ES1000-MIB

File: ES1000-MIB.mib (57127 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
BRIDGE-MIB RFC-1215

Imported symbols

enterprises TimeTicks Counter
OBJECT-TYPE DisplayString MacAddress
TRAP-TYPE

Defined Types

SwModuleInfoEntry  
SEQUENCE    
  swModuleInfoIndex INTEGER
  swModuleInfoDesc DisplayString
  swModuleInfoType INTEGER
  swModuleInfoTotalNumOfPort INTEGER
  swModuleInfoNumOfPortInUse INTEGER
  swModuleInfoPortLedStatus OCTET STRING

SwPortInfoEntry  
SEQUENCE    
  swPortInfoModuleIndex INTEGER
  swPortInfoPortIndex INTEGER
  swPortInfoType INTEGER
  swPortInfoLinkStatus INTEGER
  swPortInfoNwayStatus INTEGER
  swPortInfoFlowCtrlStatus INTEGER

SwPortCtrlEntry  
SEQUENCE    
  swPortCtrlModuleIndex INTEGER
  swPortCtrlPortIndex INTEGER
  swPortCtrlAdminState INTEGER
  swPortCtrlLinkStatusAlarmState INTEGER
  swPortCtrlNwayState INTEGER
  swPortCtrlFlowCtrlState INTEGER
  swPortCtrlBackPressState INTEGER
  swPortCtrlLockState INTEGER
  swPortCtrlPriority INTEGER
  swPortCtrlStpState INTEGER
  swPortCtrlHOLState INTEGER
  swPortCtrlBroadcastRisingThr INTEGER
  swPortCtrlBroadcastFallingThr INTEGER
  swPortCtrlBroadcastRisingAct INTEGER
  swPortCtrlBroadcastFallingAct INTEGER
  swPortCtrlCleanAllStatisticCounter INTEGER

SwPortStEntry  
SEQUENCE    
  swPortStModuleIndex INTEGER
  swPortStPortIndex INTEGER
  swPortStByteRx Counter
  swPortStByteTx Counter
  swPortStFrameRx Counter
  swPortStFrameTx Counter
  swPortStTotalBytesRx Counter
  swPortStTotalFramesRx Counter
  swPortStBroadcastFramesRx Counter
  swPortStMulticastFramesRx Counter
  swPortStCRCError Counter
  swPortStOversizeFrames Counter
  swPortStFragments Counter
  swPortStJabber Counter
  swPortStCollision Counter
  swPortStLateCollision Counter
  swPortStFrames-64-bytes Counter
  swPortStFrames-65-127-bytes Counter
  swPortStFrames-128-255-bytes Counter
  swPortStFrames-256-511-bytes Counter
  swPortStFrames-512-1023-bytes Counter
  swPortStFrames-1024-1536-bytes Counter
  swPortStFramesDroppedFrames Counter
  swPortStMulticastFramesTx Counter
  swPortStBroadcastFramesTx Counter
  swPortStUndersizeFrames Counter

SwFdbStaticEntry  
SEQUENCE    
  swFdbStaticVid INTEGER
  swFdbStaticAddressIndex MacAddress
  swFdbStaticPortMap OCTET STRING
  swFdbStaticState INTEGER
  swFdbStaticStatus INTEGER

SwFdbFilterEntry  
SEQUENCE    
  swFdbFilterVid INTEGER
  swFdbFilterAddressIndex MacAddress
  swFdbFilterState INTEGER

Defined Values

marconi 1.3.6.1.4.1.326
OBJECT IDENTIFIER    

systems 1.3.6.1.4.1.326.2
OBJECT IDENTIFIER    

external 1.3.6.1.4.1.326.2.20
OBJECT IDENTIFIER    


dlinkcommon 1.3.6.1.4.1.326.2.20.1.1
OBJECT IDENTIFIER    

golf 1.3.6.1.4.1.326.2.20.1.2
OBJECT IDENTIFIER    

golfproducts 1.3.6.1.4.1.326.2.20.1.2.1
OBJECT IDENTIFIER    

golfcommon 1.3.6.1.4.1.326.2.20.1.2.2
OBJECT IDENTIFIER    

es1000 1.3.6.1.4.1.326.2.20.1.2.1.1
OBJECT IDENTIFIER    

marconi-products 1.3.6.1.4.1.326.2.20.1.2.2.1
OBJECT IDENTIFIER    

marconi-mgmt 1.3.6.1.4.1.326.2.20.1.2.2.2
OBJECT IDENTIFIER    

marconi-es1000Prod 1.3.6.1.4.1.326.2.20.1.2.2.1.24
OBJECT IDENTIFIER    

swProperty 1.3.6.1.4.1.326.2.20.1.2.2.1.24.1
OBJECT IDENTIFIER    

swModule 1.3.6.1.4.1.326.2.20.1.2.2.1.24.1.1
OBJECT IDENTIFIER    

es1000Series 1.3.6.1.4.1.326.2.20.1.2.2.2.24
OBJECT IDENTIFIER    

swDevPackage 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1
OBJECT IDENTIFIER    

swModulePackage 1.3.6.1.4.1.326.2.20.1.2.2.2.24.2
OBJECT IDENTIFIER    

swPortPackage 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3
OBJECT IDENTIFIER    

swFdbPackage 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4
OBJECT IDENTIFIER    

swDevInfo 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.1
OBJECT IDENTIFIER    

swDevInfoSystemUpTime 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.1.1
The value of sysUpTime at the time the switch entered its current operational state. If the current state was entered prior to the last re-initialization, then this object contains a zero value. This value is in units of seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

swDevInfoMaxNumOfModule 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.1.2
The maximum number of modules in this device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swDevInfoTotalNumOfModule 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.1.3
The current actual number of modules in this device.The values range is 1..swDevInfoMaxNumOfModule.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swDevInfoTotalNumOfPort 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.1.4
The number of ports within this switch. This value is the sum of the ports within this switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swDevInfoNumOfPortInUse 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.1.5
The number of ports in this switch connected to the segment or the end stations.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swDevInfoConsoleInUse 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.1.6
This usage indication of console system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), in-use(2), not-in-use(3)  

swDevInfoSystemLedStatus 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.1.7
This object is a set of system LED indications. The first four octets is defined as system LED. The first LED is power LED. The second LED is console LED. The third LED is GIGA module existing LED. The fourth LED is GIGA module link LED. The other octets following the fourth octets are the port LED. Every two bytes are presented to a port. The first byte is presentd to the Link/Activity LED. The second byte is presented to the Speed LED. There is one byte per LED. The most significant bit is used for blink/solid: Off = The LED is lit permanently. On = The LED blinks. The three least significant bits are used for color: 1 = not lit, 2 = green, 3 = yellow,(orange) 4 = blue, 5 = red, 0+6+7 not used The four remaining bits are currently unused and must be 0. The lastest two octects are defined as slot module type. The first octect is slot 1 module type. The second octect is slot 2 module type, and so on. The module type representation for each byte is listed below: 1 = no slot module, 2 = 1 port BNC, 3 = 2 port Fiber MTRJ, 4 = 2 port TX UTP, 5 = 1 port Fiber SC, 6 = SX Gigabit, 7 = LX Gigabit, 8 = TX Gigabit other not used
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..127)  

swDevInfoSaveCfg 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.1.8
This object indicates the status of the device configuration. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. proceeding(2) - the device configuration is saving into the NV-RAM. completed(3) - all of the device configuration parameters have been saved into NV-RAM. changed-not-save - some of the device configuration parameters have been changed but not saved into NV-RAM. failed(5) - The processing of saving device configuration is failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), proceeding(2), completed(3), changed-not-save(4), failed(5)  

swDevCtrl 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2
OBJECT IDENTIFIER    

swDevCtrlStpState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2.1
This object can be enabled or disabled spanning tree algorithm during runtime of the system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swDevIGMPCaptureState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2.2
This object indicates Internet Group Management Protocol (IGMP) capture function is enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swDevCtrlPartitionModeState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2.3
This object used to enable or disable port auto partition. When the object apply for all ports of the device
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swDevCtrlTableLockState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2.4
This object indicates whether the address table is locked. In other words, the address table doesn't learn any more new address. The aging timer is suspended when the address table is locked. As long as the table is locked, all of the frames are dropped if the destination can not be found in the address. When swVlanInfoStatus is in MAC-Base VLAN mode, this object is always disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swDevCtrlSaveCfg 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2.5
As the object is set, the current device configuration is save into to NV-RAM.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

swDevCtrlHOLState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2.6
The object provides a way to prevent HOL (Head Of Line) blocking between ports. HOL protection may prevent forwarding a packet to a blocking port.The idea relies on the assumption that it is better to discard packets destined to blocking ports, then to let them consume more and more buffers in the input-port's Rx-counters because eventually these input ports may become totally blocked. The meanings of the values are: other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. disabled(2) - HOL function disable for device. enabled(3) - HOL function enable for device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swDevCtrlAddrLookupModesAndHitRate 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2.7
According to the differnet address looke mode setting, to enlarge the address table size is possible in device. But there is side effect as the higher level you have, the lower thorughput device has. That means Level 0 get the smallest table size, but get better performace. We recommand the user use the Level 1 as defualt setting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER level0(1), level1(2), level2(3), level3(4), level4(5), level5(6), level6(7), level7(8)  

swDevCtrlUploadImageFileName 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2.8
The name of the image file to be uploaded from the device to TFTP server when enabling image upload function (by writing swDevCtrlUploadImage).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..64)  

swDevCtrlUploadImage 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.2.9
Image file upload control. Writing it by any value will immediately invoke image upload function.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

swDevAlarm 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.3
OBJECT IDENTIFIER    

swDevAlarmPartition 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.3.1
Depending on this object, the device send a trap or not when any one of the device's ports was partitioned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swDevAlarmNewRoot 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.3.2
When the device has become the new root of the Spanning Tree, this object decide whether to send a new root trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swDevAlarmTopologyChange 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.3.3
This object determine to send a trap or not when the switch topology was changed. If the object is enabled(3), the topologyChange trap is sent by the device when any of its configured ports transitions from the Learning state to the Forwarding state, or from the Forwarding state to the Blocking state. For the same port tranition, the device doesn't send the trap if this object value is disabled or other.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swDevAlarmLinkChange 1.3.6.1.4.1.326.2.20.1.2.2.2.24.1.3.4
This object determine to send a trap or not when the link was changed. If the object is enabled(3), the Link Change trap is sent by the device when any of its ports link change. The device doesn't send the trap if this object value is disabled or other.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swModuleInfoTable 1.3.6.1.4.1.326.2.20.1.2.2.2.24.2.1
A table that contains information about every module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwModuleInfoEntry

swModuleInfoEntry 1.3.6.1.4.1.326.2.20.1.2.2.2.24.2.1.1
A list of information for each module of the device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwModuleInfoEntry  

swModuleInfoIndex 1.3.6.1.4.1.326.2.20.1.2.2.2.24.2.1.1.1
This object indicates switch module number.(1..swDevInfoMaxNumOfModule)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swModuleInfoDesc 1.3.6.1.4.1.326.2.20.1.2.2.2.24.2.1.1.2
A textual description of the module for memorization .
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

swModuleInfoType 1.3.6.1.4.1.326.2.20.1.2.2.2.24.2.1.1.3
This object indicates the type of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), baseModule-UTP(2), optionModule-2PortFiber-MTRJ(3), optionModule-2PortTX-UTP(4), optionModule-1PortFiber-SC(5), optionModule-1000Base-SX(6), optionModule-1000Base-LX(7), optionModule-1000Base-TX(8)  

swModuleInfoTotalNumOfPort 1.3.6.1.4.1.326.2.20.1.2.2.2.24.2.1.1.4
The number of ports within this module. This value is the sum of the ports within this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swModuleInfoNumOfPortInUse 1.3.6.1.4.1.326.2.20.1.2.2.2.24.2.1.1.5
The number of ports in this module connected to the segment or the end stations.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swModuleInfoPortLedStatus 1.3.6.1.4.1.326.2.20.1.2.2.2.24.2.1.1.6
This object is a set of module's port LED indications. Every two bytes are presented to a port. Except the module 3 (Gigabit module) ,the first byte is presentd to the Link/Activity LED. The second byte is presented to the Speed LED. For the module 3 ,the first byte is presentd to the module's existing LED. The second byte is presented to the Link/Activity LED. There is one byte per LED. The most significant bit is used for blink/solid: Off = The LED is lit permanently. On = The LED blinks. The three least significant bits are used for color: 1 = not lit, 2 = green, 3 = yellow,(orange) 4 = blue, 5 = red, 0+6+7 not used The four remaining bits are currently unused and must be 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..127)  

swPortInfoTable 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.1
A table that contains information about every port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwPortInfoEntry

swPortInfoEntry 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.1.1
A list of information for each port of the device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwPortInfoEntry  

swPortInfoModuleIndex 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.1.1.1
This object indicates switch module number.(1..Max module number)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swPortInfoPortIndex 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.1.1.2
This object indicates the module's port number.(1..Max port number in the module)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swPortInfoType 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.1.1.3
This object indicates the connector type of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), portType-UTP(2), portType-AUI(3), portType-Fiber-MTRJ(4), portType-Fiber-SC(5), portType-BNC(6)  

swPortInfoLinkStatus 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.1.1.4
This object indicates the port link status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), link-pass(2), link-fail(3)  

swPortInfoNwayStatus 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.1.1.5
This object indicates the port speed and duplex mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), half-10Mbps(2), full-10Mbps(3), half-100Mbps(4), full-100Mbps(5), half-1Gigabps(6), full-1Gigabps(7)  

swPortInfoFlowCtrlStatus 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.1.1.6
This object indicates the port flow control status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), flowctrl-disabled(2), flowctrl-enabled(3), backpressure-disabled(4), backpressure-enabled(5)  

swPortCtrlTable 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2
A table that contains control information about every port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwPortCtrlEntry

swPortCtrlEntry 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1
A list of control information for each port of the device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwPortCtrlEntry  

swPortCtrlModuleIndex 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.1
This object indicates the device module number.(1..Max module number)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swPortCtrlPortIndex 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.2
This object indicates the module's port number.(1..Max port number in the module)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swPortCtrlAdminState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.3
This object decide the port enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swPortCtrlLinkStatusAlarmState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.4
Depending on this object to determine to send a trap or not when link status changes .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swPortCtrlNwayState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.5
Chose the port speed, duplex mode, and N-Way function mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), nway-enabled(2), nway-disabled-10Mbps-Half(3), nway-disabled-10Mbps-Full(4), nway-disabled-100Mbps-Half(5), nway-disabled-100Mbps-Full(6), nway-disabled-1Gigabps-Half(7), nway-disabled-1Gigabps-Full(8)  

swPortCtrlFlowCtrlState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.6
Set IEEE 802.3x compliant flow control function as enabled or disabled. And IEEE 802.3x compliant flow control function work only when the port is in full duplex mode.If the port is set Auto-negotiation enabled, the object stands for flow control capability. The results should be referred to swPortInfoFlowCtrlStatus object. If the port is in force mode, this objects is simply used to set the flow control state (on/off). In force mode, if you change it from enabled to disabled state, it will work after next system restart. But the flow control changing from disabled to enabled state, it will immediately work.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swPortCtrlBackPressState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.7
Depending on this object determine to enable or disable the backpressure function when the port is working in half duplex mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swPortCtrlLockState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.8
The state of this entry. When the swDevCtrlTableLockState object is enabled, the state is not changed. When swVlanInfoStatus is in MAC-Base VLAN mode, this object is always disabled. The meanings of the values are: other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. disable(2) - Port lock funtion disable. enable(3) - Locking a port. Once the port is locked, it will not learn new SA addresses, and drop unknown/moved-SA packets forwarding to/from such ports. This is a way to prevent undesired traffic from being received or transmmited on the port. Note that locking a port doesn't lock the MAC address entries associated with the locked port, i.e. the existing address entries of the locked port will be age out even though it is locked.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disable(2), enable(3)  

swPortCtrlPriority 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.9
The priority queueing for packets received on this port, except for BPDU/IGMP packets and packets with unknown unicast destination address. IGMP and BPDU packets are always routed with high priority; packets with unknown unicast destination addresses are always routed with low priority. Other packets follow the rules below: other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. default(2) - A packet is normally classified as low priority ,unless at least one of the following is true: .The packet contained a TAG (per 802.1Q definition) with the priority greater or equal to 4. .The address-table entry for the destination address had Pd=HIGH. force-low_priority(3) - A packet is normally classified as low priority. force-high_priority(4) - A packet is normally classified as high priority.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), default(2), force-low-priority(3), force-high-priority(4)  

swPortCtrlStpState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.10
The state of STP(spanning tree algorithm) operation on this port. That's meaning the port whether add in the STP. The value enabled(3) indicates that STP is enabled on this port, as long as swDevCtrlStpState is also enabled for this device. When disabled(2) but swDevCtrlStpState is still enabled for the device, STP is disabled on this port : any BPDU packets received will be discarded and no BPDU packets will be propagated from the port.When the device is in 802.1Q Vlan mode, this object will be enabled and cannot be disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swPortCtrlHOLState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.11
The object provides a way to prevent HOL (Head Of Line) blocking between ports. HOL protection may prevent forwarding a packet to a blocking port.The idea relies on the assumption that it is better to discard packets destined to blocking ports, then to let them consume more and more buffers in the input-port's Rx-counters because eventually these input ports may become totally blocked. The value enabled(3) indicates that HOL function is enabled on this port, as long as swDevCtrlHOLState is also enabled for this device. When disabled(2) but swDevCtrlHOLState is still enabled for the device, HOL function is disabled on this port. The meanings of the values are: other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. disabled(2) - HOL function disable. enabled(3) - HOL function enable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swPortCtrlBroadcastRisingThr 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.12
This allows the user to specify the broadcast packets per second. Broadcast traffic above this rate activates broadcast storm control (i.e. swPortCtrlBroadcastRisingAct) on the port. The default value is 500 broadcast packets per second. The setting must be bigger than the value in swPortCtrlBroadcastFallingThr.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1488000  

swPortCtrlBroadcastFallingThr 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.13
This allows the user to specify the broadcast packets per second. If broadcast traffic is below this rate and rising threshold condition has been met at least once before this falling threshold is met, the device will apply the action described in swPortCtrlBroadcastFallingAct. The default value 250. The setting must be fewer than the value in swPortCtrlBroadcastRisingThr.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1488000  

swPortCtrlBroadcastRisingAct 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.14
This object indicates the system action when broadcast storm rising threshold is met. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. do-nothing(2) - no action. blocking(3) - the port can discard any coming broadcast frame. blocking-trap(4) - the port can discard any coming broadcast frame. And the device can send a broadcast rising trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), do-nothing(2), blocking(3), blocking-trap(4)  

swPortCtrlBroadcastFallingAct 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.15
This object indicates the device action when broadcast storm falling threshold is met. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. do-nothing(2) - no action. forwarding(3) - the port has returned to normal operation mode. forwarding-trap(4) - the port has returned to normal operation mode. And the device can send a broadcast falling trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), do-nothing(2), forwarding(3), forwarding-trap(4)  

swPortCtrlCleanAllStatisticCounter 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.2.1.16
Setting this object will reset current device's all statistic counters.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

swPortStTable 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3
A list of port statistic Counter entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwPortStEntry

swPortStEntry 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1
This entry include all the port statistic Counter which support by the device, like Bytes received, Bytes Sent ...
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwPortStEntry  

swPortStModuleIndex 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.1
This object indicates the device module number.(1..Max module number)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swPortStPortIndex 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.2
This object indicates the module's port number.(1..Max port number in the module)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swPortStByteRx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.3
swDevCtrlCounterMode = 2(switched-frames):This counter is incre- mented once for every data octet of good packets(unicast + multi- cast + broadcast) received. swDevCtrlCounterMode = 3(all-frames):This counter is incremented once for every data octet of good packets(unicast + multicast + broadcast packets) and for local and dropped packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStByteTx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.4
This counter is incremented once for every data octet of a trans- mitted good packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFrameRx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.5
swDevCtrlCounterMode = 2(switched-frames):This counter is incre- mented once for every good packet(unicast + multicast + broadcast ) received. swDevCtrlCounterMode = 3(all-frames):This counter is incremented once for every good packet(unicast + multicast + broadcast packets) and for local and dropped packets received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFrameTx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.6
This counter is incremented once for every transmitted good packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStTotalBytesRx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.7
This counter is incremented once for every data octet of all received packets. This include data octets of rejected and local packets which are not forwarded to the switching core for trans- mission. This counter should reflect all the data octets received on the line. Note: A nibble is not counted as a whole byte.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStTotalFramesRx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.8
This counter is incremented once for every received packets. This include rejected and local packets which are not forwarded to the switching core for transmission. This counter should reflect all packets received on the line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStBroadcastFramesRx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.9
swDevCtrlCounterMode = 2(switched-frames):This counter is incre- mented once for every good broadcast packet received. swDevCtrlCounterMode = 3(all-frames):This counter is incremented once for every good broadcast packet received and for local and dropped broadcast packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStMulticastFramesRx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.10
swDevCtrlCounterMode = 2(switched-frames):This counter is incre- mented once for every good multicast packet received. swDevCtrlCounterMode = 3(all-frames):This counter is incremented once for every good multicast packet received and for local and dropped multicast packets. This counter does not include broad- cast packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStCRCError 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.11
This counter is incremented once for every received packet which meets all the following conditions: 1.Packet data length is between 64 and 1518 bytes inclusive. 2.Packet has invalid CRC. 3.Collision event , late collision event and receive error event have not been detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStOversizeFrames 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.12
The number of good frames with length more than 1518 bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFragments 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.13
This counter is incremented once for every received packet which meets all the following conditions: 1.Packet data length is less than 64 bytes or packet withourt SFD and is less than 64 bytes in length. 2.Packet has invalid CRC. 3.Collision event , late collision event and receive error event have not been detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStJabber 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.14
The number of frames with length more than 1518 bytes and with CRC error or misaligned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStCollision 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.15
The number of Collisions
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStLateCollision 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.16
The number of Late Collision(collision occurring later than 576th transmitted bit).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFrames-64-bytes 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.17
This counter is incremented once for every received and trans- mitted packet with size of 64 bytes. This counter includes reject- ed received and transmitted packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFrames-65-127-bytes 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.18
This counter is incremented once for every received and trans- mitted packet with size of 65 to 127 bytes. This counter includes rejected received and transmitted packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFrames-128-255-bytes 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.19
This counter is incremented once for every received and trans- mitted packet with size of 128 to 255 bytes. This counter includes rejected received and transmitted packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFrames-256-511-bytes 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.20
This counter is incremented once for every received and trans- mitted packet with size of 256 to 511 bytes. This counter includes rejected received and transmitted packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFrames-512-1023-bytes 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.21
This counter is incremented once for every received and trans- mitted packet with size of 512 to 1023 bytes. This counter includ- es rejected received and transmitted packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFrames-1024-1536-bytes 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.22
This counter is incremented once for every received and trans- mitted packet with size of 1024 to 1536 bytes. This counter includ- es rejected received and transmitted packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStFramesDroppedFrames 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.23
This counter is incremented once for every received dropped pack- et.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStMulticastFramesTx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.24
The number of multicast frames sent. This counter does not include broadcast packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStBroadcastFramesTx 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.25
The number of broadcast frames sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swPortStUndersizeFrames 1.3.6.1.4.1.326.2.20.1.2.2.2.24.3.3.1.26
This counter is incremented once for every received packet which meets all the following conditions: 1.Packet data length is less than 64 bytes. 2.Packet has valid CRC. 3.Collision event , late collision event and receive error event have not been detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

swFdbStaticTable 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.1
Like typical legacy bridge devices, FDB table records the mapping of Source MAC Address and its associated source port, and forward incoming packets to its destination port according to the Destination MAC Address of the packet as well as the MAC-port pair entries of the FDB table. Note that the priority of FDB table entries is lower than Filtering Table, i.e. if there is a table hash collision between the entries of FDB Table and Filtering Table inside the switch H/W address table, then Filtering Table entry overwrite the colliding entry of FDB Table. See swFdbFilterTable description also.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwFdbStaticEntry

swFdbStaticEntry 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.1.1
A list of information specifies which ports the frames with specific destination MAC address to go.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwFdbStaticEntry  

swFdbStaticVid 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.1.1.1
This object indicates the VLAN-ID. If VLAN is in mac-based mode or disabled, the object indicates the default VLAN-ID (0).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swFdbStaticAddressIndex 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.1.1.2
The destination MAC address in a frame to which this entry's forwarding information applies. This object can take the value of an unicast address or the multicast address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

swFdbStaticPortMap 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.1.1.3
The set of ports to which frames received from a specific port and destined for a specific MAC address, are allowed to be forwarded. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the bridge is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'.(Note that the setting of the bit corresponding to the port from which a frame is received is irrelevant.). In module 1 (base module), there are 22 100M twisted-pair ports (port 1..22) which is mapped to the PortMap's port 1 to 22 respectively. In module 2 (slot 1 module), there are 2 100M FX/100 TX (or a single port 100M FX) ports which is mapped to the PortMap's port 23, 24 respectively (if the module is a single port 100M FX , it is just mapped to port 23 and port 24 is ignored). Module 3 (slot 2 module) is a single-port Gigabit Ethernet and it is mapped to the PortMap's port 25.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..4)  

swFdbStaticState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.1.1.4
This object indicates the status of this entry. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. invalid(2) - writing this value to the object, and then the corresponding entry will be removed from the table. valid(3) - this entry is reside in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), invalid(2), valid(3)  

swFdbStaticStatus 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.1.1.5
This object indicates the status of this entry. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. apply(2) - this entry is currently in use and reside in the table. not-apply(3) - this entry is reside in the table but currently not in use due to conflict with filter table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), apply(2), not-apply(3)  

swFdbFilterTable 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.2
A table which contains the filtering information of the unicast/multicast entries. This table is used by the transparent switching function in determining how to filter the received frames. The Filtering Table entries' priority overrides Static FDB Table as well as IGMP table entries, say, if there is a hash table entry collision between Filtering Table and Static FDB Table setting in the switch device's H/W address table, then Filter Table entry setting overwrites the colliding entry in Static FDB Table. See swFdbStaticTable description also.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwFdbFilterEntry

swFdbFilterEntry 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.2.1
A list of information about a specific unicast/multicast MAC address for which the switch has filtering information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SwFdbFilterEntry  

swFdbFilterVid 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.2.1.1
This object indicates the VLAN-ID.If VLAN is in mac-based mode or disabled, the object indicates the default VLAN-ID (0).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

swFdbFilterAddressIndex 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.2.1.2
This object indicates a unicast/multicast MAC address for which the bridge has filtering information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

swFdbFilterState 1.3.6.1.4.1.326.2.20.1.2.2.2.24.4.2.1.3
This object indicates the status of this entry. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. dst-src-addr(2) - recieved frames's destination address or source address are currently used to be filtered as it meets with the MAC address entry of the table. invalid(3) - writing this value to the object, and then the corresponding entry will be removed from the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), dst-src-addr(2), invalid(3)  

portPartition 1
The trap is sent whenever the port state enter the Partion mode when more than 61 collisions occur while trasmitting.
TRAP-TYPE    

linkChangeEvent 2
The trap is sent whenever the link state of a port changes from link up to link down or from link down to link up
TRAP-TYPE    

broadcastRisingStorm 3
The trap indicates that broadcast higher rising threshold . This trap including the port ID
TRAP-TYPE    

broadcastFallingStorm 4
The trap indicates that broadcast higher falling threshold . This trap including the port ID
TRAP-TYPE    

addressTableFull 5
The trap is sent whenever the address table is full .
TRAP-TYPE