ERI-DNX-PERF-MONT-MIB

File: ERI-DNX-PERF-MONT-MIB.mib (24674 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC ERI-ROOT-SMI
ERI-DNX-SMC-MIB

Imported symbols

MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
Integer32 Gauge32 DisplayString
eriMibs LinkPortAddress dnx

Defined Types

DSx1EsfCurrEntry  
SEQUENCE    
  dsx1EsfCurrLinkAddr LinkPortAddress
  dsx1EsfCurrResrcId Integer32
  dsx1EsfCurrESs Gauge32
  dsx1EsfCurrUASs Gauge32
  dsx1EsfCurrSESs Gauge32
  dsx1EsfCurrBESs Gauge32
  dsx1EsfCurrLOFs Gauge32
  dsx1EsfCurrSeconds Gauge32
  dsx1EsfCurrIntervals Gauge32
  dsx1EsfCurrStatus DisplayString

DSx1Esf24HrEntry  
SEQUENCE    
  dsx1Esf24HrLinkAddr LinkPortAddress
  dsx1Esf24HrResrcId Integer32
  dsx1Esf24HrESs Gauge32
  dsx1Esf24HrUASs Gauge32
  dsx1Esf24HrSESs Gauge32
  dsx1Esf24HrBESs Gauge32
  dsx1Esf24HrLOFs Gauge32

DSx1Esf96RegEntry  
SEQUENCE    
  dsx1Esf96RegLinkAddr LinkPortAddress
  dsx1Esf96RegInterval Integer32
  dsx1Esf96RegESs Gauge32
  dsx1Esf96RegUASs Gauge32
  dsx1Esf96RegSESs Gauge32
  dsx1Esf96RegBESs Gauge32

DSx1G826Entry  
SEQUENCE    
  dsx1G826LinkAddr LinkPortAddress
  dsx1G826ResrcId Integer32
  dsx1G826TotalTime Integer32
  dsx1G826ESs Gauge32
  dsx1G826ErrFSs Gauge32
  dsx1G826SESs Gauge32
  dsx1G826ConsecSESs Gauge32
  dsx1G826ConsecErrFSs Gauge32
  dsx1G826BGErrBlocks Gauge32
  dsx1G826ESRatio DisplayString
  dsx1G826SESRatio DisplayString
  dsx1G826BgBERRatio DisplayString
  dsx1G826UASs Gauge32

Defined Values

eriDNXLinkPMStatsMIB 1.3.6.1.4.1.644.3.7
The ERI Enterprise MIB Module for the DNX DSx1 Performance Monitoring.
MODULE-IDENTITY    

performanceMonitoring 1.3.6.1.4.1.644.2.4.4
OBJECT IDENTIFIER    

dsx1Esf 1.3.6.1.4.1.644.2.4.4.1
OBJECT IDENTIFIER    

dsx1G826 1.3.6.1.4.1.644.2.4.4.2
OBJECT IDENTIFIER    

dsx1EsfCurrTable 1.3.6.1.4.1.644.2.4.4.1.1
This is the DS1/E1 ESF Current Statistics table which consists of an entry for each DS1 link in the system that is configured for T1 ESF lines. This table provides the counters for the current 15 minute time interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DSx1EsfCurrEntry

dsx1EsfCurrEntry 1.3.6.1.4.1.644.2.4.4.1.1.1
The conceptual row of the DS1/E1 ESF Statistics table. A row in this table cannot be added, deleted, or modified directly. Rows may be removed or added by configuring the DS1 line type via the appropriate Device Provisioning table.
Status: current Access: not-accessible
OBJECT-TYPE    
  DSx1EsfCurrEntry  

dsx1EsfCurrLinkAddr 1.3.6.1.4.1.644.2.4.4.1.1.1.1
This number uniquely identifies an DS1/E1 link resource. This number will be used throughout the system to identify a unique link. The format is represented using an IP address syntax (4 byte string). Note that the maximum valid link number will vary depending on the specified carrier and framing options. For example, an octal T1/E1 device has 8 DS1 links however the DS3 has 28 DS1 links. The 1st byte is reserved for future Nest Number use The 2nd byte represents the Slot Number (1-11) The 3rd byte represents the Link Number (1-84) The 4th byte is reserved for future use
Status: current Access: read-only
OBJECT-TYPE    
  LinkPortAddress  

dsx1EsfCurrResrcId 1.3.6.1.4.1.644.2.4.4.1.1.1.2
Uniquely identifies a link in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dsx1EsfCurrESs 1.3.6.1.4.1.644.2.4.4.1.1.1.3
This is the number of errored seconds that have occurred on the link during the current interval. This is not incremented during an Unavailable Second. For ESF links an Errored Second is a second with the occurrence of a Loss of Frame or a CRC6 error in a one-second period.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1EsfCurrUASs 1.3.6.1.4.1.644.2.4.4.1.1.1.4
This is the number of failed seconds (UAS) that have occurred on the link during the current interval. Unavailable Seconds (UAS) are calculated by counting the number of seconds that the interface is unavailable. Each second period during the occurrence of a Failed Signal State (ten consecutive SES) is known as a failed/unavailable second.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1EsfCurrSESs 1.3.6.1.4.1.644.2.4.4.1.1.1.5
This is the number of severely errored seconds that have occurred on the link during the current interval. Controlled slips are not included in this parameter. This is not incremented during an Unavailable Second. A Severely Errored Second for ESF signals is a second period with 320 or more CRC6 errors.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1EsfCurrBESs 1.3.6.1.4.1.644.2.4.4.1.1.1.6
This is the number of bursty errored seconds that have occurred on the T1 link during the current interval. This is not incremented during an Unavailable Second and applies to ESF signals only. A Bursty Errored Second is a second period with more than one but less than 320 CRC6 errors.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1EsfCurrLOFs 1.3.6.1.4.1.644.2.4.4.1.1.1.7
This is the number of loss of frames that have occurred on the link during the current interval. A loss of frame occurs when either network equipment or the DTE senses errors in the framing pattern. Depending upon the equipment, this occurs when any 2 of 4, 2 of 5, or 3 of 5 consecutive terminal framing bits received contain bit errors in the framing pattern.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1EsfCurrSeconds 1.3.6.1.4.1.644.2.4.4.1.1.1.8
The total number of seconds in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1EsfCurrIntervals 1.3.6.1.4.1.644.2.4.4.1.1.1.9
The total number of valid 15 minute intervals counted since the link has been up and running.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..96  

dsx1EsfCurrStatus 1.3.6.1.4.1.644.2.4.4.1.1.1.10
This defines the status of the DS1/E1 link using an 8 character code which can contain numbers or letters. The codes are interpreted as follows: character #1 - 'F' or zero where 'F' indicates Failed Signal Status (FSS) if 'U' or 'L' are present. character #2 - 'U' or zero where 'U' indicates an unavailable signal state. character #3 through #6 are always zero. character #7 - 'L' or zero where 'L' indicates that the T1 line is in loop. character #8 - always zero.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

dsx1Esf24HrTable 1.3.6.1.4.1.644.2.4.4.1.2
This is the DS1/E1 24 Hour ESF Statistics table which consists of an entry for each DS1/E1 link in the system that is configured for T1 ESF lines. This table provides the total counters accumulated for last 24 hour period.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DSx1Esf24HrEntry

dsx1Esf24HrEntry 1.3.6.1.4.1.644.2.4.4.1.2.1
The conceptual row of the DS1/E1 24 Hour ESF Statistics table. A row in this table cannot be added, deleted, or modified directly. Rows may be removed or added by configuring the DS1 line type via the appropriate Device Provisioning table.
Status: current Access: not-accessible
OBJECT-TYPE    
  DSx1Esf24HrEntry  

dsx1Esf24HrLinkAddr 1.3.6.1.4.1.644.2.4.4.1.2.1.1
This number uniquely identifies an DS1/E1 link resource. This number will be used throughout the system to identify a unique link. The format is represented using an IP address syntax (4 byte string). Note that the maximum valid link number will vary depending on the specified carrier and framing options. For example, an octal T1/E1 device has 8 DS1 links but the DS3 has 28 DS1 links. The 1st byte is reserved for future Nest Number use The 2nd byte represents the Slot Number (1-11) The 3rd byte represents the Link Number (1-84) The 4th byte is reserved for future use
Status: current Access: read-only
OBJECT-TYPE    
  LinkPortAddress  

dsx1Esf24HrResrcId 1.3.6.1.4.1.644.2.4.4.1.2.1.2
Uniquely identifies a link in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dsx1Esf24HrESs 1.3.6.1.4.1.644.2.4.4.1.2.1.3
This is the number of errored seconds that have occurred on the link during the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..65535  

dsx1Esf24HrUASs 1.3.6.1.4.1.644.2.4.4.1.2.1.4
This is the number of Unavailable Seconds (UAS) that have occurred on the T1 link during the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..65535  

dsx1Esf24HrSESs 1.3.6.1.4.1.644.2.4.4.1.2.1.5
This is the number of severely errored seconds that have occurred on the T1 link during the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..65535  

dsx1Esf24HrBESs 1.3.6.1.4.1.644.2.4.4.1.2.1.6
This is the number of bursty errored seconds that have occurred on the T1 link during the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..65535  

dsx1Esf24HrLOFs 1.3.6.1.4.1.644.2.4.4.1.2.1.7
This is the number of loss of frames that have occurred on the T1 link during the past 24 hours.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..65535  

dsx1Esf96RegTable 1.3.6.1.4.1.644.2.4.4.1.3
This table is the ESF 96 Registers Table. It displays the 96 15 minute performance registers for each link on a card
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DSx1Esf96RegEntry

dsx1Esf96RegEntry 1.3.6.1.4.1.644.2.4.4.1.3.1
The conceptual row of the DS1/E1 ESF 96 Registers table. A row in this table cannot be added, deleted, or modified directly. Rows may be removed or added by configuring the DS1 line type via the appropriate Device Provisioning table.
Status: current Access: not-accessible
OBJECT-TYPE    
  DSx1Esf96RegEntry  

dsx1Esf96RegLinkAddr 1.3.6.1.4.1.644.2.4.4.1.3.1.1
Uniquely identifies a link in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
Status: current Access: read-only
OBJECT-TYPE    
  LinkPortAddress  

dsx1Esf96RegInterval 1.3.6.1.4.1.644.2.4.4.1.3.1.2
Specifies the interval Number On a particular link
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

dsx1Esf96RegESs 1.3.6.1.4.1.644.2.4.4.1.3.1.3
The number of Errored Seconds for a particular interval on a particular link
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1Esf96RegUASs 1.3.6.1.4.1.644.2.4.4.1.3.1.4
The number of Unavailable Seconds for a particular interval on a particular link
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1Esf96RegSESs 1.3.6.1.4.1.644.2.4.4.1.3.1.5
The number of Severely Errored Seconds for a particular interval on a particular link
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1Esf96RegBESs 1.3.6.1.4.1.644.2.4.4.1.3.1.6
The number of Bursty Errored Seconds for a particular interval on a particular link
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

dsx1G826Table 1.3.6.1.4.1.644.2.4.4.2.1
This is the DS1/E1 G.826 Statistics table which consists of an entry for each DS1/E1 link in the system. This table provides the total counters accumulated since the link has been up or since the last time the counts were cleared. The counters are calculated in accordance with the ITU-T G.826 Error performance parameters, November 1993.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DSx1G826Entry

dsx1G826Entry 1.3.6.1.4.1.644.2.4.4.2.1.1
The conceptual row of the DS1/E1 G.826 Statistics table. A row in this table cannot be added or deleted directly but the counter time period can be reset to zero. Rows may be removed or added by configuring the DS1/E1 line type via the appropriate Device Provisioning tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  DSx1G826Entry  

dsx1G826LinkAddr 1.3.6.1.4.1.644.2.4.4.2.1.1.1
This number uniquely identifies an DS1/E1 link resource. This number will be used throughout the system to identify a unique link. The format is represented using an IP address syntax (4 byte string). Note that the maximum valid link number will vary depending on the specified carrier and framing options. For example, an octal T1/E1 device has 8 DS1 links but the DS3 has 28 DS1 links. The 1st byte is reserved for future Nest Number use The 2nd byte represents the Slot Number (1-11) The 3rd byte represents the Link Number (1-84) The 4th byte is reserved for future use
Status: current Access: read-only
OBJECT-TYPE    
  LinkPortAddress  

dsx1G826ResrcId 1.3.6.1.4.1.644.2.4.4.2.1.1.2
Uniquely identifies a link in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dsx1G826TotalTime 1.3.6.1.4.1.644.2.4.4.2.1.1.3
This the total number of seconds the G.826 data has been collected. Resetting this to zero will clear the counters for specific link.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

dsx1G826ESs 1.3.6.1.4.1.644.2.4.4.2.1.1.4
This is the total number of errored seconds that have occurred since the link has been up or since the G.826 counters have been reset. An Errored Second for G.826 is a one second period with one or more errored blocks or at least one defect.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dsx1G826ErrFSs 1.3.6.1.4.1.644.2.4.4.2.1.1.5
This is the total number of error free seconds since the link has been up or since the G.826 counters have been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dsx1G826SESs 1.3.6.1.4.1.644.2.4.4.2.1.1.6
This is the total number of severely errored seconds that have occurred since the link has been up or since the G.826 counters have been reset. A Severely Errored Second for G.826 is a one second period that contains 30% or more errored blocks OR at least one defect. This is a subset of ES.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dsx1G826ConsecSESs 1.3.6.1.4.1.644.2.4.4.2.1.1.7
This is the total number of continuous occurrences of SES, in a one second intervals, since the link has been up or since the G.826 counters have been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dsx1G826ConsecErrFSs 1.3.6.1.4.1.644.2.4.4.2.1.1.8
This is the total number of consecutive seconds one second period intervals that did not have defects or errors since the link has been up or since the G.826 counters have been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dsx1G826BGErrBlocks 1.3.6.1.4.1.644.2.4.4.2.1.1.9
This is the total number of background errored blocks that have occurred since the link has been up or since the G.826 counters have been reset. A Background Block Error for G.826 is an errored block not occurring as part of an SES.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dsx1G826ESRatio 1.3.6.1.4.1.644.2.4.4.2.1.1.10
This is the ratio of ES to total seconds in available time during a fixed measurement interval rounded to 2 decimals.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dsx1G826SESRatio 1.3.6.1.4.1.644.2.4.4.2.1.1.11
This is the ratio of SES to total seconds in available time during a fixed measurement interval rounded to 2 decimals.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dsx1G826BgBERRatio 1.3.6.1.4.1.644.2.4.4.2.1.1.12
This is the ratio of background block errors to total blocks in available time during a fixed measurement interval rounded to 2 decimals. This total block count excludes all blocks during SES.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dsx1G826UASs 1.3.6.1.4.1.644.2.4.4.2.1.1.13
This is the total number of Unavailable Seconds (UAS) that have occurred since the link has been up or since the G.826 counters have been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32