ERI-DNX-PERF-MONT-MIB
File:
ERI-DNX-PERF-MONT-MIB.mib (24674 bytes)
Imported modules
Imported symbols
Defined Types
DSx1EsfCurrEntry |
|
SEQUENCE |
|
|
|
|
dsx1EsfCurrLinkAddr |
LinkPortAddress |
|
|
dsx1EsfCurrResrcId |
Integer32 |
|
|
dsx1EsfCurrESs |
Gauge32 |
|
|
dsx1EsfCurrUASs |
Gauge32 |
|
|
dsx1EsfCurrSESs |
Gauge32 |
|
|
dsx1EsfCurrBESs |
Gauge32 |
|
|
dsx1EsfCurrLOFs |
Gauge32 |
|
|
dsx1EsfCurrSeconds |
Gauge32 |
|
|
dsx1EsfCurrIntervals |
Gauge32 |
|
|
dsx1EsfCurrStatus |
DisplayString |
|
DSx1Esf24HrEntry |
|
SEQUENCE |
|
|
|
|
dsx1Esf24HrLinkAddr |
LinkPortAddress |
|
|
dsx1Esf24HrResrcId |
Integer32 |
|
|
dsx1Esf24HrESs |
Gauge32 |
|
|
dsx1Esf24HrUASs |
Gauge32 |
|
|
dsx1Esf24HrSESs |
Gauge32 |
|
|
dsx1Esf24HrBESs |
Gauge32 |
|
|
dsx1Esf24HrLOFs |
Gauge32 |
|
DSx1Esf96RegEntry |
|
SEQUENCE |
|
|
|
|
dsx1Esf96RegLinkAddr |
LinkPortAddress |
|
|
dsx1Esf96RegInterval |
Integer32 |
|
|
dsx1Esf96RegESs |
Gauge32 |
|
|
dsx1Esf96RegUASs |
Gauge32 |
|
|
dsx1Esf96RegSESs |
Gauge32 |
|
|
dsx1Esf96RegBESs |
Gauge32 |
|
DSx1G826Entry |
|
SEQUENCE |
|
|
|
|
dsx1G826LinkAddr |
LinkPortAddress |
|
|
dsx1G826ResrcId |
Integer32 |
|
|
dsx1G826TotalTime |
Integer32 |
|
|
dsx1G826ESs |
Gauge32 |
|
|
dsx1G826ErrFSs |
Gauge32 |
|
|
dsx1G826SESs |
Gauge32 |
|
|
dsx1G826ConsecSESs |
Gauge32 |
|
|
dsx1G826ConsecErrFSs |
Gauge32 |
|
|
dsx1G826BGErrBlocks |
Gauge32 |
|
|
dsx1G826ESRatio |
DisplayString |
|
|
dsx1G826SESRatio |
DisplayString |
|
|
dsx1G826BgBERRatio |
DisplayString |
|
|
dsx1G826UASs |
Gauge32 |
|
Defined Values
eriDNXLinkPMStatsMIB |
1.3.6.1.4.1.644.3.7 |
The ERI Enterprise MIB Module for the DNX DSx1 Performance Monitoring. |
MODULE-IDENTITY |
|
|
|
dsx1Esf |
1.3.6.1.4.1.644.2.4.4.1 |
OBJECT IDENTIFIER |
|
|
|
dsx1G826 |
1.3.6.1.4.1.644.2.4.4.2 |
OBJECT IDENTIFIER |
|
|
|
dsx1EsfCurrTable |
1.3.6.1.4.1.644.2.4.4.1.1 |
This is the DS1/E1 ESF Current Statistics table which consists
of an entry for each DS1 link in the system that is configured
for T1 ESF lines. This table provides the counters for the current
15 minute time interval. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
DSx1EsfCurrEntry |
|
dsx1EsfCurrEntry |
1.3.6.1.4.1.644.2.4.4.1.1.1 |
The conceptual row of the DS1/E1 ESF Statistics table.
A row in this table cannot be added, deleted, or modified
directly. Rows may be removed or added by configuring the
DS1 line type via the appropriate Device Provisioning table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DSx1EsfCurrEntry |
|
|
dsx1EsfCurrLinkAddr |
1.3.6.1.4.1.644.2.4.4.1.1.1.1 |
This number uniquely identifies an DS1/E1 link resource.
This number will be used throughout the system to identify
a unique link. The format is represented using an IP address
syntax (4 byte string). Note that the maximum valid link
number will vary depending on the specified carrier and framing
options. For example, an octal T1/E1 device has 8 DS1 links
however the DS3 has 28 DS1 links.
The 1st byte is reserved for future Nest Number use
The 2nd byte represents the Slot Number (1-11)
The 3rd byte represents the Link Number (1-84)
The 4th byte is reserved for future use
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
LinkPortAddress |
|
|
dsx1EsfCurrResrcId |
1.3.6.1.4.1.644.2.4.4.1.1.1.2 |
Uniquely identifies a link in the system.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
dsx1EsfCurrESs |
1.3.6.1.4.1.644.2.4.4.1.1.1.3 |
This is the number of errored seconds that have
occurred on the link during the current interval.
This is not incremented during an Unavailable Second.
For ESF links an Errored Second is a second with the
occurrence of a Loss of Frame or a CRC6 error in a
one-second period. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1EsfCurrUASs |
1.3.6.1.4.1.644.2.4.4.1.1.1.4 |
This is the number of failed seconds (UAS) that have
occurred on the link during the current interval.
Unavailable Seconds (UAS) are calculated by counting the number
of seconds that the interface is unavailable. Each second period
during the occurrence of a Failed Signal State (ten consecutive SES)
is known as a failed/unavailable second. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1EsfCurrSESs |
1.3.6.1.4.1.644.2.4.4.1.1.1.5 |
This is the number of severely errored seconds that have
occurred on the link during the current interval. Controlled
slips are not included in this parameter. This is not incremented
during an Unavailable Second.
A Severely Errored Second for ESF signals is a second period with
320 or more CRC6 errors. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1EsfCurrBESs |
1.3.6.1.4.1.644.2.4.4.1.1.1.6 |
This is the number of bursty errored seconds that have
occurred on the T1 link during the current interval.
This is not incremented during an Unavailable Second and
applies to ESF signals only.
A Bursty Errored Second is a second period with more than one
but less than 320 CRC6 errors. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1EsfCurrLOFs |
1.3.6.1.4.1.644.2.4.4.1.1.1.7 |
This is the number of loss of frames that have
occurred on the link during the current interval.
A loss of frame occurs when either network equipment or the
DTE senses errors in the framing pattern. Depending upon the
equipment, this occurs when any 2 of 4, 2 of 5, or 3 of 5
consecutive terminal framing bits received contain bit errors
in the framing pattern. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1EsfCurrSeconds |
1.3.6.1.4.1.644.2.4.4.1.1.1.8 |
The total number of seconds in the current interval. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1EsfCurrIntervals |
1.3.6.1.4.1.644.2.4.4.1.1.1.9 |
The total number of valid 15 minute intervals counted since
the link has been up and running. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..96 |
|
dsx1EsfCurrStatus |
1.3.6.1.4.1.644.2.4.4.1.1.1.10 |
This defines the status of the DS1/E1 link using an 8 character
code which can contain numbers or letters. The codes are
interpreted as follows:
character #1 - 'F' or zero where 'F' indicates Failed Signal
Status (FSS) if 'U' or 'L' are present.
character #2 - 'U' or zero where 'U' indicates an
unavailable signal state.
character #3 through #6 are always zero.
character #7 - 'L' or zero where 'L' indicates that the T1
line is in loop.
character #8 - always zero. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(8) |
|
dsx1Esf24HrTable |
1.3.6.1.4.1.644.2.4.4.1.2 |
This is the DS1/E1 24 Hour ESF Statistics table which consists
of an entry for each DS1/E1 link in the system that is configured
for T1 ESF lines. This table provides the total counters accumulated
for last 24 hour period. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
DSx1Esf24HrEntry |
|
dsx1Esf24HrEntry |
1.3.6.1.4.1.644.2.4.4.1.2.1 |
The conceptual row of the DS1/E1 24 Hour ESF Statistics table.
A row in this table cannot be added, deleted, or modified
directly. Rows may be removed or added by configuring the
DS1 line type via the appropriate Device Provisioning table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DSx1Esf24HrEntry |
|
|
dsx1Esf24HrLinkAddr |
1.3.6.1.4.1.644.2.4.4.1.2.1.1 |
This number uniquely identifies an DS1/E1 link resource.
This number will be used throughout the system to identify
a unique link. The format is represented using an IP address
syntax (4 byte string). Note that the maximum valid link
number will vary depending on the specified carrier and framing
options. For example, an octal T1/E1 device has 8 DS1 links but the
DS3 has 28 DS1 links.
The 1st byte is reserved for future Nest Number use
The 2nd byte represents the Slot Number (1-11)
The 3rd byte represents the Link Number (1-84)
The 4th byte is reserved for future use
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
LinkPortAddress |
|
|
dsx1Esf24HrResrcId |
1.3.6.1.4.1.644.2.4.4.1.2.1.2 |
Uniquely identifies a link in the system.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
dsx1Esf24HrESs |
1.3.6.1.4.1.644.2.4.4.1.2.1.3 |
This is the number of errored seconds that have
occurred on the link during the past 24 hours. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..65535 |
|
dsx1Esf24HrUASs |
1.3.6.1.4.1.644.2.4.4.1.2.1.4 |
This is the number of Unavailable Seconds (UAS) that
have occurred on the T1 link during the past 24 hours. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..65535 |
|
dsx1Esf24HrSESs |
1.3.6.1.4.1.644.2.4.4.1.2.1.5 |
This is the number of severely errored seconds that have
occurred on the T1 link during the past 24 hours. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..65535 |
|
dsx1Esf24HrBESs |
1.3.6.1.4.1.644.2.4.4.1.2.1.6 |
This is the number of bursty errored seconds that have
occurred on the T1 link during the past 24 hours. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..65535 |
|
dsx1Esf24HrLOFs |
1.3.6.1.4.1.644.2.4.4.1.2.1.7 |
This is the number of loss of frames that have
occurred on the T1 link during the past 24 hours. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..65535 |
|
dsx1Esf96RegTable |
1.3.6.1.4.1.644.2.4.4.1.3 |
This table is the ESF 96 Registers Table. It displays the 96
15 minute performance registers for each link on a card |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
DSx1Esf96RegEntry |
|
dsx1Esf96RegEntry |
1.3.6.1.4.1.644.2.4.4.1.3.1 |
The conceptual row of the DS1/E1 ESF 96 Registers table.
A row in this table cannot be added, deleted, or modified
directly. Rows may be removed or added by configuring the
DS1 line type via the appropriate Device Provisioning table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DSx1Esf96RegEntry |
|
|
dsx1Esf96RegLinkAddr |
1.3.6.1.4.1.644.2.4.4.1.3.1.1 |
Uniquely identifies a link in the system.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
LinkPortAddress |
|
|
dsx1Esf96RegInterval |
1.3.6.1.4.1.644.2.4.4.1.3.1.2 |
Specifies the interval Number On a particular link |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..96 |
|
dsx1Esf96RegESs |
1.3.6.1.4.1.644.2.4.4.1.3.1.3 |
The number of Errored Seconds for a particular interval
on a particular link |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1Esf96RegUASs |
1.3.6.1.4.1.644.2.4.4.1.3.1.4 |
The number of Unavailable Seconds for a particular interval
on a particular link |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1Esf96RegSESs |
1.3.6.1.4.1.644.2.4.4.1.3.1.5 |
The number of Severely Errored Seconds for a particular interval
on a particular link |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1Esf96RegBESs |
1.3.6.1.4.1.644.2.4.4.1.3.1.6 |
The number of Bursty Errored Seconds for a particular interval
on a particular link |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..900 |
|
dsx1G826Table |
1.3.6.1.4.1.644.2.4.4.2.1 |
This is the DS1/E1 G.826 Statistics table which consists
of an entry for each DS1/E1 link in the system. This table
provides the total counters accumulated since the link has
been up or since the last time the counts were cleared. The
counters are calculated in accordance with the ITU-T G.826
Error performance parameters, November 1993. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
DSx1G826Entry |
|
dsx1G826Entry |
1.3.6.1.4.1.644.2.4.4.2.1.1 |
The conceptual row of the DS1/E1 G.826 Statistics table.
A row in this table cannot be added or deleted directly but
the counter time period can be reset to zero. Rows may be
removed or added by configuring the DS1/E1 line type via the
appropriate Device Provisioning tables. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DSx1G826Entry |
|
|
dsx1G826LinkAddr |
1.3.6.1.4.1.644.2.4.4.2.1.1.1 |
This number uniquely identifies an DS1/E1 link resource.
This number will be used throughout the system to identify
a unique link. The format is represented using an IP address
syntax (4 byte string). Note that the maximum valid link
number will vary depending on the specified carrier and framing
options. For example, an octal T1/E1 device has 8 DS1 links but the
DS3 has 28 DS1 links.
The 1st byte is reserved for future Nest Number use
The 2nd byte represents the Slot Number (1-11)
The 3rd byte represents the Link Number (1-84)
The 4th byte is reserved for future use
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
LinkPortAddress |
|
|
dsx1G826ResrcId |
1.3.6.1.4.1.644.2.4.4.2.1.1.2 |
Uniquely identifies a link in the system.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
dsx1G826TotalTime |
1.3.6.1.4.1.644.2.4.4.2.1.1.3 |
This the total number of seconds the G.826 data has been collected.
Resetting this to zero will clear the counters for specific link. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
dsx1G826ESs |
1.3.6.1.4.1.644.2.4.4.2.1.1.4 |
This is the total number of errored seconds that have
occurred since the link has been up or since the G.826
counters have been reset.
An Errored Second for G.826 is a one second period with one
or more errored blocks or at least one defect. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
dsx1G826ErrFSs |
1.3.6.1.4.1.644.2.4.4.2.1.1.5 |
This is the total number of error free seconds since the
link has been up or since the G.826 counters have been reset. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
dsx1G826SESs |
1.3.6.1.4.1.644.2.4.4.2.1.1.6 |
This is the total number of severely errored seconds that have
occurred since the link has been up or since the G.826 counters
have been reset.
A Severely Errored Second for G.826 is a one second period that
contains 30% or more errored blocks OR at least one defect.
This is a subset of ES. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
dsx1G826ConsecSESs |
1.3.6.1.4.1.644.2.4.4.2.1.1.7 |
This is the total number of continuous occurrences of SES,
in a one second intervals, since the link has been up
or since the G.826 counters have been reset. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
dsx1G826ConsecErrFSs |
1.3.6.1.4.1.644.2.4.4.2.1.1.8 |
This is the total number of consecutive seconds one second
period intervals that did not have defects or errors since
the link has been up or since the G.826 counters have been reset. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
dsx1G826BGErrBlocks |
1.3.6.1.4.1.644.2.4.4.2.1.1.9 |
This is the total number of background errored blocks that have
occurred since the link has been up or since the G.826 counters
have been reset.
A Background Block Error for G.826 is an errored block not
occurring as part of an SES. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
dsx1G826ESRatio |
1.3.6.1.4.1.644.2.4.4.2.1.1.10 |
This is the ratio of ES to total seconds in available time
during a fixed measurement interval rounded to 2 decimals. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
dsx1G826SESRatio |
1.3.6.1.4.1.644.2.4.4.2.1.1.11 |
This is the ratio of SES to total seconds in available time
during a fixed measurement interval rounded to 2 decimals. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
dsx1G826BgBERRatio |
1.3.6.1.4.1.644.2.4.4.2.1.1.12 |
This is the ratio of background block errors to total blocks
in available time during a fixed measurement interval rounded
to 2 decimals. This total block count excludes all blocks
during SES. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
dsx1G826UASs |
1.3.6.1.4.1.644.2.4.4.2.1.1.13 |
This is the total number of Unavailable Seconds (UAS) that have
occurred since the link has been up or since the G.826 counters
have been reset. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|