ESM-snmp

File: ESM-snmp.mib (108555 bytes)

Imported modules

RFC-1215 SNMPv2-TC RFC1155-SMI
RFC1213-MIB SNMPv2-PARTY-MIB RFC-1212

Imported symbols

TRAP-TYPE DisplayString mgmt
NetworkAddress IpAddress Counter
Gauge TimeTicks internet
PhysAddress Party Context
OBJECT-TYPE

Defined Types

Party  
OBJECT IDENTIFIER    

Context  
OBJECT IDENTIFIER    

RTrapAddrEntry  
SEQUENCE    
  rTrapAddrAddr IpAddress
  rTrapAddrComm DisplayString
  rTrapAddrVer INTEGER
  rTrapAddrType OCTET STRING
  rTrapAddrState INTEGER
  rTrapAddrFlag INTEGER
  rTrapAddrAge INTEGER

PTrapAddrEntry  
SEQUENCE    
  pTrapAddrAddr IpAddress
  pTrapAddrComm DisplayString
  pTrapAddrVer INTEGER
  pTrapAddrType OCTET STRING
  pTrapAddrState INTEGER

FmSlotEntry  
SEQUENCE    
  fmSlotIndex INTEGER
  fmSlotID INTEGER
  fmSlotDescr DisplayString
  fmSlotInfo DisplayString
  fmSlotStatus OCTET STRING
  fmSlotPrevStatus OCTET STRING
  fmSlotRLBSet INTEGER
  fmSlotRLBClear INTEGER
  fmSlotExpCode INTEGER
  fmSlotTrapMask INTEGER
  pfmSlotTrapMask INTEGER
  fmSlotIpAddr IpAddress
  fmSlotMngAccess INTEGER
  pfmSlotMngAccess INTEGER
  fmSlotEntityIndex INTEGER
  fmSlotCommunity DisplayString
  fmSlotEntityManager INTEGER

FmDiagFaultEntry  
SEQUENCE    
  fmDiagFaultIndex INTEGER
  fmDiagFaultReport DisplayString

GigaPhyResourceEntry  
SEQUENCE    
  gigaPhyResLocationType INTEGER
  gigaPhyResLocation INTEGER
  gigaPhyResIndex INTEGER
  gigaPhyResType OBJECT IDENTIFIER
  gigaPhyResCapability INTEGER
  gigaPhyResSegRing INTEGER

GigaEbmEntry  
SEQUENCE    
  gigaEbmIndex INTEGER
  gigaEbmDescr DisplayString
  gigaEbmOperStatus INTEGER

AutonomousType  
OBJECT IDENTIFIER    

ChasPhyLocationEntry  
SEQUENCE    
  chasPhyLocationTypeIndex INTEGER
  chasPhyLocationCount INTEGER
  chasPhyLocationType OBJECT IDENTIFIER
  chasPhyLocationDescr DisplayString

ChasPhyModuleEntry  
SEQUENCE    
  chasPhyModuleLocationType INTEGER
  chasPhyModuleLocation INTEGER
  chasPhyModuleType OBJECT IDENTIFIER
  chasPhyModuleSwVersion DisplayString
  chasPhyModuleHwVersion DisplayString
  chasPhyModuleSerialNumber DisplayString
  chasPhyModuleDescription DisplayString
  chasPhyModuleLastChangeTime TimeTicks
  chasPhyModuleAdminStatus INTEGER
  chasPhyModuleOperStatus INTEGER

ChasEntityEntry  
SEQUENCE    
  chasEntityIndex INTEGER
  chasEntityObjectID OBJECT IDENTIFIER
  chasEntityDescr DisplayString
  chasEntityAdminStatus INTEGER
  chasEntityOperStatus INTEGER
  chasEntityTimeStamp TimeTicks
  chasEntityParty Party
  chasEntityContext Context
  chasEntityCommunity DisplayString
  chasEntityIpAddress IpAddress

ChasPhyResourceEntry  
SEQUENCE    
  chasPhyResLocationType INTEGER
  chasPhyResLocation INTEGER
  chasPhyResIndex INTEGER
  chasPhyResType OBJECT IDENTIFIER
  chasPhyResAssignment INTEGER
  chasPhyResEntitySubIndex INTEGER

ChasLogResourceEntry  
SEQUENCE    
  chasLogResEntity INTEGER
  chasLogResEntitySubIndex INTEGER
  chasLogResLocationType INTEGER
  chasLogResLocation INTEGER
  chasLogResIndex INTEGER

ChasPowerSupplyEntry  
SEQUENCE    
  chasPowerSupplyIndex INTEGER
  chasPowerSupplyDescr DisplayString
  chasPowerSupplyAdminStatus INTEGER
  chasPowerSupplyOperStatus INTEGER
  chasPowerSupplyHealthText DisplayString
  chasPowerSupplyWarnings Counter
  chasPowerSupplyFailures Counter
  chasPowerSupplyLocationType INTEGER
  chasPowerSupplyLocationIndex INTEGER

ChasPowerSupplyOutputEntry  
SEQUENCE    
  chasPowerSupplyIdIndex INTEGER
  chasPowerSupplyOutputIndex INTEGER
  chasPowerSupplyOutputStatus INTEGER
  chasPowerSupplyOutputNominalVoltage INTEGER
  chasPowerSupplyOutputOfferedVoltage INTEGER
  chasPowerSupplyOutputOfferedWattage INTEGER
  chasPowerSupplyOutputWarnings Counter
  chasPowerSupplyOutputFailures Counter

ChasEnvironEntry  
SEQUENCE    
  chasEnvironLocationType INTEGER
  chasEnvironLocationIndex INTEGER
  chasEnvironIndex INTEGER
  chasEnvironSensor AutonomousType
  chasEnvironStatus INTEGER
  chasEnvironWarnings Counter
  chasEnvironFailures Counter

Defined Values

private 1.3.6.1.4
OBJECT IDENTIFIER    

enterprises 1.3.6.1.4.1
OBJECT IDENTIFIER    

fibronics 1.3.6.1.4.1.22
OBJECT IDENTIFIER    

trap 1.3.6.1.4.1.22.3
OBJECT IDENTIFIER    

traprun 1.3.6.1.4.1.22.3.1
OBJECT IDENTIFIER    

traperm 1.3.6.1.4.1.22.3.2
OBJECT IDENTIFIER    

trapvar 1.3.6.1.4.1.22.3.3
OBJECT IDENTIFIER    

fm800 1.3.6.1.4.1.22.51
OBJECT IDENTIFIER    

fmsystem 1.3.6.1.4.1.22.51.1
OBJECT IDENTIFIER    

fmslot 1.3.6.1.4.1.22.51.2
OBJECT IDENTIFIER    

fmlu 1.3.6.1.4.1.22.51.3
OBJECT IDENTIFIER    

fmdiag 1.3.6.1.4.1.22.51.5
OBJECT IDENTIFIER    

fmsystemrun 1.3.6.1.4.1.22.51.1.1
OBJECT IDENTIFIER    

fmsystemperm 1.3.6.1.4.1.22.51.1.2
OBJECT IDENTIFIER    

fmrptr 1.3.6.1.4.1.22.51.11
OBJECT IDENTIFIER    

lc308-129 1.3.6.1.4.1.22.51.11.1
OBJECT IDENTIFIER    

lc303-129 1.3.6.1.4.1.22.51.11.3
OBJECT IDENTIFIER    

lc312-129 1.3.6.1.4.1.22.51.11.5
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.22.100
OBJECT IDENTIFIER    

eth-rptrs 1.3.6.1.4.1.22.100.1
OBJECT IDENTIFIER    

tr-concentrators 1.3.6.1.4.1.22.100.2
OBJECT IDENTIFIER    

fddi-concentrators 1.3.6.1.4.1.22.100.3
OBJECT IDENTIFIER    

brouters 1.3.6.1.4.1.22.100.4
OBJECT IDENTIFIER    

terminal-servers 1.3.6.1.4.1.22.100.5
OBJECT IDENTIFIER    

chassis 1.3.6.1.4.1.22.100.6
OBJECT IDENTIFIER    

mux 1.3.6.1.4.1.22.100.7
OBJECT IDENTIFIER    

atm-switch 1.3.6.1.4.1.22.100.8
OBJECT IDENTIFIER    

eth-switch 1.3.6.1.4.1.22.100.9
OBJECT IDENTIFIER    

tr-hubs 1.3.6.1.4.1.22.100.10
OBJECT IDENTIFIER    

bridges 1.3.6.1.4.1.22.100.11
OBJECT IDENTIFIER    

xmh-rptrs 1.3.6.1.4.1.22.100.1.1
OBJECT IDENTIFIER    

lc342-rptr 1.3.6.1.4.1.22.100.1.1.1
OBJECT IDENTIFIER    

lc348-rptr 1.3.6.1.4.1.22.100.1.1.2
OBJECT IDENTIFIER    

nm349-sm 1.3.6.1.4.1.22.100.1.1.3
OBJECT IDENTIFIER    

lc343-rptr 1.3.6.1.4.1.22.100.1.1.4
OBJECT IDENTIFIER    

lc344-rptr 1.3.6.1.4.1.22.100.1.1.5
OBJECT IDENTIFIER    

tr-rptrs 1.3.6.1.4.1.22.100.10.2
OBJECT IDENTIFIER    

lc366-rptr 1.3.6.1.4.1.22.100.10.2.1
OBJECT IDENTIFIER    

lc362-rptr 1.3.6.1.4.1.22.100.10.2.2
OBJECT IDENTIFIER    

nm369-sm 1.3.6.1.4.1.22.100.10.2.3
OBJECT IDENTIFIER    

em364-trnk 1.3.6.1.4.1.22.100.10.2.4
OBJECT IDENTIFIER    

em365-trnk 1.3.6.1.4.1.22.100.10.2.5
OBJECT IDENTIFIER    

lc366p-rptr 1.3.6.1.4.1.22.100.10.2.1.1
OBJECT IDENTIFIER    

lc362p-rptr 1.3.6.1.4.1.22.100.10.2.2.2
OBJECT IDENTIFIER    

em364p-trnk 1.3.6.1.4.1.22.100.10.2.4.1
OBJECT IDENTIFIER    

xm512-card 1.3.6.1.4.1.22.100.9.1
OBJECT IDENTIFIER    

xm514-card 1.3.6.1.4.1.22.100.9.2
OBJECT IDENTIFIER    

xm516-card 1.3.6.1.4.1.22.100.9.3
OBJECT IDENTIFIER    

xm504-card 1.3.6.1.4.1.22.100.8.1
OBJECT IDENTIFIER    

eth2fddi 1.3.6.1.4.1.22.100.11.1
OBJECT IDENTIFIER    

fx8616 1.3.6.1.4.1.22.100.11.1.1
OBJECT IDENTIFIER    

gigaHUB 1.3.6.1.4.1.22.100.6.1
OBJECT IDENTIFIER    

gigaLocationTypes 1.3.6.1.4.1.22.100.6.1.1
OBJECT IDENTIFIER    

gigaEsmBay 1.3.6.1.4.1.22.100.6.1.1.1
OBJECT IDENTIFIER    

gigaModuleTypes 1.3.6.1.4.1.22.100.6.1.2
OBJECT IDENTIFIER    

gigaEsm 1.3.6.1.4.1.22.100.6.1.2.1
OBJECT IDENTIFIER    

gigaPowerSupply 1.3.6.1.4.1.22.100.6.1.2.2
OBJECT IDENTIFIER    

midiGigaHUB 1.3.6.1.4.1.22.100.6.1.3
OBJECT IDENTIFIER    

cc010 1.3.6.1.4.1.22.100.7.1
OBJECT IDENTIFIER    

cc012 1.3.6.1.4.1.22.100.7.2
OBJECT IDENTIFIER    

cc020 1.3.6.1.4.1.22.100.7.3
OBJECT IDENTIFIER    

cc031 1.3.6.1.4.1.22.100.7.4
OBJECT IDENTIFIER    

cc032 1.3.6.1.4.1.22.100.7.5
OBJECT IDENTIFIER    

cc041 1.3.6.1.4.1.22.100.7.6
OBJECT IDENTIFIER    

cc042 1.3.6.1.4.1.22.100.7.7
OBJECT IDENTIFIER    

cc044 1.3.6.1.4.1.22.100.7.8
OBJECT IDENTIFIER    

cc832 1.3.6.1.4.1.22.100.7.9
OBJECT IDENTIFIER    

cc201 1.3.6.1.4.1.22.100.7.10
OBJECT IDENTIFIER    

cc202 1.3.6.1.4.1.22.100.7.11
OBJECT IDENTIFIER    

cc214 1.3.6.1.4.1.22.100.7.12
OBJECT IDENTIFIER    

cc321 1.3.6.1.4.1.22.100.7.13
OBJECT IDENTIFIER    

cc301 1.3.6.1.4.1.22.100.7.14
OBJECT IDENTIFIER    

cc233 1.3.6.1.4.1.22.100.7.15
OBJECT IDENTIFIER    

cc260 1.3.6.1.4.1.22.100.7.16
OBJECT IDENTIFIER    

sw11X 1.3.6.1.4.1.22.100.7.17
OBJECT IDENTIFIER    

cc432 1.3.6.1.4.1.22.100.7.18
OBJECT IDENTIFIER    

cc420 1.3.6.1.4.1.22.100.7.19
OBJECT IDENTIFIER    

cc421 1.3.6.1.4.1.22.100.7.20
OBJECT IDENTIFIER    

cc422 1.3.6.1.4.1.22.100.7.21
OBJECT IDENTIFIER    

cc401 1.3.6.1.4.1.22.100.7.22
OBJECT IDENTIFIER    

cc24X 1.3.6.1.4.1.22.100.7.23
OBJECT IDENTIFIER    

cc427 1.3.6.1.4.1.22.100.7.24
OBJECT IDENTIFIER    

cc211 1.3.6.1.4.1.22.100.7.25
OBJECT IDENTIFIER    

cc212 1.3.6.1.4.1.22.100.7.26
OBJECT IDENTIFIER    

cc010-ID 1.3.6.1.4.1.22.100.7.27
OBJECT IDENTIFIER    

cc012-ID 1.3.6.1.4.1.22.100.7.28
OBJECT IDENTIFIER    

cc020-ID 1.3.6.1.4.1.22.100.7.29
OBJECT IDENTIFIER    

cc041-ID 1.3.6.1.4.1.22.100.7.30
OBJECT IDENTIFIER    

cc042-ID 1.3.6.1.4.1.22.100.7.31
OBJECT IDENTIFIER    

cc044-ID 1.3.6.1.4.1.22.100.7.32
OBJECT IDENTIFIER    

cc046A 1.3.6.1.4.1.22.100.7.33
OBJECT IDENTIFIER    

cc046B 1.3.6.1.4.1.22.100.7.34
OBJECT IDENTIFIER    

not-exist 1.3.6.1.4.1.22.100.7.100
OBJECT IDENTIFIER    

cc303 1.3.6.1.4.1.22.100.1.3
OBJECT IDENTIFIER    

cc308 1.3.6.1.4.1.22.100.1.4
OBJECT IDENTIFIER    

lc303 1.3.6.1.4.1.22.100.1.5
OBJECT IDENTIFIER    

lc308 1.3.6.1.4.1.22.100.1.6
OBJECT IDENTIFIER    

lc312 1.3.6.1.4.1.22.100.1.7
OBJECT IDENTIFIER    

lc322 1.3.6.1.4.1.22.100.2.1
OBJECT IDENTIFIER    

mibs 1.3.6.1.4.1.22.101
OBJECT IDENTIFIER    

systems 1.3.6.1.4.1.22.101.1
OBJECT IDENTIFIER    

mibsstack-rptrs 1.3.6.1.4.1.22.101.2
OBJECT IDENTIFIER    

mibstr-hubs 1.3.6.1.4.1.22.101.3
OBJECT IDENTIFIER    

mibsfddi-concentrators 1.3.6.1.4.1.22.101.4
OBJECT IDENTIFIER    

mibsbrouters 1.3.6.1.4.1.22.101.5
OBJECT IDENTIFIER    

chassis-mibs 1.3.6.1.4.1.22.101.6
OBJECT IDENTIFIER    

mibsterminal-servers 1.3.6.1.4.1.22.101.7
OBJECT IDENTIFIER    

mibseth-rptrs 1.3.6.1.4.1.22.101.8
OBJECT IDENTIFIER    

mibsbridges 1.3.6.1.4.1.22.101.9
OBJECT IDENTIFIER    

mibbridges-specific 1.3.6.1.4.1.22.101.9.1
OBJECT IDENTIFIER    

mibbridges-general 1.3.6.1.4.1.22.101.9.2
OBJECT IDENTIFIER    

mibeth2fddi 1.3.6.1.4.1.22.101.9.1.1
OBJECT IDENTIFIER    

mibeth2eth 1.3.6.1.4.1.22.101.9.1.2
OBJECT IDENTIFIER    

mib-fx8616 1.3.6.1.4.1.22.101.9.1.1.1
OBJECT IDENTIFIER    

mib-xm516 1.3.6.1.4.1.22.101.9.1.2.1
OBJECT IDENTIFIER    

gigaHUBMib 1.3.6.1.4.1.22.101.6.1
OBJECT IDENTIFIER    

gigaHUBPrivate 1.3.6.1.4.1.22.101.6.1.1
OBJECT IDENTIFIER    

gigaHUBChassis 1.3.6.1.4.1.22.101.6.1.2
OBJECT IDENTIFIER    

nonProductsOids 1.3.6.1.4.1.22.102
OBJECT IDENTIFIER    

resource-oids 1.3.6.1.4.1.22.102.1
OBJECT IDENTIFIER    

entity-oids 1.3.6.1.4.1.22.102.2
OBJECT IDENTIFIER    

sensor-oids 1.3.6.1.4.1.22.102.3
OBJECT IDENTIFIER    

eth-resources 1.3.6.1.4.1.22.102.1.1
OBJECT IDENTIFIER    

eth-switch-resources 1.3.6.1.4.1.22.102.1.2
OBJECT IDENTIFIER    

atm-switch-resources 1.3.6.1.4.1.22.102.1.3
OBJECT IDENTIFIER    

tr-resources 1.3.6.1.4.1.22.102.1.4
OBJECT IDENTIFIER    

esb-resource 1.3.6.1.4.1.22.102.1.1.1
OBJECT IDENTIFIER    

eb2-resource 1.3.6.1.4.1.22.102.1.1.2
OBJECT IDENTIFIER    

repeater-manager-resource 1.3.6.1.4.1.22.102.1.1.3
OBJECT IDENTIFIER    

eb2-one-resource 1.3.6.1.4.1.22.102.1.2.1
OBJECT IDENTIFIER    

eb2-two-resource 1.3.6.1.4.1.22.102.1.2.2
OBJECT IDENTIFIER    

eb2-three-resource 1.3.6.1.4.1.22.102.1.2.3
OBJECT IDENTIFIER    

eb2-four-resource 1.3.6.1.4.1.22.102.1.2.4
OBJECT IDENTIFIER    

em501-resource 1.3.6.1.4.1.22.102.1.3.1
OBJECT IDENTIFIER    

em502-resource 1.3.6.1.4.1.22.102.1.3.2
OBJECT IDENTIFIER    

tr4-resource 1.3.6.1.4.1.22.102.1.4.1
OBJECT IDENTIFIER    

tr16-resource 1.3.6.1.4.1.22.102.1.4.2
OBJECT IDENTIFIER    

rTrapAddrTable 1.3.6.1.4.1.22.3.1.1
Table of managers to which traps must be sent. Up to 10 entries in table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RTrapAddrEntry

rTrapAddrEntry 1.3.6.1.4.1.22.3.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RTrapAddrEntry  

rTrapAddrAddr 1.3.6.1.4.1.22.3.1.1.1.1
IP address of entity requesting event notification
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

rTrapAddrComm 1.3.6.1.4.1.22.3.1.1.1.2
Community name the receiving entity will expect. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

rTrapAddrVer 1.3.6.1.4.1.22.3.1.1.1.3
Version number supported by destination node
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rTrapAddrType 1.3.6.1.4.1.22.3.1.1.1.4
Type of event that should be reported to this address, bit 0 - authentication trap bit 1 - other SNMP traps bit 2 - Error Traps bit 3 - Diagnostic Traps bit 4 - Debug Traps bit 5 - Enterprise Traps other than fmDiagGenericTrap
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

rTrapAddrState 1.3.6.1.4.1.22.3.1.1.1.5
Determines status of this entry
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

rTrapAddrFlag 1.3.6.1.4.1.22.3.1.1.1.6
If the entry is fixed, it can not be deleted because of aging
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), removable(1)  

rTrapAddrAge 1.3.6.1.4.1.22.3.1.1.1.7
Aging time of the entry (in sec)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rTrapLearning 1.3.6.1.4.1.22.3.1.2
Learn the addresses of the managers automatically.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

rTrapAging 1.3.6.1.4.1.22.3.1.3
Time in sec. until we erase a trap entry
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pTrapAddrTable 1.3.6.1.4.1.22.3.2.1
Table of managers to which traps must be sent. Up to 10 entries in table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PTrapAddrEntry

pTrapAddrEntry 1.3.6.1.4.1.22.3.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PTrapAddrEntry  

pTrapAddrAddr 1.3.6.1.4.1.22.3.2.1.1.1
IP address of entity requesting event notification
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pTrapAddrComm 1.3.6.1.4.1.22.3.2.1.1.2
Community name the receiving entity will expect. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pTrapAddrVer 1.3.6.1.4.1.22.3.2.1.1.3
Version number supported by destination node
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

pTrapAddrType 1.3.6.1.4.1.22.3.2.1.1.4
Type of event that should be reported to this address, bit 0 - authentication trap bit 1 - other SNMP traps bit 2 - Error Traps bit 3 - Diagnostic Traps bit 4 - Debug Traps bit 5 - all Enterprise Traps other than fmDiagGenericTrap
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pTrapAddrState 1.3.6.1.4.1.22.3.2.1.1.5
Determines status of this entry
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

pTrapLearning 1.3.6.1.4.1.22.3.2.2
Learn the addresses of the managers automatically.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

pTrapAging 1.3.6.1.4.1.22.3.2.3
Time in sec. until we erase a trap entry
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSystemReset 1.3.6.1.4.1.22.51.1.1.4
Resetting the CARD. When reading the instance of this object the value has no meaning. cold reset is performed with selftest , while warm start is performed without selftest
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cold-reset(0), warm-reset(1), power-up(2), meaning-less-value(127)  

fmSystemSelfTestLevel 1.3.6.1.4.1.22.51.1.1.5
Type of self test to be executed upon cold-reset
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(0), partial(1), full(2), extended(3)  

fmSystemVersion 1.3.6.1.4.1.22.51.1.1.6
Version of the station. The version includes station type, hardware version and software version. The string can include CR and LF
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fmSystemIpAddr 1.3.6.1.4.1.22.51.1.1.7
IP address of the agent
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemIPNetMask 1.3.6.1.4.1.22.51.1.1.8
IP Network Mask
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemIPDefGway 1.3.6.1.4.1.22.51.1.1.9
Default Gateway Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemFileServer 1.3.6.1.4.1.22.51.1.1.10
IP address to which a TFTP for boot is sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

fmSystemBootFile 1.3.6.1.4.1.22.51.1.1.11
Path and file name that is sent as a TFTP request
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fmSystemBootMode 1.3.6.1.4.1.22.51.1.1.12
Method for booting
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER internal-memory(1), bootp(2)  

fmSystemDownLoad 1.3.6.1.4.1.22.51.1.1.13
Downloading the ESM. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER download(1), meaning-less-value(127)  

fmSystemSlipIpAddr 1.3.6.1.4.1.22.51.1.1.14
SLIP IP address. This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemSlipIPNetMask 1.3.6.1.4.1.22.51.1.1.15
SLIP IP Network Mask This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSystemSlipBaudRate 1.3.6.1.4.1.22.51.1.1.16
SLIP Baud rate This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER baud1200(0), baud2400(1), baud4800(2), baud9600(3), baud19200(4), baud38400(5)  

fmSystemSlipParity 1.3.6.1.4.1.22.51.1.1.17
SLIP Parity This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(0), odd(1), even(2)  

fmSystemSlipStopBits 1.3.6.1.4.1.22.51.1.1.18
SLIP Stop Bits This is object is available only when slip interface exist
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(0), two(1)  

pfmSystemIpAddr 1.3.6.1.4.1.22.51.1.2.7
IP address of the agent
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemIPNetMask 1.3.6.1.4.1.22.51.1.2.8
IP Network Mask
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemIPDefGway 1.3.6.1.4.1.22.51.1.2.9
Default Gateway Address
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemFileServer 1.3.6.1.4.1.22.51.1.2.10
IP address to which a TFTP for boot is sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemBootFile 1.3.6.1.4.1.22.51.1.2.11
Path and file name that is sent as a TFTP request
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pfmSystemBootMode 1.3.6.1.4.1.22.51.1.2.12
Method for booting
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal-memory(1), bootp(2)  

pfmSystemReadCommunity 1.3.6.1.4.1.22.51.1.2.13
Community string for reading When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pfmSystemWriteCommunity 1.3.6.1.4.1.22.51.1.2.14
Community string for writing When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pfmSystemSlipIpAddr 1.3.6.1.4.1.22.51.1.2.15
SLIP IP address This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemSlipIPNetMask 1.3.6.1.4.1.22.51.1.2.16
SLIP IP Network Mask This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

pfmSystemSlipBaudRate 1.3.6.1.4.1.22.51.1.2.17
SLIP Baud rate This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud1200(0), baud2400(1), baud4800(2), baud9600(3), baud19200(4), baud38400(5)  

pfmSystemSlipParity 1.3.6.1.4.1.22.51.1.2.18
SLIP Parity This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(0), odd(1), even(2)  

pfmSystemSlipStopBits 1.3.6.1.4.1.22.51.1.2.19
SLIP Stop Bits This is object is available only when slip interface exist
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(0), two(1)  

fmSlotMasterClear 1.3.6.1.4.1.22.51.2.1
Upon writing, performs a master clear command on all the slots. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSlotTable 1.3.6.1.4.1.22.51.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmSlotEntry

fmSlotEntry 1.3.6.1.4.1.22.51.2.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FmSlotEntry  

fmSlotIndex 1.3.6.1.4.1.22.51.2.2.1.1
Slot Number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fmSlotID 1.3.6.1.4.1.22.51.2.2.1.2
ID of the card in the slot. Special , not-exist, ID identifies a GigaHUB slot that doesn't exist: slot 5, if a HALF MultiHUB installed, or slot 9, if a FULL MultiHUB installed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unconfig(0), empty(1), cc10(2), cc12(3), cc20(4), cc31(5), cc32(6), cc41(7), cc42(8), cc44(9), cc46A(10), not-exist(11), cc832(65537), lc322(65540), cc201(65544), cc202(65545), cc214(65548), cc321(65552), cc046B(65553), cc301(65560), cc303(65562), cc308(65563), cc233(65568), cc260(65576), cc427(65580), sw11X(65584), cc432(65588), cc420(65589), cc421(65591), cc422(65590), cc401(65592), cc24X(65594), cc211(65550), cc212(65551), lc303(65566), lc308(65567), lc312(65578), cc010-ID(65541), cc012-ID(65542), cc020-ID(65543), cc041-ID(65557), cc042-ID(65558), cc044-ID(65559), general-smartcard(131072), lc308-129(131073), lc303-129(131075), lc312-129(131077), lc342(285278465), lc348(285278466), lc343(285278467), lc344(285278468), lc342-nm349(285409537), lc348-nm349(285409538), lc343-nm349(285409539), lc344-nm349(285409540), lc366(302055681), lc362(302055684), lc362-em364(302055682), lc362-em365(302055683), lc362-em364p(302055685), lc366p(302055686), lc362p(302055689), lc362p-em364(302055687), lc362p-em365(302055688), lc362p-em364p(302055690), xm516(335740929)  

fmSlotDescr 1.3.6.1.4.1.22.51.2.2.1.3
Ascii string. Description of the card
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fmSlotInfo 1.3.6.1.4.1.22.51.2.2.1.4
User general info for the slot. Can be the use of that slot, its location etc...
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

fmSlotStatus 1.3.6.1.4.1.22.51.2.2.1.5
Status bits of the card in the slot, organized by card channel. Each channel's status occupies 2 bytes. For more information about the meaning of the status, read the specific user manual of each card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmSlotPrevStatus 1.3.6.1.4.1.22.51.2.2.1.6
Previous status bits of the card in the slot, organized by card channel. Each channel's status occupies 2 bytes. For more information about the meaning of the status, read the specific user manual of each card. This object id is used mainly for traps (see Card Trap).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmSlotRLBSet 1.3.6.1.4.1.22.51.2.2.1.7
Argument: 1 - 4. Perform a RLB set operation on the channel passed as argument. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSlotRLBClear 1.3.6.1.4.1.22.51.2.2.1.8
Argument: 1 - 4. Perform a RLB clear operation on the channel passed as argument. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSlotExpCode 1.3.6.1.4.1.22.51.2.2.1.9
Perform an expanded command on the slot. For expanded codes, see specific card user manual. When reading the instance of this object the value has no meaning. Extended command codes for NDS cards ------------------------------------ 1. CC892.303 (Ethernet) Code (Dec/Hex) Command ----------------------------------- 02/02 Detach Port 13 03/03 Attach Port 13 04/04 Detach Port 01 05/05 Attach Port 01 06/06 Detach Port 02 07/07 Attach Port 02 08/08 Detach Port 03 09/09 Attach Port 03 10/0A Detach Port 04 11/0B Attach Port 04 12/0C Detach Port 05 13/0D Attach Port 05 14/0E Detach Port 06 15/0F Attach Port 06 16/10 Detach Port 07 17/11 Attach Port 07 18/12 Detach Port 08 19/13 Attach Port 08 20/14 Detach Port 09 21/15 Attach Port 09 22/16 Detach Port 10 23/17 Attach Port 10 24/18 Detach Port 11 25/19 Attach Port 11 26/1A Detach Port 12 27/1B Attach Port 12 28/1C Detach All Ports 29/1D Attach All Ports 30/1E Reset Card 31/1F Link Select ====================================================== 2. CC892.308 (Ethernet) Code (Dec/Hex) Command ----------------------------------- 02/02 Detach Port 01 03/03 Attach Port 01 04/04 Detach Port 02 05/05 Attach Port 02 06/06 Detach Port 03 07/07 Attach Port 03 08/08 Detach Port 04 09/09 Attach Port 04 10/0A Detach Port 05 11/0B Attach Port 05 12/0C Detach Port 06 13/0D Attach Port 06 14/0E Detach Port 07 15/0F Attach Port 07 16/10 Detach Port 08 17/11 Attach Port 08 ... 28/1C Detach All Ports 29/1D Attach All Ports 30/1E Reset Card 31/1F Link Select ================================================ 3. CC892.322 (Token-ring) Module 323 ---------- Code (Dec/Hex) Command ----------------------------------- 02/02 Detach Port 01 03/03 Attach Port 01 04/04 Detach Port 02 05/05 Attach Port 02 06/06 Detach Port 03 07/07 Attach Port 03 08/08 Detach Port 04 09/09 Attach Port 04 10/0A Detach Port 05 11/0B Attach Port 05 12/0C Detach Port 06 13/0D Attach Port 06 18/12 Detach Port 07 19/13 Attach Port 07 20/14 Detach Port 08 21/15 Attach Port 08 22/16 Detach Port 19 23/17 Attach Port 19 24/18 Detach Port 10 25/19 Attach Port 10 26/1A Detach Port 11 27/1B Attach Port 11 28/1C Detach Port 12 29/1D Attach Port 12 30/1E Reset Card 34/22 Detach Port 13 35/23 Attach Port 13 36/24 Detach Port 14 37/25 Attach Port 14 38/26 Detach Port 15 39/27 Attach Port 15 40/28 Detach Port 16 41/29 Attach Port 16 42/2A Detach Port 17 43/2B Attach Port 17 44/2C Detach Port 18 45/2D Attach Port 18 50/32 Detach Port 19 51/33 Attach Port 19 52/34 Detach Port 20 53/35 Attach Port 20 54/36 Detach Port 21 55/37 Attach Port 21 56/38 Detach Port 22 57/39 Attach Port 22 58/3A Detach Port 23 59/3B Attach Port 23 60/3C Detach Port 24 61/3D Attach Port 24 77/4D Detach All Ports 79/4F Attach All Ports ======================================================== Module 325 ---------- 30/1E Reset Card 80/50 Detach Local Port 1 (channel 1) 81/51 Attach Local Port 1 (channel 1) 82/52 Detach Local Port 2 (channel 1) 83/53 Attach Local Port 2 (channel 1) 88/58 Detach Local Port 1 (channel 3) 89/59 Attach Local Port 1 (channel 3) 90/5A Detach Local Port 2 (channel 3) 91/5B Attach Local Port 2 (channel 3) 77/4D Detach All Ports 79/4F Attach All Ports 4. CC892.427 (Voice) Code (Dec/Hex) Command ----------------------------------- 04/04 Loopback OFF on Port 1 05/05 Loopback ON on Port 1 06/06 Loopback OFF on Port 2 07/07 Loopback ON on Port 2 08/08 Loopback OFF on Port 3 09/09 Loopback ON on Port 3 10/0A Loopback OFF on Port 4 11/0B Loopback ON on Port 4 12/0C Loopback OFF on Port 5 13/0D Loopback ON on Port 5 14/0E Loopback OFF on Port 6 15/0F Loopback ON on Port 6 16/10 Loopback OFF on Port 7 17/11 Loopback ON on Port 7 18/12 Loopback OFF on Port 8 19/13 Loopback ON on Port 8 20/14 Loopback OFF on Port 9 21/15 Loopback ON on Port 9 22/16 Loopback OFF on Port 10 23/17 Loopback ON on Port 10 24/18 Loopback OFF on Port 11 25/19 Loopback ON on Port 11 26/1A Loopback OFF on Port 12 27/1B Loopback ON on Port 12 28/1C Loopback OFF on Port 13 29/1D Loopback ON on Port 13 30/1E Loopback OFF on Port 14 31/1F Loopback ON on Port 14 32/20 Loopback OFF on Port 15 33/21 Loopback ON on Port 15 34/22 Loopback OFF on Port 16 35/23 Loopback ON on Port 16 37/25 Loopback ALL on Ports 1-8 39/27 Loopback ALL on Ports 9-16 40/28 Alternate Mode on Channel Module #1 41/29 Normal Mode on Channel Module #1 42/2A Alternate Mode on Channel Module #2 43/2B Normal Mode on Channel Module #2 45/2D Configuration Load Module #1 47/2F Configuration Load Module #2 ======================================================
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmSlotTrapMask 1.3.6.1.4.1.22.51.2.2.1.10
When the value is 1, no more traps from that slot are sent, until next reset. (temporary mask)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-mask(0), mask(1)  

pfmSlotTrapMask 1.3.6.1.4.1.22.51.2.2.1.11
When the value is 1, no more traps for that slot will be sent, starting after next reset (permanent mask)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-mask(0), mask(1)  

fmSlotIpAddr 1.3.6.1.4.1.22.51.2.2.1.12
IP address of a channel card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

fmSlotMngAccess 1.3.6.1.4.1.22.51.2.2.1.13
This run-time object determines through which interface the SNMP management will be permitted. The default is through the managment bus, via the ESM. This object value is reinitialized to its permanent value after system reset. Setting the object is permitted only for slots containing active SNMP managers. Such cards will change management access immediately according to the specified value. Set values must be either Management-Bus or LAN and the target slot must contain an active SNMP agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-SNMP-management(1), lan(2), management-bus(3)  

pfmSlotMngAccess 1.3.6.1.4.1.22.51.2.2.1.14
This permanent object determines through which interface the SNMP management will be permitted. The default is through the managment bus, via the ESM. This object has no effect on slots not containing SNMP agents. The run-time object will receive this value after system reset only if the value is permitted. Setting the object is permitted only for slots containing active SNMP managers. Such cards will change management access only the next time the card is initialized. Set values must be either Management-Bus or LAN and the target slot must contain an active SNMP agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-SNMP-management(1), lan(2), management-bus(3)  

fmSlotEntityIndex 1.3.6.1.4.1.22.51.2.2.1.15
This object determines the Entity index which the card is a memeber in.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fmSlotCommunity 1.3.6.1.4.1.22.51.2.2.1.16
This object determines the Entity Community which the card is a memeber in.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fmSlotEntityManager 1.3.6.1.4.1.22.51.2.2.1.17
This object determines if the card is an SNMP-manageable Entity Manager.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-entity-manager(1), sNMP-entity-manager(2)  

fmLUID 1.3.6.1.4.1.22.51.3.1
Logic unit ID
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unconfig(0), none(1), lu100(2), lu101(3), lu102(4), lu103(5), lu104(6), lu105(7), lu106(8), lu107(9), lu108(10)  

fmLUDescr 1.3.6.1.4.1.22.51.3.2
Ascii string. Description of the logic unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fmLUStatus 1.3.6.1.4.1.22.51.3.3
One byte of LU status
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

fmLULinkSelect 1.3.6.1.4.1.22.51.3.4
Setup LU link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER main-link(0), sec-link(1)  

fmLULoopBackSet 1.3.6.1.4.1.22.51.3.5
Upon writing, performs LLB command. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmLULoopBackClr 1.3.6.1.4.1.22.51.3.6
Upon writing, clear LLB command. When reading the instance of this object the value has no meaning.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fmLUTrapMask 1.3.6.1.4.1.22.51.3.7
When the value is 1, no more traps from the LU are sent, until next reset. (temporary mask)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-mask(0), mask(1)  

pfmLUTrapMask 1.3.6.1.4.1.22.51.3.8
When the value is 1, no more traps for the LU will be sent, starting after next reset (permanent mask)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-mask(0), mask(1)  

fmDiagConfig 1.3.6.1.4.1.22.51.5.1
Version of the station. The version includes station type, hardware version and software version. The string can include CR and LF
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

fmDiagTrapInfo 1.3.6.1.4.1.22.51.5.2
Used for generic traps. The first word is the trap code. The rest of the string is the extra information. Contains CR and LF char.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

fmDiagFaultTable 1.3.6.1.4.1.22.51.5.3
Table of fault reports from the agent
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FmDiagFaultEntry

fmDiagFaultEntry 1.3.6.1.4.1.22.51.5.3.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  FmDiagFaultEntry  

fmDiagFaultIndex 1.3.6.1.4.1.22.51.5.3.1.1
The fault index in the fault table
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

fmDiagFaultReport 1.3.6.1.4.1.22.51.5.3.1.2
Get the faults detected by the agent
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

fmDiagDebug 1.3.6.1.4.1.22.51.5.4
This object is for factory use only. Users must not write into this variable or improper operation can occur.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal-mode(0), debug-mode(1)  

fmLUOutOfSync 7
Issued when the Logic unit goes out of synchronization
TRAP-TYPE    

fmLUReturnToSync 8
Issues as soon as the logic unit returns to synchronization
TRAP-TYPE    

fmLUPassToMain 9
Issues as soon as the logic unit pass to main link
TRAP-TYPE    

fmLUPassToSecond 10
Issues as soon as the logic unit pass to second link
TRAP-TYPE    

fmLUPrimaryLinkFail 11
When primary link of the logic unit fails this trap is issued
TRAP-TYPE    

fmLUPrimaryLinkOK 12
When primary link of the logic unit fails this trap is issued
TRAP-TYPE    

fmLUSecondLinkFail 13
When second link of the logic unit fails this trap is issued
TRAP-TYPE    

fmLUSecondLinkOK 14
When second link of the logic unit fails this trap is issued
TRAP-TYPE    

fmLULLBOn 15
When the logic unit enters LLB mode
TRAP-TYPE    

fmLULLBOff 16
When the logic unit exits LLB mode
TRAP-TYPE    

fmLUChangeConfig 20
Issues when a change in the LU configuration is done
TRAP-TYPE    

fmSlotTrap 25
Generated when a significant status has changed in a slot. By xoring the 2 statuses, the NMS can identify the cause of the trap.
TRAP-TYPE    

fmSlotChangeConfig 26
Issued when the system detects changes in its slots configuration
TRAP-TYPE    

fmDiagGenericTrap 30
Generic Trap information
TRAP-TYPE    

gigaPhyResourceTable 1.3.6.1.4.1.22.101.6.1.1.1
This table maps resources to backplane segments/ring numbers
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GigaPhyResourceEntry

gigaPhyResourceEntry 1.3.6.1.4.1.22.101.6.1.1.1.1
This table maps resources to backplane segments/ring numbers
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GigaPhyResourceEntry  

gigaPhyResLocationType 1.3.6.1.4.1.22.101.6.1.1.1.1.1
A unique integer representing the location type index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gigaPhyResLocation 1.3.6.1.4.1.22.101.6.1.1.1.1.2
A unique integer representing the location type instance
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gigaPhyResIndex 1.3.6.1.4.1.22.101.6.1.1.1.1.3
A unique integer representing the resource instance at this location
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gigaPhyResType 1.3.6.1.4.1.22.101.6.1.1.1.1.4
The type of resource.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

gigaPhyResCapability 1.3.6.1.4.1.22.101.6.1.1.1.1.5
A unique integer representing the resource capability for attachment to the serial busses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-bus(1), esb(17), eb2(19), eb2-one(20), eb2-two(21), eb2-three(22), eb2-four(23), tr-4M(33), tr-16M(34), fddi-100M(49)  

gigaPhyResSegRing 1.3.6.1.4.1.22.101.6.1.1.1.1.6
A unique integer representing the ring or segment number in which the resource is attached to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

gigaEbmTable 1.3.6.1.4.1.22.101.6.1.1.2
A list of EBM cards entries, one for each EBM card in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GigaEbmEntry

gigaEbmEntry 1.3.6.1.4.1.22.101.6.1.1.2.1
Values for a EBM card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GigaEbmEntry  

gigaEbmIndex 1.3.6.1.4.1.22.101.6.1.1.2.1.1
An index value that uniquely identifies a EBM card
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gigaEbmDescr 1.3.6.1.4.1.22.101.6.1.1.2.1.2
A textual description of the EBM card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

gigaEbmOperStatus 1.3.6.1.4.1.22.101.6.1.1.2.1.3
Actual status of the EBM card: - unknown(1) - don't have the information - empty(2) - no EBM card installed in slot - bad(3) - unable to work due to failure - good(4) - the card is good - active(5) - the card is good and active
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), bad(3), good(4), active(5)  

chasInfo 1.3.6.1.4.1.22.101.6.1.2.1
OBJECT IDENTIFIER    

chasPhysical 1.3.6.1.4.1.22.101.6.1.2.2
OBJECT IDENTIFIER    

chasEntity 1.3.6.1.4.1.22.101.6.1.2.3
OBJECT IDENTIFIER    

chasResource 1.3.6.1.4.1.22.101.6.1.2.4
OBJECT IDENTIFIER    

chasPowerSupply 1.3.6.1.4.1.22.101.6.1.2.5
OBJECT IDENTIFIER    

chasEnviron 1.3.6.1.4.1.22.101.6.1.2.6
OBJECT IDENTIFIER    

chasKnownTypes 1.3.6.1.4.1.22.101.6.1.2.7
OBJECT IDENTIFIER    

chasLocationTypes 1.3.6.1.4.1.22.101.6.1.2.7.1
OBJECT IDENTIFIER    

chasModularSlot 1.3.6.1.4.1.22.101.6.1.2.7.1.1
OBJECT IDENTIFIER    

chasPowerSupplyBay 1.3.6.1.4.1.22.101.6.1.2.7.1.2
OBJECT IDENTIFIER    

chasFanTray 1.3.6.1.4.1.22.101.6.1.2.7.1.3
OBJECT IDENTIFIER    

chasBackplane 1.3.6.1.4.1.22.101.6.1.2.7.1.4
OBJECT IDENTIFIER    

chasFrontSlot 1.3.6.1.4.1.22.101.6.1.2.7.1.5
OBJECT IDENTIFIER    

chasBackSlot 1.3.6.1.4.1.22.101.6.1.2.7.1.6
OBJECT IDENTIFIER    

chasModuleTypes 1.3.6.1.4.1.22.101.6.1.2.7.2
OBJECT IDENTIFIER    

chasLocationEmpty 1.3.6.1.4.1.22.101.6.1.2.7.2.1
OBJECT IDENTIFIER    

chasModuleUnknown 1.3.6.1.4.1.22.101.6.1.2.7.2.2
OBJECT IDENTIFIER    

chasEntityTypes 1.3.6.1.4.1.22.101.6.1.2.7.3
OBJECT IDENTIFIER    

chasChassisEntities 1.3.6.1.4.1.22.101.6.1.2.7.3.1
OBJECT IDENTIFIER    

chasPowerSource 1.3.6.1.4.1.22.101.6.1.2.7.3.1.1
OBJECT IDENTIFIER    

chasChassis 1.3.6.1.4.1.22.101.6.1.2.7.3.1.2
OBJECT IDENTIFIER    

chasMonitor 1.3.6.1.4.1.22.101.6.1.2.7.3.1.3
OBJECT IDENTIFIER    

chasNetEntities 1.3.6.1.4.1.22.101.6.1.2.7.3.2
OBJECT IDENTIFIER    

chas8023Repeater 1.3.6.1.4.1.22.101.6.1.2.7.3.2.1
OBJECT IDENTIFIER    

chas8025Ring 1.3.6.1.4.1.22.101.6.1.2.7.3.2.2
OBJECT IDENTIFIER    

chasFddiRing 1.3.6.1.4.1.22.101.6.1.2.7.3.2.3
OBJECT IDENTIFIER    

chasAtmSwitch 1.3.6.1.4.1.22.101.6.1.2.7.3.2.4
OBJECT IDENTIFIER    

chasFrameRelay 1.3.6.1.4.1.22.101.6.1.2.7.3.2.5
OBJECT IDENTIFIER    

chasEthSwitch 1.3.6.1.4.1.22.101.6.1.2.7.3.2.6
OBJECT IDENTIFIER    

chasConnectEntities 1.3.6.1.4.1.22.101.6.1.2.7.3.3
OBJECT IDENTIFIER    

chasBridge 1.3.6.1.4.1.22.101.6.1.2.7.3.3.1
OBJECT IDENTIFIER    

chasRouter 1.3.6.1.4.1.22.101.6.1.2.7.3.3.2
OBJECT IDENTIFIER    

chasBrouter 1.3.6.1.4.1.22.101.6.1.2.7.3.3.3
OBJECT IDENTIFIER    

chasGateway 1.3.6.1.4.1.22.101.6.1.2.7.3.3.4
OBJECT IDENTIFIER    

chasResTypes 1.3.6.1.4.1.22.101.6.1.2.7.4
OBJECT IDENTIFIER    

chasChassisRes 1.3.6.1.4.1.22.101.6.1.2.7.4.1
OBJECT IDENTIFIER    

chasNetworkRes 1.3.6.1.4.1.22.101.6.1.2.7.4.2
OBJECT IDENTIFIER    

chas8023RptrPort 1.3.6.1.4.1.22.101.6.1.2.7.4.2.1
OBJECT IDENTIFIER    

chas8025MauPort 1.3.6.1.4.1.22.101.6.1.2.7.4.2.2
OBJECT IDENTIFIER    

chasFddiPort 1.3.6.1.4.1.22.101.6.1.2.7.4.2.3
OBJECT IDENTIFIER    

chasAtmPort 1.3.6.1.4.1.22.101.6.1.2.7.4.2.4
OBJECT IDENTIFIER    

chas8023PortGroup 1.3.6.1.4.1.22.101.6.1.2.7.4.2.5
OBJECT IDENTIFIER    

chas8025PortGroup 1.3.6.1.4.1.22.101.6.1.2.7.4.2.6
OBJECT IDENTIFIER    

chasFddiPortGroup 1.3.6.1.4.1.22.101.6.1.2.7.4.2.7
OBJECT IDENTIFIER    

chasAtmPortGroup 1.3.6.1.4.1.22.101.6.1.2.7.4.2.8
OBJECT IDENTIFIER    

chasBplaneRes 1.3.6.1.4.1.22.101.6.1.2.7.4.3
OBJECT IDENTIFIER    

chas8023Bplane 1.3.6.1.4.1.22.101.6.1.2.7.4.3.1
OBJECT IDENTIFIER    

chas8025Bplane 1.3.6.1.4.1.22.101.6.1.2.7.4.3.2
OBJECT IDENTIFIER    

chasFddiBplane 1.3.6.1.4.1.22.101.6.1.2.7.4.3.3
OBJECT IDENTIFIER    

chasMgmtBplane 1.3.6.1.4.1.22.101.6.1.2.7.4.3.4
OBJECT IDENTIFIER    

chasAtmBplane 1.3.6.1.4.1.22.101.6.1.2.7.4.3.5
OBJECT IDENTIFIER    

chasConnectRes 1.3.6.1.4.1.22.101.6.1.2.7.4.4
OBJECT IDENTIFIER    

chasBridgeRelay 1.3.6.1.4.1.22.101.6.1.2.7.4.4.1
OBJECT IDENTIFIER    

chasRouterRelay 1.3.6.1.4.1.22.101.6.1.2.7.4.4.2
OBJECT IDENTIFIER    

chasBrouterRelay 1.3.6.1.4.1.22.101.6.1.2.7.4.4.3
OBJECT IDENTIFIER    

chasSwitch 1.3.6.1.4.1.22.101.6.1.2.7.4.4.4
OBJECT IDENTIFIER    

wellKnownSensors 1.3.6.1.4.1.22.101.6.1.2.7.5
OBJECT IDENTIFIER    

sensorOther 1.3.6.1.4.1.22.101.6.1.2.7.5.1
OBJECT IDENTIFIER    

sensorTemperature 1.3.6.1.4.1.22.101.6.1.2.7.5.2
OBJECT IDENTIFIER    

sensorFans 1.3.6.1.4.1.22.101.6.1.2.7.5.3
OBJECT IDENTIFIER    

sensorHumidity 1.3.6.1.4.1.22.101.6.1.2.7.5.4
OBJECT IDENTIFIER    

chasType 1.3.6.1.4.1.22.101.6.1.2.1.1
An authoritative identification of the type of hub-based or standalone chassis. By convention this value is allocated within the SMI enterprises subtree(1.3.6.1.4.1), and provides an easy and unambiguous means for determining `what kind of box' is being managed. If this information is not present or unknown, its value should be set to the value: chasTypeUnknown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

chasPhysicalChanges 1.3.6.1.4.1.22.101.6.1.2.1.2
The number of physical changes that have occurred in the chassis since the agent was warm/cold started. This includes additions and removal of modules and entities. Other uses are implementation specific.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chasChassisSerialNumber 1.3.6.1.4.1.22.101.6.1.2.1.3
The serial number of the chassis. If no serial number is available then this object should be the zero length string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

chasMultiConf 1.3.6.1.4.1.22.101.6.1.2.1.4
Which type of MultiHUB is installed in the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), none(2), half(3), full(4)  

chasPhyLocationTable 1.3.6.1.4.1.22.101.6.1.2.2.1
This table summarises the different classes of and types of modular physical locations in the chassis. This includes but is not limited to slot within a chassis, power supply bay.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasPhyLocationEntry

chasPhyLocationEntry 1.3.6.1.4.1.22.101.6.1.2.2.1.1
An entry in the phyLocationTable
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChasPhyLocationEntry  

chasPhyLocationTypeIndex 1.3.6.1.4.1.22.101.6.1.2.2.1.1.1
This uniquely identifies the physical location type within the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

chasPhyLocationCount 1.3.6.1.4.1.22.101.6.1.2.2.1.1.2
This defines the number of physical locations of this type exist within the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

chasPhyLocationType 1.3.6.1.4.1.22.101.6.1.2.2.1.1.3
Uniquely identifies the 'type' of the physical location within the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

chasPhyLocationDescr 1.3.6.1.4.1.22.101.6.1.2.2.1.1.4
Each type of physical location within the chassis is given a textual name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

chasPhyModuleTable 1.3.6.1.4.1.22.101.6.1.2.2.2
This table defines the physical modules within a chassis. This is done by defining the type physical modules and the physical location where it resides. This table also provides a mapping between physical modules and their location within the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasPhyModuleEntry

chasPhyModuleEntry 1.3.6.1.4.1.22.101.6.1.2.2.2.1
An entry in this table that describes a physical module that resides at a given physcial location within the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChasPhyModuleEntry  

chasPhyModuleLocationType 1.3.6.1.4.1.22.101.6.1.2.2.2.1.1
An instance of a module is identified by the physical location in which it resides. The physical location is identified by location type index and location index (instance of that location type). This object defines an instance of the chasPhyLocationType.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPhyModuleLocation 1.3.6.1.4.1.22.101.6.1.2.2.2.1.2
An instance of a module is identified by the physical location which it resides. The physical location is identified by location type index and location index (instance of that location type). This object defines the instance of a particular location type. It must be within the bounds defined by chasPhyLocationCount.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPhyModuleType 1.3.6.1.4.1.22.101.6.1.2.2.2.1.3
An authoritative identification of the type of physcial module in this physical location. A value of chasModuleUnknown indicates that the type of physical module is unknown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

chasPhyModuleSwVersion 1.3.6.1.4.1.22.101.6.1.2.2.2.1.4
A textual description of the version/revision level for this module's software. If not realized this value should be set to the zero-length string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

chasPhyModuleHwVersion 1.3.6.1.4.1.22.101.6.1.2.2.2.1.5
A textual description of the version/revision level for this module's firmware. If not realized this value should be set to the zero-length string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

chasPhyModuleSerialNumber 1.3.6.1.4.1.22.101.6.1.2.2.2.1.6
The serial number of the physical module present in this physical location. If the physical location table is implemented as dense and the slot is empty this value will be the zero length string. If no serial number is available for a physical module this value should set to a zero length string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

chasPhyModuleDescription 1.3.6.1.4.1.22.101.6.1.2.2.2.1.7
A textual description of the physical module plugged that resides in this physical location. If not available this value should be set to a zero length string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

chasPhyModuleLastChangeTime 1.3.6.1.4.1.22.101.6.1.2.2.2.1.8
The value of MIB-II's sysUpTime (in the agent supporting this chassis MIB) at which a module was last inserted or initialized. If the module has not changed since the last network managment system reinitialized then this object has a zero value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

chasPhyModuleAdminStatus 1.3.6.1.4.1.22.101.6.1.2.2.2.1.9
Provides desired state of the given physical module. Notice that not all values may be supported by the specified physical module. In this case and SNMP error will be returned when the set is attempted. A physical module maybe activated by writing a value of enable(2). A physical module may be de-activated by writing a value of disable(3). In a disabled state a physical module is present in the chassis but is benign. Writing a value of sw-reset(4) initiates a software reset sequence. Writing a value of hw-reset(7) initiates a hardware reset sequence. A value of programLoad(5) initiates a software load sequence. Writing a value of test(6) should start a self test sequence within the physical module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), enable(2), disable(3), sw-reset(4), programLoad(5), test(6), hw-reset(7)  

chasPhyModuleOperStatus 1.3.6.1.4.1.22.101.6.1.2.2.2.1.10
Provides operational status of the module. The following are possible definitions of the values. The exact definition of the values is implementation specific. A value of other(1) implies some undetermined state, possibly as a result of setting phyAdminStatus to a value of disable(3). A value of invalid(2) could have the possible meaning that the module exists but the chassis manager has no direct control over the module. A value of testing(3) may be a diagnostic state. A value of operational(4) implies that the entity is running with no errors or warnings. State resetInProgress(5) implies equivalent of setting phyAdminStatus to reset(4). The states of warning(6), nonFatalError(7), fatalError(8) reflect conditions detected during operation. The entity may or may not be still functional. For example if a modules value of phyAdminStatus is disable(3) and is set to enable(2) then phyOperStatus may enter a state of testing(3) then change to a value of operational(4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), invalid(2), test(3), operational(4), resetInProgress(5), warning(6), nonFatalError(7), fatalError(8), programLoad(9)  

chasEntityTable 1.3.6.1.4.1.22.101.6.1.2.3.1
A table that contains information about the 'logical' networking devices (entities) in this chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasEntityEntry

chasEntityEntry 1.3.6.1.4.1.22.101.6.1.2.3.1.1
Information concerning an entity in the chassis. Conceptual rows may not be created or deleted with SNMP operations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChasEntityEntry  

chasEntityIndex 1.3.6.1.4.1.22.101.6.1.2.3.1.1.1
A unique index for the entity for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

chasEntityObjectID 1.3.6.1.4.1.22.101.6.1.2.3.1.1.2
The specific type of entity. The value of this object is analagous to MIB-II's sysObjectId. In particular, it has the same value as would be returned if the SNMP Party (identified by chasEntityParty) and/or the community (identified by chasIpAddress and chasCommunity), were queried for sysObjectId.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

chasEntityDescr 1.3.6.1.4.1.22.101.6.1.2.3.1.1.3
A textual description of the entity. The value of this object is analagous to MIB-II's sysDescr. In particular, it has the same value as would be returned if the SNMP Party (identified by chasEntityParty) and/or the community (identified by chasIpAddress and chasCommunity), were queried for sysDescr.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

chasEntityAdminStatus 1.3.6.1.4.1.22.101.6.1.2.3.1.1.4
Provides the administratively desired state of the given entity. An entity is activated by writing a value of enable(2). An entity may be de-activated by writing a value of disable(3). In a disabled state, a entity does exist within the given chassis, but is benign. A disabled entity is available for subsequent activation. Writing a value of reset(4) specifies an entity should initiate a reset sequence. Writing a value of programload(5) specifies an entity should initiate a program load sequence. Writing a value of test(6) specifies an entity should initiate a testing sequence. Agent support of the writing of any of the values of this object is implementation-specific. For example, this object might be read only for entities that disabling would compromise the integrity of the chassis.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), enable(2), disable(3), reset(4), programload(5), test(6)  

chasEntityOperStatus 1.3.6.1.4.1.22.101.6.1.2.3.1.1.5
Provides operational status of the entity. The following are possible definitions of the values. The exact definition of the values is implementation specific. A value of other(1) implies some undetermined state, possibly as a result of setting chasEntityAdminStatus to a value of disable(3). A value of invalid(2) could have the possible meaning that the entity exists but the chassis manager has no direct control of the entity. A value of testing(3) may be a diagnostic state. A value of operational(4) implies that the entity is running with no errors or warnings. State resetInProgress(5) implies equivalent of setting chasEntityAdminStatus to reset(4). The states of warning(6), nonFatalError(7), fatalError(8) reflect conditions detected during operation. The entity may or may not be still functional. State loading(10) is a result of asserting programload(5) in chasEntityAdminStatus. For example if an entities value of chasEntityAdminStatus is disable(3) and is set to enable(2) then chasEntityOperStatus may enter a state of testing(3) then change to a value of operational(4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), invalid(2), testing(3), operational(4), resetInProgress(5), warning(6), nonFatalError(7), fatalError(8), loading(10)  

chasEntityTimeStamp 1.3.6.1.4.1.22.101.6.1.2.3.1.1.6
The value of MIB-II's sysUpTime (in the agent supporting this MIB) at which this entity was last (re-)initialized. If the entity has not been initialized then this object has a zero value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

chasEntityParty 1.3.6.1.4.1.22.101.6.1.2.3.1.1.7
The SNMP Party which provides access to the detailed management information for this entity. Note that the definition of a SNMP Party includes the location at which it executes, the authentication and privacy algorithms and parameters required to access the management entity. In order for a SNMP manager to be able to access the Party, that manager must have prior knowledge of the Party. A party is named by a 'Party'. For a entity which is not managed through access to a SNMP Party, the value of this object is 0.0
Status: mandatory Access: read-only
OBJECT-TYPE    
  Party  

chasEntityContext 1.3.6.1.4.1.22.101.6.1.2.3.1.1.8
The SNMPv2 Context indentifier the chasEntityContext in conjunction with chasEntityParty defines access to the MIB view for this entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Context  

chasEntityCommunity 1.3.6.1.4.1.22.101.6.1.2.3.1.1.9
The SNMP Community which executes at the address chasEntityIpAddress, and provides access to the detailed management information for this entity. For a entity which is not managed through access to a SNMP Community, the value of this object is the zero-length string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

chasEntityIpAddress 1.3.6.1.4.1.22.101.6.1.2.3.1.1.10
The address of the SNMP agent which responds to messages for the SNMP Community identified by chasEntityCommunity. When access is via proxy, this variable contains the address of the proxy agent. For a entity which is not managed through access to a SNMP Community, the value of this object is 0.0.0.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

chasPhyResourceTable 1.3.6.1.4.1.22.101.6.1.2.4.1
This table defines a physical relationship between physical modules and resources. A resource is a building block. A resource defines the type of relationship between entities. This may be a back plane connection between physical modules sharing the same entity. It may be a network segment that connects multiple entities. This table then defines the physical mapping of resources and physical modules onto entities.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasPhyResourceEntry

chasPhyResourceEntry 1.3.6.1.4.1.22.101.6.1.2.4.1.1
Defines a particular physical configuration relationship.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ChasPhyResourceEntry  

chasPhyResLocationType 1.3.6.1.4.1.22.101.6.1.2.4.1.1.1
A resource exists on a particular module. A module is identified by it's physical location. Physical location is defined by location type and an instance of that physical location type. This object defines the location type. This object can be used in conjunction with chasPhyResLocation to index the module table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPhyResLocation 1.3.6.1.4.1.22.101.6.1.2.4.1.1.2
A resource exists on a particular module. A module is identified by it's physical location. Physical location is defined by location type and an instance of that physical location type. This object defines a particular instance of the physical location.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPhyResIndex 1.3.6.1.4.1.22.101.6.1.2.4.1.1.3
A unique index for the chassis resource on this particular physical module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPhyResType 1.3.6.1.4.1.22.101.6.1.2.4.1.1.4
The type of resource.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

chasPhyResAssignment 1.3.6.1.4.1.22.101.6.1.2.4.1.1.5
The physical module resource is assigned to a specific entity. This object defines the entity to which this resource is currently assigned. Notice, not all implementations may support this object as read-write. If read-write is supported assignment may still fail due to a number of reasons such as insufficient resources, invalid configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPhyResEntitySubIndex 1.3.6.1.4.1.22.101.6.1.2.4.1.1.6
Provides a unique index that can be used to identify the relationship in terms of the entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasLogResourceTable 1.3.6.1.4.1.22.101.6.1.2.4.2
Defines a logical configuration relationship which is a relationship between entities and resources and the physical module that the relationship exists on.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasLogResourceEntry

chasLogResourceEntry 1.3.6.1.4.1.22.101.6.1.2.4.2.1
Defines a single logical relationship.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChasLogResourceEntry  

chasLogResEntity 1.3.6.1.4.1.22.101.6.1.2.4.2.1.1
The entity ID for which this logical configuration relationship exists.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasLogResEntitySubIndex 1.3.6.1.4.1.22.101.6.1.2.4.2.1.2
The entity sub index for which this logical configuration relationship exists. The logical relationship is identified by a resource assignment to an entity. The sub index defines a particular instance of the mapping of physical configuration onto an entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasLogResLocationType 1.3.6.1.4.1.22.101.6.1.2.4.2.1.3
A module is defined by it's physical location type and an instance of that physical location. This object defines the physical location type portion of the physical module identifier that this logical configuration exists for.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasLogResLocation 1.3.6.1.4.1.22.101.6.1.2.4.2.1.4
A module is defined by it's physical location type and an instance of that physical location. This object defines the instance physical location (location index) portion of the physical module identifier that this logical configuration exists for.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasLogResIndex 1.3.6.1.4.1.22.101.6.1.2.4.2.1.5
The value of this object refers to a particular instance of a resource, as defined by chasResourceIndex, for which this relationship is defined. This together with chasLogResLocationType and chasLogResLocation completes the mapping of the logical configuration on to the physical module and resource combination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPowerSupplyTable 1.3.6.1.4.1.22.101.6.1.2.5.1
A list of power supply entries, one for each power supply in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasPowerSupplyEntry

chasPowerSupplyEntry 1.3.6.1.4.1.22.101.6.1.2.5.1.1
Values for a power supply.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChasPowerSupplyEntry  

chasPowerSupplyIndex 1.3.6.1.4.1.22.101.6.1.2.5.1.1.1
An index value that uniquely identifies a power supply. This may correspond to a hardware power supply slot, which may or may not be the same as a network device slot (chasSlotIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPowerSupplyDescr 1.3.6.1.4.1.22.101.6.1.2.5.1.1.2
A textual description of the power supply, including the vendor's name and version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

chasPowerSupplyAdminStatus 1.3.6.1.4.1.22.101.6.1.2.5.1.1.3
Desired status of the power supply.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), enable(2), disable(3)  

chasPowerSupplyOperStatus 1.3.6.1.4.1.22.101.6.1.2.5.1.1.4
Actual status of the power supply: - unknown(1) - status not known. - empty(2) - no power supply installed in slot - disabled(3) - unable to supply power due to chasPowerSupplyAdminStatus - bad(4) - unable to supply power due to failure - warning(5) - supplying power but an output or sensor is bad or warning - standby(6) - believed usable but not supplying power - engaged(7) - supplying power - redundant(8) - supplying power but not needed It is an implementation specific matter whether the agent keeps entries with status unknown(1) or empty(2) in the table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), disabled(3), bad(4), warning(5), standby(6), engaged(7), redundant(8)  

chasPowerSupplyHealthText 1.3.6.1.4.1.22.101.6.1.2.5.1.1.5
A textual description of the power supply's operational status. Agents may use this string to provide detailed information on current failures, including how they were detected, and/or instructions for problem resolution. The contents are agent-specific.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

chasPowerSupplyWarnings 1.3.6.1.4.1.22.101.6.1.2.5.1.1.6
The number of times chasPowerSupplyOperStatus has gone to warning(5).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chasPowerSupplyFailures 1.3.6.1.4.1.22.101.6.1.2.5.1.1.7
The number of times chasPowerSupplyOperStatus has gone to bad(4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chasPowerSupplyLocationType 1.3.6.1.4.1.22.101.6.1.2.5.1.1.8
This defines the instance of a physical location type of the power supply. Location Type together with location index completely defines the location of a power supply.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPowerSupplyLocationIndex 1.3.6.1.4.1.22.101.6.1.2.5.1.1.9
Defines a particular instance of a physical location type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPowerSupplyOutputTable 1.3.6.1.4.1.22.101.6.1.2.5.2
A list of power supply output entries, one for each output of each power supply in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasPowerSupplyOutputEntry

chasPowerSupplyOutputEntry 1.3.6.1.4.1.22.101.6.1.2.5.2.1
Values for a power supply output.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChasPowerSupplyEntry  

chasPowerSupplyIdIndex 1.3.6.1.4.1.22.101.6.1.2.5.2.1.1
An index value that uniquely identifies a power supply. This may correspond to a hardware power supply slot, which may or may not be the same as a network device slot (chasSlotIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPowerSupplyOutputIndex 1.3.6.1.4.1.22.101.6.1.2.5.2.1.2
An index value that uniquely identifies an output for the power supply.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPowerSupplyOutputStatus 1.3.6.1.4.1.22.101.6.1.2.5.2.1.3
Actual status of the power supply: - unknown(1) status not known - bad(2) unable to supply power due to failure - warning(3) supplying power but marginally - good(4) supplying power It is an implementation specific matter whether the agent keeps entries with status unknown(1) in the table. If unknown(1), offered values and counters are meaningless.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), bad(2), warning(3), good(4)  

chasPowerSupplyOutputNominalVoltage 1.3.6.1.4.1.22.101.6.1.2.5.2.1.4
In hundredths of a volt, the voltage the output is supposed to supply, such as -5, +5, +12, -15, etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPowerSupplyOutputOfferedVoltage 1.3.6.1.4.1.22.101.6.1.2.5.2.1.5
In hundredths of a volt, the voltage actually offered by the output. If chasPowerSupplyOutputStatus is good(4), the value 0 means offered voltage is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPowerSupplyOutputOfferedWattage 1.3.6.1.4.1.22.101.6.1.2.5.2.1.6
In hundredths of a watt, the wattage actually offered by the output. If chasPowerSupplyOutputStatus is good(4), the value 0 means offered wattage is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasPowerSupplyOutputWarnings 1.3.6.1.4.1.22.101.6.1.2.5.2.1.7
The number of times chasPowerSupplyOutputStatus has gone to warning(3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chasPowerSupplyOutputFailures 1.3.6.1.4.1.22.101.6.1.2.5.2.1.8
The number of times chasPowerSupplyOutputStatus has gone to bad(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chasEnvironTable 1.3.6.1.4.1.22.101.6.1.2.6.1
A list of environmental entries, one for each environmental sensor in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasEnvironEntry

chasEnvironEntry 1.3.6.1.4.1.22.101.6.1.2.6.1.1
Values for a environmental sensor.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChasEnvironEntry  

chasEnvironSensor 1.3.6.1.4.1.22.101.6.1.2.6.1.1.1
The identification of an environmental sensor. Other AutonomousType values may be defined elsewhere, in association with specific protocols. However, this document assigns those of known interest as of this writing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  AutonomousType  

chasEnvironStatus 1.3.6.1.4.1.22.101.6.1.2.6.1.1.2
Actual status indicated by the sensor. It is an implementation specific matter whether the agent keeps entries with status unknown(1) in the table. If unknown(1), counters are meaningless.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), bad(2), warning(3), good(4)  

chasEnvironWarnings 1.3.6.1.4.1.22.101.6.1.2.6.1.1.3
The number of times chasEnvironStatus has gone to warning(3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chasEnvironFailures 1.3.6.1.4.1.22.101.6.1.2.6.1.1.4
The number of times chasEnvironStatus has gone to bad(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chasEnvironLocationType 1.3.6.1.4.1.22.101.6.1.2.6.1.1.5
Defines the actual type of physical location that this environmental sensor occupies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasEnvironLocationIndex 1.3.6.1.4.1.22.101.6.1.2.6.1.1.6
This defines the particular instance of a physical location type which this environmental sensor occupies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chasEnvironIndex 1.3.6.1.4.1.22.101.6.1.2.6.1.1.7
An index value that uniquely identifies an environmental sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gigaPowerSupplyTrap 31
This trap message is generated as soon as one of the power supply has changed its operational status.
TRAP-TYPE    

gigaSensorTrap 32
This trap message is generated when there is a change in enviromental sensor status.
TRAP-TYPE    

gigaHostAuthTrap 33
This trap is generated when an unauthorized host attempts to perform an SNMP SET operation.
TRAP-TYPE    

gigaModuleTrap 34
This trap message is generated when there is a change in module operational status
TRAP-TYPE    

gigaModuleEmptyTrap 35
This trap is generated when a module is removed from a modular slot.
TRAP-TYPE    

gigaModuleNotEmptyTrap 36
This trap is generated when a module is inserted in a modular slot.
TRAP-TYPE    

gigaPhyResAttachChangeTrap 37
This trap is generated when physical module resource is changed it's segment/ring attachment.
TRAP-TYPE    

gigaPhyResConfigChangeTrap 38
This trap is generated when there is a global change in physical module resources configuration.
TRAP-TYPE    

gigaEbmTrap 39
This trap message is generated as soon as one of the EBM cards has changed its operational status.
TRAP-TYPE    

fmSlotIPAddressChange 40
This trap is generated when IP Address is changed in a slot.
TRAP-TYPE