EthernetSubagentPvt-MIB

File: EthernetSubagentPvt-MIB.mib (9218 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB

Imported symbols

private Counter OBJECT-TYPE
TRAP-TYPE DisplayString

Defined Values

enterprises 1.3.6.1.4.1
OBJECT IDENTIFIER    

tandem 1.3.6.1.4.1.169
OBJECT IDENTIFIER    

nonstopsystems 1.3.6.1.4.1.169.3
OBJECT IDENTIFIER    

zesa 1.3.6.1.4.1.169.3.217
OBJECT IDENTIFIER    

zesaAgentName 1.3.6.1.4.1.169.3.217.1
The name of the SNMP Agent process.
OBJECT-TYPE    
  DisplayString Size(0..32)  

zesaAgentState 1.3.6.1.4.1.169.3.217.2
Current status of the agent interface. The state of this variable will always be connected(1) when returned in a management request
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2)  

zesaProcessName 1.3.6.1.4.1.169.3.217.3
The fully qualified NSK process name of this subagent.
OBJECT-TYPE    
  DisplayString Size(0..49)  

zesaProcessVersion 1.3.6.1.4.1.169.3.217.4
The version of this subagent process object file.
OBJECT-TYPE    
  DisplayString Size(0..32)  

zesaProgramFile 1.3.6.1.4.1.169.3.217.5
The Ethernet subagent program file name.
OBJECT-TYPE    
  DisplayString Size(0..32)  

zesaProcessPriority 1.3.6.1.4.1.169.3.217.6
The current NSK process priority of this subagent process.
OBJECT-TYPE    
  INTEGER 0..199  

zesaProcessGroupID 1.3.6.1.4.1.169.3.217.7
the NSK process group ID part of the PAID for this subagent process.
OBJECT-TYPE    
  INTEGER 0..255  

zesaProcessUserID 1.3.6.1.4.1.169.3.217.8
the NSK process user ID part of the PAID for this subagent process.
OBJECT-TYPE    
  INTEGER 0..255  

zesaPrimaryCPU 1.3.6.1.4.1.169.3.217.9
The CPU number of the primary process of this subagent
OBJECT-TYPE    
  INTEGER 0..255  

zesaPrimaryPIN 1.3.6.1.4.1.169.3.217.10
The process number of the primary process of this subagent
OBJECT-TYPE    
  INTEGER 0..255  

zesaBackupCPU 1.3.6.1.4.1.169.3.217.11
The CPU, the backup process will start in or is running in. A value of -1 indicates the backup is not configured. zesaBackupState must be set to disabled(3) prior to setting this object
OBJECT-TYPE    
  INTEGER -1..255  

zesaBackupPIN 1.3.6.1.4.1.169.3.217.12
The process number of the backup process of this subagent. Its value is -1 when the backup is not running
OBJECT-TYPE    
  INTEGER -1..255  

zesaBackupState 1.3.6.1.4.1.169.3.217.13
The state of the backup process of this subagent
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), disabled(3), enabled(4)  

zesaSwitchToBackupNow 1.3.6.1.4.1.169.3.217.14
This object normally reads 0 (autoProcessPairControl) . Setting this object to 1 (forceBackupTakeover) causes the subagent to switch to its backup process immediately after replying OK. Setting this object is only permitted if the zesaBackupState is connected(1)
OBJECT-TYPE    
  INTEGER autoProcessPairControl(0), forceBackupTakeover(1)  

zesaEmsCollectorName 1.3.6.1.4.1.169.3.217.15
The process of the EMS Collector the subagent should send its EMS events to. zesaEmsCollectorState must be set to disabled(3) prior to setting this object
OBJECT-TYPE    
  DisplayString Size(0..15)  

zesaEmsCollectorState 1.3.6.1.4.1.169.3.217.16
The state of the connection to the EMS Collector. The settable values for this object are disabled(3) and enabled(4). The connected(1) and disconnected(2) states are set by the subagent to reflect the running state of the EMS collector interface.
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), disabled(3), enabled(4)  

zesaKeepAliveTimer 1.3.6.1.4.1.169.3.217.17
The number of seconds between attempts the subagent makes to connect to an SNMP Agent, TCP/IP process, SCP process, Collector process and restart the backup process.
OBJECT-TYPE    
  INTEGER 0..32000  

zesaRefreshNow 1.3.6.1.4.1.169.3.217.18
This object normally reads 0 (autoDynamicRefresh). Setting this object to 1 (forceDynamicRefresh) causes the subagent to update the MIB tables and generate traps (if needed).
OBJECT-TYPE    
  INTEGER autoDynamicRefresh(0), forceDynamicRefresh(1)  

zesaRefreshTimer 1.3.6.1.4.1.169.3.217.19
The cache update interval for the MIB objects. Value 0 disables cache timing such that updates occur to objects only when the zesaRefreshNow object is set
OBJECT-TYPE    
  INTEGER 0..32000  

zesaTcpIpProcess 1.3.6.1.4.1.169.3.217.20
The TCP/IP process whose Ethernet interfaces are monitored by the subagent. zesaTcpIpState must be set to disabled(3) prior to setting this object
OBJECT-TYPE    
  DisplayString Size(0..15)  

zesaTcpIpState 1.3.6.1.4.1.169.3.217.21
The state of the connection to the monitored TCP/IP process. The settable values for this object are disabled(3 ) and enabled(4). The connected(1) and disconnected(2) states are set by the subagent to reflect the running state of the TCP/IP resource interface.
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), disabled(3), enabled(4)  

zesaSCPProcess 1.3.6.1.4.1.169.3.217.22
The SCP process used for SPI requests. Value is set by the -s startup parameter. Default is .
OBJECT-TYPE    
  DisplayString Size(0..15)  

zesaTrap 1.3.6.1.4.1.169.3.217.23
String contains the information about the name and status of the line.
OBJECT-TYPE    
  DisplayString Size(0..15)  

zesalinkUp 2
A LinkUp trap signiifies that the status of the line has changed from STOPPED to STARTED state.
TRAP-TYPE    

zesalinkDown 3
A LinkDown trap signiifies that the status of the line has changed from STARTED to STOPPED state.
TRAP-TYPE