EICON-MIB-RFC1315

File: EICON-MIB-RFC1315.mib (22129 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215

Imported symbols

Counter IpAddress enterprises
OBJECT-TYPE DisplayString TimeTicks
TRAP-TYPE

Defined Types

Index  
INTEGER    

DLCI  
INTEGER    

FrDlcmiEntry  
SEQUENCE    
  frDlcmiIfIndex Index
  frDlcmiState INTEGER
  frDlcmiAddress INTEGER
  frDlcmiAddressLen INTEGER
  frDlcmiPollingInterval INTEGER
  frDlcmiFullEnquiryInterval INTEGER
  frDlcmiErrorThreshold INTEGER
  frDlcmiMonitoredEvents INTEGER
  frDlcmiMaxSupportedVCs INTEGER
  frDlcmiMulticast INTEGER

FrCircuitEntry  
SEQUENCE    
  frCircuitIfIndex Index
  frCircuitDlci DLCI
  frCircuitState INTEGER
  frCircuitReceivedFECNs Counter
  frCircuitReceivedBECNs Counter
  frCircuitSentFrames Counter
  frCircuitSentOctets Counter
  frCircuitReceivedFrames Counter
  frCircuitReceivedOctets Counter
  frCircuitCreationTime TimeTicks
  frCircuitLastTimeChange TimeTicks
  frCircuitCommittedBurst INTEGER
  frCircuitExcessBurst INTEGER
  frCircuitThroughput INTEGER

FrErrEntry  
SEQUENCE    
  frErrIfIndex Index
  frErrType INTEGER
  frErrData OCTET STRING
  frErrTime TimeTicks

Defined Values

eicon 1.3.6.1.4.1.434
OBJECT IDENTIFIER    

management 1.3.6.1.4.1.434.2
OBJECT IDENTIFIER    

mibv2 1.3.6.1.4.1.434.2.2
OBJECT IDENTIFIER    

module 1.3.6.1.4.1.434.2.2.4
OBJECT IDENTIFIER    

frame-relay 1.3.6.1.4.1.434.2.2.4.32
OBJECT IDENTIFIER    

frDlcmiTable 1.3.6.1.4.1.434.2.2.4.32.1
The Parameters for the Data Link Connection Management Interface for the frame relay service on this interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrDlcmiEntry

frDlcmiEntry 1.3.6.1.4.1.434.2.2.4.32.1.1
The Parameters for a particular Data Link Con- nection Management Interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrDlcmiEntry  

frDlcmiIfIndex 1.3.6.1.4.1.434.2.2.4.32.1.1.1
The ifIndex value of the corresponding ifEn- try.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Index  

frDlcmiState 1.3.6.1.4.1.434.2.2.4.32.1.1.2
This variable states which Data Link Connec- tion Management scheme is active (and by impli- cation, what DLCI it uses) on the Frame Relay interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noLmiConfigured(1), lmiRev1(2), ansiT1-617-D(3), ansiT1-617-B(4)  

frDlcmiAddress 1.3.6.1.4.1.434.2.2.4.32.1.1.3
This variable states which address format is in use on the Frame Relay interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER q921(1), q922March90(2), q922November90(3), q922(4)  

frDlcmiAddressLen 1.3.6.1.4.1.434.2.2.4.32.1.1.4
This variable states which address length in octets. In the case of Q922 format, the length indicates the entire length of the address in- cluding the control portion.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER two-octets(2), three-octets(3), four-octets(4)  

frDlcmiPollingInterval 1.3.6.1.4.1.434.2.2.4.32.1.1.5
This is the number of seconds between succes- sive status enquiry messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

frDlcmiFullEnquiryInterval 1.3.6.1.4.1.434.2.2.4.32.1.1.6
Number of status enquiry intervals that pass before issuance of a full status enquiry mes- sage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

frDlcmiErrorThreshold 1.3.6.1.4.1.434.2.2.4.32.1.1.7
This is the maximum number of unanswered Status Enquiries the equipment shall accept be- fore declaring the interface down.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

frDlcmiMonitoredEvents 1.3.6.1.4.1.434.2.2.4.32.1.1.8
This is the number of status polling intervals over which the error threshold is counted. For example, if within 'MonitoredEvents' number of events the station receives 'ErrorThreshold' number of errors, the interface is marked as down.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

frDlcmiMaxSupportedVCs 1.3.6.1.4.1.434.2.2.4.32.1.1.9
The maximum number of Virtual Circuits allowed for this interface. Usually dictated by the Frame Relay network. In response to a SET, if a value less than zero or higher than the agent's maximal capability is configured, the agent should respond bad- Value
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

frDlcmiMulticast 1.3.6.1.4.1.434.2.2.4.32.1.1.10
This indicates whether the Frame Relay inter- face is using a multicast service.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nonBroadcast(1), broadcast(2)  

frCircuitTable 1.3.6.1.4.1.434.2.2.4.32.2
A table containing information about specific Data Link Connection Identifiers and corresponding virtual circuits.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrCircuitEntry

frCircuitEntry 1.3.6.1.4.1.434.2.2.4.32.2.1
The information regarding a single Data Link Connection Identifier.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrCircuitEntry  

frCircuitIfIndex 1.3.6.1.4.1.434.2.2.4.32.2.1.1
The ifIndex Value of the ifEntry this virtual circuit is layered onto.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Index  

frCircuitDlci 1.3.6.1.4.1.434.2.2.4.32.2.1.2
The Data Link Connection Identifier for this virtual circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DLCI  

frCircuitState 1.3.6.1.4.1.434.2.2.4.32.2.1.3
Indicates whether the particular virtual cir- cuit is operational. In the absence of a Data Link Connection Management Interface, virtual circuit entries (rows) may be created by set- ting virtual circuit state to 'active', or deleted by changing Circuit state to 'invalid'. Whether or not the row actually disappears is left to the implementation, so this object may actually read as 'invalid' for some arbitrary length of time. It is also legal to set the state of a virtual circuit to 'inactive' to temporarily disable a given circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER invalid(1), active(2), inactive(3)  

frCircuitReceivedFECNs 1.3.6.1.4.1.434.2.2.4.32.2.1.4
Number of frames received from the network in- dicating forward congestion since the virtual circuit was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

frCircuitReceivedBECNs 1.3.6.1.4.1.434.2.2.4.32.2.1.5
Number of frames received from the network in- dicating backward congestion since the virtual circuit was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

frCircuitSentFrames 1.3.6.1.4.1.434.2.2.4.32.2.1.6
The number of frames sent from this virtual circuit since it was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

frCircuitSentOctets 1.3.6.1.4.1.434.2.2.4.32.2.1.7
The number of octets sent from this virtual circuit since it was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

frCircuitReceivedFrames 1.3.6.1.4.1.434.2.2.4.32.2.1.8
Number of frames received over this virtual circuit since it was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

frCircuitReceivedOctets 1.3.6.1.4.1.434.2.2.4.32.2.1.9
Number of octets received over this virtual circuit since it was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

frCircuitCreationTime 1.3.6.1.4.1.434.2.2.4.32.2.1.10
The value of sysUpTime when the virtual cir- cuit was created, whether by the Data Link Con- nection Management Interface or by a SetRe- quest.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

frCircuitLastTimeChange 1.3.6.1.4.1.434.2.2.4.32.2.1.11
The value of sysUpTime when last there was a change in the virtual circuit state
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

frCircuitCommittedBurst 1.3.6.1.4.1.434.2.2.4.32.2.1.12
This variable indicates the maximum amount of data, in bits, that the network agrees to transfer under normal conditions, during the measurement interval.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

frCircuitExcessBurst 1.3.6.1.4.1.434.2.2.4.32.2.1.13
This variable indicates the maximum amount of uncommitted data bits that the network will at- tempt to deliver over the measurement interval. By default, if not configured when creating the entry, the Excess Information Burst Size is set to the value of ifSpeed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

frCircuitThroughput 1.3.6.1.4.1.434.2.2.4.32.2.1.14
Throughput is the average number of 'Frame Re- lay Information Field' bits transferred per second across a user network interface in one direction, measured over the measurement inter- val. If the configured committed burst rate and throughput are both non-zero, the measurement interval T=frCircuitCommittedBurst/frCircuitThroughput. If the configured committed burst rate and throughput are both zero, the measurement in- terval T=frCircuitExcessBurst/ifSpeed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

frErrTable 1.3.6.1.4.1.434.2.2.4.32.3
A table containing information about Errors on the Frame Relay interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrErrEntry

frErrEntry 1.3.6.1.4.1.434.2.2.4.32.3.1
The error information for a single frame relay interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrErrEntry  

frErrIfIndex 1.3.6.1.4.1.434.2.2.4.32.3.1.1
The ifIndex Value of the corresponding ifEn- try.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Index  

frErrType 1.3.6.1.4.1.434.2.2.4.32.3.1.2
The type of error that was last seen on this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknownError(1), receiveShort(2), receiveLong(3), illegalDLCI(4), unknownDLCI(5), dlcmiProtoErr(6), dlcmiUnknownIE(7), dlcmiSequenceErr(8), dlcmiUnknownRpt(9), noErrorSinceReset(10)  

frErrData 1.3.6.1.4.1.434.2.2.4.32.3.1.3
An octet string containing as much of the er- ror packet as possible. As a minimum, it must contain the Q.922 Address or as much as was delivered. It is desirable to include all in- formation up to the PDU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

frErrTime 1.3.6.1.4.1.434.2.2.4.32.3.1.4
The value of sysUpTime at which the error was detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

frame-relay-globals 1.3.6.1.4.1.434.2.2.4.32.4
OBJECT IDENTIFIER    

frTrapState 1.3.6.1.4.1.434.2.2.4.32.4.1
This variable indicates whether the system produces the frDLCIStatusChange trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

frDLCIStatusChange 1
This trap indicates that the indicated Virtual Circuit has changed state. It has either been created or invalidated, or has toggled between the active and inactive states.
TRAP-TYPE