EXTREME-NETSIGHT-ALARM-MIB
File:
EXTREME-NETSIGHT-ALARM-MIB.mib (37360 bytes)
Imported modules
Imported symbols
Defined Values
extremeNetsightAlarmMIB |
1.3.6.1.4.1.5624.1.2.105 |
This MIB module defines a portion of the SNMP MIB under
the Enterasys Networks enterprise OID pertaining to
definitions and notifications for the Extreme Netsight
network management software.
This MIB defines a set of notifications that the Netsight
Alarm Manager can send to another SNMP trap receiver. |
MODULE-IDENTITY |
|
|
|
extremeNetsightAlarmMessage |
1.3.6.1.4.1.5624.1.2.105.1.1.1 |
The message describing the specific alarm triggered. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..256) |
|
extremeNetsightAlarmSeverity |
1.3.6.1.4.1.5624.1.2.105.1.1.2 |
The severity of an alarm. Lower values signify more serious
conditions, whereas higher values are less critical. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
INTEGER |
emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), info(6), debug(7) |
|
extremeNetsightAlarmSourceDeviceAddress |
1.3.6.1.4.1.5624.1.2.105.1.1.5 |
The address of the device that triggered this alarm. This
may be the address of the Netsight server itself or a remote
device managed by Netsight. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
InetAddress |
|
|
extremeNetsightAlarmSubcomponent |
1.3.6.1.4.1.5624.1.2.105.1.1.6 |
Additional event specific data for this alarm (e.g. interface
number). Note that in most cases there is no such data,
and this object will be an empty string. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..256) |
|
extremeNetsightAlarmNotification |
1.3.6.1.4.1.5624.1.2.105.1.0.1 |
This notification indicates that an alarm was triggered and
contains information related to that alarm. Note that this
notification is generic and MAY not be used when a more
specific notification is defined for a given alarm.
NOTE: The list of OBJECTS defined for this alarm will
act as a template for all other notifications defined in this
group and they should include the same list. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
extremeNetsightAlarmFanOK |
1.3.6.1.4.1.5624.1.2.105.1.0.6 |
Fan OK |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
extremeNetsightAlarmSettings |
1.3.6.1.4.1.5624.1.2.105.2.1.1 |
A collection of objects for formatting notifications
in the Extreme Netsight Alarm MIB. |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
extremeNetsightAlarmGenericNotificationGroup |
1.3.6.1.4.1.5624.1.2.105.2.1.2 |
A collection of objects required for reporting
notifications with the Extreme Netsight Alarm MIB. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-GROUP |
|
|
|
extremeNetsightAlarmSpecificNotificationGroup |
1.3.6.1.4.1.5624.1.2.105.2.1.3 |
A collection of objects required for reporting
notifications with the Extreme Netsight Alarm MIB. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-GROUP |
|
|
|
extremeNetsightAlarmComplianceGroup |
1.3.6.1.4.1.5624.1.2.105.2.2.1 |
The compliance statement for devices that support
the Extreme Netsight Alarm MIB. |
Status: current |
Access: accessible-for-notify |
MODULE-COMPLIANCE |
|
|
|