FDDI-SMT73-MIB

File: FDDI-SMT73-MIB.mib (89819 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212

Imported symbols

Counter transmission OBJECT-TYPE

Defined Types

FddiTimeNano  
INTEGER 0..2147483647    

FddiTimeMilli  
INTEGER 0..2147483647    

FddiResourceId  
INTEGER 0..65535    

FddiSMTStationIdType  
OCTET STRING Size(8)    

FddiMACLongAddressType  
OCTET STRING Size(6)    

FddimibSMTEntry  
SEQUENCE    
  fddimibSMTIndex INTEGER
  fddimibSMTStationId FddiSMTStationIdType
  fddimibSMTOpVersionId INTEGER
  fddimibSMTHiVersionId INTEGER
  fddimibSMTLoVersionId INTEGER
  fddimibSMTUserData OCTET STRING
  fddimibSMTMIBVersionId INTEGER
  fddimibSMTMACCts INTEGER
  fddimibSMTNonMasterCts INTEGER
  fddimibSMTMasterCts INTEGER
  fddimibSMTAvailablePaths INTEGER
  fddimibSMTConfigCapabilities INTEGER
  fddimibSMTConfigPolicy INTEGER
  fddimibSMTConnectionPolicy INTEGER
  fddimibSMTTNotify INTEGER
  fddimibSMTStatRptPolicy INTEGER
  fddimibSMTTraceMaxExpiration FddiTimeMilli
  fddimibSMTBypassPresent INTEGER
  fddimibSMTECMState INTEGER
  fddimibSMTCFState INTEGER
  fddimibSMTRemoteDisconnectFlag INTEGER
  fddimibSMTStationStatus INTEGER
  fddimibSMTPeerWrapFlag INTEGER
  fddimibSMTTimeStamp FddiTimeMilli
  fddimibSMTTransitionTimeStamp FddiTimeMilli
  fddimibSMTStationAction INTEGER

FddimibMACEntry  
SEQUENCE    
  fddimibMACSMTIndex INTEGER
  fddimibMACIndex INTEGER
  fddimibMACIfIndex INTEGER
  fddimibMACFrameStatusFunctions INTEGER
  fddimibMACTMaxCapability FddiTimeNano
  fddimibMACTVXCapability FddiTimeNano
  fddimibMACAvailablePaths INTEGER
  fddimibMACCurrentPath INTEGER
  fddimibMACUpstreamNbr FddiMACLongAddressType
  fddimibMACDownstreamNbr FddiMACLongAddressType
  fddimibMACOldUpstreamNbr FddiMACLongAddressType
  fddimibMACOldDownstreamNbr FddiMACLongAddressType
  fddimibMACDupAddressTest INTEGER
  fddimibMACRequestedPaths INTEGER
  fddimibMACDownstreamPORTType INTEGER
  fddimibMACSMTAddress FddiMACLongAddressType
  fddimibMACTReq FddiTimeNano
  fddimibMACTNeg FddiTimeNano
  fddimibMACTMax FddiTimeNano
  fddimibMACTvxValue FddiTimeNano
  fddimibMACFrameCts Counter
  fddimibMACCopiedCts Counter
  fddimibMACTransmitCts Counter
  fddimibMACErrorCts Counter
  fddimibMACLostCts Counter
  fddimibMACFrameErrorThreshold INTEGER
  fddimibMACFrameErrorRatio INTEGER
  fddimibMACRMTState INTEGER
  fddimibMACDaFlag INTEGER
  fddimibMACUnaDaFlag INTEGER
  fddimibMACFrameErrorFlag INTEGER
  fddimibMACMAUnitdataAvailable INTEGER
  fddimibMACHardwarePresent INTEGER
  fddimibMACMAUnitdataEnable INTEGER

FddimibMACCountersEntry  
SEQUENCE    
  fddimibMACTokenCts Counter
  fddimibMACTvxExpiredCts Counter
  fddimibMACNotCopiedCts Counter
  fddimibMACLateCts Counter
  fddimibMACRingOpCts Counter
  fddimibMACNotCopiedRatio INTEGER
  fddimibMACNotCopiedFlag INTEGER
  fddimibMACNotCopiedThreshold INTEGER

FddimibPATHEntry  
SEQUENCE    
  fddimibPATHSMTIndex INTEGER
  fddimibPATHIndex INTEGER
  fddimibPATHTVXLowerBound FddiTimeNano
  fddimibPATHTMaxLowerBound FddiTimeNano
  fddimibPATHMaxTReq FddiTimeNano

FddimibPATHConfigEntry  
SEQUENCE    
  fddimibPATHConfigSMTIndex INTEGER
  fddimibPATHConfigPATHIndex INTEGER
  fddimibPATHConfigTokenOrder INTEGER
  fddimibPATHConfigResourceType INTEGER
  fddimibPATHConfigResourceIndex INTEGER
  fddimibPATHConfigCurrentPath INTEGER

FddimibPORTEntry  
SEQUENCE    
  fddimibPORTSMTIndex INTEGER
  fddimibPORTIndex INTEGER
  fddimibPORTMyType INTEGER
  fddimibPORTNeighborType INTEGER
  fddimibPORTConnectionPolicies INTEGER
  fddimibPORTMACIndicated INTEGER
  fddimibPORTCurrentPath INTEGER
  fddimibPORTRequestedPaths OCTET STRING
  fddimibPORTMACPlacement FddiResourceId
  fddimibPORTAvailablePaths INTEGER
  fddimibPORTPMDClass INTEGER
  fddimibPORTConnectionCapabilities INTEGER
  fddimibPORTBSFlag INTEGER
  fddimibPORTLCTFailCts Counter
  fddimibPORTLerEstimate INTEGER
  fddimibPORTLemRejectCts Counter
  fddimibPORTLemCts Counter
  fddimibPORTLerCutoff INTEGER
  fddimibPORTLerAlarm INTEGER
  fddimibPORTConnectState INTEGER
  fddimibPORTPCMState INTEGER
  fddimibPORTPCWithhold INTEGER
  fddimibPORTLerFlag INTEGER
  fddimibPORTHardwarePresent INTEGER
  fddimibPORTAction INTEGER

Defined Values

fddi 1.3.6.1.2.1.10.15
OBJECT IDENTIFIER    

fddimib 1.3.6.1.2.1.10.15.73
OBJECT IDENTIFIER    

fddimibSMT 1.3.6.1.2.1.10.15.73.1
OBJECT IDENTIFIER    

fddimibMAC 1.3.6.1.2.1.10.15.73.2
OBJECT IDENTIFIER    

fddimibMACCounters 1.3.6.1.2.1.10.15.73.3
OBJECT IDENTIFIER    

fddimibPATH 1.3.6.1.2.1.10.15.73.4
OBJECT IDENTIFIER    

fddimibPORT 1.3.6.1.2.1.10.15.73.5
OBJECT IDENTIFIER    

fddimibSMTNumber 1.3.6.1.2.1.10.15.73.1.1
The number of SMT implementations (regardless of their current state) on this network management application entity. The value for this variable must remain constant at least from one re- initialization of the entity's network management system to the next re-initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibSMTTable 1.3.6.1.2.1.10.15.73.1.2
A list of SMT entries. The number of entries shall not exceed the value of fddimibSMTNumber.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FddimibSMTEntry

fddimibSMTEntry 1.3.6.1.2.1.10.15.73.1.2.1
An SMT entry containing information common to a given SMT.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FddimibSMTEntry  

fddimibSMTIndex 1.3.6.1.2.1.10.15.73.1.2.1.1
A unique value for each SMT. The value for each SMT must remain constant at least from one re- initialization of the entity's network management system to the next re-initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibSMTStationId 1.3.6.1.2.1.10.15.73.1.2.1.2
Used to uniquely identify an FDDI station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiSMTStationIdType  

fddimibSMTOpVersionId 1.3.6.1.2.1.10.15.73.1.2.1.3
The version that this station is using for its operation (refer to ANSI 7.1.2.2). The value of this variable is 2 for this SMT revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibSMTHiVersionId 1.3.6.1.2.1.10.15.73.1.2.1.4
The highest version of SMT that this station supports (refer to ANSI 7.1.2.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibSMTLoVersionId 1.3.6.1.2.1.10.15.73.1.2.1.5
The lowest version of SMT that this station supports (refer to ANSI 7.1.2.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibSMTUserData 1.3.6.1.2.1.10.15.73.1.2.1.6
This variable contains 32 octets of user defined information. The information shall be an ASCII string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(32)  

fddimibSMTMIBVersionId 1.3.6.1.2.1.10.15.73.1.2.1.7
The version of the FDDI MIB of this station. The value of this variable is 1 for this SMT revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibSMTMACCts 1.3.6.1.2.1.10.15.73.1.2.1.8
The number of MACs in this station or concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fddimibSMTNonMasterCts 1.3.6.1.2.1.10.15.73.1.2.1.9
The value of this variable is the number of A, B, and S ports in this station or concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2  

fddimibSMTMasterCts 1.3.6.1.2.1.10.15.73.1.2.1.10
The number of M Ports in a node. If the node is not a concentrator, the value of the variable is zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fddimibSMTAvailablePaths 1.3.6.1.2.1.10.15.73.1.2.1.11
A value that indicates the PATH types available in the station. The value is a sum. This value initially takes the value zero, then for each type of PATH that this node has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 For example, a station having Primary and Local PATHs available would have a value of 5 (2**0 + 2**2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

fddimibSMTConfigCapabilities 1.3.6.1.2.1.10.15.73.1.2.1.12
A value that indicates the configuration capabilities of a node. The 'Hold Available' bit indicates the support of the optional Hold Function, which is controlled by fddiSMTConfigPolicy. The 'CF-Wrap-AB' bit indicates that the station has the capability of performing a wrap_ab (refer to ANSI SMT 9.7.2.2). The value is a sum. This value initially takes the value zero, then for each of the configuration policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power holdAvailable 0 CF-Wrap-AB 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

fddimibSMTConfigPolicy 1.3.6.1.2.1.10.15.73.1.2.1.13
A value that indicates the configuration policies currently desired in a node. 'Hold' is one of the terms used for the Hold Flag, an optional ECM flag used to enable the optional Hold policy. The value is a sum. This value initially takes the value zero, then for each of the configuration policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power configurationhold 0
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

fddimibSMTConnectionPolicy 1.3.6.1.2.1.10.15.73.1.2.1.14
A value representing the connection policies in effect in a node. A station sets the corresponding bit for each of the connection types that it rejects. The letter designations, X and Y, in the 'rejectX-Y' names have the following significance: X represents the PC-Type of the local PORT and Y represents the PC_Type of the adjacent PORT (PC_Neighbor). The evaluation of Connection- Policy (PC-Type, PC-Neighbor) is done to determine the setting of T- Val(3) in the PC-Signalling sequence (refer to ANSI 9.6.3). Note that Bit 15, (rejectM-M), is always set and cannot be cleared. The value is a sum. This value initially takes the value zero, then for each of the connection policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power rejectA-A 0 rejectA-B 1 rejectA-S 2 rejectA-M 3 rejectB-A 4 rejectB-B 5 rejectB-S 6 rejectB-M 7 rejectS-A 8 rejectS-B 9 rejectS-S 10 rejectS-M 11 rejectM-A 12 rejectM-B 13 rejectM-S 14 rejectM-M 15
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 32768..65535  

fddimibSMTTNotify 1.3.6.1.2.1.10.15.73.1.2.1.15
The timer, expressed in seconds, used in the Neighbor Notification protocol. It has a range of 2 seconds to 30 seconds, and its default value is 30 seconds (refer to ANSI SMT 8.2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..30  

fddimibSMTStatRptPolicy 1.3.6.1.2.1.10.15.73.1.2.1.16
If true, indicates that the node will generate Status Reporting Frames for its implemented events and conditions. It has an initial value of true. This variable determines the value of the SR_Enable Flag (refer to ANSI SMT 8.3.2.1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibSMTTraceMaxExpiration 1.3.6.1.2.1.10.15.73.1.2.1.17
Reference Trace_Max (refer to ANSI SMT 9.4.4.2.2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  FddiTimeMilli  

fddimibSMTBypassPresent 1.3.6.1.2.1.10.15.73.1.2.1.18
A flag indicating if the station has a bypass on its AB port pair.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibSMTECMState 1.3.6.1.2.1.10.15.73.1.2.1.19
Indicates the current state of the ECM state machine (refer to ANSI SMT 9.5.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ec0(1), ec1(2), ec2(3), ec3(4), ec4(5), ec5(6), ec6(7), ec7(8)  

fddimibSMTCFState 1.3.6.1.2.1.10.15.73.1.2.1.20
The attachment configuration for the station or concentrator (refer to ANSI SMT 9.7.2.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cf0(1), cf1(2), cf2(3), cf3(4), cf4(5), cf5(6), cf6(7), cf7(8), cf8(9), cf9(10), cf10(11), cf11(12), cf12(13)  

fddimibSMTRemoteDisconnectFlag 1.3.6.1.2.1.10.15.73.1.2.1.21
A flag indicating that the station was remotely disconnected from the network as a result of receiving an fddiSMTAction, disconnect (refer to ANSI SMT 6.4.5.3) in a Parameter Management Frame. A station requires a Connect Action to rejoin and clear the flag (refer to ANSI SMT 6.4.5.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibSMTStationStatus 1.3.6.1.2.1.10.15.73.1.2.1.22
The current status of the primary and secondary paths within this station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER concatenated(1), separated(2), thru(3)  

fddimibSMTPeerWrapFlag 1.3.6.1.2.1.10.15.73.1.2.1.23
This variable assumes the value of the PeerWrapFlag in CFM (refer to ANSI SMT 9.7.2.4.4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibSMTTimeStamp 1.3.6.1.2.1.10.15.73.1.2.1.24
This variable assumes the value of TimeStamp (refer to ANSI SMT 8.3.2.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiTimeMilli  

fddimibSMTTransitionTimeStamp 1.3.6.1.2.1.10.15.73.1.2.1.25
This variable assumes the value of TransitionTimeStamp (refer to ANSI SMT 8.3.2.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiTimeMilli  

fddimibSMTStationAction 1.3.6.1.2.1.10.15.73.1.2.1.26
This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows: other(1): Results in an appropriate error. connect(2): Generates a Connect signal to ECM to begin a connection sequence. See ANSI Ref 9.4.2. disconnect(3): Generates a Disconnect signal to ECM. see ANSI Ref 9.4.2. path-Test(4): Initiates a station Path_Test. The Path_Test variable (see ANSI Ref 9.4.1) is set to 'Testing'. The results of this action are not specified in this standard. self-Test(5): Initiates a station Self_Test. The results of this action are not specified in this standard. disable-a(6): Causes a PC_Disable on the A port if the A port mode is peer. disable-b(7): Causes a PC_Disable on the B port if the B port mode is peer. disable-m(8): Causes a PC_Disable on all M ports. Attempts to set this object to all other values results in an appropriate error. The result of setting this variable to path-Test(4) or self- Test(5) is implementation-specific.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), connect(2), disconnect(3), path-Test(4), self-Test(5), disable-a(6), disable-b(7), disable-m(8)  

fddimibMACNumber 1.3.6.1.2.1.10.15.73.2.1
The total number of MAC implementations (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibMACTable 1.3.6.1.2.1.10.15.73.2.2
A list of MAC entries. The number of entries shall not exceed the value of fddimibMACNumber.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FddimibMACEntry

fddimibMACEntry 1.3.6.1.2.1.10.15.73.2.2.1
A MAC entry containing information common to a given MAC.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FddimibMACEntry  

fddimibMACSMTIndex 1.3.6.1.2.1.10.15.73.2.2.1.1
The value of the SMT index associated with this MAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibMACIndex 1.3.6.1.2.1.10.15.73.2.2.1.2
Index variable for uniquely identifying the MAC object instances, which is the same as the corresponding resource index in SMT.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibMACIfIndex 1.3.6.1.2.1.10.15.73.2.2.1.3
The value of the MIB-II ifIndex corresponding to this MAC. If none is applicable, 0 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibMACFrameStatusFunctions 1.3.6.1.2.1.10.15.73.2.2.1.4
Indicates the MAC's optional Frame Status processing functions. The value is a sum. This value initially takes the value zero, then for each function present, 2 raised to a power is added to the sum. The powers are according to the following table: function Power fs-repeating 0 fs-setting 1 fs-clearing 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

fddimibMACTMaxCapability 1.3.6.1.2.1.10.15.73.2.2.1.5
Indicates the maximum time value of fddiMACTMax that this MAC can support.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiTimeNano  

fddimibMACTVXCapability 1.3.6.1.2.1.10.15.73.2.2.1.6
Indicates the maximum time value of fddiMACTvxValue that this MAC can support.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiTimeNano  

fddimibMACAvailablePaths 1.3.6.1.2.1.10.15.73.2.2.1.7
Indicates the paths available for this MAC (refer to ANSI SMT 9.7.7). The value is a sum. This value initially takes the value zero, then for each type of PATH that this MAC has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

fddimibMACCurrentPath 1.3.6.1.2.1.10.15.73.2.2.1.8
Indicates the Path into which this MAC is currently inserted (refer to ANSI 9.7.7).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(1), local(2), secondary(3), primary(4), concatenated(5), thru(6)  

fddimibMACUpstreamNbr 1.3.6.1.2.1.10.15.73.2.2.1.9
The MAC's upstream neighbor's long individual MAC address. It has an initial value of the SMT- Unknown-MAC Address and is only modified as specified by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1 and 8.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiMACLongAddressType  

fddimibMACDownstreamNbr 1.3.6.1.2.1.10.15.73.2.2.1.10
The MAC's downstream neighbor's long individual MAC address. It has an initial value of the SMT- Unknown-MAC Address and is only modified as specified by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1 and 8.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiMACLongAddressType  

fddimibMACOldUpstreamNbr 1.3.6.1.2.1.10.15.73.2.2.1.11
The previous value of the MAC's upstream neighbor's long individual MAC address. It has an initial value of the SMT-Unknown- MAC Address and is only modified as specified by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1 and 8.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiMACLongAddressType  

fddimibMACOldDownstreamNbr 1.3.6.1.2.1.10.15.73.2.2.1.12
The previous value of the MAC's downstream neighbor's long individual MAC address. It has an initial value of the SMT- Unknown-MAC Address and is only modified as specified by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1 and 8.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiMACLongAddressType  

fddimibMACDupAddressTest 1.3.6.1.2.1.10.15.73.2.2.1.13
The Duplicate Address Test flag, Dup_Addr_Test (refer to ANSI 8.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), pass(2), fail(3)  

fddimibMACRequestedPaths 1.3.6.1.2.1.10.15.73.2.2.1.14
List of permitted Paths which specifies the Path(s) into which the MAC may be inserted (refer to ansi SMT 9.7). The value is a sum which represents the individual paths that are desired. This value initially takes the value zero, then for each type of PATH that this node is, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power local 0 secondary-alternate 1 primary-alternate 2 concatenated-alternate 3 secondary-preferred 4 primary-preferred 5 concatenated-preferred 6 thru 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fddimibMACDownstreamPORTType 1.3.6.1.2.1.10.15.73.2.2.1.15
Indicates the PC-Type of the first port that is downstream of this MAC (the exit port).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER a(1), b(2), s(3), m(4), none(5)  

fddimibMACSMTAddress 1.3.6.1.2.1.10.15.73.2.2.1.16
The 48-bit individual address of the MAC used for SMT frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiMACLongAddressType  

fddimibMACTReq 1.3.6.1.2.1.10.15.73.2.2.1.17
This variable is the T_Req_value passed to the MAC. Without having detected a duplicate, the time value of this variable shall assume the maximum supported time value which is less than or equal to the time value of fddiPATHMaxT-Req. When a MAC has an address detected as a duplicate, it may use a time value for this variable greater than the time value of fddiPATHTMaxLowerBound. A station shall cause claim when the new T_Req may cause the value of T_Neg to change in the claim process, (i.e., time value new T_Req < T_Neg, or old T_Req = T_Neg).
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiTimeNano  

fddimibMACTNeg 1.3.6.1.2.1.10.15.73.2.2.1.18
It is reported as a FddiTimeNano number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiTimeNano  

fddimibMACTMax 1.3.6.1.2.1.10.15.73.2.2.1.19
This variable is the T_Max_value passed to the MAC. The time value of this variable shall assume the minimum supported time value which is greater than or equal to the time value of fddiPATHT- MaxLowerBound
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiTimeNano  

fddimibMACTvxValue 1.3.6.1.2.1.10.15.73.2.2.1.20
This variable is the TVX_value passed to the MAC. The time value of this variable shall assume the minimum supported time value which is greater than or equal to the time value of fddiPATHTVXLowerBound.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiTimeNano  

fddimibMACFrameCts 1.3.6.1.2.1.10.15.73.2.2.1.21
A count of the number of frames received by this MAC (refer to ANSI MAC 7.5.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACCopiedCts 1.3.6.1.2.1.10.15.73.2.2.1.22
A count that should as closely as possible match the number of frames addressed to (A bit set) and successfully copied into the station's receive buffers (C bit set) by this MAC (refer to ANSI MAC 7.5). Note that this count does not include MAC frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACTransmitCts 1.3.6.1.2.1.10.15.73.2.2.1.23
A count that should as closely as possible match the number of frames transmitted by this MAC (refer to ANSI MAC 7.5). Note that this count does not include MAC frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACErrorCts 1.3.6.1.2.1.10.15.73.2.2.1.24
A count of the number of frames that were detected in error by this MAC that had not been detected in error by another MAC (refer to ANSI MAC 7.5.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACLostCts 1.3.6.1.2.1.10.15.73.2.2.1.25
A count of the number of instances that this MAC detected a format error during frame reception such that the frame was stripped (refer to ANSI MAC 7.5.3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACFrameErrorThreshold 1.3.6.1.2.1.10.15.73.2.2.1.26
A threshold for determining when a MAC Condition report (see ANSI 8.3.1.1) shall be generated. Stations not supporting variable thresholds shall have a value of 0 and a range of (0..0).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibMACFrameErrorRatio 1.3.6.1.2.1.10.15.73.2.2.1.27
This variable is the value of the ratio, ((delta fddiMACLostCts + delta fddiMACErrorCts) / (delta fddiMACFrameCts + delta fddiMACLostCts )) * 2**16
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibMACRMTState 1.3.6.1.2.1.10.15.73.2.2.1.28
Indicates the current state of the RMT State Machine (refer to ANSI 10.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rm0(1), rm1(2), rm2(3), rm3(4), rm4(5), rm5(6), rm6(7), rm7(8)  

fddimibMACDaFlag 1.3.6.1.2.1.10.15.73.2.2.1.29
The RMT flag Duplicate Address Flag, DA_Flag (refer to ANSI 10.2.1.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibMACUnaDaFlag 1.3.6.1.2.1.10.15.73.2.2.1.30
A flag, UNDA_Flag (refer to ANSI 8.2.2.1), set when the upstream neighbor reports a duplicate address condition. Cleared when the condition clears.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibMACFrameErrorFlag 1.3.6.1.2.1.10.15.73.2.2.1.31
Indicates the MAC Frame Error Condition is present when set. Cleared when the condition clears and on station initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibMACMAUnitdataAvailable 1.3.6.1.2.1.10.15.73.2.2.1.32
This variable shall take on the value of the MAC_Avail flag defined in RMT.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibMACHardwarePresent 1.3.6.1.2.1.10.15.73.2.2.1.33
This variable indicates the presence of underlying hardware support for this MAC object. If the value of this object is false(2), the reporting of the objects in this entry may be handled in an implementation-specific manner.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibMACMAUnitdataEnable 1.3.6.1.2.1.10.15.73.2.2.1.34
This variable determines the value of the MA_UNITDATA_Enable flag in RMT. The default and initial value of this flag is true(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibMACCountersTable 1.3.6.1.2.1.10.15.73.3.1
A list of MAC Counters entries. The number of entries shall not exceed the value of fddimibMACNumber.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FddimibMACCountersEntry

fddimibMACCountersEntry 1.3.6.1.2.1.10.15.73.3.1.1
A MAC Counters entry containing information common to a given MAC.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FddimibMACCountersEntry  

fddimibMACTokenCts 1.3.6.1.2.1.10.15.73.3.1.1.1
A count that should as closely as possible match the number of times the station has received a token (total of non-restricted and restricted) on this MAC (see ANSI MAC 7.4). This count is valuable for determination of network load.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACTvxExpiredCts 1.3.6.1.2.1.10.15.73.3.1.1.2
A count that should as closely as possible match the number of times that TVX has expired.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACNotCopiedCts 1.3.6.1.2.1.10.15.73.3.1.1.3
A count that should as closely as possible match the number of frames that were addressed to this MAC but were not copied into its receive buffers (see ANSI MAC 7.5). For example, this might occur due to local buffer congestion. Because of implementation considerations, this count may not match the actual number of frames not copied. It is not a requirement that this count be exact. Note that this count does not include MAC frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACLateCts 1.3.6.1.2.1.10.15.73.3.1.1.4
A count that should as closely as possible match the number of TRT expirations since this MAC was reset or a token was received (refer to ANSI MAC 7.4.5).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACRingOpCts 1.3.6.1.2.1.10.15.73.3.1.1.5
The count of the number of times the ring has entered the 'Ring_Operational' state from the 'Ring Not Operational' state. This count is updated when a SM_MA_STATUS.Indication of a change in the Ring_Operational status occurs (refer to ANSI 6.1.4). Because of implementation considerations, this count may be less than the actual RingOp_Ct. It is not a requirement that this count be exact.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibMACNotCopiedRatio 1.3.6.1.2.1.10.15.73.3.1.1.6
This variable is the value of the ratio: (delta fddiMACNotCopiedCts / (delta fddiMACCopiedCts + delta fddiMACNotCopiedCts )) * 2**16
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibMACNotCopiedFlag 1.3.6.1.2.1.10.15.73.3.1.1.7
Indicates that the Not Copied condition is present when read as true(1). Set to false(2) when the condition clears and on station initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibMACNotCopiedThreshold 1.3.6.1.2.1.10.15.73.3.1.1.8
A threshold for determining when a MAC condition report shall be generated. Stations not supporting variable thresholds shall have a value of 0 and a range of (0..0).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibPATHNumber 1.3.6.1.2.1.10.15.73.4.1
The total number of PATHs possible (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibPATHTable 1.3.6.1.2.1.10.15.73.4.2
A list of PATH entries. The number of entries shall not exceed the value of fddimibPATHNumber.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FddimibPATHEntry

fddimibPATHEntry 1.3.6.1.2.1.10.15.73.4.2.1
A PATH entry containing information common to a given PATH.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FddimibPATHEntry  

fddimibPATHSMTIndex 1.3.6.1.2.1.10.15.73.4.2.1.1
The value of the SMT index associated with this PATH.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibPATHIndex 1.3.6.1.2.1.10.15.73.4.2.1.2
Index variable for uniquely identifying the primary, secondary and local PATH object instances. Local PATH object instances are represented with integer values 3 to 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibPATHTVXLowerBound 1.3.6.1.2.1.10.15.73.4.2.1.3
Specifies the minimum time value of fddiMACTvxValue that shall be used by any MAC that is configured in this path. The operational value of fddiMACTvxValue is managed by setting this variable. This variable has the time value range of: 0 < fddimibPATHTVXLowerBound < fddimibPATHMaxTReq Changes to this variable shall either satisfy the time value relationship: fddimibPATHTVXLowerBound <= fddimibMACTVXCapability of each of the MACs currently on the path, or be considered out of range. The initial value of fddimibPATHTVXLowerBound shall be 2500 nsec (2.5 ms).
Status: mandatory Access: read-write
OBJECT-TYPE    
  FddiTimeNano  

fddimibPATHTMaxLowerBound 1.3.6.1.2.1.10.15.73.4.2.1.4
Specifies the minimum time value of fddiMACTMax that shall be used by any MAC that is configured in this path. The operational value of fddiMACTMax is managed by setting this variable. This variable has the time value range of: fddimibPATHMaxTReq <= fddimibPATHTMaxLowerBound and an absolute time value range of: 10000nsec (10 msec) <= fddimibPATHTMaxLowerBound Changes to this variable shall either satisfy the time value relationship: fddimibPATHTMaxLowerBound < fddimibMACTMaxCapability of each of the MACs currently on the path, or be considered out of range. The initial value of fddimibPATHTMaxLowerBound shall be 165000 nsec (165 msec).
Status: mandatory Access: read-write
OBJECT-TYPE    
  FddiTimeNano  

fddimibPATHMaxTReq 1.3.6.1.2.1.10.15.73.4.2.1.5
Specifies the maximum time value of fddiMACT-Req that shall be used by any MAC that is configured in this path. The operational value of fddiMACT- Req is managed by setting this variable. This variable has the time value range of: fddimibPATHTVXLowerBound < fddimibPATHMaxTReq <= fddimibPATHTMaxLowerBound. The default value of fddimibPATHMaxTReq is 165000 nsec (165 msec).
Status: mandatory Access: read-write
OBJECT-TYPE    
  FddiTimeNano  

fddimibPATHConfigTable 1.3.6.1.2.1.10.15.73.4.3
A table of Path configuration entries. This table lists all the resources that may be in this Path.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FddimibPATHConfigEntry

fddimibPATHConfigEntry 1.3.6.1.2.1.10.15.73.4.3.1
A collection of objects containing information for a given PATH Configuration entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FddimibPATHConfigEntry  

fddimibPATHConfigSMTIndex 1.3.6.1.2.1.10.15.73.4.3.1.1
The value of the SMT index associated with this configuration entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibPATHConfigPATHIndex 1.3.6.1.2.1.10.15.73.4.3.1.2
The value of the PATH resource index associated with this configuration entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibPATHConfigTokenOrder 1.3.6.1.2.1.10.15.73.4.3.1.3
An object associated with Token order for this entry. Thus if the token passes resources a, b, c and d, in that order, then the value of this object for these resources would be 1, 2, 3 and 4 respectively.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibPATHConfigResourceType 1.3.6.1.2.1.10.15.73.4.3.1.4
The type of resource associated with this configuration entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER mac(2), port(4)  

fddimibPATHConfigResourceIndex 1.3.6.1.2.1.10.15.73.4.3.1.5
The value of the SMT resource index used to refer to the instance of this MAC or Port resource.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibPATHConfigCurrentPath 1.3.6.1.2.1.10.15.73.4.3.1.6
The current insertion status for this resource on this Path.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(1), local(2), secondary(3), primary(4), concatenated(5), thru(6)  

fddimibPORTNumber 1.3.6.1.2.1.10.15.73.5.1
The total number of PORT implementations (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

fddimibPORTTable 1.3.6.1.2.1.10.15.73.5.2
A list of PORT entries. The number of entries shall not exceed the value of fddimibPORTNumber.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FddimibPORTEntry

fddimibPORTEntry 1.3.6.1.2.1.10.15.73.5.2.1
A PORT entry containing information common to a given PORT.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FddimibPORTEntry  

fddimibPORTSMTIndex 1.3.6.1.2.1.10.15.73.5.2.1.1
The value of the SMT index associated with this PORT.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibPORTIndex 1.3.6.1.2.1.10.15.73.5.2.1.2
A unique value for each PORT within a given SMT, which is the same as the corresponding resource index in SMT. The value for each PORT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

fddimibPORTMyType 1.3.6.1.2.1.10.15.73.5.2.1.3
The value of the PORT's PC_Type (refer to ANSI 9.4.1, and 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER a(1), b(2), s(3), m(4), none(5)  

fddimibPORTNeighborType 1.3.6.1.2.1.10.15.73.5.2.1.4
The type of the remote PORT as determined in PCM. This variable has an initial value of none, and is only modified in PC_RCode(3)_Actions (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER a(1), b(2), s(3), m(4), none(5)  

fddimibPORTConnectionPolicies 1.3.6.1.2.1.10.15.73.5.2.1.5
A value representing the PORT's connection policies desired in the node. The value of pc- mac-lct is a term used in the PC_MAC_LCT Flag (see 9.4.3.2). The value of pc-mac-loop is a term used in the PC_MAC_Loop Flag. The value is a sum. This value initially takes the value zero, then for each PORT policy, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power pc-mac-lct 0 pc-mac-loop 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

fddimibPORTMACIndicated 1.3.6.1.2.1.10.15.73.5.2.1.6
The indications (T_Val(9), R_Val(9)) in PC- Signalling, of the intent to place a MAC in the output token path to a PORT (refer to ANSI SMT 9.6.3.2.).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tVal9FalseRVal9False(1), tVal9FalseRVal9True(2), tVal9TrueRVal9False(3), tVal9TrueRVal9True(4)  

fddimibPORTCurrentPath 1.3.6.1.2.1.10.15.73.5.2.1.7
Indicates the Path(s) into which this PORT is currently inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ce0(1), ce1(2), ce2(3), ce3(4), ce4(5), ce5(6)  

fddimibPORTRequestedPaths 1.3.6.1.2.1.10.15.73.5.2.1.8
This variable is a list of permitted Paths where each list element defines the Port's permitted Paths. The first octet corresponds to 'none', the second octet to 'tree', and the third octet to 'peer'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

fddimibPORTMACPlacement 1.3.6.1.2.1.10.15.73.5.2.1.9
Indicates the MAC, if any, whose transmit path exits the station via this PORT. The value shall be zero if there is no MAC associated with the PORT. Otherwise, the MACIndex of the MAC will be the value of the variable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FddiResourceId  

fddimibPORTAvailablePaths 1.3.6.1.2.1.10.15.73.5.2.1.10
Indicates the Paths which are available to this Port. In the absence of faults, the A and B Ports will always have both the Primary and Secondary Paths available. The value is a sum. This value initially takes the value zero, then for each type of PATH that this port has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

fddimibPORTPMDClass 1.3.6.1.2.1.10.15.73.5.2.1.11
This variable indicates the type of PMD entity associated with this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER multimode(1), single-mode1(2), single-mode2(3), sonet(4), low-cost-fiber(5), twisted-pair(6), unknown(7), unspecified(8)  

fddimibPORTConnectionCapabilities 1.3.6.1.2.1.10.15.73.5.2.1.12
A value that indicates the connection capabilities of the port. The pc-mac-lct bit indicates that the station has the capability of setting the PC_MAC_LCT Flag. The pc-mac-loop bit indicates that the station has the capability of setting the PC_MAC_Loop Flag (refer to ANSI 9.4.3.2). The value is a sum. This value initially takes the value zero, then for each capability that this port has, 2 raised to a power is added to the sum. The powers are according to the following table: capability Power pc-mac-lct 0 pc-mac-loop 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

fddimibPORTBSFlag 1.3.6.1.2.1.10.15.73.5.2.1.13
This variable assumes the value of the BS_Flag (refer to ANSI SMT 9.4.3.3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibPORTLCTFailCts 1.3.6.1.2.1.10.15.73.5.2.1.14
The count of the consecutive times the link confidence test (LCT) has failed during connection management (refer to ANSI 9.4.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibPORTLerEstimate 1.3.6.1.2.1.10.15.73.5.2.1.15
A long term average link error rate. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the base 10 logarithm (refer to ANSI SMT 9.4.7.5.).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 4..15  

fddimibPORTLemRejectCts 1.3.6.1.2.1.10.15.73.5.2.1.16
A link error monitoring count of the times that a link has been rejected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibPORTLemCts 1.3.6.1.2.1.10.15.73.5.2.1.17
The aggregate link error monitor error count, set to zero only on station initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddimibPORTLerCutoff 1.3.6.1.2.1.10.15.73.5.2.1.18
The link error rate estimate at which a link connection will be broken. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the base 10 logarithm (default of 7).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..15  

fddimibPORTLerAlarm 1.3.6.1.2.1.10.15.73.5.2.1.19
The link error rate estimate at which a link connection will generate an alarm. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the base 10 logarithm of the estimate (default of 8).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..15  

fddimibPORTConnectState 1.3.6.1.2.1.10.15.73.5.2.1.20
An indication of the connect state of this PORT and is equal to the value of Connect_State (refer to ANSI 9.4.1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), connecting(2), standby(3), active(4)  

fddimibPORTPCMState 1.3.6.1.2.1.10.15.73.5.2.1.21
The state of this Port's PCM state machine refer to ANSI SMT 9.6.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pc0(1), pc1(2), pc2(3), pc3(4), pc4(5), pc5(6), pc6(7), pc7(8), pc8(9), pc9(10)  

fddimibPORTPCWithhold 1.3.6.1.2.1.10.15.73.5.2.1.22
The value of PC_Withhold (refer to ANSI SMT 9.4.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), m-m(2), otherincompatible(3), pathnotavailable(4)  

fddimibPORTLerFlag 1.3.6.1.2.1.10.15.73.5.2.1.23
The condition becomes active when the value of fddiPORTLerEstimate is less than or equal to fddiPORTLerAlarm. This will be reported with the Status Report Frames (SRF) (refer to ANSI SMT 7.2.7 and 8.3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibPORTHardwarePresent 1.3.6.1.2.1.10.15.73.5.2.1.24
This variable indicates the presence of underlying hardware support for this Port object. If the value of this object is false(2), the reporting of the objects in this entry may be handled in an implementation-specific manner.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

fddimibPORTAction 1.3.6.1.2.1.10.15.73.5.2.1.25
Causes a Control signal to be generated with a control_action of 'Signal' and the 'variable' parameter set with the appropriate value (i.e., PC_Maint, PC_Enable, PC_Disable, PC_Start, or PC_Stop) (refer to ANSI 9.4.2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), maintPORT(2), enablePORT(3), disablePORT(4), startPORT(5), stopPORT(6)