ENTERASYS-AUTO-TRACKING-MIB

File: ENTERASYS-AUTO-TRACKING-MIB.mib (14270 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF P-BRIDGE-MIB
ENTERASYS-MIB-NAMES IF-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Unsigned32
OBJECT-GROUP MODULE-COMPLIANCE EnabledStatus
etsysModules ifIndex

Defined Types

EtsysAutoTrackingPortEntry  
SEQUENCE    
  etsysAutoTrackingPortEnable EnabledStatus
  etsysAutoTrackingPortAuthenticationsAllowed Unsigned32
  etsysAutoTrackingPortAuthenticationsAllocated Unsigned32
  etsysAutoTrackingPortSessionTimeout Unsigned32
  etsysAutoTrackingPortIdleTimeout Unsigned32
  etsysAutoTrackingPortRadiusTimeoutProfileIndex Unsigned32
  etsysAutoTrackingPortRadiusRejectProfileIndex Unsigned32

Defined Values

etsysAutoTrackingMIB 1.3.6.1.4.1.5624.1.2.92
This MIB module defines a portion of the SNMP MIB under the Enterasys Networks enterprise OID pertaining to configuration of Auto Tracking on a device.
MODULE-IDENTITY    

etsysAutoTrackingBody 1.3.6.1.4.1.5624.1.2.92.2
OBJECT IDENTIFIER    

etsysAutoTrackingObjects 1.3.6.1.4.1.5624.1.2.92.2.1
OBJECT IDENTIFIER    

etsysAutoTrackingSystem 1.3.6.1.4.1.5624.1.2.92.2.1.1
OBJECT IDENTIFIER    

etsysAutoTrackingPort 1.3.6.1.4.1.5624.1.2.92.2.1.2
OBJECT IDENTIFIER    

etsysAutoTrackingSystemEnable 1.3.6.1.4.1.5624.1.2.92.2.1.1.1
When enabled(1), all objects in this MIB are fully active. When disabled(2), this object overrides all other object settings in this MIB without affecting their values.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

etsysAutoTrackingSystemAccountEnable 1.3.6.1.4.1.5624.1.2.92.2.1.1.2
When enabled(1), RADIUS accounting start, interim and stop frames are sent to the configured RADIUS server(s). When disabled(2), accounting packets are not sent to the RADIUS server.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

etsysAutoTrackingPortTable 1.3.6.1.4.1.5624.1.2.92.2.1.2.1
A table containing configuration objects for each auto tracking port. The configuration for each port in this table must be non-volatile.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EtsysAutoTrackingPortEntry

etsysAutoTrackingPortEntry 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1
Each conceptual row provides control over all of the initial values used by each auto authenticated MAC on this port. Subsequent changes to rows in this table, except where noted, have no effect on existing auto tracking sessions on this port.
Status: current Access: not-accessible
OBJECT-TYPE    
  EtsysAutoTrackingPortEntry  

etsysAutoTrackingPortEnable 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.1
When set to enabled(1), a platform dependent triggering mechanism initiates auto tracking for sessions on this port. When disabled(2), auto tracking is disabled and all currently auto tracking sessions or those in the process of auto tracking on this port are terminated.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

etsysAutoTrackingPortAuthenticationsAllowed 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.2
The maximum number of concurrent auto tracking sessions supported on this port on this module. The default value of this object is platform and resource dependent.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

etsysAutoTrackingPortAuthenticationsAllocated 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.3
The maximum number of auto tracking sessions permitted on this port on this module. This value must be non-zero and be less than or equal to the value of etsysAutoTrackingPortAuthenticationsAllowed. Setting this object to a value less than the current number of auto tracking sessions on this port prevents further auto tracking sessions, but has no affect on the current sessions.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

etsysAutoTrackingPortSessionTimeout 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.4
The maximum number of seconds an auto tracking session may last before termination of the session. A value of zero indicates that the global etsysMultiAuthSessionTimeout value will be used.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0 | 1..65535  

etsysAutoTrackingPortIdleTimeout 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.5
The maximum number of consecutive seconds an auto tracking session may be idle before termination of the session. A value of zero indicates that the global etsysMultiAuthSessionTimeout value will be used.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0 | 1..65535  

etsysAutoTrackingPortRadiusTimeoutProfileIndex 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.6
The policy profile index to be used by the auto-tracking provisioning agent if a complete RADIUS server timeout occurs. This policy profile index will only be used if the auto-tracking provisioning agent is the highest precedent multiauth provisioning agent to provision the session. Auto-tracking has the lowest precedence by default. The value will be overwritten by the policy profile index in etsysAutoTrackingPortRadiusRejectProfileIndex if both a rejection and a complete timeout occur. A value of (0) indicates that no policy profile index is configured for complete RADIUS server timeouts.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0 | 1..65535  

etsysAutoTrackingPortRadiusRejectProfileIndex 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.7
The policy profile index to be used by the auto-tracking provisioning agent if a complete RADIUS server timeout occurs. This policy profile index will only be used if the auto-tracking provisioning agent is the highest precedent multiauth provisioning agent to provision the session. Auto-tracking has the lowest precedence by default. The value will not be overwritten by the policy profile index in etsysAutoTrackingPortRadiusTimeoutProfileIndex if both a rejection and a complete timeout occur. A value of (0) indicates that no policy profile index is configured for complete RADIUS server timeouts.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0 | 1..65535  

etsysAutoTrackingConformance 1.3.6.1.4.1.5624.1.2.92.3
OBJECT IDENTIFIER    

etsysAutoTrackingGroups 1.3.6.1.4.1.5624.1.2.92.3.1
OBJECT IDENTIFIER    

etsysAutoTrackingCompliances 1.3.6.1.4.1.5624.1.2.92.3.2
OBJECT IDENTIFIER    

etsysAutoTrackingSystemGroup 1.3.6.1.4.1.5624.1.2.92.3.1.1
Global object controlling this feature. Global objects that affect how the credentials are presented to the authentication server.
Status: deprecated Access: read-write
OBJECT-GROUP    

etsysAutoTrackingPortGroup 1.3.6.1.4.1.5624.1.2.92.3.1.2
Objects describing the Auto Tracking variables for each port.
Status: deprecated Access: read-write
OBJECT-GROUP    

etsysAutoTrackingSystemGroup2 1.3.6.1.4.1.5624.1.2.92.3.1.3
Global object controlling this feature. Global objects that affect how the credentials are presented to the authentication server.
Status: current Access: read-write
OBJECT-GROUP    

etsysAutoTrackingPortGroup2 1.3.6.1.4.1.5624.1.2.92.3.1.4
Objects describing the Auto Tracking variables for each port.
Status: current Access: read-write
OBJECT-GROUP    

etsysAutoTrackingCompliance 1.3.6.1.4.1.5624.1.2.92.3.2.1
The compliance statement for devices that support Auto Tracking.
Status: deprecated Access: read-only
MODULE-COMPLIANCE    

etsysAutoTrackingCompliance2 1.3.6.1.4.1.5624.1.2.92.3.2.2
The compliance statement for devices that support Auto Tracking.
Status: current Access: read-only
MODULE-COMPLIANCE