EVNTAGENT-MIB

File: EVNTAGENT-MIB.mib (14854 bytes)

Imported modules

SNMPv2-SMI RFC-1215

Imported symbols

OBJECT-TYPE enterprises TRAP-TYPE

Defined Values

microsoft 1.3.6.1.4.1.311
OBJECT IDENTIFIER    

software 1.3.6.1.4.1.311.1
OBJECT IDENTIFIER    

eventlog 1.3.6.1.4.1.311.1.13
OBJECT IDENTIFIER    

evntagent 1.3.6.1.4.1.311.1.13.1
OBJECT IDENTIFIER    

eventData 1.3.6.1.4.1.311.1.13.1.9999
OBJECT IDENTIFIER    

security 1.3.6.1.4.1.311.1.13.1.8.83.101.99.117.114.105.116.121
OBJECT IDENTIFIER    

svcCtlMgr 1.3.6.1.4.1.311.1.13.1.23.83.101.114.118.105.99.101.32.67.111.110.116.114.111.108.32.77.97.110.97.103.101.114
OBJECT IDENTIFIER    

w32Time 1.3.6.1.4.1.311.1.13.1.7.87.51.50.84.105.109.101
OBJECT IDENTIFIER    

eventText 1.3.6.1.4.1.311.1.13.1.9999.1
The event message text. The message data is populated with the variable data below.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventUserId 1.3.6.1.4.1.311.1.13.1.9999.2
The user ID of the process that generated the event.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventSystem 1.3.6.1.4.1.311.1.13.1.9999.3
The computername of the host that generated the event.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventType 1.3.6.1.4.1.311.1.13.1.9999.4
The numeric code value of the event type.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventCategory 1.3.6.1.4.1.311.1.13.1.9999.5
The numeric code value of the event category.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar1 1.3.6.1.4.1.311.1.13.1.9999.6
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar2 1.3.6.1.4.1.311.1.13.1.9999.7
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar3 1.3.6.1.4.1.311.1.13.1.9999.8
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar4 1.3.6.1.4.1.311.1.13.1.9999.9
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar5 1.3.6.1.4.1.311.1.13.1.9999.10
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar6 1.3.6.1.4.1.311.1.13.1.9999.11
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar7 1.3.6.1.4.1.311.1.13.1.9999.12
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar8 1.3.6.1.4.1.311.1.13.1.9999.13
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar9 1.3.6.1.4.1.311.1.13.1.9999.14
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar10 1.3.6.1.4.1.311.1.13.1.9999.15
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar11 1.3.6.1.4.1.311.1.13.1.9999.16
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar12 1.3.6.1.4.1.311.1.13.1.9999.17
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar13 1.3.6.1.4.1.311.1.13.1.9999.18
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar14 1.3.6.1.4.1.311.1.13.1.9999.19
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventVar15 1.3.6.1.4.1.311.1.13.1.9999.20
Event-specific variable data
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

w32SystemStartup 512
Windows is starting up.
TRAP-TYPE    

w32SystemShutdown 513
Windows is shutting down.
TRAP-TYPE    

w32LogonSuccess 528
Logon succeeded.
TRAP-TYPE    

w32LogonFailure 529
Logon failed.
TRAP-TYPE    

w32LogoffSuccess 538
Logoff succeeded.
TRAP-TYPE    

w32NetLogonSuccess 540
Network logon succeeded.
TRAP-TYPE    

w32ServiceDiedHung 0
The service hung on starting.
TRAP-TYPE    

w32ServiceDiedSysErr 0
The service terminated with the following error.
TRAP-TYPE    

w32ServiceDiedSvcErr 0
The service terminated with a service-specific error.
TRAP-TYPE    

w32ServiceStartHung 0
The service terminated with the following error.
TRAP-TYPE    

w32ServiceControlSuccess 1073748859
The service was successfully sent a state-change signal.
TRAP-TYPE    

w32ServiceStateChange 1073748860
The service has changed its running state.
TRAP-TYPE    

w32NtpSynchSuccess 1113194531
NTP time synchronization has succeeded.
TRAP-TYPE    

w32NtpInaccessible 0
None of the NTP time providers are accessible.
TRAP-TYPE