EES-POWER-FERRO-MIB
File:
EES-POWER-FERRO-MIB.mib (49551 bytes)
Imported modules
Imported symbols
Defined Types
Status |
|
This integer value represents the operational or administrative
status of the system. Also used as alarm severity.
Depending on situation there may be limits on allowed values.
Operational values:
(1) unknown - status has not yet been defined
(2) normal - there are no activated alarms
(3) warning - OA, lowest level of 'abnormal' status
(4) minor - A3
(5) major - MA
(6) critical - CA, highest level of 'abnormal' status
Administrative values:
(7) unmanaged
(8) restricted
(9) testing
(10) disabled |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
unknown(1), normal(2), warning(3), minor(4), major(5), critical(6), unmanaged(7), restricted(8), testing(9), disabled(10) |
|
StatusChange |
|
Indicates 'activated' (1) or 'deactivated' (2) alarm events. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
activated(1), deactivated(2) |
|
PSBatteryEntry |
|
SEQUENCE |
|
|
|
|
psBatteryIndex |
Integer32 |
|
|
psBatteryCurrent |
Integer32 |
|
|
psBatteryName |
DisplayString |
|
PSTemperatureEntry |
|
SEQUENCE |
|
|
|
|
psTemperatureIndex |
Integer32 |
|
|
psTemperatureMeasurement |
Integer32 |
|
|
psTemperatureName |
DisplayString |
|
|
psTemperatureType |
INTEGER |
|
|
psTemperatureAlarmStatus |
INTEGER |
|
PSRectifierEntry |
|
SEQUENCE |
|
|
|
|
psRectifierIndex |
Integer32 |
|
|
psRectifierProductNumber |
DisplayString |
|
|
psRectifierHWVersion |
DisplayString |
|
|
psRectifierSWVersion |
DisplayString |
|
|
psRectifierSerialNumber |
DisplayString |
|
|
psRectifierCurrent |
Integer32 |
|
|
psRectifierIdent |
DisplayString |
|
|
psRectifierFail |
StatusChange |
|
PSDistributionLoadEntry |
|
SEQUENCE |
|
|
|
|
psDistributionLoadIndex |
Integer32 |
|
|
psDistributionLoadCurrent |
Integer32 |
|
|
psDistributionLoadName |
DisplayString |
|
PSDistributionGeneralEntry |
|
SEQUENCE |
|
|
|
|
psDistributionGeneralIndex |
Integer32 |
|
|
psDistributionGeneralCurrent |
Integer32 |
|
|
psDistributionGeneralName |
DisplayString |
|
PSConverterEntry |
|
SEQUENCE |
|
|
|
|
psConverterIndex |
Integer32 |
|
|
psConverterProductNumber |
DisplayString |
|
|
psConverterHWVersion |
DisplayString |
|
|
psConverterSWVersion |
DisplayString |
|
|
psConverterSerialNumber |
DisplayString |
|
|
psConverterCurrent |
Integer32 |
|
|
psConverterIdent |
DisplayString |
|
|
psConverterFail |
StatusChange |
|
EquipmentSignalTableEntry |
|
SEQUENCE |
|
|
|
|
psEquipmentSignalTableEntryIndex |
Integer32 |
|
|
psEquipmentSignalValue |
Integer32 |
|
PSSMDUHEntry |
|
SEQUENCE |
|
|
|
|
psSMDUHCurrentIndex |
Integer32 |
|
|
psSMDUHCurrent1 |
Integer32 |
|
|
psSMDUHCurrent2 |
Integer32 |
|
|
psSMDUHCurrent3 |
Integer32 |
|
|
psSMDUHCurrent4 |
Integer32 |
|
|
psSMDUHCurrent5 |
Integer32 |
|
|
psSMDUHCurrent6 |
Integer32 |
|
|
psSMDUHCurrent7 |
Integer32 |
|
|
psSMDUHCurrent8 |
Integer32 |
|
|
psSMDUHCurrent9 |
Integer32 |
|
|
psSMDUHCurrent10 |
Integer32 |
|
|
psSMDUHCurrent11 |
Integer32 |
|
|
psSMDUHCurrent12 |
Integer32 |
|
|
psSMDUHCurrent13 |
Integer32 |
|
|
psSMDUHCurrent14 |
Integer32 |
|
|
psSMDUHCurrent15 |
Integer32 |
|
|
psSMDUHCurrent16 |
Integer32 |
|
|
psSMDUHCurrent17 |
Integer32 |
|
|
psSMDUHCurrent18 |
Integer32 |
|
|
psSMDUHCurrent19 |
Integer32 |
|
|
psSMDUHCurrent20 |
Integer32 |
|
PsSMDUHPowerEntry |
|
SEQUENCE |
|
|
|
|
psSMDUHPowerIndex |
Integer32 |
|
|
psSMDUHPower1 |
Integer32 |
|
|
psSMDUHPower2 |
Integer32 |
|
|
psSMDUHPower3 |
Integer32 |
|
|
psSMDUHPower4 |
Integer32 |
|
|
psSMDUHPower5 |
Integer32 |
|
|
psSMDUHPower6 |
Integer32 |
|
|
psSMDUHPower7 |
Integer32 |
|
|
psSMDUHPower8 |
Integer32 |
|
|
psSMDUHPower9 |
Integer32 |
|
|
psSMDUHPower10 |
Integer32 |
|
|
psSMDUHPower11 |
Integer32 |
|
|
psSMDUHPower12 |
Integer32 |
|
|
psSMDUHPower13 |
Integer32 |
|
|
psSMDUHPower14 |
Integer32 |
|
|
psSMDUHPower15 |
Integer32 |
|
|
psSMDUHPower16 |
Integer32 |
|
|
psSMDUHPower17 |
Integer32 |
|
|
psSMDUHPower18 |
Integer32 |
|
|
psSMDUHPower19 |
Integer32 |
|
|
psSMDUHPower20 |
Integer32 |
|
PsSMDUHEnergyEntry |
|
SEQUENCE |
|
|
|
|
psSMDUHEnergyIndex |
Integer32 |
|
|
psSMDUHTotalEnergy1 |
Integer32 |
|
|
psSMDUHTotalEnergy2 |
Integer32 |
|
|
psSMDUHTotalEnergy3 |
Integer32 |
|
|
psSMDUHTotalEnergy4 |
Integer32 |
|
|
psSMDUHTotalEnergy5 |
Integer32 |
|
|
psSMDUHTotalEnergy6 |
Integer32 |
|
|
psSMDUHTotalEnergy7 |
Integer32 |
|
|
psSMDUHTotalEnergy8 |
Integer32 |
|
|
psSMDUHTotalEnergy9 |
Integer32 |
|
|
psSMDUHTotalEnergy10 |
Integer32 |
|
|
psSMDUHTotalEnergy11 |
Integer32 |
|
|
psSMDUHTotalEnergy12 |
Integer32 |
|
|
psSMDUHTotalEnergy13 |
Integer32 |
|
|
psSMDUHTotalEnergy14 |
Integer32 |
|
|
psSMDUHTotalEnergy15 |
Integer32 |
|
|
psSMDUHTotalEnergy16 |
Integer32 |
|
|
psSMDUHTotalEnergy17 |
Integer32 |
|
|
psSMDUHTotalEnergy18 |
Integer32 |
|
|
psSMDUHTotalEnergy19 |
Integer32 |
|
|
psSMDUHTotalEnergy20 |
Integer32 |
|
ActiveAlarmEntry |
|
SEQUENCE |
|
|
|
|
alarmIndex |
Counter32 |
|
|
alarmTime |
DateAndTime |
|
|
alarmStatusChange |
StatusChange |
|
|
alarmSeverity |
Status |
|
|
alarmDescription |
DisplayString |
|
|
alarmType |
Integer32 |
|
Defined Values
powerMIB |
1.3.6.1.4.1.6302.2.1 |
Emerson Energy Systems (EES) Power MIB, For SMDUH. |
MODULE-IDENTITY |
|
|
|
ees |
1.3.6.1.4.1.6302 |
OBJECT IDENTIFIER |
|
|
|
global |
1.3.6.1.4.1.6302.2 |
OBJECT IDENTIFIER |
|
|
|
ident |
1.3.6.1.4.1.6302.2.1.1 |
OBJECT IDENTIFIER |
|
|
|
identModel |
1.3.6.1.4.1.6302.2.1.1.2 |
The manufacturers model designation of the power system. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
identName |
1.3.6.1.4.1.6302.2.1.1.4 |
The name of the power plant. This object should be set by
the administrator. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
identSNMPCfgVer |
1.3.6.1.4.1.6302.2.1.1.5 |
The name of the power plant. This object should be set by
the administrator. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
system |
1.3.6.1.4.1.6302.2.1.2 |
OBJECT IDENTIFIER |
|
|
|
systemStatus |
1.3.6.1.4.1.6302.2.1.2.1 |
Status of the complete plant (highest alarm). One of
(1) unknown - status has not yet been defined
(2) normal - there are no activated alarms
(3) warning - OA, lowest level of 'abnormal' status
(4) minor - A3
(5) major - MA
(6) critical - CA, highest level of 'abnormal' status
(7) unmanaged
(8) restricted
(9) testing
(10) disabled |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Status |
|
|
systemVoltage |
1.3.6.1.4.1.6302.2.1.2.2 |
System voltage, stored as mV, including positive or negative
sign. The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
systemCurrent |
1.3.6.1.4.1.6302.2.1.2.3 |
System current, stored as mA, including positive or negative
sign. The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
systemUsedCapacity |
1.3.6.1.4.1.6302.2.1.2.4 |
Used capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psBattery |
1.3.6.1.4.1.6302.2.1.2.5 |
OBJECT IDENTIFIER |
|
|
|
psBatteryVoltage |
1.3.6.1.4.1.6302.2.1.2.5.1 |
Battery voltage, stored as mV, including positive or negative
sign. The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psTotalBatteryCurrent |
1.3.6.1.4.1.6302.2.1.2.5.2 |
Battery current, stored as mA, including positive or negative
sign. The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psBatteryCapacity |
1.3.6.1.4.1.6302.2.1.2.5.3 |
Calculated capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psBatteryNominalCapacity |
1.3.6.1.4.1.6302.2.1.2.5.4 |
nominal installed capacity, stored as mAh.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psBatteryEntry |
1.3.6.1.4.1.6302.2.1.2.5.5.1 |
Battery Measurement Table Entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PSBatteryEntry |
|
|
psBatteryIndex |
1.3.6.1.4.1.6302.2.1.2.5.5.1.1 |
Automatically generated index object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..16777215 |
|
psBatteryCurrent |
1.3.6.1.4.1.6302.2.1.2.5.5.1.2 |
Battery current in Amps. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psTemperature1 |
1.3.6.1.4.1.6302.2.1.2.7.1 |
The first route temperature, stored as 0.001 Celsius degree.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psTemperature2 |
1.3.6.1.4.1.6302.2.1.2.7.2 |
The second route temperature, stored as 0.001 Celsius degree.
The integer 2147483647 represents invalid value.. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psTemperatureEntry |
1.3.6.1.4.1.6302.2.1.2.7.3.1 |
Temperature Measurement Table Entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PSTemperatureEntry |
|
|
psTemperatureIndex |
1.3.6.1.4.1.6302.2.1.2.7.3.1.1 |
Temperature Probe Number |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..71 |
|
psTemperatureType |
1.3.6.1.4.1.6302.2.1.2.7.3.1.4 |
Temperature Probe Type |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), ambient(1), battery(2) |
|
psTemperatureAlarmStatus |
1.3.6.1.4.1.6302.2.1.2.7.3.1.5 |
Temperature Probe Alarm Status |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
high(0), low(1), fail(2), none(3) |
|
psStatusCommunication |
1.3.6.1.4.1.6302.2.1.2.8 |
The status of communication with the Power System. interrupt(3) indicates
some errors occurred between Power System and agent. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), normal(2), interrupt(3) |
|
psStatusBatteryMode |
1.3.6.1.4.1.6302.2.1.2.9 |
The status of battery modes,
FloatCharging(2),
ShortTest(3),
BoostChargingForTest(4),
ManualTesting(5),
PlanTesting(6),
ACFailTesting(7),
ACFail(8),
ManualBoostCharging(9),
AutoBoostCharging(10),
CyclicBoostCharging(11),
MasterBoostCharging(12),
MasterBateryTesting(13). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), floatCharging(2), shortTest(3), bcForTest(4), manualTesting(5), planTesting(6), acFailTesting(7), acFail(8), manualBC(9), autoBC(10), cyclicBC(11), masterBC(12), masterBT(13) |
|
psSMNumber |
1.3.6.1.4.1.6302.2.1.2.10 |
OBJECT IDENTIFIER |
|
|
|
psSMACNumber |
1.3.6.1.4.1.6302.2.1.2.10.1 |
The number of SM AC module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMBATNumber |
1.3.6.1.4.1.6302.2.1.2.10.2 |
The number of SM BAT module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMIONumber |
1.3.6.1.4.1.6302.2.1.2.10.3 |
The number of SM IO module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psRectifier |
1.3.6.1.4.1.6302.2.1.2.11 |
OBJECT IDENTIFIER |
|
|
|
numberOfInstalledRectifiers |
1.3.6.1.4.1.6302.2.1.2.11.1 |
number of rectifiers, stored as integer.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
numberOfRectifiersCommunicating |
1.3.6.1.4.1.6302.2.1.2.11.2 |
number of rectifiers communicating, stored as integer.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
rectifiersUsedCapacity |
1.3.6.1.4.1.6302.2.1.2.11.3 |
Used capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psRectifierTable |
1.3.6.1.4.1.6302.2.1.2.11.4 |
Table holding information about indivual rectifiers. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PSRectifierEntry |
|
psRectifierEntry |
1.3.6.1.4.1.6302.2.1.2.11.4.1 |
An entry (conceptual row) in the rectifierInfoTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PSRectifierEntry |
|
|
psRectifierIndex |
1.3.6.1.4.1.6302.2.1.2.11.4.1.1 |
Automatically generated index object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..16777215 |
|
psRectifierIdent |
1.3.6.1.4.1.6302.2.1.2.11.4.1.7 |
Rectifier physical location identifier. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
psRectifierFail |
1.3.6.1.4.1.6302.2.1.2.11.4.1.8 |
The type of alarm change. One of
(1) activated
(2) deactivated |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
StatusChange |
|
|
psTotalLoadCurrent |
1.3.6.1.4.1.6302.2.1.2.12.1 |
Total Load current, stored as integer.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psDistributionLoadEntry |
1.3.6.1.4.1.6302.2.1.2.12.2.1 |
Distribution Measurement Table Entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PSDistributionLoadEntry |
|
|
psDistributionLoadIndex |
1.3.6.1.4.1.6302.2.1.2.12.2.1.1 |
Automatically generated index object. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..268386303 |
|
psDistributionGeneralEntry |
1.3.6.1.4.1.6302.2.1.2.12.3.1 |
Distribution Measurement Table Entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PSDistributionGeneralEntry |
|
|
psConverter |
1.3.6.1.4.1.6302.2.1.2.13 |
OBJECT IDENTIFIER |
|
|
|
numberOfInstalledConverters |
1.3.6.1.4.1.6302.2.1.2.13.1 |
number of converters, stored as integer.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
numberOfConvertersCommunicating |
1.3.6.1.4.1.6302.2.1.2.13.2 |
number of converters communicating, stored as integer.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
convertersUsedCapacity |
1.3.6.1.4.1.6302.2.1.2.13.3 |
Used capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psConverterVoltage |
1.3.6.1.4.1.6302.2.1.2.13.4 |
Converter voltage in mV.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psTotalConverterCurrent |
1.3.6.1.4.1.6302.2.1.2.13.5 |
Total Converter current in Amps.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psConverterTable |
1.3.6.1.4.1.6302.2.1.2.13.6 |
Table holding information about indivual converters. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PSConverterEntry |
|
psConverterEntry |
1.3.6.1.4.1.6302.2.1.2.13.6.1 |
An entry (conceptual row) in the ConverterInfoTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PSConverterEntry |
|
|
psConverterIndex |
1.3.6.1.4.1.6302.2.1.2.13.6.1.1 |
Automatically generated index object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..100 |
|
psConverterIdent |
1.3.6.1.4.1.6302.2.1.2.13.6.1.7 |
Converter physical location identifier. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
psConverterFail |
1.3.6.1.4.1.6302.2.1.2.13.6.1.8 |
The type of alarm change. One of
(1) activated
(2) deactivated |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
StatusChange |
|
|
psControl |
1.3.6.1.4.1.6302.2.1.2.14 |
OBJECT IDENTIFIER |
|
|
|
controlBatteryTest |
1.3.6.1.4.1.6302.2.1.2.14.1 |
Control battery test, start(1), stop (0). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
controlRelay8 |
1.3.6.1.4.1.6302.2.1.2.14.2 |
Control relay8, close(1), open(0). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
controlRelay7 |
1.3.6.1.4.1.6302.2.1.2.14.3 |
Control relay7, close(1), open(0). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
controlRelay6 |
1.3.6.1.4.1.6302.2.1.2.14.4 |
Control relay6, close(1), open(0). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
controlRelayTest |
1.3.6.1.4.1.6302.2.1.2.14.5 |
Control Relay test, start(1), stop (0). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
equipmentSignalTableEntry |
1.3.6.1.4.1.6302.2.1.2.15.1 |
An entry (conceptual row) in the psEquipment Signal Table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EquipmentSignalTableEntry |
|
|
psEquipmentSignalTableEntryIndex |
1.3.6.1.4.1.6302.2.1.2.15.1.1 |
The unique sequence number of this equipment signal. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..268386303 |
|
numberOfInstalledSMDUH |
1.3.6.1.4.1.6302.2.1.2.16.1 |
number of SMDHU units, stored as integer.
The integer 2147483647 represents invalid value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHCurrentTable |
1.3.6.1.4.1.6302.2.1.2.16.10 |
Table holding information about SMDUH currents. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PSSMDUHEntry |
|
psSMDUHCurrentEntry |
1.3.6.1.4.1.6302.2.1.2.16.10.1 |
An entry (conceptual row) in the SMDUHTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PSSMDUHEntry |
|
|
psSMDUHCurrentIndex |
1.3.6.1.4.1.6302.2.1.2.16.10.1.1 |
Automatically generated index object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..64 |
|
psSMDUHCurrent1 |
1.3.6.1.4.1.6302.2.1.2.16.10.1.2 |
SMDUH Current 1. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHCurrent2 |
1.3.6.1.4.1.6302.2.1.2.16.10.1.3 |
SMDUH Current 2. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHCurrent3 |
1.3.6.1.4.1.6302.2.1.2.16.10.1.4 |
SMDUH Current 3. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHCurrent4 |
1.3.6.1.4.1.6302.2.1.2.16.10.1.5 |
SMDUH Current 4. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHCurrent5 |
1.3.6.1.4.1.6302.2.1.2.16.10.1.6 |
SMDUH Current 5. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHCurrent6 |
1.3.6.1.4.1.6302.2.1.2.16.10.1.7 |
SMDUH Current 6. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHCurrent7 |
1.3.6.1.4.1.6302.2.1.2.16.10.1.8 |
SMDUH Current 7. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHCurrent8 |
1.3.6.1.4.1.6302.2.1.2.16.10.1.9 |
SMDUH Current 8. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHCurrent9 |
1.3.6.1.4.1.6302.2.1.2.16.10.1.10 |
SMDUH Current 9. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPowerTable |
1.3.6.1.4.1.6302.2.1.2.17.1 |
Table holding information about SMDUH power. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PSSMDUHEntry |
|
psSMDUHPowerEntry |
1.3.6.1.4.1.6302.2.1.2.17.1.1 |
An entry (conceptual row) in the SMDUHPowerTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PSSMDUHEntry |
|
|
psSMDUHPowerIndex |
1.3.6.1.4.1.6302.2.1.2.17.1.1.1 |
Automatically generated index object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..64 |
|
psSMDUHPower1 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.2 |
SMDUH Power 1. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower2 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.3 |
SMDUH Power 2. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower3 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.4 |
SMDUH Power 3. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower4 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.5 |
SMDUH Power 4. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower5 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.6 |
SMDUH Power 5. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower6 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.7 |
SMDUH Power 6. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower7 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.8 |
SMDUH Power 7. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower8 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.9 |
SMDUH Power 8. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower9 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.10 |
SMDUH Power 9. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower10 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.11 |
SMDUH Power 10. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower11 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.12 |
SMDUH Power 11. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower12 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.13 |
SMDUH Power 12. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower13 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.14 |
SMDUH Power 13. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower14 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.15 |
SMDUH Power 14. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower15 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.16 |
SMDUH Power 15. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower16 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.17 |
SMDUH Power 16. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower17 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.18 |
SMDUH Power 17. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower18 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.19 |
SMDUH Power 18. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower19 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.20 |
SMDUH Power 19. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHPower20 |
1.3.6.1.4.1.6302.2.1.2.17.1.1.21 |
SMDUH Power 20. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
psSMDUHEnergyTable |
1.3.6.1.4.1.6302.2.1.2.18.1 |
Table holding information about SMDUH energy counters. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PSSMDUHEntry |
|
psSMDUHEnergyEntry |
1.3.6.1.4.1.6302.2.1.2.18.1.1 |
An entry (conceptual row) in the SMDUHEnergyTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PSSMDUHEntry |
|
|
psSMDUHEnergyIndex |
1.3.6.1.4.1.6302.2.1.2.18.1.1.1 |
Automatically generated index object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..64 |
|
alarmLastTrapNo |
1.3.6.1.4.1.6302.2.1.3 |
The sequence number of last submitted alarm trap,
also last row in alarmTrapTable. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alarmActiveAlarmTable |
1.3.6.1.4.1.6302.2.1.4 |
Table holding information about the currently active alarms. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
ActiveAlarmEntry |
|
activeAlarmEntry |
1.3.6.1.4.1.6302.2.1.4.1 |
An entry (conceptual row) in the alarmTrapTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ActiveAlarmEntry |
|
|
alarmIndex |
1.3.6.1.4.1.6302.2.1.4.1.1 |
The unique sequence number of this alarm trap. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alarmTime |
1.3.6.1.4.1.6302.2.1.4.1.2 |
Date and time when event occured (local time), including
timezone if supported by controller. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
alarmStatusChange |
1.3.6.1.4.1.6302.2.1.4.1.3 |
The type of alarm change. One of
(1) activated
(2) deactivated |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
StatusChange |
|
|
alarmSeverity |
1.3.6.1.4.1.6302.2.1.4.1.4 |
The severity of the alarm. One of
(3) warning - OA, lowest level of alarm severity
(4) minor - A3
(5) major - MA
(6) critical - CA, highest level of alarm severity |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Status |
|
|
alarmType |
1.3.6.1.4.1.6302.2.1.4.1.6 |
Alarm type, i.e. an integer specifying the type of alarm. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
alarmTrap |
1.3.6.1.4.1.6302.2.1.5.1 |
An alarm trap is sent when an alarm occurs (activated) or
returns to normal state (deactivated). Alarm traps are logged
in alarmTrapTable. Variables in this trap:
* alarmIndex - The unique sequence number of this alarm trap.
* alarmTime - Date and time when event occured (local time),
including timezone if supported by controller.
* alarmStatusChange - (1) activated or (2) deactivated.
* alarmSeverity - Integer describing the severity of the alarm.
* alarmDescription - Free-text description of alarm.
* alarmType - Integer indicating type of alarm. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
alarmActiveTrap |
1.3.6.1.4.1.6302.2.1.5.2 |
An alarm trap is sent when an alarm occurs (activated)
Variables in this trap
* alarmTime - Date and time when event occured (local time),
including timezone if supported by controller.
* alarmSeverity - Integer describing the severity of the alarm.
* alarmDescription - Free-text description of alarm.
* alarmType - Integer indicating type of alarm. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
alarmCeaseTrap |
1.3.6.1.4.1.6302.2.1.5.3 |
An alarm trap is sent when an alarm returns to normal state (clear, deactivated).
Variables in this trap:
* alarmTime - Date and time when event occured (local time),
including timezone if supported by controller.
* alarmSeverity - Integer describing the severity of the alarm.
* alarmDescription - Free-text description of alarm.
* alarmType - Integer indicating type of alarm. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|