FDDI-CONCENTRATOR-MIB

File: FDDI-CONCENTRATOR-MIB.mib (18065 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

enterprises IpAddress Counter
OBJECT-TYPE

Defined Types

ConcentratorPORTEntry  
SEQUENCE    
  concentratorPORTSMTIndex INTEGER
  concentratorPORTIndex INTEGER
  concentratorPORTType INTEGER
  concentratorPORTStatus INTEGER

ConcentratorVERSIONSlotEntry  
SEQUENCE    
  concentratorVERSIONSlotIndex INTEGER
  concentratorVERSIONSlotSerialNumber STRING Size(6)
  concentratorVERSIONSlotId INTEGER
  concentratorVERSIONSlotHrdwrStatus INTEGER
  concentratorVERSIONSlotRevision INTEGER

Defined Values

fibronics 1.3.6.1.4.1.22
OBJECT IDENTIFIER    

fddiConcentrator 1.3.6.1.4.1.22.70
OBJECT IDENTIFIER    

concentratorPORT 1.3.6.1.4.1.22.70.1
OBJECT IDENTIFIER    

concentratorPROCESSOR 1.3.6.1.4.1.22.70.2
OBJECT IDENTIFIER    

concentratorMEMORY 1.3.6.1.4.1.22.70.3
OBJECT IDENTIFIER    

concentratorSERIALPORT 1.3.6.1.4.1.22.70.4
OBJECT IDENTIFIER    

concentratorVERSIONS 1.3.6.1.4.1.22.70.5
OBJECT IDENTIFIER    

concentratorPOWER 1.3.6.1.4.1.22.70.6
OBJECT IDENTIFIER    

concentratorTRAPS 1.3.6.1.4.1.22.70.7
OBJECT IDENTIFIER    

concentratorIDENTIFIER 1.3.6.1.4.1.22.70.8
OBJECT IDENTIFIER    

concentratorTRAFFIC 1.3.6.1.4.1.22.70.9
OBJECT IDENTIFIER    

concentratorPORTTable 1.3.6.1.4.1.22.70.1.1
A list of PORT entries. The number of entries is given by the value of the snmpFddiPORTNumber (see standard fddi.
OBJECT-TYPE    
  SEQUENCE OF  
    ConcentratorPORTEntry

concentratorPORTEntry 1.3.6.1.4.1.22.70.1.1.1
A PORT entry containing information common to a given PORT.
OBJECT-TYPE    
  ConcentratorPORTEntry  

concentratorPORTSMTIndex 1.3.6.1.4.1.22.70.1.1.1.1
The value of the SMT index associated with this PORT.
OBJECT-TYPE    
  INTEGER 1..65535  

concentratorPORTIndex 1.3.6.1.4.1.22.70.1.1.1.2
A unique value for each PORT within a given SMT. Its value ranges between 1 and the sum of the values of concentratorSMTNonMasterCt { concentratorSMTEntry 6 } and concentratorSMTMasterCt { concentratorSMTEntry 7 } on the given SMT. The value for each PORT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
OBJECT-TYPE    
  INTEGER 1..65535  

concentratorPORTType 1.3.6.1.4.1.22.70.1.1.1.3
This value specifies the type of selected port
OBJECT-TYPE    
  INTEGER unknown(1), fiber(2), utp(3), stp(4), ibm(5), plastic(6), baseT(7), mono(8)  

concentratorPORTStatus 1.3.6.1.4.1.22.70.1.1.1.4
This value specifies the status of the selected port
OBJECT-TYPE    
  INTEGER ok(1), failed(2), undefind(3)  

concentratorPROCESSORType 1.3.6.1.4.1.22.70.2.1
This value specifies the type of processor
OBJECT-TYPE    
  INTEGER unkown(1), p88(2), p86(3), p186(4), p286(5), p386(6), p486(7)  

concentratorPROCESSORFrequency 1.3.6.1.4.1.22.70.2.2
This value specifies the frequency of the microprocessor (in MHz)
OBJECT-TYPE    
  INTEGER 1..65535  

concentratorSystemMEMORYAvailable 1.3.6.1.4.1.22.70.3.1
This value specifies the amount of memory in kB
OBJECT-TYPE    
  INTEGER 1..65535  

concentratorSystemMEMORYFree 1.3.6.1.4.1.22.70.3.2
This value specifies the available amount of free memory in kB
OBJECT-TYPE    
  INTEGER 1..65535  

concentratorBufferMEMORYAvailable 1.3.6.1.4.1.22.70.3.3
This value specifies the amount of memory in kB
OBJECT-TYPE    
  INTEGER 1..65535  

concentratorMEMORYFlashEPROM 1.3.6.1.4.1.22.70.3.4
This value specifies whether the flash EPROM is present or not
OBJECT-TYPE    
  INTEGER notpresent(1), present(2)  

concentratorSERIALPORTBaudRate 1.3.6.1.4.1.22.70.4.1
This value specifies the actual baud rate
OBJECT-TYPE    
  INTEGER 1..65535  

concentratorSERIALPORTParity 1.3.6.1.4.1.22.70.4.2
This value specifies the type of parity
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

concentratorSERIALPORTStopBits 1.3.6.1.4.1.22.70.4.3
This value specifies the number of stop bits
OBJECT-TYPE    
  INTEGER 1..255  

concentratorVERSIONSBoardSerialNumber 1.3.6.1.4.1.22.70.5.1
This value specifies the serial number of the board
OBJECT-TYPE    
  STRING Size(8)  

concentratorVERSIONSNMP 1.3.6.1.4.1.22.70.5.2
This value specifies the actual SNMP version
OBJECT-TYPE    
  STRING Size(8)  

concentratorVERSIONBIOS 1.3.6.1.4.1.22.70.5.3
This value specifies the actual BIOS version
OBJECT-TYPE    
  STRING Size(8)  

concentratorVERSIONSMT 1.3.6.1.4.1.22.70.5.4
This value specifies the actual SMT version
OBJECT-TYPE    
  STRING Size(8)  

concentratorVERSIONMAC 1.3.6.1.4.1.22.70.5.5
This value specifies the actual MAC version
OBJECT-TYPE    
  STRING Size(1)  

concentratorVERSIONHRDWR 1.3.6.1.4.1.22.70.5.6
This value specifies the actual version of the hardware
OBJECT-TYPE    
  STRING Size(6)  

concentratorVERSIONSlotsNumber 1.3.6.1.4.1.22.70.5.7
The number of slots in the concentrator.
OBJECT-TYPE    
  INTEGER 1..65535  

concentratorVERSIONSlotsTable 1.3.6.1.4.1.22.70.5.8
A list of slot entries. The number of entries is given by the value of the concentratorVERSIONSlotsNumber.
OBJECT-TYPE    
  SEQUENCE OF  
    ConcentratorVERSIONSlotEntry

concentratorVERSIONSlotEntry 1.3.6.1.4.1.22.70.5.8.1
An entry containing information common to a given SLOT number.
OBJECT-TYPE    
  ConcentratorVERSIONSlotEntry  

concentratorVERSIONSlotIndex 1.3.6.1.4.1.22.70.5.8.1.1
The value of the index associated with this particulary slot.
OBJECT-TYPE    
  INTEGER 1..65535  

concentratorVERSIONSlotSerialNumber 1.3.6.1.4.1.22.70.5.8.1.2
The serial number of this slot.
OBJECT-TYPE    
  STRING Size(6)  

concentratorVERSIONSlotId 1.3.6.1.4.1.22.70.5.8.1.3
The identification number of this slot.
OBJECT-TYPE    
  INTEGER 1..255  

concentratorVERSIONSlotHrdwrStatus 1.3.6.1.4.1.22.70.5.8.1.4
The value specifies the hardware state of the slot.
OBJECT-TYPE    
  INTEGER 1..255  

concentratorVERSIONSlotRevision 1.3.6.1.4.1.22.70.5.8.1.5
Revision.
OBJECT-TYPE    
  INTEGER 1..255  

concentratorPOWERFirstSupplyState 1.3.6.1.4.1.22.70.6.1
This value specifies the state of the first power supply
OBJECT-TYPE    
  INTEGER ok(1), failure(2), notpresent(3), reserved(4)  

concentratorPOWERSecondSupplyState 1.3.6.1.4.1.22.70.6.2
This value specifies the state of the second power supply
OBJECT-TYPE    
  INTEGER ok(1), failure(2), notpresent(3), reserved(4)  

concentratorPOWERFirstFANState 1.3.6.1.4.1.22.70.6.3
This value specifies the state of the first fan
OBJECT-TYPE    
  INTEGER ok(1), failure(2)  

concentratorPOWERSecondFANState 1.3.6.1.4.1.22.70.6.4
This value specifies the state of the second power supply
OBJECT-TYPE    
  INTEGER ok(1), failure(2)  

concentratorPOWERTemperature 1.3.6.1.4.1.22.70.6.5
This value specifies the concentrator's temperature (in degrees Celsius)
OBJECT-TYPE    
  INTEGER  

concentratorPOWERBatteryStatus 1.3.6.1.4.1.22.70.6.6
This value specifies the state of the battery
OBJECT-TYPE    
  INTEGER ok(1), failure(2), notpresent(3)  

concentratorMgrAddress 1.3.6.1.4.1.22.70.7.1
By means of this variable an SNMP manager can put or remove its own address into or out of the internal array of the manager's addresses to where the agent sends traps.An SNMP manager can set itself by SET SNMP operation with its own IP address. An SNMP manager can remove itself by SET SNMP operation with the 0.0.0.0 IP address. Operation GET or GET-NEXT returns the manager's address if the manager is in the internall array or 0.0.0.0 IP address wheneverthe manager is not in the internal array. Agent returns the following error codes : If a manager tries to set an address IP address different from that of its own address or a manager tries to set 0.0.0.0 IP address when a manager is not present in the internal buffer, the agent returns value BAD VALUE. If a manager tries to set address its own IP address again (when the manager is already in the internal array), the agent returns the value GENERALL ERROR. If this array is already full ,then GENERALL ERROR value is returned.
OBJECT-TYPE    
  IpAddress  

concentratorTRAFFICSMTTransmits 1.3.6.1.4.1.22.70.9.1
This value specifies transmitted SMT frames
OBJECT-TYPE    
  Counter  

concentratorTRAFFICSMTReceivs 1.3.6.1.4.1.22.70.9.2
This value specifies the recieved SMT frames
OBJECT-TYPE    
  Counter  

concentratorTRAFFICRS232Activity 1.3.6.1.4.1.22.70.9.3
This value specifies whether the RS 232 is currently active
OBJECT-TYPE    
  INTEGER active(1), nonactive(2)