FJ-BBU-MIB

File: FJ-BBU-MIB.mib (14427 bytes)

Imported modules

RFC-1212 RFC1213-MIB RFC1155-SMI

Imported symbols

OBJECT-TYPE mib-2 DisplayString
Counter Gauge IpAddress
enterprises

Defined Values

fujitsu 1.3.6.1.4.1.211
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.211.1
OBJECT IDENTIFIER    

iaServer 1.3.6.1.4.1.211.1.31
OBJECT IDENTIFIER    

primergy 1.3.6.1.4.1.211.1.31.3
OBJECT IDENTIFIER    

iBBU 1.3.6.1.4.1.211.1.31.3.1
OBJECT IDENTIFIER    

connectionInfo 1.3.6.1.4.1.211.1.31.3.1.1
OBJECT IDENTIFIER    

batteryError 1.3.6.1.4.1.211.1.31.3.1.2
OBJECT IDENTIFIER    

batteryWarning 1.3.6.1.4.1.211.1.31.3.1.3
OBJECT IDENTIFIER    

batteryInfo 1.3.6.1.4.1.211.1.31.3.1.4
OBJECT IDENTIFIER    

managementInfo 1.3.6.1.4.1.211.1.31.3.1.5
OBJECT IDENTIFIER    

fjbbuNotifications 1.3.6.1.4.1.211.1.31.3.1.6
OBJECT IDENTIFIER    

connectionError 1.3.6.1.4.1.211.1.31.3.1.1.1
Connection error with the Internal Battery Unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

overTempDDC 1.3.6.1.4.1.211.1.31.3.1.2.1
Over temperature in DC/DC converter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

overVoltDDC 1.3.6.1.4.1.211.1.31.3.1.2.2
Over voltage protection in DC/DC converter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

chargePassError 1.3.6.1.4.1.211.1.31.3.1.2.3
Charge path failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

dischargePassError 1.3.6.1.4.1.211.1.31.3.1.2.4
Discharge path failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

thermistorError 1.3.6.1.4.1.211.1.31.3.1.2.5
Thermistor failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

chargeCircuitError 1.3.6.1.4.1.211.1.31.3.1.2.6
Charge circuit failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

dc12VError 1.3.6.1.4.1.211.1.31.3.1.2.7
DC12V failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

fanError 1.3.6.1.4.1.211.1.31.3.1.2.8
FAN alarm
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

trickleChargeError 1.3.6.1.4.1.211.1.31.3.1.2.9
Tricle charge failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

eepromAccessError 1.3.6.1.4.1.211.1.31.3.1.2.10
EEPROM access failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

dischargeCurrentError 1.3.6.1.4.1.211.1.31.3.1.2.11
Over current (SW) in discharging
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

chargeCurrentError 1.3.6.1.4.1.211.1.31.3.1.2.12
Over current (SW) in charging
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), error(3)  

capacityWarning 1.3.6.1.4.1.211.1.31.3.1.3.1
Battery capacity failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), warning(3)  

voltageDropBatteryWarning 1.3.6.1.4.1.211.1.31.3.1.3.2
Voltage dropped
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), warning(3)  

overTempWarning 1.3.6.1.4.1.211.1.31.3.1.3.3
Over temperature
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), warning(3)  

impedanceWarning 1.3.6.1.4.1.211.1.31.3.1.3.4
Impedance alarm
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), warning(3)  

relativeStateOfCharge 1.3.6.1.4.1.211.1.31.3.1.4.1
Relative state of charge(percent)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

manufactureDate 1.3.6.1.4.1.211.1.31.3.1.4.2
Manufacture date (e.g. '20120202')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

serialNumber 1.3.6.1.4.1.211.1.31.3.1.4.3
Serial number (e.g. '00017')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

manufacturerName 1.3.6.1.4.1.211.1.31.3.1.4.4
Manufacturer name (e.g. 'FDK')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceName 1.3.6.1.4.1.211.1.31.3.1.4.5
Device name (e.g. 'TW181FJ2')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceChemistry 1.3.6.1.4.1.211.1.31.3.1.4.6
Device chemistry (e.g. 'NiMH')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

firmwareVersion 1.3.6.1.4.1.211.1.31.3.1.4.7
Firmware version (e.g. '4807')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

boardSerialNumber 1.3.6.1.4.1.211.1.31.3.1.4.8
Board Serial Number (e.g. 'BU1816AC31001')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

boardPartNumber 1.3.6.1.4.1.211.1.31.3.1.4.9
Board Part Number (e.g. 'CA05950-1414')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

boardVersion 1.3.6.1.4.1.211.1.31.3.1.4.10
Board Version (e.g. '01A')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

i2cAddress 1.3.6.1.4.1.211.1.31.3.1.5.1
I2C address of this BBU (e.g. '0xB2')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemStatus 1.3.6.1.4.1.211.1.31.3.1.5.2
System status. When BBU system error detected, it returns the value 'alarm'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), alarm(3)  

batteryStatus 1.3.6.1.4.1.211.1.31.3.1.5.3
Battery status. When BBU battery error detected, it returns the value 'alarm'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), alarm(3)  

workStatus 1.3.6.1.4.1.211.1.31.3.1.5.4
Work status. When AC fail detected, it returns the value 'discharging'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), waiting(2), charging(3), discharging(4)  

informationUrl 1.3.6.1.4.1.211.1.31.3.1.5.5
URL of information HTML interface (e.g. 'http://127.0.0.1:20080/bbuview/jsp/index.jsp')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceName 1.3.6.1.4.1.211.1.31.3.1.5.6
Device name (e.g. 'BBU')
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fjbbuNotificationsTrapInfo 1.3.6.1.4.1.211.1.31.3.1.6.1
OBJECT IDENTIFIER    

fjbbuTrapInfoServerName 1.3.6.1.4.1.211.1.31.3.1.6.1.1
Name of the server the trap comes from
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString  

fjbbuTrapInfoTime 1.3.6.1.4.1.211.1.31.3.1.6.1.2
Time when the trap occured (in seconds since 01/01/1970 00:00h)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

fjbbuTrapInfoDetail 1.3.6.1.4.1.211.1.31.3.1.6.1.3
Problem detail of the trap
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString  

fjbbuTrapInfoInformationUrl 1.3.6.1.4.1.211.1.31.3.1.6.1.4
URL of information HTML interface (e.g. 'http://127.0.0.1:20080/bbuview/jsp/index.jsp')
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString  

fjbbuTrapTest 2000
Test trap to verify trap connection.
TRAP-TYPE    

fjbbuTrapCommunicationFailure 2001
The communication with the Internal Battery Unit failed!
TRAP-TYPE    

fjbbuTrapCommunicationEstablished 2002
The communication with the Internal Battery Unit was reestablished
TRAP-TYPE    

fjbbuBatteryWarning 2003
Internal Battery Unit warning.
TRAP-TYPE    

fjbbuBatteryError 2004
Internal Battery Unit error.
TRAP-TYPE