FLARION-TRAP-MIB

File: FLARION-TRAP-MIB.mib (15651 bytes)

Imported modules

SNMPv2-SMI FLARION-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
flarion rrCommonMib AlarmSeverity
MoType AddtlInfo

Defined Values

flarionTraps 1.3.6.1.4.1.8603.10
OBJECT IDENTIFIER    

flaTrapVars 1.3.6.1.4.1.8603.10.1
OBJECT IDENTIFIER    

flaTraps 1.3.6.1.4.1.8603.10.2
OBJECT IDENTIFIER    

flaTrapPrefix 1.3.6.1.4.1.8603.10.2.0
OBJECT IDENTIFIER    

flaTimeStamp 1.3.6.1.4.1.8603.10.1.1
The time at which the event was generated. This value is expressed in seconds since 00:00:00 UTC, January 1, 1970 (see time(2)).
OBJECT-TYPE    
  INTEGER  

flaSeqNum 1.3.6.1.4.1.8603.10.1.2
The event sequence number.
OBJECT-TYPE    
  INTEGER  

flaSeverity 1.3.6.1.4.1.8603.10.1.3
The event severity.
OBJECT-TYPE    
  AlarmSeverity  

flaMoType 1.3.6.1.4.1.8603.10.1.4
Type managed object associated with this trap.
OBJECT-TYPE    
  MoType  

flaMoId 1.3.6.1.4.1.8603.10.1.5
The instance of the managed object logical identifier.
OBJECT-TYPE    
  INTEGER 0..65535  

flaAddtlInfo 1.3.6.1.4.1.8603.10.1.6
Event description.
OBJECT-TYPE    
  AddtlInfo  

mcuBootStatusUp 1.3.6.1.4.1.8603.10.2.0.1
The MCU software is up and running.
NOTIFICATION-TYPE    

mcuBootStatusDown 1.3.6.1.4.1.8603.10.2.0.2
The MCU software is shutting down.
NOTIFICATION-TYPE    

mcuOperStatusUp 1.3.6.1.4.1.8603.10.2.0.3
MCU operational status is up.
NOTIFICATION-TYPE    

mcuOperStatusDown 1.3.6.1.4.1.8603.10.2.0.4
MCU operational status is down.
NOTIFICATION-TYPE    

mlpppStatusUp 1.3.6.1.4.1.8603.10.2.0.5
Multilink PPP status is up.
NOTIFICATION-TYPE    

mlpppStatusDown 1.3.6.1.4.1.8603.10.2.0.6
Multilink PPP status is up.
NOTIFICATION-TYPE    

bbuOperStatusUp 1.3.6.1.4.1.8603.10.2.0.7
BBU card operational status is up.
NOTIFICATION-TYPE    

bbuOperStatusDown 1.3.6.1.4.1.8603.10.2.0.8
BBU card operational status is down.
NOTIFICATION-TYPE    

bbuOperStatusNotPresent 1.3.6.1.4.1.8603.10.2.0.9
BBU card operational status is not present.
NOTIFICATION-TYPE    

bbuTempNormal 1.3.6.1.4.1.8603.10.2.0.10
BBU temperature has transitioned inot normal operating range.
NOTIFICATION-TYPE    

bbuTempHigh 1.3.6.1.4.1.8603.10.2.0.11
BBU temperature has transitioned into a high operating range.
NOTIFICATION-TYPE    

bbuTempSevere 1.3.6.1.4.1.8603.10.2.0.12
BBU temperature has transitioned into a severe operating range.
NOTIFICATION-TYPE    

bbuTempCritical 1.3.6.1.4.1.8603.10.2.0.13
BBU temperature has transitioned into a critical operating range.
NOTIFICATION-TYPE    

bbuVoltageNormal 1.3.6.1.4.1.8603.10.2.0.14
BBU voltage has transitioned into normal operating range.
NOTIFICATION-TYPE    

bbuVoltageHigh 1.3.6.1.4.1.8603.10.2.0.15
BBU voltage has transitioned above normal operating limits.
NOTIFICATION-TYPE    

bbuVoltageLow 1.3.6.1.4.1.8603.10.2.0.16
BBU voltage has transitioned below normal operating limits.
NOTIFICATION-TYPE    

dspStatusActive 1.3.6.1.4.1.8603.10.2.0.17
DSP has transitioned into the Active state. In this state, mobiles are allowed to establish connections and data traffic can be received/transmitted.
NOTIFICATION-TYPE    

dspStatusStandby 1.3.6.1.4.1.8603.10.2.0.18
DSP has transitioned into the Disabled/Standby state. In this state, mobiles can not establish connections and data traffic can not be received/transmitted. This is typically caused by administrative intervention or the DSP has initiated this state change due to an alarm condition elsewhere in the system.
NOTIFICATION-TYPE    

dspStatusOos 1.3.6.1.4.1.8603.10.2.0.19
DSP has transitioned into the Out of Service state.
NOTIFICATION-TYPE    

dspStatusNonOperational 1.3.6.1.4.1.8603.10.2.0.20
DSP has transitioned into the Non Operational state. This state is entered when the system is unable to determine the condition of the DSP.
NOTIFICATION-TYPE    

accountingRadiusUp 1.3.6.1.4.1.8603.10.2.0.21
Accounting/RADIUS server is up.
NOTIFICATION-TYPE    

accountingRadiusDown 1.3.6.1.4.1.8603.10.2.0.22
Accounting/RADIUS server is down.
NOTIFICATION-TYPE    

rrTrapVars 1.3.6.1.4.1.8603.1.1.1
OBJECT IDENTIFIER    

rrTraps 1.3.6.1.4.1.8603.1.1.2
OBJECT IDENTIFIER    

rrTimeStamp 1.3.6.1.4.1.8603.1.1.1.1
The time at which the event was generated. This value is expressed in seconds since 00:00:00 UTC, January 1, 1970 (see time(2)).
OBJECT-TYPE    
  INTEGER  

rrSeqNum 1.3.6.1.4.1.8603.1.1.1.2
The event sequence number.
OBJECT-TYPE    
  INTEGER  

rrSeverity 1.3.6.1.4.1.8603.1.1.1.3
The event severity.
OBJECT-TYPE    
  AlarmSeverity  

rrMoType 1.3.6.1.4.1.8603.1.1.1.4
Type managed object associated with this trap.
OBJECT-TYPE    
  MoType  

rrMoId 1.3.6.1.4.1.8603.1.1.1.5
The instance of the managed object logical identifier.
OBJECT-TYPE    
  INTEGER 0..65535  

rrAddtlInfo 1.3.6.1.4.1.8603.1.1.1.6
Event description.
OBJECT-TYPE    
  AddtlInfo  

rrTrapSpecific 1.3.6.1.4.1.8603.1.1.2.0
OBJECT IDENTIFIER    

alarmTrap 1.3.6.1.4.1.8603.1.1.2.0.1
Alarm notification.
NOTIFICATION-TYPE    

bootStatusUp 1.3.6.1.4.1.8603.1.1.2.0.2
The system is up and running.
NOTIFICATION-TYPE    

bootStatusDown 1.3.6.1.4.1.8603.1.1.2.0.3
The system has failed to boot or the system is shutting down.
NOTIFICATION-TYPE    

mcuOperStatus 1.3.6.1.4.1.8603.1.1.2.0.120
MCU operational status changed.
NOTIFICATION-TYPE    

mcuFaultLedStatus 1.3.6.1.4.1.8603.1.1.2.0.121
MCU fault LED status changed.
NOTIFICATION-TYPE    

mcuTempStatus 1.3.6.1.4.1.8603.1.1.2.0.122
MCU temperature status changed.
NOTIFICATION-TYPE    

mcuVoltageStatus 1.3.6.1.4.1.8603.1.1.2.0.123
MCU voltage status changed.
NOTIFICATION-TYPE    

mlpppStatus 1.3.6.1.4.1.8603.1.1.2.0.160
Multilink PPP status changed.
NOTIFICATION-TYPE    

bbuOperStatus 1.3.6.1.4.1.8603.1.1.2.0.200
BBU operational status changed.
NOTIFICATION-TYPE    

bbuFaultLedStatus 1.3.6.1.4.1.8603.1.1.2.0.201
BBU fault LED status changed.
NOTIFICATION-TYPE    

bbuTempStatus 1.3.6.1.4.1.8603.1.1.2.0.202
BBU temperature status changed.
NOTIFICATION-TYPE    

bbuVoltageStatus 1.3.6.1.4.1.8603.1.1.2.0.203
BBU voltage status changed.
NOTIFICATION-TYPE    

bbuDspStatus 1.3.6.1.4.1.8603.1.1.2.0.204
BBU DSP status changed.
NOTIFICATION-TYPE    

alarmInputStatus 1.3.6.1.4.1.8603.1.1.2.0.280
Alarm input status changed.
NOTIFICATION-TYPE    

accountingRadiusStatus 1.3.6.1.4.1.8603.1.1.2.0.350
Accounting/RADIUS server status changed.
NOTIFICATION-TYPE