ENTERASYS-IEEE8021-Q-BRIDGE-MIB-EXT-MIB

File: ENTERASYS-IEEE8021-Q-BRIDGE-MIB-EXT-MIB.mib (15801 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
IEEE8021-TC-MIB P-BRIDGE-MIB IEEE8021-BRIDGE-MIB
ENTERASYS-MIB-NAMES

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter64
MODULE-COMPLIANCE OBJECT-GROUP TEXTUAL-CONVENTION
IEEE8021PbbComponentIdentifier IEEE8021VlanIndex EnabledStatus
ieee8021BridgeBasePortEntry etsysModules

Defined Types

EtsysIeee8021QBridgeFdbEntries  
Integer that especifies the maximum number of entries in the filter database.
TEXTUAL-CONVENTION    
  INTEGER is4K(4096), is8K(8192), is16K(16384), is32K(32768), is64K(65536), is128K(131072)  

EtsysIeee8021QVlanMvrpRestrictedEntry  
SEQUENCE    
  etsysIeee8021QVlanMvrpRestrictedComponentId IEEE8021PbbComponentIdentifier
  etsysIeee8021QVlanMvrpRestrictedIndex IEEE8021VlanIndex
  etsysIeee8021QVlanMvrpRestrictedStatus EnabledStatus

EtsysIeee8021QBridgeMibExtPortVlanEntry  
SEQUENCE    
  etsysIeee8021QBridgePortMvrpRxVidTranslationErrors Counter64
  etsysIeee8021QBridgePortMvrpTxVidTranslationErrors Counter64

Defined Values

etsysIeee8021QBridgeMibExtMIB 1.3.6.1.4.1.5624.1.2.88
This MIB module defines a portion of the SNMP MIB under the Enterasys Networks enterprise OID pertaining to proprietary extensions to the IEEE8021-Q-BRIDGE-MIB.
MODULE-IDENTITY    

etsysIeee8021QBridgeMibExtObjects 1.3.6.1.4.1.5624.1.2.88.1
OBJECT IDENTIFIER    

etsysIeee8021QBridgeMibExtConformance 1.3.6.1.4.1.5624.1.2.88.2
OBJECT IDENTIFIER    

etsysIeee8021QBridgeMibExtMvrpBranch 1.3.6.1.4.1.5624.1.2.88.1.1
OBJECT IDENTIFIER    

etsysIeee8021QBridgeMibExtPortVlanBranch 1.3.6.1.4.1.5624.1.2.88.1.2
OBJECT IDENTIFIER    

etsysIeee8021QBridgeMibExtFdbBranch 1.3.6.1.4.1.5624.1.2.88.1.3
OBJECT IDENTIFIER    

etsysIeee8021QVlanMvrpRestrictedTable 1.3.6.1.4.1.5624.1.2.88.1.1.1
A table containing per VLAN control and status information for MVRP VLAN configuration in the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EtsysIeee8021QVlanMvrpRestrictedEntry

etsysIeee8021QVlanMvrpRestrictedEntry 1.3.6.1.4.1.5624.1.2.88.1.1.1.1
Information controlling proprietary VLAN configuration for MVRP on a device.
Status: current Access: not-accessible
OBJECT-TYPE    
  EtsysIeee8021QVlanMvrpRestrictedEntry  

etsysIeee8021QVlanMvrpRestrictedComponentId 1.3.6.1.4.1.5624.1.2.88.1.1.1.1.1
The PBB component identifier to which this entry's restricted MVRP VLAN attribute status applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

etsysIeee8021QVlanMvrpRestrictedIndex 1.3.6.1.4.1.5624.1.2.88.1.1.1.1.2
The VLAN to which this entry's restricted MVRP VLAN attribute status applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021VlanIndex  

etsysIeee8021QVlanMvrpRestrictedStatus 1.3.6.1.4.1.5624.1.2.88.1.1.1.1.3
The state of restricted MVRP operation for this VLAN. The value enabled(1) indicates that restricted MVRP operation is enabled for this VLAN. This object affects MVRP Applicant and Registrar state machines for this VLAN on all ports. If restricted MVRP is enabled for a VLAN the following rules are applied: 1. If MVRP is globally enabled and 2. If MVRP is enabled at the port level, then 3. Any ports that were members of the dot1qVlanCurrentEgressPorts table due to MVRP will signal to remove this registration and no further registration requests received in MVRP PDUs for this VLAN will be processed and 4. Any ports that were propagating registration information for this VLAN will cease propagation and all further MVRP PDUs transmitted after the initial withdrawal attempt will not include event notifications for this VLAN.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

etsysIeee8021QBridgeMibExtPortVlanTable 1.3.6.1.4.1.5624.1.2.88.1.2.1
A table of bridge port MRP timer control information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EtsysIeee8021QBridgeMibExtPortVlanEntry

etsysIeee8021QBridgeMibExtPortVlanEntry 1.3.6.1.4.1.5624.1.2.88.1.2.1.1
A conceptual row in etsysIeee8021QBridgeMibExtPortVlanTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  EtsysIeee8021QBridgeMibExtPortVlanEntry  

etsysIeee8021QBridgePortMvrpRxVidTranslationErrors 1.3.6.1.4.1.5624.1.2.88.1.2.1.1.1
The total number of receive errors for MVRP due to an incompatible VID translation configuration on a port. This error occurs when an MVRPDU is received on a port which has a VID translation table configured and the MVRPDU contains messages for multiple local VIDs that map to the same relay VID. The MVRPDU is discarded when this error is detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

etsysIeee8021QBridgePortMvrpTxVidTranslationErrors 1.3.6.1.4.1.5624.1.2.88.1.2.1.1.2
The total number of transmit errors for MVRP due to an incompatible VID translation configuration on a port. This error occurs when an MVRPDU is being encoded for transmit on a port which has a VID translation table configured and the MVRPDU has messages for multiple local VIDs that map to the same relay VID. The MVRPDU is discarded when this error occurs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

etsysIeee8021QBridgeFdb 1.3.6.1.4.1.5624.1.2.88.1.3.1
OBJECT IDENTIFIER    

etsysIeee8021QBridgeFdbMaxNumEntriesCapabilities 1.3.6.1.4.1.5624.1.2.88.1.3.1.1
Indicates the values of maximum number of entries supported by the hardware. The possible values are as follows: fdbMaxNumEntries4K(0) - The maximum number of entries in the filter database is 4K (4096). fdbMaxNumEntries8K(1) - The maximum number of entries in the filter database is 8K (8192). fdbMaxNumEntries16K(2) - The maximum number of entries in the filter database is 16K (16384). fdbMaxNumEntries32K(3) - The maximum number of entries in the filter database is 32K (32768). fdbMaxNumEntries64K(4) - The maximum number of entries in the filter database is 64K (65536). fdbMaxNumEntries128K(5) - The maximum number of entries in the filter database is 128K (131072).
Status: current Access: read-only
OBJECT-TYPE    
  BITS fdbMaxNumEntries4K(0), fdbMaxNumEntries8K(1), fdbMaxNumEntries16K(2), fdbMaxNumEntries32K(3), fdbMaxNumEntries64K(4), fdbMaxNumEntries128K(5)  

etsysIeee8021QBridgeFdbMaxNumEntries 1.3.6.1.4.1.5624.1.2.88.1.3.1.2
Indicates the configured maximum number of entries in the filter database.
Status: current Access: read-write
OBJECT-TYPE    
  EtsysIeee8021QBridgeFdbEntries  

etsysIeee8021QBridgeFdbOperMaxNumEntries 1.3.6.1.4.1.5624.1.2.88.1.3.1.3
Indicates the operational maximum number of entries in the filter database.
Status: current Access: read-only
OBJECT-TYPE    
  EtsysIeee8021QBridgeFdbEntries  

etsysIeee8021QBridgeMibExtGroups 1.3.6.1.4.1.5624.1.2.88.2.1
OBJECT IDENTIFIER    

etsysIeee8021QBridgeMibExtCompliances 1.3.6.1.4.1.5624.1.2.88.2.2
OBJECT IDENTIFIER    

etsysIeee8021QBridgeMibExtMvrpGroup 1.3.6.1.4.1.5624.1.2.88.2.1.1
A collection of objects providing device level control over the ability of MVRP to add and remove unconfigured ports to the egress list of particular VLANs.
Status: current Access: read-only
OBJECT-GROUP    

etsysIeee8021QBridgeMibExtPortVlanGroup 1.3.6.1.4.1.5624.1.2.88.2.1.2
A collection of objects providing statistics on errors detected by MVRP that identify incompatible configuration of the VID translation table.
Status: current Access: read-only
OBJECT-GROUP    

etsysIeee8021QBridgeMibExtFdbGroup 1.3.6.1.4.1.5624.1.2.88.2.1.3
A collection of objects providing information about the maximum number of entries in the filter database.
Status: current Access: read-only
OBJECT-GROUP    

etsysIeee8021QBridgeMibExtMvrp 1.3.6.1.4.1.5624.1.2.88.2.2.1
The compliance statement for devices that support Enterasys extensions to IEEE8021-Q-BRIDGE-MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

etsysIeee8021QBridgeMibExtPortVlan 1.3.6.1.4.1.5624.1.2.88.2.2.2
The compliance statement for devices that support Enterasys extensions to IEEE8021-Q-BRIDGE-MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

etsysIeee8021QBridgeMibExtFdb 1.3.6.1.4.1.5624.1.2.88.2.2.3
The compliance statement for devices that support Enterasys extensions to IEEE8021-Q-BRIDGE-MIB.
Status: current Access: read-only
MODULE-COMPLIANCE