2.1.27
The rate in frames per second of frames received by the FRX. This number is a updated every minute and represents the last five minutes worth of traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portFrameRateOut 1.3.6.1.4.1.177.3.3.2.1.28
The rate in frames per second of frames transmitted by the FRX. This number is a updated every minute and represents the last five minutes worth of traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portByteRateIn 1.3.6.1.4.1.177.3.3.2.1.29
The rate in bytes per second received by the FRX. This number is updated every minute and represents the last five minutes worth of traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portByteRateOut 1.3.6.1.4.1.177.3.3.2.1.30
The rate in bytes per second received by the FRX. This number is updated every minute and represents the last five minutes worth of traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portAverageRxQueue 1.3.6.1.4.1.177.3.3.2.1.31
The average depth of the receiver's input queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portAverageTxQueue 1.3.6.1.4.1.177.3.3.2.1.32
The average depth of the transmitter's output queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portMaxFrameRateIn 1.3.6.1.4.1.177.3.3.2.1.33
The maximum frame rate for frames received by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portMaxFrameRateOut 1.3.6.1.4.1.177.3.3.2.1.34
The maximum frame rate for frames transmitted by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portMaxByteRateIn 1.3.6.1.4.1.177.3.3.2.1.35
The maximum byte rate for frames received by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portMaxByteRateOut 1.3.6.1.4.1.177.3.3.2.1.36
The maximum byte rate for frames transmitted by a port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portMaxQueueDepthIn 1.3.6.1.4.1.177.3.3.2.1.37
The maximum length of a port's receive queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portMaxQueueDepthOut 1.3.6.1.4.1.177.3.3.2.1.38
The maximum length of a port's transmit queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portBadFrames 1.3.6.1.4.1.177.3.3.2.1.39
The number of frames dropped by the HDLC controller. Examples of reasons why frames are dropped include receiving a bad CRC and non-octet alignment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portShortFrames 1.3.6.1.4.1.177.3.3.2.1.40
The number of frames received by the HDLC controller that don't meet the minimum length restriction.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portMissedFrames 1.3.6.1.4.1.177.3.3.2.1.41
The number of receive frames missed by the HDLC controller. This happens when the receiver's input queue is full.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portLongFrames 1.3.6.1.4.1.177.3.3.2.1.42
The number of frames received longer than the maximum length.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portRxOverruns 1.3.6.1.4.1.177.3.3.2.1.43
The number of receiver overruns the HDLC controller experiences.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portTxUnderruns 1.3.6.1.4.1.177.3.3.2.1.44
The number of transmitter underruns the HDLC controller experiences.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portStatusEntryId 1.3.6.1.4.1.177.3.3.2.1.45
The port identifier (number) for this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

portStatsClearedTime 1.3.6.1.4.1.177.3.3.2.1.46
The amount of time since the last time the statistics were cleared for this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

portDropBWadmitFrames 1.3.6.1.4.1.177.3.3.2.1.47
The number of frames dropped due to Bandwidth Admission enforcement at the port. This occurs when the number of frames is greater than (Bc + Be) during Tc over all Tc's since the last clear of statistics. In other words, these are the burst frames which exceed the sum of the Committed Burst size (Bc) and the Excess Burst size (Be) over each time interval (Tc). This count is only valid when Bandwidth Admission is Enabled for the port; otherwise, it is zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDropInCongestFrames 1.3.6.1.4.1.177.3.3.2.1.48
The number of frames dropped because the port input buffer is fully congested.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDropOutCongestFrames 1.3.6.1.4.1.177.3.3.2.1.49
The number of frames dropped because the port output buffer is fully congested.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDropErroredFrames 1.3.6.1.4.1.177.3.3.2.1.50
The number of frames dropped because of frame errors. These include: bad DLCI, invalid DLCI (with and without Cache), invalid source route frame, and wierd frame.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDropPVCinactiveFrames 1.3.6.1.4.1.177.3.3.2.1.51
The number of frames dropped because the PVC is inactive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDropPortDisabledFrames 1.3.6.1.4.1.177.3.3.2.1.52
The number of frames dropped because the port is Disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portChannelAssignment 1.3.6.1.4.1.177.3.3.2.1.53
This variable will not be available from version 3.0 onwards; it has been replaced by portChannelAssignment30 (see below).
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

portAlarmedPVCs 1.3.6.1.4.1.177.3.3.2.1.54
The number of circuits on this port where all of the following conditions are true: - circuitState is not 'idle' - circuitStatus is not 'active'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

portChannelAssignment30 1.3.6.1.4.1.177.3.3.2.1.55
The DS0s assigned to this logical backcard port. These may, or may not, be contiguous (when more than one is assigned).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

portSdlcEncapMapTable 1.3.6.1.4.1.177.3.3.3
The table containing address map translations between DLCIs and SDLC/HDLC addresses. This table is applicable if the portInterfaceProtocol is sdlcHdlcEncap and the portSdlcEncapMode is addressMapped.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortSdlcEncapMapEntry

portSdlcEncapMapEntry 1.3.6.1.4.1.177.3.3.3.1
A row from the address map translation table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PortSdlcEncapMapEntry  

addressMapSdlcAddress 1.3.6.1.4.1.177.3.3.3.1.1
The SDLC or HDLC address that is mapped to a DLCI when using SDLC/HDLC encapsulation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

addressMapDlci 1.3.6.1.4.1.177.3.3.3.1.2
The DLCI used when mapping an SCLC/HDLC address when SLDC/HDLC encapsulation is being used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

addressMapRowStatus 1.3.6.1.4.1.177.3.3.3.1.3
Used to create a row in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

addressMapPortNumber 1.3.6.1.4.1.177.3.3.3.1.4
The port number index for the address map table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

circuitConfTable 1.3.6.1.4.1.177.3.4.1
A table containing configuration information for a circuit. The objects in this table are always readable; they can only be written (if accessible) only for the instance in which the circuitConfPortNumber and circuitConfDLCI correspond to the port number and DLCI at the source (originate). When creating a new circuit, at a minimum the destination address must be supplied. Note: Before modifying any circuit configuration variables, the circuit must be disabled (set circuitConfState = 'disable').
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CircuitConfEntry

circuitConfEntry 1.3.6.1.4.1.177.3.4.1.1
Configuration information about a particular circuit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CircuitConfEntry  

circuitSourceAddress 1.3.6.1.4.1.177.3.4.1.1.1
The value of this object is the source (originate) address of this circuit. It is expressed in terms of IDNX Node, Card, and Port (NxCyPz).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

circuitSourceDLCI 1.3.6.1.4.1.177.3.4.1.1.2
The value of this object is the DLCI associated with the source address of this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

circuitDestinationAddress 1.3.6.1.4.1.177.3.4.1.1.3
The value of this object is the destination (termination) address of this circuit. The value must be consistent with the endpoint of the user-selected path (if one exists). In the case of a manager that can issue only single-varbind Set requests, clear the user-selected path (if one exists) before attempting to change this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

circuitDestinationDLCI 1.3.6.1.4.1.177.3.4.1.1.4
The value of this object is the DLCI associated with the destination address of this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..991  

circuitUserSelectedPath 1.3.6.1.4.1.177.3.4.1.1.5
The value of this object is the required path through the FRX network that this virtual circuit must take. The endpoints of this path must be consistent with the configured source and destination addresses. The value 'disabled' indicates that a user-selected path has not been configured.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..256)  

circuitAllowAlternatePath 1.3.6.1.4.1.177.3.4.1.1.6
If a user-selected path has been configured, enabling this variable allows the FRX to choose an alternate route through the network if the user-selected path is unavailable. Disabling it forces the FRX to wait until the user-selected path is available before establishing the PVC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

circuitBandwidthAdmission 1.3.6.1.4.1.177.3.4.1.1.7
The field reflects the status of bandwidth admission for this virtual circuit. If enabled then CIR, Be, and Bc must be configured.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

circuitCommittedInfoRate 1.3.6.1.4.1.177.3.4.1.1.8
The committed information rate (in bits per second) for this virtual circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

circuitBurstSize 1.3.6.1.4.1.177.3.4.1.1.9
The burst size (Bc, expressed in bits) for this virtual circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

circuitExcessBurstSize 1.3.6.1.4.1.177.3.4.1.1.10
The excess burst size (Be, expressed in bits) for this virtual circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

circuitPriority 1.3.6.1.4.1.177.3.4.1.1.11
The priority value of this circuit. If prioritized circuits are not enabled on the port then the circuit priority is set to (normal); normal priority is always one less than the highest priority available, which depend on the number of priority queues defined. There can between 2, and 15 priority queues defined. The default is 3. This parameter can not be set unless Prioritize PVC is enabled for the port (portPriorityQueueing).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pri-1(1), pri-2(2), pri-3(3), pri-4(4), pri-5(5), pri-6(6), pri-7(7), pri-8(8), pri-9(9), pri-10(10), pri-11(11), pri-12(12), pri-13(13), pri-14(14), pri-15(15)  

circuitConfState 1.3.6.1.4.1.177.3.4.1.1.12
The database state for this virtual circuit. Setting this field to delete causes the virtual circuit to be deleted. Setting this field to install either creates a new circuit, or disables an already existing circuit. Activating the circuit builds the circuit across the network. Note: The database state must be set to 'disable' before any other circuit parameters can be modified.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER delete(1), install(2), disable(3), activate(4)  

circuitConfPortNumber 1.3.6.1.4.1.177.3.4.1.1.13
The first index into the circuit configuration table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

circuitConfDLCI 1.3.6.1.4.1.177.3.4.1.1.14
The second index into the circuit configuration table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

circuitStatusTable 1.3.6.1.4.1.177.3.4.2
A table containing virtual circuit status for this port
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CircuitStatusEntry

circuitStatusEntry 1.3.6.1.4.1.177.3.4.2.1
A status entry contains information about virtual circuits.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CircuitStatusEntry  

circuitDataBaseState 1.3.6.1.4.1.177.3.4.2.1.1
The value of this object identifies the current database state of the PVC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER installed(1), active(2)  

circuitState 1.3.6.1.4.1.177.3.4.2.1.2
This field represents the status of the virtual circuit. The possible values for the state are idle, setup, complete, and disconnect.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), setup(2), complete(3), disconnect(4)  

circuitSetupFailureReason 1.3.6.1.4.1.177.3.4.2.1.3
This field is valid when the call cannot be completed. The reason the circuit setup failed is contained in this string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

circuitLastDisconnectReason 1.3.6.1.4.1.177.3.4.2.1.4
This field displays the reason for the last disconnect of this virtual circuit, including normal termination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

circuitRoute 1.3.6.1.4.1.177.3.4.2.1.5
This field displays the route that the circuit has taken through the FRX network. It is expressed in terms of IDNX Nodes and Cards (NxCy-NxCy-[...]NxCy.)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..256)  

circuitWindowLength 1.3.6.1.4.1.177.3.4.2.1.6
The value of this object is the window length (Tc) used for bandwidth admission procedures. The units are tenths-of-seconds. This object is applicable only if bandwidth admission is enabled for the circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

circuitReceiveFrames 1.3.6.1.4.1.177.3.4.2.1.7
The number of frames received by this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitTransmitFrames 1.3.6.1.4.1.177.3.4.2.1.8
The number of frames transmitted by this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitReceiveBytes 1.3.6.1.4.1.177.3.4.2.1.9
The number of bytes received by this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitTransmitBytes 1.3.6.1.4.1.177.3.4.2.1.10
The number of bytes transmitted by this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitDroppedFrames 1.3.6.1.4.1.177.3.4.2.1.11
This field represents the number of frames dropped for this DLCI due to bandwidth admission procedures.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitMarkedDEFrames 1.3.6.1.4.1.177.3.4.2.1.12
This field represents the number of frames in which the FRX set the DE bit, due to bandwidth admission procedures.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitReceivedDEFrames 1.3.6.1.4.1.177.3.4.2.1.13
This field represents the number of frames received with the DE bit set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitCurrentTcBurstBits 1.3.6.1.4.1.177.3.4.2.1.14
The number of Bc bits received during the present Tc window.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitCurrentTcExcessBits 1.3.6.1.4.1.177.3.4.2.1.15
The number of Be bits received during the present Tc window.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitMaximumBcBits 1.3.6.1.4.1.177.3.4.2.1.16
The maximum number of Bc bits received for this virtual circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitMaximumBeBits 1.3.6.1.4.1.177.3.4.2.1.17
The maximum number of Be bits received for this virtual circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitAverageBc 1.3.6.1.4.1.177.3.4.2.1.18
The average number of Bc bits during the past five (5) Tc periods.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

circuitAverageBe 1.3.6.1.4.1.177.3.4.2.1.19
The average number of Be bits during the past five (5) Tc periods.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

circuitStatus 1.3.6.1.4.1.177.3.4.2.1.20
The status of virtual circuit. The valid values are Active or Inactive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

circuitDownReason 1.3.6.1.4.1.177.3.4.2.1.21
This field is a description of why the virtual circuit is down.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

circuitBECNReceiveFrames 1.3.6.1.4.1.177.3.4.2.1.22
The number of BECN frames received by the circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitBECNTransmitFrames 1.3.6.1.4.1.177.3.4.2.1.23
The number of BECN frames transmitted by the circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitFECNReceiveFrames 1.3.6.1.4.1.177.3.4.2.1.24
The number of FECN frames received by the circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitFECNTransmitFrames 1.3.6.1.4.1.177.3.4.2.1.25
The number of FECN frames transmitted by the circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

circuitStatusPortNumber 1.3.6.1.4.1.177.3.4.2.1.26
The first index into the circuit table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

circuitStatusDLCI 1.3.6.1.4.1.177.3.4.2.1.27
The second index into the circuit table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

circuitSrcSidePort 1.3.6.1.4.1.177.3.4.2.1.28
A circuit segment within an FRX node has two endpoints, each identified by a (port,DLCI) pair. This variable is the source side port number. Note: A value of -1 means 'not applicable'. This variable is not applicable unless the PVC state is Complete.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

circuitSrcSideDLCI 1.3.6.1.4.1.177.3.4.2.1.29
A circuit segment within an FRX node has two endpoints, each identified by a (port,DLCI) pair. This variable is the source side DLCI. Note: A value of -1 means 'not applicable'. This variable is not applicable unless the PVC state is Complete.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

circuitDestSidePort 1.3.6.1.4.1.177.3.4.2.1.30
A circuit segment within an FRX node has two endpoints, each identified by a (port,DLCI) pair. This variable is the destination side port number. Note: A value of -1 means 'not applicable'. This variable is not applicable unless the PVC state is Complete.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

circuitDestSideDLCI 1.3.6.1.4.1.177.3.4.2.1.31
A circuit segment within an FRX node has two endpoints, each identified by a (port,DLCI) pair. This variable is the destination side DLCI. Note: A value of -1 means 'not applicable'. This variable is not applicable unless the PVC state is Complete.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

operatorCount 1.3.6.1.4.1.177.3.5.1
The number of operators currently installed on this FRX.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

operatorTable 1.3.6.1.4.1.177.3.5.2
The list of operators installed on this FRX. A row can be added to this table using a set request that includes, at minimum, a valid value for operatorIdentifier. A row can be deleted by setting operatorRowStatus to invalid.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OperatorTableEntry

operatorTableEntry 1.3.6.1.4.1.177.3.5.2.1
An entry (conceptual row) in the operator table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OperatorTableEntry  

operatorIndex 1.3.6.1.4.1.177.3.5.2.1.1
The auxiliary variable used for identifying instances of the columnar objects in the operator table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

operatorIdentifier 1.3.6.1.4.1.177.3.5.2.1.2
A textual string giving the name of this operator. Cannot be empty. A name for a new operator cannot duplicate a name for an existing operator. There is no default value, so a valid value for this column must be includedin any set request for row creation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

operatorPrivilege 1.3.6.1.4.1.177.3.5.2.1.3
The privilege level for this operator.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER queryOnly(1), any(2)  

operatorPassword 1.3.6.1.4.1.177.3.5.2.1.4
The password for this operator. Can be empty.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

operatorRowStatus 1.3.6.1.4.1.177.3.5.2.1.5
Setting this column to invalid will delete this operator. Setting it to valid has no effect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

eventTypeTable 1.3.6.1.4.1.177.3.6.1
A table listing the types of real-time events on the FRX. The event types comprise two main categories: configuration changes (PVC installed, port activated, etc.), and status changes (port congested, node decongested, etc.). Though the types of events are static, some of their attributes, such as whether or not they trigger an SNMP trap, are configurable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EventTypeEntry

eventTypeEntry 1.3.6.1.4.1.177.3.6.1.1
Information about a particular event on the FRX. The event types comprise two main categories: configuration changes (PVC installed, port activated, etc.), and status changes (port congested, node decongested, etc.). Though the types of events are static, some of their attributes, such as whether or not they trigger an SNMP trap, are configurable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EventTypeEntry  

eventTypeIndex 1.3.6.1.4.1.177.3.6.1.1.1
Auxiliary variable used to identify row instances in the eventTypeTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

eventTypeLevel 1.3.6.1.4.1.177.3.6.1.1.2
The IDNX alarm level of this FRX event; user configurable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAlarm(1), fyiAlarm(2), minorAlarm(3), majorAlarm(4), criticalAlarm(5)  

eventTypeDefaultLevel 1.3.6.1.4.1.177.3.6.1.1.3
The default IDNX alarm level of this FRX event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), fyiAlarm(2), minorAlarm(3), majorAlarm(4), criticalAlarm(5)  

eventTypeNetworkSignificant 1.3.6.1.4.1.177.3.6.1.1.4
Determines whether or not this type of event is forwarded to the repository node for network-significant events.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

eventTypeDefaultNetworkSignificant 1.3.6.1.4.1.177.3.6.1.1.5
Default determination of whether or not this type of event is forwarded to the repository node for network-significant events.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

eventTypeForward 1.3.6.1.4.1.177.3.6.1.1.6
Determines whether or not this type of event is forwarded to the IDNX event log; user configurable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

eventTypeDefaultForward 1.3.6.1.4.1.177.3.6.1.1.7
Default determination of whether or not this type of event is forwarded to the IDNX event log.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

eventTypeLog 1.3.6.1.4.1.177.3.6.1.1.8
Determines whether or not this type of event is logged to the FRX (local) event log; user configurable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

eventTypeDefaultLog 1.3.6.1.4.1.177.3.6.1.1.9
Default determination of whether or not this type of event is logged to the FRX (local) event log.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

eventTypeTrap 1.3.6.1.4.1.177.3.6.1.1.10
Determines whether or not this type of event generates an SNMP trap; user configurable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

eventTypeDefaultTrap 1.3.6.1.4.1.177.3.6.1.1.11
Default determination of whether or not this type of event generates an SNMP trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

eventTypeTrapNumber 1.3.6.1.4.1.177.3.6.1.1.12
Enterprise-specific trap number associated with this event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER systemRestartTrap(1), systemSyserrTrap(2), configChangedTrap(3), nodeCongestedTrap(4), portInstalledTrap(5), portDeletedTrap(6), portActivatedTrap(7), portDisabledTrap(8), portCongestedTrap(9), pvcInstalledTrap(10), pvcDeletedTrap(11), pvcActivatedTrap(12), pvcDisabledTrap(13), pvcStatusActiveTrap(14), pvcStatusInactiveTrap(15), cbusUpTrap(16), cbusDownTrap(17), serialFailTrap(18), portUniActiveTrap(19), portUniInactiveTrap(20), portIDNXCallUpTrap(21), portIDNXCallDownTrap(22), nodeNotCongestedTrap(23), portNotCongestedTrap(24), operatorResetTrap(25), eventLogClearedTrap(26), configClearedTrap(27), functionMismatchTrap(28), eventLogErrorTrap(29), encapActiveTrap(30), encapInactiveTrap(31), altPathUsedTrap(32), pvcStateIdleTrap(33), pvcStateSetupTrap(34), pvcStateCompleteTrap(35), pvcStateDisconnectTrap(36), billingDownloadSuccessTrap(37), billingDownloadFailureTrap(38), billingDownloadThresholdTrap(39), configSyntaxErrorTrap(40), configDownloadSuccessTrap(41), configDownloadFailureTrap(42), nodeFlashMemErr(50), nodeFlashWriteErr(51), nodeUserLogin(52), nodeUserLogout(53), dsx1NoAlarm(54), dsx1RcvFarEndLOF(55), dsx1RcvFarEndLOFEnded(56), dsx1XmtFarEndLOF(57), dsx1XmtFarEndLOFEnding(58), dsx1RcvAIS(59), dsx1RcvAISEnded(60), dsx1XmtAIS(61), dsx1XmtAISEnding(62), dsx1LossOfFrame(63), dsx1LossOfFrameEnded(64), dsx1LossOfSignal(65), dsx1LossOfSignalEnded(66), dsx1LoopbackState(67), dsx1LoopbackStateEnded(68), dsx1T16AIS(69), dsx1T16AISEnded(70), dsx1RcvFarEndLOMF(71), dsx1RcvFarEndLOMFEnded(72), dsx1XmtFarEndLOMF(73), dsx1XmtFarEndLOMFEnding(74), dsx1RcvTestCode(75), dsx1OtherFailure(76), nodeAlarmedPortsZero(77), portAlarmedPVCsZero(78), operatorInstallTrap(79), operatorDeleteTrap(80), portPVCReOptimizationStart(81), portPVCReOptimizationEnd(82)  

networkNodeCount 1.3.6.1.4.1.177.3.7.1
The number of nodes this FRX knows about in the FRX network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

networkTable 1.3.6.1.4.1.177.3.7.2
The network table contains information on FRX nodes that is known network wide. This information is distributed via a link state algorithm.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NetworkTableEntry

networkLinkStateTable 1.3.6.1.4.1.177.3.7.3
The link state table is a list of FRX nodes that are neighbors to a given FRX node.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NetworkLinkStateEntry

networkTableEntry 1.3.6.1.4.1.177.3.7.2.1
A row in the network table. Each row contains information on a different node in the network.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NetworkTableEntry  

networkNodeId 1.3.6.1.4.1.177.3.7.2.1.1
The IDNX domain-node-card address of the FRX node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

networkTableIndex 1.3.6.1.4.1.177.3.7.2.1.2
The index for a particular row in the network table. The value of this index is the FRX node number that corresponds to the networkNodeId address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

networkNodeIpAddress 1.3.6.1.4.1.177.3.7.2.1.3
The IP address of the FRX node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

networkNodeNetMask 1.3.6.1.4.1.177.3.7.2.1.4
The network mask of the FRX node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

networkLinkStateEntry 1.3.6.1.4.1.177.3.7.3.1
A row in the link state table. Each row contains information on the neighbor nodes for the FRX node in the network table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NetworkLinkStateEntry  

linkStateNeighborId 1.3.6.1.4.1.177.3.7.3.1.1
The IDNX domain-node-card address of a neighbor FRX node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

linkStateNodeNumber 1.3.6.1.4.1.177.3.7.3.1.2
The first index into the link state table. The value of this index is an FRX node number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4294967295  

linkStateIndex 1.3.6.1.4.1.177.3.7.3.1.3
The second index into the link state table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

bufferCongestion 1.3.6.1.4.1.177.3.8.1
OBJECT IDENTIFIER    

portCongestion 1.3.6.1.4.1.177.3.8.2
OBJECT IDENTIFIER    

routingParameters 1.3.6.1.4.1.177.3.8.3
OBJECT IDENTIFIER    

clearObjects 1.3.6.1.4.1.177.3.8.4
OBJECT IDENTIFIER    

saveConfiguration 1.3.6.1.4.1.177.3.8.5
OBJECT IDENTIFIER    

nmsDownloads 1.3.6.1.4.1.177.3.8.6
OBJECT IDENTIFIER    

portQueueThreshold 1.3.6.1.4.1.177.3.8.7
OBJECT IDENTIFIER    

priorityQueues 1.3.6.1.4.1.177.3.8.8
OBJECT IDENTIFIER    

bufferMinimumThreshold 1.3.6.1.4.1.177.3.8.1.1
The minimum percentage of buffer utilization to cause node congestion.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

bufferDEFrameThreshold 1.3.6.1.4.1.177.3.8.1.2
The minimum percentage of buffer utilization that causes DE frames to be dropped.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

bufferNormalFrameThreshold 1.3.6.1.4.1.177.3.8.1.3
The minimum percentage of buffer utilization that causes normal data frames to be dropped.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

portCongestionTable 1.3.6.1.4.1.177.3.8.2.1
A list of the port congestion parameters, row for each port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortCongestionEntry

portCongestionEntry 1.3.6.1.4.1.177.3.8.2.1.1
A row from the port congestion parameters table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PortCongestionEntry  

portCongId 1.3.6.1.4.1.177.3.8.2.1.1.1
The port number associated with this row in the table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portCongFrameDropRate 1.3.6.1.4.1.177.3.8.2.1.1.2
The rate at which normal frames are dropped during extreme congestion.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

portCongUtilThreshold 1.3.6.1.4.1.177.3.8.2.1.1.3
The percentage of the port's access rate, at which time congestion avoidance procedures are started.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..100  

portCongMinThreshold 1.3.6.1.4.1.177.3.8.2.1.1.4
The number of seconds of port congestion before FECN and BECN begin to get set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

portCongDEThreshold 1.3.6.1.4.1.177.3.8.2.1.1.5
The number of seconds of APPROACHINGCONGESTION before DE frames begin to get dropped.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

portCongNormalThreshold 1.3.6.1.4.1.177.3.8.2.1.1.6
The number of seconds of DECONGESTION before normal data frames begin to get dropped.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

routingLongTimeout 1.3.6.1.4.1.177.3.8.3.1
The amount of time between normal routing table updates for this FRX node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 10..600  

routingShortTimeout 1.3.6.1.4.1.177.3.8.3.2
The amount of time to wait after a PVC has been added or deleted before distributing a new routing table update for this FRX node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..30  

routingCriticalStaleness 1.3.6.1.4.1.177.3.8.3.3
The number of minor changes or short timeouts that causes a routing table update to be distributed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

clearEventLog 1.3.6.1.4.1.177.3.8.4.1
OBJECT IDENTIFIER    

clearPVCStats 1.3.6.1.4.1.177.3.8.4.2
OBJECT IDENTIFIER    

clearPortStats 1.3.6.1.4.1.177.3.8.4.3
OBJECT IDENTIFIER    

clearConfiguration 1.3.6.1.4.1.177.3.8.4.4
OBJECT IDENTIFIER    

eventLogClear 1.3.6.1.4.1.177.3.8.4.1.1
Writing to this object will cause the event log to be cleared.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

clearPVCStatsTable 1.3.6.1.4.1.177.3.8.4.2.1
A virtual table which is used to clear PVC statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ClearPVCStatsEntry

clearPVCStatsEntry 1.3.6.1.4.1.177.3.8.4.2.1.1
A row of parameters which are used to clear PVC based statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ClearPVCStatsEntry  

clearPVCStatsPortId 1.3.6.1.4.1.177.3.8.4.2.1.1.1
The port number identifying a PVC whose statistics are to be cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

clearPVCStatsPvcId 1.3.6.1.4.1.177.3.8.4.2.1.1.2
The DLCI value identifying a PVC whose statistics are to be cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..991  

clearPVCStatsActivator 1.3.6.1.4.1.177.3.8.4.2.1.1.3
After setting up the clearPVCStatsPVCId and clearPVCStatsPortId fields, writing to this field will clear the identified PVCs counters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

clearPortStatsTable 1.3.6.1.4.1.177.3.8.4.3.1
A virtual table for clearing port based statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ClearPortStatsEntry

clearPortStatsEntry 1.3.6.1.4.1.177.3.8.4.3.1.1
A virtual entry used to clear port statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ClearPortStatsEntry  

clearPortStatsPortId 1.3.6.1.4.1.177.3.8.4.3.1.1.1
Setting the field to a valid port number and then writing to clearPortStatsActivator will clear a port's statistics.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

clearPortStatsActivator 1.3.6.1.4.1.177.3.8.4.3.1.1.2
After setting the clearPortStatsPortId field with a valid port number, writing to this field will clear a port's statistics.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

configurationClear 1.3.6.1.4.1.177.3.8.4.4.1
Writing anything to this field will clear a FRX node's configuration. This can be very dangerous.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

configurationSave 1.3.6.1.4.1.177.3.8.5.1
Writing anything to this field will cause the current configuration to be saved in the non-volatile store of the PX card.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fullConfigDownload 1.3.6.1.4.1.177.3.8.6.1
Writing anything to this field will cause the current PVC configuration to be downloaded to a NMS workstation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

txQueueMaxTable 1.3.6.1.4.1.177.3.8.7.1
A list of the port transmit queue maximum size, row for each port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TxQueueMaxEntry

txQueueMaxEntry 1.3.6.1.4.1.177.3.8.7.1.1
A row from the port transmit queue max size table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TxQueueMaxEntry  

txQueueMaxPortId 1.3.6.1.4.1.177.3.8.7.1.1.1
The port number associated with this row in the table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

txQueueMax 1.3.6.1.4.1.177.3.8.7.1.1.2
The Transmit Queue Max size for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..256  

txQueueMaxRangeMin 1.3.6.1.4.1.177.3.8.7.1.1.3
Transmit Queue Max size range minimum value for this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

txQueueMaxRangeMax 1.3.6.1.4.1.177.3.8.7.1.1.4
Transmit Queue Max size range maximum value for this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

priorityQueuesThresholdTable 1.3.6.1.4.1.177.3.8.7.2
A list of the port priority queues threshold, row for each port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PriorityQueuesThresholdEntry

priorityQueuesThresholdEntry 1.3.6.1.4.1.177.3.8.7.2.1
A row from the port priority queues threshold table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PriorityQueuesThresholdEntry  

thresholdQueuePortId 1.3.6.1.4.1.177.3.8.7.2.1.1
The port number associated with this row in the table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

thresholdQueueId 1.3.6.1.4.1.177.3.8.7.2.1.2
The queue associated with this row in the table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..5  

priorityQueuesThreshold 1.3.6.1.4.1.177.3.8.7.2.1.3
Priority Queue threshold for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..256  

priorityQueuesThresholdMin 1.3.6.1.4.1.177.3.8.7.2.1.4
Minimum Priority Queue threshold for this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

priorityQueuesThresholdMax 1.3.6.1.4.1.177.3.8.7.2.1.5
Maximum Priority Queue threshold for this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

numberOfPriorities 1.3.6.1.4.1.177.3.8.8.1
The number of priorities for a given node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 2..5  

priorityQueueRatioTable 1.3.6.1.4.1.177.3.8.8.2
A list of the port priority queues ratios, row for each port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PriorityQueueRatioEntry

priorityQueueRatioEntry 1.3.6.1.4.1.177.3.8.8.2.1
A row from the port priority queues ratio table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PriorityQueueRatioEntry  

priorityQueuePortId 1.3.6.1.4.1.177.3.8.8.2.1.1
The port number associated with this row in the table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

priorityQueueRatio 1.3.6.1.4.1.177.3.8.8.2.1.2
Priority Queue ratio for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

gwIPAddress 1.3.6.1.4.1.177.3.9.1
The IP Address of the FRX backcard.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

gwNetMask 1.3.6.1.4.1.177.3.9.2
The network mask of the FRX backcard.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

gwRARP 1.3.6.1.4.1.177.3.9.3
This parameter is not supported. A get on this OID will return disabled. A set on this OID will have no effect.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

gwRIP 1.3.6.1.4.1.177.3.9.4
Enable or disable the use of RIP (Routing Information Protocol). With RIP disabled, the user must install static routes on the attached workstation. Default state is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

gwIPAccessTable 1.3.6.1.4.1.177.3.9.5
A table of IP host or network addresses whose managers are allowed to access the FRX gateway.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GwIPAccessEntry

gwIPAccessEntry 1.3.6.1.4.1.177.3.9.5.1
An IP host or network addresses whose managers are allowed to access the FRX gateway.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GwIPAccessEntry  

gwIPAccessRowStatus 1.3.6.1.4.1.177.3.9.5.1.1
Auxiliary variable used to create or delete row instances in the gateway's IP address access table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

gwIPAccessAddress 1.3.6.1.4.1.177.3.9.5.1.2
The IP address of a host or network that is allowed to access the FRX gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dsx1ConfigEntry 1.3.6.1.4.1.177.3.10.1
OBJECT IDENTIFIER    

dsx1Initialized 1.3.6.1.4.1.177.3.10.1.1
Used to pad the wan structure in wan.h; it is not used for SNMP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..1  

dsx1TimeElapsed 1.3.6.1.4.1.177.3.10.1.2
The number of seconds that have elapsed since the beginning of the current error-measurement period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..899  

dsx1ValidIntervals 1.3.6.1.4.1.177.3.10.1.3
The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought on-line within the last 24 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..96  

dsx1LineType 1.3.6.1.4.1.177.3.10.1.4
This variable indicates the variety of DS1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: dsx1ESF Extended SuperFrame DS1 dsx1D4 AT&T D4 format DS1 dsx1E1 CCITT Recommendation G.704 (Table 4a) dsx1E1-CRC CCITT Recommendation G.704 (Table 4b) dsxE1-MF G.704 (Table 4a) with TS16 multiframing enabled dsx1E1-CRC-MF G.704 (Table 4b) with TS16 multiframing enabled
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), dsx1ESF(2), dsx1D4(3), dsx1E1(4), dsx1E1-CRC(5), dsx1E1-MF(6), dsx1E1-CRC-MF(7)  

dsx1LineCoding 1.3.6.1.4.1.177.3.10.1.5
This variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. dsx1B8ZS refers to the use of a specified pat- tern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits. ANSI Clear Channels may use dsx1ZBTSI, or Zero Byte Time Slot Interchange. E1 links, with or without CRC, use dsx1HDB3 or dsx1AMI. dsx1AMI refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density re- quirements, such as inverting HDLC data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dsx1B8ZS(1), dsx1HDB3(2), dsx1ZBTSI(3), dsx1AMI(4), other(5)  

dsx1SendCode 1.3.6.1.4.1.177.3.10.1.6
This variable indicates what type of code is being sent across the DS1 interface by the dev- ice. The values mean: dsx1SendNoCode sending looped or normal data dsx1SendLineCode sending a request for a line loopback dsx1SendPayloadCode sending a request for a payload loopback dsx1SendResetCode sending a loopback termination request dsx1SendQRS sending a Quasi-Random Signal (QRS) test pattern dsx1Send511Pattern sending a 511 bit fixed test pattern dsx1Send3in24Pattern sending a fixed test pattern of 3 bits set in 24 dsx1SendOtherTestPattern sending a test pattern other than those described by this object
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dsx1SendNoCode(1), dsx1SendLineCode(2), dsx1SendPayloadCode(3), dsx1SendResetCode(4), dsx1SendQRS(5), dsx1Send511Pattern(6), dsx1Send3in24Pattern(7), dsx1SendOtherTestPattern(8)  

dsx1CircuitIdentifier 1.3.6.1.4.1.177.3.10.1.7
This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

dsx1LoopbackConfig 1.3.6.1.4.1.177.3.10.1.8
This variable represents the loopback confi- guration of the DS1 interface. Agents support- ing read/write access should return badValue in response to a requested loopback state that the interface does not support. The values mean: dsx1NoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as it's value. dsx1PayloadLoop The received signal at this interface is looped through the device. Typically the received signal is looped back for re- transmission after it has passed through the device's framing function. dsx1LineLoop The received signal at this interface does not go through the device (minimum pene- tration) but is looped back out. dsx1OtherLoop Loopbacks that are not defined here.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dsx1NoLoop(1), dsx1PayloadLoop(2), dsx1LineLoop(3), dsx1OtherLoop(4)  

dsx1LineStatus 1.3.6.1.4.1.177.3.10.1.9
This variable indicates the Line Status of the interface. It contains loopback, failure, re- ceived 'alarm' and transmitted 'alarm' infor- mation. -- The dsx1LineStatus is a bit map represented as a sum, -- therefore, it can represent multiple failures (alarms) and -- a LoopbackState simultaneously. -- dsx1NoAlarm should be set if and only if no other flag is -- set. -- If the dsx1LoopbackState bit is set, the loopback in ef- -- fect can be determined from the dsx1LoopbackConfig object. -- The various bit positions are: -- 1 dsx1NoAlarm No Alarm Present -- 2 dsx1RcvFarEndLOF Far end LOF (a.k.a. Yellow Alarm) -- 4 dsx1XmtFarEndLOF Near end sending LOF Indication -- 8 dsx1RcvAIS Far end sending AIS -- 16 dsx1XmtAIS Near end sending AIS -- 32 dsx1LossOfFrame Near end LOF (a.k.a. Red Alarm) -- 64 dsx1LossOfSignal Near end Loss Of Signal -- 128 dsx1LoopbackState Near end is looped -- 256 dsx1T16AIS E1 TS16 AIS -- 512 dsx1RcvFarEndLOMF Far End Sending TS16 LOMF -- 1024 dsx1XmtFarEndLOMF Near End Sending TS16 LOMF -- 2048 dsx1RcvTestCode Near End detects a test code -- 4096 dsx1OtherFailure any line status not defined here
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8191  

dsx1LineMode 1.3.6.1.4.1.177.3.10.1.10
This set of values describes the mode of the WAN I/F. For DS1 lines it sets the mode to CSU by way of a standard dB level, and for DSX configurations sets the line buildout in feet. for E1 lines, it sets the mode in Ohm
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dsx1Mode0dB(1), dsx1Mode75dB(2), dsx1Mode15dB(3), dsx1Mode225dB(4), dsx1Mode133ft(5), dsx1Mode266ft(6), dsx1Mode399ft(7), dsx1Mode533ft(8), dsx1Mode655ft(9), dsx1Mode120Ohm(10), dsx1Mode75Ohm(11)  

dsx1TransmitClockSource 1.3.6.1.4.1.177.3.10.1.11
The source of Tranmit Clock. 'loopTiming' indicates that the recovered re- ceive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used. 'throughTiming' indicates that recovered re- ceive clock from another interface is ised as the transmit clock.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), throughTiming(3)  

dsx1Fdl 1.3.6.1.4.1.177.3.10.1.12
This bitmap describes the use of the facili- ties data link, and is the sum of the capabili- ties: 'other' indicates that a protocol other than one following is used. 'dsx1Ansi-T1-403' refers to the FDL exchange recommended by ANSI. (This is a T1-only option.) 'dsx1Att-54016' refers to ESF FDL exchanges. (This is a T1-only option.) 'dsx1Fdl-none' indicates that the device does not use the FDL.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), dsx1Ansi-T1-403(2), dsx1Att-54016(4), dsx1Ansi-T1-403-Att-54016(6), dsx1Fdl-none(8)  

dsx1YellowAlarmStyle 1.3.6.1.4.1.177.3.10.1.13
This variable describes the use of the yellow alarm style when in D4 line encoding mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER usaYellowAlarms(1), japaneseYellowAlarms(2)  

dsx1CurrentTable 1.3.6.1.4.1.177.3.10.2
The DS1 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1CurrentEntry

dsx1CurrentEntry 1.3.6.1.4.1.177.3.10.2.1
An entry in the DS1 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Dsx1CurrentEntry  

dsx1CurrentIndex 1.3.6.1.4.1.177.3.10.2.1.1
The index value which uniquely identifies the DS1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

dsx1CurrentESs 1.3.6.1.4.1.177.3.10.2.1.2
The number of Errored Seconds, encountered by a DS1 interface in the current 15 minute inter- val.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1CurrentSESs 1.3.6.1.4.1.177.3.10.2.1.3
The number of Severely Errored Seconds encoun- tered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1CurrentSEFSs 1.3.6.1.4.1.177.3.10.2.1.4
The number of Severely Errored Framing Seconds encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1CurrentUASs 1.3.6.1.4.1.177.3.10.2.1.5
The number of Unavailable Seconds encountered by a DS1 interface in the current 15 minute in- terval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1CurrentCSSs 1.3.6.1.4.1.177.3.10.2.1.6
The number of Controlled Slip Seconds encoun- tered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1CurrentPCVs 1.3.6.1.4.1.177.3.10.2.1.7
The number of Path Coding Violations encoun- tered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1CurrentLESs 1.3.6.1.4.1.177.3.10.2.1.8
The number of Line Errored Seconds encountered by a DS1 interface in the current 15 minute in- terval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1CurrentBESs 1.3.6.1.4.1.177.3.10.2.1.9
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1CurrentDMs 1.3.6.1.4.1.177.3.10.2.1.10
The number of Degraded Minutes (DMs) encoun- tered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1CurrentLCVs 1.3.6.1.4.1.177.3.10.2.1.11
The number of Line Code Violations (LCVs) en- countered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalTable 1.3.6.1.4.1.177.3.10.3
The DS1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1IntervalEntry

dsx1IntervalEntry 1.3.6.1.4.1.177.3.10.3.1
An entry in the DS1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Dsx1IntervalEntry  

dsx1IntervalIndex 1.3.6.1.4.1.177.3.10.3.1.1
The index value which uniquely identifies the DS1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

dsx1IntervalNumber 1.3.6.1.4.1.177.3.10.3.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes inter- val (assuming that all 96 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

dsx1IntervalESs 1.3.6.1.4.1.177.3.10.3.1.3
The number of Errored Seconds encountered by a DS1 interface in one of the previous 96, indi- vidual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalSESs 1.3.6.1.4.1.177.3.10.3.1.4
The number of Severely Errored Seconds encoun- tered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalSEFSs 1.3.6.1.4.1.177.3.10.3.1.5
The number of Severely Errored Framing Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalUASs 1.3.6.1.4.1.177.3.10.3.1.6
The number of Unavailable Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalCSSs 1.3.6.1.4.1.177.3.10.3.1.7
The number of Controlled Slip Seconds encoun- tered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalPCVs 1.3.6.1.4.1.177.3.10.3.1.8
The number of Path Coding Violations encoun- tered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalLESs 1.3.6.1.4.1.177.3.10.3.1.9
The number of Line Errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalBESs 1.3.6.1.4.1.177.3.10.3.1.10
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalDMs 1.3.6.1.4.1.177.3.10.3.1.11
The number of Degraded Minutes (DMs) encoun- tered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1IntervalLCVs 1.3.6.1.4.1.177.3.10.3.1.12
The number of Line Code Violations (LCVs) en- countered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalTable 1.3.6.1.4.1.177.3.10.4
The DS1 Total table. 24 hour interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1TotalEntry

dsx1TotalEntry 1.3.6.1.4.1.177.3.10.4.1
An entry in the DS1 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Dsx1TotalEntry  

dsx1TotalIndex 1.3.6.1.4.1.177.3.10.4.1.1
The index value which uniquely identifies the DS1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

dsx1TotalESs 1.3.6.1.4.1.177.3.10.4.1.2
The number of Errored Seconds encountered by a DS1 interface in the previous 24 hour interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalSESs 1.3.6.1.4.1.177.3.10.4.1.3
The number of Severely Errored Seconds encoun- tered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalSEFSs 1.3.6.1.4.1.177.3.10.4.1.4
The number of Severely Errored Framing Seconds encountered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalUASs 1.3.6.1.4.1.177.3.10.4.1.5
The number of Unavailable Seconds encountered by a DS1 interface in the previous 24 hour in- terval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalCSSs 1.3.6.1.4.1.177.3.10.4.1.6
The number of Controlled Slip Seconds encoun- tered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalPCVs 1.3.6.1.4.1.177.3.10.4.1.7
The number of Path Coding Violations encoun- tered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalLESs 1.3.6.1.4.1.177.3.10.4.1.8
The number of Line Errored Seconds encountered by a DS1 interface in the previous 24 hour in- terval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalBESs 1.3.6.1.4.1.177.3.10.4.1.9
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalDMs 1.3.6.1.4.1.177.3.10.4.1.10
The number of Degraded Minutes (DMs) encoun- tered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1TotalLCVs 1.3.6.1.4.1.177.3.10.4.1.11
The number of Line Code Violations (LCVs) en- countered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndCurrentTable 1.3.6.1.4.1.177.3.10.5
The DS1 Far End Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1FarEndCurrentEntry

dsx1FarEndCurrentEntry 1.3.6.1.4.1.177.3.10.5.1
An entry in the DS1 Far End Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Dsx1FarEndCurrentEntry  

dsx1FarEndCurrentIndex 1.3.6.1.4.1.177.3.10.5.1.1
The index value which uniquely identifies the DS1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx1LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

dsx1FarEndTimeElapsed 1.3.6.1.4.1.177.3.10.5.1.2
The number of seconds that have elapsed since the beginning of the far end current error-measurement period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..899  

dsx1FarEndValidIntervals 1.3.6.1.4.1.177.3.10.5.1.3
The number of previous far end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute far end intervals since the interface has been online.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..96  

dsx1FarEndCurrentESs 1.3.6.1.4.1.177.3.10.5.1.4
The number of Far Far End Errored Seconds en- countered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndCurrentSESs 1.3.6.1.4.1.177.3.10.5.1.5
The number of Far End Severely Errored Seconds encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndCurrentSEFSs 1.3.6.1.4.1.177.3.10.5.1.6
The number of Far End Severely Errored Framing Seconds encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndCurrentUASs 1.3.6.1.4.1.177.3.10.5.1.7
The number of Unavailable Seconds encountered by a DS1 interface in the current 15 minute in- terval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndCurrentCSSs 1.3.6.1.4.1.177.3.10.5.1.8
The number of Far End Controlled Slip Seconds encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndCurrentLESs 1.3.6.1.4.1.177.3.10.5.1.9
The number of Far End Line Errored Seconds en- countered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndCurrentPCVs 1.3.6.1.4.1.177.3.10.5.1.10
The number of Far End Path Coding Violations reported via the far end block error count en- countered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndCurrentBESs 1.3.6.1.4.1.177.3.10.5.1.11
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndCurrentDMs 1.3.6.1.4.1.177.3.10.5.1.12
The number of Degraded Minutes (DMs) encoun- tered by a DS1 interface in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndIntervalTable 1.3.6.1.4.1.177.3.10.6
The DS1 Far End Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1FarEndIntervalEntry

dsx1FarEndIntervalEntry 1.3.6.1.4.1.177.3.10.6.1
An entry in the DS1 Far End Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Dsx1FarEndIntervalEntry  

dsx1FarEndIntervalIndex 1.3.6.1.4.1.177.3.10.6.1.1
The index value which uniquely identifies the DS1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

dsx1FarEndIntervalNumber 1.3.6.1.4.1.177.3.10.6.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes inter- val (assuming that all 96 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

dsx1FarEndIntervalESs 1.3.6.1.4.1.177.3.10.6.1.3
The number of Far End Errored Seconds encoun- tered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndIntervalSESs 1.3.6.1.4.1.177.3.10.6.1.4
The number of Far End Severely Errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndIntervalSEFSs 1.3.6.1.4.1.177.3.10.6.1.5
The number of Far End Severely Errored Framing Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, in- tervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndIntervalUASs 1.3.6.1.4.1.177.3.10.6.1.6
The number of Unavailable Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndIntervalCSSs 1.3.6.1.4.1.177.3.10.6.1.7
The number of Far End Controlled Slip Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndIntervalLESs 1.3.6.1.4.1.177.3.10.6.1.8
The number of Far End Line Errored Seconds en- countered by a DS1 interface in one of the pre- vious 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndIntervalPCVs 1.3.6.1.4.1.177.3.10.6.1.9
The number of Far End Path Coding Violations reported via the far end block error count en- countered by a DS1 interface in one of the pre- vious 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndIntervalBESs 1.3.6.1.4.1.177.3.10.6.1.10
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndIntervalDMs 1.3.6.1.4.1.177.3.10.6.1.11
The number of Degraded Minutes (DMs) encoun- tered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndTotalTable 1.3.6.1.4.1.177.3.10.7
The DS1 Far End Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1FarEndTotalEntry

dsx1FarEndTotalEntry 1.3.6.1.4.1.177.3.10.7.1
An entry in the DS1 Far End Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Dsx1FarEndTotalEntry  

dsx1FarEndTotalIndex 1.3.6.1.4.1.177.3.10.7.1.1
The index value which uniquely identifies the DS1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx1LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

dsx1FarEndTotalESs 1.3.6.1.4.1.177.3.10.7.1.2
The number of Far End Errored Seconds encoun- tered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndTotalSESs 1.3.6.1.4.1.177.3.10.7.1.3
The number of Far End Severely Errored Seconds encountered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndTotalSEFSs 1.3.6.1.4.1.177.3.10.7.1.4
The number of Far End Severely Errored Framing Seconds encountered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndTotalUASs 1.3.6.1.4.1.177.3.10.7.1.5
The number of Unavailable Seconds encountered by a DS1 interface in the previous 24 hour in- terval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndTotalCSSs 1.3.6.1.4.1.177.3.10.7.1.6
The number of Far End Controlled Slip Seconds encountered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndTotalLESs 1.3.6.1.4.1.177.3.10.7.1.7
The number of Far End Line Errored Seconds en- countered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndTotalPCVs 1.3.6.1.4.1.177.3.10.7.1.8
The number of Far End Path Coding Violations reported via the far end block error count en- countered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndTotalBESs 1.3.6.1.4.1.177.3.10.7.1.9
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1FarEndTotalDMs 1.3.6.1.4.1.177.3.10.7.1.10
The number of Degraded Minutes (DMs) encoun- tered by a DS1 interface in the previous 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

dsx1ChanOwnerTable 1.3.6.1.4.1.177.3.10.8
The DS1 Channel-to-Port mapping table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1ChanOwnerEntry

dsx1ChanOwnerEntry 1.3.6.1.4.1.177.3.10.8.1
An entry in the dsx1ChanOwner table, indexed by channel showing which logical port owns this channel. An entry of -1 depicts a channel that is freely assignable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Dsx1ChanOwnerEntry  

dsx1ChanIndex 1.3.6.1.4.1.177.3.10.8.1.1
The index value which uniquely identifies the DSX channel to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

dsx1ChanOwnerPort 1.3.6.1.4.1.177.3.10.8.1.2
The number of the port to which this channel is assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1..128  

dsx1PortModeTable 1.3.6.1.4.1.177.3.10.9
The DS1 Logical Port-to-Mode mapping table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1PortModeEntry

dsx1PortModeEntry 1.3.6.1.4.1.177.3.10.9.1
An entry in the DS1 Port->Mode table, indexed by port showing which mode this port runs in. An entry of 0 depicts a port that is operating in the DS0 mode, a non-zero entry indicates the 56K mode. Note that a DS1 link operating JBZS will always have all of its channels operating in 56K mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Dsx1PortModeEntry  

dsx1PortMode 1.3.6.1.4.1.177.3.10.9.1.1
The port mode of the T1/E1 Back Card port to which this entry is applicable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER modeDS0(1), mode56K(2)  

dsx1PortIndex 1.3.6.1.4.1.177.3.10.9.1.2
The index value which uniquely identifies the T1/E1 Back Card port to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

exportFileSystem 1.3.6.1.4.1.177.3.11.1
Determines whether this node will export its filesystem. The default will be . This variable can be changed by the FrameXpress Node Manager. When the agent receives the request to change this variable to , it attempts to export the file system prior to responding to the Node Manager. If the export fails, the SNMP request will fail sending a failure response to the Manager.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notExported(1), exported(2)  

loadAndExecute 1.3.6.1.4.1.177.3.11.2
Triggers the loading of SNMPCNF.CMD if such a file existed, otherwise, it triggers the loading of DEFAULT.CFG after clearing the current configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notloading(1), loading(2)  

systemRestartTrap 1
This trap is sent when the system restarts for any reason other than an operator requested restart.
TRAP-TYPE    

systemSyserrTrap 2
This trap is sent when the system detects a inconsistency. This may cause a reset of the FRX node.
TRAP-TYPE    

configChangedTrap 3
This trap is sent when a new configuration is saved in the non-volatile storage.
TRAP-TYPE    

nodeCongestedTrap 4
This trap is sent when the FRX node becomes congested.
TRAP-TYPE    

portInstalledTrap 5
This trap is sent when a port is installed.
TRAP-TYPE    

portDeletedTrap 6
This trap is sent when a port is deleted.
TRAP-TYPE    

portActivatedTrap 7
This trap is sent when a port is activated.
TRAP-TYPE    

portDisabledTrap 8
This trap is sent when a port is disabled.
TRAP-TYPE    

portCongestedTrap 9
This trap is sent when a port is congested.
TRAP-TYPE    

pvcInstalledTrap 10
This trap is sent when a virtual circuit is installed.
TRAP-TYPE    

pvcDeletedTrap 11
This trap is sent when a virtual circuit is deleted.
TRAP-TYPE    

pvcActivatedTrap 12
This trap is sent when a virtual circuit is activated.
TRAP-TYPE    

pvcDisabledTrap 13
This trap is sent when a virtual circuit is disabled.
TRAP-TYPE    

pvcStatusActiveTrap 14
This trap is sent when the status for a virtual circuit become active.
TRAP-TYPE    

pvcStatusInactiveTrap 15
This trap is sent when the status for a virtual circuit become inactive.
TRAP-TYPE    

cbusUpTrap 16
This trap is sent when the CBUS interface is ready for use.
TRAP-TYPE    

cbusDownTrap 17
This trap is sent when the CBUS interface becomes invalid.
TRAP-TYPE    

serialFailTrap 18
This trap is sent when an HDLC port fails to initialize.
TRAP-TYPE    

portUniActiveTrap 19
This trap is sent when a port's UNI protocol becomes active.
TRAP-TYPE    

portUniInactiveTrap 20
This trap is sent when a port's UNI protocol becomes inactive.
TRAP-TYPE    

portIDNXCallUpTrap 21
This trap is sent when a port's IDNX call (bandwidth) is available.
TRAP-TYPE    

portIDNXCallDownTrap 22
This trap is sent when a port's IDNX call (bandwidth) becomes unavailable.
TRAP-TYPE    

nodeNotCongestedTrap 23
This trap is sent when a FRX node goes from being congested to not being congested.
TRAP-TYPE    

portNotCongestedTrap 24
This trap is sent when a port goes from being congested to not being congested.
TRAP-TYPE    

operatorResetTrap 25
This trap is sent when the operator requests a reset of the FRX.
TRAP-TYPE    

eventLogClearedTrap 26
This trap is sent when the operator requests to clear the FRX event log.
TRAP-TYPE    

configClearedTrap 27
This trap is sent when the operator requests to clear the configuration of an FRX.
TRAP-TYPE    

functionMismatchTrap 28
This trap is sent when the code type (FRX) does not match the value stored in the IDNX database.
TRAP-TYPE    

eventLogErrorTrap 29
This trap is sent when the FRX is unable to create an event log.
TRAP-TYPE    

encapActiveTrap 30
This trap is sent when frame relay encapsulation is turned on for a PVC.
TRAP-TYPE    

encapInactiveTrap 31
This trap is sent when frame relay encapsulation is turned off for a PVC.
TRAP-TYPE    

altPathUsedTrap 32
This trap is sent when a path alternate to the preferred path is used to setup a pvc.
TRAP-TYPE    

pvcStateIdleTrap 33
The state of a PVC describes the current status of call setup. This trap is sent when a PVC's state changes to Idle.
TRAP-TYPE    

pvcStateSetupTrap 34
The state of a PVC describes the current status of call setup. This trap is sent when a PVC's state changes to Setup.
TRAP-TYPE    

pvcStateCompleteTrap 35
The state of a PVC describes the current status of call setup. This trap is sent when a PVC's state changes to Complete.
TRAP-TYPE    

pvcStateDisconnectTrap 36
The state of a PVC describes the current status of call setup. This trap is sent when a PVC's state changes to Disconnect.
TRAP-TYPE    

billingDownloadSuccessTrap 37
A Billing file was successfully downloaded from the FRX.
TRAP-TYPE    

billingDownloadFailureTrap 38
An error occurred while the FRX attempted to download a Billing file.
TRAP-TYPE    

billingDownloadThresholdTrap 39
An attempt was made to set an obsolete Billing download threshold parameter.
TRAP-TYPE    

configSyntaxErrorTrap 40
A line in the FRX configuration file had a syntax error when it was loaded; the line was ignored.
TRAP-TYPE    

configDownloadSuccessTrap 41
A Configuration file was successfully downloaded from the FRX.
TRAP-TYPE    

configDownloadFailureTrap 42
An error occurred while the FRX attempted to download a Configuration file.
TRAP-TYPE    

nodeFlashMemErr 50
This trap indicates that a code checksum error occurred in Flash.
TRAP-TYPE    

nodeFlashWriteErr 51
This trap indicates that a code transfer to Flash occurred. Flash may now be corrupted.
TRAP-TYPE    

nodeUserLogin 52
A user has logged into the FRX through the serial console or network.
TRAP-TYPE    

nodeUserLogout 53
A user has logged out.
TRAP-TYPE    

dsx1NoAlarm 54
No alarm present.
TRAP-TYPE    

dsx1RcvFarEndLOF 55
Far end LOF (a.k.a. Yellow Alarm).
TRAP-TYPE    

dsx1RcvFarEndLOFEnded 56
Far end LOF (a.k.a. Yellow Alarm) indication has ended.
TRAP-TYPE    

dsx1XmtFarEndLOF 57
Near end sending LOF Indication.
TRAP-TYPE    

dsx1XmtFarEndLOFEnding 58
Near end ending LOF Indication.
TRAP-TYPE    

dsx1RcvAIS 59
Far end sending AIS.
TRAP-TYPE    

dsx1RcvAISEnded 60
Far end AIS has ceased.
TRAP-TYPE    

dsx1XmtAIS 61
Near end sending AIS indication.
TRAP-TYPE    

dsx1XmtAISEnding 62
Near end ending AIS indication.
TRAP-TYPE    

dsx1LossOfFrame 63
Near end LOF (a.k.a. Red Alarm).
TRAP-TYPE    

dsx1LossOfFrameEnded 64
Near end LOF (a.k.a. Red Alarm) indication has ended.
TRAP-TYPE    

dsx1LossOfSignal 65
Near end Loss Of Signal.
TRAP-TYPE    

dsx1LossOfSignalEnded 66
Near end Loss Of Signal indication has ended.
TRAP-TYPE    

dsx1LoopbackState 67
Near end is looped.
TRAP-TYPE    

dsx1LoopbackStateEnded 68
Near end is un-looped.
TRAP-TYPE    

dsx1T16AIS 69
E1 TS16 AIS indication received.
TRAP-TYPE    

dsx1T16AISEnded 70
E1 TS16 AIS indication has ended.
TRAP-TYPE    

dsx1RcvFarEndLOMF 71
Far End sending TS16 LOMF.
TRAP-TYPE    

dsx1RcvFarEndLOMFEnded 72
Far End ending TS16 LOMF.
TRAP-TYPE    

dsx1XmtFarEndLOMF 73
Near End sending TS16 LOMF.
TRAP-TYPE    

dsx1XmtFarEndLOMFEnding 74
Near End ending TS16 LOMF.
TRAP-TYPE    

dsx1RcvTestCode 75
Near End detected a test code.
TRAP-TYPE    

dsx1OtherFailure 76
Unknown line status received.
TRAP-TYPE    

nodeAlarmedPortsZero 77
The value of nodeAlarmedPorts became zero.
TRAP-TYPE    

portAlarmedPVCsZero 78
The value of portAlarmedPVCs for this port became zero.
TRAP-TYPE    

operatorInstallTrap 79
This trap is sent when a new operator is installed.
TRAP-TYPE    

operatorDeleteTrap 80
This trap is sent when an operator is deleted.
TRAP-TYPE    

portPVCReOptimizationStart 81
This trap is sent when PVC ReOptimization has started.
TRAP-TYPE    

portPVCReOptimizationEnd 82
This trap is sent when PVC ReOptimization has ended.
TRAP-TYPE